10/23/2019 9:23 AM 1 / 38

Device Info
ACS580
Type
Model ACS580
Serial ASCC170x

Drive parameters

Index Name Value Unit Min Max Default

1. Actual values

1 Motor speed used 1332.02 rpm -30000.00 30000.00 0.00

2 Motor speed estimated 1332.02 rpm -30000.00 30000.00 0.00

3 Motor speed % 88.76 % -1000.00 1000.00 0.00

6 Output frequency 44.59 Hz -500.00 500.00 0.00

7 Motor current 300.67 A 0.00 30000.00 0.00

8 Motor current % of motor nom 76.2 % 0.0 1000.0 0.0

9 Motor current % of drive nom 51.5 % 0.0 1000.0 0.0

10 Motor torque 75.5 % -1600.0 1600.0 0.0

11 DC voltage 540.66 V 0.00 2000.00 0.00

13 Output voltage 362 V 0 2000 0

14 Output power 156.08 kW -32768.00 32767.00 0.00

15 Output power % of motor nom 71.34 % -300.00 300.00 0.00

16 Output power % of drive nom 0.00 % -300.00 300.00 0.00

17 Motor shaft power 151.93 kW -32768.00 32767.00 0.00

18 Inverter GWh counter 1 GWh 0 65535 0

19 Inverter MWh counter 563 MWh 0 1000 0

20 Inverter kWh counter 956 kWh 0 1000 0

24 Flux actual % 100 % 0 200 0

30 Nominal torque scale 1409.963 Nm 0.000 4000000.000 0.000

31 Ambient temperature 32 °C -40 120 0

50 Current hour kWh 138.28 kWh 0.00 1000000.00 0.00

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 2 / 38

Index Name Value Unit Min Max Default

51 Previous hour kWh 143.41 kWh 0.00 1000000.00 0.00

52 Current day kWh 1802.50 kWh 0.00 1000000.00 0.00

53 Previous day kWh 3736.95 kWh 0.00 1000000.00 0.00

61 Abs motor speed used 1332.01 rpm 0.00 30000.00 0.00

62 Abs motor speed % 88.80 % 0.00 1000.00 0.00

63 Abs output frequency 44.59 Hz 0.00 500.00 0.00

64 Abs motor torque 75.5 % 0.0 1600.0 0.0

65 Abs output power 156.08 kW 0.00 32767.00 0.00

66 Abs output power % motor nom 70.95 % 0.00 300.00 0.00

67 Abs output power % drive nom 0.00 % 0.00 300.00 0.00

68 Abs motor shaft power 150.61 kW 0.00 32767.00 0.00

3. Input references

1 Panel reference 1461.10 NoUnit -100000.00 100000.00 0.00

2 Panel reference remote 150.00 NoUnit -100000.00 100000.00 0.00

5 FB A reference 1 1332.15 NoUnit -100000.00 100000.00 0.00

6 FB A reference 2 150.00 NoUnit -100000.00 100000.00 0.00

9 EFB reference 1 0.00 NoUnit -30000.00 30000.00 0.00

10 EFB reference 2 0.00 NoUnit -30000.00 30000.00 0.00

4. Warnings and faults

1 Tripping fault 0x0000 NoUnit 0x0000 0xffff 0x0000

2 Active fault 2 0x0000 NoUnit 0x0000 0xffff 0x0000

3 Active fault 3 0x0000 NoUnit 0x0000 0xffff 0x0000

6 Active warning 1 0x0000 NoUnit 0x0000 0xffff 0x0000

7 Active warning 2 0x0000 NoUnit 0x0000 0xffff 0x0000

8 Active warning 3 0x0000 NoUnit 0x0000 0xffff 0x0000

11 Latest fault 0x7510 NoUnit 0x0000 0xffff 0x0000

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 3 / 38

Index Name Value Unit Min Max Default

12 2nd latest fault 0x3130 NoUnit 0x0000 0xffff 0x0000

13 3rd latest fault 0x0000 NoUnit 0x0000 0xffff 0x0000

16 Latest warning 0xafe1 NoUnit 0x0000 0xffff 0x0000

17 2nd latest warning 0xa3a2 NoUnit 0x0000 0xffff 0x0000

18 3rd latest warning 0xafe1 NoUnit 0x0000 0xffff 0x0000

5. Diagnostics

1 On-time counter 605 days 0 65535 0

2 Run-time counter 577 days 0 65535 0

4 Fan on-time counter 577 days 0 65535 0

10 Control board temperature 43 °C -100 300 0

11 Inverter temperature 48.1 % -40.0 160.0 0.0

22 Diagnostic word 3 0b1000 0000 0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

6. Control and status words

1 Main control word 0x047f NoUnit 0x0000 0xffff 0x0000

11 Main status word 0x1337 NoUnit 0x0000 0xffff 0x0000

16 Drive status word 1 0b0010 0100 0111 1101 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

17 Drive status word 2 0b1011 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

18 Start inhibit status word 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

19 Speed control status word 0b0010 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

20 Constant speed status word 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

21 Drive status word 3 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

30 MSW bit 11 selection Ext ctrl loc NoUnit Ext ctrl loc

31 MSW bit 12 selection Ext run enable NoUnit Ext run enable

32 MSW bit 13 selection False NoUnit False

33 MSW bit 14 selection False NoUnit False

7. System info

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 4 / 38

Index Name Value Unit Min Max Default

3 Drive rating id 2114 NoUnit 0 65535 Not selected

4 Firmware name ASCC4 NoUnit

5 Firmware version 1.70.3.0 NoUnit 0.00.0.0 255.255.255.255 0.00.0.0

6 Loading package name ASCL4 NoUnit

7 Loading package version 1.70.3.0 NoUnit 0.00.0.0 255.255.255.255 0.00.0.0

11 Cpu usage 62 % 0 100 0

25 Customization package name N/A_ NoUnit

26 Customization package version 0.00.0.0 NoUnit 0.00.0.0 255.255.255.255 0.00.0.0

10. Standard DI, RO

2 DI delayed status 0b0010 0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

3 DI force selection 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

4 DI forced data 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

21 RO status 0b0011 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

22 RO force selection 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

23 RO forced data 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

24 RO1 source Ready run NoUnit Ready run

25 RO1 ON delay 0.0 s 0.0 3000.0 0.0

26 RO1 OFF delay 0.0 s 0.0 3000.0 0.0

27 RO2 source Running NoUnit Running

28 RO2 ON delay 0.0 s 0.0 3000.0 0.0

29 RO2 OFF delay 0.0 s 0.0 3000.0 0.0

30 RO3 source Fault NoUnit Fault (-1)

31 RO3 ON delay 0.0 s 0.0 3000.0 0.0

32 RO3 OFF delay 0.0 s 0.0 3000.0 0.0

99 RO/DIO control word 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

101 RO1 toggle counter 208 NoUnit 0 4294967000 0

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 5 / 38

Index Name Value Unit Min Max Default

102 RO2 toggle counter 207 NoUnit 0 4294967000 0

103 RO3 toggle counter 24 NoUnit 0 4294967000 0

11. Standard DIO, FI, FO

25 DI6 configuration Digital input NoUnit 0 1 Digital input

38 Freq in 1 actual value 0 Hz 0 16000 0

39 Freq in 1 scaled value 0.000 NoUnit -32768.000 32767.000 0.000

42 Freq in 1 min 0 Hz 0 16000 0

43 Freq in 1 max 16000 Hz 0 16000 16000

44 Freq in 1 at scaled min 0.000 NoUnit -32768.000 32767.000 0.000

45 Freq in 1 at scaled max 1500.000 NoUnit -32768.000 32767.000 1500.000

12. Standard AI

2 AI force selection 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

3 AI supervision function No action NoUnit 0 4 No action

4 AI supervision selection 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

11 AI1 actual value 0.000 V 0.000 10.000 0.000

12 AI1 scaled value 0.000 NoUnit -32768.000 32767.000 0.000

13 AI1 forced value 0.000 V 0.000 10.000 0.000

15 AI1 unit selection V NoUnit 2 10 V

16 AI1 filter time 0.100 s 0.000 30.000 0.100

17 AI1 min 0.000 V 0.000 10.000 0.000

