100% found this document useful (1 vote)
700 views13 pages

Ogiq F8: GE Healthcare

The document describes the GE Healthcare LOGIQ F8 ultrasound system. The LOGIQ F8 is a multipurpose system designed for abdominal, obstetrical, gynecological and other applications. It features a 19-inch high resolution LCD monitor on an articulating arm, 8 TGC pods, and an 8.4-inch touch screen. The system offers B-mode, M-mode, color Doppler, spectral Doppler, and 4D imaging capabilities along with various advanced imaging modes and calculation packages. Peripheral options include thermal printers, a mobile printer, and storage devices.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
700 views13 pages

Ogiq F8: GE Healthcare

The document describes the GE Healthcare LOGIQ F8 ultrasound system. The LOGIQ F8 is a multipurpose system designed for abdominal, obstetrical, gynecological and other applications. It features a 19-inch high resolution LCD monitor on an articulating arm, 8 TGC pods, and an 8.4-inch touch screen. The system offers B-mode, M-mode, color Doppler, spectral Doppler, and 4D imaging capabilities along with various advanced imaging modes and calculation packages. Peripheral options include thermal printers, a mobile printer, and storage devices.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

GE Healthcare

LOGIQ F8
Version 1.0

Ver Integrated HDD (500GB)


LOGIQ F8 Ultrasound System Integrated speakers
The LOGIQ* F8 is the multipurpose ultrasound imaging Probe holders, removable for clean and washing
system designed for Abdominal, Obstetrical, Gel holder, removable for clean and washing
Gynecological, Small Parts, Musculoskeletal, Front and rear handles
Vascular/Peripheral Vascular, Urological, Pediatric, Probe Cable tray
Transcranial and Cardiac applications Probe Cable management slots
Easily removable air filters
Wheels:
 Wheel diameter: 125mm
 Locking mechanism that provides rolling lock and
caster swivel lock

User interface
Operator keyboard
Ergonomic full size keyboard
8 TGC pods
8.4” (213.4 mm) LCD touch screen

General specifications Monitor


Dimensions and weight 19” (482.6 mm) high-resolution LCD
Height with 19”LCD Articulating monitor arm
 Max 1495mm (58.9 in) Tilt/Rotate/Translate
 Min 1410mm (55.5 in) • Tilt angle: +25˚/–90˚
Width • Rotate angle: ±90˚
 Keyboard: 500 mm (19.7 in) • Translate horizontal 800 mm
 Caster: 720 mm (28.3 in) • Translate vertical 164.5 mm
Depth Fold-down and lock mechanism for transportation
 Maximum: 810 mm (31.9 in) Brightness and contrast adjustment
 Caster: 800 mm (31.5 in)
Weight (no Peripherals): 58 kg System overview
Applications
Electrical power Abdominal
Voltage 100-240 VAC Obstetrical
Frequency 50/60 Hz Gynecological
Power consumption maximum of 400 VA with Small Parts
peripherals Musculoskeletal
Vascular/ Peripheral Vascular
Console design Urological
Max 4 active probe ports Pediatric

1
GE Healthcare

LOGIQ F8
Version 1.0

Transcranial Ver Image Archive on integrated HDD


Cardiac Raw Data Analysis
Scan Assistant
Scanning methods Scan Coach
Electronic Convex Real-time automatic Doppler calculations
Electronic Linear OB Calculations
Electronic Micro Convex Fetal Trending
Electronic Sector Multigestational Calculations
Real Time 4D Volume Sweep Hip Dysplasia Calculations
Gynecological Calculations
Transducer types Vascular Calculations
Convex Array Urological Calculations
Linear Array Renal Calculations
Microconvex Array Cardiac Calculations
Sector Phased Array Remote capability: InSite ExC
Volume Probes (4D) On-board reporting package
MPEGVue
Operating modes Network Storage
B-Mode
Coded Phase Inversion Harmonic Imaging System Options
M-Mode Elastography
Color M Mode LOGIQView
Color Flow Mode (CFM) Auto IMT
Power Doppler Imaging (PDI) CW Doppler
Directional PDI Anatomical M-Mode
PW Doppler with High PRF Tissue Velocity Imaging (TVI) with Q-Analysis
Anatomical M-Mode (Option) Easy 3D
CW Doppler Mode (Option) Static 3D/ Realtime 4D
LOGIQView (Option) DICOM 3.0 Connectivity
TVI Mode (Option) Extra probe holder
3D/4D Volume Modes (Option) Paper Tray

