Safety Procedures: Warning
Safety Procedures: Warning
Safety Procedures: Warning
CONDUIT
CONDUIT
INTERCOM SYSTEM
(must run wires in separate conduit) Call A - 1 B
(NEC Class 2) Call A - 2 B
10 Call B - 1 WB
Call B - 2 WB
VALANCE Valance Light Switch SMART Connect Wiring Communication -Twisted Pair
L2
BREAKERS
CONDUIT
CONDUIT
Neutral (Valance Lights) (14 AWG) Lights
C-13
(Customer
DISPENSER Earth ground (14 AWG) C-10 All Listen
Provided)
BREAKERS 10 (-) Speaker
(+) Option
M09259A001
FIELD CONDUIT
TB2-1 MODULE ASSEMBLY
M1
STP GND TB1-2 thru 8 STP4/MTR4 R 18 AWG STP4/MTR4 R
2 M2 TB2-2 thru 8
STPs
ATC (-) GY ATC (-) 18 AWG GY
ATC (+) OR ATC (+) 18 AWG OR ATC OPTION
STP
BREAKER Gilbarco STP Isolation Box #3 14 AWG
10 11 HTR - N W HTR - N W
L1 PA0287 HTR - H B HTR - H 14 AWG B HEATER OPTION
N SP - 3 Y SP - 3 18 AWG Y
TB1-1
L2 TB2-1 SP - 2 Y SP - 2 18 AWG
M1 GND TB1-2 thru 8 Y SPARE WIRES
SP - 1 SP - 1 18 AWG TO P3105 CRIND
STP
3 M2 J3105 CONTROL NODE (CCN) 3
TB2-2 thru 8
OR
Pump and CRIND Wiring Options 3 COLOR SCREEN CRIND
INTERFACE BOARD
STP Pump Only or Generic Pump
Gilbarco STP Isolation Box #4 J1109
for Generic
L1 PA0287 11 Pump Two-wire In (+) A19 W/B P100 J100
A-19 W/B NODE (PCN) 2
N Pump & CRIND for MOC or Generic CRIND
TB1-1 4 4
L2 B-9 B CRIND Two-wire Out B9 B M04493A009 M14947A001 (900)
To site TB2-1
M1 CRIND Two-wire In B19 Y M11961A003 (Omnia, MOC)
ground STP GND
TB1-2 thru 8
B-19 Y M11961A004 (Omnia, Generic)
2 electrode 4 M2 TB2-2 thru 8 M05547A00X (700)
Optional
L2
L1
N
Speaker A
Speaker A R
Speaker A B
Speaker B R (-)
FROM CONTRACTOR PROVIDED Speaker B
INTERCOM AND CALL SYSTEM B 5
CONDUIT
CONDUIT
CONDUIT
CONDUIT
Call A W
(+)
L1
(must run wires in separate conduit) J5 5 5 -1
GND
L2
N
Speaker B
(NEC Class 2) Call A W J5 5 5 -2
Call B BU J5 5 5 -3 Call Interface Cabling
Call B BU J5 5 5 -4
(-)
SMART Connect Communication - Twisted Pair
18 AWG J3432
VALANCE
Valance Light Switch 4 J-box supplied by installing contractor 4 18 AWG 2 SMART Connect
BREAKER 3 Communication
120 VAC HOT (Valance Lights) (14 AWG) C-2 To Valance - Twisted Pair
CONDUIT
6
CONDUIT
Neutral (Valance Lights) (14 AWG) C-13 Lights
(contractor
Earth ground (14 AWG) C-10 provided)
4
ELECTRONICS
BREAKER Main J-box M04493A013 (3-4 Grades)
A-2 B HOT (CD Module) M04493A014 (1-2 Grades)
MAIN CONDUIT
MTR2 L1 MTR2 L3 Y Spare 1 Y
Spare 1 module assemblies, refer to
MTR2 L2 MOTOR 3 MTR3 L1
refer to sheets 4 and 5. MDE-3804 Encore and Eclipse
Spare 2 Y Spare 2 Y
BREAKER MTR3 L2 Start-up/Service Manual.
