0% found this document useful (0 votes)
191 views1 page

CMM Roundness

This document is a calibration report from Carl Zeiss dated January 1, 2004. It summarizes the measurement of roundness on a part using a CMM machine. Key details include measuring roundness of a feature called "Roundness1" with an actual measurement of 0.0101 and tolerance of 0.1000.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
191 views1 page

CMM Roundness

This document is a calibration report from Carl Zeiss dated January 1, 2004. It summarizes the measurement of roundness on a part using a CMM machine. Key details include measuring roundness of a feature called "Roundness1" with an actual measurement of 0.0101 and tolerance of 0.1000.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Date January 1,

Calypso

5.4.20
Carl Zeiss 2004 Order * order *

Department:
Part Number CMM Drawing No.
CONT_ Operator Master
* drawingno * Signature:
1 G2
Measurement Plan
Measurement Plan Roundness1
25

Circle3("Roundness1")

50.0
um

Magnification 200.0
No Identifier Actual Tol. D-Act D-Nom Number of Points
Speed Stylus uFs.Typ L-C UP
Radi R

1 Roundness1 0.0101 0.1000 19.986 19.985 38 3 1.5011


1 0 14 30 6