XCSF Remote Console Guide
XCSF Remote Console Guide
User's Guide
- System Monitor and Control Facility (eXtended System Control Facility: XSCF) User's Guide -
C120-E184-02EN
i
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter6 How to Use the XSCF Command Shell 6-1
Overview of XSCF Command Shell 6-2
Login to XSCF User Account 6-4
Server Status and Control Commands 6-6
XSCF Log View Command 6-13
XSCF Server Configuration Information Command 6-21
Other XSCF Commands 6-25
XSCF Shell Error Messages 6-28
ii
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Glossary W-1
iii
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Preface
About This Manual
[Purpose]
This manual describes the system monitor and control facility (eXtended System Control Facility,
or XSCF, hereafter) used to control, monitor, operate, and service PRIMEPOWER series servers
and their systems. XSCF may also be referred to as the System Control Facility (SCF).
[Audience]
This manual is intended for users, specifically system management/maintenance administrators.
[Organization]
This manual consists of the following chapters:
● Overview
● Setting up XSCF
● Connecting XSCF or Server
● How to use the remote panels
● How to use the XSCF Web function
● How to use the XSCF command shell
● XSCF SNMP agent function
● XSCF mail function
● XSCF firmware and dump
● Warning Messages
● XSCF Log Information
● XSCF MIB
● Troubleshooting
● Glossary
[Related Manuals]
Refer to the following manuals as necessary:
Microsoft is a registered trademark of Microsoft Corporation in the United States and/or other
countries.
Netscape and Netscape Navigator are trademarks or registered trademarks of Netscape
Communications Corporation in the United States and/or other countries.
Other company and product names are trademarks or registered trademarks of their respective
owners.
iv
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
[Acknowledgement]
The TCP/IP-based communication functions of the LAN-communication administration functions
described in this manual were developed by Fujitsu Ltd. according to BSD NETWORKING
SOFTWARE RELEASE 1, 4.4 BSD Lite 2, and their documentation under license from the
University of California at Los Angels (UCLA). We express our gratitude to the Computer
Systems Research Group and Electrical Engineering and Computer Science Department at UCLA,
Berkeley.
Note that Fujitsu Ltd. holds the copyright on the TCP/IP-based communication functions for
XSCF and any secondary documentation related to them.
Copyright (c) 1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994
The Regents of the University of California. All rights reserved
XSCF Web Access was developed with the use of Apache and OpenSSL and mod_ssl. We
would like to express our gratitude to the Apache Group, OpenSSL Project, Mr. Eric Young and
mod_ssl project.
This product includes software developed by the Apache Group for use in the Apache HTTP
server project (http://www.apache.org/).
This product includes software developed by the OpenSSL Project for use in the OpenSSL
Toolkit. (http://www.openssl.org/)
This product includes software developed by Ralf S. Engelschall <[email protected]> for use
in the mod_ssl project (http://www.modssl.org/).
April 2003
[Important]
Do not copy the whole or any part of this manual without permission.
This manual is subject to change without prior notice.
Electrical form of this manual is installed under following path:
The revised edition for this manual can be referred to from the following path on the server (or
HCP-CD*):
/opt/FJSVhcp/manual
*HCP (: An abbreviation of Hardware Control Program. HCP is a control program of
hardware that configures a computing system.)
When you face different description written on the online manual from what written on paper
manual, please follow the online manual. Path: /PWPL0/MANUAL
The MIB new file can be refferred to from the following path in the HCP-CD.
/PWPL0/MIB
v
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Summary of Changes in Second Edition
The current, second edition of this manual differs from previous edition with Revision1
principally by containing the menus of Machine Administration function. The second edition
contains minor clarifications and corrections and also the following significant changes relative to
the previous edition with Revision1.
l Preface:
― In "Caution", a description is changed that we do not support "The DNS function in
case of using XSCF Mail function".
― In "Caution", a description of "XSCF SNMP Agent function" is deleted.
l Chapter 2, "Setting Up XSCF":
― The menu name of "Basic configuration" and the described section is changed to
two new menus, "Network Configuration" and "Console Administration". The
contents are as follows.
‐ In the menu of "Basic configuration", each options, "Basic network
configuration" and "Host name configuration" are moved to "Network
Configuration" menu. The section of "Network Configuration" is added.
‐ In the menu of "Basic configuration", each options, "Select Standard
console", "Access control of console port", and "Auto-disconnect
administration" are moved to "Console Administration" menu. The section
of "Console Administration" is added.
‐ The section of "Basic configuration" is deleted.
― Option and description of "Name server configuration" in all menu is deleted.
(In Chapter8 and AppendixD, descriptions of "DNS function" or "Name server
configuration" are deleted at the same time.)
― In "Console Administration", a description of "Caution" is added in "Access Control
of Read-only Console"'s Remarks of Table 2-3.
l Chapter 3, "Connecting XSCF or Server":
― In "Connecting Terrminals to XSCF", descriptions are added as follows:
‐ A description of "Read-only console" is added in Table3-1.
‐ A description of "break" is added.
― In "How to Configure RCI", the definition of "Automatic power-on prohibition mode
after the forced power off " in the mode "mode of power supply for remote control "
is added.
― "How to change the input-output destination of OS console to tty-a" is added.
l Chapter 4, "How to Use the Remote Panel": In "Before using the remote Panel", a
description of "Basic settings" is changed to "Network settings" and "Console settings".
l Chapter 5, "How to Use the XSCF Web Function ":
― In "Table 5-1 XSCF Web function pages", a description of "Authentication" page is
added.
― In "Function to be enabled on the browser", Items are corrected as follows:
‐ A description of option setting on Microsoft(R) Internet Eplorer is added.
‐ In "Cookies", a description of "(in cache only; it don't have to be stored)"
is deleted.
― In "Logging In to or Out from XSCF", a description of "Condition" of "Logging out
from XSCF"is corrected.
l Chapter 6, "How to Use the XSCF Command Shell":
― The commands of "net-status", "show-shell-command" are added.
― A note in the "set-console-device" command is added.
l Chapter 7, "XSCF SNMP Agent function": In "Installation case to SystemWalker",
Descriptions of "a setup which calls "XSCF WEB function from SystemWalker" is added.
vi
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
l Chapter 8, "XSCF Mail Function ":
― In "Features of the XSCF mail function", Description of "Sending e-mail directly" by
setting name server is deleted.
― In "Setting up the XSCF Mail Function", description of name server setting at Step 1
and Note are deleted. At Step1, the "Mail administration" menu of the Machine
Administration menu is described.
l Appendix B, "XSCF Log Information":
― "XSCF Error Log List" are corrected.
‐ In the hardware which detects an error , "Machine Administration" is added.
Therefore, some tables at each error level are added.
‐ The following error code numbers are corrected.
4E20F500 -> 4E20F50n, 82130400 -> C2130400, C21110FF -> C2111000,
C21111FF -> C2111100, C21112FF -> C2111200
‐ Descriptions of error codes 408055FF, 430103FF, 431501FF, 4E20F00n,
4E20F600, 501012FF, 830B130n, 830E000n, 8E07200n, 8E20F40n,
C202020n, C202050n, C2111000, C2111100, C2111200, C2130400,
C30B140n, C30E010n(Alarm), C30E010n(Warning), C30E020n, C30E030n,
C30E040n, C30E050n, CE20020n and CE20040n are corrected.
‐ Error codes 41110000, 430E060n, 46110000, 60000100, 81110000,
86110000, 8E208500, 8E208600, 8E20F700, A0000100, C1110000,
C20107FF, C6110000, CE209400, CE209500, CE209600 and E0000100 are
added.
‐ Error codes 431608FF, 501030FF and 501031FF are deleted.
‐ In Table parts number, U2P, Error log for test, IO-BP, POWER-BD and PSU-
CAGE are added.
‐ Components, U2P and U2P(Timer) numbers are corrected as below:
#0-#3 -> #0,#2,#3
― "XSCF Event Log List" are corrected.
‐ Power: The definition of Byte1 and Byte2 are corrected. In the "VV"
definition, "x05, A power supply error occurred" , the definition of Byte1 and
Byte2 are added.
‐ Nodeself: In the "The sensor failed" definition, the detail definitions are
added.
‐ Config: The bits definition of "ss, the old unit status" is added.
‐ The term of factor "SparcReq" is corrected to "CPUReq".
‐ SparcReq: In the "VV" definition, "Request to SPARC for event " is added.
In the "Request to SPARC for shutdown" definition, descriptions of "event
code" and "Detailed code" are added.
‐ Panel: In the "Operation panel events" definition, "x82, The RESET switch
button pressed for a long time" is deleted.
‐ Console:
‐ RCI: The definitions are added. These are:
"x10, The RCI sending event ", "x20, The RCI receiving event "
"x30, The RCI initial operation", "x31, The RCI initial configuration"
"x32, The RCI initial reconfiguration ", "x3F, The RCI configuration result "
l Appendix C, "XSCF MIB ": Object ID and Table of "scfMonitor group" is added.
l Appendix D, "Troubleshooting":
― In "A console the XSCF shell or a standard console was suddenly disconnected", a
description of "Name server configuration" is deleted.
― In "Could not log in to XSCF Web function", the description is all corrected.
― In "Do not know the IP address of XSCF", a description of "Show current
configuration" of "Basic configration" is changed to "Network Configuration".
vii
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
l Glossary :
― The term "SCF-IMAGE" is changed to "WEBDATA".
― The term "Shadow console" is changed to "Read-only console". And the port
number "8101" is corrected to "8011".
― The terms of "IO-BP", "POWER-BD" and "PSU-CAGE" are added.
Shell Prompts
Table P-2 Shell prompts
Shell Prompt
viii
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
eXtended system Control Facility SCF>
machine_name%
machine_name#
Other shell
$
#
OpenBoot PROM ok
Caution
The following function will be supported at HCP version 0201 or later. Please ask Sales
Department the obtaining method.
● In Chapter2 and Chapter8 on first edition of this manual, the menu of "name server
configuration" is not exist now.
About "The DNS function in case of using XSCF Mail function", we have said
that it will be to support at HCP version 0201 or later in first edition Revision1 of this
manual. However, we do not support because of the following reasons:
1)You can use the Mail Sending function via a SMTP server.
2)Development convenience.
ix
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
x
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter1 Overview of XSCF
This chapter provides an overview of the system monitor and control facility (eXtended System
Control Facility, or XSCF).
Contents:
1.1 XSCF Features 1-2
1.2 Types of Connection to XSCF 1-5
1.3 XSCF User Interfaces 1-7
1.4 XSCF Monitoring and Linkage to Other Functions 1-9
1.5 Time synchronization 1-12
1-1
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter1 Overview of XSCF
XSCF is single centralized point for control of cooling system (fan units), power supply units,
system status monitor, power-on and power-off of peripheral devices, and error monitor. XSCF
offers several features to achieve greater reliability and availability. For instance, with
using XSCF, 1) you can monitor a server over a serial port or Ethernet so that the user
can control the server from a remote location, you can even use console from the remote
location, 2) errors or failures will be reported to the system administrator, automatically.
1. Power control
XSCF can be used to turn on or off server power as indicated below in addition to the
power button on the operating panel.
For information about the settings for a power failure, see the Machine Administration
Guide for the Enhanced Support Facility (ESF).
For more information about the remote panel, see "Chapter4 How to Use the Remote
Panel".
1-2
All Rights Reserved, Copyright(C) FUJITSU LIMITED 2003
1.1 XSCF Features
4. Networking features
To provide system-independent access to the server, XSCF provides networking functions
that do the following:
- Monitor the server even when the OS is inactive.
- Enable remote operation of the server.
- Report error messages by e-mail to specified addresses.
● Monitoring of the power supply, fans, DC voltage, system board, memory, CPU, and other
components
XSCF monitors the status of each component. In an error is detected in a component, an
error message is generated and displayed. Based on the error message, the system
administrator can easily identify a component that needs to be replaced.
● Temperature monitor
XSCF monitors the temperatures of the cabinet and CPU. If an abnormal temperature is
detected, an error message is generated and displayed. The error messages make it
possible to prevent the server from rising to a higher temperature and to prevent server
instability.
6. Security
XSCF logs incorrect accesses and unauthorized access to the system. The log can be used to
1-3
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter1 Overview of XSCF
Note:
Status of components informed by SCF could be different from one, which is informed by
machine administration menu of ESF.
While Solaris is running, some of hardware components, such as CPU, is managed by Solaris.
And, change of some status, such as degradation of CPU by Solaris, may be informed to SCF
only during shutting down or rebooting.
Therefore, different information could be displayed between XSCF and machine
administration menu.
To check the current system status during Solaris is running, using machine administration
menu is recommended.
1-4
All Rights Reserved, Copyright(C) FUJITSU LIMITED 2003
1.2 Types of Connection to XSCF
Note:
We strongly recommend that you should set the input-output destination of the OS console to the
tty-a (Especially, when you use the PGX). For more detail about changing the console to "tty-a",
see "Chapter3 Connecting XSCF or Server".
The serial port enables UNIX workstations, Windows PCs, and ASCII terminals to connect to
XSCF through the serial (RS-232C) port. The XSCF shell can be used with the serial port.
SCF-LAN Ethernet
SCF-LAN Ethernet enables UNIX workstations, Windows PCs, and ASCII terminals to connect to
XSCF through the SCF-LAN port. The following can be used with SCF-LAN Ethernet:
1-5
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter1 Overview of XSCF
For more information about the above items, see the following chapters:
1-6
All Rights Reserved, Copyright(C) FUJITSU LIMITED 2003
1.3 XSCF User Interfaces
To use the function to explain as follows, the account registration to XSCF is needed.
Please do the account registration before you start using the XSCF functionality. (No pre-
defined account is registered for the security reason.) In addition, we strongly recommend you to
register an account for our field engineer (hereafter, FE) during initial set up in consideration of
possible future maintenance work by FE.
XSCF allows up to two XSCF shell terminals at the same time when both SCF-LAN and serial
port are in use. In addition, XSCF enables multiple XSCF Web sessions. The "Standard console"
(OS console) can be used on either type of connection.
For information about connection to XSCF consoles, see "Chapter 3 Connecting XSCF or
Server".
To use these XSCF interfaces, users need to log in to XSCF with an XSCF account, then enter a
password. If a user failed to log in to XSCF five consecutive times within 3 minutes due to
invalid acount or password, a login failure is e-mailed to the system administrator. When a user
successfully logs in to XSCF but the user leaves the session without any activities for a specified
1-7
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter1 Overview of XSCF
The table below shows which XSCF functions can be used on either type of connection.
Table 1-1 XSCF functions usable on the serial port and SCF-LAN Ethernet
SCF-LAN
Function Description Serial port
Ethernet
XSCF shell ● Monitors the server. S S
The status of the server can be checked.
● Server power can be controlled from a remote
location.
Server power can be turned on and off and the
system can be rebooted from a remote location.
● Displays the server configuration.
The internal configuration of the server can be
checked.
XSCF Web Provides the same functions as the functions of the - S
function XSCF shells, but provides graphical displays for
easier operation.
Mail report Reports errors and failures by e-mail so that - S
immediate measures can be taken.
SNMP trap report Enables consolidated control for server - S
administration in conjunction with SNMP manager.
Standard console You can access to the OS console and/or OBP S S
prompt.
S: Supported. -: Not supported.
1-8
All Rights Reserved, Copyright(C) FUJITSU LIMITED 2003
1.4 XSCF Monitoring and Linkage to Other Functions
XSCF monitors the system, and log errors in case it happens. This section describes the error
log and how it is handled by the XSCF functions.
XSCF logs detected hardware related errors, and, in parallel, informs warning messages. This log
called as "Hardware error log".
Figure 1-2 shows how an error logged by XSCF is simultaneously reported to users by each of
the XSCF functions.
How XSCF logs hardware errors and how the XSCF functions report errors are described below.
1-9
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter1 Overview of XSCF
Other XSCF logs and their linkage with the XSCF functions
In addition to "Hardware error log", XSCF also stores the following types of logs:
Table 1-3 below shows reaction of XSCF against some typical events. This table shows you
the types of logs XSCF will take, way to display the taken log and method to report it to
administrators.
Table 1-3 Types of logs and related functions for some typical events
XSCF functions associated with the log
Event Log XSCF XSCF SNMP Mail
type shell Web agent function
function function
XSCF logins a, ev S N N N
1-10
All Rights Reserved, Copyright(C) FUJITSU LIMITED 2003
1.4 XSCF Monitoring and Linkage to Other Functions
For information about how and when to log events, see the following chapters:
● Referencing logs with XSCF shells: "Chapter 3 Connecting XSCF or Server", "Chapter6
How to Use the XSCF Command Shell", and "Appendix B XSCF Log Information"
● XSCF Web function: "Chapter4 How to Use the Remote Panels" and "Chapter5 How to
Use the XSCF Web Function"
● MIB list: "Appendix C XSCF MIB "
Each XSCF function needs set up in prior to its start of using. See "Chapter2 Setting Up
XSCF".
1-11
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter1 Overview of XSCF
However, when you rewind the clock of OS, this will interfere the logging mechanism of
following logs. The order of logged events might be different from original order, or a part of
events could even be disappear when you look the following logs on Machine Administration
function.
● error logs
● power logs
● event logs
● access logs
1-12
All Rights Reserved, Copyright(C) FUJITSU LIMITED 2003
Chapter 2 Setting Up XSCF
Contents:
2.1 XSCF Setup Flow 2-2
2.2 Specifying the XSCF Settings 2-4
2.2.1 Network Configuration 2-4
2.2.2 User Account Administration 2-7
2.2.3 Console Administration 2-11
2.2.4 XSCF Web Administration 2-14
2.2.5 SNMP Administration 2-18
2.2.6 Mail Administration 2-22
2-1
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 2 Setting Up XSCF
To make the settings, use the Machine Administration Menu, which runs on Solaris OE.
The setup flow is outlined below. For details of how to specify the settings, see the sections
following this section.
5. Configure the XSCF Web. (Optional, but recommended, because you can more easily
manage the system from the remote Web browser.)
- Enable/Disable XSCF Web
- Select locale
- Appearance of Web page
- Access control
2-2
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
2.1 XSCF Setup Flow
6. Set up the SNMP configuration. (Optional, but recommended if you have SNMP manager.
You can achieve consolidated management of system with using SNMP manager.)
- Port Setting
- Management Information
- sysContac
- sysName
- sysLocation
- Register community
- Delete community
7. Set up the Mail reporting function. (Optional, but recommended because you can receive
a mail from system in case of error.)
- Mailer Setting
- Server Setting
- Mail Destination Address Setting
- From: Header Setting
Information
Those window images are samples. It differs from an actual screen.
2-3
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 2 Setting Up XSCF
XSCF Host Name Specify the host name of XSCF. The host name Note:
can be specified up to 63 characters. Please The character which can
set it in the FQDN(Fully Qualified Domain be specified is
Name) format. Alphanumeric character
(a-z,A-Z,0-9),hyphen (-)
and period (.).
1. Network Configuration
2. User Account Administration
3. Console Administration
4. XSCF Web Administration
5. SNMP Administration
6. Mail Administration
IP Address
Choose "IP Address" in "Network Configuration" menu by number.
Examples:
2-4
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
2.2 Specifying the XSCF Settings
Network Configuration
1. IP Address:0.0.0.0
2. Subnet Mask:0.0.0.0
3. Gateway Address:0.0.0.0
4. XSCF Host Name:
u. Save Configuration
Subnet Mask
Choose "Subnet Mask" in "Network Configuration" menu by number.
Examples:
Network Configuration
1. IP Address:192.168.1.10
2. Subnet Mask:0.0.0.0
3. Gateway Address:0.0.0.0
4. XSCF Host Name:
u. Save Configuration
Gateway Address
Choose "Gateway Address" in "Network Configuration" menu by number.
Examples:
Network Configuration
1. IP Address:192.168.1.10
2. Subnet Mask:255.255.255.0
3. Gateway Address:0.0.0.0
4. XSCF Host Name:
u. Save Configuration
2-5
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 2 Setting Up XSCF
Network Configuration
1. IP Address:192.168.1.10
2. Subnet Mask:255.255.255.0
3. Gateway Address:192.168.1.1
4. XSCF Host Name:
u. Save Configuration
[Next:]
Network Configuration
1. IP Address:192.168.1.10
2. Subnet Mask:255.255.255.0
3. Gateway Address:192.168.1.1
4. XSCF Host Name:scf.foo.com
u. Save configuration
Information
The layout and the content of the menu show a sample. It might be changed because of the
function improvement.
2-6
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
2.2 Specifying the XSCF Settings
In the beginning, select "User Account Administration" from "XSCF Administration" of the
Machine Administration Menu by its number.
Examples:
XSCF Administration
1. Network Configuration
2. User Account Administration
3. Console Administration
4. XSCF Web Administration
5. SNMP Administration
6. Mail Administration
Account setting
To add user account, choose "Add User" in "User Account Administration".
Examples:
2-7
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 2 Setting Up XSCF
[Next:]
Add User
[Next:]
Add user
: Some lines omitted
----------------------------------------------------------------------
Select.(a,q,b,t,h):a [Return]
Enter User Name:abc1234
[Next:]
Select User Group
1. root
2. others
[Next:]
Add User
To add other user account, please repeat the same procedure in "Add User" menu.
2-8
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
2.2 Specifying the XSCF Settings
When the maximum number of account has already been registered, you will see
following screens:
Add User
Delete User
<user> <group>
--------------------------------------
1. xxxx root
2. yyyyy others
3. zzzzz others
4. abc1234 others
[Next:]
Delete User
<user> <group>
--------------------------------------
1. xxxx root
2. zzzzz others
3. abc1234 others
When you press the return key, then the screen is updated as above.
To delete other account, repeate the same procedure.
When no account is registered, you will see following screens:
2-9
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 2 Setting Up XSCF
Delete User
Update Password
To change password, choose "Update Password" from "User Account Administration" menu.
Examples:
Update Password
<user> <group>
---------------------------------------
1. xxxx root
2. zzzzz others
3. abc1234 others
When you press the return key, then it goes back to "Update Password" menu.
To update setting of other account, repeat same procedure.
Information
The layout and the content of the menu show a sample. It might be changed because of the
function improvement.
2-10
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
2.2 Specifying the XSCF Settings
Note:
We strongly recommend that you should set the input-output destination of the OS console to the
tty-a (Especially, when you use the PGX). For more detail about changing the console to "tty-a",
see "Chapter3 Connecting XSCF or Server".
XSCF Administration
1. Network Configuration
2. User Account Administration
3. Console Administration
4. XSCF Web Administration
5. SNMP Administration
2-11
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 2 Setting Up XSCF
6. Mail Administration
Console Administration
[Next:]
Select Standard Console
2-12
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
2.2 Specifying the XSCF Settings
Current configuration: 10
Information
The layout and the content of the menu show a sample. It might be changed because of the
function improvement.
2-13
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 2 Setting Up XSCF
In the beginning, select "Enable/Disable XSCF Web" from "XSCF Administration" menu of the
Machine Administration Menu by its number.
Examples
XSCF Administration
1. Network Configuration
2. User Account Administration
3. Console Administration
4. XSCF Web Administration
5. SNMP Administration
6. Mail Administration
2-14
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
2.2 Specifying the XSCF Settings
[Next:]
Enable/Disable XSCF Web
Current Configuration:disable
1. Enable with read/write mode
2. Enable with read only mode
3. Disable
[Next:]
Enable/Disable XSCF Web
Select Locale
Next, configure "Select Locale" in "XSCF Web Administration" menu.
Examples:
Select Locale
2-15
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 2 Setting Up XSCF
[Next:]
Select Locale
[Next:]
Appearance of Web Page
Access Control
Next, set up "Access Control" in "XSCF Web Administration" menu.
Examples:
Access Control
2-16
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
2.2 Specifying the XSCF Settings
[Next:]
Access Control
1. Host 1:192.168.10.1
a. Add an Access-allowed Host
u. Save Configuration
When you press the return key, then it goes back to "Add an Access-allowed Host" menu.
To specify additional host, repeat same procedure.
You can change the configuration of access-allowed host as follows:
Access Control
1. Host1:192.168.10.1
2. Host2:192.168.10.2
3. Host3:192.168.10.3
a. Add an Access-allowed Host
u. Save Configuration
1. Host1:192.168.10.1
2. Host2:192.168.10.2
a. Add an Access-allowed Host
u. Save Configuration
Information
The layout and the content of the menu show a sample. It might be changed because of the
function improvement.
2-17
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 2 Setting Up XSCF
XSCF Administration
1. Network Configuration
2. User Account Administration
3. Console Configuration
4. XSCF Web Administration
5. SNMP Administration
6. Mail Administration
2-18
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
2.2 Specifying the XSCF Settings
Enable/Disable SNMP
Next, select "Enable/Disable SNMP" in "SNMP Administration" menu.
Examples:
SNMP Administration
[Next:]
Enable/Disable SNMP
Management Information
1. SysContact:name
2. SysName:
3. SysLocation:4-3F ABC
u. Setup Configuration
[Next:]
Management Information
1. SysContact:name
2. SysName:Patty SCF
3. SysLocation:4-3F ABC
u. Setup Configuration
2-19
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 2 Setting Up XSCF
Register Community
Next, select "Register Community" in "SNMP Administration" menu.
Examples:
Register Community
[Next:]
Administration of Community "public"
[Next:]
Administration of Community "public"
[Next:]
SNMP Trap Notification
1. Enable
2. Disable
[Next:]
Administration of Community "public"
Please follow the instructions from menu in order to complete administration of community
"public". Then, you can add second community with using "Register Community" menu.
Examples:
2-20
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
2.2 Specifying the XSCF Settings
Register Community
1. public
a. Add New Community
Delete Community
Select "Delete Community" in "SNMP Administration" menu.
The example of executing the menu of "Delete Community" as follows.
Delete Community
1. public
2. private
[Next:]
Delete Community
1. private
a. Add New Community
Information
The layout and the content of the menu show a sample. It might be changed because of the
function improvement.