System standard features Peripheral Options


AO (Automatic Optimization) Fixture kit for Digital UP-D711 thermal printer
CrossXBeam Digital UP-D711 thermal printer
SRI-HD (High Definition Speckle Reduction Imaging) Digital UP-D25 Color thermal printer
B-Steer Digital UP-D897 BW thermal printer
Coded Phase Inversion Harmonic Imaging HP office jet 100 Mobile Printer
Virtual Convex 1-Peadl type footswitch ‘Whanam FSU-1000’
Patient information Database Footswitch MKF 2-MED USB GP26

2
GE Healthcare

LOGIQ F8
Version 1.0

SanDisk USB Stick 4G Ver Time line display


1TB mobile USB HDD • Independent Dual B/PW or CW Display
LITEON eUAU108 DVD RW Kit • Display Formats
USB Lamp – Top/Bottom selectable format (Size: 1/2:1/2; 1/3:2/3;
USB ECG Kits (AHA/IEC) 2/3:1/3)
– Side/Side selectable format (Size: 1/2:1/2; 1/4:3/4;
Display modes TL only)
Live and Stored Display Format: full size and Split screen Switchable after Freeze
– both with thumbnails for still and Cine • Timeline only
Review Image Format: 4x4 and “thumbnails” for still and • Virtual Convex
Cine • CrossXBeam
Simultaneous Capability • Tissue Velocity Imaging (TVI) Mode
 B/PW • Elastography and simultaneous B/Elasto
 B/CFM or PDI
 B/M Display annotation
 B + CFM/M Patient Name: First, Last (Max 28 characters displayed
 Real Time Triplex Mode (B + CFM or PDI/PW or CW) per each, Up to 64 total characters per each)
 Dual B (B/B) Patient ID (Max 54 characters)
Other ID (Max 54 characters)
Selectable alternating Modes Age, Sex and Date of Birth
• B/M Hospital Name (Max 23 characters displayed)
• B/PW Date format: 3 Types selectable
• B + CFM/M • MM/DD/YY
• B + CFM (PDI)/PW (CW) • DD/MM/YY
• 3D-Mode • YY/MM/DD
• 3D-Mode Color Time format: 2 types selectable
• B/CW • 24 hours
• B + CFM (PDI)/CW • 12 hours
• Multi-image split screen (quad screen) Gestational Age from
• Live and/or frozen • LMP • GA
• B + B/CFM or PDI • EDD • BBT
• PW/M Displayed Acoustic Output
• Independent CINE playback • TIS: Thermal Index Soft Tissue
Zoom: Write/Read/Pan • TIC: Thermal Index Cranial (Bone)
Colorized Image • TIB: Thermal Index Bone
 Colorized B • MI: Mechanical Index
 Colorized M % of Maximum Power output
 Colorized PW Probe Name
 Colorized CW Map Names
Probe Orientation

