Magnetically Controlled Liquid Level Indicator

Type ITA
ITA with ITA with mA-Output and Digital Display ITA with Steam
Alumium- with Volume Linearization Jacket
Indication-Rail
and Switch

ITA with Inspection/Certificate ITA, material


Armaflex®- PVDF
Insulation
 Material certificate EN 10204 2.1
 Material certificate EN 10204 3.1
 Test acc. to NACE
 Pressure test certificate
 Pressure test acc to „AD-Merkblatt“ by German TUV
 Construction and pressure test as per TRD by German TUV
 Dye penetration test DIN 54152
 X-Ray test acc. with DIN 54111, part 1
 PMI-check
 ATEX-certificate
 General approval of construction inspection acc. with § 19
water resources law about flammable liquids-Vbf
 Water level controller component-check as per
VdTUV/WR91-352
 Germanischer Lloyd
 Certification of passivation
 Weight certificate

Technical Catalogue

THE EXPERT IN LEVEL AND FLOW


Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

List of Contents

1. ISO 9001-certificate 1

2. Functioning and General Information 2


2.1 Magnetically controlled liquid level gauge type ITA 2
2.2 Level measurement tasks 2
2.3 Advantages 3
2.4 Switches and alarm contacts 3
2.5 Floats 3
2.6 Indication rails 4
2.7 Materials 4
2.8 Special versions 4
2.9 Additional equipment 4
2.10 Acceptance tests and certificates 5

3. Level gauges in details 6


3.1.1 ITA-3 6
3.1.2 ITA-3.0 8
3.1.3 Pressure-Temperature Table ITA-3 (Float pipe) 10
3.1.4 Order codes for ITA-3 & ITA-3.0 11
3.2.1 ITA-3 Cryo (cryogenic applications) 19
3.2.2 Order codes for ITA-3 Cryo 21
3.3.1 ITA-3-CR64 (cryogenic applications) 28
3.3.2 Order codes for ITA-3 CR64 30
3.4.1 ITA-3.5 37
3.4.2 Order codes for ITA-3.5 39
3.5.1 ITA-3.8 44
3.5.2 Order codes for ITA-3.8 46
3.6.1 ITA-4 50
3.6.2 ITA-4.0 52
3.6.3 Order codes for ITA-4 & ITA-4.0 54
3.7.1 ITA-4.1 58
3.7.2 ITA-4.1.0 60
3.7.3 Order codes for ITA-4.1 & ITA-4.1.0 62
3.8.1 ITA-5 67
3.8.2 ITA-5.0 69
3.8.3 Oder codes for ITA-5 & ITA-5.0 71
3.9.1 ITA-6 76
3.9.2 ITA-6.0 78
3.9.3 Pressure-Temperature Table ITA-6 (Float pipe) 79
3.9.4 Order codes for ITA-6 & ITA-6.0 81
3.10.1 ITA-6 Cryo (cryogenic applications) 89
3.10.2 Order codes for ITA-6 Cryo 91
3.11.1 ITA-6 CR64 (cryogenic applications) 96
3.11.2 Order codes for ITA-6 CR64 98
3.12.1 ITA-7 103
3.12.2 ITA-7.0 105
3.12.3 Pressure-Temperature Table ITA-7 (Float pipe) 107
3.12.4 Order codes for ITA-7 & ITA-7.0 108
3.13.1 ITA-8.1 (PVC) 115
3.13.2 Order codes for ITA-8.1 117
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

List of Contents (continuation)

3.14.1 ITA-8.2 (PP) 120


3.14.2 Order codes for ITA-8.2 122
3.15.1 ITA-8.3 (PVDF) 125
3.15.3 Order codes for ITA-8.3 128
3.16.1 ITA-9.1 (PVC) 130
3.16.2 Order codes for ITA-9.1 132
3.17.1 ITA-9.2 (PP) 134
3.17.2 Order codes for ITA-9.2 136
3.18.1 ITA-9.3 (PVDF) 138
3.18.2 Order codes for ITA-9.3 140
3.19.1 ITA-10 142
3.19.2 ITA-10.0 144
3.19.3 Pressure-Temperature Table ITA-10 (Float pipe) 146
3.19.4 Order codes for ITA-10 & ITA-10.0 147
3.20.1 ITA-11 154
3.20.2 ITA-11.0 156
3.20.3 Pressure-Temperature Table ITA-11 (Float pipe) 158
3.20.4 Order codes for ITA-11 & ITA-11.0 159
3.21.1 ITA-12 166
3.21.2 ITA-12.0 168
3.21.3 Pressure-Temperature Table ITA-12 (Float pipe) 170
3.21.4 Order codes for ITA-12 & ITA-12.0 171
3.22.1 ITA-13 178
3.22.2 ITA-13.0 180
3.22.3 Pressure-Temperature Table ITA-13 (Float pipe) 182
3.22.3 Order codes for ITA-13 & ITA-13.0 183

4. Equipment 190
4.1 ITA-3 Cryo, ITA-3 CR64 190
4.2 Armaflex£-insulation 191
4.3 Heat insulation 192
4.4 Technical data switches 193
4.5 Contact NJ-EX 195
4.6 Indication rails 197
4.7 Niveau-source 198
4.8 Reed-contact 199
4.9 Digital Indication with mag. Level Gauges type ITA and Reed Chain 200
4.10 Magnetostrictive level transmitter 203
4.10 Transmitter 205

5. Special constructions 233


5.1 ITA-T1S 233
5.2 ITA-T1R 237

Order codes:
For mag. level gauges
(behind each subchapter of chapter 3)
For add. Equipment 216
For special designs 220
For spare parts 221
For documentation 230
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

1. ISO 9001 Certificate

1
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

2. Functioning and General Information

2.1 Magnetically controlled liquid level gauge type ITA


The product line ITA is used wherever fluid level has to be
monitored, indicated, and controlled in a reliable way, especially
with corrosive, toxic and inflammable fluids with a viscosity up to
max. 5000 mPa s.

The ITA level indicators offer a reliable, accident-free and


maintenance-free usage, through a simple and break-resistant
construction at a maximum process pressure of 320 bar and a
temperature range from –50 through 400 °C. The fluid level is
indicated directly with a separation of the measurement and
indication area. The magnetic transfer of the fluid level from the
tank to the indicator is continuous and vibration-resistant, even
in the case of fast changing levels.

It is possible to mount the indication rail in any position on the


pipe diameter. There is no corrosion of the indication system.
The ITA instruments may be used in open or closed vessels. A
definite level measurement without any power supply is
guaranteed due to a continuous rotation of the wafers, even if a
power loss in the plant occurs.

Functional Principle:

A float chamber (2) is connected (1A and 1B) to the tank (1), and following the law of communicating
tubes, the level in the float chamber is equal to the level of the tank. The float (3) follows the fluid
level and transmits its movements contact-free to the indication rail (4) mounted on the outside. The
float has a special magnet, which rotates the wafers by 180° as it passes them. The result is a clearly
defined level indication, with the level shown in a continuous red stripe strongly contrasted to the
white above. At increasing levels the color of the wafer changes from white to red and vice versa.

The indication rail and the wafers are made of Makrolon so that there will never be a problem of
corrosion in humid and aggressive atmosphere. Each wafer has a permanent magnet, that is why the
indicator is shock proof. Moreover, as there is no turbidness because of product contamination of the
UV-radiation, the readability remains unobjectable even after some years.

All models are available with electronic alarms, which can be mounted at any position during
operation of the system, which renders possible an optimal definition of the min. and max. data
points. The indicator can be equipped with a scale for volume or height (depending on the customer’s
specifications).

2.2 Level Measurement Tasks

1.) Indicating the fluid level


2.) Monitoring the level with alarm contacts
3.) Transferring the level using measurement value sensors (analogue signal 4…20 mA) to
electronic display units
4.) Interface level measurement.

2
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

2.3 Advantages

No risk of glass breakage as a result of the separation of the measurement and indicator areas. The
float principle means that changes of the density in the medium have very little influence on the
indication accuracy.

