30kW Capstone Microturbine

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

C30 Microturbine

High-pressure Natural Gas

Achieve ultra-low emissions and reliable electrical


generation from natural gas.
Ultra-low emissions
One moving part – minimal maintenance and downtime
Patented air bearings – no lubricating oil or coolant
Integrated utility synchronization – no external switchgear(1)
Compact modular design allows for easy, low-cost installation
Multiple units easily combined – act as single generating source
Remote monitoring and diagnostic capabilities
Proven technology with tens of millions of operating hours
Various Factory Protection Plans available
C30 Microturbine

Electrical Performance(2)

Electrical Power Output 30 kW


Voltage 400 /480 VAC
Electrical Service 3-Phase, 4 Wire Wye
Frequency 50/60 Hz
Electrical Efficiency LHV 26%

Fuel/Engine Characteristics(2)

Natural Gas HHV 30.7– 47.5 MJ/m3 (825 –1,275 BTU/scf)


Inlet Pressure 379– 413 kPa gauge (55 – 60 psig)
Fuel Flow HHV 457 MJ/hr (433,000 BTU/hr)
Net Heat Rate LHV 13.8 MJ/kWh (13,100 BTU/kWh)

Exhaust Characteristics(2)

NOx Emissions @ 15% O2 < 9 ppmvd (18 mg/m3)


Exhaust Mass Flow 0.31 kg/s (0.69 lbm/s)
Exhaust Gas Temperature 275°C (530°F)

Dimensions & Weight(3)

Width x Depth x Height(4) 0.76 x 1.52 x 1.79 m (30 x 60 x 71 in)


Weight - Grid Connect Model 405 kg (891 lb)
Weight - Dual Mode Model 578 kg (1,271 lb)

Reliable power when and where you need it. Clean and simple.
Minimum Clearance Requirements(5)

Horizontal Clearance
Left & Right 0.76 m (30 in)
Front 0.93 m (37 in)
Rear 0.90 m (35 in)

Acoustic Emissions

Nominal at Full Power at 10 m (33 ft) 65 dBA

Certifications

• UL 2200 Listed
• CE Certified

C30 Engine Components

Exhaust Outlet Recuperator

Compressor
Generator Fuel Injector

Combustion Chamber
Air Bearings

Turbine Recuperator Housing

(1) Some utilities may require additional equipment for grid interconnectivity
(2) Nominal full power performance at ISO conditions: 15˚C (59˚F), 14.696 psia, 60% RH
(3) Approximate dimensions and weights
(4) Height dimensions are to the roofline. Exhaust stack extends approximately 170 mm (7 in) above the roofline
(5) Clearance requirements may increase due to local code considerations
Specifications are not warranted and are subject to change without notice.

©2019 Capstone Turbine Corporation. P0819 C30 HP Natural Gas Data Sheet CAP135 | Capstone P/N 331140A
Call us (toll free) 1.866.422.7786 | Tel: 1.818.734.5300 | www.capstoneturbine.com
www.capstoneturbine.com

You might also like