3
GE Healthcare

LOGIQ F8
Version 1.0

Depth Scale Marker Ver  Color Gain


Lateral Scale Marker  PDI
Focal Zone Markers  Inversion
Image Depth  Doppler Frequency
Zoom Depth TGC Curve
Cine Gage, Image Number/Frame Number
B-Mode Body Pattern: Multiple human
 Gain Application Name
 Dynamic Range Measurement Results
 Imaging Frequency Operator Message
 Edge Enhance Biopsy Guide Line and Zone
 Frame Averaging Heart Rate
 Frame Rate
 Gray Map General System Parameters
 ATO On/Off System Setup
 SRI-HD  8 Pre-programmable Categories
 CrossXBeam  User Programmable Preset Capability
M-Mode  Factory Default Preset Data
 Gain  Languages: English, Latin American Spanish, French,
 Dynamic Range German, Italian, Brazilian Portuguese, Chinese
 Time Scale (Simplified), Swedish, Russian, Norwegian, Danish,
Doppler Mode Dutch, Finnish, Japanese
 Gain  OB Report Formats including Tokyo Univ., Osaka
 Angle Univ., USA, Europe, and ASUM
 Sample Volume Depth and Width  User Defined Annotations
 Wall Filter  Body Patterns
 Velocity and/or Frequency Scale  Customized Comment Home Position
 Spectrum Inversion
 Time Scale CINE Memory/Image Memory
 PRF 128 MB of Cine Memory
 Doppler Frequency Selectable Cine Sequence for Cine Review
Color Flow Mode Prospective Cine Mark
 Line Density Measurements/Calculations and Annotations on Cine
 Frame Averaging Playback
 Packet Size Scrolling timeline memory
 Color Scale: 2 types Dual Image Cine Display
− Power Quad Image Cine Display
− Directional PDI Cine Gauge and Cine Image Number Display
 Color Velocity Range and Baseline Cine Review Loop
 Color Threshold Marker Cine Review Speed: 11 steps (11, 13, 14, 17, 22, 25, 31,

4
GE Healthcare

LOGIQ F8
Version 1.0

48, 100, 200, 400%) Ver Digital Agile Beamformer Architecture


193,536 System Processing Channels
Image Storage Max. Frame Rate: 710 F/s
On-board database of patient information Displayed Imaging Depth: 0 – 33 cm
Storage Formats: Minimum Depth of Field: 0 – 2 cm (Zoom) (probe
 DICOM – compressed/uncompressed, dependent)
single/multi-frame, with/without Raw Data Maximum Depth of Field: 0 – 33 cm (probe dependent)
 Export JPEG, JPEG2000, WMV (MPEG 4) and AVI Transmission Focus: 1 – 8 Focal Points selectable
formats (probe and application dependent)
DICOM Still Image Storage Size: ~2.1 MB Quad Beamforming
Display Format: Full Size, 4x4 and “thumbnails” Continuous Dynamic Receive Focus/Aperture
Storage Devices: Multi-Frequency/Wideband Technology
 Internal Hard Drive Partition of 220 GB for Image Frequency Range: 1.7 to 13 MHz
Storage 256 Shades of Gray
 External USB HDD and USB Memory Stick Support for 224dB Composite Dynamic Range
Import, Export, DICOM Read, SaveAs, and MPEGVue Adjustable Dynamic Range (36 - 96dB)
 CD-RW storage: 700 MB Adjustable Field of View (FOV): up to 128 degree
 DVD storage: -R (4.7 GB) (depending on probe)
Conversion to Formats: JPEG, AVI, WMV Image Reverse: Right/Left
Live Image and stored image side-by-side Display Image Rotation of 0,° 180°
Compare stored images with current exam
Reload of archived data sets B-Mode
Network Storage support for Import, Export, DICOM Acoustic Power Output: 0 – 100%, 2, 5, and 10 steps
Read, SaveAs, MPEGVue Gain: from 0 – 90 dB, 1 dB steps
Adjustable Dynamic Range: 36 – 96 dB, 3 or 6 dB steps
Connectivity & DICOM Frame Averaging: 8 steps
Ethernet network connection Gray Scale Map: 7 types
 DICOM 3.0 (Optional) Tint Map: 9 types
 Verify B Colorization: 10 types
 Print Frequency: Up to 11 selectable (depending on probe)
 Store Line Density: 5 steps
 Modality Worklist Line Density Zoom: 5 steps
 Storage Commitment Thermal Index: TIC, TIS, TIB
 Modality Performed Procedure Step (MPPS) Image Reverse: On/Off
 Query/Retrieve Focus Number: 8 steps
 Structured Reporting Template – which can be Focus Width: 3 types
compared to vascular and OB standard Suppression: 6 steps
 Remote capability InSite ExC Edge Enhance: 7 steps
Rejection: 6 steps
Scanning Parameters Steered Linear: ±15˚

