Flujometros Pitot
Flujometros Pitot
Flujometros Pitot
Type ITA
ITA with ITA with mA-Output and Digital Display ITA with Steam
Alumium- with Volume Linearization Jacket
Indication-Rail
and Switch
Technical Catalogue
List of Contents
1. ISO 9001-certificate 1
4. Equipment 190
4.1 ITA-3 Cryo, ITA-3 CR64 190
4.2 Armaflex£-insulation 191
4.3 Heat insulation 192
4.4 Technical data switches 193
4.5 Contact NJ-EX 195
4.6 Indication rails 197
4.7 Niveau-source 198
4.8 Reed-contact 199
4.9 Digital Indication with mag. Level Gauges type ITA and Reed Chain 200
4.10 Magnetostrictive level transmitter 203
4.10 Transmitter 205
Order codes:
For mag. level gauges
(behind each subchapter of chapter 3)
For add. Equipment 216
For special designs 220
For spare parts 221
For documentation 230
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
1
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Functional Principle:
A float chamber (2) is connected (1A and 1B) to the tank (1), and following the law of communicating
tubes, the level in the float chamber is equal to the level of the tank. The float (3) follows the fluid
level and transmits its movements contact-free to the indication rail (4) mounted on the outside. The
float has a special magnet, which rotates the wafers by 180° as it passes them. The result is a clearly
defined level indication, with the level shown in a continuous red stripe strongly contrasted to the
white above. At increasing levels the color of the wafer changes from white to red and vice versa.
The indication rail and the wafers are made of Makrolon so that there will never be a problem of
corrosion in humid and aggressive atmosphere. Each wafer has a permanent magnet, that is why the
indicator is shock proof. Moreover, as there is no turbidness because of product contamination of the
UV-radiation, the readability remains unobjectable even after some years.
All models are available with electronic alarms, which can be mounted at any position during
operation of the system, which renders possible an optimal definition of the min. and max. data
points. The indicator can be equipped with a scale for volume or height (depending on the customer’s
specifications).
2
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
2.3 Advantages
No risk of glass breakage as a result of the separation of the measurement and indicator areas. The
float principle means that changes of the density in the medium have very little influence on the
indication accuracy.
The switches / alarm contacts are secured with pipe clips, and
can be adjusted to any desired height. The connection is using 3-
core cable or casing terminals. The changeover contact can be
used as opener or closer. The switches are also available as
explosion-proof version.
2.5 Floats
3
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
The ITA level gauges can be supplied with indication rails made from 2 different materials. Makrolon
indication rails are resistible to breakage. The max. permissible media temperature is 120°C, with
20°C ambient temperature and natural convection as test conditions. The rails are resistible to UV-
radiation and aggressive atmospheres and are sealed against dust by two seal-caps. Aluminum
indication rails can be supplied as one part rail up to a length of 6 m. The sight cover material
depends on the temperature, up to 150°C the material is Makrolon and up to 400°C it is glass. The
surface of the indication rail can b coated with Saekaphen if required, the standard surface is brown-
anodized.
2.7 Materials
The gauge chamber and the floats are made of stainless steel (1.4571), 254SMO (1.4529), titanium,
Hasteloy, PVC, PP, PVDF and PTFE. Other materials on request.
4
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
5
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.1.1 ITA-3
Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug
6
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
7
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.1.2 ITA-3.0
Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug
8
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
9
3.1.3 Pressure-Temperature Table ITA-3 (Float pipe)
10
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes mag. level gauge type ITA- 3 & ITA-3.0 PN16/150 lbs
Code Description
11
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes mag. level gauge type ITA- 3 & ITA-3.0 PN16/150 lbs
Code Description
12
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes mag. level gauge type ITA- 3 & ITA-3.0 PN16/150 lbs
Code Description
13
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes mag. level gauge type ITA- 3 & ITA-3.0 PN16/150 lbs
Code Bezeichnung
14
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes mag. level gauge type ITA- 3 & ITA-3.0 PN16/150 lbs
Code Description
15
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes mag. level gauge type ITA- 3 & ITA-3.0 PN16/150 lbs
Code Description
16
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Prices for mag. Level Gauges type: ITA-3 & ITA-3.0 PN16/150 lbs
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
3V0100K1 16 316SS 52 125 1,4907 N
3V0100K3 16 316SS 52 125 1,0524 N only with 316SS or Aluminium indication rail
3V0120K1 16 316SS 52 145 1,2346 N
3V0120K3 16 316SS 52 145 0,9034 N only with 316SS or Aluminium indication rail
3V0150K1 16 316SS 52 175 0,9905 N
3V0150K3 16 316SS 52 175 0,8606 N only with 316SS or Aluminium indication rail
3V0180K1 16 316SS 52 205 0,8781 N
3V0180K3 16 316SS 52 205 0,7022 N only with 316SS or Aluminium indication rail
3V0240K1 16 316SS 52 265 0,7374 N
3V0240K3 16 316SS 52 265 0,6209 N only with 316SS or Aluminium indication rail
3V1240K1 40 316SS 52 265 1,000 N
3T0100K1 16 Titanium 50,8 125 1,1788 N do not use with hydrogen or alcohol compounds
3T0100K3 16 Titanium 50,8 125 0,7821 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0120K1 16 Titanium 50,8 145 0,9646 N do not use with hydrogen or alcohol compounds
3T0120K3 16 Titanium 50,8 145 0,6514 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0150K1 16 Titanium 50,8 175 0,7763 N do not use with hydrogen or alcohol compounds
3T0150K3 16 Titanium 50,8 175 0,5675 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0180K1 16 Titanium 50,8 205 0,6716 N do not use with hydrogen or alcohol compounds
3T0180K3 16 Titanium 50,8 205 0,5094 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0240K1 16 Titanium 50,8 265 0,5723 N do not use with hydrogen or alcohol compounds
3T0240K3 16 Titanium 50,8 265 0,4550 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0300K1 16 Titanium 50,8 325 0,4955 N do not use with hydrogen or alcohol compounds
3T0300K3 16 Titanium 50,8 325 0,4063 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0400K1 16 Titanium 50,8 425 0,4358 N do not use with hydrogen or alcohol compounds
3T0400K3 16 Titanium 50,8 425 0,3719 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0500K1 16 Titanium 50,8 525 0,4017 N do not use with hydrogen or alcohol compounds
3T0500K3 16 Titanium 50,8 525 0,3539 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0600K1 16 Titanium 50,8 625 0,3761 N do not use with hydrogen or alcohol compounds
3T0600K3 16 Titanium 50,8 625 0,3371 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3H0150K1 16 Titanium, 52 175 0,902 N
Halar-coated
3HC012K1 16 Hastelloy C4 52 175 1,2455 N
3HC024K1 16 Hastelloy C4 52 265 0,7510 N
3HC024K3 16 Hastelloy C4 52 265 0,6296 N only with 316SS or Aluminium indication rail
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
17
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-3
ITA-3.0
18
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Drain plug
2 c to c distance 10 Additional drain flange, open
3 Design (indication rail) 11 Float pipe top end finish
4 Armaflex£ insulation 12 Vent plug
6 Process connection side/side 13 Counter flanges
7 Side studs welded with T pieces 14 Additional bracket
for 100 % X-ray testing 15 Float pipe seamless
8 Float removal flange 16 Float
19
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
20
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Code Description
Code Description
22
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Code Description
23
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Code Description
11.2 Bolts & nuts float pipe top end finish flange (only DN50 or 2")
0 without (Float removal flange (bottom side) = end cap)
63 M16 x 65 mm; mat. zinced steel; flange DN 50 PN 16; DIN 931
64 M16 x 65 mm; mat. A2-70; flange DN 50 PN 16;K DIN 931
3X M16 x 65 mm, PTFE-coated, flanges DN 50 PN 16
3A 5/8" x 83 mm;RF, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3B 5/8" x 83 mm;RF, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3C 5/8" x 95 mm;RTJ, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3D 5/8" x 95 mm;RTJ, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3T 5/8" x 83 mm;RF, mat.: PTFE coated, flange 2" 150 lbs
3V 5/8" x 95 mm;RTJ, mat.: PTFE coated, flange 2" 150 lbs
12. Vent plug at top end
0 without
1 Vent plug G 1/2" with soft iron gasket
2 Vent plug 1/2" NPT
3 Vent plug 3/4" NPT
4 Vent plug 1" NPT
12.1 Vent flange welded to end cap instead of vent plug
0 without
1 Flanged DN 15 PN 16 (socket weld construction to endcap)
2 Flanged DN 20 PN 16 (socket weld construction to endcap)
3 Flanged DN 25 PN 16 (socket weld construction to endcap)
4 Flanged DN 32 PN 16 (socket weld construction to endcap)
5 Flanged DN 40 PN 16 (socket weld construction to endcap)
6 Flanged DN 50 PN 16 (socket weld construction to endcap)
A Flanged 1/2" ANSI 150 lbs (socket weld construction to endcap)
B Flanged 3/4" ANSI 150 lbs (socket weld construction to endcap)
C Flanged 1" ANSI 150 lbs (socket weld construction to endcap)
D Flanged 1 1/4" ANSI 150 lbs (socket weld construction to endcap)
E Flanged 1 1/2" ANSI 150 lbs (socket weld construction to endcap)
12.2 Surface vent flange welded to end cap (only DN50 or 2")
0 without (Vent flange welded to end cap = without)
B Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (ANSI)
F Surface groove (DIN2512)
G Surface groove large ANSI
H Surface tongue (DIN2512)
K Surface tongue-large ANSI
L Surface RTJ (ANSI) 1/2" bis 2"
24
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Code Description
25
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Code Description
Floats
26
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-3-Cryo
27
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Key:
1 Float pipe welded, dimensions 64 x 2 mm 9 Drain plug
2 c to c distance 10 Additional drain flange, open
3 Design (indication rail) 11 Float pipe top end finish
4 Armaflex insulation 12 Vent plug
6 Process connection side/side 13 Counter flanges
7 Side studs welded with T pieces 14 Additional bracket
for 100 % X-ray testing 15 Float pipe seamless
8 Float removal flange 16 Float
28
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
29
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-3-CR64 for cryogenic applications
Code Description
30
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-3-CR64 for cryogenic applications
Code Description
8.1 Surface float removal flange (bottom side) (only DN50 or 2")
0 without (Float removal flange (bottom side) = end cap or < DN50 or 2")
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
8.2 Bolts & nuts float removal flange (bottom side)
0 without (Float removal flange (bottom side) = end cap)
63 M16 x 65 mm; mat. zinced steel; flange DN 50 PN 16; DIN 931
64 M16 x 65 mm; mat. A2-70; flange DN 50 PN 16;K DIN 931
3X M16 x 65 mm, PTFE-coated, flanges DN 50 PN 16
3A 5/8" x 83 mm;RF, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3B 5/8" x 83 mm;RF, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3C 5/8" x 95 mm;RTJ, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3D 5/8" x 95 mm;RTJ, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3T 5/8" x 83 mm;RF, mat.: PTFE coated, flange 2" 150 lbs
3V 5/8" x 95 mm;RTJ, mat.: PTFE coated, flange 2" 150 lbs
9. Drain plug
0 without
1 Drain plug G 1/2" with soft iron gasket
2 Drain plug 1/2" NPT
3 Drain plug 3/4" NPT
4 Drain plug 1" NPT
10. Additional drain flange, open
0 without
1 Drain stud with flange DN 15 PN 16
2 Drain stud with flange DN 20 PN 16
3 Drain stud with flange DN 25 PN 16
4 Drain stud with flange DN 32 PN 16
5 Drain stud with flange DN 40 PN 16
6 Drain stud with flange DN 50 PN 16
A Drain stud with flange 1/2" ANSI 150 lbs
B Drain stud with flange 3/4" ANSI 150 lbs
C Drain stud with flange 1" ANSI 150 lbs
D Drain stud with flange 1 1/4" ANSI 150 lbs
E Drain stud with flange 1 1/2" ANSI 150 lbs
F Drain stud with flange 2" ANSI 150 lbs
31
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-3-CR64 for cryogenic applications
Code Description
32
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-3-CR64 for cryogenic applications
Code Description
33
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-3-CR64 for cryogenic applications
Code Description
34
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
3C0501K1 16 Titanium 50,8 525 0,4017 N with spacers;
do not use for hydrogen or alcohol compounds
3C0501K2 16 Titanium 50,8 525 0,389 N with spacers;
do not use for hydrogen or alcohol compounds
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
35
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-3-CR64
36
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.4.1 ITA-3.5
Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Additional bracket
2 c to c distance 10 Float pipe seamless
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Float
6 Float removal flange
7 Additional drain flange, open
8 Float pipe top end finish
37
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
38
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA- 3.5 PN16/150 lbs
Code Description
39
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA- 3.5 PN16/150 lbs
Code Description
40
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA- 3.5 PN16/150 lbs
Code Description
41
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. Level Gauges type: ITA-3.5 PN16/150 lbs
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
35H024K1 16 Titanium, 52 240 0,6873 N
Halar-
coated
35H024K3 16 Titanium, 52 240 0,5645 N only with 316SS or Aluminium indication rail
Halar-
coated
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
42
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-3.5
43
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.5.1 ITA-3.8
Characteristics:
Float pipe and flange material 1.4404
wetted parts E-TFE-lined
applicable for vacuum service
Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Additional bracket
2 c to c distance 10 Float pipe seamless
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Float
6 Float removal flange
7 Additional drain flange, open
8 Float pipe top end finish
44
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
45
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauges type ITA- 3 PN16/150 lbs
Code Description
46
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauges type ITA- 3 PN16/150 lbs
Code Description
47
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. Level Gauges type: ITA-3.5 PN16/150 lbs
Description
Floats
Code Pressure Material Diameter Length min. Density vented Notes
[bar] [mm] [mm] [kg/dm³] [Y/N]
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
48
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-3.8
49
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.6.1 ITA-4
Key:
1 Float pipe welded, dimensions 60,3 x 2 mm
2 Measuring length
3 Design (indication rail)
5 Process connection on tank
6 Follower magnet giude tube top side finish
7 Float with rod and follower magnet
50
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
51
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.6.2 ITA-4.0
Key:
1 Float pipe welded, dimensions 60,3 x 2 mm
2 Measuring length
3 Design (indication rail)
5 Process connection on tank
6 Follower magnet giude tube top side finish
7 Float with rod and follower magnet
52
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
53
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order code for mag. level gauge type ITA-4 & ITA-4.0 PN 16 / 150 lbs
Code Description
ITA-4 1. Float pipe welded
Dimensions 60,3 x 2 mm
2. Measuring length
L Measuring lenght in mm ( max. 2750 mm, depending on the density of the fluid)
3. Design
0 without indication rail, each 100 mm
1 Indication rail material: Makrolon, max. 120 °C fluid temperature, each 100 mm
2 Indication rail material: Aluminium, max. 400 °C fluid temperature, each 100 mm
3 Indication rail material: 1.4401, max. 400 °C fluid temperature, each 100 mm
4. Two-parts-construction
0 without
1 Connection of the follower magnet guide tube DN50 PN16
2 Connection of the follower magnet guide tube 2" ANSI 150 lbs RF
5. Process connection on tank
1 Flange DN 50/PN 16
2 Flange DN 80/PN 16
3 Flange DN 100/PN 16
4 Flange DN 125/PN 16
5 Flange DN 150/PN 16
6 Flange DN 200/PN 16
A Flange 2" ANSI/150 lbs
B Flange 3" ANSI/150 lbs
C Flange 4" ANSI/150 lbs
D Flange 5" ANSI/150 lbs
E Flange 6" ANSI/150 lbs
F Flange 8" ANSI/150 lbs
5.1 Surface of the process connection on tank
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smouth finished)
F Surface groove (DIN 2512)
G Surface groove large
H Surface Feder (DIN 2512)
K Surface tongue-large
54
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order code for mag. level gauge type ITA-4 & ITA-4.0 PN 16 / 150 lbs
Code Description
6. Follower magnet guide tube topside finish
1 Flange with blind flange DN32 PN 16
2 Flange with blind flange DN50 PN 16
A Flange with blind flange 1 1/4" ANSI 150 lbs
B Flange with blind flange 2" ANSI 150 lbs
Floats
Code Pressure Material Diameter Length min. vented max. Notes
[bar] [mm] [mm] Density* [Y/N] rod length
[kg/dm³] [mm]
4V0240R1A 16 316L 52,0 265 0,9500 N 500
4V0240R1B 16 316L 52,0 265 1,0000 N 750
4T0240R1A 16 Titanium 50,8 265 0,6890 N 500 do not use with hydrogen or alcohol compounds
4T0240R1B 16 Titanium 50,8 265 0,7250 N 750 do not use with hydrogen or alcohol compounds
4T0240R1C 16 Titanium 50,8 265 0,7610 N 1000 do not use with hydrogen or alcohol compounds
4T0240R1D 16 Titanium 50,8 265 0,7970 N 1250 do not use with hydrogen or alcohol compounds
4T0240R1E 16 Titanium 50,8 265 0,8330 N 1500 do not use with hydrogen or alcohol compounds
4T0240R1F 16 Titanium 50,8 265 0,8690 N 1750 do not use with hydrogen or alcohol compounds
4T0240R1H 16 Titanium 50,8 265 0,9050 N 2000 do not use with hydrogen or alcohol compounds
4T0240K2A 16 Titanium 50,8 265 0,6480 N 500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K2B 16 Titanium 50,8 265 0,6840 N 750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K2C 16 Titanium 50,8 265 0,7200 N 1000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K2D 16 Titanium 50,8 265 0,7560 N 1250 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K2E 16 Titanium 50,8 265 0,7920 N 1500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K2F 16 Titanium 50,8 265 0,8280 N 1750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K2H 16 Titanium 50,8 265 0,8640 N 2000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3A 16 Titanium 50,8 265 0,5820 N 500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3B 16 Titanium 50,8 265 0,6810 N 750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3C 16 Titanium 50,8 265 0,6540 N 1000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3D 16 Titanium 50,8 265 0,6900 N 1250 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3E 16 Titanium 50,8 265 0,7260 N 1500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3F 16 Titanium 50,8 265 0,7620 N 1750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3H 16 Titanium 50,8 265 0,7980 N 2000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300R1A 16 Titanium 50,8 325 0,601 N 500 do not use with hydrogen or alcohol compounds
4T0300R1B 16 Titanium 50,8 325 0,629 N 750 do not use with hydrogen or alcohol compounds
4T0300R1C 16 Titanium 50,8 325 0,658 N 1000 do not use with hydrogen or alcohol compounds
4T0300R1D 16 Titanium 50,8 325 0,687 N 1250 do not use with hydrogen or alcohol compounds
4T0300R1E 16 Titanium 50,8 325 0,716 N 1500 do not use with hydrogen or alcohol compounds
4T0300R1F 16 Titanium 50,8 325 0,745 N 1750 do not use with hydrogen or alcohol compounds
4T0300R1H 16 Titanium 50,8 325 0,773 N 2000 do not use with hydrogen or alcohol compounds
55
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. Level Gauges type: ITA-4 & ITA-4.0 PN16/150 lbs
Description
Floats
Code Pressure Material Diameter Length min. vented max. Notes
[bar] [mm] [mm] Density* [Y/N] rod length
[kg/dm³] [mm]
4T0300K2A 16 Titanium 50,8 325 0,568 N 500 do not use with hydrogen or alcohol compounds
4T0300K2B 16 Titanium 50,8 325 0,597 N 750 do not use with hydrogen or alcohol compounds
4T0300K2C 16 Titanium 50,8 325 0,625 N 1000 do not use with hydrogen or alcohol compounds
4T0300K2D 16 Titanium 50,8 325 0,654 N 1250 do not use with hydrogen or alcohol compounds
4T0300K2E 16 Titanium 50,8 325 0,683 N 1500 do not use with hydrogen or alcohol compounds
4T0300K2F 16 Titanium 50,8 325 0,712 N 1750 do not use with hydrogen or alcohol compounds
4T0300K2H 16 Titanium 50,8 325 0,741 N 2000 do not use with hydrogen or alcohol compounds
4T0300K3A 16 Titanium 50,8 325 0,5594 N 500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3B 16 Titanium 50,8 325 0,5594 N 750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3C 16 Titanium 50,8 325 0,5594 N 1000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3D 16 Titanium 50,8 325 0,5594 N 1250 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3E 16 Titanium 50,8 325 0,5594 N 1500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3F 16 Titanium 50,8 325 0,5594 N 1750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3H 16 Titanium 50,8 325 0,5594 N 2000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
For additional accessories please refer to the chapters "Special Equipment" and "Electrical Accessories and Switches"
*The min. densities only are valid for temperature = 50 °C and rod dimensions 1000 mm (length) and 6 mm (diameter, standard).