18 AI1 max 10.000 V 0.000 10.000 10.000

19 AI1 scaled at AI1 min 0.000 NoUnit -32768.000 32767.000 0.000

20 AI1 scaled at AI1 max 50.000 NoUnit -32768.000 32767.000 50.000

21 AI2 actual value -0.020 mA 0.000 20.000 0.000

22 AI2 scaled value 0.000 NoUnit -32768.000 32767.000 0.000

23 AI2 forced value 0.000 mA 0.000 20.000 0.000

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 6 / 38

Index Name Value Unit Min Max Default

25 AI2 unit selection mA NoUnit 2 10 mA

26 AI2 filter time 0.100 s 0.000 30.000 0.100

27 AI2 min 4.000 mA 0.000 20.000 4.000

28 AI2 max 20.000 mA 0.000 20.000 20.000

29 AI2 scaled at AI2 min 0.000 NoUnit -32768.000 32767.000 0.000

30 AI2 scaled at AI2 max 50.000 NoUnit -32768.000 32767.000 50.000

101 AI1 percent value 0.00 % 0.00 100.00 0.00

102 AI2 percent value 0.00 % 0.00 100.00 0.00

13. Standard AO

2 AO force selection 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

11 AO1 actual value 17.842 mA 0.000 22.000 0.000

12 AO1 source Output frequency NoUnit Output frequency

13 AO1 forced value 0.000 mA 0.000 22.000 0.000

15 AO1 unit selection mA NoUnit 2 10 mA

16 AO1 filter time 0.100 s 0.000 30.000 0.100

17 AO1 source min 0.0 NoUnit -32768.0 32767.0 0.0

18 AO1 source max 50.0 NoUnit -32768.0 32767.0 50.0

19 AO1 out at AO1 src min 0.000 mA 0.000 22.000 0.000

20 AO1 out at AO1 src max 20.000 mA 0.000 22.000 20.000

21 AO2 actual value 12.694 mA 0.000 22.000 0.000

22 AO2 source Motor current NoUnit Motor current

23 AO2 forced value 0.000 mA 0.000 22.000 0.000

26 AO2 filter time 0.100 s 0.000 30.000 0.100

27 AO2 source min 0.0 NoUnit -32768.0 32767.0 0.0

28 AO2 source max 474.0 NoUnit -32768.0 32767.0 30000.0

29 AO2 out at AO2 src min 0.000 mA 0.000 22.000 0.000

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 7 / 38

Index Name Value Unit Min Max Default

30 AO2 out at AO2 src max 20.000 mA 0.000 22.000 20.000

91 AO1 data storage 0.00 NoUnit -327.68 327.67 0.00

92 AO2 data storage 0.00 NoUnit -327.68 327.67 0.00

15. I/O extension module

1 Extension module type None NoUnit 0 4 None

2 Detected extension module None NoUnit 0 4 None

3 DI status 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

4 RO/DO status 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

5 RO/DO force selection 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

6 RO/DO forced data 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

7 RO4 source Not energized NoUnit Not energized

8 RO4 ON delay 0.0 s 0.0 3000.0 0.0

9 RO4 OFF delay 0.0 s 0.0 3000.0 0.0

10 RO5 source Not energized NoUnit Not energized

11 RO5 ON delay 0.0 s 0.0 3000.0 0.0

12 RO5 OFF delay 0.0 s 0.0 3000.0 0.0

22 DO1 configuration Digital output NoUnit 0 2 Digital output

23 DO1 source Not energized NoUnit Not energized

24 DO1 ON delay 0.0 s 0.0 3000.0 0.0

25 DO1 OFF delay 0.0 s 0.0 3000.0 0.0

32 Freq out 1 actual value 0 Hz 0 16000 0

33 Freq out 1 source Motor speed used NoUnit Motor speed used

34 Freq out 1 src min 0.000 NoUnit -32768.000 32767.000 0.000

35 Freq out 1 src max 1500.000 NoUnit -32768.000 32767.000 1500.000

36 Freq out 1 at src min 0 Hz 0 16000 0

37 Freq out 1 at src max 16000 Hz 0 16000 16000

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 8 / 38

Index Name Value Unit Min Max Default

19. Operation mode

1 Actual operation mode Speed NoUnit 1 20 Speed

11 Ext1/Ext2 selection EXT1 NoUnit EXT1

12 Ext1 control mode Speed NoUnit 1 5 Speed

14 Ext2 control mode Speed NoUnit 1 5 Speed

16 Local control mode Speed NoUnit 0 1 Speed

17 Local control disable No NoUnit 0 1 No

20. Start/stop/direction

1 Ext1 commands Fieldbus A NoUnit 0 14 In1 Start; In2 Dir

2 Ext1 start trigger type Level NoUnit 0 1 Level

3 Ext1 in1 source DI1 NoUnit DI1

4 Ext1 in2 source DI2 NoUnit DI2

5 Ext1 in3 source Not selected NoUnit Not selected

6 Ext2 commands Not selected NoUnit 0 14 Not selected

7 Ext2 start trigger type Level NoUnit 0 1 Level

8 Ext2 in1 source Not selected NoUnit Not selected

9 Ext2 in2 source Not selected NoUnit Not selected

10 Ext2 in3 source Not selected NoUnit Not selected

11 Run enable stop mode Coast NoUnit 0 2 Coast

12 Run enable 1 source Selected NoUnit Selected

19 Enable start command Selected NoUnit Selected

21 Direction Request NoUnit 0 2 Request

22 Enable to rotate Selected NoUnit Selected

25 Jogging enable Not selected NoUnit Not selected

26 Jogging 1 start source Not selected NoUnit Not selected

27 Jogging 2 start source Not selected NoUnit Not selected

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 9 / 38

Index Name Value Unit Min Max Default

21. Start/stop mode

1 Vector start mode Automatic NoUnit 0 2 Automatic

2 Magnetization time 500 ms 0 10000 500

3 Stop mode Coast NoUnit 0 2 Coast

4 Emergency stop mode Ramp stop (Off1) NoUnit 0 2 Ramp stop (Off1)

5 Emergency stop source Inactive (true) NoUnit Inactive (true)

6 Zero speed limit 30.00 rpm 0.00 30000.00 30.00

7 Zero speed delay 0 ms 0 30000 0

8 DC current control 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

9 DC hold speed 5.00 rpm 0.00 1000.00 5.00

10 DC current reference 30.0 % 0.0 100.0 30.0

11 Post magnetization time 0 s 0 3000 0

14 Pre-heating input source Off NoUnit Off

16 Pre-heating current 0.0 % 0.0 30.0 0.0

18 Auto restart time 10.0 s 0.0 10.0 10.0

19 Scalar start mode Normal NoUnit 0 4 Normal

21 DC hold frequency 5.00 Hz 0.00 1000.00 5.00

22 Start delay 0.00 s 0.00 60.00 0.00

23 Smooth start Disabled NoUnit 0 2 Disabled

24 Smooth start current 50.0 % 10.0 100.0 50.0

25 Smooth start speed 10.0 % 2.0 100.0 10.0

26 Torque boost current 100.0 % 15.0 300.0 100.0

30 Speed compensated stop mode Off NoUnit 0 3 Off

31 Speed comp stop delay 0.00 s 0.00 1000.00 0.00

32 Speed comp stop threshold 10 % 0 100 10

22. Speed reference selection

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 10 / 38

Index Name Value Unit Min Max Default

1 Speed ref unlimited 1332.15 rpm -30000.00 30000.00 0.00

11 Ext1 speed ref1 FB A ref1 NoUnit AI1 scaled

12 Ext1 speed ref2 Zero NoUnit Zero

13 Ext1 speed function Ref1 NoUnit 0 5 Ref1

18 Ext2 speed ref1 Zero NoUnit Zero

19 Ext2 speed ref2 Zero NoUnit Zero

20 Ext2 speed function Ref1 NoUnit 0 5 Ref1

21 Constant speed function 0b0001 NoUnit 0b0000 0b1111 1111 1111 1111 0b0001

22 Constant speed sel1 DI3 NoUnit DI3

23 Constant speed sel2 DI4 NoUnit DI4

24 Constant speed sel3 Not selected NoUnit Not selected

26 Constant speed 1 300.00 rpm -30000.00 30000.00 300.00

27 Constant speed 2 600.00 rpm -30000.00 30000.00 600.00

28 Constant speed 3 900.00 rpm -30000.00 30000.00 900.00

29 Constant speed 4 1200.00 rpm -30000.00 30000.00 1200.00

30 Constant speed 5 1500.00 rpm -30000.00 30000.00 1500.00

31 Constant speed 6 2400.00 rpm -30000.00 30000.00 2400.00

32 Constant speed 7 3000.00 rpm -30000.00 30000.00 3000.00