CONDUIT
MTR3 L3
Spare 3 Y Spare 3 Y
MOTOR 3 3
MOTOR 4 MTR4 L1
BREAKER BREAKER
MTR3 L1 MTR4 L2 TO P3105
MTR4 L3 J3105 CCN 3 OR
MTR3 L2
COLOR SCREEN
3
220 VAC Single Phase Motor CRIND
Pump and CRIND Wiring Options
Connections INTERFACE
MOTOR 4
BREAKER 4 Pump Only or Generic Pump BOARD
J1109
MTR4 L1 Pump Two-wire Out (-) A9 TO P1109
W/R
for Generic
P100 J100
A-19 W/B Pump & CRIND for MOC or
Generic CRIND 4 4 M14947A001 (900)
B-9 M04493A013/14
B CRIND Two-wire Out B9 B M11961A003 (Omnia, MOC)
M11961A004 (Omnia, Generic)
CRIND Two-wire In B19 Y M05547A00X (700)
B-19 Y
L1
6
N
Red R
6 This Sheet Earth Ground Orange OR Field Wiring Diagram Encore® 500/700/900
LOAD CENTER 120/240 VAC Yellow Y Self-contained Pumps Wiring
SINGLE PHASE 50/60 HZ Encore 500 Self-contained Pump manufactured after No Connection Green GN (M07555 Power Supply Only)
November 2004 with J-box and M07555 Power Supply. Connection Blue BU
Single phase 115/120 VAC and 220/230 VAC. Violet V
120/240/380 VAC
Crimp Connector Sheet 3 of 11
For motor connections, refer to sheet 4 and 5. Gray GY
White W
White Black WB 11/18 FE-363U
White Red WR
GRN-18GA 3
GRN-18GA 3
W-18GA 2
B-18GA 1
W-18GA 2
B-18GA 1
THREE PHASE
Y-18GA
Y-18GA
Y-18GA
Y-18GA
Y-18GA
Y-18GA
Y-18GA
Y-18GA
SINGLE PHASE MOTOR CONNECTION
MOTOR CONNECTION 220 VAC
115/120VAC Use STP motor connections Notes: 1 ) Connections made in field.
Use STP motor connections
STP-1
STP-3
STP-4
A13
A10
STP-2
2 ) Motors must rotate counterclockwise.
A2
STP-4
STP-2
STP-1
STP-3
Y-18GA LEAD 2
A13
A10
A2
See Note 1 Y-18GA LEAD 4
Y-18GA LEAD 3
Y-18GA LEAD 5
BR-16GA Y-18GA LEAD 1
R-18GA See Note 1 Y-18GA LEAD 6
R-18GA See Note 1 R-18GA
V-16GA R-18GA
Y-16GA
B-16GA Y-18GA LEAD 2
MOTOR 4 (Z POSITION)
BU-16GA Y-18GA LEAD 4
Y-18GA LEAD 3
See Note 1 MOTOR 4 (Z POSITION) Y-18GA LEAD 5
BR-16GA Y-18GA LEAD 1
R-18GA Y-18GA LEAD 6
R-18GA R-18GA
V-16GA R-18GA
Y-16GA
B-16GA Y-18GA LEAD 2
MOTOR 3 (Y POSITION)
BU-16GA Y-18GA LEAD 4
Y-18GA LEAD 3
MOTOR 3 (Y POSITION) Y-18GA LEAD 5
BR-16GA Y-18GA LEAD 1
R-18GA Y-18GA LEAD 6
R-18GA R-18GA
V-16GA R-18GA
Y-16GA
MOTOR 2 (X POSITION)
B-16GA Y-18GA LEAD 2 Symbols Chart
BU-16GA Y-18GA LEAD 4
MOTOR 2 (X POSITION)
Y-18GA LEAD 3 Wire Nut
Y-18GA LEAD 5
BR-16GA Y-18GA LEAD 1 Earth Ground
R-18GA Y-18GA LEAD 6 Screw Terminal
R-18GA R-18GA
V-16GA R-18GA Earth Ground
Y-16GA
B-16GA
MAIN J-box MOTOR 1 (W POSITION)
No Connection
BU-16GA
MAIN J-box
EARTH GROUND
Connection
AC NEUTRAL
MOTOR 1 (W POSITION)
AC HOT
(3 PHASE LINES)
(3 PHASE LINES)
(3 PHASE LINES)
(3 PHASE LINES)
Crimp Connector
MOTOR 3
MOTOR 2
EARTH GROUND
MOTOR 4
AC HOT
AC NEUTRAL
MOTOR 2 - 115V
MOTOR 2 - N
MOTOR 1
MOTOR 3 - 115V
MOTOR 1 - N
MOTOR 3 - N
MOTOR 1 - 115V
MOTOR 4 - N
MOTOR 4 - 115V
GRN-18GA 3
W-18GA 2
B-18GA 1
W-18GA 2