2-21
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 2 Setting Up XSCF
Mailing test
After making the settings above, you can conduct a mailing test.
After sending a test e-mail message, confirm that the test message is delivered to the all of the
destination addresses.
In the beginning, choose "Mai Administration" in "XSCF Administration" menu of the Machine
2-22
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
2.2 Specifying the XSCF Settings
Administration Menu.
Examples
XSCF Administration
1. Network Configuration
2. User Account Administration
3. Console Administration
4. XSCF Web Administration
5. SNMP Administration
6. Mail Administration
Mailer setting
Next, choose "Details Setup of the Mail" in "Mail Administration" menu. And enable the "mail
report function".
Examples:
Mail Administration
[Next:]
Details Setup of the Mail
Please follow the instruction of the next screen until the setting is completed.
1. To:
2. From:
3. SMTP Server1:
4. SMTP Server2:
u. Save Configuration
2-23
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 2 Setting Up XSCF
[Next:]
Enable Mail Report (and setup)
1. To:[email protected]
2. From:
3. SMTP server 1:
4. SMTP server 2:
u. Setup execution.
[Next:]
Enable Mail Report (and setup)
1. To:[email protected]
2. From:[email protected]
3. SMTP server 1:
4. SMTP server 2:
u. Setup execution.
[Next:]
Enable Mail Report (and setup)
1. To:[email protected]
2. From:[email protected]
3. SMTP server 1:192.168.1.20
4. SMTP server 2:
u. Setup execution.
Mail address, specify multiple addresses seperated by a comma (,). The total number of
characters cannot exceed 255.
Test Mail
Next, select "Send Test Mail" in "Mail administration" menu in order to conduct a mailing test.
Examples:
2-24
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
2.2 Specifying the XSCF Settings
Information
The layout and the content of the menu show a sample. It might be changed because of the
function improvement.
2-25
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 2 Setting Up XSCF
To check the current configuration in each setting, choose "Show Current Configuration" of
each menu.
2-26
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 3 Connecting XSCF or Server
This chapter explains the procedure for connecting consoles or terminals to have a access to
XSCF, for connecting from UPC or to PC , and for construct RCI network.
Contents:
3.1 Connecting Terminals to XSCF 3-2
3.2 Types of XSCF Connection 3-7
3.3 Connecting XSCF to a PC and UPC 3-9
3.4 Connecting of RCI 3-10
3.4.1 Basic configration 3-10
3.4.2 Cluster Configration 3-11
3.4.3 Method of constructing RCI 3-12
3.5 How to change the input-output destination of OS console to tty-a 3-14
3-1
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 3 Connecting XSCF or Server
The following figure shows the terminal operating modes for connection to XSCF.
Note:
We strongly recommend that you should set the input-output destination of the OS console to the
tty-a (Especially, when you use the PGX). For more detail about changing the console to "tty-a",
see "Chapter3 Connecting XSCF or Server".
3-2
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
3.1 Connecting Terminals to XSCF
As shown in Figure 3-1, the ports that XSCF can be connected are the two ports listed below.
For the output destination of the OS console (standard console),use an XSCF shell command to
select one or the other. The default port when it's shipped from factory is the serial port (tty-a).
The XSCF function operates the same way on both ports. Note, however, that the XSCF Web
function cannot be used on a PC and workstation connected only to the serial port (tty-a) .
● Ethernet
The XSCF shell can be used when telnet on a terminal is connected to Ethernet (LAN
port hereafter). In addition, you can use the XSCF Web function, if enabled, from a web
browser.
The following table lists the types of terminals connected to each port shown in Figure 3-1 and
the port numbers.
Note:
For a single server, since no more than a total of two terminals can be connected at the same
time to the XSCF shell via the serial port (tty-a) and the LAN port, only two users can use the
XSCF shell at the same time.
3-3
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 3 Connecting XSCF or Server
Caution:
When using the XSCF shell simultaneously on the LAN port and serial port, note the following:
● If different power or reset instructions are received from the ports, the previous operation,
such as power-off after power-on, may be canceled.
The procedure described in this section assumes that the XSCF initial settings described in
"Chapter2 Setting Up XSCF" have been completed. For the connections between XSCFA and
PC/workstation with LAN cable, see the User's Manual for the server.
The following is the procedure for connecting to a terminal via the LAN port:
1. Make sure that the LAN cable from the HUB is connected to the SCF-LAN port connector
on the rear of the server. Comfirm the secure connection to the PC or workstation, also.
1) To establish a telnet connection, activate the terminal emulator and specify the IP
address of XSCF and port number 8010.
2) Enter the ID and password to start the XSCF shell.
3) Make sure that the XSCF shell prompt (SCF>) is displayed.
4) The XSCF shell can now be used.
Note:
You can connect to the XSCF shell even when the power of the system is off.
3-4
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
3.1 Connecting Terminals to XSCF
Note:
When you send a Break, the break signal is issued to the server
The following is the procedure for connecting to a terminal via the serial port (tty-a).
1. Make sure that the serial cable is connected to the serial port (tty-a) connector on the rear
of the server and connected securely to the PC or workstation.
1) To use the XSCF shell terminal, enter the keyword, which is a tilde plus a period (~.).
This combination is the default value. For changing the keyword, see "Chapter6
How to Use the XSCF Command Shell".
2) Enter the ID and password to start the XSCF shell.
3) Make sure that the XSCF shell prompt (SCF>) is displayed.
4) The XSCF shell can now be used.
Note:
Even though the server is off, the XSCF shell can be used.
Note:
When you send a Break, the break signal is issued to the server
Switching between "XSCF shell" and "Standard console" (only for serial port)
You can switch the purpose of terminal from "Standard console" to "XSCF shell" or vice versa.
This switching is only valid on serial port (tty-a) connection.
The following is the switching procedure:
1. On the XSCF shell terminal screen, execute the exit command to switch to the standard
console.
2. To switch from the standard console to the XSCF shell, enter a tilde and a period
(~.)(default value).
When XSCF shell terminals and standard consoles are connected to both LAN ports and serial
ports (tty-a) as shown in Figure 3-1, the output destination port of the standard console screen
can be switched with the XSCF command. Since, unlike an XSCF shell terminal, a standard
3-5
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 3 Connecting XSCF or Server
console cannot be used via both ports at the same time, be sure to select one or other of the
ports.
For the XSCF command used to switch ports, see "Chapter6 How to Use the XSCF Command
Shell".
● To change the output destination of the standard console connected via the LAN port to
the serial port (tty-a), use the following procedure:
1. On an XSCF shell terminal that is connected to either port, use the XSCF command to
change the output destination of the standard console to the serial port.
2. From that point, the standard console connected via the LAN port does not display the
console. Make sure that the standard console terminal connected via the serial port (tty-
a) displays the console.
● To change the output destination of the standard console connected via the serial port
(tty-a) to the LAN port, use the following procedure:
1. On an XSCF shell terminal that is connected to either port, use the XSCF command to
change the output destination of the standard console to the LAN port.
2. From that point, the standard console connected via the serial port (tty-a) does not display
the console. Make sure that the standard console terminal connected via the LAN port
displays the console.
Note:
This can be changed on "Console Administration" of the Machine Administration Menu,too.
If the Machine Administration Menu cannot be used or the console cannot be used via LAN
port, please use the Console you can access from PC which is directly connected to XSCF by
serial port (tty-a). Then login to the XSCF Shell and set the console to "serial" with "set-
console-device" command.
3-6
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
3.2 Types of XSCF Connection
XSCF is connected to the SCF-LAN port. The Ethernet connection used for XSCF connection
is shown in Figure 3-1. When XSCF is connected via the LAN, the XSCF functions listed below
can be fully used. For the summary of these functions, see "Chapter1 Overview of XSCF".
The XSCF Web function uses the Secure Socket Layer (SSL) to provide authentication
security.
3-7
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 3 Connecting XSCF or Server
For the security reason, using Virtual Private Network, VPN, as for external network is strongly
recommended.
You can use XSCF by connecting to the serial port (tty-a). The XSCF connection to the serial
port is also shown in Figure 3-1. The following XSCF functions are available when it is connected
to the serial port. Also listed the advantage of such a connection.
Connecting XSCF to both the LAN port and the serial port (tty-a)
XSCF is connected to both the LAN port and the serial port (tty-a). This type of connection is
also shown in Figure 3-1. XSCF, when connected to both ports, has the following advantage in
addition to the functions described for connection to the LAN port:
3-8
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
3.3 Connecting XSCF to a PC and UPC
Use PC I/F when the power supply of the server is turned on from the input-output
device(power supply control box etc.).
Use UPC(UPS I/F) to request shut down of the system promptly from UPS to defend the server
from voltage reduction or black out of commercial power source.
Note:
Power supply control box may not be available in your area due to voltage difference.
3-9
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 3 Connecting XSCF or Server
3-10
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
3.4 Connecting of RCI
The case where two or more servers share disk file unit (File disk Enclosure: FDE) by the SCSI
connection:
By connecting the servers and FDEs with RCI, FDEs are turned on if the server which is turned
on exists. FDEs are turned off when all servers are turned off.
3-11
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 3 Connecting XSCF or Server
Only our trained field engineer allowed to do following RCI related maintenance.
1. Check the present RCI configuration, and the address of the server.
{0} ok rci-config
HOST
address: 000f7f00 mode:20a0 status:00000000
-------------------------------------------------------------------
LIST
address status device-class sub-class
{0} ok rci-config 1 1
Setting server ID=1
{0} ok rci-config-init
Normal End
{0} ok rci-config
HOST
address: 000101ff mode:20a0 status:80000000
LIST
address status device-class sub-class
000101ff 98 0001 0a
003001ff 90 0400 05
003002ff 90 0200 02
002007ff 90 0800 01
{0} ok
3-12
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
3.4 Connecting of RCI
(*1)~(*3) is as follows.
(*1)
[1] bit1 the system reset instruction can be received
(1 : enable to receive)
[2] bit2 the forced power off instruction can be sent
(1 : enable to send)
[3] bit3 Automatic power-on prohibition mode after the forced power off can be set
(1 : unable to start)
[4] bit4 shutdown instruction can be received
(1 : enable to receive)
[5] bit5 shutdown instruction can be sent
(1 : enable to send)
[6] bit6 instruction to turn on power can be received
(1 : enable to receive)
[7] bit7 instruction to turn on power can be sent
(1 : enable to send)
[8] bit13 instruction to turn on power can be received from PC I/F
(1 : enable to receive)
(*2)
[9] bit0-3 the result of configured RCI
(0 : normal / Excluding 0 : abnormal)
[10] bit29 the state of configuring RCI
(1 : now configuring RCI)
[11] bit31 the state of RCI operation
(1 : active)
(*3)
0001: Server
0200: Power controller
0400: Disk file unit
0800: Line switch device
3-13
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 3 Connecting XSCF or Server
"tty-a" should be used as console to access console via SCF-LAN or serial port(tty-a). In
addition to this, ipl-log and panic-log, which is collected by XSCF, is availabe only when output of
console is "tty-a".
To enable XSCF as the Standard console(OS console) device, you must do the following
operation from [1] to [3]:
Note:
When you use the PGX, we strongly recommend that you should do as below.
1. Change the "MAINTENANCE mode" on the MODE SWITCH of the server operation
panel.
2. Power on the server and enter the following commands at the ok prompt on the Console:
ok printenv
input-device ttya
output-device ttya
Therefore, if keyboard and graphic board are mounted on the server, they are used as the
standard console. If not mounted, the options are not valid and ttya is the standard console.
/usr/dt/config/Xservers
3-14
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
3.5 How to change the input-output destination of OS console to tty-a
[3] Stop the port monitor(ttymon) when the console is set to the basic serial port.
[Caution]
After you perfom the operation[2], the result is that CDE screen is not "Console", anymore, so,
you can't log in from this screen by root.
Use following configuration to allow root to sign on from CDE, if needed:
3-15
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 3 Connecting XSCF or Server
3-16
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 4 How to Use the Remote Panel
This chapter describes the Remote Panel that can be used on the XSCF Web function and
explains how to use them.
Contents:
4.1 Overview of the Remote Panel 4-2
4.2 How to Use the Remote Panel 4-4
4.3 LED Indicators on the Remote Panel 4-7
4.4 Differences from the Operating Panel 4-9
4-1
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 4 How to Use the Remote Panel
For information about the XSCF Web function, see "Chapter5 How to Use the XSCF Web
Function".
For information about the operating Panel, see the User’s Manual for the server.
For information about the XSCF shell commands, see "Chapter6 How to Use the XSCF
Command Shell".
Component Description
Indicates the states of the three LEDs:
― POWER LED: Indicates whether the power of the server is
on.
― ONLINE LED: Indicates whether the server has been started
up.
― CHECK LED: Indicates error of the server and the location of
the server.
Indicates one of the three states to which the mode switch is currently
set:
― LOCK mode
― UNLOCK mode
― MAINTENANCE mode
Indicates the states of two LEDs:
― CHECK LED: Indicates a server error and the location of the
Back panel
error.
― SCF Ready LED: Indicates the initial state of XSCF.
Message window Displays a message.
4-2
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
4.1 Overview of the Remote Panel
4-3
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 4 How to Use the Remote Panel
For details of the settings, see "Chapter2 Setting Up XSCF" and "Chapter5 How to Use the
XSCF Web Function".
- Power switch
- Reset switch
- Request switch
- Mode switch (slide switch)
Power switch
Click the power-switch button on the front remote panel to turn server power on and off. When
you turn on the server power, the following events occur:
1) The POWER LED on the front panel light immediately. However, there is a possibility
of not lighting at once according to the setting.
2) The ONLINE LED on the front panel blinks when the power-on sequence has been
successfully completed.
When you turn off the server power, the following events occur:
4-4
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
4.2 How to Use the Remote Panel
the Check LED keep blinking when the trouble has already been found in the server..
Note:
Whenever you control the power from the front remote panel, the Web browser window is
refreshed at intervals of about 10 seconds.
If you cannot power the server on or off using the power switch, do the following:
1) Confirm that the SCF Ready LED on the back panel is green.
Reset switch
Press the reset-switch button on the front remote panel to reset the server.
When you click the reset-switch button, the following events occur:
Note
The reset switch resets the system. Therefore, pushing the reset switch is prohibited for usual
operation. Please push the request switch and execute the crash dump when the system has
been no responses etc or it is necessary to reset the system unavoidably. After the crash dump is
gathered, the system is reset.
Whenever you reset the server, the Web browser window is refreshed at intervals of about 10
seconds.
Resetting the server while the OS is running can damage the disk containing the OS. Use care
when using the reset switch on the front remote panel.
Request switch
Press the request-switch button on the front remote panel to request output of an crash dump to
OS.
Note
The request switch causes the system panic for the crash dump collection. This operation is a
maintenance operation of the system investigation etc. , and has the possibility of destroying the
file system when panic is requested while OS is accessing the file system. Therefore, please do
not operate it, except when it is necessary to gather the crash dump due to the system
investigation purpose or the abnormality such as without the response from the system. The crash
dump might not be able to be gathered according to the state of the system.
Mode switch
The mode switch on the front remote panel indicates the state of the slide switch on the server's
front panel.
Note that you cannot set the mode switch to LOCK, UNLOCK, or MAINTENANCE on the front
remote panel.
4-5
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 4 How to Use the Remote Panel
Viewing messages
The kinds of information listed below are displayed on the remote Panel. For information about
the logs listed below, see "Appendix B XSCF Log Information".
● Error log messages
● Power log messages
● History of panel messages displayed
4-6
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
4.3 LED Indicators on the Remote Panel
- POWER LED
- ONLINE LED
- CHECK LED
- SCF Ready LED
POWER LED
The POWER LED on the front remote panel is green when it is on. Refresh the Web browser
page, then check the POWER LED to determine whether server power is on or off. While
system is working, the POWER LED is green. You can determine the operating status of the
server by checking the POWER LED together with the other LEDs.
ONLINE LED
The ONLINE LED on the front remote panel is green when it is on. When the server has been
turned on, the ONLINE LED lights intermittently until the system successfully completes the
power-on sequence. When the server is turned off, the ONLINE LED also lights intermittently.
Like the POWER LED, the ONLINE LED is green while system is working. You can
determine the operating status of the server by checking the ONLINE LED together with the
other LEDs.
CHECK LED
The CHECK LED on the front remote panel is amber when it is on. The CHECK LED indicates
a server error. Both the CHECK LED on the operating panel and the one on the front remote
panel blink when there is a server error. When server operation is normal, the CHECK LED is off.
You can determine the operating status of the server by checking the CHECK LED together with
the other LEDs.
When more than one same type of system is installed in the same area, it may be difficult to find
out the target system. By checking the CHECK LED, it will be more easier to find target faulty
machine.
In addition to this, by using command on XSCF shell, you can change the status of CHECK
LED to "on" or "blink". And, you may easily find target machine, even when it does not have any
faulty components, by check LED. The remote Panel can also be used to identify the server.
For the XSCF shell commands that are used to check the LEDs, see "Chapter6 How to Use the
XSCF Command Shell".
4-7
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 4 How to Use the Remote Panel
the SCF Ready LED blinks throughout the system power-on sequence. The blinking indicates that
XSCF is being initialized. When the system power-on sequence is completed, the SCF Ready
LED lights. When power is turned off, the SCF Ready LED remains on until the power-off
sequence has been completed. Like the POWER LED and the ONLINE LED, the SCF Ready LED
is green while system is working. You can determine the operating status of the server by
checking the SCF Ready LED together with the other LEDs.
For information about the server status and LED indications, see the User’s Manual for the server.
4-8
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
4.4 Differences from the Operating Panel
4-9
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 4 How to Use the Remote Panel
4-10
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 5 How to Use the XSCF Web
Function
Contents:
5.1 Overview of the XSCF Web Function 5-2
5.2 Starting the XSCF Web Function 5-3
5.3 Logging In to or Out from XSCF 5-4
5.4 XSCF Web Function Pages 5-5
5-1
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 5 How to Use the XSCF Web Function
Page Description
It's a top page of XSCF. Allows users to call the authentication
Top
page. Also allows users to specify XSCF of other server.
5-2
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
5.2 Starting the XSCF Web Function
Prerequisites
The initial settings of the XSCF Web function are disabled by default. To use XSCF Web
function, the following must be specified:
- XSCF account
- IP address of a client terminal
- XSCF Web function mode
- Mail report settings
Supported browsers
Table 5-2 lists the Web browsers supported by the XSCF Web function.
Your Web browser needs functions, listed in the table below, to use the XSCF Web function,
properly. Make sure these settings are enabled.
Browser Version
Microsoft(R) Internet Explorer 5.5 or later
Netscape Navigator(TM) 6.2 or later
Mozilla 1.0 or later
1. SSL (Secure Sockets Layer Protocol) Version 3 / TLS (Transport Layer Security) Version 1
2. JavaScript
3. Cookies
4. Graphic display capability (when graphics mode is used)
5. For Microsoft(R) Internet Explorer, go to "Advanced" tab in "Internet Options" and
uncheck "Display a notification about every script error"
For the URL, specify the IP address or host name assigned to XSCF with root directory.
Example)URL https://xxx.xxx.xxx.xxx/
Alternatively, https://XSCF-host-name (Note: This is not a host name of Solaris OE.)/
Note:
When the communication begins, a browser might request the confirmation of the certificate.
Please you must confirm the content and accept the certificate at that time.
5-3
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 5 How to Use the XSCF Web Function
Logging in to XSCF
To connect to the XSCF Web function pages, log in to the XSCF top page. If login is successful,
the index page is displayed. If login fails, a message indicating that login failed is displayed.
When failure of the log in satisfy the following condition, the failure is
reported by mail to the system administrator.
a. XSCF users with the same account attempt to access any XSCF Web pages, and more
than five attempts failed within 3minutes due to authentication failure.
To use the mail report function, register a destination address for the mail in advance. For
information about specifying the destination address, see "Chapter2 Setting Up XSCF".
The XSCF Web function monitors the accounts of XSCF users who are logging in to XSCF. If
login to XSCF has been successful but no access is made for a certain time, an authentication
timeout occurs and the XSCF Web function logs the user out. If an attempt is made to access
the XSCF Web function after a timeout, a dialog box reporting an authentication timeout is
displayed. The top page is then displayed. To use the XSCF Web function again, log in to
XSCF again.
The authentication timeout setting can be changed. For details of specifying the
authentication timeout setting, see "Chapter2 Setting Up XSCF".
To exit the XSCF Web function, log out from XSCF on the index page. If you do not log out and
simply terminate the XSCF Web function connection, you may not be able to log in to XSCF again
from the same account for a certain time.
Attempt of login after authentication timeout will be refused with following condition and period:
● Condition
― Case1: The cookies is deleted.
― Case2: You try to login to an another browser.
● Time during which login refused
The maximum time during which login will be refused is determined by the authentication
timeout setting.
For example, if 30 minutes is specified as the timeout setting and if you have accessed
XSCF for 10 minutes when you terminate the connection, you will not be able to access
XSCF for 20 minutes.
The maximum timeout setting is 255 minutes.
5-4
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
5.4 XSCF Web Function Pages
● Logs
― Error log
― Power log
― Remote panel message history
● Other features
― Changing of the password
Allows you to change the password assigned to an XSCF account used to log in to
XSCF. For the restrictions on the password, see "Chapter2 Setting Up XSCF".
5-5
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 5 How to Use the XSCF Web Function
5-6
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2003
Chapter 6 How to Use the XSCF
Command Shell
Contents:
6.1 Overview of XSCF Command Shell 6-2
6.2 Login to XSCF User Account 6-4
6.3 Server Status and Control Commands 6-6
6.4 XSCF Log View Command 6-13
6.5 XSCF Server Configuration Information Command 6-21
6.6 Other XSCF Commands 6-25
6.7 XSCF Shell Error Messages 6-28
6-1
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 6 How to Use the XSCF Command Shell
6-2
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
6.1 Overview of XSCF Command Shell
Note:
There are two user authority levels, which are explained below. For information about setting
the user authority, see "Chapter2 Setting Up XSCF".
― root: Root-level authority. All XSCF shell commands can be used.
― others: Authority other than root level. Only some of the XSCF shell commands
can be used.
6-3
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 6 How to Use the XSCF Command Shell
Before login
The following explains how to log in from a terminal connected to the serial port (tty-a).
1. From the console immediately after the port connection, input the keyword (~.) (tilde |
period: it's default value.) to enter the XSCF console.
2. After having entered the XSCF console, input the user ID and password that have been
registered from the Machine Administration Menu.
After login to the account, the XSCF shell prompt (SCF>) appears, so use the XSCF
commands. The following is an example of command execution.
~.
SCF Shell
login:root
Password:
SCF Version xxxxxxxx
ALL RIGHTS RESERVED, COPYRIGHT (C) FUJITSU LIMITED 2003
[11.22.333.444]
SCF>
The following explains how to log in to the XSCF shell using the SCF-LAN (telnet).
1. Specify the IP address and port number 8010 for the XSCF shell and execute telnet via
6-4
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
6.2 Login to XSCF User Account
the SCF-LAN.
2. On the XSCF console, enter the user ID and password.
After login to the account, the XSCF shell prompt (SCF>) appears, and XSCF commands can
be entered.
Use lan-config command to display the configuration information of the SCF-LAN.
The following is an example of command execution.
~.
SCF Shell
login:root
Password:
SCF Version xxxxxxxx
ALL RIGHTS RESERVED, COPYRIGHT (C) FUJITSU LIMITED 2003
[11.22.333.444]
SCF>
In case any Alarm or Warning level fault has been detected, error messages are displayed
following to typing SCF Shell Keyword. This error messages are displayed only when the mode
switch on the front panel is placed to maintenance position.
SCF Shell
login:
Note:
These messages are displayed even when no XSCF accounts are registered. In case you have
faced any problem, and you cannot login to XSCF due to any reason, such as no XSCF account,
fix the problem with refering this message.
6-5
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 6 How to Use the XSCF Command Shell
- env-monitor
- net-status
- nodeled
- show-status
- show-console-device
- set-console-device
- xir
- por
- shutdown
- request
- power-off
- power-on
env-monitor value
The env-monitor command is used to view the server status. For example, it can be used to
display the temperature, CPU state, and power supply state. When no options are specified,
major information is displayed.
The following is an example of command execution.
SCF> env-monitor
------------------------
INLET Temperature 28C
------------------------
CPU
No. Temp Status DDC-Voltage DDC-Status
--- ---- -------- ----------- ----------
#0: 31C O.K 1.31V O.K
#1: 30C O.K 1.33V O.K
------------------------
System Board
SB: Temperature0 36C Temperature1 27C
SB 12V: 11.99V SB-12V: -12.26V SB5V: 5.06V
SB 3.3V: 3.34V SB2.5V: 2.65V SB1.8V: 1.77V
SB1.25V: 1.32V
------------------------
FAN
FAN#0: rotate state 3660rpm
FAN#1: rotate state 3960rpm
FAN#2: rotate state 3720rpm
FAN#3: rotate state 3960rpm
FAN#4: rotate state 4080rpm
FAN#5: rotate state 3720rpm
------------------------
PSU
PSU#0: Mount Status:Alarm
6-6
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
6.3 Server Status and Control Commands
scsibpn (n =0.1) Displays the status, running days, and error messages for each SCSI
board.
psun (n =0.1.2) Displays the status, running days, and error messages for each PSU.
slotn (n =0.1..15) Displays the status and error messages for each slot (DIMM).
fann (n =0.1..7) Displays the status, rotation speed (rpm), rotation status (high/low),
and error messages for each fan.
ddcan (n =0) Displays the DDC-A status and 1.8 V voltage value.
ddcbn (n =0) Displays the DDC-B status and 2.5 V voltage value.
power-control Displays whether the scheduled power control, APCS, is enabled and
the time that is set.
net-status
The net-status command is used to view the SCF-LAN network status. For example, it can be
used to display the connection state, Ethernet data transfer rate, and Number of Send-Receive
packet.
The following is an example of command execution.