56
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-4
ITA-4.0
57
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.7.1 ITA-4.1
Key:
1 Float pipe welded, dimensions 88,9 x 2 mm
2 Measuring length
3 Design (indication rail)
5 Process connection on tank
6 Follower magnet giude tube top side finish
7 Float with rod and follower magnet
58
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
59
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.7.2 ITA-4.1.0
Key:
1 Float pipe welded, dimensions 88,9 x 2 mm
2 Measuring length
3 Design (indication rail)
5 Process connection on tank
6 Follower magnet giude tube top side finish
7 Float with rod and follower magnet
60
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
61
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-4.1 & ITA-4.1.0 PN 16 / 150 lbs
Code Description
ITA-4.1 1. Float pipe welded
88,9 x 2 mm
2. Measuring length
L Measuring lenght in mm ( max. 2750 mm, depending on the density of the fluid)
3. Design
0 without indication rail, each 100 mm
1 Indication rail material: Makrolon, max. 120 °C fluid temperature, each 100 mm
2 Indication rail material: Aluminium, max. 400 °C fluid temperature, each 100 mm
3 Indication rail material: 1.4401, max. 400 °C fluid temperature, each 100 mm
4. Two-parts-construction
0 without
1 Connection of the follower magnet guide tube DN50 PN16
2 Connection of the follower magnet guide tube 2" ANSI 150 lbs RF
5. Process connection on tank
1 Flange DN 80/PN 16
2 Flange DN 100/PN 16
3 Flange DN 125/PN 16
4 Flange DN 150/PN 16
5 Flange DN 200/PN 16
A Flange 3" ANSI/150 lbs
B Flange 4" ANSI/150 lbs
C Flange 5" ANSI/150 lbs
D Flange 6" ANSI/150 lbs
E Flange 8" ANSI/150 lbs
5.1 Surface of the process connection on tank
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smouth finished)
F Surface groove (DIN 2512)
G Surface groove large
H Surface Feder (DIN 2512)
K Surface tongue-large
62
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-4.1 & ITA-4.1.0 PN 16 / 150 lbs
Code Description
6. Follower magnet guide tube topside finish
1 Flange with blind flange DN32 PN 16
A Flange with blind flange 1 1/2" ANSI 150 lbs
7. Floats
Code Pressure Material Diameter Length min. vented max. Notes
[bar] [mm] [mm] Density* [Y/N] rod length
[kg/dm³] [mm]
4T0152R1A ATM Titanium 80 175 0,4070 N 500 do not use with hydrogen or alcohol compounds
4T0152R1B ATM Titanium 80 175 0,4310 N 750 do not use with hydrogen or alcohol compounds
4T0152R1C ATM Titanium 80 175 0,4540 N 1000 do not use with hydrogen or alcohol compounds
4T0152R1D ATM Titanium 80 175 0,4770 N 1250 do not use with hydrogen or alcohol compounds
4T0152R1E ATM Titanium 80 175 0,5000 N 1500 do not use with hydrogen or alcohol compounds
4T0152R1F ATM Titanium 80 175 0,5240 N 1750 do not use with hydrogen or alcohol compounds
4T0152R1H ATM Titanium 80 175 0,5470 N 2000 do not use with hydrogen or alcohol compounds
4T0152K2A ATM Titanium 80 175 0,4700 N 500 do not use with hydrogen or alcohol compounds
4T0152K2B ATM Titanium 80 175 0,4310 N 750 do not use with hydrogen or alcohol compounds
4T0152K2C ATM Titanium 80 175 0,4540 N 1000 do not use with hydrogen or alcohol compounds
4T0152K2D ATM Titanium 80 175 0,4770 N 1250 do not use with hydrogen or alcohol compounds
4T0152K2E ATM Titanium 80 175 0,5000 N 1500 do not use with hydrogen or alcohol compounds
4T0152K2F ATM Titanium 80 175 0,5240 N 1750 do not use with hydrogen or alcohol compounds
4T0152K2H ATM Titanium 80 175 0,5470 N 2000 do not use with hydrogen or alcohol compounds
4T0152K3A ATM Titanium 80 175 0,4710 N 500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3B ATM Titanium 80 175 0,4940 N 750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3C ATM Titanium 80 175 0,5180 N 1000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3D ATM Titanium 80 175 0,5410 N 1250 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3E ATM Titanium 80 175 0,5640 N 1500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3F ATM Titanium 80 175 0,5870 N 1750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3H ATM Titanium 80 175 0,6100 N 2000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182R1A ATM Titanium 80 205 0,3620 N 500 do not use with hydrogen or alcohol compounds
4T0182R1B ATM Titanium 80 205 0,3810 N 750 do not use with hydrogen or alcohol compounds
4T0182R1C ATM Titanium 80 205 0,4000 N 1000 do not use with hydrogen or alcohol compounds
4T0182R1D ATM Titanium 80 205 0,4200 N 1250 do not use with hydrogen or alcohol compounds
4T0182R1E ATM Titanium 80 205 0,4390 N 1500 do not use with hydrogen or alcohol compounds
4T0182R1F ATM Titanium 80 205 0,4580 N 1750 do not use with hydrogen or alcohol compounds
4T0182R1H ATM Titanium 80 205 0,4780 N 2000 do not use with hydrogen or alcohol compounds
4T0182K2A ATM Titanium 80 205 0,3370 N 500 do not use with hydrogen or alcohol compounds
4T0182K2B ATM Titanium 80 205 0,3570 N 750 do not use with hydrogen or alcohol compounds
4T0182K2C ATM Titanium 80 205 0,3760 N 1000 do not use with hydrogen or alcohol compounds
4T0182K2D ATM Titanium 80 205 0,3950 N 1250 do not use with hydrogen or alcohol compounds
4T0182K2E ATM Titanium 80 205 0,4150 N 1500 do not use with hydrogen or alcohol compounds
4T0182K2F ATM Titanium 80 205 0,3430 N 1750 do not use with hydrogen or alcohol compounds
4T0182K2H ATM Titanium 80 205 0,4530 N 2000 do not use with hydrogen or alcohol compounds
63
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. Level Gauges type: ITA-4.1 & ITA-4.1.0 PN16/150 lbs
Description
Floats
Code Pressure Material Diameter Length min. vented max. Notes
[bar] [mm] [mm] Density* [Y/N] rod length
[kg/dm³] [mm]
4T0182K3A ATM Titanium 80 205 0,3000 N 500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3B ATM Titanium 80 205 0,3190 N 750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3C ATM Titanium 80 205 0,3380 N 1000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3D ATM Titanium 80 205 0,3580 N 1250 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3E ATM Titanium 80 205 0,3770 N 1500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3F ATM Titanium 80 205 0,3960 N 1750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3H ATM Titanium 80 205 0,4160 N 2000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242R1A ATM Titanium 80 265 0,2980 N 500 do not use with hydrogen or alcohol compounds
4T0242R1B ATM Titanium 80 265 0,3120 N 750 do not use with hydrogen or alcohol compounds
4T0242R1C ATM Titanium 80 265 0,3270 N 1000 do not use with hydrogen or alcohol compounds
4T0242R1D ATM Titanium 80 265 0,3410 N 1250 do not use with hydrogen or alcohol compounds
4T0242R1E ATM Titanium 80 265 0,3560 N 1500 do not use with hydrogen or alcohol compounds
4T0242R1F ATM Titanium 80 265 0,3700 N 1750 do not use with hydrogen or alcohol compounds
4T0242R1H ATM Titanium 80 265 0,3850 N 2000 do not use with hydrogen or alcohol compounds
4T0242K2A ATM Titanium 80 265 0,2800 N 500 do not use with hydrogen or alcohol compounds
4T0242K2B ATM Titanium 80 265 0,2940 N 750 do not use with hydrogen or alcohol compounds
4T0242K2C ATM Titanium 80 265 0,3090 N 1000 do not use with hydrogen or alcohol compounds
4T0242K2D ATM Titanium 80 265 0,3230 N 1250 do not use with hydrogen or alcohol compounds
4T0242K2E ATM Titanium 80 265 0,3380 N 1500 do not use with hydrogen or alcohol compounds
4T0242K2F ATM Titanium 80 265 0,3520 N 1750 do not use with hydrogen or alcohol compounds
4T0242K2H ATM Titanium 80 265 0,3670 N 2000 do not use with hydrogen or alcohol compounds
4T0242K3A ATM Titanium 80 265 0,2530 N 500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3B ATM Titanium 80 265 0,2680 N 750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3C ATM Titanium 80 265 0,2820 N 1000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3D ATM Titanium 80 265 0,2970 N 1250 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3E ATM Titanium 80 265 0,3110 N 1500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3F ATM Titanium 80 265 0,3260 N 1750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3H ATM Titanium 80 265 0,3400 N 2000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
64
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. Level Gauges type: ITA-4.1 & ITA-4.1.0 PN16/150 lbs
For additional accessories please refer to the chapters "Special Equipment" and "Electrical Accessories and Switches"
*The min. densities only are valid for temperature = 50 °C and rod dimensions 1000 mm (length) and 6 mm (diameter, standard).
