240 KNM and M 150 Knm. Check The Adequacy of The Reinforcement. 50 MM, All Bars Are N32, F
This document contains 3 questions related to the design of reinforced and pre-cast concrete structures:
1) A column undergoing biaxial bending and axial load is checked for adequacy of reinforcement.
2) A slender column symmetrically reinforced with steel bars is designed to resist an axial load, and its maximum moment carrying capacity is calculated.
3) Losses in prestress are estimated for a post-tensioned beam, including elastic deformation, friction, anchorage slip, shrinkage, creep, and tendon relaxation losses.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
25 views1 page
240 KNM and M 150 Knm. Check The Adequacy of The Reinforcement. 50 MM, All Bars Are N32, F
This document contains 3 questions related to the design of reinforced and pre-cast concrete structures:
1) A column undergoing biaxial bending and axial load is checked for adequacy of reinforcement.
2) A slender column symmetrically reinforced with steel bars is designed to resist an axial load, and its maximum moment carrying capacity is calculated.
3) Losses in prestress are estimated for a post-tensioned beam, including elastic deformation, friction, anchorage slip, shrinkage, creep, and tendon relaxation losses.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
Tutorial 10 Week 12
Course: CEB706 – Designed of Reinforced & Pre-Cast Concrete Structures
Tutorial: 10 - General
Q1: Biaxial Bending and axial force in Column
A rectangular column shown below is to be designed for N* = 2400 kN and bending moments Mx* = 240 kNm and M y* = 150 kNm. Check the adequacy of the reinforcement. (dsc = 50 mm, all bars are N32, fc’ = 40 MPa) y 600 mm
400 mm
Q2: Slender Column
A 400 mm square column is symmetrically reinforced with 6N32 bars. The beam need to be designed for N* = 3750 kN. If the effective length of the beam is 4000 mm, what is the maximum moment it can carry? (dsc = 40 mm, fc’ = 40 MPa)
Q3: Losses in Prestress
Estimate the losses for a simply supported post-tensioned beam which spans 20 m and has the 400 x 900 mm rectangular cross section. The prestressing steel is contained in two cables, each consisting of 6 super grade 7-wire strand of 12.7 mm diameter. For each cable, the area is 600 mm2. The cables have parabolic profile with zero eccentricities at each ends and 350 mm at mid span. The concrete strength is 45 MPa and fcp can be taken as 35 MPa. Initial prestress is 1500 kN. You need to estimate the i. Loss due to Elastic Deformation ii. Loss due to friction along the tendon iii. Anchorage Slip iv. Shrinkage loss v. Creep loss vi. Loss due to relaxation of tendon You may need to refer the sections 6.3 and 6.4 in AS3600.