B-18GA 1
SINGLE PHASE THREE PHASE
Y-18GA
Y-18GA
Y-18GA
Y-18GA
Y-18GA
Y-18GA
Y-18GA
Y-18GA
STP-4
STP-2
See Note 1
STP-1
STP-3
A13
A10
STP-4
STP-2
STP-1
STP-3
Orange OR
A13
A10
A2
A2
AC NEUTRAL
MOTOR 3 - LINE 1
AC HOT
MOTOR 1 - LINE 1
MOTOR 1 - LINE 2
MOTOR 4 - LINE 2
MOTOR 4 - LINE 1
MOTOR 2 - LINE 2
MOTOR 2 - LINE 1
MOTOR 3 - LINE 2
EARTH GROUND
AC NEUTRAL
(3 PHASE LINES)
(3 PHASE LINES)
(3 PHASE LINES)
Sheet 4 of 11
(3 PHASE LINES)
MOTOR 3
MOTOR 2
MOTOR 1
MOTOR 4
11/18 FE-363U
GRN OR YL/GRN-18GA 3
W-18GA 2
B-18GA 1
Y-18GA
Y-18GA
Y-18GA
Y-18GA
SINGLE PHASE
GRN-18GA 3
115 VAC FOR STP
W-18GA 2
B-18GA 1
MOTOR CONNECTION
SINGLE PHASE
Y-18GA
Y-18GA
Y-18GA
Y-18GA
Use STP motor connections 115/120VAC
115 VAC FOR STP MOTOR CONNECTION
STP-1
STP-3
STP-4
A13
A10
STP-2
A2
STP-4
STP-2
STP-1
STP-3
A13
A10
A2
GY-14GA
B-20GA GY-14GA
B-20GA B-20GA
W-14GA B-20GA
BU-14GA W-14GA
R-14GA R-14GA
BR-14GA BU-14GA
Y/GN-14GA BR-14GA
MOTOR 4 (Z POSITION) See Note 1 Y/GN-14GA
See Note 1 GY-14GA MOTOR 4 (Z POSITION)
B-20GA GY-14GA
B-20GA B-20GA
W-14GA B-20GA
BU-14GA W-14GA
R-14GA R-14GA
BR-14GA BU-14GA
Y/GN-14GA BR-14GA
MOTOR 3 (Y POSITION)
Y/GN-14GA
GY-14GA MOTOR 3 (Y POSITION)
B-20GA GY-14GA
B-20GA B-20GA
W-14GA B-20GA
BU-14GA W-14GA
R-14GA R-14GA
BR-14GA BU-14GA
Y/GN-14GA BR-14GA
MOTOR 2 (X POSITION) Y/GN-14GA
GY-14GA MOTOR 2 (X POSITION)
B-20GA GY-14GA
B-20GA B-20GA
W-14GA B-20GA
BU-14GA W-14GA
MAIN J-box R-14GA R-14GA
BR-14GA BU-14GA
Y/GN-14GA
MOTOR 1 (W POSITION) MAIN J-box BR-14GA
Y/GN-14GA
MOTOR 1 (W POSITION)
EARTH GROUND
AC HOT
AC NEUTRAL
MOTOR 2 - 115V
MOTOR 2 - N
MOTOR 3 - 115V
MOTOR 1 - N
MOTOR 3 - N
MOTOR 1 - 115V
MOTOR 4 - N
MOTOR 4 - 115V
MOTOR 3 - LINE 1
AC HOT
MOTOR 1 - LINE 1
MOTOR 1 - LINE 2
MOTOR 4 - LINE 2
MOTOR 4 - LINE 1
MOTOR 2 - LINE 2
MOTOR 2 - LINE 1
MOTOR 3 - LINE 2
EARTH GROUND
AC NEUTRAL
Notes: 1) Connections made in field.
2) Motors must rotate counterclockwise.
4
SMART Connect)
Speaker B-2 WR
Speaker B-1 WR
4
Speaker A-2 R
Speaker A-1 R
CONDUIT
CONDUIT
Call A - 1 B
6
Call A - 2 Call
(-)
B
(-)
N
L2
(+)
(+)
L1
Interface
GND
Call B - 1 WB
Call B - 2 WB Cabling
FROM CUSTOMER-PROVIDED
SMART Connect
Speaker B
Speaker A
Neutral (Valance Lights) (14 AWG)C-13 Note: For older power control
INDEPENDENT OPERATION
Earth Ground (14 AWG)C-10 module assemblies, refer
CONDUIT
SIMULTANEOUS OPERATION
CONDUIT
to MDE-3804 Encore/Eclipse
4
To Valance Lights
17
M03773A004 (700) Start-Up/Service Manual.
4
(Customer Provided)
M15290A002 (900)
J2 P2
DISPENSER M00672A004 TO M07555
BREAKERS 3
10
POWER CONTROL
HOT (CD Module) A-2 B 98-240 MODULE ASSEMBLY
VAC IN
Earth Ground A-10 GN/Y AC HOT
AC NEUTRAL DEF
STP NEUTRAL (CD Module) A-13 W GROUND HEATER
10
M03773A004
Both Master and Satellite can dispense fuel at the same time.