65
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-4.1
ITA-4.1.0
66
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.8.1 ITA-5
Key:
1 Float pipe welded, dimensions 60,3 x 2 mm
2 Distance between process connections
3 Design (indication rail)
5 Process connection top side
6 Process connection bottom side
7 Float removal flange
67
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
68
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.8.2 ITA-5.0
Key:
1 Float pipe welded, dimensions 60,3 x 2 mm
2 Distance between process connections
3 Design (indication rail)
5 Process connection top side
6 Process connection bottom side
7 Float removal flange
69
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
70
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Prices for mag. level gauge type ITA-5 & ITA- 5.0 PN 16/40 / 150 lbs/300 lbs*
Code Description
ITA-5 1. Float pipe welded
ITA-5.0 Dimensions 60,3x2 mm
2. Distance between process connections
L Distance between process connections in mm
3. Design
0 without indication rail each 100 mm
1 Indication rail material Makrolon, max. 120 °C, each 100 mm
2 Indication rail material Aluminium, max. 400 °C, each 100 mm
3 Indication rail material 1.4401, max. 400 °C, each 100 mm
4. Distance between process connections > 5000 mm
A Dist. betw. process connections < 5000 mm, without connection flanges
B Dist. betw. process connections > 5000 mm, with connection flanges DN 32 PN 16
5. Process connection topside
Y Welding connection (please specify)
Z Female thread (please specify)
1 Flange with blind flange DN 32 PN 16
5.1 Surface of process connection topside
0 without
A Standard-Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
5.2 Bolts & Nuts process connection topside
0 without
31 M16 x 65 mm; mat. zinced steel; flanges DN 32 PN 16; DIN 931
42 M16 x 65 mm; mat. A2-70; flanges DN 32 PN 16; DIN 931
63 M16 x 65 mm; mat. zinced steel; flanges DN 50 PN 16, DIN 931
64 M16 x 65 mm; mat. A2-70; flanges DN 50 PN 16; DIN 931
3X M16 x 65 mm; mat. PTFE-coated; flanges DN 50 PN 16
3Z M16 x 80 mm; mat. PTFE-coated; flanges DN 50 PN 16
41 M16 x 65 mm; mat. zinced steel; flanges DN 32 PN 40; DIN 931
71
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Prices for mag. level gauge type ITA-5 & ITA- 5.0 PN 16/40 / 150 lbs/300 lbs*
Code Description
5.2 Bolts & Nuts process connection topside (Continuation)
32 M16 x 65 mm; mat. A2-70; flanges DN 32 PN 40; DIN 931
43 M16 x 80 mm; mat. zinced steel; flanges DN 32 PN 40, DIN 2510
44 M16 x 80 mm; mat. A2-70; flanges DN 32 PN 40; DIN 2510
65 M16 x 65 mm; mat. zinced steel; flanges DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. A2-70; flanges DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. zinced steel; flanges DN 50 PN 40, DIN 2510
68 M16 x 80 mm; mat. A2-70; flanges DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flanges DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flanges DN 50 PN 40
5.2 Bolts & Nuts process connection topside (Continuation)
3A 5/8 x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" 150 lbs; ANSI B 16.5
3B 5/8 x 83 mm; RF; mat. A193B8/A1948M SS; flange 2" 150 lbs; ANSI B 16.5
3C 5/8 x 95 mm; RTJ; mat. A193B7/A1942H zinced steel; flange 2" 150 lbs; ANSI B 16.5
3D 5/8 x 95 mm; RTJ; mat. A193B8/A1948M SS; flange 2" 150 lbs; ANSI B 16.5
3T 5/8 x 83 mm; RF; mat. PTFE-coated; flange 2" 150 lbs; ANSI B 16.5
3V 5/8 x 95 mm; RTJ; mat. PTFE-coated; flange 2" 150 lbs; ANSI B 16.5
FA 5/8 x 89 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" 300 lbs; ANSI B 16.5
FB 5/8 x 89 mm; RF; mat. A193B8/A1948M SS; flange 2" 300 lbs; ANSI B 16.5
FC 5/8 x 102 mm; RTJ; mat. A193B7/A1942H zinced steel; flange 2" 300 lbs; ANSI B 16.5
FD 5/8 x 102 mm; RTJ; mat. A193B8/A1948M SS; flange 2" 300 lbs; ANSI B 16.5
FT 5/8 x 89 mm; RF; mat. PTFE-coated; flange 2" 300 lbs; ANSI B 16.5
FV 5/8 x 102 mm; RTJ; mat. PTFE-coated; flange 2" 300 lbs; ANSI B 16.5
6. Process connection bottom side
Y Welding connection (please specify)
Z Female thread (please specify)
A Flange with blind flange DN 50 PN 16
6.1 Surface of process connection bottom side
0 without
A Standard-Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
72
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Prices for mag. level gauge type ITA-5 & ITA- 5.0 PN 16/40 / 150 lbs/300 lbs*
Code Description
6.2 Bolts & Nuts process connection bottom side
0 without
31 M16 x 65 mm; mat. zinced steel; flanges DN 32 PN 16; DIN 931
42 M16 x 65 mm; mat. A2-70; flanges DN 32 PN 16; DIN 931
63 M16 x 65 mm; mat. zinced steel; flanges DN 50 PN 16, DIN 931
64 M16 x 65 mm; mat. A2-70; flanges DN 50 PN 16; DIN 931
3X M16 x 65 mm; mat. PTFE-coated; flanges DN 50 PN 16
3Z M16 x 80 mm; mat. PTFE-coated; flanges DN 50 PN 16
41 M16 x 65 mm; mat. zinced steel; flanges DN 32 PN 40; DIN 931
32 M16 x 65 mm; mat. A2-70; flanges DN 32 PN 40; DIN 931
43 M16 x 80 mm; mat. zinced steel; flanges DN 32 PN 40, DIN 2510
44 M16 x 80 mm; mat. A2-70; flanges DN 32 PN 40; DIN 2510
65 M16 x 65 mm; mat. zinced steel; flanges DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. A2-70; flanges DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. zinced steel; flanges DN 50 PN 40, DIN 2510
68 M16 x 80 mm; mat. A2-70; flanges DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flanges DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flanges DN 50 PN 40
3A 5/8 x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" 150 lbs; ANSI B 16.5
3A 5/8 x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" 150 lbs; ANSI B 16.5
3B 5/8 x 83 mm; RF; mat. A193B8/A1948M SS; flange 2" 150 lbs; ANSI B 16.5
3C 5/8 x 95 mm; RTJ; mat. A193B7/A1942H zinced steel; flange 2" 150 lbs; ANSI B 16.5
3D 5/8 x 95 mm; RTJ; mat. A193B8/A1948M SS; flange 2" 150 lbs; ANSI B 16.5
3T 5/8 x 83 mm; RF; mat. PTFE-coated; flange 2" 150 lbs; ANSI B 16.5
3V 5/8 x 95 mm; RTJ; mat. PTFE-coated; flange 2" 150 lbs; ANSI B 16.5
FA 5/8 x 89 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" 300 lbs; ANSI B 16.5
FB 5/8 x 89 mm; RF; mat. A193B8/A1948M SS; flange 2" 300 lbs; ANSI B 16.5
FC 5/8 x 102 mm; RTJ; mat. A193B7/A1942H zinced steel; flange 2" 300 lbs; ANSI B 16.5
FD 5/8 x 102 mm; RTJ; mat. A193B8/A1948M SS; flange 2" 300 lbs; ANSI B 16.5
FT 5/8 x 89 mm; RF; mat. PTFE-coated; flange 2" 300 lbs; ANSI B 16.5
FV 5/8 x 102 mm; RTJ; mat. PTFE-coated; flange 2" 300 lbs; ANSI B 16.5
For additional accessories please go to the chapters "Special equipment" and "Electrical accessories and Switches"
*for higher pressure ratings please see ITA-10 to ITA-13
73
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. Level Gauges type: ITA-5 & ITA-5.0 PN16/150 lbs
Description
Floats
Code Pressur Material Diameter Length min. vented Notes
e [mm] [mm] Density [Y/N]
[bar] [kg/dm³]
3V0100K1 16 316L 52 125 1,4907 N
3V0100K3 16 316L 52 125 1,0524 N only with 316SS or Aluminium indication rail
3V0120K1 16 316L 52 145 1,2346 N
3V0120K3 16 316L 52 145 0,9034 N only with 316SS or Aluminium indication rail
3V0150K1 16 316L 52 175 0,9905 N
3V0150K3 16 316L 52 175 0,8606 N only with 316SS or Aluminium indication rail
3V0180K1 16 316L 52 205 0,8781 N
3V0180K3 16 316L 52 205 0,7022 N only with 316SS or Aluminium indication rail
3V0240K1 16 316L 52 265 0,7374 N
3V0240K3 16 316L 52 265 0,6209 N only with 316SS or Aluminium indication rail
3V1240K1 40 316L 52 265 1,000 N
3T0100K1 16 Titanium 50,8 125 1,1788 N do not use with hydrogen or alcohol compounds
3T0100K3 16 Titanium 50,8 125 0,7821 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0120K1 16 Titanium 50,8 145 0,9646 N do not use with hydrogen or alcohol compounds
3T0120K3 16 Titanium 50,8 145 0,6514 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0150K1 16 Titanium 50,8 175 0,7763 N do not use with hydrogen or alcohol compounds
3T0150K3 16 Titanium 50,8 175 0,5675 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0180K1 16 Titanium 50,8 205 0,6716 N do not use with hydrogen or alcohol compounds
3T0180K3 16 Titanium 50,8 205 0,5094 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0240K1 16 Titanium 50,8 265 0,5723 N do not use with hydrogen or alcohol compounds
3T0240K3 16 Titanium 50,8 265 0,4550 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0300K1 16 Titanium 50,8 325 0,4955 N do not use with hydrogen or alcohol compounds
3T0300K3 16 Titanium 50,8 325 0,4063 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0400K1 16 Titanium 50,8 425 0,4358 N do not use with hydrogen or alcohol compounds
3T0400K3 16 Titanium 50,8 425 0,3719 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0500K1 16 Titanium 50,8 525 0,4017 N do not use with hydrogen or alcohol compounds
3T0500K3 16 Titanium 50,8 525 0,3539 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0600K1 16 Titanium 50,8 625 0,3761 N do not use with hydrogen or alcohol compounds
3T0600K3 16 Titanium 50,8 625 0,3371 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3H0150K1 16 Titanium, 52 175 0,902 N
Halar-coated
3HC012K1 16 Hastelloy C4 52 175 1,2455 N
3HC024K1 16 Hastelloy C4 52 265 0,7510 N
3HC024K3 16 Hastelloy C4 52 265 0,6296 N only with 316SS or Aluminium indication rail
NOTE: The prices for the single parts in the above price list are only meant for the composition of a complete level gauge.
For spare parts prices, please refer to the chapter "Spare parts".
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
FOR HIGHER PRESSURE RATINGS, PLEASE SEE ITA-6 TO ITA-13!
74
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-5
ITA-5.0
75
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.9.1 ITA-6
Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug
76
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
77
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.9.2 ITA-6.0
Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug
78
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
79
3.9.3 Pressure-Temperature Table ITA-6 (Float pipe)
80
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-6 & ITA-6.0 PN40/300 lbs
Code Description
81
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-6 & ITA-6.0 PN40/300 lbs
Code Description
82
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-6 & ITA-6.0 PN40/300 lbs
Code Description
83
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-6 & ITA-6.0 PN40/300 lbs
Code Description
10.1 Surface float pipe top end finish flange (only DN50 or 2") (Continuation)
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
10.2 Bolts & nuts float pipe top end finish flange
0 without (Float removal flange (bottom side) = end cap)
41 M16 x 65 mm; mat. CS zinced; flange DN 32 PN 40; DIN 931
42 M16 x 65 mm; mat. SS 1.4301; flange DN 32 PN 40; DIN 931
43 M16 x 80 mm; mat. CS zinced; flange DN 32 PN 40; DIN 2510
44 M16 x 80 mm; mat. SS 1.4301; flange DN 32 PN 40; DIN 2510
65 M16 x 65 mm; mat. CS zinced; flange DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. CS zinced; flange DN 50 PN 40; DIN 2510
68 M16 x 80 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flange DN 50 PN 40
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5
11. Vent plug at top end
0 without
1 Vent plug G 1/2" with soft iron gasket
2 Vent plug 1/2" NPT
3 Vent plug 3/4" NPT
4 Vent plug 1" NPT
11.1 Vent flange welded to end cap instead of vent plug
0 without
1 Flanged DN 15 PN 40 (socket weld construction to endcap)
2 Flanged DN 20 PN 40 (socket weld construction to endcap)
3 Flanged DN 25 PN 40 (socket weld construction to endcap)
4 Flanged DN 32 PN 40 (socket weld construction to endcap)
5 Flanged DN 40 PN 40 (socket weld construction to endcap)
6 Flanged DN 50 PN 40 (socket weld construction to endcap)
A Flanged 1/2" ANSI 300 lbs (socket weld construction to endcap)
B Flanged 3/4" ANSI 300 lbs (socket weld construction to endcap)
C Flanged 1" ANSI 300 lbs (socket weld construction to endcap)
D Flanged 1 1/4" ANSI 300 lbs (socket weld construction to endcap)
E Flanged 1 1/2" ANSI 300 lbs (socket weld construction to endcap)
F Flanged 2" ANSI 300 lbs (socket weld construction to endcap)
84
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-6 & ITA-6.0 PN40/300 lbs
Code Description
85
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-6 & ITA-6.0 PN40/300 lbs
Code Description
86
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. Level Gauges type: ITA-6 & ITA-6.0 PN40/300 lbs
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
6V0100K1 30 316L 52 125 1,5188 N
6V0100K3 30 316L 52 125 1,0891 N only with 316SS or Aluminium indication rail
6V0120K1 30 316L 52 145 1,2780 N
6V0120K3 30 316L 52 145 0,9519 N only with 316SS or Aluminium indication rail
6V0150K1 30 316L 52 175 1,0711 N
6V0150K3 30 316L 52 175 0,8309 N only with 316SS or Aluminium indication rail
6V0180K1 30 316L 52 205 0,9486 N
6V0180K3 30 316L 52 205 0,8140 N only with 316SS or Aluminium indication rail
6V0240K1 30 316L 52 265 0,7738 N
6V0240K3 30 316L 52 265 0,6513 N only with 316SS or Aluminium indication rail
6T0100K1 40 Titanium 50,8 125 1,3114 N do not use for hydrogen and alcohol compounds
6T0100K3 40 Titanium 50,8 125 0,8975 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds
6T0120K1 40 Titanium 50,8 145 1,1007 N do not use for hydrogen and alcohol compounds
6T0120K3 40 Titanium 50,8 145 0,7837 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds
6T0150K1 40 Titanium 50,8 175 0,9029 N do not use for hydrogen and alcohol compounds
6T0150K3 40 Titanium 50,8 175 0,6763 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds
6T0180K1 40 Titanium 50,8 205 0,7791 N do not use for hydrogen and alcohol compounds
6T0180K3 40 Titanium 50,8 205 0,6100 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds
6T0240K1 40 Titanium 50,8 265 0,6391 N do not use for hydrogen and alcohol compounds
6T0240K3 40 Titanium 50,8 265 0,5187 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds
6T0300K1 40 Titanium 50,8 325 0,5694 N do not use for hydrogen and alcohol compounds
6T0300K3 40 Titanium 50,8 325 0,4812 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds
6T0400K1 40 Titanium 50,8 425 0,5300 N do not use for hydrogen and alcohol compounds
6T0400K3 40 Titanium 50,8 425 0,4373 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds
6T0500K1 40 Titanium 50,8 525 0,4463 N do not use for hydrogen and alcohol compounds
6T0500K3 40 Titanium 50,8 525 0,4098 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds
6T0600K1 40 Titanium 50,8 625 0,4370 N do not use for hydrogen and alcohol compounds
6T0600K3 40 Titanium 50,8 625 0,3834 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
87
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-6
ITA-6.0
88
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Drain plug
2 c to c distance 10 Additional drain flange, open
3 Design (indication rail) 11 Float pipe top end finish
4 Armaflex£ insulation 12 Vent plug
6 Process connection side/side 13 Counter flanges
7 Side studs welded with T pieces 14 Additional bracket
for 100 % X-ray testing 15 Float pipe seamless
8 Float removal flange 16 Float
89
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
90
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Code Description
91
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Code Description
8.1 Surface float removal flange (bottom side) (only DN50 or 2")
0 without (Float removal flange (bottom side) = end cap or < DN50 or 2")
F Groove (DIN2512)
H Tongue (DIN2512)
8.2 Bolts & Nuts float removal flange
0 without (Float removal flange (bottom side) = end cap)
65 M16 x 65 mm; mat. CS zinced; flange DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. CS zinced; flange DN 50 PN 40; DIN 2510
68 M16 x 80 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flange DN 50 PN 40
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5
9. Drain plug
0 without
1 G 1/2" DIN1910
10. Float pipe top end finish
1 End cap
2 Flange with blind flange DN 50 PN 40
A Flange with blind flange 2" ANSI 300 lbs
10.1 Surface float pipe top end finish flange (only DN50 or 2")
0 without (Float pipe top end finish = End cap or < DN50 or 2")
F Groove (DIN2512)
H Tongue (DIN2512)
10.2 Bolts & nuts float pipe top end finish flange
0 without (Float pipe top end = end cap)
65 M16 x 65 mm; mat. CS zinced; flange DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. CS zinced; flange DN 50 PN 40; DIN 2510
68 M16 x 80 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flange DN 50 PN 40
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5
11. Vent plug on topside
0 without
1 Vent plug G 1/2" with soft iron gasket
