Content Analysis S200, S400, S500: Quick Start Guide
Content Analysis S200, S400, S500: Quick Start Guide
01 Unpack the Appliance c. Connect the Content Analysis appliance’s DB9 serial port to a serial terminal or workstation
with terminal emulation software. Use the included null-modem cable. The serial connection
d. Power on the appliance (if it is not already powered on) and, when prompted, press Enter
three times.
Verify the contents of the shipping package for the Content Analysis appliance. is used to perform the appliance’s initial configuration. e. When prompted, enter network configuration parameters. If the appliance is connected to
d. For CAS S500 appliances, attach the lug- a network, the Initial Configuration Wizard attempts to verify the DNS server address and
CAS S200 CAS S400 CAS S500
equipped end of the included grounding PS 2 auto-detect link settings.
AC power cords (number included) 1 2 2
wire (10 AWG) to both grounding studs IOIOI BMC MGMT f. When prompted, assign a Username and Password to the administrator account.
Grounding hardware √ 7:
on the appliance, securing it with the
Null-modem serial cable √ √ √ Note: Following the initial configuration, the System Status LED blinks amber, indicating the
star washers and M5 nuts. Attach the
Two/four post slide-rail kit Optional √ √ appliance has not yet been licensed (see Step 5).
other end of the grounding wire to a
Rack-mount ears √ √ proper earth-ground.
02 Connect Cables
will receive an e-fulfillment letter containing your appliance’s serial number and activation
code for subscription services. All Content Analysis components require a license to operate.
After you have verified that the base license has been installed, review the subscription
To verify the appliance is operational:
components and activate them as necessary.
Symantec recommends plugging in cables, verifying LEDs, and configuring and licensing a. Confirm the appliance’s power cords are securely connected to a power source.
To register the Content Analysis appliance:
the appliance before rack-mounting it. If you would rather rack-mount the appliance before b. If the appliance does not automatically power on, press the rear soft power switch.
performing configuration tasks, skip to Step 7—Rack-Mount the Appliance. a. Go to https://www.mysymantec.com/ and log in with MySymantec credentials.
Note: The state of the appliance’s soft power switch (on or off) is retained when power is
b. Choose Licensing > Network Protection (Blue Coat) Licensing.
Content Analysis Management removed. This may necessitate pressing the power switch when reapplying power to the
Appliance Network appliance. c. On the Network Protection Licensing Portal, on the left side, select Content Analysis Sys-
tem and click Software Anti-Virus Activation.
c. As the appliance boots, verify the following:
d. Enter the Appliance Serial Number and Activation Code (included in your e-fulfillment
oo The Power LED turns amber.
letter) and click Submit.
oo Near the end of the boot cycle, the Power LED alternates between amber and green,
e. When prompted with the Symantec License Agreement, select I Accept and click Submit.
Switch Router indicating an unconfigured state.
The license is activated and the portal displays information about the license.
oo Following the initial configuration (see Step 4), the Power LED turns green. In addition, the
LCD displays system statistics, which can be scrolled through with the Left/Right Arrows. To download and install the license:
Main Site ProxySG Appliance
The front-panel LEDs indicate the following states:: a. Open a browser and enter the appliance’s IP address and port number. For example,
LAN an IP address of 192.168.2.42 with a port number of 8082 (the default) translates to:
The following procedure describes a typical deployment for Content Analysis and ProxySG
oo Power LED ( •) Off: Powered off https://192.168.2.42:8082
appliances (as shown in the above illustration). For information on other deployments, see the
( •) Amber: Booting b. When prompted, enter the administrator Username and Password specified during the
Administration & Reference WebGuide.
( •) Amber/green alternating: Unconfigured initial configuration, then click Login.
( •) Green: Powered on and configured c. In the web management console, choose System > Licensing.
oo Sys Status LED (•) Off: No status
Note: Network cables are not included with the appliance. Make sure to use only straight-
d. Click Download License from Symantec. The appliance confirms the download and installation.