2.4 Switches / Alarm Contacts

Magnetic level indicators can be equipped with an arbitrary


number of switch contacts. In contrast to electric float switches,
switch contacts may be installed at any position of the stand pipe.
Wherever additional float chambers are needed for float switches,
magnetically controlled level gauges offer a considerable price
benefit.

Electrical level measurement transducers which use the


displacement principle must be recalibrated each time the fluid
density has changed. The price of a magnetically controlled level
indicator with integral electrical measurement transducer is
considerably lower than level measurement transducers. The
reed chain with an R/I measurement transducer can be changed
without interrupting the operation. The measurement chamber is
hermetically sealed – there is no contact between the fluid
chamber and the reed chain.

The switches / alarm contacts are secured with pipe clips, and
can be adjusted to any desired height. The connection is using 3-
core cable or casing terminals. The changeover contact can be
used as opener or closer. The switches are also available as
explosion-proof version.

2.5 Floats

The construction of the float requires a great amount of


technical knowledge. The float with its special magnet can
rotate freely in the float chamber. The Intra construction avoids
a guide wire and other devices. The float materials are stainless
steel, 1.4571(316Ti), 1.4435 (316L) or titanium (PVC, PP,
PVDF in case of the plastics level gauges). Floats without gas-
pre-stressing are used from a minimum density of 0,35 kg/dm³.
The maximum process pressure for sealed floats is 250 bar; at
higher pressures the floats must be relieved from pressure (not
to be used for condensing media). Intra-Automation mag. level
gauges type ITA work
up to a viscosity of 5000 mPa s.

3
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

2.6 Indication rail

The ITA level gauges can be supplied with indication rails made from 2 different materials. Makrolon
indication rails are resistible to breakage. The max. permissible media temperature is 120°C, with
20°C ambient temperature and natural convection as test conditions. The rails are resistible to UV-
radiation and aggressive atmospheres and are sealed against dust by two seal-caps. Aluminum
indication rails can be supplied as one part rail up to a length of 6 m. The sight cover material
depends on the temperature, up to 150°C the material is Makrolon and up to 400°C it is glass. The
surface of the indication rail can b coated with Saekaphen if required, the standard surface is brown-
anodized.

2.7 Materials

The gauge chamber and the floats are made of stainless steel (1.4571), 254SMO (1.4529), titanium,
Hasteloy, PVC, PP, PVDF and PTFE. Other materials on request.

2.8 Special Versions

1. Transmitter, output singal 0…20 or 4…20 mA


2. Steam jacket, e.g. for viscous media
3. Float chamber with Armaflex£-insulation, for temperatures below zero (centigrade)
4. Scale made of Gravoloy (white plastic) or aluminium red anodized
5. Two parts versions without interruption of the indication, for measuring lengths > 5 m
6. Works report DIN 50049
7. Level indicator in Marine design (Germanischer Lloyd, Bureau Veritas, Det Norske Veritas,
Lloyds Register)
8. Usage as an overfilling guard for tanks storing inflammable and non-inflammating water
polluting liquids
9. ITA Cryogenic versions for refrigerants
10. ITA with lining made of PTFE
11. ITA with inside coating made of E-CTFE (Halar)

2.9 Additional Equipment

1. Anti freezing heating belt for use in the open air


2. Vent/drain valves, threaded of flanged connection
3. Measuring scale, divisions to client's specifications
4. Armaflex insulation
5. Protective hose, additional protection of the indicator against dust, dirt and moisture
6. Plastic indicator with armouring

4
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

2.10 Inspection / Certificates

1. Material certificate EN 10204 2.1


2. Material certificate EN 10204 2.2
3. Material certificate EN 10204 3.1/3.2/3.3
4. Test according to NACE
5. Pressure test certificate
6. Pressure test according to "AD-Merkblatt" by the German TÜV
7. Construction and pressure test as per TRD by the TÜV
8. Dye penetration test DIN 54152
9. X-ray-test in accordance with DN 54111 part 1
10. PMI-check
11. ATEX certification
12. General approval of construction inspection in accordance with § 19 water resources law -
WHG - and § 12 law about flammable liquids - VbF
13. Water level controller component check as per VdTÜV/WR91-352
14. Germanischer Lloyd
15. Certificate of Passivation
16. Weight certificate
17. PED 97/23/EG

5
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3. Level Gauges in Details

3.1.1 ITA-3

Characteristics: PN16 / Float pipe and flange material: 1.4404

Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug

6
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-3

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 2 mm welded,
60,3 x 2 mm seamless
2" Sch10
necking connection or buttweld with T-pieces
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 150#),
Welding or threaded stud
Drain/Vent connections: Plug R1/2" (for more please see order codes)
Pipe material: 1.4404; 1.4435; 1.4539; Hastelloy C4 (2.4610);
Inconel 625 (2.4856); Inconel 825 (2.4858);
Titan (3.7035) (other materials on request)
Flange material: same as pipe material
Float material: 1.4404
Titan, Titan/E-CTFE-coated
Operation temperature: -50..+400 °C
Operation pressure: max. 16 bar
Operation density: min. 0,3761 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket PTFE up to 100 °C
Klingersil C4400 up to 175 °C
Graphit spiral wound up to 400 °C**
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type
Length:
-270 mm
-130 mm
-150 mm
-210 mm
-330 mm
-430 mm
-530 mm
-630 mm
Standard dimensions: -A = 240 mm*
-B = 130 mm
- C = 40 mm
Base equipment printed in bold letters!
*for densities < 0,7374 kg/dm³ enlarge the scale A
**only with vent- and/or drain flanges DN50 resp. 2"

7
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.1.2 ITA-3.0

Characteristics: PN16 / Float pipe: 1.4404 and flanges : CS

Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug

8
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-3.0

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 2 mm welded,
60,3 x 2 mm seamless
2" Sch10
necking connection or buttweld with T-pieces
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 150#),
Welding or threaded stud
Drain/Vent connections: Plug R1/2" (for more please see order codes)
Pipe material: 1.4404
Flange material: CS
Float material: 1.4404
Titan, Titan/E-CTFE-coated
Operation temperature: -50..+400 °C
Operation pressure: max. 16 bar
Operation density: min. 0,3761 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket PTFE up to 100 °C
Klingersil C4400 up to 175 °C
Graphit spiral wound up to 400 °C**
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type
Length:
-270 mm
-130 mm
-150 mm
-210 mm
-330 mm
-430 mm
-530 mm
-630 mm
Standard dimensions: -A = 240 mm*
-B = 130 mm
- C = 40 mm
Base equipment printed in bold letters!
*for densities < 0,7374 kg/dm³ enlarge the scale A
**only with vent- and/or drain flanges DN50 resp. 2"

9
3.1.3 Pressure-Temperature Table ITA-3 (Float pipe)

10
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.1.4 Order codes ITA-3 & ITA-3.0

Mag. Level Gauge


ITA-3 & ITA-3.0 PN16/150 lbs

Order codes mag. level gauge type ITA- 3 & ITA-3.0 PN16/150 lbs

Code Description

1. Float pipe welded


ITA-3
Dimensions 60,3 x 2 mm
2. c to c distance
L c to c distance in mm
3. Design
0 without indication rail each 100 mm
1 Indication rail material: Makrolon max. 120 °C; each 100 mm
2 Indication rail material: Aluminium max. 400 °C, pro 100 mm
3 Indication rail material: 1.4401 max. 400 °C, pro 100 mm
4. c to c distance < 5000 mm
0 < 5000 mm - one part design
1 > 5000 mm - with flange connection; DN 32 PN 16, two or more parts design
2 > 5000 mm - with flange connection; DN 50 PN 16, two or more parts design
A > 5000 mm - with flange connection; 2" ANSI 150 lbs, two or more parts design
5. Process connection side/side
0 without
Y Welding connection (please specify)
Z Threaded connection (please specify)
1 Flanges DN 15 PN 16
2 Flanges DN 20 PN 16
3 Flanges DN 25 PN 16
4 Flanges DN 32 PN 16
5 Flanges DN 40 PN 16
6 Flanges DN 50 PN 16
A Flanges 1/2" ANSI 150 lbs
B Flanges 3/4" ANSI 150 lbs
C Flanges 1" ANSI 150 lbs
D Flanges 1 1/4" ANSI 150 lbs
E Flanges 1 1/2" ANSI 150 lbs
F Flanges 2" ANSI 150 lbs
Flanges 300 lbs
0 without
H additional price for flanges 300 lbs

