Series: 1 " (38mm) DIAMETER Stainless Steel Grab Bars With Snap Flange

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

1½" (38mm) DIAMETER

STAINLESS STEEL GRAB B-6806


Technical Data BARS WITH snap flange SERIES
Specify Finish Required:  Satin finish
 Satin finish with peened gripping surface; add suffix .99 to model number

End Mounting Flange Intermediate Flange

2'' 2-5/8''
50mm 65mm

3-1/8''
80mm
3-1/8''
80mm

2-1/4'' 2-1/4''
55mm
55mm

1-1/2''
38mm

Snap Flange Cover

3-1/4''
85mm 3-1/8''
Dia. 80mm

5/16''
8mm

4''
100mm

36'' 50''
915mm 1270mm
L
L
39-7/8''
1005mm 57-7/8''
1470mm
Edge of
Flange to Wall Edge of
Flange to Wall

TWO-WALL WHEELCHAIR
HORIZONTAL VERTICAL TOILET COMPARTMENT

B-6806 x 12, 18, 24, 30, 36, 42, 48 B-68137

4'' 4'' 4''


100mm 100mm
100mm
42''
24'' 15-7/8'' 1065mm
610mm 405mm
32'' 26-7/8'' 50''
815mm 1270mm
685mm

27-7/8'' 19-3/4'' 45-7/8''


500mm 1165mm
39-7/8'' 710mm 57-7/8''
1470mm
1015mm 34-3/4'' Edge of
Edge of 885mm Flange to Wall
Flange to Wall Edge of
Edge of Flange to Wall
Flange to Wall Edge of Edge of
Flange to Wall Flange to Wall

HORIZONTAL TUB / SHOWER / TOILET HORIZONTAL TWO-WALL BAR TWO-WALL


COMPARTMENT BAR 24 x 36 for Shower Stall TOILET COMPARTMENT BAR 42 x 54
B-68616 B-6861 B-6897

continued . . .

The illustrations and descriptions herein are applicable to production as of the date of this Technical Data Sheet. Rev. 7/29/16 S/B    Printed in U.S.A.
The manufacturer reserves the right to, and does from time to time, make changes and improvements in designs and dimensions. © 2016 by Bobrick Washroom Equipment, Inc.
materials:
Grab Bar — 18-8 S, type-304, 18-gauge (1.2mm) stainless steel tubing with satin-finish. 1-1/2" (38mm) outside diameter. Ends are heliarc welded to flanges.
Clearance between the grab bar and wall is 1-1/2" (38mm).
Concealed Mounting Flanges — 18-8 S, type-304, 11-gauge (3.2mm) thick, stainless steel plate; end flanges 2" x 3-1/8" (50 x 80mm) with holes for
attachment to wall. Intermediate flanges 2-5/8" x 3-1/8" (65 x 80mm) wide x 3-1/8" (80mm) diameter.
Snap Flange Covers — 18-8 S, type-304, 22-gauge (0.8mm) drawn stainless steel with satin-finish. 3-1/4" (85mm) diameter x 1/2" (13mm) deep. Each cover
snaps over mounting flange to conceal mounting screws.
strength:
Bobrick grab bars that provide 1-1/2" (38mm) clearance from wall can support loads in excess of 900 pounds (408kg) if properly installed. Other grab bar
configurations can support loads in excess of 250 pounds (113kg) if properly installed, complying with accessible design (including ADAAG in the U.S.A.) for
structural strength
Safety Warning: Grab bars are no stronger than the anchors and walls to which they are attached and, therefore, must be firmly
secured in order to support the loads for which they are intended. To avoid potential injur y, the building owner or maintenance
personnel should remove the grab bar from ser vice if the grab bar is not adequately secured to wall or if there is any obser ved
damage to the welds.
installation:
Provide concealed anchor device or backing as specified or required in accordance with local building codes before wall is finished. Fasten concealed
mounting flanges to anchor device or backing with at least two screws opposing each other in each flange. Snap flange covers over each mounting flange to
conceal mounting screws. Concealed anchor devices and mounting screws are not included with Bobrick grab bars and must be specified as an accessory.
For Grab Bars with an Intermediate Flange(s), Pull Snap-Flange Covers away from mounting flanges. Place grab bar in desired mounting location. Use
intermediate flange as a template to mark location of mounting screws at intermediate flange only. Mark screw locations at the center of the slot in the middle
of the double-keyhole shaped mounting holes (2) in the intermediate flange. Remove grab bar from wall. Drive the intermediate flange mounting screws into
wall at marked locations. Note: Make sure to leave a space of just over 1/8'' (3.17mm) between the underside of the screw head and the wall. Install grab
bar on the wall by placing the round ends of the intermediate flange double-keyhole shaped mounting holes over the mounting screws (2) are located in the
middle of the flange slots. Install the mounting screws into the wall at the end flanges and secure tightly. Tighten the mounting screws at the intermediate
flange. Press all snap-flange covers into place to conceal mounting flanges.
Note: Recommend use of 1/4'' or #14 sheet metal or wood screws to install Intermediate Flange. #12 screws may also be used.
Important Notes:
1. Mounting Kits — Bobrick offers a mounting kit for installing grab bars; one Bobrick mounting kit is required for each flange.