92
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Code Description
93
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codees for mag. Level Gauges type: ITA-6-Cryo for cryogenic applications
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
6C0240K1 40 Titanium 50,8 265 0,6391 N without spacers;
do not use with alcohol or hydrogen compounds
6C0400K1 40 Titanium 45 425 0,5981 N with spacers;
do not use with alcohol or hydrogen compounds
6C0500K3 40 Titanium 45 525 0,5486 N with spacers;
only with Aluminium or SS indication rail;
do not use with alcohol or hydrogen compounds
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
94
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-3-Cryo
95
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Key:
1 Float pipe welded, dimensions 64 x 2 mm 9 Drain plug
2 c to c distance 10 Additional drain flange, open
3 Design (indication rail) 11 Float pipe top end finish
4 Armaflex insulation 12 Vent plug
6 Process connection side/side 13 Counter flanges
7 Side studs welded with T pieces 14 Additional bracket
for 100 % X-ray testing 15 Float pipe seamless
8 Float removal flange 16 Float
96
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
97
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-6-CR64 for cryogenic applications
Code Description
98
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-6-CR64 for cryogenic applications
Code Description
8.1 Surface float removal flange (bottom side) (only DN50 or 2")
0 without (Float removal flange (bottom side) = end cap or < DN50 or 2")
F Groove (DIN2512)
H Tongue (DIN2512)
8.2 Bolts & Nuts float removal flange
0 without (Float removal flange (bottom side) = end cap)
65 M16 x 65 mm; mat. CS zinced; flange DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. CS zinced; flange DN 50 PN 40; DIN 2510
68 M16 x 80 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flange DN 50 PN 40
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5
9. Drain plug
0 without
1 G 1/2" DIN1910
10. Float pipe top end finish
1 End cap
2 Flange with blind flange DN 50 PN 40
A Flange with blind flange 2" ANSI 300 lbs
10.1 Surface float pipe top end finish flange (only DN50 or 2")
0 without (Float pipe top end finish = End cap or < DN50 or 2")
F Groove (DIN2512)
H Tongue (DIN2512)
10.2 Bolts & nuts float pipe top end finish flange
0 without (Float pipe top end = end cap)
65 M16 x 65 mm; mat. CS zinced; flange DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. CS zinced; flange DN 50 PN 40; DIN 2510
68 M16 x 80 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flange DN 50 PN 40
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5
99
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-6-CR64 for cryogenic applications
Code Description
100
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. Level Gauges type: ITA-6-CR64 for cryogenic applications
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
6C0240K1 40 Titanium 50,8 265 0,6391 N without spacers;
do not use with alcohol or hydrogen compounds
6C0500K1 40 Titanium 45 525 0,5981 N with spacers;
do not use with alcohol or hydrogen compounds
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
101
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-3-Cryo
102
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.12.1 ITA-7
Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug
103
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
104
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.12.2 ITA-7.0
Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
105
106
3.12.3 Pressure-Temperature Table ITA-7 (Float pipe)
107
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Prices for mag. level gauge type ITA- 7 & ITA-7.0 PN64/300 lbs
Code Description
108
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Prices for mag. level gauge type ITA- 7 & ITA-7.0 PN64/300 lbs
Code Description
109
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Prices for mag. level gauge type ITA- 7 & ITA-7.0 PN64/300 lbs
Code Description
110
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Prices for mag. level gauge type ITA- 7 & ITA-7.0 PN64/300 lbs
Code Description
10.2 Bolts & nuts float pipe top end finish flange (Continuation)
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5
11. Vent plug at top end
0 without
1 Vent plug G 1/2" DIN910
2 Vent plug 1/2" NPT
3 Vent plug 3/4" NPT
4 Vent plug 1" NPT
11.1 Vent flange welded to end cap instead of vent plug
0 without
1 Flange DN 15 PN 63 (socket weld construction to endcap)
2 Flange DN 20 PN 63 (socket weld construction to end cap)
3 Flange DN 25 PN 63 (socket weld construction to end cap)
4 Flange DN 32 PN 63 (socket weld construction to end cap)
5 Flange DN 40 PN 63 (socket weld construction to end cap)
A Flange 1/2" ANSI 300 lbs (socket weld construction to end cap)
B Flange 3/4" ANSI 300 lbs (socket weld construction to end cap)
C Flange 1" ANSI 300 lbs (socket weld construction to end cap)
D Flange 1 1/4" ANSI 300 lbs (socket weld construction to end cap)
E Flange 1 1/2" ANSI 300 lbs (socket weld construction to end cap)
11.2 Vent flange with concentric reducer (X-ray testing)
0 without
1 DN 15 PN 63
2 DN 20 PN 63
3 DN 25 PN 63
4 DN 32 PN 63
5 DN 40 PN 63
A 1/2" ANSI 300 lbs
B 3/4" ANSI 300 lbs
C 1" ANSI 300 lbs
D 1 1/4" ANSI 300 lbs
E 1 1/2" ANSI 300 lbs
11.3 Surface vent flange welded to end cap (only DN50 or 2")
0 without (Vent flange welded to end cap = without)
A Standard- Surface Form C
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
111
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Prices for mag. level gauge type ITA- 7 & ITA-7.0 PN64/300 lbs
Code Description
112
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. Level Gauges type: ITA-7 PN64/300 lbs
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
7T0240K1 64 Titanium 50,8 265 0,6820 N do not use with alcohol or hydrogen compounds
7T0240K3 64 Titanium 50,8 265 0,5551 N only with 316SS or Aluminium indication rail;
do not use with alcohol or hydrogen compounds
7T0300K1 64 Titanium 50,8 325 0,6064 N do not use with alcohol or hydrogen compounds
7T0300K3 64 Titanium 50,8 325 0,5168 N only with 316SS or Aluminium indication rail;
do not use with alcohol or hydrogen compounds
7T0500K3 64 Titanium 50,8 525 0,4450 N only with 316SS or Aluminium indication rail;
do not use with alcohol or hydrogen compounds
7T0600K3 64 Titanium 50,8 625 0,4243 N only with 316SS or Aluminium indication rail;
do not use with alcohol or hydrogen compounds
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
113
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-7
ITA-7.0
114
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Key:
1 Float pipe PVC, dimensions 63 x 47 mm
2 c to c distance
3 Design (indication rail)
6 Process connection side/side
7 Drain plug
8 Float pipe top end finish
9 Mounting link
10 Float
115
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
116
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-8.1 PN6 (PVC)
Code Description
ITA-8.1 1. Float pipe PVC
Dimensions 63 x 4,7 mm
2. C to C distance
L C to C distance in mm
3. Design
0 without indication rail, each 100 mm
1 Indication rail material Aluminium, max. 60 °C liquid temperature, each 100 mm
2 Indication rail material 1.4401, max. 60 °C liquid temperature, each 100 mm
4. C to C distance < 5000 mm
A < 5000 without flange connection DN 32 PN 6
B > 5000 with flange connection DN32 PN 6
5. Reinforcement
0 without reinforcement
Reinforcement of the PVC-guide tube, material: 1.4404, base price
A
+ length dependent price each 100 mm guide tube
6. Process connections side/side
Y Welding connection (please specify)
Z Threaded connection (please specify)
1 Flanges DN 15 PN 6
2 Flanges DN 15 PN 10
3 Flanges DN 20 PN 6
4 Flanges DN 20 PN 10
5 Flanges DN 25 PN 6
6 Flanges DN 25 PN 10
7 Flanges DN 32 PN 6
8 Flanges DN 32 PN 10
9 Flanges DN 40 PN 6
A Flanges DN 40 PN 10
B Flanges DN 50 PN 6
C Flanges DN 50 PN 10
D Flanges 1/2" ANSI 150 lbs
E Flanges 3/4" ANSI 150 lbs
F Flanges 1" ANSI 150 lbs
G Flanges 1 1/4" ANSI 150 lbs
H Flanges 1 1/2" ANSI 150 lbs
K Flanges 2" ANSI 150 lbs
7. Drain plug
0 without
1 Drain plug R1/2"
2 Drain plug 1/2" NPT
3 Drain plug 3/4" NPT
4 Stud on blind flange
117
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-8.1 PN6 (PVC)
Code Description
8. Float pipe top end finish
0 without
A End cap
B Vent plug R1/2"
C Vent plug 1/2" NPT
D Vent plug 3/4" NPT
E Flange DN32 PN6
8.1 Nuts & bolts top end finish flange
0 without
1 M8 x 60 mm; mat. SS 1.4301; DIN 931
9. Mounting link for additional fixing on the tank
0 without
H Mounting link for additional fixing on the tank
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
8PVC01K1 10 PVC 50 135 1,1500 N only with 316SS or Aluminium indication rail
8PVC02K1 10 PVC 50 255 0,7500 N only with 316SS or Aluminium indication rail
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
118
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-8.1
119
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Key:
1 Float pipe PP, dimensions 63 x 47 mm
2 c to c distance
3 Design (indication rail)
6 Process connection side/side
7 Drain plug
8 Float pipe top end finish
9 Mounting link
10 Float
120
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
121
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-8.2 PN6 (PP)
Code Description
ITA-8.1 1. Float pipe PP
Dimensions 63 x 4,7 mm
2. C to C distance
L C to C distance in mm
3. Design
0 without indication rail, each 100 mm
1 Indication rail material Aluminium, max. 80 °C liquid temperature, each 100 mm
2 Indication rail material 1.4401, max. 80 °C liquid temperature, each 100 mm
4. C to C distance < 5000 mm
A < 5000 without flange connection DN 32 PN 6
B > 5000 with flange connection DN32 PN 6
5. Reinforcement
0 without reinforcement
Reinforcement of the PP-guide tube, material: 1.4404, base price
A
+ length dependent price each 100 mm guide tube
6. Process connections side/side
Y Welding connection (please specify)
Z Threaded connection (please specify)
1 Flanges DN 15 PN 6
2 Flanges DN 15 PN 10
3 Flanges DN 20 PN 6
4 Flanges DN 20 PN 10
5 Flanges DN 25 PN 6
6 Flanges DN 25 PN 10
7 Flanges DN 32 PN 6
8 Flanges DN 32 PN 10
9 Flanges DN 40 PN 6
A Flanges DN 40 PN 10
B Flanges DN 50 PN 6
C Flanges DN 50 PN 10
D Flanges 1/2" ANSI 150 lbs
E Flanges 3/4" ANSI 150 lbs
F Flanges 1" ANSI 150 lbs
G Flanges 1 1/4" ANSI 150 lbs
H Flanges 1 1/2" ANSI 150 lbs
K Flanges 2" ANSI 150 lbs
7. Drain plug
0 without
1 Drain plug R1/2"
2 Drain plug 1/2" NPT
3 Drain plug 3/4" NPT
122
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. Level Gauges type: ITA-8.2 PN6 (PP)
Description
8. Float pipe top end finish
A End cap
B Vent plug R1/2"
C Vent plug 1/2" NPT
D Vent plug 3/4" NPT
E Flange DN32 PN6
8.1 Nuts & bolts top end finish flange
0 without
1 M8 x 60 mm; mat. SS 1.4301; DIN 931
9. Mounting link for additional fixing on the tank
0 without
1 Mounting link for additional fixing on the tank
9. Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
8PP001K1 10 PP 50 135 0,9500 N only with 316SS or Aluminium indication rail
8PP002K1 10 PP 50 255 0,6500 N only with 316SS or Aluminium indication rail
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
123
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-8.2
124
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Key:
1 Float pipe PVDF, dimensions 63 x 47 mm
2 c to c distance
3 Design (indication rail)
6 Process connection side/side
7 Drain plug
8 Float pipe top end finish
9 Mounting link
10 Float
125
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
126
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-8.3 PN6 (PVDF)
Code Description
ITA-8.3 1. Float pipe PVDF
Dimensions 63 x 2 mm
2. C to C distance
L C to C distance in mm
3. Design
0 without indication rail, each 100 mm
1 Indication rail material Aluminium, max. 120 °C liquid temperature, each 100 mm
2 Indication rail material 1.4401, max. 120 °C liquid temperature, each 100 mm
4. C to C distance < 5000 mm
A < 5000 without flange connection DN 32 PN 6
B > 5000 with flange connection DN32 PN 6
5. Reinforcement
0 without reinforcement
Reinforcement of the PVDF-guide tube, material: 1.4404, base price
A
+ length dependent price each 100 mm guide tube
6. Process connections side/side
Y Welding connection (please specify)
Z Threaded connection (please specify)
1 Flanges DN 15 PN 6
2 Flanges DN 15 PN 10
3 Flanges DN 20 PN 6
4 Flanges DN 20 PN 10
5 Flanges DN 25 PN 6
6 Flanges DN 25 PN 10
7 Flanges DN 32 PN 6
8 Flanges DN 32 PN 10
9 Flanges DN 40 PN 6
A Flanges DN 40 PN 10
B Flanges DN 50 PN 6
C Flanges DN 50 PN 10
D Flanges 1/2" ANSI 150 lbs
E Flanges 3/4" ANSI 150 lbs
F Flanges 1" ANSI 150 lbs
G Flanges 1 1/4" ANSI 150 lbs
H Flanges 1 1/2" ANSI 150 lbs
K Flanges 2" ANSI 150 lbs
7. Drain plug
0 without
1 Drain plug R1/2"
2 Drain plug 1/2" NPT
3 Drain plug 3/4" NPT
127
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. Level Gauges type: ITA-8.3 PN6 (PVDF)
Description
8. Float pipe top end finish
A End cap
B Vent plug R1/2"
C Vent plug 1/2" NPT
D Vent plug 3/4" NPT
E Flange DN32 PN6
8.1 Nuts & bolts top end finish flange
0 without
1 M8 x 60 mm; mat. SS 1.4301; DIN 931
9. Mounting link for additional fixing on the tank
0 without
1 Mounting link for additional fixing on the tank
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
8PVDF1K1 10 PVDF 50 135 1,3000 N only with 316SS or Aluminium indication rail
8PVDF2K1 10 PVDF 50 255 0,8500 N only with 316SS or Aluminium indication rail
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
128
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-8.3
129
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Key:
1 Float pipe PVC, dimensions 63 x 4,7 mm
2 Measuring length
3 Design (indication rail)
4 Process connection on tank
5 Follower magnet guide tube topside finish
130
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
131
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-9.1 PN 6 (PVC, bis 60 °C)
Code Description
ITA-9.1 1. Float pipe
Dimensions 63 x 4,7 mm
2. Measuring length
L Measuring length in mm (max. 2500 mm, depending on the liquid's density)
3. Design
0 without indication rail, each 100 mm
1 Indication rail material Aluminium, max. 60 °C liquid temperature, each 100 mm
2 Indication rail material 1.4401, max. 60 °C liquid temperature, each 100 mm
4. Process connection onto Tank (FF)
1 Flange DN 80/PN 6
2 Flange DN 100/PN 6
3 Flange DN 150/PN 6
A Flange 3" ANSI/150 lbs
B Flange 4" ANSI/150 lbs
C Flange 6" ANSI/150 lbs
5. Follower magnet guide tube topside finish
1 Vent plug R1/2"
2 Vent plug 1/2"NPT
3 Vent plug 3/4" NPT
4 Flange with blind flange DN32 PN 6
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
9PVC03K1 6 PVC 50 135 N only with 316SS or Aluminium indication rail
NOTE: The prices for the single parts in the above price list are only meant for the composition of a complete level gauge.
For spare parts prices, please refer to the chapter "Spare parts".
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
132
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-9.1
133
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Key:
1 Float pipe PP, dimensions 63 x 3,6 mm
2 Measuring length
3 Design (indication rail)
4 Process connection on tank
5 Follower magnet guide tube topside finish
134
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
135
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauges type ITA-9.2 PN 6 (PP, up to 80 °C)
Code Description
ITA-9.2 1. Float pipe
Dimensions 63 x 3,6 mm
2. Measuring length
L Measuring length in mm (max. 2500 mm, depending on the liquid's density)
3. Design
0 without indication rail, each 100 mm
1 Indication rail material Aluminium, max. 80 °C liquid temperature, each 100 mm
2 Indication rail material 1.4401, max. 80 °C liquid temperature, each 100 mm
4. Process connection onto Tank (FF)
1 Flange DN 80/PN 6
2 Flange DN 100/PN 6
3 Flange DN 150/PN 6
A Flange 3" ANSI/150 lbs
B Flange 4" ANSI/150 lbs
C Flange 6" ANSI/150 lbs
5. Follower magnet guide tube topside finish
1 Vent plug R1/2"
2 Vent plug 1/2"NPT
3 Vent plug 3/4" NPT
4 Flange with blind flange DN32 PN 6
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
9PP030K1 6 PP 50 N only with 316SS or Aluminium indication rail
NOTE: The prices for the single parts in the above price list are only meant for the composition of a complete level gauge.
For spare parts prices, please refer to the chapter "Spare parts".