11
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3 & ITA-3.0 PN16/150 lbs

Order codes mag. level gauge type ITA- 3 & ITA-3.0 PN16/150 lbs

Code Description

5.1 Surface side flanges


0 without
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface Nut (DIN2512)
G Surface groove large
H Surface Feder (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
6. Side studs welded with T-pieces for 100 % X-ray testing
0 without
T T-pieces
7. Float removal flange (bottom side)
0 without
1 End cap (only if float removal flange (top side))
2 Flange DN 32 PN 16 incl. blind flange
3 Flange DN 50 PN 16 incl. blind flange
A Flange 2" ANSI 150 lbs incl. blind flange
4 Flange DN 50 PN 16 reinforced for shut off valve on side
C Flange 2" ANSI 150 lbs reinforced for shut off valve on side
7.1 Surface float removal flange (bottom side) (only DN50 or 2")
0 without (Float removal flange (bottom side) = end cap or < DN50 or 2")
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"

12
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3 & ITA-3.0 PN16/150 lbs

Order codes mag. level gauge type ITA- 3 & ITA-3.0 PN16/150 lbs

Code Description

7.2 Bolts & nuts float removal flange (bottom side)


0 without (Float removal flange (bottom side) = end cap)
31 M16 x 65 mm; mat. zinced steel; flange DN 32 PN 16; DN 931
42 M16 x 65 mm; mat. A2-70; flange DN 32 PN 16; DIN 931
63 M16 x 65 mm; mat. zinced steel; flange DN 50 PN 16; DIN 931
64 M16 x 65 mm; mat. A2-70; flange DN 50 PN 16;K DIN 931
3X M16 x 65 mm, PTFE-coated, flanges DN 50 PN 16
3A 5/8" x 83 mm;RF, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3B 5/8" x 83 mm;RF, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3C 5/8" x 95 mm;RTJ, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3D 5/8" x 95 mm;RTJ, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3T 5/8" x 83 mm;RF, mat.: PTFE coated, flange 2" 150 lbs
3V 5/8" x 95 mm;RTJ, mat.: PTFE coated, flange 2" 150 lbs
8. Drain plug
0 without
1 Drain plug G 1/2" with soft iron gasket
4 Drain plug 1/2" NPT
5 Drain plug 3/4" NPT
6 Drain plug 1" NPT
9. Additional drain flange, open
0 without
1 Drain stud with flange DN 15 PN 16
2 Drain stud with flange DN 20 PN 16
3 Drain stud with flange DN 25 PN 16
4 Drain stud with flange DN 32 PN 16
5 Drain stud with flange DN 40 PN 16
A Drain stud with flange 1/2" ANSI 150 lbs
B Drain stud with flange 3/4" ANSI 150 lbs
C Drain stud with flange 1" ANSI 150 lbs
D Drain stud with flange 1 1/4" ANSI 150 lbs
E Drain stud with flange 1 1/2" ANSI 150 lbs
9.1 Drain flange with concentric reducer (X-ray testing)
0 without
1 DN 15 PN 16
2 DN 20 PN 16
3 DN 25 PN 16
4 DN 32 PN 16
5 DN 40 PN 16
A 1/2" ANSI 150 lbs
B 3/4" ANSI 150 lbs
C 1" ANSI 150 lbs
D 1 1/4" ANSI 150 lbs
E 1 1/2" ANSI 150 lbs

13
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3 & ITA-3.0 PN16/150 lbs

Order codes mag. level gauge type ITA- 3 & ITA-3.0 PN16/150 lbs

Code Bezeichnung

9.2 Surface open drain flange


0 without (additional drain flange = without)
A Suface Form C
B Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large (ANSI B16.5)
H Surface tongue (DIN2512)
K Surface tongue-large (ANSI B16.5)
L Surface RTJ (ANSI B16.5) 1/2" to 2"
10. Float pipe top end finish
0 without
1 End cap
2 Flange with blind flange DN 32 PN 16
3 Flange with blind flange DN 50 PN 16
5 Flange with blind flange DN 50 PN 16, reinforced for shut off valve on side
4 Flange with blind flange 2" ANSI 150 lbs
4 Flange with blind flange 2" ANSI 150 lbs reinforced for shut off valve on side
10.1 Surface float pipe top end finish flange (only DN50 or 2")
0 without (Float pipe top end finish = End cap or < DN50 or 2")
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
10.2 Bolts & nuts float pipe top end finish flange (only DN50 or 2")
0 without (Float removal flange (bottom side) = end cap)
31 M16 x 65 mm; mat. zinced steel; flange DN 32 PN 16; DN 931
42 M16 x 65 mm; mat. A2-70; flange DN 32 PN 16; DIN 931
63 M16 x 65 mm; mat. zinced steel; flange DN 50 PN 16; DIN 931
64 M16 x 65 mm; mat. A2-70; flange DN 50 PN 16;K DIN 931
3X M16 x 65 mm, PTFE-coated, flanges DN 50 PN 16
3A 5/8" x 83 mm;RF, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3B 5/8" x 83 mm;RF, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3C 5/8" x 95 mm;RTJ, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3D 5/8" x 95 mm;RTJ, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3T 5/8" x 83 mm;RF, mat.: PTFE coated, flange 2" 150 lbs
3V 5/8" x 95 mm;RTJ, mat.: PTFE coated, flange 2" 150 lbs

14
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3 & ITA-3.0 PN16/150 lbs

Order codes mag. level gauge type ITA- 3 & ITA-3.0 PN16/150 lbs

Code Description

11. Vent plug at top end


0 without
1 Vent plug G 1/2" with soft iron gasket
4 Vent plug 1/2" NPT
5 Vent plug 3/4" NPT
6 Vent plug 1" NPT
11.1 Vent flange welded to end cap instead of vent plug
0 without
1 Flanged DN 15 PN 16 (socket weld construction to endcap)
2 Flanged DN 20 PN 16 (socket weld construction to endcap)
3 Flanged DN 25 PN 16 (socket weld construction to endcap)
4 Flanged DN 32 PN 16 (socket weld construction to endcap)
5 Flanged DN 40 PN 16 (socket weld construction to endcap)
6 Flanged DN 50 PN 16 (socket weld construction to endcap)
A Flanged 1/2" ANSI 150 lbs (socket weld construction to endcap)
B Flanged 3/4" ANSI 150 lbs (socket weld construction to endcap)
C Flanged 1" ANSI 150 lbs (socket weld construction to endcap)
D Flanged 1 1/4" ANSI 150 lbs (socket weld construction to endcap)
E Flanged 1 1/2" ANSI 150 lbs (socket weld construction to endcap)
11.2 Vent flange with concentric reducer (X-ray testing)
0 without
1 DN 15 PN 16
2 DN 20 PN 16
3 DN 25 PN 16
4 DN 32 PN 16
5 DN 40 PN 16
A 1/2" ANSI 150 lbs
B 3/4" ANSI 150 lbs
C 1" ANSI 150 lbs
D 1 1/4" ANSI 150 lbs
E 1 1/2" ANSI 150 lbs
11.3 Surface vent flange welded to end cap (only DN50 or 2")
0 without (Vent flange welded to end cap = without)
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"