1 M2 GND TB2-2 thru 8 STP2/MTR2 R STP2 (DEF) 4 POWER CONTROL
Master and Satellite can dispense fuel only one at a time. Satellite
MODULE ASSEMBLY
11
ATC (-) GY ATC (-) 18 AWG GY STPs
J3105
Notes: 1) For wiring of Satellite indicator light option units, refer to pages 7 and 8.
STP ATC(+) OR ATC(+) 18 AWG OR ATC OPTION
BREAKER Gilbarco STP Isolation Box - #2 3
L1 PA0287 HTR-N W HTR-N 14 AWG W TO P3105
N HTR-H B HTR-H 14 AWG HEATER OPTION CRIND
TB1-1 B CONTROL
L2 TB2-1 NODE 3 OR
SP- 3 Y SP-3 18 AWG Y COLOR
11
unit is shown. For a one-grade
BOARD
Pump and CRIND Wiring Options
20
18
J1109
Pump Only or Generic Pump
HEATER 2
BREAKER A9 W/R Pump Two-wire Out (-) A9 W/R
Encore Ultra-Hi Electronics Cabinet
2) Depending upon the model of Ultra-Hi and Satellite, inlet and outlet conduit numbers related to Satellites may vary.
Note: Choose one of these options.
Box for
CRIND
Generic
G-SITE or
Dispensers
To D-Box for
4
To Distribution
12
To other dispensers
Spare 4 SP4 Y Spare 4 SP4 Y TO SAT RTN (when Satellite Indicator Light is present)
B-8 Y B-8 Y TO J309
B-12 R B-12 R TO P604
SATELLITE
FOR SIDE 2
SATELLITE
AND CONDUIT
CONDUIT (SIDE 2)
OR GRADE 2 OF A
TWO-GRADE UNIT
SEPARATE WIRES
This Sheet
to “B” side wiring of Satellite.
Note: Single-grade Satellite shown.
Spare 5 SP5 Y Spare 5 SP5 Y To SAT RTN (when Satellite Indicator Light is present)
A-14 BU A-14 BU TO J309
TO P604
A-8 Y A-8 Y TO J309
SATELLITE
CONDUIT (SIDE 1)
4
J-box
Optional
Optional
(Factory-installed J-box not available)
4
Speaker B-2
Make these connections to
Wire Nut
Speaker B-1 WR
Connection
Speaker A-2 R
Earth Ground
Earth Ground
Speaker A-1 R
No Connection
4
Screw Terminal
Crimp Connector
Call A - 1 B
CONDUIT
FROM
Symbols Chart
Call A - 2 B
CONDUIT
Call B - 1 WB
(NEC Class 2)
Call B - 2 WB
(must run wires in
separate conduit)
INTERCOM SYSTEM
VALANCE
10
CUSTOMER-PROVIDED
(+)
(+)
Red
Blue
Black
Violet
CONDUIT
White
(Customer
Cabling
Green
Brown
Yellow
Interface
Orange
CONDUIT 4
4
To Valance Lights
White Red
White Black
Speaker B
Speaker A
SATELLITE
10
BREAKER HOT (CD Module) A-2 B A2 HOT (CD Module) B M01591A001 Cable J401-1
8
NEUTRAL (CD Module) A-13 W A13 NEUTRAL (CD Module) W M01591A001 Cable J401-2
V
Y
B
W
BU
BR
Earth Ground A-10 GN/Y A10 Earth Ground G M01591A001 Cable J401-3
GY
GN
OR
WR
WB
STP1/MTR1 R STP1
STP2/MTR2 R STP2
ATC R ATC R
ATC R ATC R
Spare 1 SP1 Y SP1 Y
Spare 2 SP2 Y SP2 Y
2
11/18
A
combo is the same.
FS (-) W FS (-) W
FS (+) W FS (+) W
A-9 W/R PUMP TWO-WIRE W/R
electrode.
W/B
B-21 W/R CRIND TWO-WIRE W/R
Note: Encore Satellite showing only wiring
connections to Satellite. Wiring for a
B-9 Y B-9 Y
Encore Ultra-Hi Satellite Electronics Cabinet
B-19 Y B-19 Y
EMERGENCY POWER B-8 Y B-8 Y
1
CUTOFF
4
B-12 R B-12 R
120/240 VAC
Satellite.
Sheet 6 of 11
BU BU
Note: Use these wires for
B-14 B-14
a one-grade
a two-grade Satellite.