41 Speed ref safe 0.00 rpm -30000.00 30000.00 0.00

42 Jogging 1 ref 0.00 rpm -30000.00 30000.00 0.00

43 Jogging 2 ref 0.00 rpm -30000.00 30000.00 0.00

51 Critical speed function 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

52 Critical speed 1 low 0.00 rpm -30000.00 30000.00 0.00

53 Critical speed 1 high 0.00 rpm -30000.00 30000.00 0.00

54 Critical speed 2 low 0.00 rpm -30000.00 30000.00 0.00

55 Critical speed 2 high 0.00 rpm -30000.00 30000.00 0.00

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 11 / 38

Index Name Value Unit Min Max Default

56 Critical speed 3 low 0.00 rpm -30000.00 30000.00 0.00

57 Critical speed 3 high 0.00 rpm -30000.00 30000.00 0.00

71 Motor potentiometer function Disabled NoUnit 0 3 Disabled

72 Motor potentiometer initial value 0.00 NoUnit -32768.00 32767.00 0.00

73 Motor potentiometer up source Not selected NoUnit Not selected

74 Motor potentiometer down source Not selected NoUnit Not selected

75 Motor potentiometer ramp time 40.0 s 0.0 3600.0 40.0

76 Motor potentiometer min value -50.00 NoUnit -32768.00 32767.00 -50.00

77 Motor potentiometer max value 50.00 NoUnit -32768.00 32767.00 50.00

80 Motor potentiometer ref act 0.00 NoUnit -32768.00 32767.00 0.00

86 Speed reference act 6 1332.15 rpm -30000.00 30000.00 0.00

87 Speed reference act 7 1332.15 rpm -30000.00 30000.00 0.00

23. Speed reference ramp

1 Speed ref ramp input 1332.67 rpm -30000.00 30000.00 0.00

2 Speed ref ramp output 1332.67 rpm -30000.00 30000.00 0.00

11 Ramp set selection DI5 NoUnit DI5

12 Acceleration time 1 120.000 s 0.000 1800.000 20.000

13 Deceleration time 1 120.000 s 0.000 1800.000 20.000

14 Acceleration time 2 60.000 s 0.000 1800.000 60.000

15 Deceleration time 2 60.000 s 0.000 1800.000 60.000

20 Acc time jogging 60.000 s 0.000 1800.000 60.000

21 Dec time jogging 60.000 s 0.000 1800.000 60.000

23 Emergency stop time 3.000 s 0.000 1800.000 3.000

28 Variable slope enable Off NoUnit 0 1 Off

29 Variable slope rate 50 ms 2 30000 50

32 Shape time 1 0.100 s 0.000 1800.000 0.100

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 12 / 38

Index Name Value Unit Min Max Default

33 Shape time 2 0.100 s 0.000 1800.000 0.100

24. Speed reference conditioning

1 Used speed reference 1332.60 rpm -30000.00 30000.00 0.00

2 Used speed feedback 1332.08 rpm -30000.00 30000.00 0.00

3 Speed error filtered 0.52 rpm -30000.00 30000.00 0.00

4 Speed error inverted -0.52 rpm -30000.00 30000.00 0.00

11 Speed correction 0.00 rpm -10000.00 10000.00 0.00

12 Speed error filter time 0 ms 0 10000 0

25. Speed control

1 Torque reference speed control 75.2 % -1600.0 1600.0 0.0

2 Speed proportional gain 10.00 NoUnit 0.00 250.00 10.00

3 Speed integration time 2.50 s 0.00 1000.00 2.50

4 Speed derivation time 0.000 s 0.000 10.000 0.000

5 Derivation filter time 8 ms 0 10000 8

6 Acc comp derivation time 0.00 s 0.00 1000.00 0.00

7 Acc comp filter time 8.0 ms 0.0 1000.0 8.0

15 Proportional gain em stop 10.00 NoUnit 1.00 250.00 10.00

53 Torque prop reference 0.1 % -30000.0 30000.0 0.0

54 Torque integral reference 75.1 % -30000.0 30000.0 0.0

55 Torque deriv reference 0.0 % -30000.0 30000.0 0.0

56 Torque acc compensation 0.0 % -30000.0 30000.0 0.0

26. Torque reference chain

1 Torque reference to TC 75.1 % -1600.0 1600.0 0.0

2 Torque reference used 75.2 % -1600.0 1600.0 0.0

8 Minimum torque ref -300.0 % -1000.0 0.0 -300.0

9 Maximum torque ref 300.0 % 0.0 1000.0 300.0

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 13 / 38

Index Name Value Unit Min Max Default

11 Torque ref1 source Zero NoUnit Zero

12 Torque ref2 source Zero NoUnit Zero

13 Torque ref1 function Ref1 NoUnit 0 5 Ref1

14 Torque ref1/2 selection Torque reference 1 NoUnit Torque reference 1

17 Torque ref filter time 0.000 s 0.000 30.000 0.000

18 Torque ramp up time 0.000 s 0.000 60.000 0.000

19 Torque ramp down time 0.000 s 0.000 60.000 0.000

21 Torque sel torque in Torque ref torq ctrl NoUnit Torque ref torq ctrl

22 Torque sel speed in Torque ref speed ctrl NoUnit Torque ref speed ctrl

70 Torque reference act 1 0.0 % -1600.0 1600.0 0.0

71 Torque reference act 2 0.0 % -1600.0 1600.0 0.0

72 Torque reference act 3 0.0 % -1600.0 1600.0 0.0

73 Torque reference act 4 0.0 % -1600.0 1600.0 0.0

74 Torque ref ramp out 0.0 % -1600.0 1600.0 0.0

75 Torque reference act 5 75.2 % -1600.0 1600.0 0.0

28. Frequency reference chain

1 Frequency ref ramp input 0.00 Hz -500.00 500.00 0.00

2 Frequency ref ramp output 0.00 Hz -500.00 500.00 0.00

11 Ext1 frequency ref1 FB A ref1 NoUnit AI1 scaled

12 Ext1 frequency ref2 Zero NoUnit Zero

13 Ext1 frequency function Ref1 NoUnit 0 5 Ref1

15 Ext2 frequency ref1 Zero NoUnit Zero

16 Ext2 frequency ref2 Zero NoUnit Zero

17 Ext2 frequency function Ref1 NoUnit 0 5 Ref1

21 Constant frequency function 0b0001 NoUnit 0b0000 0b1111 1111 1111 1111 0b0001

22 Constant frequency sel1 DI3 NoUnit DI3

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 14 / 38

Index Name Value Unit Min Max Default

23 Constant frequency sel2 DI4 NoUnit DI4

24 Constant frequency sel3 Not selected NoUnit Not selected

26 Constant frequency 1 5.00 Hz -500.00 500.00 5.00

27 Constant frequency 2 10.00 Hz -500.00 500.00 10.00

28 Constant frequency 3 15.00 Hz -500.00 500.00 15.00

29 Constant frequency 4 20.00 Hz -500.00 500.00 20.00

30 Constant frequency 5 25.00 Hz -500.00 500.00 25.00

31 Constant frequency 6 40.00 Hz -500.00 500.00 40.00

32 Constant frequency 7 50.00 Hz -500.00 500.00 50.00

41 Frequency ref safe 0.00 Hz -500.00 500.00 0.00

51 Critical frequency function 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

52 Critical frequency 1 low 0.00 Hz -500.00 500.00 0.00

53 Critical frequency 1 high 0.00 Hz -500.00 500.00 0.00

54 Critical frequency 2 low 0.00 Hz -500.00 500.00 0.00

55 Critical frequency 2 high 0.00 Hz -500.00 500.00 0.00

56 Critical frequency 3 low 0.00 Hz -500.00 500.00 0.00

57 Critical frequency 3 high 0.00 Hz -500.00 500.00 0.00

71 Freq ramp set selection DI5 NoUnit DI5

72 Freq acceleration time 1 20.000 s 0.000 1800.000 20.000

73 Freq deceleration time 1 20.000 s 0.000 1800.000 20.000

74 Freq acceleration time 2 60.000 s 0.000 1800.000 60.000

75 Freq deceleration time 2 60.000 s 0.000 1800.000 60.000

76 Freq ramp in zero source Inactive NoUnit Inactive

82 Shape time 1 0.100 s 0.000 1800.000 0.100

83 Shape time 2 0.100 s 0.000 1800.000 0.100

92 Frequency ref act 3 0.00 Hz -500.00 500.00 0.00

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 15 / 38

Index Name Value Unit Min Max Default

96 Frequency ref act 7 0.00 Hz -500.00 500.00 0.00

97 Frequency ref unlimited 0.00 Hz -500.00 500.00 0.00

30. Limits

1 Limit word 1 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

2 Torque limit status 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

11 Minimum speed 150.00 rpm -30000.00 30000.00 -1500.00