15
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3 & ITA-3.0 PN16/150 lbs

Order codes mag. level gauge type ITA- 3 & ITA-3.0 PN16/150 lbs

Code Description

12. Counter flanges


0 without
1 DN 15 PN 16
2 DN 20 PN 16
3 DN 25 PN 16
4 DN 32 PN 16
5 DN 40 PN 16
6 DN 50 PN 16
A 1/2" 150 lbs
B 3/4" 150 lbs
C 1" 150 lbs
D 1 1/4" 150 lbs
E 1 1/2" 150 lbs
F 2" 150 lbs
12.1 Surface counter flanges
0 without (Counter flanges = without)
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
12.2 Bolts & Nuts counter flanges
0 without
31 M16 x 65 mm; mat. zinced steel; flange DN 32 PN 16; DN 931
42 M16 x 65 mm; mat. A2-70; flange DN 32 PN 16; DIN 931
63 M16 x 65 mm; mat. zinced steel; flange DN 50 PN 16; DIN 931
64 M16 x 65 mm; mat. A2-70; flange DN 50 PN 16;K DIN 931
3X M16 x 65 mm, PTFE-coated, flanges DN 50 PN 16
3A 5/8" x 83 mm;RF, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3B 5/8" x 83 mm;RF, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3C 5/8" x 95 mm;RTJ, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3D 5/8" x 95 mm;RTJ, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3T 5/8" x 83 mm;RF, mat.: PTFE coated, flange 2" 150 lbs
3V 5/8" x 95 mm;RTJ, mat.: PTFE coated, flange 2" 150 lbs
13. Additional bracket welded to the float pipe
0 without
H Bracket
14. Float pipe seamless
0 without
S 60,3 x 2 mm seamless; each 100 mm

16
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3 & ITA-3.0 PN16/150 lbs

Prices for mag. Level Gauges type: ITA-3 & ITA-3.0 PN16/150 lbs

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
3V0100K1 16 316SS 52 125 1,4907 N
3V0100K3 16 316SS 52 125 1,0524 N only with 316SS or Aluminium indication rail
3V0120K1 16 316SS 52 145 1,2346 N
3V0120K3 16 316SS 52 145 0,9034 N only with 316SS or Aluminium indication rail
3V0150K1 16 316SS 52 175 0,9905 N
3V0150K3 16 316SS 52 175 0,8606 N only with 316SS or Aluminium indication rail
3V0180K1 16 316SS 52 205 0,8781 N
3V0180K3 16 316SS 52 205 0,7022 N only with 316SS or Aluminium indication rail
3V0240K1 16 316SS 52 265 0,7374 N
3V0240K3 16 316SS 52 265 0,6209 N only with 316SS or Aluminium indication rail
3V1240K1 40 316SS 52 265 1,000 N
3T0100K1 16 Titanium 50,8 125 1,1788 N do not use with hydrogen or alcohol compounds
3T0100K3 16 Titanium 50,8 125 0,7821 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0120K1 16 Titanium 50,8 145 0,9646 N do not use with hydrogen or alcohol compounds
3T0120K3 16 Titanium 50,8 145 0,6514 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0150K1 16 Titanium 50,8 175 0,7763 N do not use with hydrogen or alcohol compounds
3T0150K3 16 Titanium 50,8 175 0,5675 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0180K1 16 Titanium 50,8 205 0,6716 N do not use with hydrogen or alcohol compounds
3T0180K3 16 Titanium 50,8 205 0,5094 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0240K1 16 Titanium 50,8 265 0,5723 N do not use with hydrogen or alcohol compounds
3T0240K3 16 Titanium 50,8 265 0,4550 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0300K1 16 Titanium 50,8 325 0,4955 N do not use with hydrogen or alcohol compounds
3T0300K3 16 Titanium 50,8 325 0,4063 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0400K1 16 Titanium 50,8 425 0,4358 N do not use with hydrogen or alcohol compounds
3T0400K3 16 Titanium 50,8 425 0,3719 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0500K1 16 Titanium 50,8 525 0,4017 N do not use with hydrogen or alcohol compounds
3T0500K3 16 Titanium 50,8 525 0,3539 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0600K1 16 Titanium 50,8 625 0,3761 N do not use with hydrogen or alcohol compounds
3T0600K3 16 Titanium 50,8 625 0,3371 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3H0150K1 16 Titanium, 52 175 0,902 N
Halar-coated
3HC012K1 16 Hastelloy C4 52 175 1,2455 N
3HC024K1 16 Hastelloy C4 52 265 0,7510 N
3HC024K3 16 Hastelloy C4 52 265 0,6296 N only with 316SS or Aluminium indication rail

For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

17
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.1.4 Order code scheme for ITA-3 & ITA-3.0

1. Type of level gauge ITA-3 or ITA-3.0


2. C to C distance in mm [or inches]
3. Design
4. C to C distance > 5000 mm
5. Process connection [side/side]
5.1 Surface side flanges
6. Side studs welded with T-pieces for 100 % X-ray-testing
7. Float removal flange
7.1 Surface float removal flange
7.2 Bolts & nuts float removal flange
8. Drain plug
9. Additional drain flange, open

ITA-3

ITA-3.0

9.1 Drain flange with concentric reducer (X-ray testing)


9.2 Surface open drain flange
10. Float pipe top end finish
10.1 Surface top end finish flange
10.2 Bolts and nuts rop end finish flange
11. Vent plug at top end
11.1 Vent flange welded to end cap instead of vent plug
11.2 Vent flange with concentric reducer (X-ray testing)
11.3 Surface vent flange welded to end cap
12. Counter flanges
12.1 Surface counter flanges
12.2 Bolts & nuts counter flanges
13. Additional bracket welded to the float pipe
14. Float pipe seamless
15. Float

18
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.2.1 ITA-3 Cryo for cryogenic applications, non-vaporizing fluid

Characteristics: PN16 / Float pipe and flange material: 1.4404

Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Drain plug
2 c to c distance 10 Additional drain flange, open
3 Design (indication rail) 11 Float pipe top end finish
4 Armaflex£ insulation 12 Vent plug
6 Process connection side/side 13 Counter flanges
7 Side studs welded with T pieces 14 Additional bracket
for 100 % X-ray testing 15 Float pipe seamless
8 Float removal flange 16 Float

19
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-3 Cryo

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 2 mm welded,
necking connection or buttweld with T-pieces
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 150#),
Welding or threaded stud
Drain/Vent connections: Plug R1/2" (for more please see order codes)
Pipe material: 1.4404; 1.4435; 1.4539; Hastelloy C4 (2.4610);
Inconel 625 (2.4856); Inconel 825 (2.4858);
Titan (3.7035) (other materials on request)
Flange material: same as pipe material
Float material: 1.4404
Titan, Titan/E-CTFE-coated
Operation temperature: -200..+100 °C
Operation pressure: max. 16 bar
Operation density: min. 0,4017 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS (min. -10°C)
SS or material in acc. with DIN 17280
Gasket PTFE min -150 °C
Klingersil TOP Chem 2000
Indication rail: Aluminium
1.4301
Float types: Cylindical, sealed type
Length:
-270 mm*
Base equipment printed in bold letters!
*not for vaporizing media (e.g. ammonia)

20
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.2.2 Order codes ITA-3 Cryo

Mag. Level Gauge


ITA-3-Cryo for cryogenic applications
non-vaporizing fluid
Order codes for mag. level gauge type: ITA-3 Cryo

Code Description

1. Float pipe welded


ITA-3-Cryo
Dimensions 60,3 x 2 mm
2. C to C distance
L C to C distance in mm
3. Design
0 without indication rail each 100 mm
1 Indication rail material: Aluminium max. 400 °C, each 100 mm
2 Indication rail material: 1.4401 max. 400 °C, each 100 mm
4. Armaflex-Insulation
0 without insulation
F Thickness: 12 mm, up to -15 °C
R Thickness: 30 mm, up to -50 °C
T Thickness: 70 mm, up to -200 °C, incl. Makrolon window
5. C to C distance < 5000 mm
0 < 5000 mm - one part design
1 > 5000 mm - with flange connection; DN 32 PN 16, two or more parts design
2 > 5000 mm - with flange connection; DN 50 PN 16, two or more parts design
A > 5000 mm - with flange connection; 2" ANSI 150 lbs, two or more parts design
6. Process connection side/side
Y Welding connection (please specify)
Z Threaded connection (please specify)
1 Flanges DN 15 PN 16
2 Flanges DN 20 PN 16
3 Flanges DN 25 PN 16
4 Flanges DN 32 PN 16
5 Flanges DN 40 PN 16
6 Flanges DN 50 PN 16
A Flanges 1/2" ANSI 150 lbs
B Flanges 3/4" ANSI 150 lbs
C Flanges 1" ANSI 150 lbs
D Flanges 1 1/4" ANSI 150 lbs
E Flanges 1 1/2" ANSI 150 lbs
F Flanges 2" ANSI 150 lbs
6.1 Surface side flanges
0 without
F Surface groove (DIN2512)
H Surface tongue (DIN2512)
G groove large, ANSI B16.5
K tongue large, ANSI B16.5
21
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3-Cryo for cryogenic applications
non-vaporizing fluid
Order codes for mag. level gauge type: ITA-3 Cryo

