100% found this document useful (1 vote)
435 views1 page

Report of Ultrasonic Flaw Detection Test of Weld Joint

This report summarizes an ultrasonic flaw detection test of a weld joint on a chlorine storage tank for Grasim Industries. The test inspected not less than 25% of all weld seams, including all T-joints, from the inside of the vessel using ultrasonic equipment with a 4MHz probe. No significant discontinuities were observed and the weld passed acceptance criteria for ASME Section VIII Division 1.

Uploaded by

kevin desai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
435 views1 page

Report of Ultrasonic Flaw Detection Test of Weld Joint

This report summarizes an ultrasonic flaw detection test of a weld joint on a chlorine storage tank for Grasim Industries. The test inspected not less than 25% of all weld seams, including all T-joints, from the inside of the vessel using ultrasonic equipment with a 4MHz probe. No significant discontinuities were observed and the weld passed acceptance criteria for ASME Section VIII Division 1.

Uploaded by

kevin desai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

REPORT OF ULTRASONIC FLAW DETECTION TEST OF WELD JOINT

Report No.: DIIS/2019-20/UFD/GRASIM-C/23 Dated-01/02/2020


Grasim Industries Limited,
1. Customer :
Vilayat, Dist: Bharuch, Gujarat
2. Description & ID number of Vessel : Chlorine Storage Tank No.:24T001C (1409C)
ASME Sec. VIII, Div. 1,Edition-2010 ED +
3. Vessel Design Code :
SMPV(U) RULES 1981
RAJ/UHDE/ABNL/770/2011 Rev 4
4. Vessel approved fabrication drawing :
Sheet No-1 of 3,Sheet No-2 of 3 and Sheet No-3 of 3
ART 4 of ASME SEC V (except that for thickness 2" or
5. Reference Standard : less, calibration blocks described in Fig. T-542.2.2 of
Article 5)
Not less than 25% of all weld seams including all T
6. Extent of test : joints, (from Inside of vessel)
(Annexure Attached, Page No.:1 to 7)
7. Date of test : 01/02/2020
8. Base material specification : SA 516 GR.70 (Shell & Dishend)
9. Surface Condition : As weld & As buffed.
10. Equipment : Ultrasonic Flaw Detector (DSC698KL)
11. Search Unit : EECI
Crystal Refraction Ref
Test type Frequency Wave Mode Range (mm)
Dimension angle Gain(db)

Angle 8 x 9 mm 70˚ 4 MHz Shear 100 33

Angle 8 x 9 mm 45˚ 4 MHz Shear 70 28

12. Scanning Sensitivity :


Ref + 6 dB
13. Couplant :
Paste (Oil + Grease)
14. Calibration Date :
MH/CL/1018V
15. Standard calibration block :
IIW V2 Block
16. Base calibration block As per Fig T-434.2.1 of Art 4 of ASME Sec V(38 mm)
17. Personnel Qualification : NDT – Level – II (UT)
18. Observation : No Significant discontinuity observed
19. Acceptance Criteria : Appendix – 12 of ASME SEC VIII DIV 1
20. NDT Result : Accepted.
EXAMINED BY (UT-LEVEL-II) REVIEWED BY

SIGNATURE

NAME Bhavik Prajapati HEMANT DESAI