1. INTRODUCTION
CNC-200A is a series of COIL WINDING MACHINE CONTROLLER developed by MINSU
AUTOMATION. It not only retains all the features of previous designs, it also has a low noise
level and is less sensitive to external power fluctuation.
CNC-200A also features an integrated design: putting stepper motor driver, DC motor speed
controller, brake and power supplier control circuits into one control box, simultaneously
achieving size reduction, high performance and low cost.
2. MAIN FEATURES
◆ Single chip Microprocessor design, has further higher performance and higher
functions; it also has less sensitive to external power fluctuation or to external
electromagnetic interference.
◆ Memory use FLASH ROM, capacity capable storing up to 1000 steps winding data,
9 winding parameters, and 5 options can be independently assigned for each step.
Off-power memory retention without battery.
◆ Winding speed can be specified using the front panel keypad, resulting in easy
programming of multi-step, multi-speed settings.
◆ Guiding traverse shaft stepper motor with a constant-current driver offering fast
wire guiding speeds.
◆ Guiding traverse shaft offering 10 steps moving speed selection.
◆ Software can be update through the personal computer.
◆ Power input AC100V~120V、220V~240V 600VA(max).
READY
RUN
MOVE
Q.S.
SHIFT
WIDTH
TURNS
S.SLOW
H.S.
L.S.
MINSU AUTO CNC-200A
POWER
FEED
DIR
END
STEP 4 5 6 QTY
SET
STEP RPM QTY FINISH
WIND
DIR
AUTO
HOME 1 2 3 ―
RPM ZERO EDGE
STOP
AUTO
START 0 CLR COPY ENT
PREV
AUTO BRAKE NEXT RESET STOP START
IOUS
Page 2 of 14
█ CNC-200A USER MANUAL VER. H8681/3
STEP DISPLAY:Show the current step number being wound or being programmed.
DATA DISPLAY:During programming, in combination with LED, shows the parameter being
programmed. During winding or ready mode, show the current number of turns or show the
guiding traverse shafts position.
Page 3 of 14
█ CNC-200A USER MANUAL VER. H8681/3
Page 4 of 14
█ CNC-200A USER MANUAL VER. H8681/3
Page 5 of 14
█ CNC-200A USER MANUAL VER. H8681/3
Page 6 of 14
█ CNC-200A USER MANUAL VER. H8681/3
◆ Edges slow mode
The winding speed will slow down before the guiding traverse reach to the two edges of
the width (work with『E. SLOW』turns). After the guiding traverse veered, then restore to
hi-speed winding. (Refer to the section 7.1. edge slow mode).
◆ Automatically circularly mode
If key set to on, it means Automatically circularly mode, in this mode when finish a
step of winding it will automatically get into next step and start winding without press
key (work with and keys).
Page 7 of 14
█ CNC-200A USER MANUAL VER. H8681/3
6. WINDING EXECUTION
6.1. To start winding
After set up all data items, press key, the winding process begins in accordance with the
set-up content. Press key to pause winding. During winding, press the key, the winding
speed can be switch between high speed and low speed.
The following key functions are available during PAUSE mode:
: Give up the numbers of the winding turns and regress one step.
: Finish current step and proceed to next step.
: Continue winding.
: Give up winding and go back to the READY mode.
Page 8 of 14
█ CNC-200A USER MANUAL VER. H8681/3
7. CONFIGURATION SETTING
CNC-200A is a multi-purpose design, to meet various requirements; additional settings are
configured to provide flexibility for additional applications.
In the READY mode, press the following keys combination as section [7.1. ~7.10], the DATA
DISPLAY will show corresponding setting value. If no change is necessary, press the key
get back to READY mode. Or press key to get into change mode, then the parameter can
be changed by pressing the numerical key followed by the key.
7.1. Winding mode selection Initial value[10010100]
In this function the STEP display and the DATA display will shows eight digits, representing
eight winding mode selections respectively.Press numerical keys as below to set each digit.
8 7 6 5 4 3 2 1
NO Function
Control Mode:Select control mode of winding spindle driver.
0 represents CW=Forward/Stop, CCW=Reverse/Stop.
1 represents RUN=Motion/stop, DIR=Forward/Reverse,
Counting mode:Select the counting mode of the winding spindle shaft.
0 represents with zero point and using absolute counting mode.
1 represents without zero point and using relative counting mode.
2 represents with zero point and using relative counting mode.
3 represents without zero point and using absolute counting mode.
Edge slow:Slow down the winding speed before the guiding traverse reach to the two
edges of the width.
0 represents not slow down; 1 represents to slow down.
Braking mode:Select the braking mode of the winding spindle.
0 represents single brake mode; 1 represents double brake mode.
Counting unit:Select 0.1 or 1 turns as your count unit.
0 represents 0.1(0.0 to 9999.9 turns); 1 represents 1(0 to 99999 turns).
Guiding traverse unit:Select the basic unit of guiding traverse.
0 represents mm; 1 represents inch (must using lead screw in imperial).
Operation mode:Select operation mode for the START switch.
0 represents ON-OFF mode; 1 represents Trigger mode.
The key on the front panel always as the Trigger mode.
7.2. Station number Initial value[0]
[Setting range 01~99].