5
GE Healthcare

LOGIQ F8
Version 1.0

Scanning Size (FOV or Angle – depending on the Ver


probe) • Spectrum Inversion
SRI-HD: Up to 6 Levels selectable • Duplex: Simultaneous: On/Off (PW only)
CrossXBeam: Up to 7 Angles selectable • PW Angle Steer: 0, ±10, 15, 20˚
Depth: 2 – 33 cm, 0.5 or 1 cm step, Probe dependent • Sample Volume Depth: 75 steps default pre-settable,
probe dependent
M-Mode • Trace Method: Off, Max, Mean
Gain: –20 -20 dB, 1 dB step • Baseline Shift: 11 steps
Dynamic Range: 36 to 96dB, 36~48/78~96 6dB step; • Doppler Auto Trace
48~78 3dB step. • Compression: 0.5~2.4(0.5,0.7,0.9,1,1.1,1.4,1.6,2,2.4)
Gray Scale Map: 7 types • Trace Direction: Above, Below, Both
B Colorization: 9 types • Trace Sensitivity: 0~40, 2 steps
Scanning Size (FOV or Angle – depending on probe, see
probe specifications) Color Flow Mode
Rejection: 6 steps Baseline: 0 – 100%, 10% steps
M/PW Display Format: V-1/3B, V-1/2B, V-2/3B, H-1/2B, Invert: On/Off
H-1/4B,Timeline only CF/PDI Focus Depth: default pre-settable for 10 – 100%
of ROI in depth, 10% or 16% step
Anatomical M-Mode (Option) CF/PDI Flash Suppression: 5 steps
M-Mode cursor adjustable at any plane CF/PDI Angle Steer: 0, ±10˚, ±15˚, ±20˚
Can be activated from a Cine loop from a live or stored Packet Size: 8 – 24, dependent on probe and Application
image Line Density: 5 steps
M and A capability Line Density Zoom: 5 steps
Available with Color Flow Mode Frame Average: 7 steps
PRF: 0.1 – 18.5 KHz/19 steps
Pulse Wave Doppler Mode Spatial Filter: 6 steps
• Acoustic Power: 0 – 100%, 2, 5, and 10 steps Gain: 0 – 40 dB, 0.5 dB steps
• Gain: 0 -85 dB, 1 dB step Wall Filter: 4 steps, dependent on probe and Application
• Gray Scale Map: Up to 8 types Scanning Size (FOV or Angle): Probe dependent
• PRF: 0.3 – 27.9 KHz CF/PDI Vertical Size (mm) of ROI: default pre-settable
• Transmit Frequency: 1.7~6.3MHz,probe depend CF/PDI Center Depth (mm) of ROI: default pre-settable
• Wall Filter: 5.5 – 5000Hz, 27 steps, dependent on CF/PDI Frequency: Up to 4, depending on probe
probe Color Maps, including velocity-variance maps: 14 types
• PW Colorization: Up to 6 types depending on Application
• Velocity Scale Range: 0.4 ~ 4084 cm/s Transparent: 5 steps
• Sweep Speed: 0~7, 8 steps Color Threshold: 0 – 100%, 10% steps
• Sample Volume Depth: 0.2~30 cm, probe depend Accumulation: 8 steps
• SV Gate: 1, 2, 3, 4, 5, 6, 7, 8, 10, 12, 14, 16 mm
• Angle Correction: -90~90, 1 steps Power Doppler Imaging
• M/PW Display Format: V-1/3B, V-1/2B, V-2/3B, H-1/2B, PDI Map: 14 types
H-1/4B, Timeline only CF/PDI Focus Depth: default pre-settable for 10 – 100%