12 Maximum speed 1500.00 rpm -30000.00 30000.00 1500.00

13 Minimum frequency 5.00 Hz -500.00 500.00 -50.00

14 Maximum frequency 50.00 Hz -500.00 500.00 50.00

17 Maximum current 474.00 A 0.00 730.00 730.00

18 Torq lim sel Torque limit set 1 NoUnit Torque limit set 1

19 Minimum torque 1 -300.0 % -1600.0 0.0 -300.0

20 Maximum torque 1 300.0 % 0.0 1600.0 300.0

21 Min torque 2 source Minimum torque 2 NoUnit Minimum torque 2

22 Max torque 2 source Maximum torque 2 NoUnit Maximum torque 2

23 Minimum torque 2 -300.0 % -1600.0 0.0 -300.0

24 Maximum torque 2 300.0 % 0.0 1600.0 300.0

26 Power motoring limit 300.00 % 0.00 600.00 300.00

27 Power generating limit -300.00 % -600.00 0.00 -300.00

30 Overvoltage control Enable NoUnit 0 1 Enable

31 Undervoltage control Enable NoUnit 0 1 Enable

31. Fault functions

1 External event 1 source Inactive (true) NoUnit Inactive (true)

2 External event 1 type Fault NoUnit 0 1 Fault

3 External event 2 source Inactive (true) NoUnit Inactive (true)

4 External event 2 type Fault NoUnit 0 1 Fault

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 16 / 38

Index Name Value Unit Min Max Default

5 External event 3 source Inactive (true) NoUnit Inactive (true)

6 External event 3 type Fault NoUnit 0 1 Fault

7 External event 4 source Inactive (true) NoUnit Inactive (true)

8 External event 4 type Fault NoUnit 0 1 Fault

9 External event 5 source Inactive (true) NoUnit Inactive (true)

10 External event 5 type Fault NoUnit 0 1 Fault

11 Fault reset selection Not selected NoUnit Not selected

12 Autoreset selection 0x0000 NoUnit 0x0000 0xffff 0x0000

13 Selectable fault 0x0000 NoUnit 0x0000 0xffff 0x0000

14 Number of trials 0 NoUnit 0 5 0

15 Total trials time 30.0 s 1.0 600.0 30.0

16 Delay time 0.0 s 0.0 120.0 0.0

19 Motor phase loss Fault NoUnit 0 1 Fault

20 Earth fault Fault NoUnit 0 2 Fault

21 Supply phase loss Fault NoUnit 0 1 Fault

22 STO indication run/stop Fault/Fault NoUnit 0 3 Fault/Fault

23 Wiring or earth fault Fault NoUnit 0 1 Fault

24 Stall function Fault NoUnit 0 2 No action

25 Stall current limit 200.0 % 0.0 1600.0 200.0

26 Stall speed limit 150.00 rpm 0.00 10000.00 150.00

27 Stall frequency limit 15.00 Hz 0.00 1000.00 15.00

28 Stall time 20 s 0 3600 20

30 Overspeed trip margin 500.00 rpm 0.00 10000.00 500.00

32 Emergency ramp supervision 0 % 0 300 0

33 Emergency ramp supervision delay 0 s 0 100 0

36 Aux fan fault bypass Off NoUnit 0 1 Off

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 17 / 38

Index Name Value Unit Min Max Default

32. Supervision

1 Supervision status 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

5 Supervision 1 function Disabled NoUnit 0 7 Disabled

6 Supervision 1 action No action NoUnit 0 3 No action

7 Supervision 1 signal Frequency NoUnit Frequency

8 Supervision 1 filter time 0.000 s 0.000 30.000 0.000

9 Supervision 1 low 0.00 NoUnit -21474836.00 21474836.00 0.00

10 Supervision 1 high 0.00 NoUnit -21474836.00 21474836.00 0.00

11 Supervision 1 hysteresis 0.00 NoUnit 0.00 100000.00 0.00

15 Supervision 2 function Disabled NoUnit 0 7 Disabled

16 Supervision 2 action No action NoUnit 0 3 No action

17 Supervision 2 signal Current NoUnit Current

18 Supervision 2 filter time 0.000 s 0.000 30.000 0.000

19 Supervision 2 low 0.00 NoUnit -21474836.00 21474836.00 0.00

20 Supervision 2 high 0.00 NoUnit -21474836.00 21474836.00 0.00

21 Supervision 2 hysteresis 0.00 NoUnit 0.00 100000.00 0.00

25 Supervision 3 function Disabled NoUnit 0 7 Disabled

26 Supervision 3 action No action NoUnit 0 3 No action

27 Supervision 3 signal Torque NoUnit Torque

28 Supervision 3 filter time 0.000 s 0.000 30.000 0.000

29 Supervision 3 low 0.00 NoUnit -21474836.00 21474836.00 0.00

30 Supervision 3 high 0.00 NoUnit -21474836.00 21474836.00 0.00

31 Supervision 3 hysteresis 0.00 NoUnit 0.00 100000.00 0.00

35 Supervision 4 function Disabled NoUnit 0 7 Disabled

36 Supervision 4 action No action NoUnit 0 3 No action

37 Supervision 4 signal Zero NoUnit Zero

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 18 / 38

Index Name Value Unit Min Max Default

38 Supervision 4 filter time 0.000 s 0.000 30.000 0.000

39 Supervision 4 low 0.00 NoUnit -21474836.00 21474836.00 0.00

40 Supervision 4 high 0.00 NoUnit -21474836.00 21474836.00 0.00

41 Supervision 4 hysteresis 0.00 NoUnit 0.00 100000.00 0.00

45 Supervision 5 function Disabled NoUnit 0 7 Disabled

46 Supervision 5 action No action NoUnit 0 3 No action

47 Supervision 5 signal Zero NoUnit Zero

48 Supervision 5 filter time 0.000 s 0.000 30.000 0.000

49 Supervision 5 low 0.00 NoUnit -21474836.00 21474836.00 0.00

50 Supervision 5 high 0.00 NoUnit -21474836.00 21474836.00 0.00

51 Supervision 5 hysteresis 0.00 NoUnit 0.00 100000.00 0.00

55 Supervision 6 function Disabled NoUnit 0 7 Disabled

56 Supervision 6 action No action NoUnit 0 3 No action

57 Supervision 6 signal Zero NoUnit Zero

58 Supervision 6 filter time 0.000 s 0.000 30.000 0.000

59 Supervision 6 low 0.00 NoUnit -21474836.00 21474836.00 0.00

60 Supervision 6 high 0.00 NoUnit -21474836.00 21474836.00 0.00

61 Supervision 6 hysteresis 0.00 NoUnit 0.00 100000.00 0.00

34. Timed functions

1 Timed functions status 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

2 Timer status 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

4 Season/exception day status 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

10 Timed functions enable Not selected NoUnit Not selected

11 Timer 1 configuration 0b0111 1000 0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0111 1000 0000

12 Timer 1 start time 00:00:00 NoUnit 00:00:00 N/A 00:00:00

13 Timer 1 duration 00 00:00 NoUnit 00 00:00 07 00:00 00 00:00

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 19 / 38

Index Name Value Unit Min Max Default

14 Timer 2 configuration 0b0111 1000 0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0111 1000 0000

15 Timer 2 start time 00:00:00 NoUnit 00:00:00 N/A 00:00:00

16 Timer 2 duration 00 00:00 NoUnit 00 00:00 07 00:00 00 00:00

17 Timer 3 configuration 0b0111 1000 0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0111 1000 0000

18 Timer 3 start time 00:00:00 NoUnit 00:00:00 N/A 00:00:00

19 Timer 3 duration 00 00:00 NoUnit 00 00:00 07 00:00 00 00:00

20 Timer 4 configuration 0b0111 1000 0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0111 1000 0000

21 Timer 4 start time 00:00:00 NoUnit 00:00:00 N/A 00:00:00

22 Timer 4 duration 00 00:00 NoUnit 00 00:00 07 00:00 00 00:00

23 Timer 5 configuration 0b0111 1000 0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0111 1000 0000

24 Timer 5 start time 00:00:00 NoUnit 00:00:00 N/A 00:00:00

25 Timer 5 duration 00 00:00 NoUnit 00 00:00 07 00:00 00 00:00

26 Timer 6 configuration 0b0111 1000 0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0111 1000 0000