SCF> net-status
*** SCF-LAN Network Status ***
Connection : online
Speed : 100Mbps (half duplex)
Send Packets : 2818
Receive Packets : 23983
6-7
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 6 How to Use the XSCF Command Shell
The nodeled command is used to display the status of each LED on the front and back panel of
the server. In addition, you can make CHECK LED turn on or blink in order to locate the
target system. After found the location, you can free the state of CHECK LED by this
command.
When no option is specified, the command shows the status of all LEDs, (POWER LED,
ONLINE LED, CHECK LED, and SCF Ready LED).
In the addition, as described above, this command can be used to locate the target system. For
example, when more than one same type of system is installed in the same area, it may be
difficult to find out the target system. By specifying -mode option to this command, you can
change the state of CHECK LED to specified state. With help of CHECK LED, you may be able to
locate the target system, easier. After found location, cancel the forced state of CHECK LED by
specifying -mode off option.
Note that the -mode and -status options are mutually exclusive.
For more information about the panel LEDs, see the User's Manual for the server.
The following is an example of executing a command that first causes the CHECK LED to blink
and then cancels the action.
Option Description
6-8
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
6.3 Server Status and Control Commands
show-status
show-status command provides fault factors to blink Check LED except blinked by nodeled
command.
SCF> show-status
CPU#0 Alarm
show-console-device
The show-console-device command on the XSCF console is used to display whether the
current destination of the server OS console is on the SCF-LAN or is the serial port (tty-a).
The following is an example of command execution.
SCF> show-console-device
TTY-A Port : serial
SCF>
Note:
We strongly recommend that you should set the input-output destination of the OS console to the
tty-a (Especially, when you use the PGX). For more detail about changing the console to "tty-a",
see "Chapter3 Connecting XSCF or Server".
The set-console-device command in the XSCF console is used to set the current destination of
the server OS console to either SCF-LAN or serial port (tty-a). Since there are no functional
differences between the choices, the appropriate choice for the user's requirements can be
selected. Using this command without the option results in an error. The required authority for
this command is root level.
The following is an example of executing the command to set the SCF-LAN port.
6-9
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 6 How to Use the XSCF Command Shell
SCF> show-console-device
TTY-A Port: serial
SCF> set-console-device lan
SCF> show-console-device
TTY-A Port: lan
SCF>
Option Description
Note
This can be changed on "Console Administration" of the Machine Administration Menu,too.
If the Machine Administration Menu cannot be used or the console cannot be used via LAN
port, please use the console you can access from PC which is directly connected to XSCF by
serial port (tty-a). Then login to the XSCF Shell and set the console to "serial" with this
command.
who
The who command can list the user’s name, terminal line and login time.
The following is an example of command execution.
SCF> who
plato Serial(RS232C) 2002/12/03 02:20:14 ---
root Telnet(port 8010) 2002/12/03 02:13:27 11.22.333.444
SCF>
xir
The xir command generates an externally initiated reset (XIR) of the server. The server OS
console prompt changes to ok. The required authority for this command is root level.
Note
Please use this command only when you cannot stop your system in normal procedure due to
any software or hardware trouble.
Do NOT use this command on normal working system. For normal working system, please use
"shutdown" command.
WARNING
File system could be damaged by executing this command during OS is working.
6-10
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
6.3 Server Status and Control Commands
shutdown
The shutdown command generates to shut down the server. This command is ignored when
executed during power-off or a reset. The required authority for this command is root level.
por
The por command is used to perform an immediate system reset of the server. The required
authority for this command is root level.
Note
Please use this command only when you cannot stop your system in normal procedure due to
any software or hardware trouble.
Do NOT use this command on normal working system. For normal working system, please use
"shutdown" command.
request
The request command is used to send a panic instruction to the OS. The operation performed
is the same at that performed when the request switch on the operating panel or remote panel is
pressed. This command is ignored when executed during power-off, a reset, or shutdown. The
required authority for this command is root level. For information about an OS dump, see the
Machine Administration Guide for the ESF.
The following is an example of command execution.
SCF> request
SCF>
Note
"request" command causes the system panic to collect the memory dump. Purpose of this
command is only for maintenance, such as, to investigate hangup of system. Therefore, please
do NOT execute this command, except when it is surely necessary.
WARNING
File system could be damaged by executing this command during OS is working.
power-off
The power-off command is used to power off the server. This command is ignored if used
when server power is off. Note that this command does not affect the power, supplying to
XSCF. The required authority for this command is root level.
Note
Please use this command only when you cannot stop your system in normal procedure due to
any software or hardware trouble.
Do NOT use this command on normal working system. For normal working system, please use
"shutdown" command.
WARNING
6-11
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 6 How to Use the XSCF Command Shell
power-on
The power-on command is used to power on the server. This command is ignored if used
when the server power is on. Note that the command does not affect the XSCF power supply.
The required authority for this command is root level.
6-12
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
6.4 XSCF Log View Command
- show-error-logs
- show-power-logs
- show-event-logs
- show-console-logs
- show-access-logs
- thermal-history
- show-device-records
- show-ipl-logs
- show-panic-logs
show-error-logs
The show-error-logs command is used to view the summary of errors or notification that have
been detected by XSCF and OBP. The log information can be viewed when a system error
such as a reset error, failed OS startup, error indicated by blinking of CHECK LED on the front or
back panel of the server, or slow down of process on Solaris OE has occurred. The same
error log information is also retained by the Machine Administration Menu. For the logging
information retained by the Machine Administration Menu, see the Machine Administration Guide
for the ESF. The maximum number of log entries is 32.
Component Description
"No" indicates the sequence number assigned to the error to be
No/Error Count displayed. "ErrorCount" indicates the total number of errors to be
displayed.
Date Indicates the time (local time) that the error occurred.
The system fault level of the error. The levels are ALARM,
SysDamage
WARNING, and NOTICE.
FaultDetect Indicates the hardware where the error was detected.
6-13
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 6 How to Use the XSCF Command Shell
SCF> show-error-logs
***** No.01/32
Date = 2002/08/31 08:25:39
SysDamage = NOTICE
FaultDetect = SCF
FaultCode = 430102FF
DetailInfo = FAN speed low CAUSE: temperature lower
ReplaceParts = ---
Syslog msg = Notification
00831810 430102FF 02083108 2539FFFF
494E4C45 54207468 65726D61 6C206C6F
77204641 4E207370 65656420 6C6F7700
171A0000 00000000 00000000 00000000
:
:
SCF>
Note:
Some of the errors detected by the OS may not be displayed.
show-power-logs
The show-power-logs command is used to view all information in the power log, including any
server power-on, power-off, or reset detected by XSCF and POST/OBP. The information can be
viewed for use in investigating circumstances of use when a system error has occurred. The
same power log information is retained by the Machine Administration Menu. For the logging
information retained by the Machine Administration Menu, see the Machine Administration Guide
for the ESF. The maximum number of log entries is 32.
The following shows the format of a line in the power log.
For a list of power logs and a fuller explanation, see "Appendix B XSCF Log Information".
The following is an example of command execution.
SCF> show-power-logs
DATE TIME TYPE FACTOR DETAIL MSW
----------+--------+-----------------+-----------+---------+----
2002/08/07 15:02:58 20:Power-on 80:UPS 01 000000 M
2002/08/07 15:03:03 3f:Reset-Release 00:--- 00 000000 M
6-14
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
6.4 XSCF Log View Command
show-event-logs
The show-event-logs command is used to view all event logs that have been created on the
server, such as those recording operator events and the reporting of events from the OS. The
information can be viewed to determine the operating status of the server as an aid to
investigating a system error and to changing the system configuration. The same event log
information is retained by the Machine Administration Menu. For the logging information
retained by the Machine Administration Menu, see the Machine Administration Guide for the ESF.
The maximum number of log entries is 256.
The following shows the format of a line in the power log.
For the list of event logs and meanings, see "Appendix B XSCF Log Information".
The following is an example of command execution.
SCF> show-event-logs
DATE TIME MSW Address FACTOR DETAIL
---------+--------+---+--------+----------+----------------------------------
2002/08/08 11:43:59 M 000F7F00 60:SysInfo 00000000 00000000 00000000 00000000
6-15
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 6 How to Use the XSCF Command Shell
The show-console-logs command is used to view the console output logs on the server console.
A log contains the logging data output from the OS to the console and can be used for
investigating usage conditions for system error or other problem. The latest 16 KB of logging
information can be viewed.
The following is an example of command execution.
SCF> show-console-logs
100.00000000
0> Probing U2P#3(0x83) at 106.00000000
0> U2P Registers Test
0> IO0_Status= 01000000(MC0Q=2), UPA_Config=00000002
0> Testing U2P port_id=80
0> IO3_Status= 01000000(MC0Q=2), UPA_Config=00000002
0> Testing U2P port_id=83
0> U2P Interrupts Test
0> Testing U2P#3(portid=83,inr=20ee)
0> Testing U2P#3(portid=83,inr=20ef)
0> Testing U2P#3(portid=83,inr=20f0)
SU,sppex
Omitted
4x SPARC64 V , No Keyboard
OpenBoot 3.1.0-16, 16384 MB memory installed
Ethernet address 0:e0:0:c4:80:3, Host ID: 00000000.
SCF>
Description Description
-d: Display the log with logged date.
-d –t -t: Display the log with logged time.
Ommitting this opiton, display the log only.
Display the log of specified size. Value has to be designated in
hexadecimal format.
-s
Ommitting this option, display 8KB size log.
Maximum 16KB can be
show-access-logs
The show-access-logs command is used to view the logs recording access to the XSCF Web
function pages, XSCF shell, or any other XSCF function. Any access to XSCF, such as,
a user check system status on XSCF web, or a user uses XSCF shell via serial port
(tty-a) or LAN (telnet), is logged. This information can be used for security purposes to
investigate usage conditions for an unauthorized access and to investigate system errors. The
maximum number of log entries is 42.
The following shows the format of a line in the access log.
6-16
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
6.4 XSCF Log View Command
― DATE : Date on which a network port such as the XSCF Web function or SCF-
LAN port was accessed
― TIME : Time (local time) when s network port such as the XSCF Web function or
SCF-LAN port was accessed
― User ID
― Accessed port ID
― User IP address
SCF> show-access-logs
Date TIME ID TYPE IP address
---------+---------+------+-----------------+----------------
2002/09/10 09:18:52 user01 Telnet(port 8010) 11.22.33.4
2002/09/12 09:18:52 guest Telnet(port 8010) 123.123.123.123
2002/09/14 09:18:52 root Serial(RS232C) ---
2002/09/15 09:18:52 user01 SSL(Port 443) 11.22.33.4
SCF>
Note:
The TYPE values include telnet, SNMP, RS232C serial, SSL, and http.
The thermal-history command is used to view a history of the ambient server temperature, CPU
temperature, and temperature of the system board. When the -g option is specified, the history
is represented graphically. When no options are specified, all temperature histories are listed in
a table. To display the temperature history for each device, enter the specification option in the
table given below.
The logged information can be remains for about one day. Older information will be expired.
Therefore, you can view the log information of latest one day.
The information can be used for investigating the server environment for a system error or
other problem.
The following shows the format of a line in the temperature history.
SCF>thermal-history
6-17
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 6 How to Use the XSCF Command Shell
SCF>thermal-history cpu0
Thermal History cpu0[ Celsius]
_GMT__|___00___10___20___30___40___50[ MIN]
01:10 | --- OFF OFF OFF OFF OFF
02:00 | OFF OFF 029 030 030 030
03:00 | 030 030 031 031 031 031
04:00 | 032 032 032 032 033 033
05:00 | 033 033 034 034 034 035
06:00 | 035 035 035 035 036 036
07:00 | 036 036 036 036 036 036
08:00 | 037 037 037 037 037 037
09:00 | 037 037 037 037 037 037
10:00 | 037 037 037 037 037 036
11:00 | 036 035 035 035 034 034
SCF>
Option Description
Optional. The temperature history information is represented
graphically. If this option is not specified, the information is
-g
presented in table form. When -g is specified but value is not
specified, the command results in an error.
Options for value
Note:
If the power plug is disconnected, all temperature history information will be lost.
6-18
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
6.4 XSCF Log View Command
This information can be used to investigate the server status when the system was started.
The following is an example of command execution.
SCF> show-ipl-logs
0>Flash/SRAM Test
0> Flash Memory check sum Test
0> FROM#0 checksum = 110a8bf4
0> FROM#1 checksum = 112e489f
0> SRAM Data Line Test
0> SRAM Addr Line Test
0> SRAM Data Test
0> SRAM Init Test
0>SC Test
0> SC init
0>SCF Test
0> SCF Test
0> CPU Status Test
:
:
:
OpenBoot 3.1.0-18, 1024 MB memory installed
Ethernet address 0:ee:0:dd:88:22, Host ID: 11223344.
SCF Version: 0.1.0000
board
RCI is not configured
{0} ok
SCF>
Description Description
-d: Display the log with logged date.
-d –t -t: Display the log with logged time.
Ommitting this opiton, display the log only.
-f: Display the log starting from the latest.
-f –b -b: Display the log starting from the oldest.
Ommitting this opiton, display the log starting from the latest.
Display the log of specified size. Value has to be designated in
hexadecimal format.
-s
Ommitting this option, display 8KB size log.
Maximum 16KB can be
The show-panic-logs command is used to view the logging information of the last panic.
The following is an example of command execution.
SCF> show-panic-logs
6-19
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 6 How to Use the XSCF Command Shell
Description Description
-d: Display the log with logged date.
-d –t -t: Display the log with logged time.
Ommitting this opiton, display the log only.
-f: Display the log starting from the latest.
-f –b -b: Display the log starting from the oldest.
Ommitting this opiton, display the log starting from the latest.
Display the log of specified size. Value has to be designated in
hexadecimal format.
-s
Ommitting this option, display 8KB size log.
Maximum 16KB can be
Note:
This log can be shown only when OS console port is set to the SCF-LAN port or the serial
port(tty-a).
6-20
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
6.5 XSCF Server Configuration Information Command
- date
- rci-config
- show-config
- lan-config
date
The date command is used to display the current time and date. The time cannot be
specified.
The following shows the format of one line.
― yyyy : Year
― mm : Month
― dd : Day in the month
― HH : Hour (24-hour system)
― MM : Minute
― SS : Second
― TimeZoneName : Display the name of the local time zone (Maximum 8 charactors)
SCF> date
2002/08/13 11:41:40 JST
SCF>
Note:
The date and time displayed by the date command are local time.
Time cannot be set from the XSCF shell. Please use and set the command of Solaris OE such
as Date. When the utility of Solaris OE which controls the time such as NTP is used, the calendar
timer of XSCF receives the influence. Please refer to the manual of relating Solaris OE for details.
rci-config
The rci-config command is used to view the RCI configuration information. You may want to
check the status of RCI by this command when, for example, you are setting up the system or
you change the configuration of system. For details of the RCI configuration information, see
"Chapter 3 Connecting XSCF to Terminal". The Machine Administration Menu also displays the
RCI network list information. For the RCI configuration information displayed by the Machine
Administration Menu, see the Machine Administration Guide for the ESF.
The following shows the format of the host address display and of the RCI configuration in the
RCI configuration information.
6-21
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 6 How to Use the XSCF Command Shell
HOST
$Address $Mode $Status
LIST
$address $status $device-class $sub-class
SCF> rci-config
HOST
Address:000101FF Mode:20A0 Status:80000000
LIST
Address Status Device-Class Sub-Class
000101FF 99 0001 0A
000102FF 98 0001 07
003001FF 90 4000 05
SCF>
show-config value
The show-config command is used to view the system information, number of server CPUs,
You may want to check the status of the
memory capacity, part information, and the like.
system by this command when, for example, you are setting up the system or you
change the configuration of system.
When no option is specified, a synopsis of the configuration information for the device is
displayed.
The following is an example of command execution.
SCF> show-config
--------------------
Model name : PWPL-450
Model type : XXXXXX
Machine Versio n : 12
Sysytem frequency: 220MHz
Version : 001AA
SB Type : 0102
-------------------------
CPU No. Frequency Serial-no.
6-22
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
6.5 XSCF Server Configuration Information Command
scf Displays the XSCF firmware version, RCI version, and server ID.
pcin (n =00.01..08) Displays the information for each PCI slot. n is a two-digit number.
scsibpn (n =0.1) Displays the serial number, part number, and version of each SCSI
board.
diskn (n =0.1..5) Displays the vendor, product name, version, and serial number of
each disk.
psun (n =0.1.2) Displays the serial number, part number, and version of each PSU.
slotn (n =0.1..15) Displays the serial number, part number, version, and capacity of each
slot (DIMM).
fann (n =0.1..7) Displays the serial number, part number, and version of each fan.
lan-config
The lan-config command is used to view the current configuration information for the SCF-LAN.
SCF> lan-config
6-23
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 6 How to Use the XSCF Command Shell
6-24
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
6.6 Other XSCF Commands
- exit
- help
- show-shell-command
- set-shell-command
- version
exit
SCF> exit
logout
help
The help command is used to display alphabetically a list of shell commands available in the
XSCF shell.
The following is an example of command execution.
SCF> help
COMMAND DESCRIPTION
---------------------------------------------------------------------------
date Show date.
env-monitor Show system environment.
exit Exit XSCF Shell.
help Show help of shell command.
lan-config Show LAN configuration.
net-status Show SCF-LAN status.
nodeled Show and Control Check LED status.
por por,Powrer On Reset.
power-on Power on.
power-off Power off.
rci-config Show RCI configuration.
request Panic request.
set-console-device Set console device [serial | lan]
set-shell-command Change shell keyword.
show-access-logs Show the access logs.
show-config Show system configuration.
show-console-device Show console device setting as TTYA Port.
show-console-logs Show console messages.
show-error-logs Show error logs.
show-event-logs Show event logs.
show-ipl-logs Show IPL,Initial Program Loading, messages.
show-panic-logs Show Panic messages.
6-25
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 6 How to Use the XSCF Command Shell
show-shell-command
The show-shell-command is used to display a login keyword that can move to the XSCF shell
terminal from the Standard console.
The required authority for this command is root level.
The following is an example of command execution.
SCF> show-shell-command
Shell keyword code :~.
ASCII CODE :7E2E
SCF>
set-shell-command
The set-shell-command is used to change a login keyword that can move to the XSCF shell
terminal from the Standard console.
The default value is a tilde plus a period (~.). This can be changed on the command of
Machine Administration function,too. This can be changed to a combination of up to seven
characters. The required authority for this command is root level.
The following is an example of command execution.
Note:
The following is a reference of the command on the Machine Administration function.
scfshkey (1M)
NAME
scfshkey - Display and change the login keyword for XSCF shell.
SYNOPSYS
/usr/sbin/FJSVmadm/scfshkey
/usr/sbin/FJSVmadm/scfshkey set <keyword>
DESCRIPTION
The scfshkey command displays and changes the login keyword to move the control
from the standard console to the XSCF shell.
OPTION
6-26
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
6.6 Other XSCF Commands
set <keyword>
specifies a new keyword.
The <keyword> specifies a string, which consists of alphabetic, numeric or special
character. Its length is 1-7 characters.
When the OPTION is ommited, scfshkey displays the current value of the login keyword.
EXIT STATUS
The following status is returned.
0 : normal end
>0 : an error occurred
version
The version command is used to display the firmware version information of the XSCF and
OBP. The following is an example of command execution.
SCF> version
*** XSCF Firmware Information ***
XSCF Version ---------- [E02V03L01]
WEBDATA Version ------- [E02V03L01]
RASDB Version --------- [E02V02L01]
*** OBP Information ***
OBP Version ----------- [E02V03L01]
*** HCP Information ***
Current Version ------- [HCP0201]
*** Hardware Information ***
RCI Version ----------- [0001]
SCF>
6-27
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 6 How to Use the XSCF Command Shell
When an XSCF shell command is used incorrectly, an error message is displayed. The
following table lists the error messages displayed and explains their meaning.
6-28
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 7 XSCF SNMP Agent Function
Contents:
7.1 Summary of XSCF SNMP Agent Function 7-2
7.2 About MIB 7-3
7.3 About Traps 7-4
7.4 How to Set up the XSCF SNMP Agent Function 7-5
7.5 Introduce Extended MIB of XSCF to SNMP Manager 7-6
7.5.1 Installation case to WebSysAdmin 7-6
7.5.2 Installation case to SystemWalker 7-8
7-1
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 7 XSCF SNMP Agent Function
SNMP is a protocol for network management. The SNMP manager enables integrated
management of the operating status and fault status of the terminals in the network. The SNMP
agents return management information referred to as MIB (Management Information Base) in
response to the SNMP manager's request.
For specific kinds of information, the agents can use the TRAP function to send asynchronous
notifications to the SNMP manager .
Note:
Several kinds of SNMP manager may be available. For example, Web SysAdmin, WSA,
software is available from us.
7-2
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
7.2 About MIB
● Standard MIB
XSCF supports MIB-II, the Internet standard, which manages several issues like follows:
For a list of standard MIBs supported by XSCF, see "Appendix C.2 Standard MIB".
In addition to the standard MIB, XSCF supports the Fujitsu extended MIB, which is an
extension for the XSCF SNMP agent. The Fujitsu extended MIB primarily manages the
following kinds of information:
For the list of Fujitsu extended MIBs supported by XSCF, see "Appendix C.3 Fujitsu Extended
MIB".
Note:
The MIB file can be refferred to from the following path in the HCP-CD, too.
/PWP0/MIB
7-3
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 7 XSCF SNMP Agent Function
7-4
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
7.4 How to Set up the XSCF SNMP Agent Function
● Step 1:
Make sure that the XSCF SNMP agent function is disabled.
― If the function is enabled, disable it.
Note:
Be careful when disabling an enabled SNMP agent function, since all MIB information,
except the configuration information specified by Step 2, will be initialized
● Step 2:
Make the necessary settings for the XCSF SNMP agent function:
― XSCF manager
― Server name
― Server location
― Community information 1 or community information 2
Note:
For the community information, either 1 or 2, or both 1 and 2 can be specified.
Specifying no community information is not allowed.
In the settings for community information, you can specify whether to enable write
operations to the writable MIB and whether to enable the issuing of traps.
● Step 3:
Enable the XSCF SNMP agent function.
Note:
If you modify the XSCF SNMP agent function settings, be sure to start at the beginning
with step 1.
7-5
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 7 XSCF SNMP Agent Function
This work must be done with the workstation in which WeabSysAdmin is installed.
● Step 1:
Make the temporary directory (In this example, "/tmp/primepower_xscf"), and copy
XSCF extended MIB infomation file from the directory in which XSCF extended MIB
# mkdir /tmp/primepower_xscf
# cd /tmp/primepower_xscf
# cp /opt/FJSVhcp/mib/primepower_xscf.dat ./
#
is installed.
● Step 2:
Backup the current MIB information file to the file that you specified.
(In this example, "/etc/snmp/mgr/snmpinfo.dat.bak")
# cp /etc/snmp/mgr/snmpinfo.dat /etc/snmp/mgr/snmpinfo.dat.bak
#
● Step 3:
Merge XSCF extended MIB information file with current MIB information file by the
command "mergeinfo". When you face any warning or error messages from
mergeinfo, go to Step 5.
# /opt/SMAW/bin/mergeinfo primepower_xscf.dat
#
● Step 4:
If file /etc/snmp/mgr/snmpinfo.dat is updated, and new MIB information is added
to the content, the installation work is completed.
● Step 5:
When there is message of this command in the merging work,
merging has not ended normally.
7-6
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
7.5 Introduce Extended MIB of XSCF to SNMP Manager
Here, a typical message of the merging command and the action method of the message is
shown as follows.
# /opt/SMAW/bin/mergeinfo primepower_xscf.dat
/opt/SMAW/bin/mergeinfo:check_names:
Duplicate name with different OID's:rfc1157Domain
OID1: 1.3.6.1.6.2.1.1, OID2: 1.3.6.1.3.11.3.1.1
#
7-7
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 7 XSCF SNMP Agent Function
● Step 1:
Start the application of "System Monitor" of SystemWalker, and click in the
following order.
"Tools" menu → "Extend MIB".
● Step 2:
Click "Add" button of "Extend MIB" dialog box.
● Step 3:
Select extended MIB file of XSCF in "Select of Extend MIB file" dialog box.
Selected extend MIB compilation is begun. When the compilation is completed, "Extend
MIB" dialog box is displayed.
● Step 4:
Click the “OK" button in "Extend MIB" dialog box .
● Step 5:
Close "Extend MIB" dialog box.
● Step 6:
Start "MS command prompt", and execute the following command.
Name of the directory used here must be different from your environment. Please
specify your using directory.
******************************************
******************************************
Processed definitions : 7
******************************************
C:¥>
7-8
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
7.5 Introduce Extended MIB of XSCF to SNMP Manager
● Step 7:
Click as follows in the application "System Monitor" of SystemWalker.
● Step 8:
Select "Apply immediately (Restart distribution destination service)" in "Policy
Distribution" dialog box, and click “OK".
● Step 9:
"Policy Distributing Status" dialog ends automatically when
the distribution of the policy ends.
Next, a setup which calls "XSCF WEB function" from SystemWalker is performed.
● Step 10:
Click in the following order on "System Monitor" windows of SystemWalker.
● Step 11:
Select "Single System" and click "Add..." button.
"Single System(Add)" dialog box is displayed.
● Step 12:
Set the following items, and click “OK" button.
[ Command Line ]
"C:¥Program Files¥Internet Explorer¥iexplore.exe" https://%IP
(This is a example. Please set a browser used. )
"Add Operation Menu" message box is displayed.
● Step 13:
Click “OK" button.
"Add Operation Menu" dialog box close.
● Step 14:
Reboot the "System Monitor" of SystemWalker.
● Step 15:
We will be able to use new menu item "XSCF WEB" by the following methods.
"Tools" menu → "Specific Node(System)" item → "XSCF WEB" item
"XSCF WEB" is started on a specified browser.
