Staircase: Charateristic

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 5

STAIRCASE

Charateristic Moment & Shear about Y-Y axis , Long Span


Thickness = 165 mm Ultimate moment = 797.12
Thread = 260 mm Width = 1000
Riser = 178 mm Effective depth , d = 109
No of Step = 14 k = 0.0405
Slope = 34.3 Degree z = 563
Cos Slope = 0.84 Asreq = 3539
Asprov = 3927
Finishes = 1 kPA = H25-125mm c/c
Landing Length = 1000 mm
Step Length = 3640 mm Shear checking
Total = 4640 mm Ultimate shear = 343.58
Shear stress , v = 3.15
Dead Load Concrete shear stress , vc = 0.18
Step = 7.78 kN/m av = 175
Waist = 26.45 kN/m 2d/av = 6.77
Total = 34.23 kN/m Width with enhancem = 500
Width without enhan = 0
Live Load Shear capacity , V = 370.7
Load = 4 kPA
Total = 18.56 kN/m SHEAR CHECK SATISFACTORY

Total Dead +Live = 74.05 kN/m Moment & Shear about X-X axis , Short Span
Design Load = 343.58 kN
Asmin = 1148 mm2
Asprov = 1149 mm2
= H16-175mm c/c
s , Long Span Deflection
kNm Percentage of required tension reinforcement
mm p = Asreq/bd
mm = 0.008453

Reference reinforcement ratio,


mm2 po = ((fck)^0.5)(10^-3)
mm2 = 0.005
H25-125mm c/c
Percentage of req. compression reinforcement
p'= As'req/bd
kN = 0
N/mm2
N/mm2 po < p
mm l/d = K[11 + 1.5(fck^0.5)(po/p) + 3.2(fck^0.5)(((po/p)-1)^1.5)]
k= 1.3
mm l/d = 20.48
mm
kN Modification Factor
Span less than 7 m 1

Steel area provided (Asp/Asreq)


s , Short Span = 4.64 < 1.5
= 1.5

l/d(allowable) = 30.73

l/d(actual) = 29.12 < l/d(allowable)

DEFLECTION CHECK SATISFACTORY


STAIRCASE

Charateristic Moment & Shear about Y-Y axis , Long Span


Thickness = 165 mm Ultimate moment = 239.18
Thread = 260 mm Width = 1000
Riser = 178 mm Effective depth , d = 109
No of Step = 8 k = 0.0405
Slope = 34.3 Degree z = 563
Cos Slope = 0.84 Asreq = 1062
Asprov = 1131
Finishes = 1 kPA = H12-100mm c/c
Landing Length = 1060 mm
Step Length = 2080 mm Shear checking
Total = 3140 mm Ultimate shear = 152.34
Shear stress , v = 1.40
Dead Load Concrete shear stress , vc = 0.16
Step = 4.44 kN/m av = 175
Waist = 17.54 kN/m 2d/av = 6.77
Total = 21.98 kN/m Width with enhancem = 500
Width without enhan = 0
Live Load Shear capacity , V = 322.0
Load = 4 kPA
Total = 12.56 kN/m SHEAR CHECK SATISFACTORY

Total Dead +Live = 48.52 kN/m Moment & Shear about X-X axis , Short Span
Design Load = 152.34 kN
Asmin = 777 mm2
Asprov = 785 mm2
= H10-100mm c/c

Provide similar reinforcement for other Staircase Section


s , Long Span Deflection
kNm Percentage of required tension reinforcement
mm p = Asreq/bd
mm = 0.004439

Reference reinforcement ratio,


mm2 po = ((fck)^0.5)(10^-3)
mm2 = 0.005
H12-100mm c/c
Percentage of req. compression reinforcement
p'= As'req/bd
kN = 0
N/mm2
N/mm2 po > p
mm l/d = K[11 + 1.5(fck^0.5)(po/p) + 3.2(fck^0.5)(((po/p)-1)^1.5)]
k= 1.3
mm l/d = 26.22
mm
kN Modification Factor
Span less than 7 m 1

Steel area provided (Asp/Asreq)


s , Short Span = 3.14 < 1.5
= 1.5

l/d(allowable) = 39.33

l/d(actual) = 18.08696 < l/d(allowable)


er Staircase Section
DEFLECTION CHECK SATISFACTORY
0 262 H10-300mm c/c
262 314 H10-250mm c/c
314 377 H12-300mm c/c
377 393 H10-200mm c/c
393 449 H10-175mm c/c
449 452 H12-250mm c/c
452 524 H10-150mm c/c
524 565 H12-200mm c/c
565 628 H10-125mm c/c
628 646 H12-175mm c/c
646 670 H16-300mm c/c
670 754 H12-150mm c/c
754 785 H10-100mm c/c
785 804 H16-250mm c/c
804 905 H12-125mm c/c
905 1005 H16-200mm c/c
1005 1047 H20-300mm c/c
1047 1131 H12-100mm c/c
1131 1149 H16-175mm c/c
1149 1257 H20-250mm c/c
1257 1340 H16-150mm c/c
1340 1571 H20-200mm c/c
1571 1636 H25-300mm c/c
1636 1608 H16-125mm c/c
1608 1795 H10-175mm c/c
1795 1963 H20-250mm c/c
1963 2011 H16-100mm c/c
2011 2094 H20-150mm c/c
2094 2454 H25-200mm c/c
2454 2513 H20-125mm c/c
2513 2805 H25-175mm c/c
2805 3142 H20-100mm c/c
3142 3272 H25-150mm c/c
3272 3927 H25-125mm c/c
3927 4909 H25-100mm c/c
4909