N
L1
L2
Note: Wire shown for
A
LOAD CENTER
PHASE 50/60 HZ
J-box
120/240 VAC SINGLE
Optional
Connect only when indicator light is present or if
ENCORE MASTER ELECTRONICS CABINET - MASTER
FOR SIMULTANEOUS OPERATION - ENCORE MASTER/LEGACY SATELLITE - INDEPENDENT OR SIMULTANEOUS OPERATION (TWO-STAGE VALVE)
OPTION WITH SATELLITE INDICATOR LIGHT AND VALVE LEAVE JUMPER/CONNECTOR P322 INSTALLED
CONTROL ASSEMBLY (M02652A010/M02652A011) P322
M04218A001
J322 ENCORE MASTER
INSTRUCTIONS FOR SIMULTANEOUS AND INDEPENDENT 5
OPERATION ARE SHOWN HERE FOR INDEPENDENT OPERATION - CONNECT J322 R-18GA R-18GA
LEGACY SATELLITE
SAME FOR
ON CABLE M04218A001 TO P322 ON SATELLITE
"B" SIDE
Note: Satellite Indicator PCA (M2297A001)/Assembly M02652A009 INDICATOR PCA M04570A001/ASSY M02652A011.
will not support INDEPENDENT operation. SATELLITE Y-18GA Y-18GA
J-bOX
BU-18GA BU-18GA
(700)
A8
CONDUIT
M15289A001 (900) B -18GA
J321
SATELLITE NO. 1
P321
P322
NO
M04570A001*
NC
NO
NC
(TO REMOTE SATELLITE)
R - 18GA A13
J322 SATELLITE INDICATOR PCA
(SCHEMATIC M04568) BU-18GA A12
FROM ENCORE SATELLITE OR COMBO
R
M04218A001 TRANSFORMER
A Y CONTROL
SUB - ASSEMBLY R - 18GA A15 VALVE
M02370A001 B
"A"
BU-18GA A14
(700) ‘A’ SIDE DOOR
M02338A003 (900)
A Connect only when indicator light is present or if Satellite dispenses in independent flow.
NEUTRAL FEED B12
FOR SATELLITE B
TO J604
TO B SIDE VALVE MAIN DISTRIBUTION CABLE SIMULTANEOUS OPERATION
Both Master and Satellite can dispense fuel at the same time.
INDEPENDENT OPERATION
ENCORE MASTER ELECTRONICS CABINET - SATELLITE PORTION OF MASTER/COMBO OPTION Master and Satellite can dispense fuel only one at a time. Satellite
pump handle determines which unit can dispense fuel.
A8
(TO A8 MASTER) (Yellow)
(Black) PUMP HANDLE INTERFACE PCA
(Red)
SP3 5
P102 P101
(B
3 WIRES
la
ck
M06156A001
(R
See Note 1
Wire Color Chart
ed
(White)
Black B
A14 M04687A002
Wire Nut Brown BR
See Note 2
TO J2125 Red R
USE SP 3 - CONNECT (Blue) Earth Ground
ONLY WHEN INDICATOR LIGHT Screw Terminal Orange OR
IS PRESENT OR IF SATELLITE DISPENSES See Note 1 ‘B’ SIDE DOOR Field Wiring Diagram Encore® 500/700/900 Ultra-Hi™
Yellow Y
IN INDEPENDENT FLOW.
Earth Ground
Green GN
Dispensers Master and Satellite
This Sheet No Connection Blue BU (M07555 Power Supply Only)
Notes: 1) The black and blue wires will only be present if the Pump Handle Interface 120/240 VAC
Satellite signal wiring details for Connection Violet V
Board PCA (M05650A001) is present. If Pump Handle Interface Boards M02325A003 or
M04528A002 are used, only the red and white wires will be available. Encore Master with Encore Satellite Crimp Connector
Gray GY Sheet 7 of 11
White W
2) The wiring for the Satellite is the same except that the Satellite will use M02802A001 Cable. and Encore Master with
Legacy Satellite.