Code Description

7. Side studs welded with T-pieces for 100 % X-ray testing


0 without
T T-pieces
8. Float removal flange (bottom side)
1 End cap (only if float removal flange (top side))
2 Flange DN 32 PN 16 incl. blind flange
3 Flange DN 50 PN 16 incl. blind flange
A Flange 2" ANSI 150 lbs incl. blind flange
4 Flange DN 50 PN 16 reinforced for shut off valve on side
B Flange 2" ANSI 150 lbs reinforced for shut off valve on side
8.1 Surface float removal flange (bottom side) (only DN50 or 2")
0 without (Float removal flange (bottom side) = end cap or < DN50 or 2")
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
8.2 Bolts & nuts float removal flange (bottom side)
0 without (Float removal flange (bottom side) = end cap)
63 M16 x 65 mm; mat. zinced steel; flange DN 50 PN 16; DIN 931
64 M16 x 65 mm; mat. A2-70; flange DN 50 PN 16;K DIN 931
3X M16 x 65 mm, PTFE-coated, flanges DN 50 PN 16
3A 5/8" x 83 mm;RF, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3B 5/8" x 83 mm;RF, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3C 5/8" x 95 mm;RTJ, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3D 5/8" x 95 mm;RTJ, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3T 5/8" x 83 mm;RF, mat.: PTFE coated, flange 2" 150 lbs
3V 5/8" x 95 mm;RTJ, mat.: PTFE coated, flange 2" 150 lbs
9. Drain plug
0 without
1 Drain plug G 1/2" with soft iron gasket
4 Drain plug 1/2" NPT
5 Drain plug 3/4" NPT
6 Drain plug 1" NPT

22
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3-Cryo for cryogenic applications
non-vaporizing fluid
Order codes for mag. level gauge type: ITA-3 Cryo

Code Description

10. Additional drain flange, open


0 without
1 Drain stud with flange DN 15 PN 16
2 Drain stud with flange DN 20 PN 16
3 Drain stud with flange DN 25 PN 16
4 Drain stud with flange DN 32 PN 16
5 Drain stud with flange DN 40 PN 16
A Drain stud with flange 1/2" ANSI 150 lbs
B Drain stud with flange 3/4" ANSI 150 lbs
C Drain stud with flange 1" ANSI 150 lbs
D Drain stud with flange 1 1/4" ANSI 150 lbs
E Drain stud with flange 1 1/2" ANSI 150 lbs
10.1 Surface open drain flange
0 without (Float removal flange (bottom side) = end cap or < DN50 or 2")
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
11. Float pipe top end finish
1 End cap
2 Flange with blind flange DN 32 PN 16
3 Flange with blind flange DN 50 PN 16
A Flange with blind flange 2" ANSI 150 lbs
11.1 Surface float pipe top end finish flange (only DN50 or 2")
0 without (Float removal flange (bottom side) = end cap or < DN50 or 2")
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"

23
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3-Cryo for cryogenic applications
non-vaporizing fluid
Order codes for mag. level gauge type: ITA-3 Cryo

Code Description

11.2 Bolts & nuts float pipe top end finish flange (only DN50 or 2")
0 without (Float removal flange (bottom side) = end cap)
63 M16 x 65 mm; mat. zinced steel; flange DN 50 PN 16; DIN 931
64 M16 x 65 mm; mat. A2-70; flange DN 50 PN 16;K DIN 931
3X M16 x 65 mm, PTFE-coated, flanges DN 50 PN 16
3A 5/8" x 83 mm;RF, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3B 5/8" x 83 mm;RF, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3C 5/8" x 95 mm;RTJ, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3D 5/8" x 95 mm;RTJ, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3T 5/8" x 83 mm;RF, mat.: PTFE coated, flange 2" 150 lbs
3V 5/8" x 95 mm;RTJ, mat.: PTFE coated, flange 2" 150 lbs
12. Vent plug at top end
0 without
1 Vent plug G 1/2" with soft iron gasket
2 Vent plug 1/2" NPT
3 Vent plug 3/4" NPT
4 Vent plug 1" NPT
12.1 Vent flange welded to end cap instead of vent plug
0 without
1 Flanged DN 15 PN 16 (socket weld construction to endcap)
2 Flanged DN 20 PN 16 (socket weld construction to endcap)
3 Flanged DN 25 PN 16 (socket weld construction to endcap)
4 Flanged DN 32 PN 16 (socket weld construction to endcap)
5 Flanged DN 40 PN 16 (socket weld construction to endcap)
6 Flanged DN 50 PN 16 (socket weld construction to endcap)
A Flanged 1/2" ANSI 150 lbs (socket weld construction to endcap)
B Flanged 3/4" ANSI 150 lbs (socket weld construction to endcap)
C Flanged 1" ANSI 150 lbs (socket weld construction to endcap)
D Flanged 1 1/4" ANSI 150 lbs (socket weld construction to endcap)
E Flanged 1 1/2" ANSI 150 lbs (socket weld construction to endcap)
12.2 Surface vent flange welded to end cap (only DN50 or 2")
0 without (Vent flange welded to end cap = without)
B Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (ANSI)
F Surface groove (DIN2512)
G Surface groove large ANSI
H Surface tongue (DIN2512)
K Surface tongue-large ANSI
L Surface RTJ (ANSI) 1/2" bis 2"

24
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3-Cryo for cryogenic applications
non-vaporizing fluid
Order codes for mag. level gauge type: ITA-3 Cryo

Code Description

13. Counter flanges


0 without
1 DN 15 PN 16
2 DN 20 PN 16
3 DN 25 PN 16
4 DN 32 PN 16
5 DN 40 PN 16
6 DN 50 PN 16
A 1/2" 150 lbs
B 3/4" 150 lbs
C 1" 150 lbs
D 1 1/4" 150 lbs
E 1 1/2" 150 lbs
F 2" 150 lbs
13.1 Surface counter flanges
0 without (Counter flanges = without)
F Surface groove (DIN2512)
H Surface tongue (DIN2512)
13.2 Bolts & Nuts counter flanges
0 without (Float removal flange (bottom side) = end cap)
63 M16 x 65 mm; mat. zinced steel; flange DN 50 PN 16; DIN 931
64 M16 x 65 mm; mat. A2-70; flange DN 50 PN 16;K DIN 931
3X M16 x 65 mm, PTFE-coated, flanges DN 50 PN 16
3A 5/8" x 83 mm;RF, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3B 5/8" x 83 mm;RF, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3C 5/8" x 95 mm;RTJ, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3D 5/8" x 95 mm;RTJ, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3T 5/8" x 83 mm;RF, mat.: PTFE coated, flange 2" 150 lbs
3V 5/8" x 95 mm;RTJ, mat.: PTFE coated, flange 2" 150 lbs
14. Additional bracket welded to the float pipe
0 without
H Bracket
15. Float pipe seamless
0 without
S 60,3 x 2 mm seamless; each 100 mm

25
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3-Cryo for cryogenic applications
non-vaporizing fluid
Order codes for mag. level gauge type: ITA-3 Cryo