6
GE Healthcare

LOGIQ F8
Version 1.0

of ROI in Depth, 10% or 15% step Ver Auto-Spectral Optimize adjusts


CF/PDI Acoustic Output: 0 – 100%, 2%, 5% or 10% step • Baseline
CF/PDI Angle Steer: 0, ±10˚, ±15˚, ±20˚ • Invert
Packet Size: 8 – 24, dependent on probe and application • PRF (on live image)
Spatial Filter: 6 steps • Angle correction
Frame Average: 7 steps
PRF: 0.1 – 18.5 KHz/19 steps Coded Harmonic Imaging
Power Threshold: 0 – 100%, 10% steps Coded Phase Inversion Harmonic Imaging
Gain: 0 – 40 dB, 0.5 dB steps Available on all Probes
Wall Filter: 4 steps depending on probe and application Line Density: 5 steps
CF/PDI Frequency: Up to 4 steps, depending on probe Line Density Zoom: 5 steps
Transparent: 5 steps Suppression: 6 steps
Invert: On/Off Edge Enhance: 7 steps
Accumulation: 8 steps Gray Scale Map: 7 types
Flash Suppression Tint Map: 9 types
Gain: 0 – 90 dB, 1 dB step
Continuous Wave Doppler (Option) Dynamic Range: 36 to 96dB, 36~48/78~96 6dB step;
Gray Scale Map: 8 types Rejection: 6 step
Baseline: 11 steps Frequency: Up to 4 steps, probe depended
Angle Correct: ±90˚, 1˚ step
Spectral Color: 6 types LOGIQView (Option)
Invert: On/Off Extended Field of View Imaging
Spectral Averaging: 5 steps Available on 4C-RS, L6-12-RS, 8C-RS, 3Sc-RS,
Gain: 0 – 85 dB, 1 dB steps E8C-RS, RAB2-6-RS probes
Wall Filter: 5.5 – 5000Hz, 27 steps, dependent on probe For use in B-Mode
and application CrossXBeam is available on linear probes
CW-Mode includes: Auto detection of scan direction
• Transmit Frequency Post-process zoom
• CW Colorization Rotation
• Velocity Scale Range: 6 ~ 6004cm/s Auto fit on monitor
• Spectrum Inversion Measurements in B-Mode
• Trace Method Up to 60cm scan length
• Doppler Auto Trace
• Trace Direction Easy 3D (Option)
• Trace Sensitivity Allows unlimited rotation and planar translations
3D reconstruction from Cine sweep
Auto Optimization
Optimize B-Mode image to improve contrast resolution Static 3D/ Realtime 4D (option)
Selectable amount of contrast resolution improvement Available on RAB2-6-RS probe
(low, medium, high) Acquisition Modes: Realtime 4D mode,

7
GE Healthcare

LOGIQ F8
Version 1.0

Static 3D mode Ver Q-Analysis: Multiple Time Motion trace display from
Visualization Modes: selected points in the myocardium
 3D Rendering (Diverse surface and intensity projection
modes) Virtual Convex
 Sectional Planes (3 Section planes perpendicular to Provides a convex field of view
each other) Compatible with CrossXBeam
Render Mode: Surface texture, Surface Smooth,max-, Available on linear and Sector transducers
min-,X-ray, Mix Mode of two render Modes
Display Format: SRI-HD
 Quad: A-/B-/C-Plane/3D High Definition Speckle Reduction Imaging Provides
 Dual: A-Plane/3D multiple levels of speckle reduction
 Single: 3D or A- or B- or C-Plane Compatible with Side by Side DualView Display
Curved 3point Render start Compatible with all linear, convex and sector transducers
3D Movie Compatible with B-Mode, 3D/4D imaging
Scalpel: 3D Cut tool
3D Rotation Cine CrossXBeam
3D Volume Review Provides 3, 5, 7 of spatial compounding
4D Volume Cine Live Side by Side DualView Display
Compatible with:
Scan Assistant • Color Mode
Factory Programs • PW
User defined programs • SRI-HD
Steps include image annotations, mode transitions, basic • Coded Harmonic Imaging
imaging controls and measurement initiation • Virtual Convex
Available on 4C-RS, L6-12-RS, E8C-RS, 8C-RS,
Scan Coach RAB2-6-RS
Modules showing basic scanning techniques
With graphic of probe position, anatomy and example Controls Available While “Live”
clinical image Write Zoom
B/M/CrossXBeam-Mode
Elastography (Option) Gain
Available on L6-12-RS TGC
Semi-Quantification Dynamic Range
Acoustic Output
TVI (Option) Transmission Focus Position
Myocardial Doppler Imaging with color overlay on tissue Transmission Focus Number
image Line Density Control
Available on the sector probes Sweep Speed for M-Mode
Tissue color overlay can be removed to show just the 2D Number of Angles for CrossXBeam
image, still retaining the tissue velocity information PW-Mode