Page 9 of 14
█ CNC-200A USER MANUAL VER. H8681/3
Page 10 of 14
█ CNC-200A USER MANUAL VER. H8681/3
+24V
+24V
+24V
+24V
PUS
DIR
LAMP 1
LAMP 2
LAMP 3
RESET
HOME
PHA
PHB
PHC
CN7
IP 5
IP 6
IP 4
IP 3
IP 2
IP 1
STOP
START
OV
COM
COM
COM
OP 4
OP 3
OP 2
OP 1
TR +
TR -
Pulse Output RS-485 Operate Switches Home Sensor Turn Counter AUX I/O
CN7 CN2 CN3 CN4 CN5 CN6
COM
IP4
IP3
+ 24
IP2
IP1 OP1
OP2
IP5 OP3
IP6 OP4
1
2
AUX I/O
a b a b a b
3 4 3 4 3 4
1 2 1 2 1 2 1 1
Page 11 of 14
█ CNC-200A USER MANUAL VER. H8681/3
◆ Drive STEP Motor in directly
+5V
+24V
+24V
+24V
+24V
PUS
DIR
LAMP 1
LAMP 2
LAMP 3
RESET
HOME
PHA
PHB
PHC
CN7
IP 5
IP 6
IP 4
IP 3
IP 2
IP 1
STOP
START
OV
COM
COM
COM
OP 4
OP 3
OP 2
OP 1
TR +
TR-
Pulse Output RS-485 Operate Switches Home Sensor Turn Counter AUX I/O
CN7 CN2 CN3 CN4 CN5 CN6
GND
AC
AC
CN8 - -
AC AC RUN F/R H/L BK+ BK- A A B B
1 2 3 4 5 6 7 8 9 10 11 12
AC Output
GND
CN8
GND
AC
AC
COM
CW
CCW
H/L
Vin
Motor Driver
AC
AC
-
A A
B
M -
B
2Phase 6V 2A
AC Output EARTH AC Input Winding Spindle DC24V 12W
Guiding Traverse
(MAX 400W) Motor
STEP Motor
+24V
+24V
+24V
+24V
PUS
DIR
LAMP 1
LAMP 2
LAMP 3
RESET
HOME
PHA
PHB
PHC
CN7
IP 5
IP 6
IP 4
IP 3
IP 2
IP 1
STOP
START
OV
COM
COM
COM
OP 4
OP 3
OP 2
OP 1
TR +
TR-
Pulse Output RS-485 Operate Switches Home Sensor Turn Counter AUX I/O
CN7 CN2 CN3 CN4 CN5 CN6
AC
CN8 - -
AC AC RUN F/R H/L BK+ BK- A A B B
1 2 3 4 5 6 7 8 9 10 11 12
AC Output
GND
CN7
CN8
GND
AC
AC
PUS
DIR
H/L
COM
CW
CCW
Vin
V+
DC-
AC
AC
-
A A
B
-
M
B
2Phase STEP Motor AC Output EARTH AC Input Winding Spindle DC24V 12W
Guiding Traverse (MAX 400W) Motor Brake
Page 12 of 14
█ CNC-200A USER MANUAL VER. H8681/3
9.4. Troubleshooting
This section provides information to guide the user in understanding different fault condition
and their general troubleshooting procedures, and with their possible solutions.
◆ Do not connect or disconnect wires and connectors while power is applied to the
controller.
◆ Make sure that the leads and connectors are connected correctly, before doing the
troubleshooting procedures.
◆ Do not remove welded parts on the PC board without appropriate tools.
Page 13 of 14
█ CNC-200A USER MANUAL VER. H8681/3
2 Power ON, but the display a. Replace 200A-CPU.
shows confusion massage
3 Power ON, but winding a. Press o make the controller get into READY
spindle didn’t rotate, or mode.
cannot stop rotation, And
b. Check the winding parameter『L.S.』setting value of
controller cannot get into
START STEP
ready mode.
c. Replace turns counter CNTB-03B.
d. Replace 200A-CPU.
4 Power ON, but guiding a. Press to make the controller get into READY
traverse didn’t move or mode.
cannot stop moving, And
b. Replace HOME SENSOR.
controller cannot get into
c. Replace 200A-DVR.
ready mode.
d. Replace 200A-CPU.
5 Cannot edit parameters. a. Check the READY LED lamp if not lit, do
procedures number 3 and 4.
b. Key in four numbers password before edit, if the
password has been set before.
c. Replace 200-KBD.
d. Replace 200A-CPU.
6 Display shows Err-0, then a. Replace 200A-CPU.
reset, and get into READY
mode.
7 Display shows Err-1/Err-2 a. Check winding parameters『SHIFT』and『WIDTH』
then reset and get into setting value.
READY mode.
b. Check configurations 『TRAVEL LIMIT』setting
value.
8 Display shows Err-3, a. Check winding parameters『SHIFT』and『WIDTH』
then reset, and get into setting value.
READY mode.
b. Replace HOME SENSOR.
9 Brake failure. a. Check wire connections of brake.
b. Replace brake.
c. Replace 200A-DVR.
10 Winding spindle can a. Check configurations 『Winding spindle control
not switching winding mode selection 』setting value.
direction.
b. Replace 200A-CPU.
Page 14 of 14