White Black WB 11/18 FE-363U
White Red WR
ENCORE MASTER TO LEGACY SATELLITES WITH TWO SINGLE-STAGE VALVES - INDEPENDENT ENCORE MASTER/LEGACY SATELLITE WITH J-BOX - SIMULTANEOUS OPERATION (TWO-STAGE VALVE) WITHOUT
OR SIMULTANEOUS OPERATION ENCORE MASTER SATELLITE INDICATOR LIGHT ON MASTER
4
A12 R-18GA B12 R-18GA ENCORE MASTER
4 A12 R-18GA
LEGACY SATELLITE
"B" SIDE
SAME FOR
A8 Y-18GA B8 Y-18GA LEGACY SATELLITE
SAME FOR
"B" SIDE
A14 BU-18GA B14 BU-18GA A8 Y-18GA
B -18GA A8 SATELLITE
J-BOX A14 BU-18GA
CONDUIT
See Note 1
CONDUIT
B -18GA A8
SLOW FLOW
VALVE
NC
NO
R - 18GA A13
NC
NO
SATELLITE NO. 1
SATELLITE NO. 1
NO
NC
NO
NC
R - 18GA A13 AC Neutral
BU-18GA A12
BU-18GA A12
R
R - 18GA A15 Y CONTROL
R - 18GA A15 FAST FLOW
B VALVE
VALVE "A"
BU-18GA A14
TO SAT RTN OF M04218 CABLE BU-18GA A14
See Note 1
A
Notes: 1) For this option you will be modifying wiring at the handle switch of the Legacy satellite.
Notes: 1) M04570A001 Satellite indicator must be used in Encore units
Connect only when indicator light is present or if You will be removing the A8 wire to the switch and connecting wires from the Encore
in order to function in independent flow. A
Satellite dispenses in independent flow. Master valve to the inlets of the switch.
2) In single-stage valve, only the fast flow valve is present.
2) Alternative wiring method: This method of wiring is often required to allow Encore Master to
This unit is not preset-capable.
hit presets. This method will not support independent operation or Satellite indicator light.
4
Speaker B-2 WR
Speaker B-1 WR
4
Speaker A-2 R
Speaker A-1 R
CONDUIT
CONDUIT
Call A - 1 B
Call A - 2 Call
(-)
B
(-)
(+)
(+)
N
Interface
L2
L1
Call B - 1
15
WB
6
GND
Call B - 2 WB Cabling
FROM CUSTOMER-PROVIDED
120 VAC HOT (Valance Lights) (14 AWG) C-2
Speaker B
Speaker A
CONDUIT
CONDUIT
4
To Valance Lights
15
4
(Customer Provided)
DISPENSER
10
BREAKERS M03773A008 (E700)
HOT (CD Module) A-2 B M15290A002 (E900)
J2 P2
Earth Ground A-10 GN/Y M00672A004 TO M07555A001
3 POWER CONTROL
NEUTRAL (CD Module)A-13 W MODULE ASSEMBLY
M03773A004 98-240
NEUTRAL (LAMP) A-11 W LMP-N A-11 W VAC IN
HOT (LAMP) A-1 B LMP-H A-1 B
J1302 P1302
STP1/MTR1 R STP1 TO M07555A001
of Skid Tank
4 POWER CONTROL
To STP Control
STP2/MTR2 R STP2
MODULE ASSEMBLY
ATC (-)
16
GY ATC (-) 18 AWG GY STPs
J3105
ATC(+) OR ATC(+) 18 AWG OR ATC OPTION
3
HTR-N W HTR-N 14 AWG W TO P3105
HTR-H B HTR-H 14 AWG HEATER OPTION CRIND
B
Not Used
CONTROL
NODE 3 OR
SP- 3 Y SP-3 18 AWG Y COLOR
SP- 2 Y SP-2 18 AWG Y SCREEN
SPARE WIRES CRIND
SP- 1 Y SP-1 18 AWG Y
INTERFACE
BOARD
Pump and CRIND Wiring Options
MAIN FIELD CONDUIT
J1109
Pump Only or Generic Pump
2
A9 W/R Pump Two-wire Out (-) A9 W/R
A19 W/B Pump Two-wire In (+) A19 W/B TO P1109
P100 J100 PUMP
CONTROL
Pump & CRIND for MOC or Generic CRIND NODE 2
B20 W/B CRIND Two-wire Out B20 W/B 4 4
M03773A004 M03773A004
for Generic
This Sheet
Note: Choose one of these options.
Dispensers
To D-Box for
To D-Box for
M03773A008 (E700) & M15290A002 (E900)
Spare 4 SP4 Y Spare 4 SP4 Y TO SAT RTN (when Satellite Indicator Light is present)
B-8 Y B-8 Y TO J309
B-12 R B-12 R TO P604
B-14 BU B-14 BU TO J309
ENCORE ULTRA-HI MAIN CONDUIT AND CABLE ASSEMBLY
Not Used
Spare 5 SP5 Y Spare 5 SP5 Y To SAT RTN (when Satellite Indicator Light is present)
A-14 BU A-14 BU TO J309
A-12 R A-12 R
TO P604
A-8 Y A-8 Y TO J309
4
J-BOX
Optional
Wire Nut
Connection
Earth Ground
Earth Ground
No Connection
Screw Terminal
Symbols Chart
Crimp Connector
Red
Blue
Gray
Black
Violet
White
Green
Brown
Yellow
Orange
White Red
White Black
Wire Color Chart
V
Y
B
W
BU
BR
GY
GN
OR
WR
WB
11/18
Note: For DEF+1 Units, refer to Field Wiring Diagram Encore 500 Ultra-Hi/700 Ultra-Hi
Sheet 9 of 11
(Single-grade DEF only)
Dispensers, DEF+1, and Satellites (M07555 Power Supply Only) 120/240 VAC on Sheets 6 and 10.