7-9
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 7 XSCF SNMP Agent Function
7-10
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 8 XSCF Mail Function
Contents:
8.1 Overview of XSCF Mail Function 8-2
8.2 Reporting Parts Faults 8-4
8.3 Reporting an Authentication Failure 8-5
8.4 Setting up the XSCF Mail Function 8-6
8.5 Contents of Parts Fault Notification 8-7
8.6 Contents of Authentication Failure Notification 8-9
8.7 Contents of Test Mail Notification 8-10
8.8 Contents of Suspension Mail Notification 8-11
8-1
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 8 XSCF Mail Function
Note:
Single problem may cause two separate e-mail messages, one from the machine
administration and one from XSCF. For more definite and complete detection of errors,
Enabling the mail notification of both functions, machine administration and XSCF, is
recommended.
8-2
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
8.1 Overview of XSCF Mail Function
The following is the e-mail notification method. Setting is performed from the Machine
Administration Menu.
Note:
For information about the SMTP server settings, see "Chapter2 Setting Up XSCF".
8-3
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 8 XSCF Mail Function
XSCF monitors the parts in the server (including the CPU, fan, and system board). If an error
occurs for any of these parts, XSCF sends an e-mail notification to the system administrator.
In the following figure, XSCF reports parts faults to the system administrator by mail.
8-4
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
8.3 Reporting an Authentication Failure
8-5
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 8 XSCF Mail Function
● Step 3: Specify the following information for the XSCF mail settings:
― Specify the IP address of the SMTP server.
― Specify the mail address of the system administrator as the mail destination.
― Specify From information.
Note:
The IP address of the SMTP server and the From information can be omitted.
8-6
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
8.5 Contents of Parts Fault Notification
The following describes how to read the contents of the mail shown in Figure 8-4.
1. Mail address specified for the From designation in the mail settings.
2. Mail address specified as the destination mail address in the mail settings.
For the above settings , see "Chapter2 Setting Up XSCF".
3. Host name of XSCF.
4. Fault level of the faulty part, which is one of the following:
― A: Fault or abnormal condition (Alarm)
― W: Part degraded or warning (Warning)
― I: Notification (Information)
5. Faulty part (n indicates the part number). The types of parts are listed below. For
information about part names, see "Glossary".
SB, PANEL, PCI-BD, CPU#n, CPU-DDC#n,
SLOT#n, PSU#n, UPS, FAN#n, FAN-JT#n,
DDC-A#n, DDC-B#n, and SCSI-BP#n
6. Hardware unit where the fault was detected
SCF
POST
OBP
7. Message output by the system. For the meaning of messages, see "Appendix A Warning
Messages".
8. Time at which the fault occurred. The time is the local time.
9. Error code. For the error codes, see "Appendix B XSCF Log Information".
8-7
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 8 XSCF Mail Function
8-8
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
8.6 Contents of Authentication Failure Notification
The following describes how to read the contents of the mail shown in Figure 8-5.
5. Time at which the authentication failure occurred. The time is the local time.
6. User name used in the authentication failure.
7. IP address of machine that attempted authentication.
8-9
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 8 XSCF Mail Function
The following describes how to read the contents of mail shown in Figure 8-6.
8-10
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
8.8 Contents of Suspension Mail Notification
8-11
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 8 XSCF Mail Function
8-12
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Chapter 9 XSCF Firmware Upgrade and
Dump
This chapter explains how to upgrade the XSCF firmware, obtain a dump, and record logs.
Contents:
9.1 Upgrading the XSCF Firmware 9-2
9.2 How to Get XSCF Dump Information and Collect Logs 9-4
9-1
All Rights Reserved,Copyright (C) FUJITSU LINITED 2003
Chapter 9 XSCF Firmware Upgrade and Dump
― XSCF firmware
― POST/OBP firmware
― Disk firmware
The basics of firmware upgrading from the machine administration function are provided below.
1. Display the operations guide menu from the Machine Administration Menu.
- Firmware Registration
- Firmware Application
2. Copy the firmware from the CD-ROM, and register it by the machine administration
menu.
4. Using the machine administration menu, verify the result of the firmware update. (When
POST/OBP is included in the updated firmware, the OS must be restarted to check the
applied firmware.)
1. The REMCS agent function can download the firmware data to a work directory. This is
initiated 1) when operator manually requested, or 2) when periodic connection to the
REMCS center is made and new firmware is available. Since these functions are
REMCS agent functions, see the REMCS Agent Operator's Guide for ESF for more
9-2
All Rights Reserved,Copyright (C) FUJITSU LINITED 2003
9.1 Upgrading the XSCF Firmware
information.
1. Display the operations guide menu from the Machine Administration Menu.
2. Copy the firmware from the work directory , and register it by the machine administration
menu.
4. Using the machine administration menu, verify the result of the firmware update. (When
POST/OBP is included in the updaed firmware, the OS must be restarted to check the
applied firmware.)
Note:
A console the XSCF shell and a standard console are disconnected immediately after the update
of the firmware. Please login again when you use the XSCF.
Next: 9.2 How to Get XSCF Dump Information and Collect Logs
9-3
All Rights Reserved,Copyright (C) FUJITSU LINITED 2003
Chapter 9 XSCF Firmware Upgrade and Dump
Getting dump and log information using the Machine Administration Menu
The Machine Administration Menu that operates on the Solaris OE is used to get log
information. For the actual menu screen, see the Machine Administration Guide for ESF.
When the user gets log information, the user can also get XSCF dump information.
The following explains how to get log information using the Machine Administration Menu.
- Log Save
1. Display the log management menu from the Machine Administration Menu.
3. Logs will be collected under /var/opt/FJSVmadm/log. Move the collected log file to any
directory, if needed.
4. Forward collected information to a trained field engineer for more detail analysis.
Note:
Since the name of folder that holds the logs and dump file can be changed without notice, see
the Machine Administration Guide for ESF for more information.
The following table shows the details of collected log information by Machine Administration
Menu. For reference purposes, the table also shows the maximum size of the logs that can be
displayed by the XSCF shell.
9-4
All Rights Reserved,Copyright (C) FUJITSU LINITED 2003
9.2 How to Get XSCF Dump Information and Collect Logs
Note:
The dump file and log files are compressed. Some additional log files, which are logged by
Machine Administration Menu but not listed in the above table, are included to the collected log.
For the trigger for obtaining each log type and the maximum capacity for each log file required
to save the log data, see the Machine Administration Guide for ESF.
9-5
All Rights Reserved,Copyright (C) FUJITSU LINITED 2003
Chapter 9 XSCF Firmware Upgrade and Dump
9-6
All Rights Reserved,Copyright (C) FUJITSU LINITED 2003
Appendix A Warning Messages
This appendix explains the error notification messages that XSCF outputs to the server OS
console (standard console) or outputs by mail or the SNMP function.
Contents:
A.1 Message Types A-2
A.2 Messages in Each Function A-4
A-1
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
A.1 Message Types
When an error occurs in the system, XSCF takes various action against this error, such as,
displays a warning or notification message on the OS console, send TRAP to a SNMP manager,
send a mail report to the administrator, and take a log. This section describes the messages that
are most likely to be seen by the user when a server error or the status of the server is reported.
― System messages
― Error messages
System messages
A system message displays information in simple form when a server error or the status of the
server is reported. You can locate the point of problem by displayed system message on the
console.
The following table lists the system messages and their meaning.
A-2
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
required.
Detected failure on the memory module(DIMM size = xxxxMB) A memory error occurred.
To investigate the details of these system messages, you can use the XSCF Web function and
XSCF shell to view the error information that includes the error messages. For information about
viewing Web pages and using the XSCF commands, see "Chapter5 How to Use the XSCF Web
Function" and "Chapter6 How to Use the XSCF Command Shell".
Error messages
An error message is a detailed message from the server. Purpose of system message is to
report the event briefly, and purpose of error message is to reports detail information of event,
such as, the cause and a part number. Error message is consist of up to 48 characters. You can
see the messages as a part of output from show-error-log command on XSCF shell.
For the list of error messages and corrective actions, see the list of messages displayed by the
show-error-logs command described in "Appendix B XSCF Log Information".
A-3
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
A.2 Messages in Each Function
This section explains how to read typical messages displayed or logged by each of the XSCF
functions.
The following explains typical messages displayed on the standard console (OS console) when
XSCF detects a server error.
Three examples of messages displayed when an error has been detected or the status is being
reported are given below.
Additionally, system messages and other specific detailed messages are displayed.
For information about error codes and error messages, see "Appendix B XSCF Log
Information".
When a server error is detected, the XSCF mail function sends a report to the user. The mail
message includes both the system messages and error messages described in the previous
section.
A-4
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
For an example of an actually displayed mail message, see "Chapter 8 XSCF Mail Function".
When a server error is detected, the XSCF SNMP agent function generates a trap. The SNMP
message contains the error messages.
For an example of an actually displayed mail message, see "Chapter7 XSCF SNMP Agent
Function".
The XSCF Web function has a menu to display logs. When you find any abnormality on XSCF
Web, such as the CHECK LED on the remote panel blinks, you may want to check the log.
By selecting a log on XSCF Web, you can see system message and error message with detail
information.
When the user logs in to XSCF from a terminal that can use the XSCF shell, messages are
displayed on the initial screen. When the CHECK LED on the operator panel and remote panel
blinks or a server error is recognized on the standard console (OS console), the XSCF show-
error-logs command can be used to display system messages and error massages together with
other specific messages.
For display examples and more information about the initial message and XSCF command
messages, see "Chapter6 How to Use the XSCF Command Shell" and "Appendix B XSCF Log
Information".
A-5
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
A-6
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Appendix B XSCF Log Information
Appendix B describes the following XSCF log information, which can be viewed on the XSCF
console using XSCF commands:
Contents:
B.1 XSCF Error Log List and Actions B-2
B.2 XSCF Power Log List B-51
B.3 XSCF Event Logs List B-57
B.4 XSCF Error Code Table B-64
B-1
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2002
B.1 XSCF Error Log List and Actions
This section lists all error log information displayed when the show-error-logs command is
executed on the XSCF console. The table below explains the items in the error log list. For
information about a command to display logs and options to the command, see "Chapter6 How to
Use the XSCF Command Shell". To view logs by error code, use "XSCF Error Code Table" in
Section B.4.
A list of errors for each error level recorded in the error log is provided below.
B-2
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Alarm
The following table lists alarm-level errors (errors that prevent the continuation of system
operation) and the actions to be taken.
To view errors by error code, use "XSCF Error Code Table" in Section B.4.
C0800200
Message: SCF-CPU Illegal Data storage interrupt
Explanation: An illegal interrupt occurred.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0800300
Message: SCF-CPU Illegal Instruction storage interrupt
Explanation: An illegal interrupt occurred.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0800400
Message: SCF-CPU Illegal External interrupt
Explanation: An illegal interrupt occurred.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0800500
Message: SCF-CPU Illegal Alignment interrupt
Explanation: An illegal interrupt occurred.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
B-3
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C0800600
Message: SCF-CPU Illegal Program interrupt
Explanation: An illegal interrupt occurred.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0800700
Message: SCF-CPU Illegal System call interrupt
Explanation: An illegal interrupt occurred.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0800800
Message: SCF-CPU Illegal PIT interrupt
Explanation: An illegal interrupt occurred.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0800900
Message: SCF-CPU Illegal FIT interrupt
Explanation: An illegal interrupt occurred.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0800A00
Message: SCF-CPU Illegal WDT interrupt
Explanation: An illegal interrupt occurred.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0800B00
Message: SCF-CPU Illegal Data TLB miss interrupt
Explanation: An illegal interrupt occurred.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0800C00
Message: SCF-CPU Illegal Instruction TLB miss interrupt
Explanation: An illegal interrupt occurred.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0800D00
Message: SCF-CPU Illegal Debug interrupt
Explanation: An illegal interrupt occurred.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0801000
Message: SYSTEM CONTROL BUS data transfer error
Explanation: A data transfer error was detected on the system control bus.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0801100
Message: SYSTEM CONTROL BUS data transfer timeout error
Explanation: A data transfer timeout was detected on the system control bus.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
B-4
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C0801200
Message: SYSTEM CONTROL BUS data transfer incomplete
Explanation: A data transfer interrupt was detected on the system control bus.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0802000
Message: TOD/NVRAM compare error
Explanation: A compare error was detected in NVRAM (TOD).
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0803000
Message: SCF-SDRAM compare error
Explanation: A compare error was detected in SCF-SDRAM.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0803100
Message: SCF-SDRAM uncorrectable error
Explanation: An ECC UE was detected in SCF-SDRAM.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0803200
Message: SCF-SDRAM correctable error
Explanation: An ECC CE was detected in SCF-SDRAM.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0804000
Message: SCFC parity error
Explanation: A parity error was detected in the SCFC.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0804100
Message: SCFC parity test error
Explanation: A parity detection function error was detected in the SCFC.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0805000 Message: XSCF(current bank) checksum error
Explanation: The checksum for the current bank in SCF-FMEM is defferent from
one, which is stored before swtiching of bank.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0805300
Message: XSCF boot header error
Explanation: A boot header identifier error was detected in SCF-FMEM.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0806000
Message: SCF-CPU PIT timeout error
Explanation: A PIT interrupt did not occur in the SCF-CPU.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
B-5
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C0806100
Message: SCF-CPU WDT timeout error
Explanation: A WDT interrupt did not occur in the SCF-CPU.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0807000
Message: SCF-SDRAM ECC CE test error
Explanation: ECC did not detect a correctable error in SCF-SDRAM.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0807100
Message: SCF-SDRAM ECC CE test compare error
Explanation: ECC corrected a correctable error in SCF-SDRAM, but the
correction was incorrect.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0807200
Message: SCF-SDRAM ECC UE test error
Explanation: ECC did not detect an uncorrectable error in SCF-SDRAM.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0808000
Message: UART loop-back error
Explanation: A data receive timeout was detected.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0808100
Message: UART compare error
Explanation: A transmission data compare error was detected.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C0809200
Message: TOD error
Explanation: A calendar operation error was detected.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C080F000
Message: SCF-CPU reset retry out
Explanation: SCF cannot complete its resetting, properly. or WDT reset failed.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C1000100
Message: System hangup(RESET)
Explanation: A startup monitoring timeout error was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB or CPU. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C1000200
Message: System hangup(OBP)
Explanation: An OBP monitoring timeout error was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB or CPU. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
B-6
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C1001100
Message: System hangup(OS) Level=1
Explanation: An interrupt ACK monitoring error was detected while OS was
working.
Replacement part/number: 01: SB/ 00
Action: Replace the SB or CPU. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C1001200
Message: System hangup(OS) Level=2
Explanation: An interrupt ACK monitoring error was detected while OS was not
working.
Replacement part/number: 01: SB/ 00
Action: Replace the SB or CPU. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C201020n Message: PSU#n failed
Explanation: A power supply error (power supply not redundant) was detected.
Replacement part/number: 41:PSU/0-2
Action: Replace the PSU.
(Or for models 250-R:
Replace the PSU-CAGE.
For models 250-P/450-R/450-Q:
Replace the Power board and IO-back panel.
Or Replace the SB.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C201030n Message: PSU#n PWOK error
Explanation: An output voltage error was detected.
Replacement part/number: 41:PSU/0-2
Action: Replace the PSU.
(Or for models 250-R:
Replace the PSU-CAGE.
For models 250-P/450-R/450-Q:
Replace the Power board and IO-back panel.
Or Replace the SB.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C2010400 Message: PSU mount error
Explanation: An uninstalled PSU (power supply not redundant) was detected.
Replacement part/number: 41:PSU/0-2
Action: Install the missing PSU.
(Or for models 250-R:
Replace the PSU-CAGE.
For models 250-P/450-R/450-Q:
Replace the Power board and IO-back panel.
Or Replace the SB.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C20106FF
Message: PSU configuration error
Explanation: The number of PSUs is incorrect.
Replacement part/number: FF:-/FF
Action: Check the PSU configuration. Contact the system administrator or
a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C20107FF
(Alarm) Message: PSU type is not proper #0-DC,#1-DC,#2-AC
Explanation: The type of PSU is not appropriate.
Replacement part/number: FF:-/FF
Action: Check the PSU configuration. Contact the system administrator or
a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
B-7
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C202010n
Message: DDC-A not mounted
Explanation: The DDC-A is not installed.
Replacement part/number: 43: DDC-A/0
Action: Install the DDC-A. (Or Replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C202020n
Message: CPUDDC not mounted
Explanation: The CPUDDC is not installed.
Replacement part/number: 42: CPUDDC/ 0-3
Action: Replace the CPU. (Or replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C202030n Message: DDC-A#n alarm
Explanation: A DDC-A device error was detected.
Replacement part/number: 43: DDC-A/0
Action: Replace the DDC-A. (Or Replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C202040n Message: DDC-B#n alarm
Explanation: A DDC-B device error was detected.
Replacement part/number: 44: DDC-B/0
Action: Replace the DDC-B. (Or Replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C202050n Message: CPUDDC#n alarm
Explanation: A CPUDDC device error was detected.
Replacement part/number: 42: CPUDDC/ 0-3
Action: Replace the CPU. (Or replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C202060n Message: DDC-B not mounted
Explanation: The DDC-B is not installed.
Replacement part/number: 44: DDC-B/0
Action: Install the DDC-B. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C20301FF Message: CPU not mounted
Explanation: The CPU is not installed.
Replacement part/number: 11: CPU/ FF
Action: Install the CPU. (Or replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C2111000
Message: Pon sequence timeout(sectionXX) .status:YY
Explanation: A power on sequence timeout was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C2111100 Message: Poff sequence timeout(sectionXX)
Explanation: A power off sequence timeout was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C2111200
Message: Reset sequence timeout(sectionXX) .status:YY
Explanation: A reset sequence timeout was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB or CPU. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
B-8
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C2120100
Message: System(POWER ON) Retry out
Explanation: OFF/ON retries exceeded the limit.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C2120200 Message: System(FATAL) Retry out
Explanation: Retries against fatal error exceeds the limit.
Replacement part/number: 01: SB/ 00
Action: Replace the SB or CPU.
Or for model 450-Q:
Replace the PCI-board.
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C2120300 Message: System(RESET) Retry out
Explanation: Retries, caused by timeout of system starting up by reset, exceeds
the limit.
Replacement part/number: 01: SB/ 00
Action: Replace the SB or CPU.
Or for model 450-Q:
Replace the PCI-board.
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C2120400 Message: System(PON SEQUENCE) Retry out
Explanation: Retries, caused by timeout of system starting up by power-on,
exceeds the limit.
Replacement part/number: 01: SB/ 00
Action: Replace the SB or CPU.
Or for model 450-Q:
Replace the PCI-board.
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C2130100 Message: Unknown SB-TYPE(XXXXXXXX)
Explanation: The SB type is not supported.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C2130300
Message: UPA frequency expectant value is out of range
Explanation: UPA clock frequency value is abnorrmal.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C2130400
Message: Pon sequence error(sectionXX) .status:YY
Explanation: A power-on sequence error was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C306000n Message: THERMAL-SENSOR#n(CPU) access error
Explanation: The system control bus detected an access error.
Replacement part/number: 01: SB/ 00
Action: Replace the SB or CPU. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C306020n Message: CPU#n thermal alarm(shutdown) xxC
Explanation: An abnormal temperature was detected on the CPU.
Replacement part/number: 11:CPU/0-3
Action: Replace the CPU. (Or replace the SB.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
B-9
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C306030n Message: CPU#n thermal alarm(epoff) xxC
Explanation: An abnormal temperature was detected on the CPU.
Replacement part/number: 11:CPU/0-3
Action: Replace the CPU. (Or replace the SB.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C30B000n
Message: HARDWARE-MONITOR#n access error
Explanation: The system control bus detected an access error.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
B-10
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C30B120n Message: PSU#n xx.xxV(expect xx.xxV)
Explanation: An abnormal voltage was detected.
Replacement part/number: 41: PSU/0-2
Action: Replace the PSU.
(Or Replace the SB.
Or for models 250-R:
Replace the PSU-CAGE.
For models 250-P/450-R/450-Q:
Replace the Power board and IO-back panel.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C30B140n Message: CPUDDC#n xx.xxV(expect xx.xxV)
Explanation: An abnormal voltage was detected.
Replacement part/number: 42: CPUDDC/ 0-3
Action: Replace the CPU. (Or replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C30C0000
Message: SC access error
Explanation: The system control bus detected an access error.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C30C0100
Message: SC PLL lock error
Explanation: A PLL lock error was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C30D000n
Message: XB#n access error
Explanation: The system control bus detected an access error.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C30D010n
Message: XB#n PLL lock error
Explanation: A PLL lock error was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C30E010n Message: FAN-CONTROLLER#n access error
(Alarm) Explanation: A system control bus access error (bus-configuration not
redundant) was detected.
Replacement part/number: 01:SB/00 (model 250-R),
32:FANJT/0-1 (FAN#0-3 of model 250-P/450-R/450-Q)
03:PCI-BD/00 (FAN#4-7 of model 450-R/450-Q)
Action: For model 250-R: Replace the SB.
For models 250-P or 450-R or 450-Q:
Replace the SB if fan from #0 to #3 is specified.
For model 450-Q:
Replace the PCI board if fan from #4 to #7 is specified.
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C30E030n Message: FAN#n alarm (xxxxrpm)
Explanation: An abnormal fan speed (fan-configuration not redundant) was
detected.
Replacement part/number: 31:FAN/0-7
Action: Replace the fan.
(Or Do the action of the above "FAN-CONTROLLER#n".)
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
B-11
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C30E050n Message: FAN#n not mounted
Explanation: A fan is not installed (fan-configuration not redundant)..
Replacement part/number: 31:FAN/0-7
Action: Install the missing FAN.
(Or Do the action of the above "FAN-CONTROLLER#n".)
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C3160300
Message: SB serial number is 0
Explanation: The SB serial number was all 0s.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
C3160400 Message: PANEL serial number is 0
Explanation: The PANEL serial number was all 0s.
Replacement part/number: 02: PANEL/ 00
Action: Replace the panel.
(Or for models 250-P/450-R/450-Q:
Replace the IO-back panel.
Or replace the SB.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CD000600
Message: Unknown SCF-FMEM ID(ID=xx TYPE=xx)
Explanation: An SCF-FMEM with an unsupported ID/type is installed.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE01000n Message: CPU#n JTAG IR setting error
Explanation: A JIR setting error was detected.
Replacement part/number: 11: CPU/ 0-3
Action: Replace the CPU. (Or replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE02000n Message: CPU#n JTAG compare error
Explanation: A setting data compare error was detected.
Replacement part/number: 11: CPU/ 0-3
Action: Replace the CPU. (Or replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE03000n Message: CPU#n JTAG status error
Explanation: A JTAG status timeout was detected.
Replacement part/number: 11: CPU/ 0-3
Action: Replace the CPU. (Or replace the SB. ) Contact the system
administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE0301FF Message: CPU JTAG status error
Explanation: A JTAG status timeout was detected.
Replacement part/number: 11: CPU/ 0-3
Action: Replace the CPU. (Or replace the SB. ) Contact the system
administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE030200
Message: SC JTAG status error
Explanation: A JTAG status timeout was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE0303FF
Message: XB#0-2 JTAG status error
Explanation: A JTAG status timeout was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
B-12
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
CE0304FF
Message: XB#3-5 JTAG status error
Explanation: A JTAG status timeout was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE03050n Message: U2P#n JTAG status error
Explanation: A JTAG status timeout was detected.
Replacement part/number: 01: SB/ 00
Action: For models 250-R/250-P/450-R:
Replace the SB.
For model 450-Q:
Replace the PCI board if U2P#0's error . (Or replace the SB. )
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE04000n Message: CPU#n JTAG ID code error
Explanation: An ID code error was detected.
Replacement part/number: 11: CPU/ 0-3
Action: Replace the CPU. (Or replace the SB. ) Contact the system
administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE040100
Message: SC JTAG ID code error
Explanation: An ID code error was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE04020n
Message: XB#n JTAG ID code error
Explanation: An ID code error was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE04030n Message: U2P#n JTAG ID code error
Explanation: An ID code error was detected.
Replacement part/number: 01: SB/ 00
Action: For models 250-R/250-P/450-R:
Replace the SB.
For model 450-Q:
Replace the PCI board if U2P#0's error . (Or replace the SB. )
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE07100n Message: Correct. error count over flow(offline desired)
Explanation: The CPU is degraded because too many ECC correctable errors
are detected.
Replacement part/number: 11: CPU/ 0-3
Action: Replace the CPU. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
CE080000
Message: SYSTEM CONTROL BUS fatal timeout(SC Register)
Explanation: SYSTEM CONTROL BUS timeout error was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE09000n
Message: SYSTEM CONTROL BUS fatal timeout(XB#n Register)
Explanation: SYSTEM CONTROL BUS timeout error was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
B-13
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
CE0A0000
Message: SYSTEM CONTROL BUS fatal timeout(SC History)
Explanation: SYSTEM CONTROL BUS timeout error was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE20010n
Message: Processor fatal error(xxxxxxxx)
Explanation: A CPU fatal error occurred.
Replacement part/number: 11: CPU/ 0-3
Action: Replace the CPU. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE20020n
Message: Invalid adrs. error(00000000)
Explanation: A CPU fatal error occurred. The cause may be due to software.
Replacement part/number: 01: SB/ 00 or 11: CPU/ 0-3
Action: Replace the CPU or SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE20040n
Message: Invalid interrupt error(xxxxxxxx)
Explanation: A CPU fatal error occurred. The cause may be due to software.
Replacement part/number: 01: SB/ 00 or 11: CPU/ 0-3
Action: Replace the CPU or SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE200700
Message: DTAG error(xxxxxxxx)
Explanation: A fatal error occurred.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE200900
Message: Cache coherent error(xxxxxxxx)
Explanation: A fatal error occurred.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE201000 Message: UPA I/O fatal error IO#0(xxxxxxxx)
Explanation: A fatal error occurred.
Replacement part/number: 01: SB/ 00
Action: For models 250-R/250-P/450-R:
Replace the SB.