8
GE Healthcare

LOGIQ F8
Version 1.0

Gain Ver Invert Spectral wave form


Dynamic Range Compression
Acoustic Output Rejection
Transmission Frequency Colorized Spectrum
PRF Display Format
Wall Filter Doppler Audio
Spectral Averaging Angle Correct
Sample Volume Gate Quick Angle Correct
• Length Auto Angle Correct
• Depth Overall Gain (loops and stills)
Velocity Scale Color Map
Color Flow Mode Transparency Map
CFM Gain Frame Averaging (loops only)
CFM Velocity Range Flash Suppression
Acoustic Output CFM Display Threshold
Wall Echo Filter Spectral Invert for Color/Doppler
Packet Size Anatomical M-Mode on Cine loop
Frame Rate Control
CFM Spatial Filter Measurements/Calculations
CFM Frame Averaging General B-Mode
Frequency/Velocity Base Line Shift Depth and Distance
Circumference (Ellipse/Trace)
Controls Available on “Freeze” or Recall Area (Ellipse/Trace)
Automatic Optimization Volume (Ellipsoid)
SRI-HD % Stenosis (Area or Diameter)
CrossXBeam – Display non-compounded and Angle between two lines
compounded
image simultaneously in split screen General M-Mode
3D reconstruction from a stored Cine loop M-Depth
B/M/CrossXBeam Mode Distance
Gray Map Optimization Time
TGC Slope
Colorized B and M Heart Rate
Frame Average (loops only)
Dynamic Range: Anatomical M-Mode General Doppler Measurements/Calculations
Sweep Speed Velocity
Gray Map Time
Post Gain A/B Ratio (Velocities/Frequency Ratio)
Baseline shift PS (Peak Systole)
Sweep Speed ED (End Diastole)

9
GE Healthcare

LOGIQ F8
Version 1.0

PS/ED (PS/ED Ratio) Ver • OFD (Occipital Frontal Diameter)


ED/PS (ED/PS Ratio) • TAD (Transverse Abdominal Diameter)
AT (Acceleration Time) • TCD (Transverse Cerebellum Diameter)
ACCEL (Acceleration) • THD (Thorax Transverse Diameter)
TAMAX (Time Averaged Maximum Velocity) • TIB (Tibia Length)
Volume Flow (TAMEAN and Vessel Area) • ULNA (Ulna Length)
Heart Rate Estimated Fetal Weight (EFW) by:
PI (Pulsatility Index) • AC, BPD
RI (Resistivity Index) • AC, BPD, FL, HC
• AC, FL, HC
Real-time Doppler Auto Measurements/Calculations • BPD, APTD, TTD, FL
PS (Peak Systole) Calculations and Ratios
ED (End Diastole) • FL/BPD
MD (Minimum Diastole) • FL/HC
PI (Pulsatility Index) • CI (Cephalic Index)
RI (Resistivity Index) • CTAR(Cardio-Thoracic Area Ratio)
AT (Acceleration Time) Measurements/Calculations by: ASUM, ASUM 2001,
ACC (Acceleration) Berkowitz,
PS/ED (PS/ED Ratio) Bertagnoli, Brenner, Campbell, CFEF, Chitty, Eik-Nes,
ED/PS (ED/PS Ratio) Ericksen,
HR (Heart Rate) Goldstein, Hadlock, Hansmann, Hellman, Hill, Hohler,
TAMAX (Time Averaged Maximum Velocity) Jeanty,
PVAL (Peak Velocity Value) JSUM, Kurtz, Mayden, Mercer, Merz, Moore, Nelson,
Volume Flow (TAMEAN and Vessel Area) Osaka
University, Paris, Rempen, Robinson, Shepard,
OB Measurements/Calculations Shepard/Warsoff,
Gestational Age by: Tokyo University, Tokyo/Shinozuka, Yarkoni
• GS (Gestational Sac) Fetal Graphical Trending
• CRL (Crown Rump Length) Growth Percentiles
• FL (Femur Length) Multi-Gestational Calculations (4)
• BPD (Biparietal Diameter) Fetal Qualitative Description (Anatomical survey)
• AC (Abdominal Circumference) Fetal Environmental Description (Biophysical profile)
• HC (Head Circumference) Programmable OB Tables
• APTD x TTD (Anterior/Posterior Trunk Diameter by Over 20 selectable OB Calculations
Transverse Expanded Worksheets
Trunk Diameter)
• FTA (Fetal Trunk Cross-sectional Area) GYN Measurements/Calculations
• HL (Humerus Length) Right Ovary Length, Width, Height
• BD (Binocular Distance) Left Ovary Length, Width, Height
• FT (Foot Length) Uterus Length, Width, Height