FE-363U
Field Wiring Diagram Encore® DEF Dispensers
(Factory-installed J-box not available) J-box
supplied by installing contractor (may be required for retrofit
installations) SMART Connect Wiring Communication
-Twisted Pair (Factory installed. Does not support
4
SMART Connect)
Speaker B-2 WR
Speaker B-1 WR
4
Speaker A-2 R
Speaker A-1 R
CONDUIT
CONDUIT
Call A - 1 B
6
Call A - 2 Call
(-)
B
(-)
N
L2
(+)
(+)
L1
Interface
GND
Call B - 1 WB
Call B - 2 WB Cabling
FROM CUSTOMER-PROVIDED
SMART Connect
Speaker B
Speaker A
Neutral (Valance Lights) (14 AWG)C-13 Note: For older power control
INDEPENDENT OPERATION
Earth Ground (14 AWG)C-10 module assemblies, refer
CONDUIT
SIMULTANEOUS OPERATION
CONDUIT
to MDE-3804 Encore/Eclipse
4
To Valance Lights
M03773A008 (E700)
17
Start-Up/Service Manual.
4
(Customer Provided)
M15290A002 (E900)
J2 P2
DISPENSER M00672A004 3 TO M07121A004
BREAKERS 3
10
POWER SUPPLY
HOT (CD Module) A-2 B 98-240
VAC IN
Earth Ground A-10 GN/Y AC HOT
AC NEUTRAL DEF
STP NEUTRAL (CD Module) A-13 W GROUND HEATER
10
M03773A004
Both Master and Satellite can dispense fuel at the same time.
1 M2 GND TB2-2 thru 8 STP2/MTR2 R STP2 (DEF) 4
Master and Satellite can dispense fuel only one at a time. Satellite
11
ATC (-) GY ATC (-) 18 AWG GY STPs
J300
Notes: 1) For wiring of Satellite indicator light option units, refer to pages 6 and 7.
STP ATC(+) OR ATC(+) 18 AWG OR ATC OPTION
BREAKER Gilbarco STP Isolation Box - #2 4
L1 PA0287 HTR-N W HTR-N 14 AWG W TO P300
N HTR-H B HTR-H 14 AWG DEF HEATER* OF
TB1-1 B M13124A001
L2 TB2-1 OR
SP- 3 Y SP-3 18 AWG Y M15351A001
11
unit is shown. For a one-grade
Pump and CRIND Wiring Options
20
18
Pump Only or Generic Pump
HEATER
BREAKER A9 W/R Pump Two-wire Out (-) A9 W/R
Encore Ultra-Hi Electronics Cabinet
2) Depending upon the model of Ultra-Hi and Satellite, inlet and outlet conduit numbers related to Satellites may vary.
Note: Choose one of these options.
To Distribution
on wire A-10.
M03773A008 (E700) & M15290A002 (E900)
12
To other dispensers
Spare 4 SP4 Y Spare 4 SP4 Y TO SAT RTN (when Satellite Indicator Light is present)
B-8 Y B-8 Y TO J309
B-12 R B-12 R TO P604
SATELLITE
FOR SIDE 2
SATELLITE
AND CONDUIT
CONDUIT (SIDE 2)
OR GRADE 2 OF A
TWO-GRADE UNIT
SEPARATE WIRES
This Sheet
to “B” side wiring of Satellite.
Note: Single-grade Satellite shown.