For model 450-Q:
Replace the PCI board. (Or replace the SB. )
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE201200
Message: UPA I/O fatal error IO#2(xxxxxxxx)
Explanation: A fatal error occurred.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE201300
Message: UPA I/O fatal error IO#3(xxxxxxxx)
Explanation: A fatal error occurred.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
B-14
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
CE20150n Message: Interconnect data error(xxxxxxxx)
Explanation: A fatal error occurred.
Replacement part/number: 11: CPU/ 0-3 or 01: SB/ 00
Action: For the Replacement part is CPU:
Replace the CPU. (Or Replace the SB.)
For the Replacement part is SB:
Replace the SB.
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE209400 Message: Fatal error(SC)
Explanation: Logging errors when a fatal error occurs.
Replacement part/number: FF:-/FF
Action: Please check the errors occurred before or after. Then perform it as
follow. Replace the SB or CPU. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE209500 Message: Fatal error(XB)
Explanation: Logging errors when a fatal error occurs.
Replacement part/number: FF:-/FF
Action: Please check the errors occurred before or after. Then perform it as
follow. Replace the SB or CPU. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE209600 Message: Fatal error(CPU#n,mm)
Explanation: Logging errors when a fatal error occurs. (mm is detail code.)
Replacement part/number: FF:-/FF
Action: Please check the errors occurred before or after. Then perform it as
follow. Replace the SB or CPU. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE209700 Message: RC data error(yy)(xxxxxxxx)
Explanation: RC data errors caused a fatal error.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. However, if the error occurred after a failure to
upgrade firmware, retry the upgrade. If the upgrade still fails, replace the SB. Contact the
system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE209800
Message: Hardware too many errors(xxxxxxxx)
Explanation: Analysis is not possible because there are too many error factors.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE209900
Message: Hardware no error region(xxxxxxxx)
Explanation: Analysis is not possible because there are no error factors.
Replacement part/number: 01: SB/ 00
Action: Replace the SB or CPU. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE20F10n Message: Fatal error(Internal)(xxxxxxxx)
Explanation: A fatal error occurred.
Replacement part/number: 11: CPU/0-3 or 01: SB/00
Action: For the Replacement part is CPU:
Replace the CPU. (Or Replace the SB.)
For the Replacement part is SB:
Replace the SB.
Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
CE20F200
Message: Fatal error(Outside)(xxxxxxxx)
Explanation: A fatal error occurred.
Replacement part/number: 01: SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
B-15
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
CE20FB00
Message: Bus protocol error(xxxxxxxx)
Explanation: A fatal error occurred.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Alarm/:3/:XSCF
B-16
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
10100030 Message: DTAG Init error(DTAG)
Explanation: At the initialization of DTAG, an error was detected.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:POST
B-17
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
170000FF Message: [BEBUS]Probing Basic ebus device failed
Explanation: Initialization of the OBP failed.
[BEBUS=Required ebus node phase]
Replacement part/number: FF: -/FF or 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
180000FF Message: [OBPENV]initialization failed
Explanation: Initialization of the OBP failed.
[OBPENV=About EEPROM phase]
Replacement part/number: FF: -/FF or 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
181000FF Message: [OBPENV]eeprom data invalid(set-default)
Explanation: Abnormality is detected in the panel EEPROM, where environment
variables of OBP are stored. [OBPENV=About EEPROM phase]
Replacement part/number: FF: -/FF or 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
182000FF Message: [OBPENV]eeprom data invalid
Explanation: Abnormality is detected in the panel EEPROM, where system ID
information is stored. [OBPENV=About EEPROM phase]
Replacement part/number: FF: -/FF or 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
190000FF Message: [EEBUS]Probing Extended ebus device failed
Explanation: Initialization of the OBP failed.
[EEBUS=Ebus node phase]
Replacement part/number: FF: -/FF or 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
1A0000FF Message: [CPU]Probing CPU failed
Explanation: Initialization of the OBP failed.
[CPU=CPU node phase]
Replacement part/number: FF: -/FF or 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
1B0000FF Message: [NVRAMRC]initialization failed
Explanation: Initialization of the OBP failed.
[NVRAMRC=NVRAMRC execution phase]
Replacement part/number: FF: -/FF
Action: Please confirm the description of nvramrc. Then contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
1C00002n Message: [PCI]Probing PCI failed(PCI#0n)
Explanation: Trouble occurred while probing the PCI slot.
[PCI=PCI probing phase]
Replacement part/number: 92: PCI/ 00-08
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
1D00004n Message: [SCSI]Probing PCI failed(SCSI#n)
Explanation: Trouble occurred while probing the SCSI.
[SCSI=SCSI probing phase]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
1E0000XX Message: [NET]Probing PCI failed(LAN#n)
(XX=42,43) Explanation: Trouble occurred while probing the LAN.
[NET=NET probing phase]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
1F000044 Message: [ATAPI]Probing PCI failed(ATAPI)
Explanation: Trouble occurred while probing the IDE.
[ATAPI=IDE probing phase]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
B-18
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
230000FF Message: [CONS]install console failed
Explanation: Trouble occurred in the console install processing.
[CONS=Console setting phase]
Replacement part/number: 01: SB/ 00
Action: Please confirm values of the OBP environment variable, boot-
device. Then contact a FE. When you find any message in prior to this message, check the
earlier message, first.
Error level/report level/error detection source: Alarm/:0/:OBP
240000FF Message: [SBinf]SBinf failed
Explanation: SB configration information notification failed.
[SBinf=Startup phase]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
250000FF Message: [BOOTP]Boot Process failed
Explanation: Boot process failed. [BOOTP=Boot phase1]
Replacement part/number: FF: -/ FF
Action: Please confirm values of the OBP environment variable,boot-
device. Then contact a FE. Please follows that when another one is ahead of this message.
Error level/report level/error detection source: Alarm/:0/:OBP
251000XX Message: [BOOTP]disk label error
(*p) Explanation: A disk label error was detected. [BOOTP=Boot phase1]
Replacement part/number: 01: SB/ 00 or 92: PCI/ 00-08 or 91: DISK/ 0-5
Action: Please confirm whether Disk specified by OBP environment
variable (or boot-device) is boot possible Disk( or CDROM). Then contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
252000XX Message: [BOOTP]SCSI error
(*p) Explanation: A disk boot error was detected. [BOOTP=Boot phase1]
Replacement part/number: 01: SB/ 00 or 92: PCI/ 00-08 or 91: DISK/ 0-5
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
253000XX Message: [BOOTP]SCSI I/O error
(*p) Explanation: A disk boot error was detected. [BOOTP=Boot phase1]
Replacement part/number: 01: SB/ 00 or 92: PCI/ 00-08 or 91: DISK/ 0-5
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
254000XX Message: [BOOTP]PCI S-ERR
(XX=50-55) Explanation: A PCI address parity error occurred. [BOOTP=Boot phase1]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
255000XX Message: [BOOTP]network error(LAN#n)
(XX=42,43) Explanation: A network boot error occurred. [BOOTP=Boot phase1]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
256000XX Message: [BOOTP]network error(LAN#n)
(XX=42,43) Explanation: A network boot error occurred. [BOOTP=Boot phase1]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
25700044 Message: [BOOTP]IDE error
Explanation: A CDROM/DVD boot error occurred. [BOOTP=Boot phase1]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
260000FF Message: [BOOTB]Boot block error
Explanation: Execution of the boot block was abnormally terminated.
[BOOTB=Boot block phase]
Replacement part/number: FF: -/ FF
Action: It might not be a correct disk. Please confirm the disk.
Error level/report level/error detection source: Alarm/:0/:OBP
B-19
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
261000XX Message: [BOOTB]disk label error
(*p) Explanation: A disk label error was detected. [BOOTB=Boot block phase]
Replacement part/number: 01: SB/ 00 or 92: PCI/ 00-08 or 91: DISK/ 0-5
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
262000XX Message: [BOOTB]SCSI error
(*p) Explanation: A disk boot error was detected. [BOOTB=Boot block phase]
Replacement part/number: 01: SB/ 00 or 92: PCI/ 00-08 or 91: DISK/ 0-5
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
263000XX Message: [BOOTB]SCSI I/O error
(*p) Explanation: A disk boot error was detected. [BOOTB=Boot block phase]
Replacement part/number: 01: SB/ 00 or 92: PCI/ 00-08 or 91: DISK/ 0-5
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
264000XX Message: [BOOTB]PCI S-ERR
(XX=50-55) Explanation: A PCI address parity error occurred.
[BOOTB=Boot block phase]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
265000XX Message: [BOOTB]network error(LAN#n)
(XX=42,43) Explanation: A network boot error occurred. [BOOTB=Boot block phase]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
266000XX Message: [BOOTB]network error(LAN#n)
(XX=42,43) Explanation: A network boot error occurred. [BOOTB=Boot block phase]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
270000FF Message: [BOOTOS]Boot OS failed
Explanation: Initialization of OS on the OBP environment was abnormally
terminated. [BOOTOS=OS phase]
Replacement part/number: FF: -/ FF
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
271000XX Message: [BOOTOS]disk label error
(*p) Explanation: A disk label error was detected. [BOOTOS=OS phase]
Replacement part/number: 01: SB/ 00 or 92: PCI/ 00-08 or 91: DISK/ 0-5
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
272000XX Message: [BOOTOS]SCSI error
(*p) Explanation: A disk boot error was detected. [BOOTOS=OS phase]
Replacement part/number: 01: SB/ 00 or 92: PCI/ 00-08 or 91: DISK/ 0-5
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
273000XX Message: [BOOTOS]SCSI I/O error
(*p) Explanation: A disk boot error was detected. [BOOTOS=OS phase]
Replacement part/number: 01: SB/ 00 or 92: PCI/ 00-08 or 91: DISK/ 0-5
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
274000XX Message: [BOOTOS]PCI S-ERR
(XX=50-55) Explanation: A PCI address parity error occurred.
[BOOTOS=OS phase]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
B-20
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
275000XX Message: [BOOTOS]network error(LAN#n)
(XX=42,43) Explanation: A network boot error occurred. [BOOTOS=OS phase]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
276000XX Message: [BOOTOS]network error(LAN#n)
(XX=42,43) Explanation: A network boot error occurred. [BOOTOS=OS phase]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
280000FF Message: [OSRUN]OS Running OBP failed
Explanation: An OBP call was not completed whille OS runninng.
[OSRUN=OS running phase]
Replacement part/number: FF: -/ FF
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
281000FF Message: [OSRUN]OS Running OS abort
Explanation: Control is moved to OBP because OS gave up managing any
serious trouble. [OSRUN=OS running phase]
Replacement part/number: FF: -/ FF
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
2A0000FF Message: [POFF]Power off sequence failed
Explanation: Power off sequence failed. [POFF=Power off phase]
Replacement part/number: FF: -/ FF
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
2B0000FF Message: [REBOOT]Reboot sequence failed
Explanation: Reset sequence failed. [REBOOT=Reboot phase]
Replacement part/number: FF: -/ FF
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
2C0000FF Message: [INIT0]Init 0 sequence failed
Explanation: Problem is detected during shutting down to OBP.
[INIT0=Init 0 phase]
Replacement part/number: FF: -/ FF
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:0/:OBP
2E0000FF Message: [RED]RED State exception occurred
Explanation: A RED state occurred.
[RED=RED/WDR/XIR phase]
Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
2E1000FF Message: [RED]Watchdog reset occurred
Explanation: A watchdog reset occurred. [RED=RED/WDR/XIR phase]
Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
2E2000FF Message: [RED]Reset Switch
Explanation: A Reset Switch was pressed.
[RED=RED/WDR/XIR phase]
Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
xx080ayy Message: [ppp]Instruction Access Error
(*p) Explanation: An illegal trap error occurred.
Replacement part/number: 01: SB/ 00 or 11: CPU/ 0-3 or 21: SLOT/ 00-15
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
B-21
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
xx0810yy Message: [ppp]Illegal instruction
(*p) Explanation: An illegal trap error occurred.
Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
xx0832yy Message: [ppp]Data Access Error
(*p) Explanation: An illegal trap error occurred.
Replacement part/number: 01: SB/ 00 or 11: CPU/ 0-3 or 21: SLOT/ 00-15
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
xx0864yy Message: [ppp]Fast Instruction Access MMU Miss
(*p) Explanation: An illegal trap error occurred.
Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
xx0868yy Message: [ppp]Fast Data Access MMU Miss
(*p) Explanation: An illegal trap error occurred.
Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Alarm/:3/:OBP
(*p) xx:Test phase number,yy:Component number,zzz:Component name,
ppp:Phase abbreviation. Please refer to Table B-1-12 and Table B-1-13 for details.
Information
The content of the error messages might be changed because of the function improvement.
B-22
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Warning
The following table lists warning-level errors (e.g., errors in which operation can continue but in
a degraded state) and the actions to be taken.
To view errors by error code, use “XSCF Error Code Table" in Section B.4.
B-23
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
80809300
Message: NVRAM battery low
Explanation: Low battery voltage was detected.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
B-24
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
8306010n Message: CPU#n thermal high warning
Explanation: High CPU temperature was detected.
Replacement part/number: 11: CPU/ 0-3
Action: Replace the CPU. (Or replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
83080100 Message: SB-FRU data error
Explanation: An FRU data error on the SB was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
830B010n Message: PSU#n xx.xxV(expect xx.xxV)
Explanation: An abnormal voltage was detected.
Replacement part/number: 41: PSU/0-2
Action: Replace the PSU.
(Or Replace the SB.
Or for models 250-R:
Replace the PSU-CAGE.
For models 250-P/450-R/450-Q:
Replace the Power board and IO-back panel.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
830B0500
Message: DDC-B xx.xxV(expect xx.xxV)
Explanation: An abnormal voltage was detected.
Replacement part/number: 44: DDC-B/0
Action: Replace the DDC-B. (Or replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
830B090n
Message: DDC-A xx.xxV(expect xx.xxV)
Explanation: An abnormal voltage was detected.
Replacement part/number: 43: DDC-A/ 0
Action: Replace the DDC-A. (Or replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
830B0B00
Message: DDC-C#n xx.xxV(expect xx.xxV)
Explanation: An abnormal voltage was detected.
Replacement part/number: 01: SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
830B0D0n Message: PSU#n xx.xxV(expect xx.xxV)
Explanation: An abnormal voltage was detected.
Replacement part/number: 41: PSU/0-2
Action: Replace the PSU.
(Or Replace the SB.
Or for models 250-R:
Replace the PSU-CAGE.
For models 250-P/450-R/450-Q:
Replace the Power board and IO-back panel.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
830B0F0n Message: PSU#n xx.xxV(expect xx.xxV)
Explanation: An abnormal voltage was detected.
Replacement part/number: 41: PSU/0-2
Action: Replace the PSU.
(Or Replace the SB.
Or for models 250-R:
Replace the PSU-CAGE.
For models 250-P/450-R/450-Q:
Replace the Power board and IO-back panel.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
B-25
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
830B110n Message: PSU#n xx.xxV(expect xx.xxV)
Explanation: An abnormal voltage error was detected.
Replacement part/number: 41: PSU/0-2
Action: Replace the PSU.
(Or Replace the SB.
Or for models 250-R:
Replace the PSU-CAGE.
For models 250-P/450-R/450-Q:
Replace the Power board and IO-back panel.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
830B130n Message: CPUDDC#n xx.xxV(expect xx.xxV)
Explanation: An abnormal voltage was detected.
Replacement part/number: 42: CPUDDC/ 0-3
Action: Replace the CPU. (Or replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
830E000n Message: FAN-CONTROLLER#n access warning
Explanation: A system control bus access error (bus-configuration remains
redundant) was detected.
Replacement part/number: 01:SB/00 (model 250-R),
32:FANJT/0-1 (FAN#0-3 of model 250-P/450-R/450-Q)
03:PCI-BD/00 (FAN#4-7 of model 450-R/450-Q)
Action: For model 250-R: Replace the SB.
For models 250-P or 450-R or 450-Q:
Replace the SB if fan from #0 to #3 is specified.
For model 450-Q:
Replace the PCI board if fan from #4 to #7 is specified.
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
8310010n
Message: CPU#n-FRU data error
Explanation: An FRU data error on CPU#n was detected.
Replacement part/number: 11: CPU/ 0-3
Action: Replace the CPU. (Or Replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
8310020n Message: Unknown CPU#n FRU-IDCODE xx, so using xx
Explanation: Unknown CPU ID code was detected.
Replacement part/number: 11: CPU/ 0-3
Action: Replace the CPU. (Or Replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
8311010n Message: SLOT#n-FRU data error
Explanation: An FRU data error in SLOT#n was detected.
Replacement part/number: 21: SLOT/ 00-15
Action: Replace the SLOT(memory). (Or Replace the SB.) Contact the
system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
83120100 Message: PCI-BD-FRU data error
Explanation: An FRU data error on the PCI-BD was detected.
Replacement part/number: 03: PCI-BD/ 00 (model 450-Q only)
Action: Replace the PCI board (model 450-Q only).
(Or Replace the SB.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
B-26
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
8313010n Message: PSU#n-FRU data error
Explanation: An FRU data error on PSU#n was detected.
Replacement part/number: 41: PSU/ 0-2
Action: Replace the PSU.
(Or for models 250-R:
Replace the PSU-CAGE.
For models 250-P/450-R/450-Q:
Replace the Power board and IO-back panel.
Or Replace the SB.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
8314010n Message: SCSI-BP#n-FRU data error
Explanation: An FRU data error on SCSI-BP#n was detected.
Replacement part/number: 04: SCSI-BP/ 0-1
Action: Replace the SCSI-BP.
(Or for models 250-P/450-R/450-Q:
Replace the IO-back panel.
Or Replace the SB.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
84yyyy01
(*x) Message: FAN#xx alarm (XXXXXXXX,CODE=XXXXXXXX)
Explanation: A decrease in fan speed was detected.
Replacement part/number: A1:-/FF
Action: Replace the fan of the specified IO device. Contact the system
administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
84yyyy02
(*x) Message: Power Unit alarm (XXXXXXXX,CODE=XXXXXXXX)
Explanation: A power supply error was detected.
Replacement part/number: A1:-/FF
Action: Replace the power supply unit of the specified IO device.
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
84yyyy03
(*x) Message: Memory backup battery warning (XXXXXXXX,XX)
Explanation: A memory battery error was detected.
Replacement part/number: A1:-/FF
Action: Replace the battery of the specified IO device. Contact the system
administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
84yyyy04
(*x) Message: Extend power warning (XXXXXXXX,CODE=XXXXXXXX)
Explanation: An extended power interface error was detected.
Replacement part/number: A1:-/FF
Action: Check the power interface connected to the specified IO device.
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
84yyyy05
(*x) Message: UPS alarm (XXXXXXXX,CODE=XXXXXXXXX)
Explanation: A UPS error was detected.
Replacement part/number: A1:-/FF
Action: Check the UPS unit connected to the specified IO device. Contact
the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
84yyyy06
(*x) Message: Thermal alarm (XXXXXXXX,CODE=XXXXXXXX)
Explanation: A temperature error was detected.
Replacement part/number: A1:-/FF
Action: Improve the environment. Contact the system administrator or a
FE.
Error level/report level/error detection source: Warning/:3/:XSCF
B-27
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
84yyyy07
(*x) Message: AC alarm (XXXXXXXX,CODE=XXXXXXXXX)
Explanation: Abnormality is detected about the power supplied to the system.
Replacement part/number: A1:-/FF
Action: Check the voltage of power supplied to the system. Contact the
system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
84yyyyF2
(*x) Message: RCI Status check timeout(XXXXXXXX code=YY)
Explanation: An RCI network communication timeout error was detected.
Replacement part/number: A1:-/FF
Action: Check the RCI cable connection, power supply of the connected
device, and the connection for RCI termination. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
84yyyyF3
(*x) Message: RCI neuron interface error code = XXXX
Explanation: A RCI control circuits token error was detected.
Replacement part/number: A1:-/FF
Action: Check the RCI cable connection, power supply of the connected
device, and the connection for RCI termination. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
84yyyyF4
(*x) Message: Unknown RCI device was detected(XXXXXXXX)
Explanation: An unregistered RCI device was detected.
Replacement part/number: A1:-/FF
Action: After checking the unregistered device, reconstruct the RCI if
installation of the device is required. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
870005FF
Message: SCF-LAN IP duplicate
Explanation: An IP address duplication error was detected.
Replacement part/number: FF:-/FF
Action: Check the LAN environment. Contact the system administrator or a
FE.
Error level/report level/error detection source: Warning/:3/:XSCF
8D000500
Message: SCF-FMEM bank change error
Explanation: Bank switching was disabled.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
B-28
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
8E07200n Message: Correct. error count over flow
Explanation: Count of ECC correctable errors detected by the CPU#n exceeds
the threshold.
Replacement part/number: FF: -/ FF
Action: Please check the errors occurred before. Then perform it as follow.
Replace the SLOT(memory). (Or Replace the SB.) Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
8E07300n
Message: CPU#n JTAG-IDCODE xx differ from FRU-IDCODE yy
Explanation: A CPU ID CODE error was detected.
Replacement part/number: 11: CPU/ 0-3
Action: Replace the CPU. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
B-29
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
8E20FA00
Message: Watchdog timeout(xxxxxxxx)
Explanation: A watchdog timeout was detected.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
8E20FB0n
Message: Bus protocol error(xxxxxxxx)
Explanation: A fatal error occurred.
Replacement part/number: 11: CPU/ 0-3
Action: Replace the CPU or SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C0800E00
Message: SCF-CPU WATCHDOG reset
Explanation: A watchdog reset was detected.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3 /:XSCF
C1002100
Message: SCFC access error (addr=xxxxxxxx)
Explanation: An SCFC access error was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C20107FF
(Warning) Message: PSU type is not proper #0-DC,#1-DC,#2-AC
Explanation: The type of PSU is not appropriate.
Replacement part/number: FF:-/FF
Action: Check the PSU configuration. Contact the system administrator or
a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C2040200 Message: UPS alarm
Explanation: A battery error (BPS) was detected.
Replacement part/number: 81: UPS/ 00
Action: Replace the UPS. (Or Replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C3010000 Message: THERMAL-SENSOR(Panel) access error
Explanation: The system control bus detected an access error.
Replacement part/number: 02: PANEL/ 00
Action: Replace the panel.
(For models 250-P/450-R/450-Q:
Replace the IO-back panel.
Or Replace the SB.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C3020000 Message: PANEL-EEPROM access error
Explanation: The system control bus detected an access error.
Replacement part/number: 02: PANEL/ 00
Action: Replace the panel.
(For models 250-P/450-R/450-Q:
Replace the IO-back panel.
Or Replace the SB.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C3030000 Message: PANEL-SWITCH-CONTROLLER access error
Explanation: The system control bus detected an access error.
Replacement part/number: 02:PANEL/00
Action: Replace the panel.
(For models 250-P/450-R/450-Q:
Replace the IO-back panel.
Or Replace the SB.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
B-30
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C3040000
Message: LED-CONTROLLER#0 access error
Explanation: The system control bus detected an access error.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C3050000 Message: LED-CONTROLLER#1 access error
Explanation: The system control bus detected an access error.
Replacement part/number: 02:PANEL/00
Action: Replace the panel.
(For models 250-P/450-R/450-Q:
Replace the IO-back panel.
Or Replace the SB.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C307000n Message: CPUDDC-VID#n access error
Explanation: The system control bus detected an access error.
Replacement part/number: 11:CPU/0-3
Action: Replace the CPU. (Or Replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C3080000
Message: SB-FRU access error
Explanation: The system control bus detected an access error.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C309000n
Message: DDC-VID#n access error
Explanation: The system control bus detected an access error.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C30A000n
Message: DUAL FMEM CONTROLLER#n access error
Explanation: The system control bus detected an access error.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C30E010n Message: FAN-CONTROLLER#n access error
(Warning) Explanation: Lost of fan redundancy, caused by access error to system control
bus, is detected. And, fans are changed to mode of higher rotation speed.
Replacement part/number: 01:SB/00 (model 250-R),
32:FANJT/0-1 (FAN#0-3 of model 250-P/450-R/450-Q)
03:PCI-BD/00 (FAN#4-7 of model 450-R/450-Q)
Action: For model 250-R: Replace the SB.
For models 250-P or 450-R or 450-Q:
Replace the SB if fan from #0 to #3 is specified.
For model 450-Q:
Replace the PCI board if fan from #4 to #7 is specified.
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C30E020n Message: FAN#n alarm (xxxrpm)
Explanation: An abnormal fan speed (fan-configuration remains redundant) was
detected.
Replacement part/number: 31: FAN/ 0-7
Action: Replace the fan.
(Or Do the action of the above "FAN-CONTROLLER#n".)
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
B-31
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C30E040n Message: FAN#n not mounted
Explanation: A fan was not installed (fan-configuration remains redundant).
Replacement part/number: 31:FAN/0-7
Action: Install the missing FAN.
(Or Do the action of the above "FAN-CONTROLLER#n".)
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C30F0000 Message: PCI-MOUNT-SENSOR#0 access error
Explanation: The system control bus detected an access error.
Replacement part/number: 01: SB/ 00
Action: For models 250-P/450-R/450-Q:
Replace the SB.
For model 250-R,
Repalce the PCI-RISER.
(Or Replace the SB.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C310000n
Message: CPU#n-FRU access error
Explanation: An FRU access error on CPU#n was detected.
Replacement part/number: 11: CPU/ 0-3
Action: Replace the CPU. (Or Replace the SB.) Contact the system
administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C311000n Message: SLOT#n-FRU access error
Explanation: An FRU access error in SLOT#n was detected.
Replacement part/number: 21: SLOT/ 00-15
Action: Replace the SLOT(memory). (Or Replace the SB.) Contact the
system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C3120000 Message: PCI-BD-FRU access error
Explanation: An FRU access error on the PCI-BD was detected.
Replacement part/number: 03: PCI-BD/ 00 (model 450-Q only)
Action: Replace the PCI board (model 450-Q only).
(Or Replace the SB.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C313000n Message: PSU#n-FRU access error
Explanation: An FRU access error on PSU#n was detected.
Replacement part/number: 41: PSU/ 0-2
Action: Replace the PSU.