27 Timer 6 start time 00:00:00 NoUnit 00:00:00 N/A 00:00:00

28 Timer 6 duration 00 00:00 NoUnit 00 00:00 07 00:00 00 00:00

29 Timer 7 configuration 0b0111 1000 0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0111 1000 0000

30 Timer 7 start time 00:00:00 NoUnit 00:00:00 N/A 00:00:00

31 Timer 7 duration 00 00:00 NoUnit 00 00:00 07 00:00 00 00:00

32 Timer 8 configuration 0b0111 1000 0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0111 1000 0000

33 Timer 8 start time 00:00:00 NoUnit 00:00:00 N/A 00:00:00

34 Timer 8 duration 00 00:00 NoUnit 00 00:00 07 00:00 00 00:00

35 Timer 9 configuration 0b0111 1000 0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0111 1000 0000

36 Timer 9 start time 00:00:00 NoUnit 00:00:00 N/A 00:00:00

37 Timer 9 duration 00 00:00 NoUnit 00 00:00 07 00:00 00 00:00

38 Timer 10 configuration 0b0111 1000 0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0111 1000 0000

39 Timer 10 start time 00:00:00 NoUnit 00:00:00 N/A 00:00:00

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 20 / 38

Index Name Value Unit Min Max Default

40 Timer 10 duration 00 00:00 NoUnit 00 00:00 07 00:00 00 00:00

41 Timer 11 configuration 0b0111 1000 0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0111 1000 0000

42 Timer 11 start time 00:00:00 NoUnit 00:00:00 N/A 00:00:00

43 Timer 11 duration 00 00:00 NoUnit 00 00:00 07 00:00 00 00:00

44 Timer 12 configuration 0b0111 1000 0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0111 1000 0000

45 Timer 12 start time 00:00:00 NoUnit 00:00:00 N/A 00:00:00

46 Timer 12 duration 00 00:00 NoUnit 00 00:00 07 00:00 00 00:00

60 Season 1 start date 1.1 NoUnit n/a n/a 1.1

61 Season 2 start date 1.1 NoUnit n/a n/a 1.1

62 Season 3 start date 1.1 NoUnit n/a n/a 1.1

63 Season 4 start date 1.1 NoUnit n/a n/a 1.1

70 Number of active exceptions 3 NoUnit 0 16 3

71 Exception types 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

72 Exception 1 start 1.1 NoUnit n/a n/a 1.1

73 Exception 1 length 0 days 0 60 0

74 Exception 2 start 1.1 NoUnit n/a n/a 1.1

75 Exception 2 length 0 days 0 60 0

76 Exception 3 start 1.1 NoUnit n/a n/a 1.1

77 Exception 3 length 0 days 0 60 0

78 Exception day 4 1.1 NoUnit n/a n/a 1.1

79 Exception day 5 1.1 NoUnit n/a n/a 1.1

80 Exception day 6 1.1 NoUnit n/a n/a 1.1

81 Exception day 7 1.1 NoUnit n/a n/a 1.1

82 Exception day 8 1.1 NoUnit n/a n/a 1.1

83 Exception day 9 1.1 NoUnit n/a n/a 1.1

84 Exception day 10 1.1 NoUnit n/a n/a 1.1

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 21 / 38

Index Name Value Unit Min Max Default

85 Exception day 11 1.1 NoUnit n/a n/a 1.1

86 Exception day 12 1.1 NoUnit n/a n/a 1.1

87 Exception day 13 1.1 NoUnit n/a n/a 1.1

88 Exception day 14 1.1 NoUnit n/a n/a 1.1

89 Exception day 15 1.1 NoUnit n/a n/a 1.1

90 Exception day 16 1.1 NoUnit n/a n/a 1.1

100 Timed function 1 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

101 Timed function 2 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

102 Timed function 3 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

110 Boost time function 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

111 Boost time activation source Off NoUnit Off

112 Boost time duration 00 00:00 NoUnit 00 00:00 07 00:00 00 00:00

35. Motor thermal protection

1 Motor estimated temperature 64 °C -60 1000 0

2 Measured temperature 1 65 °C -60 5000 0

3 Measured temperature 2 0 °C -60 5000 0

11 Temperature 1 source Estimated temperature NoUnit 0 22 Estimated temperature

12 Temperature 1 fault limit 130 °C -60 5000 130

13 Temperature 1 warning limit 110 °C -60 5000 110

14 Temperature 1 AI source Not selected NoUnit Not selected

21 Temperature 2 source Disabled NoUnit 0 22 Disabled

22 Temperature 2 fault limit 130 °C -60 5000 130

23 Temperature 2 warning limit 110 °C -60 5000 110

24 Temperature 2 AI source Not selected NoUnit Not selected

31 Safe motor temperature enable Off NoUnit 0 1 Off

50 Motor ambient temperature 20 °C -60 100 20

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 22 / 38

Index Name Value Unit Min Max Default

51 Motor load curve 100 % 50 150 100

52 Zero speed load 100 % 50 150 100

53 Break point 45.00 Hz 1.00 500.00 45.00

54 Motor nominal temperature rise 80 °C 0 300 80

55 Motor thermal time const 256 s 100 10000 256

36. Load analyzer

1 PVL signal source Output power NoUnit Output power

2 PVL filter time 2.00 s 0.00 120.00 2.00

6 AL2 signal source Motor torque NoUnit Motor torque

7 AL2 signal scaling 100.00 NoUnit 0.00 32767.00 100.00

9 Reset loggers Done NoUnit 0 3 Done

10 PVL peak value 211.53 NoUnit -32768.00 32767.00 0.00

11 PVL peak date 6/10/2019 NoUnit 1/1/1980 6/5/2159 1/1/1980

12 PVL peak time 00:47:55 NoUnit 00:00:00 N/A 00:00:00

13 PVL current at peak 361.42 A -32768.00 32767.00 0.00

14 PVL DC voltage at peak 543.00 V 0.00 2000.00 0.00

15 PVL speed at peak 1471.58 rpm -30000.00 30000.00 0.00

16 PVL reset date 1/1/1980 NoUnit 1/1/1980 6/5/2159 1/1/1980

17 PVL reset time 00:00:04 NoUnit 00:00:00 N/A 00:00:00

20 AL1 0 to 10% 0.00 % 0.00 100.00 0.00

21 AL1 10 to 20% 14.89 % 0.00 100.00 0.00

22 AL1 20 to 30% 20.59 % 0.00 100.00 0.00

23 AL1 30 to 40% 20.03 % 0.00 100.00 0.00

24 AL1 40 to 50% 43.12 % 0.00 100.00 0.00

25 AL1 50 to 60% 1.38 % 0.00 100.00 0.00

26 AL1 60 to 70% 0.00 % 0.00 100.00 0.00

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 23 / 38

Index Name Value Unit Min Max Default

27 AL1 70 to 80% 0.00 % 0.00 100.00 0.00

28 AL1 80 to 90% 0.00 % 0.00 100.00 0.00

29 AL1 over 90% 0.00 % 0.00 100.00 0.00

40 AL2 0 to 10% 1.82 % 0.00 100.00 0.00

41 AL2 10 to 20% 0.55 % 0.00 100.00 0.00

42 AL2 20 to 30% 20.58 % 0.00 100.00 0.00

43 AL2 30 to 40% 11.91 % 0.00 100.00 0.00

44 AL2 40 to 50% 2.07 % 0.00 100.00 0.00

45 AL2 50 to 60% 2.40 % 0.00 100.00 0.00

46 AL2 60 to 70% 9.15 % 0.00 100.00 0.00

47 AL2 70 to 80% 47.72 % 0.00 100.00 0.00

48 AL2 80 to 90% 3.78 % 0.00 100.00 0.00

49 AL2 over 90% 0.01 % 0.00 100.00 0.00

50 AL2 reset date 1/1/1980 NoUnit 1/1/1980 6/5/2159 1/1/1980

51 AL2 reset time 00:00:04 NoUnit 00:00:00 N/A 00:00:00

37. User load curve

1 ULC output status word 0b0010 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

2 ULC supervision signal Motor torque % NoUnit Motor torque %

3 ULC overload actions Disabled NoUnit 0 3 Disabled

4 ULC underload actions Disabled NoUnit 0 3 Disabled

11 ULC speed table point 1 150.0 rpm -30000.0 30000.0 150.0

12 ULC speed table point 2 750.0 rpm -30000.0 30000.0 750.0

13 ULC speed table point 3 1290.0 rpm -30000.0 30000.0 1290.0

14 ULC speed table point 4 1500.0 rpm -30000.0 30000.0 1500.0

15 ULC speed table point 5 1800.0 rpm -30000.0 30000.0 1800.0

16 ULC frequency table point 1 5.0 Hz -500.0 500.0 5.0

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 24 / 38

