The document compares the specifications of various slickline wires and cables including their minimum breaking load, sheave diameter, weight, stretch, and corrosion resistance properties. It provides this information for wires of different diameters from manufacturers IPS API 9A, UTH API 9A, SUPA 70, SUPA 75, SUPA 80, and cable sizes 3/16" and 7/32". The corrosion resistance of the different wires is noted for environments containing H2S, CO2, chlorides, and combinations thereof.

Uploaded by

Refisal Bonnet
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (1 vote)
488 views2 pages

Slickline Wires

The document compares the specifications of various slickline wires and cables including their minimum breaking load, sheave diameter, weight, stretch, and corrosion resistance properties. It provides this information for wires of different diameters from manufacturers IPS API 9A, UTH API 9A, SUPA 70, SUPA 75, SUPA 80, and cable sizes 3/16" and 7/32". The corrosion resistance of the different wires is noted for environments containing H2S, CO2, chlorides, and combinations thereof.

Uploaded by

Refisal Bonnet
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

Slickline wires and cables

minimum
sheave weight stretch
breaking corrosion resistance
diameter lb/1000' 1"/100'/100lb
load

IPS API 9A 0.092" 1545 11 22.66 0.70 H2s + CO2 V. poor, may be used in low
H2S (2-3ppm)
0.108" 2110 13 31.23 0.51 Chlorides(brine salt) good - wire must be cleaned
after use to prevent pitting
0.125" 2830 15 41.84 0.38 H2S + CO2+chloride extremely poor due to the
presence of H2S+CO2

UTH API 9A 0.092" 2050 11 22.66 0.7 H2s + CO2 extremely poor may not be used
in any concentrations
0.108" 2730 13 31.23 0.51 Chlorides(brine salt) good - wire must be cleaned
after use to prevent pitting
0.125" 3665 15 41.84 0.38 H2S + CO2+chloride extremely poor due to the
presence of H2S+CO2

SUPA 70 0.092" 1600 11 23.29 0.79 H2s + CO2 excellent in all concentrations

0.108" 2100 13 32.1 0.58 Chlorides(brine salt) excellent

0.125" 2600 15 43 0.43 H2S + CO2+chloride may be used with caution risk
of stress corrosion cracking

SUPA 75 0.092" 1550 11 23.29 0.79 H2s + CO2 excellent in all concentrations

0.108" 2030 13 32.1 0.58 Chlorides(brine salt) excellent

0.125" 2560 15 43 0.43 H2S + CO2+chloride good superior to Supa 70

SUPA 80 0.092" 1625 11 23.29 0.79 H2s + CO2 excellent in all concentrations

0.108" 2175 13 32.1 0.58 Chlorides(brine salt) excellent

0.125" 2775 15 43 0.43 H2S + CO2+chloride good superior to Supa 75

3/16" Cable 0.187" 4960 12 71 galvanised

3/16" Cable 0.187" 4320 12 71 SUPA 70 /75


7/32" Cable 0.228" 6610 14 96 galvanised

7/32" Cable 0.228" 5842 14 96 SUPA 70 /75