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
136
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-9.2
137
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Key:
1 Float pipe PVDF, dimensions 63 x 3 mm
2 Measuring length
3 Design (indication rail)
4 Process connection on tank
5 Follower magnet guide tube topside finish
138
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
139
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-9.3 PN 6 (PVDF, up to 120 °C)
Code Description
ITA-9.3 1. Float Pipe
Dimensions 63 x 3 mm
2. Measuring length
L Measuring length in mm (max. 2500 mm, depending on the liquid's density)
3. Design
0 without indication rail, each 100 mm
1 Indication rail material Aluminium, max. 120 °C liquid temperature, each 100 mm
2 Indication rail material 1.4401, max. 120 °C liquid temperature, each 100 mm
4. Process connection onto tank (FF)
1 Flange DN 80/PN 6
2 Flange DN 100/PN 6
3 Flange DN 150/PN 6
A Flange 3" ANSI/150 lbs
B Flange 4" ANSI/150 lbs
C Flange 6" ANSI/150 lbs
5. Follower magnet guide tube topside finish
1 Vent plug R1/2"
2 Vent plug 1/2"NPT
3 Vent plug 3/4" NPT
4 Flange with blind flange DN32 PN 6
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
9PVD03K 6 PVDF 50 N only with 316SS or Aluminium indication rail
NOTE: The prices for the single parts in the above price list are only meant for the composition of a complete level gauge.
For spare parts prices, please refer to the chapter "Spare parts".
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
140
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-9.3
141
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.19.1 ITA-10
Key:
1 Float pipe welded, dimensions 60,3 x 3,2 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug
142
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
143
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.19.2 ITA-10.0
Key:
1 Float pipe welded, dimensions 60,3 x 3,2 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug
144
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
145
3.19.3 Pressure-Temperature Table ITA-10 (Float pipe)
146
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-10 & ITA-10.0 PN100/600 lbs
Code Description
147
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-10 & ITA-10.0 PN100/600 lbs
Code Description
148
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-10 & ITA-10.0 PN100/600 lbs
Code Description
149
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-10 & ITA-10.0 PN100/600 lbs
Code Description
10.2 Bolts & nuts float pipe top end finish flange (Continuation)
FC 5/8" x 108 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 600 lbs; ANSI B16.5
FD 5/8" x 108 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 600 lbs, ANSI B16.5
FT 5/8" x 108 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 600 lbs, ANSI B16.5
FV 5/8" x 108 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 600 lbs; ANSI B16.5
11. Vent plug at top end
0 without
1 Vent plug G 1/2" with soft iron gasket
2 Vent plug 1/2" NPT
3 Vent plug 3/4" NPT
4 Vent plug 1" NPT
11.1 Vent flange welded to end cap instead of vent plug
0 without
1 Flange DN 15 PN 100 (socket weld construction to endcap)
2 Flange DN 25 PN 100 (socket weld construction to endcap)
3 Flange DN 32 PN 100 (socket weld construction to endcap)
4 Flange DN 40 PN 100 (socket weld construction to endcap)
A Flange 1/2" ANSI 600 lbs (socket weld construction to endcap)
B Flange 3/4" ANSI 600 lbs (socket weld construction to endcap)
C Flange 1" ANSI 600 lbs (socket weld construction to endcap)
D Flange 1 1/4" ANSI 600 lbs (socket weld construction to endcap)
E Flange 1 1/2" ANSI 600 lbs (socket weld construction to endcap)
11.2 Vent flange with concentric reducer (X-ray testing)
0 without
1 DN 15 PN 100
2 DN 25 PN 100
3 DN 32 PN 100
4 DN 40 PN 100
A 1/2" ANSI 600 lbs
B 3/4" ANSI 600 lbs
C 1" ANSI 600 lbs
D 1 1/4" ANSI 600 lbs
E 1 1/2" ANSI 600 lbs
11.3 Surface vent flange welded to end cap (only DN50 or 2")
0 without
B Surface Form E Rz=16
D Surface groove (DIN2512)
E Surface tongue (DIN2512)
F Standard-Surface RF
G Surface RFSF (smooth finished)
H Surface groove large
K Surface tongue-large
L Surface RTJ (ANSI)
150
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-10 & ITA-10.0 PN100/600 lbs
Code Description
151
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. Level Gauges type: ITA-10 & ITA-10.0 PN100/600 lbs
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
10V324K3 100 316L 52 265 0,6122 Y only with 316SS or Aluminium indication rail
10T024K1 80 Titanium 50,8 265 0,7011 N do not use for hydrogen or alcohol compounds
10T024K3 80 Titanium 50,8 265 0,5823 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T030K1 80 Titanium 50,8 325 0,6212 N do not use for hydrogen or alcohol compounds
10T030K3 80 Titanium 50,8 325 0,5275 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T040K1 80 Titanium 50,8 425 0,5515 N do not use for hydrogen or alcohol compounds
10T040K3 80 Titanium 50,8 425 0,4871 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T050K1 80 Titanium 50,8 525 0,5095 N do not use for hydrogen or alcohol compounds
10T050K3 80 Titanium 50,8 525 0,4574 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T060K1 80 Titanium 50,8 625 0,4632 N do not use for hydrogen or alcohol compounds
10T060K3 80 Titanium 50,8 625 0,4209 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T124K1 100 Titanium 50,8 265 0,8299 N do not use for hydrogen or alcohol compounds
10T124K3 100 Titanium 50,8 265 0,7006 N only with 316SS or Aluminium indication rail;
Float for high-temperature applications;
do not use for hydrogen or alcohol compounds
10T130K1 100 Titanium 50,8 325 0,7617 N do not use for hydrogen or alcohol compounds
10T130K3 100 Titanium 50,8 325 0,6594 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T140K1 100 Titanium 50,8 425 0,6779 N do not use for hydrogen or alcohol compounds
10T140K3 100 Titanium 50,8 425 0,6075 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T150K1 100 Titanium 50,8 525 0,6321 N do not use for hydrogen or alcohol compounds
10T150K3 100 Titanium 50,8 525 0,5775 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T160K1 100 Titanium 50,8 625 N do not use for hydrogen or alcohol compounds
10T160K3 100 Titanium 50,8 625 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
152
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-10
ITA-10.0
153
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.20.1 ITA-11
Key:
1 Float pipe welded, dimensions 60,3 x 3,91 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug
154
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
155
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.20.2 ITA-11.0
Key:
1 Float pipe welded, dimensions 60,3 x 3,91 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug
156
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
157
3.20.3 Pressure-Temperature Table ITA-11 (Float pipe)
158
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-11 & ITA-11.0 PN160/1500 lbs
Code Description
159
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-11 & ITA-11.0 PN160/1500 lbs
Code Description
160
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-11 & ITA-11.0 PN160/1500 lbs
Code Description
161
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-11 & ITA-11.0 PN160/1500 lbs
Code Description
10.2 Bolts & nuts float pipe top end finish flange (Continuation)
FC 7/8" x 150 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 1500 lbs; ANSI B16.5
FD 7/8" x 150 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FT 7/8" x 150 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 1500 lbs, ANSI B16.5
FV 7/8" x 150 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 1500 lbs; ANSI B16.5
11. Vent plug at top end
0 without
1 Vent plug G 1/2" with soft iron gasket
2 Vent plug 1/2" NPT
3 Vent plug 3/4" NPT
4 Vent plug 1" NPT
11.1 Vent flange welded to end cap instead of vent plug
0 without
1 Flange DN 15 PN 160 (socket weld construction to endcap)
2 Flange DN 25 PN 160 (socket weld construction to endcap)
3 Flange DN 32 PN 160 (socket weld construction to endcap)
4 Flange DN 40 PN 160 (socket weld construction to endcap)
A Flange 1/2" ANSI 1500 lbs (socket weld construction to endcap)
B Flange 3/4" ANSI 1500 lbs (socket weld construction to endcap)
C Flange 1" ANSI 1500 lbs (socket weld construction to endcap)
D Flange 1 1/4" ANSI 1500 lbs (socket weld construction to endcap)
E Flange 1 1/2" ANSI 1500 lbs (socket weld construction to endcap)
11.2 Vent flange with concentric reducer (X-ray testing)
0 without
1 DN 15 PN 160
2 DN 25 PN 160
3 DN 32 PN 160
4 DN 40 PN 160
A 1/2" ANSI 1500 lbs
B 3/4" ANSI 1500 lbs
C 1" ANSI 1500 lbs
D 1 1/4" ANSI 1500 lbs
E 1 1/2" ANSI 1500 lbs
11.3 Surface vent flange welded to end cap (only DN50 or 2")
0 without
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI)
162
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-11 & ITA-11.0 PN160/1500 lbs
Code Description
163
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. Level Gauges type: ITA-11 & ITA-11.0 PN160/1500 lbs
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
11V324K2 160 316L 46 265 0,7736 Y
11T330K2 160 Titanium 46 325 0,4901 Y do not use for hydrogen or alcohol compounds
11T024K1 130 Titanium 45 265 0,86 N do not use for hydrogen or alcohol compounds
11T024K3 130 Titanium 45 265 0,745 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T030K1 130 Titanium 45 325 0,7822 N do not use for hydrogen or alcohol compounds
11T030K3 130 Titanium 45 325 0,6949 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T040K1 130 Titanium 45 425 0,7028 N do not use for hydrogen or alcohol compounds
11T040K3 130 Titanium 45 425 0,6391 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T050K1 130 Titanium 45 525 0,6587 N do not use for hydrogen or alcohol compounds
11T060K1 130 Titanium 45 625 N do not use for hydrogen or alcohol compounds
11T050K3 150 Titanium 45 525 0,6106 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T060K3 150 Titanium 45 625 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T124K3 150 Titanium 46 265 0,7324 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T130K3 150 Titanium 46 325 0,7042 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T140K3 150 Titanium 46 425 0,6164 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T150K3 150 Titanium 46 525 0,6008 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T224K1 160 Titanium 42 265 0,9768 N do not use for hydrogen or alcohol compounds
11T224K3 160 Titanium 42 265 0,812 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T230K1 160 Titanium 42 325 0,8871 N do not use for hydrogen or alcohol compounds
11T230K3 160 Titanium 42 325 0,7613 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T240K1 160 Titanium 42 425 0,7832 N do not use for hydrogen or alcohol compounds
11T240K3 160 Titanium 42 425 0,6934 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T250K1 160 Titanium 42 525 0,7268 N do not use for hydrogen or alcohol compounds
11T250K3 160 Titanium 42 525 0,6571 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T260K1 160 Titanium 42 625 N do not use for hydrogen or alcohol compounds
11T260K3 160 Titanium 42 625 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
164
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-11
ITA-11.0
165
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.21.1 ITA-12
Key:
1 Float pipe welded, dimensions 60,3 x 5,54 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug
166
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
167
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.21.2 ITA-12.0
Key:
1 Float pipe welded, dimensions 60,3 x 5,54 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug
168
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
169
3.21.3 Pressure-Temperature Table ITA-12 (Float pipe)
170
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-12 & ITA-12.0 PN250/1500 lbs
Code Description
171
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-12 & ITA-12.0 PN250/1500 lbs
Code Description
172
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-12 & ITA-12.0 PN250/1500 lbs
Code Description
173
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-12 & ITA-12.0 PN250/1500 lbs
Code Description
174
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-12 & ITA-12.0 PN250/1500 lbs
Code Description
175
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. Level Gauges type: ITA-12 & ITA-12.0 PN250/1500 lbs
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
12V324K1 250 316L 46 265 0,7736 Y
12T324K3 250 Titanium 46 265 0,5526 Y only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T224K1 250 Titanium 42 265 1,0396 N do not use for hydrogen or alcohol compounds
12T224K3 250 Titanium 42 265 0,9659 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T230K1 250 Titanium 42 325 0,9250 N do not use for hydrogen or alcohol compounds
12T230K3 250 Titanium 42 325 0,7978 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T240K1 250 Titanium 42 425 0,8304 N do not use for hydrogen or alcohol compounds
12T240K3 250 Titanium 42 425 0,7394 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T250K1 250 Titanium 42 525 0,7763 N do not use for hydrogen or alcohol compounds
12T250K3 250 Titanium 42 525 0,7055 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T124K3 250 Titanium 38 265 0,8944 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T130K3 250 Titanium 38 325 0,8281 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
NOTE: The prices for the single parts in the above price list are only meant for the composition of a complete level gauge.
For spare parts prices, please refer to the chapter "Spare parts".
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
176
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-12
ITA-12.0
177
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.22.1 ITA-13
Key:
1 Float pipe welded, dimensions 60,3 x 8,7 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug
178
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
179
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
3.22.2 ITA-13.0
Key:
1 Float pipe welded, dimensions 60,3 x 8,7 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug
180
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
181
3.22.3 Pressure-Temperature Table ITA-13 (Float pipe)
182
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-13 & ITA-13.0 PN320/2500 lbs
Code Description
183
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-13 & ITA-13.0 PN320/2500 lbs
Code Description
184
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-13 & ITA-13.0 PN320/2500 lbs
Code Description
185
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-13 & ITA-13.0 PN320/2500 lbs
Code Description
186
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. level gauge type ITA-13 & ITA-13.0 PN320/2500 lbs
Code Description
187
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order codes for mag. Level Gauges type: ITA-13.0 PN320/2500 lbs
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
13V330K3 320 316L 38 325 0,7269 Y only with 316SS or Aluminium indication rail
13T324K3 320 Titanium 38 265 0,5366 Y only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds
13T024K3 320 Titanium 38 265 0,8985 N only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds
13T330K3 320 Titanium 38 325 0,5032 Y only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds
13T040K3 320 Titanium 38 425 0,7582 N only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds
13T050K3 320 Titanium 38 525 N only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
188
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
ITA-13
ITA-13.0
189
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
4. Equipment
distance sleeve
190
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
£-Insulation
4.2 Armaflex£
191
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Technical data:
Composition in %: : 53 % SiO2, 16 % CaO, 13 % Al2O3, 7 % B2O3,
4 % MgO, 1 % Na2 + K2O
Portion organic substance : < 1 % (combust at first heating-up)
Density (g/cm³) : 2,5
Temperature resistance : 500°C/550°C
Degree of moisture : 1%
Annealing loss : 0,6%
Shrinking : 500°C = 0 %
Resistance against : Oil, grease, water, temporary steam
and numerous organic acids/solvents.
Good resistance against sudden heat waves. Good
thermal electrical and acoustical insulation
resistance:
Toxicologically harmless
No handling abligations
192
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
1. General table
2. NI Ex NJ switch
3. Switch diagrams
193
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
194
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Switch Ni Ex NJ
Switch NI-Ex-NJ
195
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Function:
Technical data:
Electrical connection: 8 V DC
Temp./ambient temp. 60 °C
Cable connections: M20x1,5
Swich relay:
196
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Armaflex-insulation and heating tape ITA Indication rail with scale for ITA
Indication rails:
Makrolon Aluminium 316SS
197
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
4.7 Niveau-source
Measuring principle:
The resistance chain with the reed contacts are built in a pipe made of material 316SS. This so-called “Reed-chain”
is mounted on the float chamber with tube clamps. According to the movement of the float, the float magnet closes
one reed contact which produces a voltage (or resistance) proportional to the height of the liquid in the tank.
You get a near-analogous output signal, with a resolution of about 10 mm.
The resistance chain receives it’s power supply from the transmitter. The 4...20 mA transmitter output signal can be
transferred to an indicator or can be used to drive alarm contacts. In the case of an error the output signal becomes
higher than 22 mA.
Connection:
As a standard, the reed chain is supplied with a transmitter that is installed inside the housing-head, 2-wire
connection to the transmitter is only required.
198
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
4.8 Reed-contact
199
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
4.9 Digital Indication with mag. Level Gauges type ITA and Reed-Chain type AVK
Electrical measurement transducers with use the displacement principle have to be re-calibrated each time the fluid
density is changed.
The price of a magnetically controlled level indicator with integral electical measurement transducer is considerably
lower than level measurement transducers.
The reed chain with an R/I-measurement transducer can be replaced without interrupting operation. The measurement
chamber is hermetically sealed - there is non contact between the fluid to be measured and the reed chain.
With the field mounted loop powered indicator, the level can be displayed digitally at the place of measurement.