Index Name Value Unit Min Max Default

17 ULC frequency table point 2 25.0 Hz -500.0 500.0 25.0

18 ULC frequency table point 3 43.0 Hz -500.0 500.0 43.0

19 ULC frequency table point 4 50.0 Hz -500.0 500.0 50.0

20 ULC frequency table point 5 60.0 Hz -500.0 500.0 60.0

21 ULC underload point 1 10.0 % -1600.0 1600.0 10.0

22 ULC underload point 2 15.0 % -1600.0 1600.0 15.0

23 ULC underload point 3 25.0 % -1600.0 1600.0 25.0

24 ULC underload point 4 30.0 % -1600.0 1600.0 30.0

25 ULC underload point 5 30.0 % -1600.0 1600.0 30.0

31 ULC overload point 1 300.0 % -1600.0 1600.0 300.0

32 ULC overload point 2 300.0 % -1600.0 1600.0 300.0

33 ULC overload point 3 300.0 % -1600.0 1600.0 300.0

34 ULC overload point 4 300.0 % -1600.0 1600.0 300.0

35 ULC overload point 5 300.0 % -1600.0 1600.0 300.0

41 ULC overload timer 20.0 s 0.0 10000.0 20.0

42 ULC underload timer 20.0 s 0.0 10000.0 20.0

40. Process PID set 1

1 Process PID output actual 0.00 % -32768.00 32767.00 0.00

2 Process PID feedback actual 0.00 % -32768.00 32767.00 0.00

3 Process PID setpoint actual 0.00 % -32768.00 32767.00 0.00

4 Process PID deviation actual 0.00 % -32768.00 32767.00 0.00

6 Process PID status word 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

7 Process PID operation mode Off NoUnit 0 2 Off

8 Set 1 feedback 1 source AI2 percent NoUnit AI2 percent

9 Set 1 feedback 2 source Not selected NoUnit Not selected

10 Set 1 feedback function In1 NoUnit 0 11 In1

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 25 / 38

Index Name Value Unit Min Max Default

11 Set 1 feedback filter time 0.000 s 0.000 30.000 0.000

16 Set 1 setpoint 1 source AI1 percent NoUnit AI1 percent

17 Set 1 setpoint 2 source Not selected NoUnit Not selected

18 Set 1 setpoint function In1 NoUnit 0 11 In1

19 Set 1 internal setpoint sel1 Not selected NoUnit Not selected

20 Set 1 internal setpoint sel2 Not selected NoUnit Not selected

21 Set 1 internal setpoint 1 0.00 % -32768.00 32767.00 0.00

22 Set 1 internal setpoint 2 0.00 % -32768.00 32767.00 0.00

23 Set 1 internal setpoint 3 0.00 % -32768.00 32767.00 0.00

26 Set 1 setpoint min 0.00 NoUnit -32768.00 32767.00 0.00

27 Set 1 setpoint max 32767.00 NoUnit -32768.00 32767.00 32767.00

28 Set 1 setpoint increase time 0.0 s 0.0 1800.0 0.0

29 Set 1 setpoint decrease time 0.0 s 0.0 1800.0 0.0

30 Set 1 setpoint freeze enable Not selected NoUnit Not selected

31 Set 1 deviation inversion Not inverted (Ref - Fbk) NoUnit Not inverted (Ref - Fbk)

32 Set 1 gain 1.00 NoUnit 0.10 100.00 1.00

33 Set 1 integration time 60.0 s 0.0 9999.0 60.0

34 Set 1 derivation time 0.000 s 0.000 10.000 0.000

35 Set 1 derivation filter time 0.0 s 0.0 10.0 0.0

36 Set 1 output min 0.0 NoUnit -32768.0 32767.0 0.0

37 Set 1 output max 100.0 NoUnit -32768.0 32767.0 100.0

38 Set 1 output freeze enable Not selected NoUnit Not selected

43 Set 1 sleep level 0.0 NoUnit 0.0 32767.0 0.0

44 Set 1 sleep delay 60.0 s 0.0 3600.0 60.0

45 Set 1 sleep boost time 0.0 s 0.0 3600.0 0.0

46 Set 1 sleep boost step 0.0 % 0.0 32767.0 0.0

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 26 / 38

Index Name Value Unit Min Max Default

47 Set 1 wake-up deviation 0.00 % -32768.00 32767.00 0.00

48 Set 1 wake-up delay 0.50 s 0.00 60.00 0.50

49 Set 1 tracking mode Not selected NoUnit Not selected

50 Set 1 tracking ref selection Not selected NoUnit Not selected

57 PID set1/set2 selection PID set 1 NoUnit PID set 1

58 Set 1 increase prevention No NoUnit No

59 Set 1 decrease prevention No NoUnit No

62 PID internal setpoint actual 0.00 % -32768.00 32767.00 0.00

91 Feedback data storage 0.00 NoUnit -327.68 327.67 0.00

92 Setpoint data storage 0.00 NoUnit -327.68 327.67 0.00

41. Process PID set 2

8 Set 2 feedback 1 source AI2 percent NoUnit AI2 percent

9 Set 2 feedback 2 source Not selected NoUnit Not selected

10 Set 2 feedback function In1 NoUnit 0 11 In1

11 Set 2 feedback filter time 0.000 s 0.000 30.000 0.000

16 Set 2 setpoint 1 source AI1 percent NoUnit AI1 percent

17 Set 2 setpoint 2 source Not selected NoUnit Not selected

18 Set 2 setpoint function In1 NoUnit 0 11 In1

19 Set 2 internal setpoint sel1 Not selected NoUnit Not selected

20 Set 2 internal setpoint sel2 Not selected NoUnit Not selected

21 Set 2 internal setpoint 1 0.00 % -32768.00 32767.00 0.00

22 Set 2 internal setpoint 2 0.00 % -32768.00 32767.00 0.00

23 Set 2 internal setpoint 3 0.00 % -32768.00 32767.00 0.00

26 Set 2 setpoint min 0.00 NoUnit -32768.00 32767.00 0.00

27 Set 2 setpoint max 32767.00 NoUnit -32768.00 32767.00 32767.00

28 Set 2 setpoint increase time 0.0 s 0.0 1800.0 0.0

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 27 / 38

Index Name Value Unit Min Max Default

29 Set 2 setpoint decrease time 0.0 s 0.0 1800.0 0.0

30 Set 2 setpoint freeze enable Not selected NoUnit Not selected

31 Set 2 deviation inversion Not inverted (Ref - Fbk) NoUnit Not inverted (Ref - Fbk)

32 Set 2 gain 1.00 NoUnit 0.10 100.00 1.00

33 Set 2 integration time 60.0 s 0.0 9999.0 60.0

34 Set 2 derivation time 0.000 s 0.000 10.000 0.000

35 Set 2 derivation filter time 0.0 s 0.0 10.0 0.0

36 Set 2 output min 0.0 NoUnit -32768.0 32767.0 0.0

37 Set 2 output max 100.0 NoUnit -32768.0 32767.0 100.0

38 Set 2 output freeze enable Not selected NoUnit Not selected

43 Set 2 sleep level 0.0 NoUnit 0.0 32767.0 0.0

44 Set 2 sleep delay 60.0 s 0.0 3600.0 60.0

45 Set 2 sleep boost time 0.0 s 0.0 3600.0 0.0

46 Set 2 sleep boost step 0.0 % 0.0 32767.0 0.0

47 Set 2 wake-up deviation 0.00 % -32768.00 32767.00 0.00

48 Set 2 wake-up delay 0.50 s 0.00 60.00 0.50

49 Set 2 tracking mode Not selected NoUnit Not selected

50 Tracking ref sel Not selected NoUnit Not selected

58 Set 2 increase prevention No NoUnit No

59 Set 2 decrease prevention No NoUnit No

44. Mechanical brake control

1 Brake control status 0b0001 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

6 Brake control enable Not selected NoUnit Not selected

8 Brake open delay 0.00 s 0.00 5.00 0.00

13 Brake close delay 0.00 s 0.00 60.00 0.00

14 Brake close level 100.00 rpm 0.00 1000.00 100.00

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 28 / 38

Index Name Value Unit Min Max Default

45. Energy efficiency

1 Saved GW hours 1 GWh 0 65535 0

2 Saved MW hours 537 MWh 0 999 0

3 Saved kW hours 574.0 kWh 0.0 999.9 0.0

4 Saved energy 1537574.4 kWh 0.0 214748368.0 0.0

5 Saved money x1000 153 Local currency 0 4294967295 0

6 Saved money 757.42 Local currency 0.00 999.99 0.00

7 Saved amount 153757.44 Local currency 0.00 21474830.00 0.00

8 CO2 reduction in kilotons 0 metric kiloton 0 65535 0

9 CO2 reduction in tons 768.8 metric ton 0.0 999.9 0.0

10 Total saved CO2 768.8 metric ton 0.0 214748304.0 0.0

11 Energy optimizer Disable NoUnit 0 1 Disable

12 Energy tariff 1 0.100 Local currency 0.000 4294966.296 0.100

