1. The document describes a valve (VLV-100) with its connections, parameters, sizing conditions, and stream properties for an inlet and outlet stream. 2. Key specifications of the valve include a pressure drop of 280 kPa, 50% valve opening, ANSI/ISA sizing method, and a sized coefficient of 5.168e+004. 3. The inlet stream has a temperature of 143.6°C and pressure of 1200 kPa, while the outlet stream has a temperature of 140.4°C and pressure of 920 kPa.

Uploaded by

Schaiera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views3 pages

Lab 2 (I) 2

1. The document describes a valve (VLV-100) with its connections, parameters, sizing conditions, and stream properties for an inlet and outlet stream. 2. Key specifications of the valve include a pressure drop of 280 kPa, 50% valve opening, ANSI/ISA sizing method, and a sized coefficient of 5.168e+004. 3. The inlet stream has a temperature of 143.6°C and pressure of 1200 kPa, while the outlet stream has a temperature of 140.4°C and pressure of 920 kPa.

Uploaded by

Schaiera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

1

Case Name: LAB 2 (i).hsc


2 Company Name Not Available
3 Bedford, MA Unit Set: SI
4 USA
Date/Time: Thu Oct 3 22:15:42 2019
5
6
7 Valve: VLV-100
8
9
CONNECTIONS
10
11
Inlet Stream
12
13 STREAM NAME FROM UNIT OPERATION

14 1
15
Outlet Stream
16
17 STREAM NAME TO UNIT OPERATION

18 2 Cooler E-100

19
PARAMETERS
20
21
Physical Properties
22
23 Pressure Drop: 280.0 kPa

24
User Variables
25
26
RATING
27
28
Sizing
29
30 Sizing Conditions

31 Inlet Pressure 1200 kPa * Molecular Weight 17.23 Current

32 Valve Opening 50.00 % * Delta P 280.0 kPa Flow Rate 7.814e+004 kg/h

33 Valve Sizing Method and Type

34 Sizing Method: ANSI/ISA

35 Valve Operating Characteristic and Sizing Information

36 Linear Sized Coefficient: Cg

37 Fl 0.9000 Cv 1544 USGPM(60F,1psi) Cg 5.168e+004 Fp 1.000 Xt 0.7000 Rigorous Cp/Cv Method

38
Nozzle Parameters
39
40 Base Elevation Relative to Ground Level 0.0000 m *
41 1 2

42 Diameter (m) 5.000e-002 5.000e-002

43 Elevation (Base) (m) 0.0000 0.0000

44 Elevation (Ground) (m) 0.0000 0.0000

45 Elevation (% of Height) (%)

46
CONDITIONS
47
48 Name 1 2

49 Vapour 1.0000 1.0000

50 Temperature (C) 143.6000 * 140.4051

51 Pressure (kPa) 1200.0000 * 920.0000 *


52 Molar Flow (kgmole/h) 4536.0000 * 4536.0000

53 Mass Flow (kg/h) 78141.7656 78141.7656

54 Std Ideal Liq Vol Flow (m3/h) 116.6871 116.6871

55 Molar Enthalpy (kJ/kgmole) -8.112e+004 -8.112e+004

56 Molar Entropy (kJ/kgmole-C) 166.2 168.3

57 Heat Flow (kJ/h) -3.6795e+08 -3.6795e+08

58
PROPERTIES
59
60 Name 1 2

61 Molecular Weight 17.23 17.23

62 Molar Density (kgmole/m3) 0.3647 0.2785

63 Mass Density (kg/m3) 6.283 4.798

64 Act. Volume Flow (m3/h) 1.244e+004 1.629e+004

65 Mass Enthalpy (kJ/kg) -4709 -4709

66 Mass Entropy (kJ/kg-C) 9.648 9.770

67 Heat Capacity (kJ/kgmole-C) 40.16 39.55

68 Mass Heat Capacity (kJ/kg-C) 2.331 2.296

69 Aspen Technology Inc. Aspen HYSYS Version 11 Page 1 of 3


Licensed to: Company Name Not Available * Specified by user.
1
Case Name: LAB 2 (i).hsc
2 Company Name Not Available
3 Bedford, MA Unit Set: SI
4 USA
Date/Time: Thu Oct 3 22:15:42 2019
5
6
7 Valve: VLV-100 (continued)
8
9
PROPERTIES
10
11 Name 1 2