200
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Features:
4..20 mA-input, loop powered
4-digit LED display in engineering units
Aluminium or 316SS housing
Introduction:
Model 8080HT Loop Powered Digital Indicators allow the process variable from any 4…20 mA current source to be
monitored. Since the unit derives its power from the loop, no additional power supply or wiring is needed. Because
of its low voltage drop (5.3 Volts at 20 mA), it can be incorporated into almost any 2-wire-loop, where local
indication of a process variable is needed, because the integral transmitter indicatore inaccessible to view or is at
a different location.
Description:
Model 8080HT Indicators are designed for use in process industries where vibration, inclement weather and corrosive
atmospheres prevail.The electronics are enclosed in a copper-free epoxy-coated Alumiium housing and for more
aggressive environments, a SS316 housing is available. The housings meet the requirements of NEMA 4X and are
also certified Explosion Proof by FM/CSA.
LED Meter:
The Model 8080HT has a 4-digit display and may be configured to read -999 to 9999 with a 4…20 mA input signal.
The decimal point location and engineering units can be adjusted using membrane switches, eliminating all
potentiometric adjustments.
Specifications:
Indication accuracy: 0.1 % of calibrated range ± 1 digit
Calibration: via membrane switches on the front panel
Display height: 10 mm high LED, user-selectable decimal point
Stability over time: 0.1 % of calibrated range ± 1 digit over 6 months
Over-range indication: Indication fo "HHHH" or "LLLL" blinking on the display
Response time: 0.3~0.5 s
Failure mode: Failure will not affect the loop integrity
Voltage drop: 5.3 Volts at 20 mA
Operating temperature: -50…75 °C
Weight: 0.9 kg (2 lb) Aluminium unit / 1.4 kg (3 lb) 316SS unit
Material of construction: Encl.: epoxy-coated copper-free aluminium or 316 SS
O-Rings: BUNA N
201
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
202
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
M-500 / M-600
Technical data:
203
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order specifications:
M - -
204
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
4.12 Transmitters
Stainless steel
transmitter housing Other types of transmitters on request!
i material: 316Ti
i M20x1,5 entry
205
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
INT5333
2-wire
programmable transmitter
Application:
- Linearized temperature measurement with Pt100…Pt1000 or Ni100…Ni1000
sensor
- Conversion of linear resistance variation to a standard analogue current signal,
for instance from valves or Ohmic level sensors.
Technical characteristics:
- within a few seconds the user can program the INT5333 to measure temperatures
with all RTD ranges defined by the standards.
- The RTD and resistance inputs have cable compensation for 2- and 3-wire
connection.
Mounting/Installation:
- For DIN form B sensor head or DIN rail mounting with a special fitting.
206
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order information:
Type Version
INT5333 Standard: :A
EEx: :B
FM and EEx: :C
Electrical specifications:
Specification range:
-40…+85 °C
Common specifications:
Supply voltage, DC
Standard, INT5333A 8…35 V
EEx and FM, INT5333B and C 8…28 V DC
Internal consumption 35 mW…0,8 W
Voltage drop 8 V DC
Warm-up time 5 min.
Communications interface Loop Link 5905
Signal/noise ratio min. 60 dB
Response time (programmable) 0,33…60 s
Signal dynamics, input 19 bit
Signal dynamics, output 19 bit
Calibration temperature 20…28 °C
Accuracy, the greater of general and basic values:
General values
Input type: Absolute accuracy Temperature coefficient
all d± 0,1 % of span d± 0,1 % of span / °C
Basic values
Input type: Basic accuracy Temperature coefficient
RTD d± 0,3 °C d± 0,01 °C / °C
Lin. R. dȍ dȍ&
207
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Output:
Current output:
Signal range 4…20 mA
Min signal range 16 mA
Updating time 135 ms
Load resistance d (Vsupply>ȍ@
Load stability RIVSDQȍ
Ex data:
Ui 28 V DC
Ii 120 mA DC
Pi 0,84 W
Li d 10 μH
Ci d 1 nF
208
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Resistance transmitter
Type: TMT84
Head transmitter with Profibus-PA££ interface. Supply and digital communication using
PROFIBUS-PA£ £, for installation in a form B sensor head.
Application areas:
- Applied in a PROFIBUS-PA£ environment, the process industry fieldbus, an open standard to
EN50170 and IEC 61158-2
- Temperature head transmitter with PROFIBUS-PA£ protocol for converting various input signals
into a ditigal output signal
- Input:
- Resistance thermometer (RTD)
- Thermocouple (TC)
5HVLVWDQFHWUDQVPLWWHUȍ
- Voltage transmitter (mV)
- Swift and easy operation, visualization and maintenance using a PC direct from the control panel,
e.g. using the COMMUWIN II operation software.
209
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
More detailed information for detailed project planning can be found in the operating manual.
Input values
Measurement value: Temperature (temperature linear), resistance and voltage
Measurement range: Dependent on the sensor connection and input signal the transmitter
evaluates a number of different measurement ranges.
Type of input:
210
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Output values
Output signal
Physical data transmission (Physical layer type):
Fieldbus interface in acc. to IEC 61158-2.
Failure signal
Status message acc. to the PROFIBUS-PA£ profile V3.0 specification.
Galvanic isolation
2 kV AC
Filter
Digital filter 1st degree 0...60 s
Current consumption
10 mA r 1 mA
Error current
0 mA
Switch on delay
- 10 s
Signal code
Manchester II
Auxiliary energy
Electrical connection
Power supply
Ub = 9...30 V DC non Ex area, polarity protected
Ub = 9...15 V DC Ex area, polarity protected
211
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Accuracy
Response time: 1s
Influence of reference Pt100 DIN IEC 751 Cl. B (internal reference junction for thermocouples)
junction:
- installation area:
connection head acc. to DIN 43729 Form B; field housing TAF 10
Condensation: allowable
212
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Mechanical construction
Dimensions:
Weight: approx. 40 g
Material: - housing: PC
- potting: PUR
Remote operation
Operation via PROFIBUS-PA£ using a suitable configuration or operating software.
Certification
Ex-certification
Details regarding the availability of the Ex-versions (ATEX, FM, CSA etc.) can be obtained from your
local sales organization. All relevant data for hazardous area protection can be found in separate Ex-
documentation, which can be requested separately.
CE marking
The measurement system complies with the legal requirements laid out within the EU regulations.
213
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Code Description
TMT84 Head Transmitter
Temperature transmitter with 2 sensor inputs and enhanced diagnosis functions for sensor monitoring.
PROFIBUS-PA£ protocol profile 3.01; Galvanic isolation 2 kV (input/output)
$SSOLFDWLRQ57'7&ȍDQG09&RQVXPWLRQPD[P$,QVWDOODWLRQFRQQHFWLRQKHDGIRU%
acc. to DIN 43729; UL listed, CSA general purpose
Approvals / Certifications:
A1 ex-free area
B1 ATEX II 1G Ex ia IIC T4/T5/T6
B2 ATEX II 3G Ex nA IIC T4/T5/T6
B3 ATEX II 3D
B4 ATEX II 1G Ex ia IIC T6, II 3D
B5 ATEX II 3G Ex nA IIC T6, II 3D
CA FM+CSA IS, NI I/1+2/ABCD
C1 FM IS, NI I/1+2/ABCD
C2 CSA IS, NI I/1+2/ABCD
D1 NEPSI Ex ia IIC T4/T5/T6
D2 TIIS Ex ia IIC T6
E1 IECEx Ex ia IIC T4/T5/T6
Communication, output signal
A PROFIBUS-PA£
Electrical connection
1 Spring terminals
2 Screw terminals
9 Special version, please specify
Mounting parts
A Standard-DIN mounting set
B US-M4 mounting screws
TMT84 <== Ordering code [part 1] - 1 option each category has to be chosen
Configuration input:
A1 Ch1: RTD 2-wire, Ch2: not active
A2 Ch1: RTD 2-wire, Ch2: RTD 2-wire
A3 Ch1: RTD 2-wire, Ch2: RTD 3-wire
A4 Ch1: RTD 2-wire, Ch2: TC
B1 Ch1: RTD 3-wire, Ch2: not active
B2 Ch1: RTD 3-wire, Ch2: RTD 2-wire
B3 Ch1: RTD 3-wire, Ch2: RTD 3-wire
B4 Ch1: RTD 3-wire, Ch2: TC
C1 Ch1: RTD 4-wire, Ch2: not active
C2 Ch1: RTD 4-wire, Ch2: TC
D1 Ch1: TC, Ch2: not active
D2 Ch1: TC, Ch2: TC
Display + Operation
E1 meas. Value indication & dip switch, attachable (TID10)
Calibration + Test
F1 Works calibration cert. 6-point (fixed points)
Tagging
X1 TAG, field bus
X2 TAG, paper (3 lines, each 16 characters)
X3 TAG, metal (2 lines, each 16 characters)
X4 Bus address (PA: 0…126)
X5 TAG on transmitter
TMT84
214
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
RTD Pt50, GOST Ni100, DIN 43760 RTD Pt50, GOST Ni100, DIN 43760
Pt100, IEC751 Ni120, Edison Curve Pt100, IEC751 Ni120, Edison Curve
Pt100, JIS C1604-81 Ni1000, DIN 43760 Pt100, JIS C1604-81 Ni1000, DIN 43760
Pt100, GOST Pt100, GOST
Pt200, IEC 751 Cu10 Edison Curve no. 15 Pt200, IEC 751 Cu10 Edison Curve no. 15
Pt500, IEC 751 Cu50, GOST Pt500, IEC 751 Cu50, GOST
Pt1000, IEC 751 Cu100, GOST Pt1000, IEC 751 Cu100, GOST
TC B E J K TC B E J K
IEC584 IEC584
N R S T N R S T
Unit
°C °F
Interconnection*
215
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Code Description
Switches
mag. switch type 1690, 3 m cable
S10 Protection class: IP68, max. operation temperature: 120°C
(Art.-No. 641.6502.380LI)
mag. switch type 1690 ATEX , 3 m cable
S20 Protection class: IP67 BVS03 ATEX, max. operation temperature 120°C
(Art.-Nr. 610.045N1001)
SXK Cable length > 3 m, each additional m (please specify)
SXS Hose clamp for switch 1690 and 1690 ATEX
Mag. switch type LMS-A
S30
Protection class IP65, max. operation temperature: 200°C (without special equipment)
S3G Mag. switch type LMS-A with gold plated contacts 8 VDC
S3D Mag. switch type LMS-A mounted in EExd housing
S3E Mag. switch type LMS-A with gold plated contacts 8 VDC
S40 Mag. switch type: LMS-AH
S4G Mag. switch type LMS-AH with gold plated contacts 8 VDC
S4D Mag. switch type LMS-AH mounted in EExd housing
Mag. switch type LMS-AH with gold plated contacts 8 VDC
S4E
+ mounted in Eexd housing
Mag. switch type NI-EX with P&F proximation initiator acc. NAMUR
S50
Protection class IP65 EExia ATEX, max. operation temperature: 60 °C
Mag. switch type NI-EX with P&F proximation initiator acc. NAMUR
S5H
with additional heat protection, max. operation temperature: 400 °C
Switch type MS9, with micro switch and additional heat protection
S6H
max. operation temperature: 400°C
Switch type MS10, with micro switch
S70 Protection class IP65, max. operation temperature: 200°C, max. 250 VAC/10A
mounted in Eexd housing
Switch type MS10, with micro switch with additional heat protection
S7H Protection class IP65, max. operation temperature: 400°C, max. 250 VAC/10A
mounted in Eexd housing
S80 Switch type MAK 9924
Cable entry for switch (all switches, except 1690/1690ATEX)
1 M20 x 1,5
2 1/2" NPT
3 3/4" NPT
Isolation amplifier for NI-EX switch
T01 Isolation amplifier for NI-EX switch; type: KFAG-SR2-EX1.W; one channel
T02 Isolation amplifier for NI-EX switch; type: KFAG-SR2-EX2.W; two channels
216
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Code Description
Reed chain
R05 Reed chain, resolution 5 mm, base price
L add. price each 100 mm
0 without heat protection
H with heat protection, max 400 °C / each 100 mm
R10 Reed chain, resolution 10 mm, max. 150 °C, base price
L add. price each 100 mm
0 without heat protection
H with heat protection, max 400 °C / each 100 mm
R20 Reed chain, resolution 20 mm, base price
L add. price each 100 mm
0 without heat protection
H with heat protection, max 400 °C / each 100 mm
RXS Clamps for reed chain / 2 pcs.
Transmitter
M10 Transmitter type: INT5333A
M11 Transmitter type: INT5333A with ExD-housing
M12 Transmitter type: INT5333A with stainless steel housing
M20 Transmitter type: INT5333B EX intrinsically safe
M22 Transmitter type: INT5333B EX intrinsically safe with stainless steel housing
M30 Transmitter type: INT5335A SMART/HART-technology
Transmitter type: INT5335B Ex-proof with SMART/HART-technology
M32
with stainless steel housing
M33 Transmitter type: INT5350B with Foundation Fieldbus
M35 Transmitter type: INT5350B with Foundation Fieldbus; EExia ATEX
M34 Transmitter type: TMT142 with Foundation Fieldbus and digital indicator
0 without Ex-protection
1 EExia ATEX
Transmitter type STT 3000 with digital indicator
M36
electr. Class EExd; output 4…20 mA
Cable entry for transmitter housings
1 M20 x 1,5
2 1/2" NPT
3 3/4" NPT
Digital indicator
Digital indicator mounted in transmitter housing (only with reed-chain)
D10
DSM-40-indicator, standard version input 4-20 mA; display ± 19999
Digital indicator mounted in transmitter housing (only with reed-chain)
D11
DSM-40-indicator, standard version input 4-20 mA; display ± 19999; EEx-version
D20 Digital indicator IA-N24-S, input 4-20 mA; 24 VDC for 2-wire-transmitters
Digital indicator IA-N30U, input 4-20 mA; 24 VDC for 2-wire-transmitters
D21
add. 4-20 mA-output
Digital indicator IA-N30U, input 4-20 mA; 24 VDC for 2-wire-transmitters
D22
add- 2 off. contacts
Digital indicator IA-N30U, input 4-20 mA; 24 VDC for 2-wire-transmitters
D23
add. 2 off contacs and 4-20 mA-output
217
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Code Description
Electronic heat tape
Electronic heat tape without Ex-protection, base price
H10
add. price each 100 mm
H11 Electronic heat tape connection set
H12 Electronic heat tape connection socket, material CS
Electronic heat tape, Ex-version
H20
add. price each 100 mm
H21 Electronic heat tape connection set Ex-version
H22 Electronic heat tape connection socket, material CS / EExd housing
H23 Electronic heat tape thermostat Ex-version
H30 Electronic heat tape for high temperature applications (> 200 °C)
H31 Electronic heat tape for high temperature applications (> 200 °C), Ex-Version
Power supply
SG1 Power supply 220 V / 50 Hz
Indication rail
Aluminium indication rail coated (Epoxy-coat: Saekaphen); colour: white
Z01
add. price each 100 mm
Measuring scale
Graduated scale, graved, material: 316SS, base price
Z02
add. price each 100 mm:
Graduated scale, graved, material: Aluminium, base price
Z02
add. price each 100 mm:
Steam jacket
Steam jacket, max. 6 bar, threaded connection, material 1.4404 (only available with
Z05
add. price each 100 mm:
Steam jacket, max. 6 bar, flanged connection DN 15 PN 16 (1/2" 150#),
Z06
add. price each 100 mm:
Vent/drain fittings
Z07 Vent-/drain valve 1/2" NPT / material 1.4401
Z08 Vent-/drain valve 1/2" NPT / material PTFE
Z09 Vent-/drain valve 1/2" NPT / material PP
Z10 Vent-/drain valve 1/2" NPT / material PVDF
Z11 Vent-/drain ball valve 1/2" NPT / material 1.4401
Z12 Vent-/drain valve 1/2" NPT, einseitig geflanscht mit DN 15 PN 16
Z13 Vent-/drain valve 1/2" NPT / material: 1.4401
Insulation
Low-temperature-insulation Armaflex -75...+105 °C (only available with Aluminium-
Z14
indication rail and Titanium float) (each 100 mm)
Z15 Low-temperature-insulation with mineral wool with 316SS arming (each 100 mm)
Heat insulation ceramic tape; op. temperature up to 600 °C (only available with
Z16
Aluminium-indication rail and Titanium float) (each 100 mm)
Insulation guide plate*, material 1.4404; height = 80 mm Equipment for Armaflex- or
Z17
ceramic insulation (each 100 mm)
Z18 Makrolon window for insulation (each 100 mm)
218
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Code Description
Painting
Z19 Device completely painted with RAL-colour (grounding + main paint)
Aluminium grey RAL 9007 (80°C)
Z20
with Hempel's Silicone Aluminium 56910 (600°C)
ZPY other paintings
Security Springs
Z21 spring at top of gauge
Z22 spring at bottom of gauge
219
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Code Description
ITA-3 BV Bureau Veritas
ITA-6 BV Bureau Veritas
ITA-3 GL Design for maritime and inland navigation acc. rules of "German Lloyd"
(Individual Acceptance Test)
ITA-6 GL Design for maritime and inland navigation acc. rules of "German Lloyd"
(Individual Acceptance Test)
ITA-3 LR Lloyd's Register
ITA-6 LR Lloyd's Register
ITA-6 D Design as steam regulator acc. TRD incl. 2 switches type: LMS-AH
ITA-7-D Design as steam regulator acc. TRD incl. 2 switches type: LMS-AH
ITA-3 / 3.0 Ex
ITA-4 /4.0 Ex Design for Ex-zone 0 (following 94/9/EG: II 1 Gc IIC T1...T6)
ITA-4.1 / 4.1.0 Ex
ITA-5 / 5.0 Ex According to the "Statement of application for directive 94/9/EC", issued by
"TÜV Industrie Service GmbH" (notified body), the directive 94/9/EC is
ITA-6 / 6.0 Ex
not applicable for ITA mag. level gauges, as they have no ignition sources
ITA-7 / 7.0 Ex of their own. So the level gauge can be used in Ex-zone 0 without being
ITA-10 / 10.0 Ex certified, once the technical specifications described in the statement have
ITA-11 / 11.0 Ex have been followed.
