Flat Slab Design (SK)
Flat Slab Design (SK)
Flat Slab Design (SK)
Spreadsheet Limitation:
- Suitable for flat slab without Drop
- Both square and rectangular slab can be used
- Calculation based on 1 m strip
- Square RC pile provided
- fcu should always less than 40 N/mm2
k = 0.02
z = 0.98 d
= 0.95 d
As = 132.84 mm2/m
Suggested DA6(283)
Provide steel area 1341.00 mm2/m
k = 0.02
z = 0.98 d
= 0.95 d
As = 113.64 mm2/m
Suggested DA6(283)
Provide steel area 1341.00 mm2/m
First support
Max. -ve moment for column strip = +0.75(0.063FL)
(per m) = 6.01 kNm
k = 0.02
z = 0.98 d
= 0.95 d
As = 137.50 mm2/m
Suggested DA6 283
Provide steel area 1341.00
Interior support
Max. -ve moment for column strip = +0.75(0.055FL) 0
(per m) = 5.25 kNm
k = 0.02
z = 0.98 d
= 0.95 d
As = 120.04 mm2/m
Suggested DA6 283
Provide steel area 1341.00
DA7 TOP
DA6
+ + +
+ + +
2 DA6(283)
+ + +
2.00
plan typical slab section
plan
BRC mm2/m
DA10 785
DA9 636
DA8 503
DA7 385
DA6 283
DA5 196
BRC mm2/m
DA10 785
DA9 636
DA8 503
DA7 385
DA6 283
DA5 196
DA7 TOP
DA6
150
mm