(•) Green: Healthy
through Ethernet cables. For 1000Base-T operation, Symantec recommends Category 5E cables
or better (Category 6 or 6A) for distances of 330 feet (100 meters).
(•) Amber: Warning To activate license components:
To deploy the Content Analysis appliance and connect its cables: a. In the web management console, choose System > Licensing. The Licensing Activation sec-
a. Deploy the ProxySG appliance:
*
( ) Amber blinking: Critical (or not licensed)
tion displays the available license components, their status, and whether they are active.
b. Deploy the Content Analysis appliance: a. Confirm the appliance’s DB9 serial port is connected to a serial terminal or workstation with a. Log in to the Content Analysis CLI (see Step 4).
oo Connect the Content Analysis appliance’s 1:0 port to the ProxySG appliance with a terminal emulation software. b. When prompted, to access the CLI, press: 1
network cable. The appliance auto-negotiates the 10/100/1000 Base-T speed and duplex b. Open a terminal emulation program such as Microsoft HyperTerminal®, PuTTY, Tera Term, or c. To access privileged commands, enter: enable
settings. ProComm™. d. When prompted, enter the enable Password specified during the initial configuration.
oo Connect the Content Analysis appliance’s SYS MGMT 0:0 port to the router leading to c. Configure the terminal emulation software to use the following settings: e. Enter: shutdown
the management network with a network cable. oo Baud rate: 9600 bps oo Data bits: 1 Warning: Do not power off the appliance with the soft power switch or by removing the power
Note: The Content Analysis appliance must be managed through the SYS MGMT 0:0 port. oo Parity: none oo Stops bits: 8 cables! Abruptly removing power can result in irreparable data loss. Always use the shutdown
The SYS MGMT port is identified as simply 0:0 during initial configuration. command from the CLI to power off the appliance.
oo Flow control: none
CAS S200, CAS S400, CAS S500 Quick Start Guide Page 2
07 Rack-Mount the Appliance c. For CAS S200 and CAS S400 appliances, install the two rack ears. Align them with the mount-
ing posts on the chassis sides near the front of the appliance and secure them with the included
e. Install the appliance in the rack:
oo Align the inner rails attached to the appliance with the slide-rails in the rack and slide the
The slide-rail mounting kit included with the CAS S400 and CAS S500 appliances (available as fasteners. appliance half-way into the track.
an option for CAS S200 appliances) allows the appliance to be rack-mounted in a two- or -four-
post equipment rack. The slide-rail kit includes the following parts:
Inner Rail (2)
Note: The following procedure documents how to install the appliance in a four-post equipment
rack. For comprehensive information on rack-mounting the appliance, including other oo Press the gray locking tabs on the inner rails to slide the appliance all the way into the rack.
configurations, see the S-Series Maintenance and Upgrade Guide at: Rail_C oo Slide the appliance out of the rack, far enough to access the rack screws. Fully tighten
http://www.symantec.com/docs/DOC9795 the rack screws for the front and rear brackets to secure the slide-rails to the rack.
Rail_A
oo Gently push the appliance all the way to the back of the rack and tighten the
thumbscrews on the retaining ears to prevent the appliance from sliding out.
CAUTION:
f. Reconnect the cables as documented in Step 2—Connect Cables and verify the appliance is
Before rack-mounting the appliance:
functioning as in Step 3—Power On the Appliance and Verify LEDs.
oo Power off the appliance and disconnect all cables.
Note: The precise attachment location of the screws will depend on how far Rail_C will
oo Verify that the weight of the system does not exceed the rack’s extend or retract to fit the rack. It may be necessary to remove Rail_C from Rail_A to
fully populated weight limit. For more information, refer to the determine the proper installation length.
manufacturer’s instructions included with the rack. Technical Support
oo Install the assembled slide-rails in the rack:
oo For weight stability, load the rack from the bottom up.