Code Description

Floats

Pressure Diameter min. Density vented


Material notes
[bar] [mm] [kg/dm³] [Y/N]
3C0240K1 16 Titanium 50,8 0,5723 N do not use for hydrogene or alcohol
compounds
3C0500K1 do not use for hydrogene or alcohol
16 Titanium 45 0,5509 N compounds
3C0500K3 16 Titanium 45 0,5038 N only with 316SS or Aluminium
inication rail, do not use for
hydrogene or alcohol compounds

26
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.2.2 Order code scheme for ITA-3 Cryo

1. Type of level gauge ITA-3 Cryo


2. C to C distance in mm [or inches]
3. Design
4. Armaflex insulation
5. C to C distance > 5000 mm
6. Process connection [side/side]
6.1 Surface side flanges
7. Side studs welded with T-pieces for 100 % X-ray-testing
8. Float removal flangeSurface float removal flange
8.1 Surface float removal flange
8.2 Bolts & nuts float removal flange
9. Drain plug

ITA-3-Cryo

10. Additional drain flange, open


10.1 Surface open drain flange
11. Float pipe top end finish
11.1 Surface top end finish flange
11.2 Bolts and nuts rop end finish flange
12. Vent plug at top end
12.1 Vent flange welded to end cap instead of vent plug
12.2 Surface vent flange
13. Counter flanges
13.1 Surface counter flanges
13.2 Bolts & nuts counter flanges
14. Additional bracket welded to the float pipe
15. Float pipe seamless
16. Float

27
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.3.1 ITA-3 CR64 for cryogenic applications, vaporizing fluids

Characteristics: PN16 / Float pipe and flange material: 1.4571

Key:
1 Float pipe welded, dimensions 64 x 2 mm 9 Drain plug
2 c to c distance 10 Additional drain flange, open
3 Design (indication rail) 11 Float pipe top end finish
4 Armaflex insulation 12 Vent plug
6 Process connection side/side 13 Counter flanges
7 Side studs welded with T pieces 14 Additional bracket
for 100 % X-ray testing 15 Float pipe seamless
8 Float removal flange 16 Float

28
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-3 CR64

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 64 x 2 mm welded,
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 150#),
Welding or threaded stud
Drain/Vent connections: Plug G1/2" (for more please see order codes)
Pipe material: 1.4571; 1.4435; 1.4539; Hastelloy C4 (2.4610);
Inconel 625 (2.4856); Inconel 825 (2.4858);
Titan (3.7035) (other materials on request)
Flange material: same as pipe material
Float material: Titan, Titan/E-CTFE-coated
Operation temperature: -200..+100 °C
Operation pressure: max. 16 bar
Operation density: min. 0,4017 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS (min. -10°C)
SS or material in acc. with DIN 17280
Gasket PTFE min -150 °C
Klingersil TOP Chem 2000
Indication rail: Aluminium
1.4301
Float types: Cylindical, sealed type
Length:
-∅50,8 x 270 mm*
-∅50,8 x 530 mm
Base equipment printed in bold letters!
*For use with vaporizing media (e.g. ammonia)

29
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.3.2 Order codes ITA-3 CR64

Mag. Level Gauge


ITA-3 CR64 for cryogenic applications, vaporizing fluids
Float pipe and flange material 1.4571

Order codes for mag. level gauge type ITA-3-CR64 for cryogenic applications

Code Description

1. Float pipe welded


ITA-3 CR64
Dimensions 64 x 2 mm
2. C to C distance
L C to C distance in mm
3. Design
0 without indication rail each 100 mm
1 Indication rail material: Aluminium max. 400 °C, each 100 mm
2 Indication rail material: 1.4401 max. 400 °C, each 100 mm
4. Armaflex-Insulation
0 without insulation
F Thickness: 12 mm, up to -15 °C
R Thickness: 30 mm, up to -50 °C
T Thickness: 70 mm, up to -200 °C, incl. Makrolon window
5. C to C distance < 5000 mm
A < 5000 mm - without flange connection; DN 32 PN 16
B > 5000 mm - with flange connection; DN 32 PN 16
6. Process connection side/side
Y Welding connection (please specify)
Z Threaded connection (please specify)
1 Flanges DN 15 PN 16
2 Flanges DN 20 PN 16
3 Flanges DN 25 PN 16
4 Flanges DN 32 PN 16
5 Flanges DN 40 PN 16
6 Flanges DN 50 PN 16
A Flanges 1/2" ANSI 150 lbs
B Flanges 3/4" ANSI 150 lbs
C Flanges 1" ANSI 150 lbs
D Flanges 1 1/4" ANSI 150 lbs
E Flanges 1 1/2" ANSI 150 lbs
F Flanges 2" ANSI 150 lbs
6.1 Surface side flanges
0 without
F Surface groove (DIN2512)
H Surface tongue (DIN2512)
7. Side studs welded with T-pieces for 100 % X-ray testing
0 without
T T-pieces
8. Float removal flange (bottom side)
1 End cap (only if float removal flange (top side))
2 Flange DN 32 PN 16 incl. blind flange
3 Flange DN 50 PN 16 incl. blind flange
A Flange 2" ANSI 150 lbs incl. blind flange
4 Flange DN 50 PN 16 reinforced for shut off valve on side
B Flange 2" ANSI 150 lbs reinforced for shut off valve on side

30
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3 CR64 for cryogenic applications, vaporizing fluids
Float pipe and flange material 1.4571

Order codes for mag. level gauge type ITA-3-CR64 for cryogenic applications

Code Description

8.1 Surface float removal flange (bottom side) (only DN50 or 2")
0 without (Float removal flange (bottom side) = end cap or < DN50 or 2")
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
8.2 Bolts & nuts float removal flange (bottom side)
0 without (Float removal flange (bottom side) = end cap)
63 M16 x 65 mm; mat. zinced steel; flange DN 50 PN 16; DIN 931
64 M16 x 65 mm; mat. A2-70; flange DN 50 PN 16;K DIN 931
3X M16 x 65 mm, PTFE-coated, flanges DN 50 PN 16
3A 5/8" x 83 mm;RF, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3B 5/8" x 83 mm;RF, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3C 5/8" x 95 mm;RTJ, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3D 5/8" x 95 mm;RTJ, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3T 5/8" x 83 mm;RF, mat.: PTFE coated, flange 2" 150 lbs
3V 5/8" x 95 mm;RTJ, mat.: PTFE coated, flange 2" 150 lbs
9. Drain plug
0 without
1 Drain plug G 1/2" with soft iron gasket
2 Drain plug 1/2" NPT
3 Drain plug 3/4" NPT
4 Drain plug 1" NPT
10. Additional drain flange, open
0 without
1 Drain stud with flange DN 15 PN 16
2 Drain stud with flange DN 20 PN 16
3 Drain stud with flange DN 25 PN 16
4 Drain stud with flange DN 32 PN 16
5 Drain stud with flange DN 40 PN 16
6 Drain stud with flange DN 50 PN 16
A Drain stud with flange 1/2" ANSI 150 lbs
B Drain stud with flange 3/4" ANSI 150 lbs
C Drain stud with flange 1" ANSI 150 lbs
D Drain stud with flange 1 1/4" ANSI 150 lbs
E Drain stud with flange 1 1/2" ANSI 150 lbs
F Drain stud with flange 2" ANSI 150 lbs

31
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3 CR64 for cryogenic applications, vaporizing fluids
Float pipe and flange material 1.4571