(Or for models 250-R:
Replace the PSU-CAGE.
For models 250-P/450-R/450-Q:
Replace the Power board and IO-back panel.
Or Replace the SB.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C314000n Message: SCSI-BP#n-FRU access error
Explanation: An FRU access error on SCSI-BP#n was detected.
Replacement part/number: 04: SCSI-BP/ 0-1
Action: Replace the SCSI-BP.
(Or for models 250-P/450-R/450-Q:
Replace the IO-back panel.
Or Replace the SB.)
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C4yyyy1n
(*x) Message: FAN#xx alarm (XXXXXXXX,CODE=XXXXXXXX)
Explanation: A fan error was detected.
Replacement part/number: A1:-/FF
Action: Replace the fan of the specified IO device. Contact the system
administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
B-32
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C4yyyy2n
(*x) Message: Power Unit alarm (XXXXXXXX,CODE=XXXXXXXX)
Explanation: A power supply error was detected.
Replacement part/number: A1:-/FF
Action: Replace the power supply unit of the specified IO device. Contact
the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C4yyyy3n Message: Memory backup battery alarm (XXXXXXXX,XX)
(*x) Explanation: A memory battery error was detected.
Replacement part/number: A1:-/FF
Action: Replace the battery of the specified IO device. Contact the system
administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C4yyyy4n
Message: Extend power alarm (XXXXXXXX,CODE=XXXXXXXX)
(*x)
Explanation: An extended power interface error report was detected.
Replacement part/number: A1:-/FF
Action: Check the power interface connected to the specified IO device.
Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C4yyyy5n Message: UPS alarm (XXXXXXXX,CODE=XXXXXXXXX)
(*x) Explanation: A UPS error was detected.
Replacement part/number: A1:-/FF
Action: Check the UPS unit connected to the specified IO device. Contact
the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C4yyyy6n
(*x) Message: Thermal alarm (XXXXXXXX,CODE=XXXXXXXX)
Explanation: An abnormal temperature was detected.
Replacement part/number: A1:-/FF
Action: Improve the environment. Contact the system administrator or a
FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C4yyyy7n
(*x) Message: AC alarm (XXXXXXXX,CODE=XXXXXXXXX)
Explanation: Abnormality of power is detected.
Replacement part/number: A1:-/FF
Action: Check the voltage of power supplied to the system. Contact the
system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C4yyyy8n Message: Diag alarm (XXXXXXXX,CODE=XXXXXXXX)
(*x) Explanation: A device specific error was detected.
Replacement part/number: A1:-/FF
Action: Replace the specified IO device. Contact the system administrator
or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C4yyyy9n Message: Mount alarm (XXXXXXXX,CODE=XXXXXXXX)
(*x) Explanation: A mount error was detected.
Replacement part/number: A1:-/FF
Action: Check the installation status of the specified IO device. Contact the
system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C7000100 Message: SCF-LAN memory access error
Explanation: A memory access error was detected.
Replacement part/number: 01:SB/00
Action: Check the LAN environment. Then replace the SB. Contact the
system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
B-33
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C7000200
Message: SCF-LAN loop-back connection error
Explanation: A data compare error was detected.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C7000300
Message: SCF-LAN MAC duplicate
Explanation: A MAC address duplication error was detected.
Replacement part/number: 01:SB/00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
C7000400 Message: SCF-LAN framing error
Explanation: A framing error was detected.
Replacement part/number: 01:SB/00
Action: Check the LAN environment. replace the SB. Contact the system
administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
CD000100
Message: SCF-FMEM write protect error
Explanation: A write-protection error was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
CD000200
Message: SCF-FMEM update error(erase)
Explanation: An erase failure was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
CD000300
Message: SCF-FMEM update error(write)
Explanation: A write failure was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
CD000400
Message: SCF-FMEM update error(checksum)
Explanation: A checksum error after a write was detected.
Replacement part/number: 01: SB/ 00
Action: Replace the SB. Contact the system administrator or a FE.
Error level/report level/error detection source: Warning/:3/:XSCF
DF000100
Message: SCF system-down (XXXXXXXX)
Explanation: A XSCF system error occurred.
Replacement part/number: 01: SB/ 00
Action: Needs a dump of XSCF. And replace the SB. Contact the system
administrator or a FE.
Error level/report level/error detection source: Warning/:3 /:XSCF
DF001000
Message: SCF-CPU illegal interrupt
Explanation: A XSCF CPU illegal interrupt occurred.
Replacement part/number: 01: SB/ 00
Action: Needs a dump of XSCF. And replace the SB. Contact the system
administrator or a FE.
Error level/report level/error detection source: Warning/:3 /:XSCF
B-34
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Table B-1-6 Warning-level errors[2]
B-35
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
0712000n Message: FATAL check2 error(CPU#n)
Explanation: Master Class0 overflowed.
Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
0713000n Message: FATAL check2 error(CPU#n)
Explanation: Master Class1 overflowed.
Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
080000XX Message: Timer1 increment error(U2P(Timer)#n)
Explanation: A U2P timer error was detected.
[(n,XX)=(0,08),(1,09),(2,0a),(3,0b)]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
0900000n Message: Tick/Stick error(CPU#n)
Explanation: A Tick error was detected.
Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
0910000n Message: Tick/Stick error(CPU#n)
Explanation: A Stick error was detected.
Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
1120006n Message: Probing memory error(SLOT#n)
Explanation: A SPD checksum error was detected.
Replacement part/number: 21: SLOT/ 00-15
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
1121006n Message: Probing memory error(SLOT#n)
Explanation: A SPD data error was detected.
Replacement part/number: 21: SLOT/ 00-15
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
112300F0 Message: Probing memory error(No avail memory)
Explanation: There is no memory which can be used.
Replacement part/number: FF: -/ FF
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
120z00XX Message: Memory Address Line error(SLOT#yy,yy)
[z=0,1,2] Explanation: A memory error occurred.
[(yy,yy , XX)=(00,01 , 80),(02,03 , 81)..(14,15 , 87)]
Replacement part/number: 22: SLOT/ 00-15
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
140z000n Message: Softint register error(CPU#n)
[z=0,1..4] Explanation: A CPU softint register error was detected.
Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
141z000n Message: Tick register error(CPU#n)
[z=0,1..3] Explanation: A CPU Tick register error was detected.
Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
B-36
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
142z000n Message: Stick register error(CPU#n)
[z=0,1..3] Explanation: A CPU STick register error was detected.
Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
151000XX Message: U2P Registers error(U2P#n)
Explanation: A U2P register error was detected.
[(n,XX)=(0,08),(1,09),(2,0a),(3,0b)]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
151100XX Message: U2P Registers error(U2P#n)
Explanation: A U2P register error was detected.
[(n,XX)=(0,08),(1,09),(2,0a),(3,0b)]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
152z00XX Message: U2P Interrupt error(yyyyy)
[z=0,1..3] Explanation: Expected interrupt is not detected.
The definition of yyyy and code XX are as follows:
― U2P#0-3[XX=08-0B]
― U2P(Timer)#0-3[XX=10-13]
― PCI#0-8[XX=20-28]
― TTY-A[XX=33]、TTY-B[XX=34]
― HPC#0-2[XX=35-37]
― SCSI#0-1[XX=40-41]
― LAN#0-1[XX=42-43]
― ATAPI#0[XX=44]
― USBC[XX=45]
Replacement part/number: 01: SB/ 00 or IO
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
153z00XX Message: U2P Timer/Counter error(U2P(Timer)#n)
[z=0,1..9] Explanation: A U2P timer error was detected.
[(n,XX)=(0,08),(1,09),(2,0a),(3,0b)]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
154z00XX Message: U2P Functional error(U2P#n)
[z=0,1..3] Explanation: A U2P functional error was detected.
[(n,XX)=(0,08),(1,09),(2,0a),(3,0b)]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
1560002n Message: U2P PCI Slot error(PCI#0n)
Explanation: Abnormal reponse is received from a PCI slot.
Replacement part/number: 92: PCI/ 00-08
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
16000039 Message: TOD test error(TOD)
Explanation: Calendar clock is not operational.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
16100033 Message: TTY test error(TTY-A)
Explanation: A TTY register error was detected.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
B-37
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
162000XX Message: HPC3130 error(HPC#n)
Explanation: A HotPlug functional error was detected.
[(XX,n)=(35,0),(36,1),(37,2)]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
170v0042 Message: Ethernet register error(LAN#0)
[v=0,1,2] Explanation: A LAN register error was detected.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
171v0042 Message: Ethernet inernal loopback error(LAN#0)
[v=0,1..7] Explanation: A LAN loopback error was detected.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
172v0042 Message: Ethernet Physical Layer loopback(10Mbps) error(LAN#0)
[v=0,1..7] Explanation: A LAN loopback error was detected.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
173v0042 Message: Ethernet PHY loopback(100Mbps) error(LAN#0)
[v=0,1..7] Explanation: A LAN loopback error was detected.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
1740004n Message: Ultra320 Registers error(SCSI#n)
Explanation: A SCSI register error was detected. [n=0,1]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
17500043 Message: GIGA-Ether Registers error(LAN#1)
Explanation: A LAN register error was detected.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
17600044 Message: IDE Registers error(IDE)
Explanation: A IDE register error was detected.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
17700045 Message: USB error(USBC)
Explanation: A USB error was detected.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
17710045 Message: USB error(USBC)
Explanation: A USB error was detected.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
8xx008yy Message: instruction_access_exception(CPU#n)
9xx008yy Explanation: An instruction access exception was detected.
(*p) Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
B-38
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
8xx00Ayy Message: instruction_access_error(zzz)
9xx00Ayy Explanation: An instruction access error was detected.
(*p) Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
8xx030yy Message: data_access_exception(CPU#n)
9xx030yy Explanation: A data access exception was detected.
(*p) Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
8xx032yy Message: data_access_error(zzz)
9xx032yy Explanation: A UE of cache or memory was detected.
(*p) Replacement part/number: 11: CPU/ 0-3 or 21: SLOT/ 00-15 or 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
8xx034yy Message: mem_address_not_aligned(CPU#n)
9xx034yy Explanation: A data alignment error was detected.
(*p) Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
8xx04Wyy Message: interrupt_level_W(CPU#n)
9xx04Wyy Explanation: An illegal interruption was detected.
(*p) Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
8xx060yy Message: interrupt_vector(zzz)
9xx060yy Explanation: An illegal interruption was detected.
(*p) Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
8xx063yy Message: ECC_error(zzz)
9xx063yy Explanation: A UE of cache and memory was detected.
(*p) Replacement part/number: 11: CPU/ 0-3 or 21: SLOT/ 00-15
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
8xx064yy Message: fast_instruction_access_mmu_miss(CPU#n)
9xx064yy Explanation: An instruction access mmu miss was detected.
(*p) Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
8xx068yy Message: fast_data_access_mmu_miss(CPU#n)
9xx068yy Explanation: A data access mmu miss was detected.
(*p) Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
8xx06Cyy Message: fast_data_access_protection(CPU#n)
9xx06Cyy Explanation: A data protection exception was detected.
(*p) Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
8xxTTTyy Message: (Trap name(CPU#n))
9xxTTTyy Explanation: Any other trap, which is not described above, is detected.
(*p) Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
B-39
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
921032XX Message: data_access_error(SLOT#yy,yy)
Explanation: A memory error occurred.
[(yy,yy , XX)=(00,01 , 80),(02,03 , 81)..(14,15 , 87)]
Replacement part/number: 22: SLOT/ 00-15
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
921063XX Message: ECC_error(SLOT#yy,yy)
Explanation: A memory error occurred.
[(yy,yy , XX)=(00,01 , 80),(02,03 , 81)..(14,15 , 87)]
Replacement part/number: 22: SLOT/ 00-15
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
xx0C000n Message: CPU Degrade error(CPU#n)
(*p) Explanation: Part of internal sections in CPU is degraded.
Replacement part/number: 11: CPU/ 0-3
Action: Contact a FE.
Error level/report level/error detection source: Warning/:3/:POST
(*p) xx:Test phase number,yy:Component number,zzz:Component name,
ppp:Phase abbreviation. Please refer to Table B-1-12 and Table B-1-13 for details.
B-40
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
A0600044 Message: ATAPI was degraded
Explanation: An ATAPI of the dergadation by OS occurred.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:0/:OBP
A07000XX Message: LAN#n was degraded
[XX=42,43] Explanation: An LAN of the dergadation by OS occurred.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:0/:OBP
A0900033 Message: ttya was degraded
Explanation: A tty-a of the dergadation by OS occurred.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:0/:OBP
A0A00034 Message: ttyb was degraded
Explanation: A tty-b of the dergadation by OS occurred.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:0/:OBP
B0000039 Message: TOD was degraded
Explanation: A TOD of the dergadation by OS occurred.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:0/:OBP
B0200032 Message: SCFI was degraded
Explanation: A SCFI of the dergadation by OS occurred.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:0/:OBP
B030003d Message: SCFI(panel) was degraded
Explanation: A SCFI(panel) of the dergadation by OS occurred.
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:0/:OBP
B04000XX Message: HPC was degraded(HPC#n)
Explanation: A HPC of the dergadation by OS occurred.
[(n,XX)=(0,35),(1,36),(2,37),(3,38)]
Replacement part/number: 01: SB/ 00
Action: Contact a FE.
Error level/report level/error detection source: Warning/:0/:OBP
B-41
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
(*M): About part number, refer to Table B-1-14 for details.
Information
The content of the error messages might be changed because of the function improvement.
B-42
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Notice
The following table lists notice-level errors (e.g., errors in which system operation can continue)
and the actions to be taken.
To view errors by error code, use “XSCF Error Code Table" in Section B.4.
B-43
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
42040100 Message: AC Power Down
Explanation: A power outage (ACOFF) occurred.
Replacement part/number: FF:-/FF
Action: Check the installation environment. Contact the system
administrator or a FE.
Error level/report level/error detection source: Notice/:3/:XSCF
42048100
Message: AC Power Recovered
Explanation: Power was restored (ACON).
Replacement part/number: FF:-/FF
Action: Contact the system administrator or a FE.
Error level/report level/error detection source: Notice/:3/:XSCF
430102FF Message: FAN speed low CAUSE: temperature lower
Explanation: Because the inlet temperature has decreased and returned to the
normal range, fan speed has decreased.
Replacement part/number: FF:-/FF
Action: None.
Error level/report level/error detection source: Notice/:0/:XSCF
430103FF Message: FAN speed high CAUSE: temperature higher
Explanation: Because the inlet temperature was above the normal range, fan
speed increased.
Replacement part/number: FF:-/FF
Action: Check the environment.
Error level/report level/error detection source: Notice/:0/:XSCF
430E060n
Message: FAN#n mounted
Explanation: A FAN has been mounted.
Replacement part/number: 31: FAN/ 0-7
Action: None.
Error level/report level/error detection source: Notice/:0/:XSCF
431501FF Message: OBP-FMEM version changed
Explanation: OBP-FMEM was upgraded to a new version.
Replacement part/number: FF:-/FF
Action: Check the version.
Error level/report level/error detection source: Notice/:3/:XSCF
431601FF Message: SB changed
Explanation: An SB has been replaced.
Replacement part/number: FF:-/FF
Action: None.
Error level/report level/error detection source: Notice/:3/:XSCF
431602FF
Message: PANEL changed
Explanation: A panel has been replaced.
Replacement part/number: FF:-/FF
Action: None.
Error level/report level/error detection source: Notice/:3/:XSCF
431605FF
Message: SB or PANEL changed
Explanation: A SB or a panel has been replaced.
Replacement part/number: FF:-/FF
Action: Contact a FE.
Error level/report level/error detection source: Notice/:3/:XSCF
431606FF
Message: Restore error from SCF-FMEM to PANEL-EEPROM
Explanation: The restoration from FMEM to PANEL failed.
Replacement part/number: FF:-/FF
Action: Contact the system administrator or a FE.
Error level/report level/error detection source: Notice/:3/:XSCF
431607FF
Message: Backup error from PANEL-EEPROM to SCF-FMEM
Explanation: The backup from PANEL to FMEM failed.
Replacement part/number: FF:-/FF
Action: Contact the system administrator or a FE.
Error level/report level/error detection source: Notice/:3/:XSCF
B-44
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
44yyyyA0
(*x) Message: Status changed (XXXXXXXX,CODE=XXXXXXXX)
Explanation: An RCI IO device is recovered or re-mounted.
Replacement part/number: A1:-/FF
Action: None.
Error level/report level/error detection source: Notice/:0/:XSCF
44yyyyE0
(*x) Message: Emergency Power-off (XXXXXXXX)
Explanation: An RCI IO device was forcibly powered off.
Replacement part/number: A1:-/FF
Action: Contact the system administrator or a FE.
Error level/report level/error detection source: Notice/:3/:XSCF
46110000
Message: This is a TEST log
Explanation: A test(Notice level) is executed in XSCF shell function.
Replacement part/number: FE:test/FF
Action: None.
Error level/report level/error detection source: Notice/:3/:XSCF
4D000700
Message: FMEM data error,PANEL-EEPROM cannot be restored
Explanation: PANEL cannot be restored because FMEM data error.
Replacement part/number: A1:-/FF
Action: Contact the system administrator or a FE.
Error level/report level/error detection source: Notice/:3/:XSCF
4E200800
Message: DTAG correctable error(xxxxxxxx)
Explanation: A DTAG error was corrected by the hardware.
Replacement part/number: 01:SB/00
Action: None.
Error level/report level/error detection source: Notice/:0/:XSCF
4E20F00n
Message: Processor detected error(xxxxxxxx)
Explanation: A CPU detected error.
Replacement part/number: 11: CPU/ 0-3
Action: Please follow the message of OS or POST/OBP.
Error level/report level/error detection source: Notice/: 0/:XSCF
4E20F50n
Message: Correct. error(Internal)(xxxxxxxx)
Explanation: An error happened inside of CPU was corrected by the hardware.
Replacement part/number: 11:CPU/0-3
Action: Contact the system administrator or a FE.
Error level/report level/error detection source: Notice/: 0/:XSCF
4E20F600
Message: Correct. error(Outside)(xxxxxxxx)
Explanation: An error external to the CPU was corrected by the hardware.
Replacement part/number: 01:SB/00
Action: Contact the system administrator or a FE.
Error level/report level/error detection source: Notice/: 0/:XSCF
500001FF
Message: SNMP Agent already started
Explanation: The SNMP agent function has already started.
Replacement part/number: FF:-/FF
Action: None.
Error level/report level/error detection source: Notice/:0/:XSCF
500002FF
Message: SNMP Agent already stopped
Explanation: The SNMP agent function has already stopped.
Replacement part/number: FF:-/FF
Action: None.
Error level/report level/error detection source: Notice/:0/:XSCF
B-45
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
500003FF Message: SNMP Agent couldn't start by bad configuration
Explanation: Inadequate settings were detected when the SNMP agent function
started.
Replacement part/number: FF:-/FF
Action: Recheck the settings.
Error level/report level/error detection source: Notice/:0/:XSCF
500004FF
Message: SNMP Agent failed to send trap
Explanation: The SNMP agent function failed to issue a trap.
Replacement part/number: FF:-/FF
Action: Needs a dump of XSCF. Contact the system administrator or a FE.
Error level/report level/error detection source: Notice/:0/:XSCF
500110FF
to Message: SNMP Agent stopped by firmware
500170FF Explanation: The SNMP agent function stopped for a reason related to firmware.
Replacement part/number: FF:-/FF
Action: Needs a dump of XSCF. Contact the system administrator or a FE.
Error level/report level/error detection source: Notice/:0/:XSCF
501001FF
Message: Illegal XSCF host name specified
Explanation: An illegal host name of XSCF was specified.
Replacement part/number: FF:-/FF
Action: Recheck the specified host name of XSCF.
Error level/report level/error detection source: Notice/:0/:XSCF
501002FF
Message: Communication to SMTP server timeout
Explanation: A timeout occurred during communication with the SMTP server.
Replacement part/number: FF:-/FF
Action: Recheck the server setting.
Error level/report level/error detection source: Notice/:0/:XSCF
501003FF
Message: Communication failure to SMTP server occurred
Explanation: A communication error with the SMTP server occurred.
Replacement part/number: FF:-/FF
Action: Recheck the server setting.
Error level/report level/error detection source: Notice/:0/:XSCF
501004FF
Message: Mail report function is not enabled
Explanation: The mail report function has not been enabled.
Replacement part/number: FF:-/FF
Action: Recheck the mail report function settings.
Error level/report level/error detection source: Notice/:0/:XSCF
501010FF
Message: Mail access mode is not enabled
Explanation: Mail access mode has not been enabled.
Replacement part/number: FF:-/FF
Action: Recheck the mail access mode settings.
Error level/report level/error detection source: Notice/:0/:XSCF
501011FF
Message: Illegal SMTP server address specified
Explanation: An illegal SMTP server address was specified.
Replacement part/number: FF:-/FF
Action: Recheck the mail access mode settings.
Error level/report level/error detection source: Notice/:0/:XSCF
501012FF
Message: No SMTP server specified
Explanation: A SMTP server has not been specified.
Replacement part/number: FF:-/FF
Action: Specify a SMTP server.
Error level/report level/error detection source: Notice/:0/:XSCF
B-46
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
501013FF
Message: Illegal SMTP server or mail address specified
Explanation: An illegal SMTP server or mail address was specified.
Replacement part/number: FF:-/FF
Action: Recheck the SMTP server or mail address.
Error level/report level/error detection source: Notice/:0/:XSCF
501020FF
Message: Mail access mode already disable
Explanation: Mail access mode has been disabled.
Replacement part/number: FF:-/FF
Action: None.
Error level/report level/error detection source: Notice/:0/:XSCF
81110000 Message: This is a TEST log
Explanation: A test(Warning level) is executed in Machine Administration
function.
Replacement part/number: FE:test/FF
Action: None.
Error level/report level/error detection source: Notice/:3/:XSCF
86110000 Message: This is a TEST log
Explanation: A test(Warning level) is executed in XSCF shell function.
Replacement part/number: FE:test/FF
Action: None.
Error level/report level/error detection source: Notice/:3/:XSCF
C1110000
Message: This is a TEST log
Explanation: A test(Alarm level) is executed in Machine Administration function.
Replacement part/number: FE:test/FF
Action: None.
Error level/report level/error detection source: Notice/:3/:XSCF
C6110000
Message: This is a TEST log
Explanation: A test(Alarm level) is executed in XSCF shell function.
Replacement part/number: FE:test/FF
Action: None.
Error level/report level/error detection source: Notice/:3/:XSCF
B-47
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Table B-1-11 Notice-level errors[3]
Information
The content of the error messages might be changed because of the function improvement.
B-48
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Table B-1-12 POST/OBP test phase number
Number: Phase abbreviation: Number: Phase abbreviation: Number: Phase abbreviation:
Explanation: Explanation: Explanation:
11: RST: Rreset phase 1B: NVRAMRC: NVRAMRC 28: OSRUN: OS running phase
execution phase
12: BI1: Inialization-1 1C: PCI: PCI probing phase 2A: POFF: Power off phase
phase
13: BI2: Initialization-2 1D: SCSI: SCSI probing phase 2B: REBOOT: Reboot phase
phase
14: L1: Initialization-3 1E: NET: NET probing phase 2C: INIT0: Init 0 phase
phase
15: U2P: U2P node phase 1F: ATAPI: IDE probing phase 2E: RED: RED/WDR/XIR
phase
16: CTIMER: Timer node phase 23: CONS: Console setting 32: WARNING: WARNING
phase phase
17: BEBUS: Required ebus 24: SBINF: Startupphase 33: AutoBootStop:
node phase AutoBootStop phase
18: OBPENV: About EEPROM 25: BOOTP: Boot phase1 A0: Degraded phase by OS
phase
19: EEBUS: Ebus node phase 26: BOOTB: Boot block phase
1A: CPU: CPU node phase 27: BOOTOS: OS phase
B-49
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
44 DDC-B(DDC21) 0
81 UPS 0
82 (SDU) * Used by ESF -
83 (BATTERY) * Used by ESF -
91 DISK 0~5
92 PCI slot 00~08
93 (TAPE) * Used by ESF -
a1 RCI FF(hex)
FD U2P *Not replacement part 0,2,3
FE Error log for test FF(hex)
FF Cannot specified. FF(hex)
- IO-BP 0
- POWER-BD 0
- PSU-CAGE 0
* : The pair of replacement SLOT number are (00,01), (02,03), .. (14,15)
B-50
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
B.2 XSCF Power Log List
This section lists all power log information displayed when the show-power-logs command is
executed on the XSCF console. The following table explains the items in the power log list. For
information about a command to display power log and options to the command, see "Chapter6
How to Use the XSCF Command Shell".
Type Type of power log and unique code for the type
The hardware source that generated the power event and the unique
Source
code
B-51
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Source: 01:NVRAM/TOD
Detailed code: x81000000
Explanation: Power-on was executed by the NVRAM/TOD timer setting.
An XSCF requests power-on of external facility.
Source: 01:NVRAM/TOD
Detailed code: x82000000
Explanation: Power-on was executed by the NVRAM/TOD timer setting.
A delayed startup of the system was performed.
Source: 02:RCI-IO
Detailed code: xXX000000
Explanation: Power-on was executed by the RCI-IO.
XX indicates the node number of RCI-IO instruction source.
Source: 02:RCI-IO
Detailed code: x81000000
Explanation: Power-on was executed by the RCI-IO.
An XSCF requests power-on of external facility..
Source: 02:RCI-IO
Detailed code: x82000000
Explanation: Power-on was executed by the RCI-IO.
A delayed startup of the system was performed.
Source: 03:SYSTEM-CONSOLE (*pl)
Detailed code: x00000000
Explanation: Power-on was executed from the system console.
Source: 0C:UPS
Detailed code: x01000000
Explanation: Power was turned on because of recovery from power failure.
The power restoration is informed via the UPC.
Source: 0C:UPS
Detailed code: x84000000
Explanation: Power on sequence, caused by recovery from power failure, was
proceeding. A delayed startup of the system was performed.
Source: 10:RCI-synchronize
Detailed code: xXX000000
Explanation: Power-on was requested to other RCI node.