Mounting Kit No. Description


252-30 Consists of # (3) 14 x 2½'' type-304 stainless steel,
Phillips round-head, sheet-metal screws.

2. Grab Bar Fastener — Bobrick offers a grab bar fastening system that secures all Bobrick grab bar series; one Bobrick fastener is required for
each flange. Install grab bar without backing in wall requires minimum 5/8" (16mm) thick painted or tiled drywall.

WingIt™ Fastener No. Description


251-4 Consists of 10–32 x 5/16'' round-head, Phillips 18/8 stainless steel screws.
(1) WingIt grab bar fastener.

3. Optional Anchor Device — Bobrick grab bar anchor device includes stainless steel machine screws to be used for attaching grab bars to anchors.
one Bobrick concealed anchor device is required for each flange.

Optional Anchor No. Description


2583 Anchor for 3/4" to 1" (19-25mm) panel
1 anchor required for each flange.
2586 Anchor for 1/2" to 1" (13mm) panel
1 anchor required for each flange.

specification:
Grab bar shall be type-304 stainless steel with satin-finish. Grab bar shall have 18-gauge (1.2mm) wall thickness and 1-1/2" (38mm) outside diameter.
Clearance between the grab bar and wall shall be 1-1/2" (38mm). Concealed mounting flanges shall be 11-gauge (3.2mm) thick stainless steel plate, 2" x
3-1/8" (50 x 80mm), and equipped with at least two screw holes for attachment to wall. Flange covers shall be 22 gauge (0.8mm), 3-1/4" (85mm) diameter x
1/2" (13mm) deep, and shall snap over mounting flange to conceal mounting screws and/or WingIt fasteners. Ends of grab bar shall pass through concealed
mounting flanges and be heliarc welded to form one structural unit. Grab bar shall comply with accessible design (including ADAAG in the U.S.A.) for
structural strength.

Grab Bar shall be Model __________ (insert model number) of Bobrick Washroom Equipment, Inc., Clifton Park, New York; Jackson,
Tennessee; Los Angeles, California; Bobrick Washroom Equipment Company, Scarborough, Ontario; Bobrick Washroom Equipment Pty. Ltd.,
Australia; and Bobrick Washroom Equipment Limited, United Kingdom.

The illustrations and descriptions herein are applicable to production as of the date of this Technical Data Sheet. B-6806  Rev. 7/29/16 S/B Printed in U.S.A.
The manufacturer reserves the right to, and does from time to time, make changes and improvements in designs and dimensions. © 2016 by Bobrick Washroom Equipment, Inc.

You might also like