ITA-12 / 12.0 Ex
220
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
Floats for ITA-3 and ITA-3.0 (PN16/150 lbs)
3V0100K1 16 316SS 52 125 1,4907 N
3V0100K3 16 316SS 52 125 1,0524 N only with 316SS or Aluminium indication rail
3V0120K1 16 316SS 52 145 1,2346 N
3V0120K3 16 316SS 52 145 0,9034 N only with 316SS or Aluminium indication rail
3V0150K1 16 316SS 52 175 0,9905 N
3V0150K3 16 316SS 52 175 0,8606 N only with 316SS or Aluminium indication rail
3V0180K1 16 316SS 52 205 0,8781 N
3V0180K3 16 316SS 52 205 0,7022 N only with 316SS or Aluminium indication rail
3V0240K1 16 316SS 52 265 0,7374 N
3V0240K3 16 316SS 52 265 0,6209 N only with 316SS or Aluminium indication rail
3V1240K1 40 316SS 52 265 1,000 N
3T0100K1 16 Titanium 50,8 125 1,1788 N do not use with hydrogen or alcohol compounds
3T0100K3 16 Titanium 50,8 125 0,7821 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0120K1 16 Titanium 50,8 145 0,9646 N do not use with hydrogen or alcohol compounds
3T0120K3 16 Titanium 50,8 145 0,6514 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0150K1 16 Titanium 50,8 175 0,7763 N do not use with hydrogen or alcohol compounds
3T0150K3 16 Titanium 50,8 175 0,5675 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0180K1 16 Titanium 50,8 205 0,6716 N do not use with hydrogen or alcohol compounds
3T0180K3 16 Titanium 50,8 205 0,5094 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0240K1 16 Titanium 50,8 265 0,5723 N do not use with hydrogen or alcohol compounds
3T0240K3 16 Titanium 50,8 265 0,4550 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0300K1 16 Titanium 50,8 325 0,4955 N do not use with hydrogen or alcohol compounds
3T0300K3 16 Titanium 50,8 325 0,4063 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0400K1 16 Titanium 50,8 425 0,4358 N do not use with hydrogen or alcohol compounds
3T0400K3 16 Titanium 50,8 425 0,3719 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0500K1 16 Titanium 50,8 525 0,4017 N do not use with hydrogen or alcohol compounds
3T0500K3 16 Titanium 50,8 525 0,3539 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0600K1 16 Titanium 50,8 625 0,3761 N do not use with hydrogen or alcohol compounds
3T0600K3 16 Titanium 50,8 625 0,3371 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3H0150K1 16 Titanium, 52 175 0,9020 N
Halar-coated
3HC012K1 16 Hastelloy C4 52 175 1,2455 N
3HC024K1 16 Hastelloy C4 52 265 0,7510 N
3HC024K3 16 Hastelloy C4 52 265 0,6296 N only with 316SS or Aluminium indication rail
Floats for ITA-3 Cryo (PN16/150 lbs, for cryogenic applications)
3C0240K1 16 Titanium 50,8 265 0,5723 N without spacers;
do not use for hydrogen or alcohol compounds
3C0500K1 16 Titanium 45 525 0,5509 N with spacers;
do not use for hydrogen or alcohol compounds
3C0500K3 16 Titanium 45 525 0,5038 N with spacers;
only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
221
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
Floats for ITA-3-CR64 and ITA-3.0-CR64 (PN16/150 lbs, for cryogenic applications)
3C0501K1 16 Titanium 50,8 525 0,4017 N with spacers;
do not use for hydrogen or alcohol compounds
3C0501K2 16 Titanium 50,8 525 0,3890 N with spacers;
do not use for hydrogen or alcohol compounds
Floats for ITA-3.5 (PN16/150 lbs, wetted parts E-CTFE (Halar)-coated)
35H024K1 16 Titanium, 52 240 0,6873 N
Halar-coated
35H024K3 16 Titanium, 52 240 0,5645 N only with 316SS or Aluminium indication rail
Halar-coated
Floats for ITA-3.8 (PN16/150 lbs, wetted parts E-CTFE (Halar)-coated, applicable for vacuum-service)
34PVD1K1 10 E-TFE 50 135 1,3000 N
34PVD2K1 10 E-TFE 50 255 0,8500 N
34GLA2K2 10 Borosilicate 50 255 0,8500 N
Floats for ITA-4 and ITA-4.0 (PN16/150 lbs, top-of tank mounting)
[max. Rod length: A = 500 mm; B = 750 mm; C = 1000 mm; D = 1250 mm; E = 1500 mm; F = 1750 mm; H = 2000]
4V0240R1A 16 316L 52,0 265 0,9500 N
4V0240R1B 16 316L 52,0 265 1,0000 N
4T0240R1A 16 Titanium 50,8 265 0,6890 N do not use with hydrogen or alcohol compounds
4T0240R1B 16 Titanium 50,8 265 0,7250 N do not use with hydrogen or alcohol compounds
4T0240R1C 16 Titanium 50,8 265 0,7610 N do not use with hydrogen or alcohol compounds
4T0240R1D 16 Titanium 50,8 265 0,7970 N do not use with hydrogen or alcohol compounds
4T0240R1E 16 Titanium 50,8 265 0,8330 N do not use with hydrogen or alcohol compounds
4T0240R1F 16 Titanium 50,8 265 0,8690 N do not use with hydrogen or alcohol compounds
4T0240R1H 16 Titanium 50,8 265 0,9050 N do not use with hydrogen or alcohol compounds
4T0240K2A 16 Titanium 50,8 265 0,6480 N do not use with hydrogen or alcohol compounds
4T0240K2B 16 Titanium 50,8 265 0,6840 N do not use with hydrogen or alcohol compounds
4T0240K2C 16 Titanium 50,8 265 0,7200 N do not use with hydrogen or alcohol compounds
4T0240K2D 16 Titanium 50,8 265 0,7560 N do not use with hydrogen or alcohol compounds
4T0240K2E 16 Titanium 50,8 265 0,7920 N do not use with hydrogen or alcohol compounds
4T0240K2F 16 Titanium 50,8 265 0,8280 N do not use with hydrogen or alcohol compounds
4T0240K2H 16 Titanium 50,8 265 0,8640 N do not use with hydrogen or alcohol compounds
4T0240K3A 16 Titanium 50,8 265 0,5820 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3B 16 Titanium 50,8 265 0,6810 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3C 16 Titanium 50,8 265 0,6540 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3D 16 Titanium 50,8 265 0,6900 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3E 16 Titanium 50,8 265 0,7260 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3F 16 Titanium 50,8 265 0,7620 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3H 16 Titanium 50,8 265 0,7980 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300R1A 16 Titanium 50,8 325 0,6010 N do not use with hydrogen or alcohol compounds
4T0300R1B 16 Titanium 50,8 325 0,6290 N do not use with hydrogen or alcohol compounds
4T0300R1C 16 Titanium 50,8 325 0,6580 N do not use with hydrogen or alcohol compounds
4T0300R1D 16 Titanium 50,8 325 0,6870 N do not use with hydrogen or alcohol compounds
4T0300R1E 16 Titanium 50,8 325 0,7160 N do not use with hydrogen or alcohol compounds
4T0300R1F 16 Titanium 50,8 325 0,7450 N do not use with hydrogen or alcohol compounds
4T0300R1H 16 Titanium 50,8 325 0,7730 N do not use with hydrogen or alcohol compounds
222
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
Floats for ITA-4 and ITA-4.0 (PN16/150 lbs, top-of tank mounting) (Continuation)
[max. Rod length: A = 500 mm; B = 750 mm; C = 1000 mm; D = 1250 mm; E = 1500 mm; F = 1750 mm; H = 2000]
4T0300K2A 16 Titanium 50,8 325 0,5680 N do not use with hydrogen or alcohol compounds
4T0300K2B 16 Titanium 50,8 325 0,5970 N do not use with hydrogen or alcohol compounds
4T0300K2C 16 Titanium 50,8 325 0,6250 N do not use with hydrogen or alcohol compounds
4T0300K2D 16 Titanium 50,8 325 0,6540 N do not use with hydrogen or alcohol compounds
4T0300K2E 16 Titanium 50,8 325 0,6830 N do not use with hydrogen or alcohol compounds
4T0300K2F 16 Titanium 50,8 325 0,7120 N do not use with hydrogen or alcohol compounds
4T0300K2H 16 Titanium 50,8 325 0,7410 N do not use with hydrogen or alcohol compounds
4T0300K3A 16 Titanium 50,8 325 0,5120 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3B 16 Titanium 50,8 325 0,5410 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3C 16 Titanium 50,8 325 0,5690 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3D 16 Titanium 50,8 325 0,5980 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3E 16 Titanium 50,8 325 0,6270 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3F 16 Titanium 50,8 325 0,6560 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3H 16 Titanium 50,8 325 0,6850 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
Floats for ITA-4.1 and ITA-4.1.0 (atm., top-of tank mounting)
[max. Rod length: A = 500 mm; B = 750 mm; C = 1000 mm; D = 1250 mm; E = 1500 mm; F = 1750 mm; H = 2000]
4T0152R1A ATM Titanium 80 175 0,4070 N do not use with hydrogen or alcohol compounds
4T0152R1B ATM Titanium 80 175 0,4310 N do not use with hydrogen or alcohol compounds
4T0152R1C ATM Titanium 80 175 0,4540 N do not use with hydrogen or alcohol compounds
4T0152R1D ATM Titanium 80 175 0,4770 N do not use with hydrogen or alcohol compounds
4T0152R1E ATM Titanium 80 175 0,5000 N do not use with hydrogen or alcohol compounds
4T0152R1F ATM Titanium 80 175 0,5240 N do not use with hydrogen or alcohol compounds
4T0152R1H ATM Titanium 80 175 0,5470 N do not use with hydrogen or alcohol compounds
4T0152K2A ATM Titanium 80 175 0,4700 N do not use with hydrogen or alcohol compounds
4T0152K2B ATM Titanium 80 175 0,4310 N do not use with hydrogen or alcohol compounds
4T0152K2C ATM Titanium 80 175 0,4540 N do not use with hydrogen or alcohol compounds
4T0152K2D ATM Titanium 80 175 0,4770 N do not use with hydrogen or alcohol compounds
4T0152K2E ATM Titanium 80 175 0,5000 N do not use with hydrogen or alcohol compounds
4T0152K2F ATM Titanium 80 175 0,5240 N do not use with hydrogen or alcohol compounds
4T0152K2H ATM Titanium 80 175 0,5470 N do not use with hydrogen or alcohol compounds
4T0152K3A ATM Titanium 80 175 0,4710 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3B ATM Titanium 80 175 0,4940 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3C ATM Titanium 80 175 0,5180 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3D ATM Titanium 80 175 0,5410 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3E ATM Titanium 80 175 0,5640 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3F ATM Titanium 80 175 0,6870 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3H ATM Titanium 80 175 0,6100 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
223
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
Floats for ITA-4.1 and ITA-4.1.0 (atm., top-of tank mounting) / Continuation
[max. Rod length: A = 500 mm; B = 750 mm; C = 1000 mm; D = 1250 mm; E = 1500 mm; F = 1750 mm; H = 2000]
4T0182R1A ATM Titanium 80 205 0,3620 N do not use with hydrogen or alcohol compounds
4T0182R1B ATM Titanium 80 205 0,3810 N do not use with hydrogen or alcohol compounds
4T0182R1C ATM Titanium 80 205 0,4000 N do not use with hydrogen or alcohol compounds
4T0182R1D ATM Titanium 80 205 0,4200 N do not use with hydrogen or alcohol compounds
4T0182R1E ATM Titanium 80 205 0,4390 N do not use with hydrogen or alcohol compounds
4T0182R1F ATM Titanium 80 205 0,4580 N do not use with hydrogen or alcohol compounds
4T0182R1H ATM Titanium 80 205 0,4780 N do not use with hydrogen or alcohol compounds
4T0182K2A ATM Titanium 80 205 0,3370 N do not use with hydrogen or alcohol compounds
4T0182K2B ATM Titanium 80 205 0,3570 N do not use with hydrogen or alcohol compounds
4T0182K2C ATM Titanium 80 205 0,3760 N do not use with hydrogen or alcohol compounds
4T0182K2D ATM Titanium 80 205 0,3950 N do not use with hydrogen or alcohol compounds
4T0182K2E ATM Titanium 80 205 0,4150 N do not use with hydrogen or alcohol compounds
4T0182K2F ATM Titanium 80 205 0,3430 N do not use with hydrogen or alcohol compounds
4T0182K2H ATM Titanium 80 205 0,4530 N do not use with hydrogen or alcohol compounds
4T0182K3A ATM Titanium 80 205 0,3000 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3B ATM Titanium 80 205 0,3190 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3C ATM Titanium 80 205 0,3380 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3D ATM Titanium 80 205 0,3580 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3E ATM Titanium 80 205 0,3770 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3F ATM Titanium 80 205 0,3960 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3H ATM Titanium 80 205 0,4160 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242R1A ATM Titanium 80 265 0,2980 N do not use with hydrogen or alcohol compounds
4T0242R1B ATM Titanium 80 265 0,3120 N do not use with hydrogen or alcohol compounds
4T0242R1C ATM Titanium 80 265 0,3270 N do not use with hydrogen or alcohol compounds
4T0242R1D ATM Titanium 80 265 0,3410 N do not use with hydrogen or alcohol compounds
4T0242R1E ATM Titanium 80 265 0,3560 N do not use with hydrogen or alcohol compounds
4T0242R1F ATM Titanium 80 265 0,3700 N do not use with hydrogen or alcohol compounds
4T0242R1H ATM Titanium 80 265 0,3850 N do not use with hydrogen or alcohol compounds
4T0242K2A ATM Titanium 80 265 0,2800 N do not use with hydrogen or alcohol compounds
4T0242K2B ATM Titanium 80 265 0,2940 N do not use with hydrogen or alcohol compounds
4T0242K2C ATM Titanium 80 265 0,3090 N do not use with hydrogen or alcohol compounds
4T0242K2D ATM Titanium 80 265 0,3230 N do not use with hydrogen or alcohol compounds
4T0242K2E ATM Titanium 80 265 0,3880 N do not use with hydrogen or alcohol compounds
4T0242K2F ATM Titanium 80 265 0,3520 N do not use with hydrogen or alcohol compounds
4T0242K2H ATM Titanium 80 265 0,3670 N do not use with hydrogen or alcohol compounds
4T0242K3A ATM Titanium 80 265 0,2530 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3B ATM Titanium 80 265 0,2680 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3C ATM Titanium 80 265 0,2820 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3D ATM Titanium 80 265 0,2970 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3E ATM Titanium 80 265 0,3110 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3F ATM Titanium 80 265 0,3260 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3H ATM Titanium 80 265 0,3400 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
224
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
Floats for ITA-5 (top-bottom connection)
Please see ITA-3 to ITA-13
Floats for ITA-6 and ITA-6.0 (PN40/300 lbs)
6V0100K1 30 316L 52 125 1,5188 N
6V0100K3 30 316L 52 125 1,0891 N only with 316SS or Aluminium indication rail
6V0120K1 30 316L 52 145 1,2780 N
6V0120K3 30 316L 52 145 0,9519 N only with 316SS or Aluminium indication rail
6V0150K1 30 316L 52 175 1,0711 N
6V0150K3 30 316L 52 175 0,8309 N only with 316SS or Aluminium indication rail
6V0180K1 30 316L 52 205 0,9486 N
6V0180K3 30 316L 52 205 0,8140 N only with 316SS or Aluminium indication rail
6V0240K1 30 316L 52 265 0,7738 N
6V0240K3 30 316L 52 265 0,6513 N only with 316SS or Aluminium indication rail
6T0100K1 40 Titanium 50,8 125 1,3114 N do not use with hydrogen or alcohol compounds
6T0100K3 40 Titanium 50,8 125 0,8975 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
6T0120K1 40 Titanium 50,8 145 1,1007 N do not use with hydrogen or alcohol compounds
6T0120K3 40 Titanium 50,8 145 0,7837 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
6T0150K1 40 Titanium 50,8 175 0,9029 N do not use with hydrogen or alcohol compounds