Spare 5 SP5 Y Spare 5 SP5 Y To SAT RTN (when Satellite Indicator Light is present)
A-14 BU A-14 BU TO J309
J-box
Optional
Optional
(Factory-installed J-box not available)
4
Speaker B-2
Make these connections to
Wire Nut
Speaker B-1 WR
Connection
Speaker A-2 R
Earth Ground
Earth Ground
Speaker A-1 R
No Connection
4
Screw Terminal
Crimp Connector
Call A - 1 B
CONDUIT
FROM
Symbols Chart
Call A - 2 B
CONDUIT
Call B - 1 WB
(NEC Class 2)
Call B - 2 WB
(must run wires in
separate conduit)
INTERCOM SYSTEM
VALANCE
10
CUSTOMER-PROVIDED
(+)
(+)
Red
Blue
Black
Violet
CONDUIT
White
(Customer
Cabling
Green
Brown
Yellow
Interface
Orange
CONDUIT 4
4
To Valance Lights
White Red
White Black
Speaker B
Speaker A
SATELLITE
10
BREAKER HOT (CD Module) A-2 B A2 HOT (CD Module) B M01591A001 Cable J401-1
8
NEUTRAL (CD Module) A-13 W A13 NEUTRAL (CD Module) W M01591A001 Cable J401-2
V
Y
B
W
BU
BR
Earth Ground A-10 GN/Y A10 Earth Ground G M01591A001 Cable J401-3
GY
GN
OR
WR
WB
STP1/MTR1 R STP1
STP2/MTR2 R STP2
ATC R ATC R
ATC R ATC R
Spare 1 SP1 Y SP1 Y
Spare 2 SP2 Y SP2 Y
2
11/18
A
combo is the same.
FS (-) W FS (-) W
FS (+) W FS (+) W
A-9 W/R PUMP TWO-WIRE W/R
electrode.
W/B
B-21 W/R CRIND TWO-WIRE W/R
Note: Encore Satellite showing only wiring
connections to Satellite. Wiring for a
B-9 Y B-9 Y
Encore Ultra-Hi Satellite Electronics Cabinet
B-19 Y B-19 Y
EMERGENCY POWER B-8 Y B-8 Y
1
CUTOFF
4
B-12 R B-12 R
120/240 VAC
Satellite.
Sheet 10 of 11
BU BU
Note: Use these wires for
B-14 B-14
a one-grade
a two-grade Satellite.
N
L1
L2
Note: Wire shown for
A
A-8 Y A-8 Y
TO SHUTOFF VALVE
ENCORE ULTRA-HI MAIN CONDUIT AND CABLE ASSEMBLY M03266A002
LOAD CENTER
PHASE 50/60 HZ
J-box
120/240 VAC SINGLE
Optional
Connect only when indicator light is present or if
(Factory-installed J-box not available)
J-box supplied by installing contractor
(may be required for retrofit installations)
SMART Connect Wiring Communication
-Twisted Pair (Factory installed. Does not
support SMART Connect)
4
Speaker B-2 WR
Speaker B-1 WR
4
Speaker A-2 R
Speaker A-1 R
CONDUIT
CONDUIT
Call A - 1 B
Call A - 2 Call
(-)
B
(-)
(+)
(+)
N
Interface
L2
L1
Call B - 1
15
WB
6
GND
Call B - 2 WB Cabling
FROM CUSTOMER-PROVIDED
120 VAC HOT (Valance Lights) (14 AWG) C-2
Speaker B
Speaker A
CONDUIT
CONDUIT
4
To Valance Lights
15
4
(Customer Provided)
DISPENSER
10
BREAKERS M03773A008 (E700)
HOT (CD Module) A-2 B M15290A002 (E900)
J2 P2
of Skid Tank
4
To STP Control
STP2/MTR2 R STP2
ATC (-)
16
GY ATC (-) 18 AWG GY STPs
J300
ATC(+) OR ATC(+) 18 AWG OR ATC OPTION
4
HTR-N W HTR-N 14 AWG W TO P300
HTR-H B HTR-H 14 AWG B HEATER OPTION OF
Not Used
M13124A001
SP- 3 Y SP-3 18 AWG Y OR
M15351A001
SP- 2 Y SP-2 18 AWG Y SPARE WIRES
SP- 1 Y SP-1 18 AWG Y
Pump and CRIND Wiring Options
MAIN FIELD CONDUIT
This Sheet
Note: Choose one of these options.
Dispensers
To D-Box for
To D-Box for
Spare 4 SP4 Y
M03773A008 (E700) & M15290A002 (E900)
Not Used
Spare 5 SP5 Y Spare 5 SP5 Y To SAT RTN (when Satellite Indicator Light is present)
A-14 BU A-14 BU TO J309
A-12 R A-12 R
TO P604
A-8 Y A-8 Y TO J309
4
J-BOX
Optional
Wire Nut
+1,
Connection
Earth Ground
Earth Ground
No Connection
Screw Terminal
Symbols Chart
Crimp Connector
Red
Blue
Gray
Black
Violet
White
Green
Brown
Yellow
Orange
White Red
White Black
Wire Color Chart
V
Y
B
W
BU
BR
GY
GN
OR
WR
WB
11/18
Note: For DEF+1 Units, refer to Field Wiring Diagram Encore Ultra-Hi Dispensers, DEF
and Satellites (M07555 Power Supply Only) 120/240 VAC on Sheets 6 and 10.
Sheet 11 of 11
(Single-grade DEF only)
FE-363U