12 LHV Molar Basis (Std) (kJ/kgmole) 2.535e+005 2.535e+005

13 HHV Molar Basis (Std) (kJ/kgmole) 3.109e+005 3.109e+005

14 HHV Mass Basis (Std) (kJ/kg) 1.805e+004 1.805e+004

15 CO2 Loading --- ---

16 CO2 Apparent Mole Conc. (kgmole/m3) --- ---

17 CO2 Apparent Wt. Conc. (kgmol/kg) --- ---

18 LHV Mass Basis (Std) (kJ/kg) 1.471e+004 1.471e+004

19 Phase Fraction [Vol. Basis] 1.000 1.000

20 Phase Fraction [Mass Basis] 1.000 1.000

21 Phase Fraction [Act. Vol. Basis] 1.000 1.000

22 Mass Exergy (kJ/kg) 426.2 389.7

23 Partial Pressure of CO2 (kPa) 0.0000 0.0000

24 Cost Based on Flow (Cost/s) 0.0000 0.0000

25 Act. Gas Flow (ACT_m3/h) 1.244e+004 1.629e+004

26 Avg. Liq. Density (kgmole/m3) 38.87 38.87

27 Specific Heat (kJ/kgmole-C) 40.16 39.55

28 Std. Gas Flow (STD_m3/h) 1.073e+005 1.073e+005

29 Std. Ideal Liq. Mass Density (kg/m3) 669.7 669.7

30 Act. Liq. Flow (m3/s) --- ---

31 Z Factor 0.9496 0.9607

32 Watson K 12.24 12.24

33 User Property --- ---

34 Partial Pressure of H2S (kPa) 0.0000 0.0000

35 Cp/(Cp - R) 1.261 1.266

36 Cp/Cv 1.340 1.326

37 Ideal Gas Cp/Cv 1.280 1.281

38 Ideal Gas Cp (kJ/kgmole-C) 37.99 37.91

39 Mass Ideal Gas Cp (kJ/kg-C) 2.205 2.200

40 Heat of Vap. (kJ/kgmole) 2.981e+004 3.035e+004

41 Kinematic Viscosity (cSt) 1.891 2.445

42 Liq. Mass Density (Std. Cond) (kg/m3) 678.0 678.0

43 Liq. Vol. Flow (Std. Cond) (m3/h) 115.3 115.3

44 Liquid Fraction 0.0000 0.0000

45 Molar Volume (m3/kgmole) 2.742 3.591

46 Mass Heat of Vap. (kJ/kg) 1730 1762

47 Phase Fraction [Molar Basis] 1.0000 1.0000

48 Surface Tension (dyne/cm) --- ---

49 Thermal Conductivity (W/m-K) 4.020e-002 3.945e-002

50 Bubble Point Pressure (kPa) 9675 9238

51 Viscosity (cP) 1.188e-002 1.173e-002

52 Cv (Semi-Ideal) (kJ/kgmole-C) 31.84 31.23

53 Mass Cv (Semi-Ideal) (kJ/kg-C) 1.848 1.813

54 Cv (kJ/kgmole-C) 29.97 29.82

55 Mass Cv (kJ/kg-C) 1.740 1.731

56 Cv (Ent. Method) (kJ/kgmole-C) --- ---

57 Mass Cv (Ent. Method) (kJ/kg-C) --- ---

58 Cp/Cv (Ent. Method) --- ---

59 Reid VP at 37.8 C (kPa) 1451 1451

60 True VP at 37.8 C (kPa) 1114 1114

61 Liq. Vol. Flow - Sum(Std. Cond) (m3/h) 115.3 115.3

62 Viscosity Index --- ---

63
DYNAMICS
64
65
Dynamic Specifications
66
67 Total Delta P (kPa) 280.0 Not Active

68 Pressure Flow Relation Active

69 Aspen Technology Inc. Aspen HYSYS Version 11 Page 2 of 3


Licensed to: Company Name Not Available * Specified by user.
1
Case Name: LAB 2 (i).hsc
2 Company Name Not Available
3 Bedford, MA Unit Set: SI
4 USA
Date/Time: Thu Oct 3 22:15:42 2019
5
6
7 Valve: VLV-100 (continued)
8
9
Dynamic Parameters
10
11 Valve Opening (%) 50.00 * Mass Flow (kg/h) 7.814e+004

12 Conductance (USGPM(60F,1psi)) 1544 Friction Delta P (kPa) 280.0

13
Malfunction Details
14
15 Actuator Failure Not Active Delay Time --- Ramp Time --- Fail Position Hold Specified OP ---

16 Valve Plugging Not Active Delay Time --- Ramp Time --- Valve Coeff. Decrease ---

17 Valve Leakage Not Active Delay Time --- Leakage Opening ---

18 Valve Deadtime Not Active Delay Time --- Valve Deadtime 0.0000 seconds *
19 Valve Additional Offset Not Active Delay Time --- Additional Offset ---

20 Valve Stickiness Not Active Delay Time --- Valve Stickiness Time Constant ---

21
Pipe Model Parameters
22
23 Material Cast Iron Darcy Friction Factor ---

24 Roughness (m) 2.590e-004 Pipe k (kg/hr/sqrt(kPa-kg/m3)) 0.0000

25 Pipe Length (m) 0.0000 * Velocity (m/s) 1760 *


26 Feed Diameter (m) 5.000e-002 Reynolds Number 4.653e+007 *
27
Hold-Up Volume: 0.0000 m3 *
28
29 Phase Accumulation Moles Volume

30 (kgmole/h) (kgmole) (m3)

31 Vapour 0.0000 0.0000 0.0000

32 Liquid 0.0000 0.0000 0.0000

33 Aqueous 0.0000 0.0000 0.0000

34 Total 0.0000 0.0000 0.0000


35
Actuator Parameters
36
37
Actuator Mode: Instantaneous
38
39 Actuator First-order Time Constant (seconds) 1.000 * Actuator Linear Rate 1.000 *
40 Valve Stickiness Time Constant (seconds) --- Actuator Second-order Time Constant (seconds) 1.000 *
41 Actuator Second-order Damping Factor 1.000 *
42
Actuator Position
43
44
Signal Fail Position: None
45
46 Min Max Current Desired Offset
47 (%) (%) (%) (%) (%)

48 Valve 0.00 * 100.00 * 50.00 * --- 0.00 *


49 Actuator 0.00 * 100.00 * 50.00 * 50.00 * ---

50