XX indicates the node number, which is requested the power-on by this
system.
Source: 11:LAN
Detailed code: x00000000
Explanation: Power-on was executed via the LAN.
Source: 11:LAN
Detailed code: x81000000
Explanation: Power-on was executed via the LAN.
An XSCF requests power-on of external facility.
Source: 11:LAN
Detailed code: x82000000
Explanation: Power-on was executed via the LAN.
A delayed startup of the system was performed.
Source: 12:TTY
Detailed code: x00000000
Explanation: Power-on was executed via TTY.
Source: 12:TTY
Detailed code: x81000000
Explanation: Power-on was executed via TTY.
An XSCF requests power-on of external facility.
Source: 12:TTY
Detailed code: x82000000
Explanation: Power-on was executed via TTY.
A delayed startup of the system was performed.
Source: 13:PC
Detailed code: x00000000
Explanation: Power-on was executed by the PC interface.
Source: 13:PC
Detailed code: x81000000
Explanation: Power-on was executed by the PC interface.
An XSCF requests power-on of external facility.
B-52
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Source: 13:PC
Detailed code: x82000000
Explanation: Power-on was executed by the PC interface.
A delayed startup of the system was performed.
Source: 17:RCI-Host
Detailed code: xXX000000
Explanation: Power-on was requested by the RCI-Host.
XX indicates the node number of RCI-Host, which request power-on to this
system.
Source: 17:RCI-Host
Detailed code: x81000000
Explanation: Power-on was executed by the RCI-Host.
An XSCF requests power-on of external facility.
Source: 17:RCI-Host
Detailed code: x82000000
Explanation: Power-on was executed by the RCI-Host.
A delayed startup of the system was performed.
Source: 18:HTTP
Detailed code: x00000000
Explanation: Power-on was executed via HTTP.
Source: 18:HTTP
Detailed code: x81000000
Explanation: Power-on was executed via HTTP.
An XSCF requests power-on of external facility.
Source: 18:HTTP
Detailed code: x82000000
Explanation: Power-on was executed via HTTP.
A delayed startup of the system was performed.
Source: 80:Retry
Detailed code: x01000000
Explanation: A power-off or a power-on retry was made.
The retry is caused by FATAL.
Source: 80:Retry
Detailed code: x02000000
Explanation: A power-off or a power-on retry was made.
The retry is caused by an alive-check error.
Source: 80:Retry
Detailed code: x03000000
Explanation: A power-off or a power-on retry was retried.
The retry is caused by a SPARC instruction.
Source: 80:Retry
Detailed code: x04000000
Explanation: A power-off or a power-on retry was retried.
The retry is caused by a SCF sequence error.
Source: 80:Retry
Detailed code: x05000000
Explanation: A power-off or a power-on retry was retried.
The retry is caused by a firmware update.
30:XIR Source: 00:PANEL-SWITCH
Detailed code: x00000000
Explanation: A reset, type of reset is XIR, was requested from operator panel.
Source: 03:SYSTEM-CONSOLE (*pl)
Detailed code: x00000000
Explanation: A reset, type is XIR, was requested from system console.
Source: 05:CPU
Detailed code: x00000000
Explanation: A reset, type of reset is XIR, was requested from CPU.
Source: 11:LAN
Detailed code: x00000000
Explanation: A reset, type of reset is XIR, was requested via LAN.
Source: 12:TTY
Detailed code: x00000000
Explanation: A reset, type of reset is XIR, was requested via TTY.
Source: 18:HTTP
Detailed code: x00000000
Explanation: A reset, type of reset is XIR, was requested via HTTP.
B-53
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
38:POR Source: 00:PANEL-SWITCH
Detailed code: x00000000
Explanation: A reset, type of reset is POR, was requested from operator panel.
Source: 02:RCI-IO
Detailed code: xXX000000
Explanation: A reset, type of reset is POR, was requested from RCI-IO.
XX indicates the node number of RCI-IO, which request reset to this
system.
Source: 03:SYSTEM-CONSOLE (*pl)
Detailed code: x00000000
Explanation: A reset, type of reset is POR, was requested from system console.
Source: 05:CPU
Detailed code: x00000000
Explanation: A reset, type of reset is POR, was requested from CPU.
Source: 08:FATAL
Detailed code: x00000000
Explanation: A reset, type of reset is POR, was requested due to detection of FATAL.
Source: 0b:ACK-timeout
Detailed code: x00000000
Explanation: A reset, type of reset is POR, was requested due to timeout of
communication (ACK timeout).
Source: 11:LAN
Detailed code: x00000000
Explanation: A reset, type of reset is POR, was requested via LAN.
Source: 12:TTY
Detailed code: x00000000
Explanation: A reset, type of reset is POR, was requested via TTY.
Source: 17:RCI-Host
Detailed code: xXX000000
Explanation: A reset, type of reset is POR, was requested from RCI-HOST.
XX indicates the node number of RCI-HOST, which request reset to this
system.
Source: 18:HTTP
Detailed code: x00000000
Explanation: A reset, type of reset is POR, was requested via HTTP.
Source: 80:Retry
Detailed code: x01000000
Explanation: A reset, type of reset is POR, was requested due to retry against FATAL
problem.
Source: 80:Retry
Detailed code: x02000000
Explanation: A reset, type of reset is POR, was requested due to failure of alive-check.
Source: 81:SCF-Self
Detailed code: x00000000
Explanation: A reset, type of reset is POR,.was requested via SCF.
3f:Reset- Source: ff:Nothing
Release Detailed code: x00000000
Explanation: The reset state was released.
40:Shutdown Source: 00:PANEL-SWITCH
(NML) Detailed code: x00000000
Normal Explanation: A shutdown was requested from operator panel.
system Source: 01:NVRAM/TOD
Detailed code: x00000000
Explanation: A shutdown was requested due to NVRAM/TOD timer setting.
Source: 02:RCI-IO
Detailed code: xXX000000
Explanation: A shutdown was requested from RCI-IO.
XX indicates the node number of RCI-IO, which request shutdown to
this system.
Source: 03:SYSTEM-CONSOLE (*pl)
Detailed code: x00000000
Explanation: A shutdown was requested from system console.
B-54
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Source: 10:RCI-synchronize
Detailed code: xXX000000
Explanation: A shutdown was requested to other RCI node.
XX indicates the node number, which is requested the shutdown by this
system.
Source: 11:LAN
Detailed code: x00000000
Explanation: A shutdown was requested via LAN.
Source: 12:TTY
Detailed code: x00000000
Explanation: A shutdown was requested via TTY.
Source: 17:RCI-Host
Detailed code: xXX000000
Explanation: A shutdown was requested from RCI-HOST.
XX indicates the node number of RCI-HOST, which request shutdown to
this system.
Source: 18:HTTP
Detailed code: x00000000
Explanation: A shutdown was requested via HTTP.
41:Shutdown Source: 0C:UPS
(ALM) Detailed code: x01000000
Abnormal Explanation: A shutdown was requested because of power failure.
system The shutdown is informed via UPC.
Source: 0C:UPS
Detailed code: x02000000
Explanation: A shutdown was requested because of power failure.
The shutdown is informed via SPARC.
Source: 14:Power supply monitoring
Detailed code: x01000000
Explanation: A shutdown was requested because of PSU error.
Source: 14:Power supply monitoring
Detailed code: x06000000
Explanation: A shutdown was requested because of sensor error.
Source: 15:FAN monitoring
Detailed code: x01000000
Explanation: A shutdown was requested because of fan error.
Source: 16:Temperature monitoring
Detailed code: x01000000
Explanation: A shutdown was requested because of CPU temperature error.
Source: 16:Temperature monitoring
Detailed code: x06000000
Explanation: A shutdown was requested because of sensor error.
42:Power-off Source: 00:PANEL-SWITCH
Detailed code: x00000000
Explanation: Power-off was executed with the switch on the operating panel.
Source: 01:NVRAM/TOD
Detailed code: x00000000
Explanation: Power-off was executed by the NVRAM/TOD timer setting.
Source: 02:RCI-IO
Detailed code: xXX000000
Explanation: Power-off was executed from RCI-IO.
XX indicates the node number of RCI-IO, which request the power-off to
this system.
Source: 03:SYSTEM-CONSOLE (*pl)
Detailed code: x00000000
Explanation: Power-off was executed from the system console.
Source: 05:CPU
Detailed code: x00000000
Explanation: Power-off was executed by CPU.
Source: 0b:ACK-timeout
Detailed code: x00000000
Explanation: Power-off was executed due to timeout of communication (ACK timeout).
Source: 0C:UPS
Detailed code: x00000000
Explanation: Power-off was executed because the battery voltage was low.
It was caused by a power outage.
B-55
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Source: 0C:UPS
Detailed code: x01000000
Explanation: Power-off was executed because of the battery error.
Source: 11:LAN
Detailed code: x00000000
Explanation: Power-off was executed via LAN.
Source: 12:TTY
Detailed code: x00000000
Explanation: Power-off was executed via TTY.
Source: 14:Power supply monitoring
Detailed code: x01000000
Explanation: Power-off was executed because of PSU error.
Source: 14:Power supply monitoring
Detailed code: x02000000
Explanation: Power-off was executed because of DDC-A error.
Source: 14:Power supply monitoring
Detailed code: x03000000
Explanation: Power-off was executed because of DDC-B error.
Source: 14:Power supply monitoring
Detailed code: x04000000
Explanation: Power-off was executed because of CPUDDC error.
Source: 14:Power supply monitoring
Detailed code: x05000000
Explanation: Power-off was executed because of DDC-C error.
Source: 16:Temperature monitoring
Detailed code: x01000000
Explanation: Power-off was executed because of CPU temperature error.
Source: 17:RCI-Host
Detailed code: xXX000000
Explanation: Power-off was executed from RCI-HOST.
XX indicates the node number of RCI-HOST, which request the power-off
to this system.
Source: 18:HTTP
Detailed code: x00000000
Explanation: Power-off was executed via HTTP.
Source: 81:SCF-Self
Detailed code: x00000000
Explanation: Power-off was executed due to during the PON/reset sequence.
The power-off is informed via SCF.
50:ACFAIL Source: ff:Nothing
Detailed code: x00000000
Explanation: ACFAIL occurred.
(*pl): In PRIMEPOWER250/450, there are no logs from the system console.
Information
The content of the power logs might be changed because of the function improvement.
B-56
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
B.3 XSCF Event Logs List
This section lists all event log information displayed when the show-event-logs command is
executed on the XSCF console. The following table explains the items in event log list. For
information about a command to display event log and options to the command, see "Chapter6
How to Use the XSCF Command Shell".
Source Type of event causing an entry in the event log and the type code
Detailed code and
Explains the meaning of a detailed code occurring in the event log.
explanation
The event log items displayed by the XSCF are given below.
B-57
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
02:Power Detailed code: xVVnnyy00
[: Power supply Explanation: A power supply error occurred. VV indicates the detailed event, nn
error] indicates the voltage type, and yy indicates the power supply unit number.
(*el) The definition of VV is as follows:
― x01 : A low voltage warning occurred.
― x02 : A low voltage alarm occurred.
― x03 : An overvoltage warning occurred.
― x04 : An overvoltage alarm occurred.
― x05 : A power supply error occurred.
― x11 : A voltage recoverd normally.
The definition of nn is as follows:
― x01 : An abnormal voltage1(:PSU)
― x02 : An abnormal voltage2(:PSU)
― x03 : An abnormal voltage3(:PSU)
― x04 : An abnormal voltage4(:DDC-B)
― x05 : An abnormal voltage5(:DDC-A)
― x06 : An abnormal voltage6(:DDC-C)
― x07 : An abnormal voltage7(:CPUDDC)
― x08 : An abnormal voltage8(:PSU)
The definition of yy is as follows:
― x1m : PSU, m is PSU number from 0 to 2.
― x2m : CPUDDC, m is CPUDDC number from 0 to 3.
― x30 : DDC-A
― x40 : DDC-B
― x50 : DDC-C
When VV is "x05, A power supply error occurred", yy is x1m and m is PSU number from 0
to 2. The definitions of nn are as follows:
― x80 : Not mounted.
― x40 : Alarm level error.
― x20 : Warning level error.
03:NVRAM Detailed code: x02000000
[: Battery error] Explanation: A low voltage error occurred.
(*el)
04:EXTInfo Detailed code: xVVpppp00
[: External Explanation: An external power supply interface error (RCI device only) occurred.
power supply VV indicates the detailed event and pppp indicates the unit-dependent
interface error information.
(RCI device The definition of VV is as follows:
only)] ― x01 : An error occurred at the interface with the EDPC.
(*el) ― x02 : An error occurred at the interface with the EPC.
05:UPS Detailed code: xVVnn0000
[: UPS error] Explanation: A UPS error occurred. VV indicates the detailed event and nn indicates
(*el) the UPS number.
The definition of VV is as follows:
― x01 : The UPS battery voltage is low.
― x02 : A UPS alarm occurred.
06:Thermal Detailed code: xVVqq0000
[: Temperature Explanation: A temperature error occurred. VV indicates the detailed event and qq
error] indicates the sensor ID.
(*el) The definition of VV is as follows:
― x02 : A high ambient temperature warning occurred.
― x04 : A low ambient temperature warning occurred.
― x06 : A high CPU temperature warning occurred.
― x07 : A high CPU temperature alarm occurred.
― x12 : Recovery from he high ambient temperature warning or low ambient
temperature warning was successful.
― x16 : Recovery from the CPU temperature warning was successful.
― x20 : Fan speed increased.
― x21 : Fan speed decreased.
07:PDOWN Detailed code: xVVqq0000
[: Power Explanation: A power outage occurred or power was restored. VV indicates the detailed
outage/power event and qq indicates the detailed information on the source.
recovery] The definition of VV is as follows:
(*el) ― x01 : A power outage occurred.
― x02 : Power was restored.
B-58
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
08:Nodeself Detailed code: x00VVppss
[: Node self- Explanation: A node-specific error occurred. VV indicates the detailed event, pp
error] indicates the first item of detailed information, and ss indicates the second item of
(*el) detailed information.
The definition of VV is as follows:
― x90 : A status check timeout occurred.
― x91 : The IO node address was duplicated.
― x93 : An unregistered node is found.
― x95 : The sensor failed.
When VV is "x95, The sensor failed", ss is sensor number. The definitions of pp are as
follows:
― x01 : The system control bus switcher
― x02 : SB thermal sensor
― x03 : FAN sensor, ss is x00.
― x04 : Inlet sensor
― x05 : CPU thermal sensor
09:Mount Detailed code: x01mmqq00
[: Mount error Explanation: The number of parts was more than the expected value for the installation
(RCI device conditions. mm indicates the part name number and qq indicates the device-dependent
only)] information.
The definition of mm is as follows:
― x01 : Power supply unit
― x02 : Fan
― x03 : Temperature sensor
― x04 : Battery for memory backup
― x05 : UPS
― x06 : Humidity sensor
Detailed code: x02mmqq00
Explanation: The number of parts was less than the expected value for the installation
conditions. mm indicates the part name number and qq indicates the device-dependent
information. The definition of mm is the same as described above.
Detailed code: x03mmqq00
Explanation: The mounting location of the part is different from the correct position. mm
indicates the part name number and qq indicates the device-dependent information.
The definition of mm is the same as described above.
0a:Change Detailed code: xVV000000
[: Status Explanation: A status transition event for the device occurred.
transition event The definition of VV is as follows:
(RCI device ― x01 : The status of the power supply unit changed.
only)] ― x02 : The status of the fan changed.
― x03 : The status of the temperature sensor changed.
― x04 : The status of the battery for memory backup changed.
― x05 : The status of the UPS changed.
― x06 : The status of the humidity sensor changed.
― x07 : The status of the HDD changed.
60:SysInfo Detailed code: xVV000000
[: System Explanation: The system status was reported.
status report] The definition of VV is as follows:
― x00 : Power-off
― x01 : Panic happened.
― x02 : Startup after a shutdown
― x08 : Initialization phase
― x09 : Boot processing
― x0a : The system is in the running state.
61:Panic Detailed code: x00000000
[: Panic Explanation: Panic happened.
report]
B-59
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
62:Config Detailed code: x01mmqqss yyyyyyyy yyyyyyyy yyyyyyyy yyyyyyyy
[: Unit Explanation: A part was added. mm indicates the part name number, qq the part
configuration number, ss the old unit status, y’s the the serial number after replacement without FAN or
change] PSU.
The definition of mm is as follows:
― x02 : Fan
― x03 : PSU
― x05 : Panel
― x06 : SB
― x10 : CPU
― x11 : Slot
― x12 : PCI-BD
― x13 : SCSI-BD
The definition of ss is as follows: (The ss is zero when mm is FAN or PSU.)
The ss the old unit status : 0 7
― bit 0 : valid bit
― bit 1 : Mount information
― bits 2-3 : Reserved
― bit 4 : Alarm level
― bit5 : Warning level
― bit6 : Notice level / Standby level
― bit7 : Sensor abnormal
Detailed code: x02mmqqss yyyyyyyy yyyyyyyy yyyyyyyy yyyyyyyy
Explanation: The part was removed. The definitions from mm to ss are the same as
described above. y’s the the serial number before replacement without FAN or PSU.
71:DevState Detailed code: xqqqqqqqq
[: Unit status Explanation: The status of the unit was displayed. qqqqqqqq indicates the unit-
display] dependent command parameter.
C0:Console Detailed code: xVVpp0000
[: Console Explanation: A console event occurred. VV indicates the detailed event. pp indicates
event] the switching source.
The definition of VV is as follows:
― x01 : The console was switched from the TTY-A console to the SCF-LAN
console.
― x02 : The console was switched from the SCF-LAN console to the TTY-A
console.
The definition of pp is as follows:
― x00 : The console was switched by Machine Administration Menu.
― x01 : The console was switched by SCF Shell.
C1:Access Detailed code: xVVmm0000 xxxxxxxx yyyyyyyy yyyyyyyy
[: SCF access Explanation: An SCF access event occurred. VV indicates the access type, mm the
event] login/logout status, xxxxxxxx the IP address of the access source, and yy.... the account
name.
The definition of VV is as follows:
― x10 : Access to SCF by telnet RW.
― x12 : Access to the telnet shell.
― x20 : Access to the SSL.
― x21 : Access to the HTTP.
― x40 : Access to the serial port.
The definition of mm is as follows:
― x01 : Logged in to the SCF.
― x02 : Logged out from SCF.
― x03 : SCF forcibly disconnect user session due to inactivity timeout.
C2:Author Detailed code: xVV000000 xxxxxxxx yyyyyyyy yyyyyyyy
[: Authentica- Explanation: An authentication failure event occurred when SCF was accessed. VV
tion failure indicates the access type, xxxxxxxx the IP address of the access source, and yy.... the
event] account name that failed last.
The definition of VV is as follows:
― x10 : Access to SCF by telnet RW.
― x12 : Access to the telnet shell.
― x20 : Access to the SSL.
― x21 : Access to the HTTP.
― x40 : Access to the serial port.
B-60
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C3:CPUReq. Detailed code: xVV000000 nnyyyyyy nnyyyyyy nnyyyyyy
[: SPARC Explanation: A request was sent from XSCF to SPARC . VV indicates the detailed
request] event.
The definition of VV is as follows:
― x01 : Request to SPARC for shutdown. nn indicates the event code. yy...
indicates the Detailed code byte 0-2. Detailed code byte 8-F are ignored.
― x02 : Request to SPARC for power-off
― x03 : Request to SPARC for log collection
― x04 : Request to SPARC for information in the event log
― x05 : Request to SPARC to collect dump of XSCF memory
― x06 : Request to SPARC for event. nn indicates the event code. yy... indicates
the Detailed code byte 0-2.
C4:Panel Detailed code: x01mm0000
[: Panel Explanation: A panel operation event occurred. mm indicates the button operation
operation number.
event] The definition of mm is as follows:
― x01 : The POWER switch button was pressed in a short operation.
― x02 : The RESET switch button was pressed in a short operation.
― x03 : The Request switch button was pressed in a short operation.
― x81 : The POWER switch button was pressed for a long time.
― x83 : The Request switch button was pressed for a long time.
Detailed code: x02mm0000
Explanation: A panel operation event for the mode switch occurred. mm indicates the
mode switch operation number.
The definition of mm is as follows:
― x01 : The mode switch was set to maintenance mode.
― x40 : The mode switch was set to unlock mode.
― x80 : The mode switch was set to lock mode.
Detailed code: x03mmqq00
Explanation: A switch operation event for the remote panel occurred. mm indicates the
button operation number and qq indicates whether the operation was valid.
The definition of mm is as follows:
― x01 : The POWER switch button was pressed in a normal operation.
― x02 : The RESET switch button was pressed in a normal operation.
― x03 : The Request switch button was pressed in a normal operation.
― x81 : The POWER switch button was pressed for a long time.
The definition of qq is as follows:
― x01 : The operation was valid.
― x02 : The operation was not valid.
C5:RCI Detailed code: x01000000
[: RCI event] Explanation: Power-off request is sent to an IO device.
Detailed code: x02000000
Explanation: Switched to be the master of the RCI network.
Detailed code: x10nnnnnn nnnnnnnn nnnnnnnn nnnnnnnn
Explanation: The RCI sending event was executed. nn.. is packet data of RCI
communication.
Detailed code: x20nnnnnn nnnnnnnn nnnnnnnn nnnnnnnn
Explanation: The RCI receiving event was executed. nn.. is packet data of RCI
communication.
Detailed code: x30000000
Explanation: The RCI initial operation was executed.
Detailed code: x31000000 nn
Explanation: The RCI initial configuration was executed. nn is Node ID(the first 2
digits).
Detailed code: x32000000 nn
Explanation: The RCI initial configuration was executed again. nn is Node ID(the first 2
digits).
Detailed code: x3F0000rr
Explanation: The RCI configuration result was shown. nn is result value.
Detailed code: x80ppsstt
Explanation: The RCI device is recovered from failure state by retry. ppsstt indicates
the detailed information.
B-61
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C6:Setup Detailed code: xVV000000 nnnnnnnn nnnnnnnn
[:Setup- Explanation: An event, related to installation or replacement of hardware, occurred.
related] VV indicates the detailed event and nn.. indicates the serial number after replacement.
(0 at the SB-PANEL disagreement. )
The definition of VV is as follows:
― x01 : The SB was replaced with spare part.
― x02 : The panel was replaced with spare part.
― x80 : The SB-PANEL did not match.
C7:External Detailed code: xVVqq0000
[: Extended Explanation: An extended system status report event occurred. VV indicates the
system status detailed event and qq indicates the status code.
report] The definition of VV is as follows:
― x81 : "OBP complete" was reported.
― x82 : "Suspend start" was reported.
― x83 : "Suspend" was reported.
― x84 : "Resume" was reported.
The definition of qq is as follows:
― x00 : Normal
― x01 : Abnormal
C8:LogAnlyz Detailed code: x01qq0000
[: Hardware log Explanation: Hardware log analysis started. qq indicates the log category.
analysis] The definition of qq is as follows:
― x01 : Analysis was started by the log request.
― x02 : Fatal error log analysis was started.
Detailed code: x02qq0000 nnnnnnnn
Explanation: Hardware log analysis finished. qq indicates the end code.
The definition of qq is as follows:
― x01 : Normal end. nn... indicates the latch code.
― xFF : Abnormal end. nn... indicates the fault detection number.
Detailed code: x03qq0000 nnnnnnnn
Explanation: XSCF ignores events. qq indicates the source and nn... indicates the latch
code.
The definition of qq is as follows:
― x01 : XSCF does not take a log, because it's expected and igonoreable
problem.
― x02 : XSCF does not take a log, because attribute is inconsistent.
― x03 : The bit was disabled because of a receive_latch.
Detailed code: x04qqss00 nnnnnnnn
Explanation: A Resion code was detected. qq indicates a priority level from 1 to 99, ss
indicates the order of the detected Resion code from 1 to 50, and nn... indicates the latch
code.
C9:Tempinfo Detailed code: xVVqqppss jjkkllmm
[: Temperature Explanation: A change in temperature occurred. VV indicates the detailed event, qq
change event] indicates the inlet temperature, pp indicates SB temperature 1, ss indicates SB
temperature 2, and jj to mm indicate the temperature of CPU0 to CPU3.
The definition of VV is as follows:
― x02 : A high ambient temperature warning occurred.
― x04 : A low ambient temperature warning occurred.
― x06 : A high CPU temperature warning occurred.
― x07 : A high CPU temperature alarm occurred.
― x12 : Recovery from the high ambient temperature warning or low ambient
temperature warning was successful.
― x16 : Recovery from the CPU temperature warning was successful.
― x20 : Fan speed increased.
― x21 : Fan speed decreased.
Ca:SCFshell Detailed code: xVV000000
[: SCF shell Explanation: A XSCF shell command issued. VV indicates the detailed event.
event] The definition of VV is as follows:
― x00 : XSCF exited from maintenance mode.
― x01 : XSCF entered maintenance mode.
*el For the events indicated by Source codes X01 to X08, because RCI specific data is
displayed when the source of the event is the RCI device, the displayed data does not match the
definition shown in the table.
B-62
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
note:
About Source codes X01 to X3f, X80 is added to those codes when A shutdown request is
executed.
Information
The content of the event logs might be changed because of the function improvement.
B-63
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
B.4 XSCF Error Code Table
The table below lists the error codes that appear in error logs displayed when the show-error-
logs command is executed. Clicking a code enables you to jump to an explanation of the
appropriate log. For the error logs list, see "XSCF Error Log List and Actions" in Section B.1.