13 Energy tariff 2 0.200 Local currency 0.000 4294966.296 0.200

14 Tariff selection Energy tariff 1 NoUnit Energy tariff 1

18 CO2 conversion factor 0.500 tn/MWh 0.000 65.535 0.500

19 Comparison power 220.00 kW 0.00 10000000.00 0.00

21 Energy calculations reset Done NoUnit 0 1 Done

46. Monitoring/scaling settings

1 Speed scaling 1500.00 rpm 0.10 30000.00 1500.00

2 Frequency scaling 50.00 Hz 0.10 1000.00 50.00

3 Torque scaling 100.0 % 0.1 1000.0 100.0

4 Power scaling 1000.00 kW 0.10 30000.00 1000.00

5 Current scaling 10000 A 0 30000 10000

6 Speed ref zero scaling 0.00 rpm 0.00 30000.00 0.00

11 Filter time motor speed 500 ms 2 20000 500

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 29 / 38

Index Name Value Unit Min Max Default

12 Filter time output frequency 500 ms 2 20000 500

13 Filter time motor torque 100 ms 2 20000 100

14 Filter time power 100 ms 2 20000 100

21 At speed hysteresis 50.00 rpm 0.00 30000.00 50.00

22 At frequency hysteresis 2.00 Hz 0.00 1000.00 2.00

23 At torque hysteresis 5.0 % 0.0 300.0 5.0

31 Above speed limit 1500.00 rpm 0.00 30000.00 1500.00

32 Above frequency limit 50.00 Hz 0.00 1000.00 50.00

33 Above torque limit 300.0 % 0.0 1600.0 300.0

41 kWh pulse scaling 1.000 kWh 0.001 1000.000 1.000

47. Data storage

1 Data storage 1 real32 0.000 NoUnit -2147483.000 2147483.000 0.000

2 Data storage 2 real32 0.000 NoUnit -2147483.000 2147483.000 0.000

3 Data storage 3 real32 0.000 NoUnit -2147483.000 2147483.000 0.000

4 Data storage 4 real32 0.000 NoUnit -2147483.000 2147483.000 0.000

11 Data storage 1 int32 0 NoUnit -2147483648 2147483647 0

12 Data storage 2 int32 0 NoUnit -2147483648 2147483647 0

13 Data storage 3 int32 0 NoUnit -2147483648 2147483647 0

14 Data storage 4 int32 0 NoUnit -2147483648 2147483647 0

21 Data storage 1 int16 0 NoUnit -32768 32767 0

22 Data storage 2 int16 0 NoUnit -32768 32767 0

23 Data storage 3 int16 0 NoUnit -32768 32767 0

24 Data storage 4 int16 0 NoUnit -32768 32767 0

49. Panel port communication

1 Node ID number 1 NoUnit 1 32 1

3 Baud rate 115.2 kbps NoUnit 1 5 115.2 kbps

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 30 / 38

Index Name Value Unit Min Max Default

4 Communication loss time 10.0 s 0.3 3000.0 10.0

5 Communication loss action Fault NoUnit 0 3 Fault

6 Refresh settings Done NoUnit 0 1 Done

50. Fieldbus adapter (FBA)

1 FBA A enable Enable NoUnit 0 1 Disable

2 FBA A comm loss func Fault NoUnit 0 5 No action

3 FBA A comm loss t out 0.3 s 0.3 6553.5 0.3

4 FBA A ref1 type Speed or frequency NoUnit 0 5 Speed or frequency

5 FBA A ref2 type Speed or frequency NoUnit 0 5 Speed or frequency

6 FBA A SW sel Auto NoUnit 0 1 Auto

7 FBA A actual 1 type Speed or frequency NoUnit 0 5 Speed or frequency

8 FBA A actual 2 type Speed or frequency NoUnit 0 5 Speed or frequency

9 FBA A SW transparent source Not selected NoUnit Not selected

10 FBA A act1 transparent source Not selected NoUnit Not selected

11 FBA A act2 transparent source Not selected NoUnit Not selected

12 FBA A debug mode Disable NoUnit 0 1 Disable

13 FBA A control word 0.0.0.0 NoUnit 0.0.0.0 FF.FF.FF.FF 0.0.0.0

14 FBA A reference 1 0 NoUnit -2147483648 2147483647 0

15 FBA A reference 2 0 NoUnit -2147483648 2147483647 0

16 FBA A status word 0.0.0.0 NoUnit 0.0.0.0 FF.FF.FF.FF 0.0.0.0

17 FBA A actual value 1 0 NoUnit -2147483648 2147483647 0

18 FBA A actual value 2 0 NoUnit -2147483648 2147483647 0

51. FBA A settings

1 FBA A type PROFIBUS-DP NoUnit 0 47808 None

2 Node address 27 NoUnit 0 126 0

3 Baud rate 1500 NoUnit 0 12000 0

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 31 / 38

Index Name Value Unit Min Max Default

4 MSG type PPO4 NoUnit 0 10 Not detected

5 Profile ABB DRIVES NoUnit 0 3 PROFIdrive

6 T16 scale 99 NoUnit 0 65535 0

7 Emul mode Disabled NoUnit 0 4 Disabled

8 Map selection 32bit NoUnit 0 1 32bit

9 Module info Ok NoUnit 0 65535 Ok

10 FBA A Par10 0 NoUnit 0 65535 0

11 FBA A Par11 0 NoUnit 0 65535 0

12 FBA A Par12 0 NoUnit 0 65535 0

13 FBA A Par13 0 NoUnit 0 65535 0

14 FBA A Par14 0 NoUnit 0 65535 0

15 FBA A Par15 0 NoUnit 0 65535 0

16 FBA A Par16 0 NoUnit 0 65535 0

17 FBA A Par17 0 NoUnit 0 65535 0

18 FBA A Par18 0 NoUnit 0 65535 0

19 FBA A Par19 0 NoUnit 0 65535 0

20 FBA A Par20 0 NoUnit 0 65535 0

21 FBA A Par21 0 NoUnit 0 65535 0

22 FBA A Par22 0 NoUnit 0 65535 0

23 FBA A Par23 0 NoUnit 0 65535 0

24 FBA A Par24 0 NoUnit 0 65535 0

25 FBA A Par25 0 NoUnit 0 65535 0

26 FBA A Par26 0 NoUnit 0 65535 0

27 FBA A par refresh Done NoUnit 0 1 Done

28 FBA A par table ver 0x0201 NoUnit 0x0000 0xffff 0x0000

29 FBA A drive type code 610 NoUnit 0 65535 0

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 32 / 38

Index Name Value Unit Min Max Default

30 FBA A mapping file ver 3 NoUnit 0 65535 0

31 D2FBA A comm status On-line NoUnit 0 6 Not configured

32 FBA A comm SW ver 0x0000 NoUnit 0x0000 0xffff 0x0000

33 FBA A appl SW ver 0x0310 NoUnit 0x0000 0xffff 0x0000

52. FBA A data in

1 FBA A data in1 SW 16bit NoUnit None

2 FBA A data in2 Act1 16bit NoUnit None

3 FBA A data in3 1.7[16] NoUnit None

4 FBA A data in4 None NoUnit None

5 FBA A data in5 None NoUnit None

6 FBA A data in6 None NoUnit None

7 FBA A data in7 None NoUnit None

8 FBA A data in8 None NoUnit None

9 FBA A data in9 None NoUnit None

10 FBA A data in10 None NoUnit None

11 FBA A data in11 None NoUnit None

12 FBA A data in12 None NoUnit None

53. FBA A data out

1 FBA data out1 CW 16bit NoUnit None

2 FBA data out2 Ref1 16bit NoUnit None

3 FBA data out3 None NoUnit None

4 FBA data out4 None NoUnit None

5 FBA data out5 None NoUnit None

6 FBA data out6 None NoUnit None

7 FBA data out7 None NoUnit None

8 FBA data out8 None NoUnit None

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 33 / 38

Index Name Value Unit Min Max Default

9 FBA data out9 None NoUnit None

10 FBA data out10 None NoUnit None

11 FBA data out11 None NoUnit None

12 FBA data out12 None NoUnit None

58. Embedded fieldbus

1 Protocol enable None NoUnit 0 1 None

71. External PID1

1 External PID act value 0.00 % -32768.00 32767.00 0.00

2 Feedback act value 0.00 % -32768.00 32767.00 0.00

3 Setpoint act value 0.00 % -32768.00 32767.00 0.00

4 Deviation act value 0.00 % -32768.00 32767.00 0.00

6 PID status word 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

7 PID operation mode Off NoUnit 0 2 Off

8 Feedback 1 source AI2 percent NoUnit AI2 percent

11 Feedback filter time 0.000 s 0.000 30.000 0.000

14 Setpoint scaling 1500.00 NoUnit -32768.00 32767.00 1500.00

15 Output scaling 1500.00 NoUnit -32768.00 32767.00 1500.00

16 Setpoint 1 source AI1 percent NoUnit AI1 percent

19 Internal setpoint sel1 Not selected NoUnit Not selected

20 Internal setpoint sel2 Not selected NoUnit Not selected

21 Internal setpoint 1 0.00 % -32768.00 32767.00 0.00