10
GE Healthcare

LOGIQ F8
Version 1.0

Cervix Length, Trace Ver measurements


Ovarian Volume Parameter annotation follow ASE standard
ENDO (Endometrial thickness)
Ovarian RI Probes
Uterine RI 4C-RS
Follicular measurements Convex Probe
Summary Reports  Applications: Abdomen, OB/Gyn, Vascular, Urology
 Number of Element: 128
Vascular Measurements/Calculations  Convex Radius: 60 mmR
SYS DCCA (Systolic Distal Common Carotid Artery)  FOV: 55°
DIAS DCCA (Diastolic Distal Common Carotid Artery)  Footprint: 18.3 x 66.2 mm
SYS MCCA (Systolic Mid Common Carotid Artery)  B-Mode Imaging Frequency
DIAS MCCA (Diastolic Mid Common Carotid Artery) 2.0, 3.0, 4.0, 5.0 MHz
SYS PCCA (Systolic Proximal Common Carotid Artery)  Harmonic Imaging Frequency:
DIAS PCCA (Diastolic Proximal Common Carotid Artery) 3.0, 4.0, 5.0 MHz
SYS DICA (Systolic Distal Internal Carotid Artery)  CFM/PDI/PWD Frequency: 2.0, 2.8, 3.6 MHz
DIAS DICA (Systolic Distal Internal Carotid Artery)  Biopsy Guide: Multi Angle, Reusable Bracket
SYS MICA (Systolic Mid Internal Carotid Artery)
DIAS MICA (Diastolic Mid Internal Carotid Artery) L6-12-RS
SYS PICA (Systolic Proximal Internal Carotid Artery) Linear Probe
DIAS PICA (Diastolic Proximal Internal Carotid Artery)  Applications Vascular, Small Parts, Pediatrics
SYS DECA (Systolic Distal External Carotid Artery)  Number of Element: 128
DIAS DECA (Diastolic Distal External Carotid Artery)  Footprint: 38.4 x 6.0 mm
SYS PECA (Systolic Proximal External Carotid Artery)  B-Mode Imaging Frequency:
DIAS PECA (Diastolic Proximal External Carotid Artery) 6.0, 8.0, 10.0, 11.0 MHz
VERT (Systolic Vertebral Velocity)  Harmonic Imaging Frequency:
SUBCLAV (Systolic Subclavian Velocity) 8.0, 10.0, 12.0, 13.0 MHz
Automatic IMT  CFM/PDI/PWD Frequency: 4.0, 5.0, 6.0 MHz
Summary Reports  Steered Angle : +/-
 Biopsy Guide: Multi Angle, Reusable Bracket
Urological Calculations
Bladder Volume E8C-RS
Prostate Volume Endo Micro Convex Probe
Lt/Rt Renal Volume  Applications: OB/Gyn, Urology, Transvaginal,
Generic Volume Transrectal
Post-Void Bladder Volume  Number of Element: 128
 Convex Radius: 10.73 mmR
Cardiac Measurements/Calculations  FOV: 128°
Cardiac calculation package including extensive  Footprint: 16.9 x 21.2 mm
measurements and display of multiple repeated  B-Mode Imaging Frequency: 6.0, 8.0, 10.0 MHz