6T0150K3 40 Titanium 50,8 175 0,6763 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
6T0180K1 40 Titanium 50,8 205 0,7791 N do not use with hydrogen or alcohol compounds
6T0180K3 40 Titanium 50,8 205 0,6100 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
6T0240K1 40 Titanium 50,8 265 0,6391 N do not use with hydrogen or alcohol compounds
6T0240K3 40 Titanium 50,8 265 0,5187 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
6T0300K1 40 Titanium 50,8 325 0,5694 N do not use with hydrogen or alcohol compounds
6T0300K3 40 Titanium 50,8 325 0,4812 N do not use with hydrogen or alcohol compounds
6T0400K1 40 Titanium 50,8 425 0,5300 N do not use with hydrogen or alcohol compounds
6T0400K3 40 Titanium 50,8 425 0,4373 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
6T0500K1 40 Titanium 50,8 525 0,4463 N do not use with hydrogen or alcohol compounds
6T0500K3 40 Titanium 50,8 525 0,4098 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
6T0600K1 40 Titanium 50,8 625 0,4370 N do not use with hydrogen or alcohol compounds
6T0600K3 40 Titanium 50,8 625 0,3834 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
6H0200K1 40 Titanium, 52 265 0,7674 N
Halar-coated
6H0200K3 40 Titanium, 52 265 0,6470 N only with 316SS or Aluminium indication rail
Halar-coated
6HC012K1 40 Hastelloy C4 52 145 1,2400 N
6HC024K1 40 Hastelloy C4 52 265 0,7470 N
6HC024K3 40 Hastelloy C4 52 265 0,6600 N only with 316SS or Aluminium indication rail
Floats for ITA-6 Cryo and ITA-6.0 Cryo (PN40/300 lbs; cryogenic applications)
6C0240K1 40 Titanium 50,8 265 0,6391 N without spacers
do not use with hydrogen or alcohol compounds
6C0500K1 40 Titanium 45 525 0,5981 N with spacers
do not use with hydrogen or alcohol compounds
6HC024K3 24 Hastelloy C4 52 265 0,66 N with spacers, only with Aluminium or SS indication rail
Floats for ITA-6-CR64 and ITA-6.0-CR64 (PN40/300 lbs; cryogenic applications)
6C0240K1 40 Titanium 50,8 265 0,6391 N with spacers
do not use with hydrogen or alcohol compounds
6C0501K1 40 Titanium 45 525 0,5981 N with spacers, only with Aluminium or SS indication rail
do not use with hydrogen or alcohol compounds
225
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
Floats for ITA-7 and ITA-7.0 (PN64/300 lbs)
7T0240K1 64 Titanium 50,8 265 0,6820 N do not use with hydrogen or alcohol compounds
7T0240K3 64 Titanium 50,8 265 0,5551 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
7T0300K1 64 Titanium 50,8 325 0,6064 N do not use with hydrogen or alcohol compounds
7T0300K3 64 Titanium 50,8 325 0,5168 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
7T0500K3 64 Titanium 50,8 525 0,4450 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
7T0600K3 64 Titanium 50,8 625 0,4243 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
Floats for ITA-8.1 (PN6; PVC)
8PVC01K1 10 PVC 50 135 1,1500 N only with 316SS or Aluminium indication rail
8PVC02K1 10 PVC 50 255 0,7500 N only with 316SS or Aluminium indication rail
Floats for ITA-8.2 (PN6; PP)
8PVC01K1 10 PP 50 135 0,9500 N only with 316SS or Aluminium indication rail
8PVC02K1 10 PP 50 255 0,6500 N only with 316SS or Aluminium indication rail
Floats for ITA-8.3 (PN6; PVDF)
8PVC01K1 10 PVDF 50 135 1,3000 N only with 316SS or Aluminium indication rail
8PVC02K1 10 PVDF 50 255 0,8500 N only with 316SS or Aluminium indication rail
Floats for ITA-9.1 (PN6; PVC; mounted from top of tank)
9PVC03K1 6 PVC 50 135 N only with 316SS or Aluminium indication rail
Floats for ITA-9.2 (PN6; PP; mounted from top of tank)
9PP030K1 6 PP 50 N only with 316SS or Aluminium indication rail
Floats for ITA-9.3 (PN6; PVDF; mounted from top of tank)
9PVD03K1 6 PP 50 N only with 316SS or Aluminium indication rail
Floats for ITA-10 and ITA-10.0 (PN100/600 lbs)
10V324K3 100 316L 52 265 0,6122 Y only with 316SS or Aluminium indication rail
10T024K1 80 Titanium 50,8 265 0,7011 N do not use for hydrogen or alcohol compounds
10T024K3 80 Titanium 50,8 265 0,5823 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T030K1 80 Titanium 50,8 325 0,6212 N do not use for hydrogen or alcohol compounds
10T030K3 80 Titanium 50,8 325 0,5275 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T040K1 80 Titanium 50,8 425 0,5515 N do not use for hydrogen or alcohol compounds
10T040K3 80 Titanium 50,8 425 0,4871 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T050K1 80 Titanium 50,8 525 0,5095 N do not use for hydrogen or alcohol compounds
10T050K3 80 Titanium 50,8 525 0,4574 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T060K1 80 Titanium 50,8 625 0,4632 N do not use for hydrogen or alcohol compounds
10T060K3 80 Titanium 50,8 625 0,4209 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T124K1 100 Titanium 50,8 265 0,8299 N do not use for hydrogen or alcohol compounds
10T124K3 100 Titanium 50,8 265 0,7006 N only with 316SS or Aluminium indication rail;
Float for high-temperature applications;
do not use for hydrogen or alcohol compounds
10T130K1 100 Titanium 50,8 325 0,7617 N do not use for hydrogen or alcohol compounds
10T130K3 100 Titanium 50,8 325 0,6594 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T140K1 100 Titanium 50,8 425 0,6779 N do not use for hydrogen or alcohol compounds
10T140K3 100 Titanium 50,8 425 0,6075 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T150K1 100 Titanium 50,8 525 0,6321 N do not use for hydrogen or alcohol compounds
10T150K3 100 Titanium 50,8 525 0,5775 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
226
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
Floats for ITA-11 and ITA-11.0 (PN160/1500 lbs)
11V324K2 160 316L 46 265 0,7736 Y
11T330K2 160 Titanium 46 325 0,4901 Y do not use for hydrogen or alcohol compounds
11T018K1 130 Titanium 45 205 1,0185 N do not use for hydrogen or alcohol compounds
11T018K3 130 Titanium 45 205 0,8455 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T024K1 130 Titanium 45 265 0,8600 N do not use for hydrogen or alcohol compounds
11T024K3 130 Titanium 45 265 0,7450 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T030K1 130 Titanium 45 325 0,7822 N do not use for hydrogen or alcohol compounds
11T030K3 130 Titanium 45 325 0,6949 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T040K1 130 Titanium 45 425 0,7028 N do not use for hydrogen or alcohol compounds
11T040K3 130 Titanium 45 425 0,6391 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T050K1 130 Titanium 45 525 0,6587 N do not use for hydrogen or alcohol compounds
11T050K3 150 Titanium 45 525 0,6106 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T124K3 150 Titanium 46 265 0,7324 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T130K3 150 Titanium 46 325 0,7042 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T140K3 150 Titanium 46 425 0,6164 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T150K3 150 Titanium 46 525 0,6008 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T218K1 160 Titanium 42 205 1,1692 N do not use for hydrogen or alcohol compounds
11T218K3 160 Titanium 42 205 0,9291 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T224K1 160 Titanium 42 265 0,9768 N do not use for hydrogen or alcohol compounds
11T224K3 160 Titanium 42 265 0,8120 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T230K1 160 Titanium 42 325 0,8871 N do not use for hydrogen or alcohol compounds
11T230K3 160 Titanium 42 325 0,7613 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T240K1 160 Titanium 42 425 0,7832 N do not use for hydrogen or alcohol compounds
11T240K3 160 Titanium 42 425 0,6934 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T250K1 160 Titanium 42 525 0,7268 N do not use for hydrogen or alcohol compounds
11T250K3 160 Titanium 42 525 0,6571 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
Floats for ITA-12 and ITA-12.0 (PN250/1500 lbs)
12V324K3 250 316L 46 265 0,7736 Y
12T324K3 250 Titanium 46 265 0,5526 Y only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T218K1 250 Titanium 42 205 1,2085 N do not use for hydrogen or alcohol compounds
12T218K3 250 Titanium 42 205 0,9659 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T224K1 250 Titanium 42 265 1,0396 N do not use for hydrogen or alcohol compounds
12T224K3 250 Titanium 42 265 0,9659 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T230K1 250 Titanium 42 325 0,9250 N do not use for hydrogen or alcohol compounds
12T230K3 250 Titanium 42 325 0,7978 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T240K1 250 Titanium 42 425 0,8304 N do not use for hydrogen or alcohol compounds
12T240K3 250 Titanium 42 425 0,7394 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
227
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
Floats for ITA-12 and ITA-12.0 (PN250/1500 lbs) (Continuation)
12T124K3 250 Titanium 38 265 0,8944 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T130K3 250 Titanium 38 325 0,8281 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T250K1 250 Titanium 42 525 0,7763 N do not use for hydrogen or alcohol compounds
12T250K3 250 Titanium 42 525 0,7055 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
Floats for ITA-13 and ITA-13.0 (PN320/2500 lbs)
13V330K3 320 316L 38 325 0,7269 Y only with 316SS or Aluminium indication rail
13T324K3 320 Titanium 38 265 0,5366 Y only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds
13T024K3 320 Titanium 38 265 0,8985 N only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds
13T330K3 320 Titanium 38 325 0,5032 Y only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds
13T040K3 320 Titanium 38 425 0,7582 N only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds
228
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
229
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
General Documentation
Code Description
D001 Certificate of Conformity
D003 Drawings for special types
D004 Certificate of origin
D005 Certificate of orign by German Chamber of Commerce
D006 Legalised by Embassy of recipient
D007 Standard QA-Plan
D008 Inspection certificate
D009 QA-Manual
D009a Calibration certificate
D009b Legalised by Embassy of recipient
Documents on CD
D009c only one manual or technical information
D009d up to 4 manuals or technical information
D009e manuals incl. e.g. 3.1B, drawings, cert. of conf. etc.
D009f add. documents as paper print
Orderwise Documentation
Code Description
D010 Production schedule
D011 Manufacturing Progress Status Report
D012 Test Procedures (Covering Manufacturing)
D013 Welding Procedures (WPS, PQR),
D014 Welding Procedures (WPS, PQR),
S i l i l
230
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Material certificates
Code Description
D015 Material Certificate EN 10204:2004-2.2
D016 Material certificates acc. EN 10204:2004-3.1, for ITA-3 to ITA-6, please
advise if cast marking for pressure retaining parts required
Cast marking of pressure retaining parts
D016a for special material (ITA3 to ITA-6)
Cast marking of pressure retaining parts
D017 Material certificates acc. EN 10204:2004-3.1, for ITA-7 to ITA-13,
please advise if cast marking for pressure retaining parts required
Cast marking of pressure retaining parts
D017a for special material (ITA7 to ITA-13)
Cast marking of pressure retaining parts
D018 Material certificates acc. EN 10204:2004-3.2 (former 3.1C or 3.1A)
Code Description
D019 Category sound engineering paractice manufactured and tested acc. Module A1,
checked against diagram 1of PED 97/23/EG
D020 Category I,II und III manufactured and tested acc. Module H, checked against diagram
1of PED 97/23/EG
D022 Category IV manufactured and tested acc. Modul G. Layout test and inspection by
German TÜV
Code Description
D023 Hydr. pressure test incl. test certificate
D024 Inspection And Pressure Testing acc. AD-Merkblatt, TRB and TRD By
German TÜV, incl. Cast Marking and Certificates EN 10204 3.1B, for
Standard ITA
D025 Inspection And Pressure Testing acc. AD-Merkblatt, TRB and TRD By
German TÜV, incl. Cast Marking and Certificates EN 10204 3.1B, for
Special Constructed ITA
D026 Radiographic Examination Of Welds (Only Buttwelds) acc. DIN 54111
231
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Code Description
D027 Dyepenetrant Examination Of Welds acc.
EN473:2000 and PED
Code Description
D032 Standard wiring plans and data sheets
D033 ATEX-certificates
General notes:
232
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
5. Special Constructions
Introduction
Monitoring switches
233
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Interface Measuring
Very often dissimilar liquids resides in a tank. Most tank gauging methods
are limited in these cases and only indicate the level of the uppermost
surface. But, with using Intra-Automation level sensing elements, you can
easily monitor the interface between liquids. By adjusting the specific
gravity of the magnet float, Intra can adapt the transmitter to monitor the
interface of a broad range of media. This principle applies to oil and water,
slurries, acid, bilge and other dissimilar liquids.
In conjunction with DigiFlow 520 tank level, ITA-T1S will help assure that
only the “correct” liquid is taken from a tank, or introduced into a process
system.
234
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Float type
Transmitter
235
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Order key:
236
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Technical data
Max. operation pressure: 40 bar, depending on mounting type and float type
Max. temperature: 100 °C (213 °F)
Min. operation temperature: depending on the float type
Installation: vertical; ±30°
Protection class: IP65 (NEMA 4)
Weight: depending on version
Min. switch distance: float diameter + 30 mm
Dimensions:
L1: min. 30 mm (flanged version)
min. 50 mm (threaded version)
Lmax: 3000 mm
237
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
Besides the products covered by this brochure, Intra-Automation GmbH also manufactures other high-
quality and high precision instruments for industrial measurement tasks. For more information, please
contact us (contact details on the backside of this brochure).
Flow Measurement
Cone Flowmeters
Itabar-Flow-Meters
Flow Nozzles
Level Measurement
Transparent type level gauge Reflex type level gauge Tubular type level gauge
Intra-Automation provides a wide range of measurement and control instruments. For more information, please
contact us visit our homepage www.intra-automation.com.
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation
+49-(0)2181-75665-0 +31-(0)165-322201
+49-(0)2181-64492 +31-(0)165-322970
[email protected] [email protected]