22 Internal setpoint 2 0.00 % -32768.00 32767.00 0.00

23 Internal setpoint 3 0.00 % -32768.00 32767.00 0.00

26 Setpoint min 0.00 NoUnit -32768.00 32767.00 0.00

27 Setpoint max 32767.00 NoUnit -32768.00 32767.00 32767.00

31 Deviation inversion Not inverted (Ref - Fbk) NoUnit Not inverted (Ref - Fbk)

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 34 / 38

Index Name Value Unit Min Max Default

32 Gain 1.00 NoUnit 0.10 100.00 1.00

33 Integration time 60.0 s 0.0 9999.0 60.0

34 Derivation time 0.000 s 0.000 10.000 0.000

35 Derivation filter time 0.0 s 0.0 10.0 0.0

36 Output min -32768.0 NoUnit -32768.0 32767.0 -32768.0

37 Output max 32767.0 NoUnit -32768.0 32767.0 32767.0

38 Output freeze enable Not selected NoUnit Not selected

39 Deadband range 0.0 NoUnit 0.0 32767.0 0.0

40 Deadband delay 0.0 s 0.0 3600.0 0.0

58 Increase prevention No NoUnit No

59 Decrease prevention No NoUnit No

62 Internal setpoint actual 0.00 % -32768.00 32767.00 0.00

76. PFC configuration

1 PFC status 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

2 PFC system status PFC disabled NoUnit 0 801 PFC disabled

11 Pump/fan status 1 0b0010 0001 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

12 Pump/fan status 2 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

13 Pump/fan status 3 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

14 Pump/fan status 4 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

21 PFC configuration Off NoUnit 0 3 Off

25 Number of motors 1 NoUnit 1 4 1

26 Min number of motors allowed 1 NoUnit 0 4 1

27 Max number of motors allowed 1 NoUnit 1 4 1

30 Start speed 1 48 rpm 0 32767 1300

31 Start speed 2 48 rpm 0 32767 1300

32 Start speed 3 48 rpm 0 32767 1300

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 35 / 38

Index Name Value Unit Min Max Default

41 Stop speed 1 25 rpm 0 32767 800

42 Stop speed 2 25 rpm 0 32767 800

43 Stop speed 3 25 rpm 0 32767 800

55 Start delay 10.00 s 0.00 12600.00 10.00

56 Stop delay 10.00 s 0.00 12600.00 10.00

57 Speed hold on 0.00 s 0.00 1000.00 0.00

58 Speed hold off 0.00 s 0.00 1000.00 0.00

59 PFC contactor delay 0.50 s 0.20 600.00 0.50

60 PFC ramp acceleration time 1.00 s 0.00 1800.00 1.00

61 PFC ramp deceleration time 1.00 s 0.00 1800.00 1.00

70 Autochange Not selected NoUnit Not selected

71 Autochange interval 1.00 h 0.00 42949672.95 1.00

72 Maximum wear imbalance 10.00 h 0.00 1000000.00 10.00

73 Autochange level 100.0 % 0.0 300.0 100.0

74 Autochange auxiliary PFC Aux motors only NoUnit 0 1 Aux motors only

81 PFC 1 interlock Available. PFC motor is available NoUnit Available. PFC motor is availa

82 PFC 2 interlock Available. PFC motor is available NoUnit Available. PFC motor is availa

83 PFC 3 interlock Available. PFC motor is available NoUnit Available. PFC motor is availa

84 PFC 4 interlock Available. PFC motor is available NoUnit Available. PFC motor is availa

95 Regulator bypass control Disable NoUnit Disable

77. PFC maintenance and monitoring

10 PFC runtime change Done NoUnit 0 5 Done

11 Pump/fan 1 running time 0.00 h 0.00 42949672.95 0.00

12 Pump/fan 2 running time 0.00 h 0.00 42949672.95 0.00

13 Pump/fan 3 running time 0.00 h 0.00 42949672.95 0.00

14 Pump/fan 4 running time 0.00 h 0.00 42949672.95 0.00

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 36 / 38

Index Name Value Unit Min Max Default

95. HW configuration

1 Supply voltage Automatic / not selected NoUnit 0 6 Automatic / not selected

2 Adaptive voltage limits Enable NoUnit 0 1 Enable

3 Estimated AC supply voltage 408 V 0 65535 0

4 Control board supply Internal 24V NoUnit 0 1 Internal 24V

15 Special HW settings 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

20 HW options word 1 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

96. System

1 Language English NoUnit 0 3082 Not selected

2 Pass code NoUnit

3 Access level status 0b0001 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

4 Macro select Done NoUnit 0 32 Done

5 Macro active ABB standard NoUnit 0 32 ABB standard

6 Parameter restore Done NoUnit 0 34560 Done

7 Parameter save manually Done NoUnit 0 1 Done

8 Control board boot No action NoUnit 0 1 No action

10 User set status n/a NoUnit 0 11 n/a

11 User set save/load No action NoUnit 0 20 No action

12 User set I/O mode in1 Not selected NoUnit Not selected

13 User set I/O mode in2 Not selected NoUnit Not selected

16 Unit selection 0b0000 NoUnit 0b0000 0b1111 1111 1111 1111 0b0000

51 Clear fault and event logger 0 NoUnit 0 1 0

97. Motor control

1 Switching frequency reference 4 kHz NoUnit 2 12 4 kHz

2 Minimum switching frequency 1.5 kHz NoUnit 1 12 1.5 kHz

3 Slip gain 100 % 0 200 100

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 37 / 38

Index Name Value Unit Min Max Default

4 Voltage reserve -2 % -4 50 -2

5 Flux braking Disabled NoUnit 0 2 Disabled

9 Switching frequency mode Normal NoUnit 0 1 Normal

10 Signal injection Disabled NoUnit 0 4 Disabled

11 TR tuning 100 % 25 400 100

13 IR compensation 0.00 % 0.00 50.00 0.00

15 Motor model temperature adaptation Disabled NoUnit 0 1 Disabled

16 Stator temperature factor 50 % 0 200 50

17 Rotor temperature factor 100 % 0 200 100

18 Hexagonal field weakening Off NoUnit 0 1 Off

19 Hexagonal field weaking point 120.0 % 100.0 500.0 120.0

20 U/F Ratio Linear NoUnit 0 1 Linear

98. User motor parameters

1 User motor model mode Not selected NoUnit 0 1 Not selected

2 Rs user 0.02840 p.u. 0.00000 0.50000 0.00000

3 Rr user 0.00487 p.u. 0.00000 0.50000 0.00000

4 Lm user 2.86975 p.u. 0.00000 10.00000 0.00000

5 SigmaL user 0.20084 p.u. 0.00000 1.00000 0.00000

6 Ld user 0.00000 p.u. 0.00000 10.00000 0.00000

7 Lq user 0.00000 p.u. 0.00000 10.00000 0.00000

8 PM flux user 0.00000 p.u. 0.00000 2.00000 0.00000

9 Rs user SI 0.01660 Ohm 0.00000 100.00000 0.00000

10 Rr user SI 0.00285 Ohm 0.00000 100.00000 0.00000

11 Lm user SI 5.34 mH 0.00 100000.01 0.00

12 SigmaL user SI 0.37 mH 0.00 100000.01 0.00

13 Ld user SI 0.00 mH 0.00 100000.01 0.00

Drive composer pro v. 1.9.0.7


10/23/2019 9:23 AM 38 / 38

Index Name Value Unit Min Max Default

14 Lq user SI 0.00 mH 0.00 100000.01 0.00

99. Motor data

3 Motor type Asynchronous motor NoUnit 0 1 Asynchronous motor

4 Motor control mode Vector NoUnit 0 1 Scalar

6 Motor nominal current 395.0 A 97.5 1170.0 0.0

7 Motor nominal voltage 400.0 V 69.2 830.0 0.0

8 Motor nominal frequency 50.00 Hz 0.00 500.00 0.00

9 Motor nominal speed 1490 rpm 0 30000 0

10 Motor nominal power 220.00 kW 0.00 10000.00 0.00

11 Motor nominal cos φ 0.89 NoUnit 0.00 1.00 0.00

12 Motor nominal torque 0.000 Nm 0.000 4000000.000 0.000

13 ID run requested None NoUnit 0 6 None

14 Last ID run performed Normal NoUnit 0 6 None

15 Motor polepairs calculated 2 NoUnit 0 1000 0

16 Motor phase order UVW NoUnit 0 1 UVW

Drive composer pro v. 1.9.0.7