Order codes for mag. level gauge type ITA-3-CR64 for cryogenic applications

Code Description

10.1 Surface open drain flange


0 without (Float removal flange (bottom side) = end cap or < DN50 or 2")
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
11. Float pipe top end finish
1 End cap
2 Flange with blind flange DN 32 PN 16
3 Flange with blind flange DN 50 PN 16
A Flange with blind flange 2" ANSI 150 lbs
11.1 Surface float pipe top end finish flange (only DN50 or 2")
0 without (Float removal flange (bottom side) = end cap or < DN50 or 2")
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
11.2 Bolts & nuts float pipe top end finish flange (only DN50 or 2")
0 without (Float removal flange (bottom side) = end cap)
63 M16 x 65 mm; mat. zinced steel; flange DN 50 PN 16; DIN 931
64 M16 x 65 mm; mat. A2-70; flange DN 50 PN 16;K DIN 931
3X M16 x 65 mm, PTFE-coated, flanges DN 50 PN 16
3A 5/8" x 83 mm;RF, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3B 5/8" x 83 mm;RF, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3C 5/8" x 95 mm;RTJ, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3D 5/8" x 95 mm;RTJ, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3T 5/8" x 83 mm;RF, mat.: PTFE coated, flange 2" 150 lbs
3V 5/8" x 95 mm;RTJ, mat.: PTFE coated, flange 2" 150 lbs
12. Vent plug at top end
0 without
1 Vent plug G 1/2" with soft iron gasket
2 Vent plug 1/2" NPT
3 Vent plug 3/4" NPT
4 Vent plug 1" NPT

32
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3 CR64 for cryogenic applications, vaporizing fluids
Float pipe and flange material 1.4571

Order codes for mag. level gauge type ITA-3-CR64 for cryogenic applications

Code Description

12.1 Vent flange welded to end cap instead of vent plug


0 without
1 Flanged DN 15 PN 16 (socket weld construction to endcap)
2 Flanged DN 20 PN 16 (socket weld construction to endcap)
3 Flanged DN 25 PN 16 (socket weld construction to endcap)
4 Flanged DN 32 PN 16 (socket weld construction to endcap)
5 Flanged DN 40 PN 16 (socket weld construction to endcap)
6 Flanged DN 50 PN 16 (socket weld construction to endcap)
A Flanged 1/2" ANSI 150 lbs (socket weld construction to endcap)
B Flanged 3/4" ANSI 150 lbs (socket weld construction to endcap)
C Flanged 1" ANSI 150 lbs (socket weld construction to endcap)
D Flanged 1 1/4" ANSI 150 lbs (socket weld construction to endcap)
E Flanged 1 1/2" ANSI 150 lbs (socket weld construction to endcap)
12.2 Surface vent flange welded to end cap (only DN50 or 2")
0 without (Vent flange welded to end cap = without)
A Surface RF
B Surface Form D Rz=40
C Surface Form E Rz=16
D Surface RFSF (ANSI)
E Surface groove (DIN2512)
F Surface groove large ANSI
G Surface tongue (DIN2512)
H Surface tongue-large ANSI
K Surface RTJ (ANSI) 1/2" bis 2"
L Dichtfläche RTJ (ANSI)
13. Counter flanges
0 without
1 DN 15 PN 16
2 DN 20 PN 16
3 DN 25 PN 16
4 DN 32 PN 16
5 DN 40 PN 16
6 DN 50 PN 16
A 1/2" 150 lbs
B 3/4" 150 lbs
C 1" 150 lbs
D 1 1/4" 150 lbs
E 1 1/2" 150 lbs
F 2" 150 lbs
13.1 Surface counter flanges
0 without (Counter flanges = without)
F Surface groove (DIN2512)
H Surface tongue (DIN2512)

33
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3 CR64 for cryogenic applications, vaporizing fluids
Float pipe and flange material 1.4571

Order codes for mag. level gauge type ITA-3-CR64 for cryogenic applications

Code Description

13.2 Bolts & Nuts counter flanges


0 without (Float removal flange (bottom side) = end cap)
63 M16 x 65 mm; mat. zinced steel; flange DN 50 PN 16; DIN 931
64 M16 x 65 mm; mat. A2-70; flange DN 50 PN 16;K DIN 931
3X M16 x 65 mm, PTFE-coated, flanges DN 50 PN 16
3A 5/8" x 83 mm;RF, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3B 5/8" x 83 mm;RF, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3C 5/8" x 95 mm;RTJ, mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs, ANSI B16.5
3D 5/8" x 95 mm;RTJ, mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs, ANSI B16.5
3T 5/8" x 83 mm;RF, mat.: PTFE coated, flange 2" 150 lbs
3V 5/8" x 95 mm;RTJ, mat.: PTFE coated, flange 2" 150 lbs
14. Additional bracket welded to the float pipe
0 without
H Bracket
15. Float pipe seamless
0 without
S 60,3 x 2 mm seamless; each 100 mm

34
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3 CR64 for cryogenic applications, vaporizing fluids
Float pipe and flanges material: 1.4571

Order codes for mag. Level Gauges type: ITA-3-Cryo

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
3C0501K1 16 Titanium 50,8 525 0,4017 N with spacers;
do not use for hydrogen or alcohol compounds
3C0501K2 16 Titanium 50,8 525 0,389 N with spacers;
do not use for hydrogen or alcohol compounds

For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

35
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.3.2 Order code scheme for ITA-3 Cryo

1. Type of level gauge ITA-3 CR64


2. C to C distance in mm [or inches]
3. Design
4. Armaflex insulation
5. C to C distance > 5000 mm
6. Process connection [side/side]
6.1 Surface side flanges
7. Side studs welded with T-pieces for 100 % X-ray-testing
8. Float removal flangeSurface float removal flange
8.1 Surface float removal flange
8.2 Bolts & nuts float removal flange
9. Drain plug

ITA-3-CR64

10. Additional drain flange, open


10.1 Surface open drain flange
11. Float pipe top end finish
11.1 Surface top end finish flange
11.2 Bolts and nuts rop end finish flange
12. Vent plug at top end
12.1 Vent flange welded to end cap instead of vent plug
12.2 Surface vent flange
13. Counter flanges
13.1 Surface counter flanges
13.2 Bolts & nuts counter flanges
14. Additional bracket welded to the float pipe
15. Float pipe seamless
16. Float

36
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.4.1 ITA-3.5

Characteristics: PN16 / Float pipe and flange material: 1.4404


(wetted parts E-CTFE-coated)

Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Additional bracket
2 c to c distance 10 Float pipe seamless
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Float
6 Float removal flange
7 Additional drain flange, open
8 Float pipe top end finish

37
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-3.5

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 3100 mm (one-part, total length max. 3500 mm)
> 3100 mm 2- or multipart
Pipe diameter: 60,3 x 2 mm welded
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 150#),
Welding or threaded stud
Drain/Vent connections: see order codes
Pipe material: 1.4404 (wetted parts E-CTFE coated)
Flange material: same as pipe material
Float material: Titanium/E-CTFE-coated
Operation temperature: -50..+160 °C
Operation pressure: max. 16 bar
Operation density: min. 0,5645 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket PTFE min -150 °C
Klingersil TOP Chem 2000
Indication rail: Aluminium
1.4301
Float types: Cylindical, sealed type
Length:
-270 mm
-130 mm
Standard dimensions: -A = 240 mm*
-B = 130 mm
Base equipment printed in bold letters!
*for densities < 1,0 kg/dm³ enlarge the scale A

38
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.4.2 Order codes ITA-3.5

Mag. Level Gauge


ITA-3.5 PN16/150 lbs
Float pipe and flange material 1.4404
wetted parts E-CTFE-coated (Halar)

Order codes for mag. level gauge type ITA- 3.5 PN16/150 lbs

Code Description

1. Float pipe welded


ITA-3.5
Dimensions 60,3 x 2 mm
2. c to c distance
L c to c distance in mm
3. Design
0 without indication rail each 100 mm
1 Indication rail material Aluminium max. 160 °C, each 100 mm
2 Indication rail material 1.4401 max. 160 °C, each 100 mm
4. c to c distance < 3100 mm, total length 3500 mm
A < 3100 mm - without flange connection; 1-part-constrution
B > 3100 mm - with flange connection; DN 50 PN 16 / 2"ANSI 150# (two or more parts construction)
5. Process connection side/side
1 Flanges DN 20 PN 16
2 Flanges DN 25 PN 16
3 Flanges DN 32 PN 16
4 Flanges DN 40 PN 16
5 Flanges DN 50 PN 16
A Flanges 3/4" ANSI 150 lbs
B Flanges 1" ANSI 150 lbs
C Flanges 1 1/4" ANSI 150 lbs
D Flanges 1 1/2" ANSI 150 lbs
E Flanges 2" ANSI 150 lbs
5.1 Surface side flanges
0 without
A Surface Form C
B Surface RF
6. Float removal flange
0 without
A Flange DN 50 PN 16 incl. blind flange
1 Flange 2" ANSI 150 lbs incl. blind flange
6.1 Surface side flanges
0 without
A Surface Form C
B Surface RF
6.2 Bolts & nuts float removal flange (bottom side)
0 without
63 M16 x 65 mm; mat. zinced steel; flange DN 32 PN 16; DIN 931
64 M16 x 65 mm; mat. A2-70; flange DN 32 PN 16; DIN 931
3X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 16
3A 5/8" x 83; mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs; ANSI B16.5
3B 5/8" x 83; mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs; ANSI B16.5
3T 5/8" x 83; mat. PTFE coated; flange 2" ANSI 150 lbs