• Secure the front bracket for Rail_A to the outside front of the rack using two rack oo Contact Information
oo Read the “Rack Mount Warnings” section of the Safety and https://support.symantec.com/en_US/contact-support.html
screws. Do not yet fully tighten the screws. You will do so after the appliance is
Regulatory Compliance Guide.
installed in the rack. oo MySymantec
oo Take adequate safety and grounding measures to avoid creating an https://www.mysymantec.com
• Extend or retract Rail_C to align the rear bracket with the outside rear of the rack.
electrical shock hazard and to prevent bodily injury.
Secure the bracket with two M3 screws. Do not yet fully tighten the screws. You will
do so after the appliance is installed in the rack. Documentation
• Tighten the side-mounting screws for Rail_C.
Content Analysis Software Documentation
To install the appliance in a four-post equipment rack: • Verify the slide-rail assemblies are installed at the same rack eight. oo https://support.symantec.com/en_US/Documentation.html
a. Disassemble the two slide-rail assemblies: On the Documentation page, type “Content Analysis Software” in the
oo Fully extend each slide-rail by sliding out the inner rails until they reach the stop. Product Name and select the software version from the drop-down menu
oo Release the white slide latches (toward the rear of the inner rails) and slide the inner rails to see the available Administration & Reference WebGuide, Command Line
all the way out. Interface Guide, and more.
oo Slide-rails are symmetrical and can be used with either side of the chassis. Appliance Documentation
b. Attach the two inner rails to the appliance: oo S-Series Maintenance and Upgrade Guide
http://www.symantec.com/docs/DOC9795
oo Align each inner rail to the mounting posts on each side of the chassis. Slide the rail
toward either the front (CAS S200 and CAS S400) or rear (CAS S500) of the chassis until oo S200 Series Safety and Regulatory Compliance Guide
each of the mounting posts snap into place. http://www.symantec.com/docs/DOC10311
oo S400 Series Safety and Regulatory Compliance Guide
http://www.symantec.com/docs/DOC9996
oo S500 Series Safety and Regulatory Compliance Guide
http://www.symantec.com/docs/DOC10248
Rail_C
Copyright © 2018 Symantec Corp. All rights reserved. Symantec, the Symantec Logo, the Checkmark Logo, Blue Coat, and the Blue Coat logo are trademarks or registered trademarks of Symantec Corp. or its affiliates in the U.S. and other countries. Other names may be trademarks of their respective owners. This document is provided for informational purposes only and is not intended as advertising. All warranties relating to the information in this
document, either express or implied, are disclaimed to the maximum extent allowed by law. The information in this document is subject to change without notice. Part Number: 231-03320 Rev A.0
THE DOCUMENTATION IS PROVIDED “AS IS” AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. SYMANTEC CORPORATION SHALL NOT BE LIABLE FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, PERFORMANCE, OR USE OF THIS DOCUMENTATION. THE INFORMATION CONTAINED IN THIS DOCUMENTATION IS SUBJECT TO CHANGE WITHOUT NOTICE. SYMANTEC CORPORATION PRODUCTS, TECHNICAL SERVICES, AND ANY OTHER TECHNICAL DATA REFERENCED IN THIS DOCUMENT ARE SUBJECT TO U.S. EXPORT CONTROL AND SANCTIONS LAWS, REGULATIONS AND
REQUIREMENTS, AND MAY BE SUBJECT TO EXPORT OR IMPORT REGULATIONS IN OTHER COUNTRIES. YOU AGREE TO COMPLY STRICTLY WITH THESE LAWS, REGULATIONS AND REQUIREMENTS, AND ACKNOWLEDGE THAT YOU HAVE THE RESPONSIBILITY TO OBTAIN ANY LICENSES, PERMITS OR OTHER APPROVALS THAT MAY BE REQUIRED IN ORDER TO EXPORT, RE-EXPORT, TRANSFER IN COUNTRY OR IMPORT AFTER DELIVERY TO YOU.