Pilot Operated Regulators: Principle of Operation

Pilot operated regulators use a pilot system to modulate inlet pressure based on outlet pressure. Inlet pressure is filtered and reduced to feeding pressure, which exceeds outlet pressure. A pilot valve controls feeding pressure based on outlet pressure sensed by a pilot diaphragm. Modulated pressure then acts on the regulator to adjust flow and match outlet pressure to demand changes. When demand stops, the pilot valve locks to maintain the regulator closed.

Uploaded by

marioLhr
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
395 views1 page

Pilot Operated Regulators: Principle of Operation

Pilot operated regulators use a pilot system to modulate inlet pressure based on outlet pressure. Inlet pressure is filtered and reduced to feeding pressure, which exceeds outlet pressure. A pilot valve controls feeding pressure based on outlet pressure sensed by a pilot diaphragm. Modulated pressure then acts on the regulator to adjust flow and match outlet pressure to demand changes. When demand stops, the pilot valve locks to maintain the regulator closed.

Uploaded by

marioLhr
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Pilot Operated Regulators:

Principle of Operation

Inlet pressure is piped through external tubing to the pilot system. First the inlet pressure is
filtered through a fine filter and pressure is reduced to the outlet pressure plus enough
pressure to overcome the regulator closing spring (feeding pressure).

This feeding pressure is then modulated by the pilot valve: the outlet pressure – sensed by
the pilot sensing line - moves the pilot diaphragm which controls the pilot valve flow.
Modulated pressure (motorization pressure) is piped to the regulator actuator where it opposes
the closing spring and the outlet pressure, and bleeds downstream though a bleed hole.

< As downstream demand increases, outlet pressure drops slightly, and the pilot diaphragm
moves to open further the pilot valve. The motorization pressure increases and moves the
regulator valve thus allowing flow to increase to match the increased demand.

< As downstream demand decreases, outlet pressure increases, moving the pilot diaphragm
to reduce the pilot valve flow. The motorization pressure decreases and regulator closing
spring causes the main valve to move closer to the seat. This restricts flow to match the
decreased demand and recovers desired outlet pressure.

< When demand is shut off, the pilot valve locks up bubble-tight. The regulator closing
spring maintains bubble-tight lockup at the main valve.