11
GE Healthcare

LOGIQ F8
Version 1.0

 Harmonic Imaging Frequency: Ver  B-Mode Imaging Frequency: 3.0, 4.0, 5.0 MHz
7.0, 8.0, 10.0 MHz  Harmonic Imaging Frequency: 4.0, 6.0 MHz
 CFM/PDI/PWD Frequency: 4.2, 5.0, 6.3 MHz  CFM/PDI/PWD Frequency: 2.0, 3.0, 4.0 MHz
 Biopsy Guide: Fixed Angle,  Biopsy Guide: Multi Angle, Reusable Bracket
Disposable, or Reusable Bracket
Inputs and Outputs
8C-RS CVBS output (BNC)
Micro Convex Probe S-Video output
 Applications: Pediatrics VGA output (SXGA resolution)
 Number of Element: 128 Audio stereo output
 Convex Radius: 10.73 mmR 100BASE-TX Ethernet (RJ45)
 FOV: 128° USB (3x in rear, 3 under keyboard)
 Footprint: 12.0 x 22.0mm
 B-Mode Imaging Frequency: 6.0, 8.0, 10.0 MHz Safety Conformance
 Harmonic Imaging Frequency: The LOGIQ F8 is:
7.0, 8.0, 10.0 MHz CE Marked to Council Directive 93/42/EEC on Medical
 CFM/PDI/PWD Frequency: 4.2, 5.0, 6.3 MHz Devices
 Biopsy Guide: Not Available Conforms to the following standards for safety:
• IEC 60601-1 Medical electrical equipment—Part 1:
3Sc-RS General
Phased Array Sector Probe requirements for safety
 Applications: Cardiac, Transcranial • IEC 60601-1-2 Medial electrical equipment—Part 1-2
 Number of Element: 64 General
 FOV: 90° requirements for safety—Collateral Standard:
 Footprint: 27.6 x 19.3 mm Electromagnetic
 B-Mode Imaging Frequency: 2.0, 3.0, 4.0 MHz compatibility—requirements and tests EMC Emissions
 Harmonic Imaging Frequency: Group 1
3.0, 3.2, 3.5, 4.0 MHz Class A device requirements as per CISPR 11
 CFM/PDI/PWD Frequency: 1.7, 2.0, 2.5, 3.3 MHz • IEC 60601-2-37 Medical electrical equipment—Part
 CWD Frequency: 1.9 MHz 2-37: Particular
 Biopsy Guide: Multi Angle, Reusable Bracket requirements for the safety of ultrasonic medical
diagnostic and
RAB2-6-RS monitoring equipment
Convex Volume Probe • ISO 10993-1 Biological evaluation of
 Applications: Abdomen, OB/GYN, Urology medical devices—Part 1 Evaluation and testing
 Number of Element: 128 • EN 62366 Medical devices —Application of usability
 Convex Radius : 47 mmR engineering
 Footprint: 62.2 x 34.0 mm to medical devices
 Volume Sweep Radius: 26.81 mm
 FOV: 55° (B), 84° x 55° (Volume scan)

12
GE Healthcare

LOGIQ F8
Version 1.0

Ver
About GE Healthcare
GE Healthcare provides transformational medical
technologies and services to meet the demand for
increased access, enhanced quality and more affordable
healthcare around the world. GE (NYSE: GE) works on
things that matter - great people and technologies taking
on tough challenges. From medical imaging, software &
IT, patient monitoring and diagnostics to drug discovery,
biopharmaceutical manufacturing technologies and
performance improvement solutions, GE Healthcare
helps medical professionals deliver great healthcare to
their patients.

GE Healthcare
Pollards Wood, Nightingales Ln
Chalfont St Giles
Buckinghamshire HP8 4SP
United Kingdom
Phone:+44 1494 544000
www.gehealthcare.com

.2013 General Electric Company — All rights reserved.

General Electric Company reserves the right to make changes in specifications and

features shown herein, or discontinue the product described at any time without notice

or obligation. Contact your GE Representative for the most current information.

GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC,

a General Electric company, doing business as GE Healthcare.

GE, the GE Monogram, and imagination at work

are trademarks of General Electric Company.

*Trademark of General Electric Company.

DICOM is the registered trademark of the National Electrical Manufacturers Association

for its standard publications relating to digital communications of medical information.

GE Healthcare, a division of General Electric Company.

13