Job Safety Analysis: Air Compressor Operation
Job Safety Analysis: Air Compressor Operation
Job Safety Analysis: Air Compressor Operation
Sequence of Basic
Potential Hazards Recommended Safe Job What Could Go Wrong Corrective Action
Job Steps
1. RT water Personal hazard Open inlet outlet Due to miss operation Proper supervision
circulation to valves of compressor of valves pressure required
be switched and switch on pump might buildup and
on lines will puncture
2. Switch on Personal hazard Open discharge valve Due to miss operation Proper supervision
compressor of compressor and of valves pressure required
switch on might buildup and
lines will puncture
3. Set required No hazard Set required pressure Wrong loading and Set based on user
pressure in the panel unloading values set requirement
setting
4. checking the Personal injury Compressor operating Hot zones are on Check for hot
compressor parameters to be compressor, so person surfaces and tag them
condition checked might experience as hot surface.
burns.
Page 1 of 2
JOB SAFETY ANALYSIS
Job: Air Compressor JSA/CTO2/ Mech/55 Prepared by: Reviewed by:
Operation K. Vivek Sagar K. Maheswara Reddy
Job Safety Analysis REV:00
Date:08/04/2015
Title of employee doing Supervisor: G.vijay Department: ESD Section: Utility(Acplant) Approved by:
job: Air Compressor kumar/Rakesh A Harothama Reddy
Operation Sharma/vivek sagar
/K.Sinivasa rao
Required / recommended PPE: Helmet with chin strip, Goggle, Cotton Hand gloves, and safety shoes.
Sequence of Basic
Potential Hazards Recommended Safe Job What Could Go Wrong Corrective Action
Job Steps
5. Switching on Personal injury Keep away from vent Pressurized air will vent is kept at a
the ADU line switch on mains vent and can injure a height and open to
and open the valve to person atmosphere.
ADU
Name
Signature
Date
Page 2 of 2