B-64
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
83000000 and up 830101FF 830104FF
83020100
8306010n
83080100
830B010n 830B0500 830B090n 830B0B00
830B0D0n 830B0F0n 830B110n 830B130n
830E000n
83100000 and up 8310010n 8310020n 8311010n 83120100
8313010n 8314010n
84000000 and up 84yyyy01 84yyyy02 84yyyy03 84yyyy04 84yyyy05
84yyyy06 84yyyy07 84yyyy08 84yyyy09
84yyyyF1 84yyyyF2 84yyyyF3 84yyyyF4
86000000 and up 86110000
B-65
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C3100000 and up C310000n C311000n C3120000 C313000n C314000n
C3160300 C3160400
C4000000 and up C4yyyy1n C4yyyy2n C4yyyy3n C4yyyy4n C4yyyy5n
C4yyyy6n C4yyyy7n C4yyyy8n C4yyyy9n
C6000000 and up C6110000
B-66
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Table B-4-3 OBP error code table
1100000n 1108020n 1108050n 1108TT00
120000FF 130000FF 140000FF 150000FF 160000FF
10000000and up 170000FF 180000FF 181000FF 182000FF
190000FF 1A0000FF 1B0000FF 1C00002n 1D00004n
1E0000XX 1F000044
230000FF 240000FF 250000FF 251000XX 252000XX
253000XX 254000XX 255000XX 256000XX 25700044
260000FF 261000XX 262000XX 263000XX
264000XX 265000XX 266000XX
20000000and up
270000FF 271000XX 272000XX 273000XX 274000XX
275000XX 276000XX 280000FF 281000FF
2A0000FF 2B0000FF 2C0000FF 2E0000FF 2E1000FF
2E2000FF
A000000n A010006n A02000XX A030001n
A0000000and up A040002n A050004n A0600044 A07000XX
A0900033 A0A00034
B-67
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
B-68
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Appendix C XSCF MIB
This chapter explains MIB(Management Infomation Base) that supported by the XSCF SNMP
agent function.
Contents:
C.1 MIB Object ID C-2
C.2 Standard MIB C-3
C.3 Fujitsu Extended MIB C-7
C.4 TRAP C-9
C-1
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C.1 MIB Object ID
The below explains the MIB object identifier supported by the XSCF.
C-2
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C.2 Standard MIB
The tables below explain the Standard MIB(MIB-Ⅱ) lists supported by the XSCF.
1. system group
Table C-1 system group
MIB OBJECT ID SYNTAX RW(*1)
sysDescr system.1 DisplayString R
sysObjectID system.2 ObjectID R
sysUpTime system.3 TimeTicks R
sysContact system.4 DisplayString R
sysName system.5 DisplayString R
sysLocation system.6 DisplayString R
sysServices system.7 INTEGER R
(*1):R:Read-Only、R/W:Read-Write、NA: Not-Access
2. interface group
Table C-2 interface group
MIB OBJECT ID SYNTAX RW
ifNumber interfaces.1 INTEGER R
ifTable interfaces.2 Aggregate NA
ifEntry ifTable.1 Aggregate NA
ifIndex ifEntry.1 INTEGER R
ifDescr ifEntry.2 DisplayString R
ifType ifEntry.3 INTEGER R
ifMtu ifEntry.4 INTEGER R
ifSpeed ifEntry.5 Gauge R
ifPhysAddress ifEntry.6 PhysAddress R
ifAdminStatus ifEntry.7 INTEGER R
ifOperStatus ifEntry.8 INTEGER R
ifLastChange ifEntry.9 TimeTicks R
ifInOctets ifEntry.10 Counter R
ifInUcastPkts ifEntry.11 Counter R
ifInNUcastPkts ifEntry.12 Counter R
ifInDiscards ifEntry.13 Counter R
ifInErrors ifEntry.14 Counter R
ifInUnknownProtos ifEntry.15 Counter R
ifOutOctets ifEntry.16 Counter R
ifOutUcastPkts ifEntry.17 Counter R
ifOutNUcastPkts ifEntry.18 Counter R
ifOutDiscards ifEntry.19 Counter R
ifOutErrors ifEntry.20 Counter R
ifOutQLen ifEntry.21 Gauge R
ifSpecific ifEntry.22 ObjectID R
3. at group
Table C-3 at group
MIB OBJECT ID SYNTAX RW
atTable at.1 Aggregate NA
atEntry atTable.1 Aggregate NA
atIfIndex atEntry.1 INTEGER R
atPhysAddress atEntry.2 PhysAddress R
atNetAddress atEntry.3 NetworkAddress R
C-3
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
4. ip group
Table C-4 ip group
MIB OBJECT ID SYNTAX RW
ipForwarding ip.1 INTEGER R
ipDefaultTTL ip.2 INTEGER R
ipInReceives ip.3 Counter R
ipInHdrErrors ip.4 Counter R
ipInAddrErrors ip.5 Counter R
ipForwDatagrams ip.6 Counter R
ipInUnknownProtos ip.7 Counter R
ipInDiscards ip.8 Counter R
ipInDelivers ip.9 Counter R
ipOutRequests ip.10 Counter R
ipOutDiscards ip.11 Counter R
ipOutNoRoutes ip.12 Counter R
ipReasmTimeout ip.13 INTEGER R
ipReasmReqds ip.14 Counter R
ipReasmOKs ip.15 Counter R
ipReasmFails ip.16 Counter R
ipFragOKs ip.17 Counter R
ipFragFails ip.18 Counter R
ipFragCreates ip.19 Counter R
ipAddrTable ip.20 Aggregate NA
ipAddrEntry ipAddrTable.1 Aggregate NA
ipAdEntAddr ipAddrEntry.1 IpAddress R
ipAdEntIfIndex ipAddrEntry.2 INTEGER R
ipAdEntNetMask ipAddrEntry.3 IpAddress R
ipAdEntBcastAddr ipAddrEntry.4 INTEGER R
ipAdEntReasmMaxSize ipAddrEntry.5 INTEGER R
ipRouteTable ip.21 Aggregate NA
ipRouteEntry ipRouteTable.1 Aggregate NA
ipRouteDest ipRouteEntry.1 IpAddress R
ipRouteIfIndex ipRouteEntry.2 INTEGER R
ipRouteMetric1 ipRouteEntry.3 INTEGER R
ipRouteMetric2 ipRouteEntry.4 INTEGER R
ipRouteMetric3 ipRouteEntry.5 INTEGER R
ipRouteMetric4 ipRouteEntry.6 INTEGER R
ipRouteNextHop ipRouteEntry.7 IpAddress R
ipRouteType ipRouteEntry.8 INTEGER R
ipRouteProto ipRouteEntry.9 INTEGER R
ipRouteAge ipRouteEntry.10 INTEGER R
ipRouteMask ipRouteEntry.11 IpAddress R
ipRouteMetric5 ipRouteEntry.12 INTEGER R
ipRouteInfo ipRouteEntry.13 ObjectID R
ipNetToMediaTable ip.22 Aggregate NA
ipNetToMediaEntry ipNetToMediaTable.1 Aggregate NA
ipNetToMediaIfIndex ipNetToMediaEntry.1 INTEGER R
ipNetToMediaPhysAddress ipNetToMediaEntry.2 PhysAddress R
ipNetToMediaNetAddress ipNetToMediaEntry.3 IpAddress R
ipNetToMediaType ipNetToMediaEntry.4 INTEGER R
C-4
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
5. icmp group
Table C-5 icmp group
MIB OBJECT ID SYNTAX RW
icmpInMsgs icmp.1 Counter R
icmpInErrors icmp.2 Counter R
icmpInDestUnreachs icmp.3 Counter R
icmpInTimeExcds icmp.4 Counter R
icmpInParmProbs icmp.5 Counter R
icmpInSrcQuenchs icmp.6 Counter R
icmpInRedirects icmp.7 Counter R
icmpInEchos icmp.8 Counter R
icmpInEchoReps icmp.9 Counter R
icmpInTimestamps icmp.10 Counter R
icmpInTimestampReps icmp.11 Counter R
icmpInAddrMasks icmp.12 Counter R
icmpInAddrMaskReps icmp.13 Counter R
icmpOutMsgs icmp.14 Counter R
icmpOutErrors icmp.15 Counter R
icmpOutDestUnreachs icmp.16 Counter R
icmpOutTimeExcds icmp.17 Counter R
icmpOutParmProbs icmp.18 Counter R
icmpOutSrcQuenchs icmp.19 Counter R
icmpOutRedirects icmp.20 Counter R
icmpOutEchos icmp.21 Counter R
icmpOutEchoReps icmp.22 Counter R
icmpOutTimestamps icmp.23 Counter R
icmpOutTimestampReps icmp.24 Counter R
icmpOutAddrMasks icmp.25 Counter R
icmpOutAddrMaskReps icmp.26 Counter R
6. tcp group
Table C-6 tcp group
MIB OBJECT ID SYNTAX RW
tcpRtoAlgorithm tcp.1 INTEGER R
tcpRtoMin tcp.2 INTEGER R
tcpRtoMax tcp.3 INTEGER R
tcpMaxConn tcp.4 INTEGER R
tcpActiveOpens tcp.5 Counter R
tcpPassiveOpens tcp.6 Counter R
tcpAttemptFails tcp.7 Counter R
tcpEstabResets tcp.8 Counter R
tcpCurrEstab tcp.9 Gauge R
tcpInSegs tcp.10 Counter R
tcpOutSegs tcp.11 Counter R
tcpRetransSegs tcp.12 Counter R
tcpConnTable tcp.13 Aggregate NA
tcpConnEntry tcpConnTable.1 Aggregate NA
tcpConnState tcpConnEntry.1 INTEGER R
tcpConnLocalAddress tcpConnEntry.2 IpAddress R
tcpConnLocalPort tcpConnEntry.3 INTEGER R
tcpConnRemAddress tcpConnEntry.4 IpAddress R
tcpConnRemPort tcpConnEntry.5 INTEGER R
tcpInErrs tcp.14 Counter R
tcpOutRsts tcp.15 Counter R
C-5
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
7. udp group
Table C-7 udp group
MIB OBJECT ID SYNTAX RW
udpInDatagrams udp.1 Counter R
udpNoPorts udp.2 Counter R
udpInErrors udp.3 Counter R
udpOutDatagrams udp.4 Counter R
udpTable udp.5 Aggregate NA
udpEntry udpTable.1 Aggregate NA
udpLocalAddress udpEntry.1 IpAddress R
udpLocalPort udpEntry.2 INTEGER R
8. snmp group
Table C-8 snmp group
MIB OBJECT ID SYNTAX RW
snmpInPkts snmp.1 Counter R
snmpOutPkts snmp.2 Counter R
snmpInBadVersions snmp.3 Counter R
snmpInBadCommunityNames snmp.4 Counter R
snmpInBadCommunityUses snmp.5 Counter R
snmpInASNParseErrs snmp.6 Counter R
snmpInTotalReqVars snmp.13 Counter R
snmpInTotalSetVars snmp.14 Counter R
snmpInGetRequests snmp.15 Counter R
snmpInGetNexts snmp.16 Counter R
snmpInSetRequests snmp.17 Counter R
snmpInGetResponses snmp.18 Counter R
snmpInTraps snmp.19 Counter R
snmpOutTooBigs snmp.20 Counter R
snmpOutNoSuchNames snmp.21 Counter R
snmpOutBadValues snmp.22 Counter R
snmpOutGenErrs snmp.24 Counter R
snmpOutGetResponses snmp.28 Counter R
snmpOutTraps snmp.29 Counter R
snmpEnableAuthenTraps snmp.30 INTEGER R
C-6
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C.3 Fujitsu Extended MIB
The tables below explain the Fujitsu extended MIB lists supported by the XSCF.
1. scfInfo group s
Table C-9 scfInfo group
MIB OBJECT ID SYNTAX R CONTENT
W
scfMachineType scfInfo.1 DisplayString R Model name
scfNumberOfCpu scfInfo.2 INTEGER R Number of
installing CPU
scfSysSerial scfInfo.3 DisplayString R Serial Number
scfFirmVersion scfInfo.4 DisplayString R Firmware version
scfHCPVersion scfInfo.5 DisplayString R HCP version
scfServerUpTime scfInfo.6 TimeTicks R Agent Uptime
scfHostID scfInfo.7 DisplayString R Host ID
scfServerID scfInfo.8 DisplayString R Server ID
2. scfState group
Table C-10 scfState group
MIB OBJECT ID SYNTAX R CONTENT
W
scfHWErrLevel scfState.1 DisplayString R Faulty-parts state
scfOSStatus scfState.2 DisplayString R OS state
scfDisplay scfState.3 DisplayString R Contents of Remote
panel message
scfModeSwitch scfState.4 DisplayString R Mode switch
3. scfTrapParams group
Table C-11 scfTrapParams group
MIB OBJECT ID SYNTAX R CONTENT
W
scfServerName scfTrapParams.1 DisplayString R Host name(OS)
scfTrapTime scfTrapParams.2 TimeTicks R scfServerUpTime
value of trap
occurred
scfHWErrComme scfTrapParams.3 DisplayString R Error
nt information(*1)
scfHWConfAddr scfTrapParams.4 DisplayString R Faulty-parts
The explanation of the Error code and Error message, see "Appendix B XSCF Log
Information".
C-7
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
4. scfMonitor group
Table C-12 scfMonitor group
MIB OBJECT ID SYNTAX R CONTENT
W
scfTemperatureTable scfMonitor.1 Aggregate NA MIB table of temperature
scfTemperatureEntry scfTemperatureTable.1 Aggregate NA
scfTemperaturePartsName scfTemperatureEntry.1 INTEGER R parts name(*1)
scfTemperaturePartsNumber scfTemperatureEntry.2 INTEGER R parts number(*1)
scfTemperatureSubIndex scfTemperatureEntry.3 INTEGER R senser number(*2)
scfTemperatureStatus scfTemperatureEntry.4 INTEGER R status of value(*3)
value (unit:0.1 degrees
scfTemperatureValue scfTemperatureEntry.5 INTEGER R C)
scfVoltageTable scfMonitor.2 Aggregate NA MIB table of voltage
scfVoltageEntry scfVoltageTable.1 Aggregate NA
scfVoltagePartsName scfVoltageEntry.1 INTEGER R parts name(*1)
scfVoltagePartsNumber scfVoltageEntry.2 INTEGER R parts number(*1)
scfVoltageSubIndex scfVoltageEntry.3 INTEGER R senser number(*2)
scfVoltageStatus scfVoltageEntry.4 INTEGER R status of value(*3)
scfVoltageValue scfVoltageEntry.5 INTEGER R value (unit:0.01 V)
MIB table of FAN rotation
scfRotationTable scfMonitor.3 Aggregate NA rate
scfRotationEntry scfRotationTable.1 Aggregate NA
scfRotationPartsName scfRotationEntry.1 INTEGER R parts name(*1)
scfRotationPartsNumber scfRotationEntry.2 INTEGER R parts number(*1)
scfRotationSubIndex scfRotationEntry.3 INTEGER R senser number(*2)
scfRotationStatus scfRotationEntry.4 INTEGER R status of value(*3)
scfRotationValue scfRotationEntry.5 INTEGER R value (unit:1 rpm)
C-8
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C.4 TRAP
The tables below explain the Standard TRAP and the Fujitsu extended TRAP.
1. Standard TRAP
(*1): The fatal problem that the system cannot continue operation.
(*2): The slight problem that the system can continue operation.
C-9
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
C-10
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
Appendix D Troubleshooting
This chapter describes problems that can occur during use of the XSCF console or during
operation of the system and provides solutions for them.
Contents:
D.1 Troubleshooting XSCF D-2
D.2 Troubleshooting the Server While XSCF Is Being Used D-5
D-1
All Rights Reserved,Copyright (C) FUJITSU LINITED 2003
D.1 Troubleshooting XSCF
This section describes problems that can occur while XSCF is being used and provides
solutions for them.
D-2
All Rights Reserved,Copyright (C) FUJITSU LINITED 2003
A mail report was not received from XSCF
● XSCF does not report all events. It sends mail for faulty parts, an authentication failure
event, and testing. See the event logs list in "Appendix B XSCF Log Information" to
check if the expected report is in the error log or if the report is an event that is reported in
the event log.
Could not access the top page of the XSCF Web function
● Check whether the settings for the XSCF Web function have been enabled.
● Check whether the correct URL was input. (For example, "s" of "https" is not added.)
● Check whether an allowed IP address was specified.
● Check whether SSL and TLS are enabling in the browser settings.
Could not display the login screen of the XSCF Web function
● If pressing the login button on the top page of the XSCF Web function fails to display the
login screen, JavaScript may be disabled in the browser settings. Enable JavaScript and
log in again.
● When the creating of Pop-up window is prohibited in the browser settings, XSCF Web
function fails to display the login screen. Enable it and log in again.
Failed the first access to the XSCF Web function after log in
● Check whether the browser accepts the cookie in its settings.
The Web screen of the XSCF Web function is not displayed correctly
● The screen might not be displayed correctly because of the version of the browser. See
"Supported browsers" in "Chapter5 How to Use the XSCF Web Function" and switch to
the latest browser.
D-3
All Rights Reserved,Copyright (C) FUJITSU LINITED 2003
The XSCF shell was forcibly terminated while it was being used
● After login to the XSCF shell, if there is no activity for a predetermined time, XSCF
automatically terminates the shell. When the time monitoring function has been enabled
and a time has been specified in the XSCF settings, forced termination occurs if the time
elapses.
Other problems
● Contact the system administrator. When an XSCF dump is required, use the Machine
Administration Menu. For information about obtaining a dump, see "Appendix 9 XSCF
Firmware Upgrade and Dump".
D-4
All Rights Reserved,Copyright (C) FUJITSU LINITED 2003
D.2 Troubleshooting the Server While XSCF Is Being
Used
This section explains how to effectively use XSCF when a problem such as no response from
the server occurs on the server, or when a panic occurs.
Before contacting service, first try the procedure given below. This procedure may not only be
helpful in solving the problem but also could eliminate the need to make an inquiry.
1. If the server does not respond, set the mode switch on the operating panel to
MAINTENANCE mode.
2. Confirmed the system by either of the following methods.
● When you cannot use the XSCF Web function nor the XSCF shell via telnet or serial port.
a. Change the mode switch on front panel to "MAINTENANCE" position.
b. Connect a terminal to the XSCF's serial port. Then Input the login keyword("~.") to XSCF
shell. This combination is the default value. For changing the keyword, see "Chapter6
How to Use the XSCF Command Shell".
c. The system message is displayed with the initialization message before the login prompt
of the XSCF shell is displayed. When the hardware error has been detected by XSCF, any
trouble is notified by this system message. So please deal based on the message.
● .When you can use the XSCF Web function or the XSCF shell via telnet or serial port.
3. Please restart the system if you cannot find out any problem in the above-mentioned
check points.
4. If you found any hardware failure, take action according to the method written on appendix
B, such as, replace a part with using Machine Administration Menu.
Next: "Glossary"
D-5
All Rights Reserved,Copyright (C) FUJITSU LINITED 2003
D-6
All Rights Reserved,Copyright (C) FUJITSU LINITED 2003
Glossary
A:
[ACK] An abbreviation of acknowledgement. ACK is a positive response transmitted from the
sending PC to the receiving PC in communication between PCs. It is transmitted, for example,
when a data transfer has ended successfully.
When all data has been received without error, the receiving PC sends an ACK packet.
Conversely, if corrupted data is received, the receiving PC requests retransmission.
[ACK timeout] The time allowed for an acknowledgement to be sent from the sending PC to the
receiving PC.
[APCS] Automatic power control. The generic term for functions of PRIMEPOWER series
machines supported by the Enhanced Support Facility (ESF) that control power supply schedules.
B:
[Bank] An area used when a physical memory is divided into areas for management purposes. A
bank required for an area specified in the address space is allocated each time it is used. The
bank must be changed if a different bank is accessed.
C:
[CCU] An abbreviation of Console Connection Unit. A console connection unit converts the input
and output of a serial-connected console for the LAN and converts the transmission data from a
LAN-connected terminal.
[Checksum] A method used to check for corrupted data. The data is sent with a sum. The
receiving end calculates the sum of the received data and compares it with the sum calculated at
the sending end.
[CPUDDC] The DDC for the CPU core. CPUDDC is mounted on the CPU module.
D:
[DDC] An abbreviation of DC-DC converter. A DDC converts one direct-current voltage to another
direct-current voltage.
W-1
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
[DIMM] An abbreviation of dual in-line memory module. DIMMs are memory modules that are
mounted on the motherboard.
E:
[ECC] An abbreviation of Error Check and Correction. ECC is a mechanism for monitoring
memory operation. When ECC detects a one-bit memory error, it automatically corrects the error
and operation continues. ECC also detects two-bit memory errors.
[External power controller] A controller that provides, among other functions, a conversion
function between the power/environment control interface (RCI) and other power/environment
control interfaces (including power control, status monitoring, and disaster-prevention panel
control).
F:
[FAN-JT] A fan board.
[FMEM] An abbreviation of flash memory. FMEM is a nonvolatile PROM on which data can be
erased electrically either by sector (block) or for the entire chip. Nonvolatile memory retains data
when power is turned off.
H:
[HPC] An abbreviation of Hot Plug Controller. The Hot plug controller of component that you can
exchange and detach without system shutdown or reboot.
I:
[IDE] Bus of easy circuit composition to connect hard disk or CD-ROM drive.
J:
[JTAG] An abbreviation of Joint Test Action Group. It generally indicates the boundary scan
architecture, of which test method was standardized as EEE1149.1, and its serial port.
The boundary scan is the architecture that allocates between the core logic and the pin a register
called cell equivalent to the test probe and that, if it is a shift register, enters the input signal from
the shift register and examines the output result.
W-2
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
N:
[Neuron] The component in which the RCI interface controller operates.
[NVRAM] An abbreviation of nonvolatile RAM. For ordinary RAM, its contents are lost when
power is no longer supplied. NVRAM, however, retains its contents when power is turned off.
O:
[OBP-FMEM] An FMEM for the OBP. See FMEM.
P:
[Panel] A part, on the front of a server, that contains the power switch button, LEDs, and similar
items used by the operator.
[PCI] An abbreviation of Peripheral Component Interface, which is an IEEE standard. The PCI is
one of the standards used for installation of expansion boards in a PC or workstation and often
indicates the location of the expansion board on the motherboard.
[PROM] An abbreviation of programmable ROM. PROM is ROM to which data can be written.
R:
[RAS] An abbreviation of reliability, availability, and serviceability.
[RAS-DB] An XSCF firmware resource that implements the RAS function in XSCF.
[RCI] An abbreviation of Remote Cabinet Interface. The RCI is the power and system control
interface that connects units, including processors and expansion file units, and performs such
functions as power supply interlock and alarm notification and recognition.
[RCI address] The address by which each device used by the RCI is recognized.
[RCI device or RCI I/O] A device connected by the RCI. The server, external power controller,
disk drive, and circuit switch are some of the devices connected by the RCI.
W-3
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
[RCI-Neuron] A chip that controls the RCI. Neuron.
W-4
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
[Read-only console] An OS console used for display only. On a terminal connected to the SCF-
LAN, starting telnet and specifying port number 8011 establishes a connection. This port can be
used by up to two users per server. Since the Read-only console is independent of the console
switching executed by the XSCF command, the console display is available at all while the OS is
running.
S:
[SB] An abbreviation of system board.
[SC] An abbreviation of system controller. The SC controls the coherency of the cache among
CPUs.
[SCF] An abbreviation of System Control Facility. The SCF is the system monitoring and control
facility. It is the same facility as XSCF.
[SMTP] An abbreviation of Simple Mail Transfer Protocol. SMTP is a protocol for sending e-mail
on the Internet or an intranet. It is used to transmit mail between servers and to send mail from a
client to the server.
[SNMP] An abbreviation of Simple Network Manager Protocol. SNMP is a protocol for network
management that enables the SNMP manager to centrally manage the operating status and fault
status of terminals on the network.
[SSL] An abbreviation of secure socket layer. A security mechanism that encrypts data that will be
transmitted on the Internet. Netscape Navigator and Microsoft Internet Explorer support SSL.
When a Web page ready for SSL is accessed, the key symbol in the browser is locked and a
warning message is displayed.
W-5
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
[Standard console] An OS console on which input and output are enabled. The OS console can
be used in both an SCF-LAN connection and a serial connection. On a terminal connected to the
SCF-LAN, starting telnet and specifying port number 23 establishes a connection. The standard
console can also be used by connecting a PC to the serial port and turning on the server. Only one
user per server can use the LAN port of the standard console. An XSCF shell command enables
or disables the LAN port to allow the console output destination to be either the SCF-LAN or the
serial port.
[System control bus] The bus used for communication between system components and for
monitoring of the environment.
T:
[TTY] An abbreviation of teletypewriter. Generally a unit for displaying input and output
characters on the console or its virtual feature simulated by hardware or software.
[TTY-A] The serial port usually used for the standard console and XSCF shell.
[TTY-B] The serial port usually used for a serially-connected unit such as the external clock
device.
U:
[U2-Cache] The secondary cache of a CPU.
[U2P] An abbreviation of UPA to PCI. The LSI circuitry between the UPA bus and the PCI bus.
[UPA] An abbreviation of Ultra Port Architecture. UPA is the protocol specifications for connecting
the CPU, IO, memory, and other components. It is used as the interface between the CPU and SC,
U2P and the SC, and the SC and XB.
[UPS] An abbreviation of uninterruptible power supply unit. An uninterruptible power supply unit
is connected for backup power control purposes in the event of a power outage. This equipment
or unit ensures the continuous supply of power, without service interruption (no interruptions of
communication), when the normal power equipment fails or a blackout occurs.
W:
[WEBDATA] An XSCF firmware resources that implements the XSCF Web function.
[WDT] An abbreviation of watchdog timer. The watchdog timer, built into the CPU, checks
whether the system operating status is normal. If it detects abnormal operation, it immediately
issues an interrupt to the CPU to notify it of the abnormal condition.
W-6
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
X:
[XB] An abbreviation of crossbar. XB is a data crossbar that connects the CPU and memory, U2P
and memory, and connects the CPU and U2P.
[XIR] An abbreviation of externally initiated reset. A XIR resets the server CPU.
[XSCF] An abbreviation of Extended System Control Facility. XSCF is a system monitor and
control facility. It is also referred to as the SCF.
W-7
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003
W-8
All Rights Reserved,Copyright (C) FUJITSU LIMITED 2003