39
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3.5 PN16/150 lbs
Float pipe and flange material 1.4404

Order codes for mag. level gauge type ITA- 3.5 PN16/150 lbs

Code Description

7. Additional drain flange, open


0 without
1 Drain stud with flange DN 20 PN 16
2 Drain stud with flange DN 25 PN 16
3 Drain stud with flange DN 32 PN 16
4 Drain stud with flange DN 40 PN 16
A Drain stud with flange 3/4" ANSI 150 lbs
B Drain stud with flange 1" ANSI 150 lbs
C Drain stud with flange 1 1/4" ANSI 150 lbs
D Drain stud with flange 1 1/2" ANSI 150 lbs
8. Float pipe top end finish
2 Flange with blind flange DN 50 PN 16
A Flange with blind flange 2" ANSI 150 lbs
8.1 Float pipe top end finish with concentric reducer (X-ray testing)
0 without
1 DN 20 PN 16
2 DN 25 PN 16
3 DN 32 PN 16
4 DN 40 PN 16
A 3/4" ANSI 150 lbs
B 1" ANSI 150 lbs
C 1 1/4" ANSI 150 lbs
D 1 1/2" ANSI 150 lbs
8.2 Surface float pipe top end finish flange (only DN50 or 2")
A Dichtleiste Form C
B Dichtleiste RF
8.3 Bolts & nuts float pipe top end finish flange (only DN50 or 2")
0 without
63 M16 x 65 mm; mat. zinced steel; flange DN 32 PN 16; DIN 931
64 M16 x 65 mm; mat. A2-70; flange DN 32 PN 16; DIN 931
3X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 16
3A 5/8" x 83; mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs; ANSI B16.5
3B 5/8" x 83; mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs; ANSI B16.5
3T 5/8" x 83; mat. PTFE coated; flange 2" ANSI 150 lbs
9.1 Vent flange with concentric reducer (X-ray testing)
0 without
1 DN 20 PN 16
2 DN 25 PN 16
3 DN 32 PN 16
4 DN 40 PN 16
A 3/4" ANSI 150 lbs
B 1" ANSI 150 lbs
C 1 1/4" ANSI 150 lbs
D 1 1/2" ANSI 150 lbs

40
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3.5 PN16/150 lbs
Float pipe and flange material 1.4404

Order codes for mag. level gauge type ITA- 3.5 PN16/150 lbs

Code Description

10. Additional bracket welded to the float pipe


0 without
H Bracket
11. Float pipe seamless
0 without
S 60,3 x 2 mm seamless; each 100 mm

41
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3.5 PN16/150 lbs
Float pipe and flanges material: 1.4404
wetted parts E-CTFE-coated (Halar)

Order codes for mag. Level Gauges type: ITA-3.5 PN16/150 lbs

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
35H024K1 16 Titanium, 52 240 0,6873 N
Halar-
coated
35H024K3 16 Titanium, 52 240 0,5645 N only with 316SS or Aluminium indication rail
Halar-
coated

For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

42
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.4.2 Order scheme ITA-3.5

1. Type of level gauge [ITA-3.5]


2. C to C distance in mm [or inches]
3. Design [Indication rail]
4. C to C distance > 3100 mm, total length 3500 mm
5. Process connection [side/side]
5.1 Surface side flanges
6. Float removal flange
6.1 Bolts & nuts float removal flange
7. Addisional drain flange, open

ITA-3.5

7.1 Drain flange with concentric reducer (X-ray testing)


7.2 Surface open drain flange
8. Float pipe top end finish
8.1 Float pipe top end finish with concentric reducer (X-ray testing)
8.2 Surface float pipe top end finish flange
8.3 Bolts & nuts float pipe top end finish flange
9. Vent flange welded to end cap instead of vent plug
9.1 Vent flange with concentric reducer (X-ray testing)
10. Additional bracket welded to the float pipe
11. Float pipe seamless
12. Float

43
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.5.1 ITA-3.8

Characteristics:
Float pipe and flange material 1.4404
wetted parts E-TFE-lined
applicable for vacuum service

Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Additional bracket
2 c to c distance 10 Float pipe seamless
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Float
6 Float removal flange
7 Additional drain flange, open
8 Float pipe top end finish

44
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-3.8

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 1700 mm (one-part, total length max. 2100 mm)
> 1700 mm 2- or multipart
Pipe diameter: 64 x 2 mm welded
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 150#),
Drain/Vent connections: see order codes
Pipe material: 1.4404 (wetted parts E-TFE lined)
Thickness of lining: min. 3,27 mm
Flange material: same as pipe material
Float material: Titanium/E-TFE-coated
Operation temperature: -50..+160 °C
Operation pressure: max. 16 bar / vacuum resistant
Operation density: min. 0,6873 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket PTFE up to 100 °C
Klingersil-chem-200 up to 260 °C
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type
Length:
-270 mm
-150 mm
Standard dimensions: -A = 240 mm*
-B = 130 mm
Base equipment printed in bold letters!
*for densities < 1,0 kg/dm³ enlarge the scale A

45
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.5.2 Order codes ITA-3.8

Mag. Level Gauge


ITA-3.8 PN16/150 lbs
Float pipe and flange material 1.4404
wetted parts E-TFE-lined
applicable for vacuum service

Order codes for mag. level gauges type ITA- 3 PN16/150 lbs

Code Description

1. Float pipe welded


ITA-3.8
Dimensions 64 x 2 mm
2. c to c distance
L c to c distance in mm
3. Design
0 without indication rail each 100 mm
1 Indication rail material: Makrolon, max. 120 °C, each 100 mm
2 Indication rail material: Aluminium max. 400 °C, each 100 mm
3 Indication rail material: 1.4401 max. 400 °C, each 100 mm
4. c to c distance < 1700 mm, total length 2100 mm
A < 1700 mm - without flange connection; one-part-construction
B > 1700 mm - with flange connection; DN 32 PN 16 (two or more parts construction)
5. Process connection side/side
1 Flanges DN 20 PN 16
2 Flanges DN 25 PN 16
3 Flanges DN 32 PN 16
4 Flanges DN 40 PN 16
5 Flanges DN 50 PN 16
A Flanges 3/4" ANSI 150 lbs
B Flanges 1" ANSI 150 lbs
C Flanges 1 1/4" ANSI 150 lbs
D Flanges 1 1/2" ANSI 150 lbs
E Flanges 2" ANSI 150 lbs
5.1 Surface side flanges
0 without
A Surface Form C
B Surface RF
6. Float removal flange
0 without
A Flange DN 50 PN 16 incl. blind flange
1 Flange 2" ANSI 150 lbs incl. blind flange
6.1 Surface Float removal flange (bottom side)
A Standard- Surface Form C
B Standard-Surface RF
6.2 Bolts & nuts float removal flange (bottom side)
0 without
63 M16 x 65 mm; mat. zinced steel; flange DN 32 PN 16; DIN 931
64 M16 x 65 mm; mat. A2-70; flange DN 32 PN 16; DIN 931
3X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 16
3A 5/8" x 83; mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs; ANSI B16.5
3B 5/8" x 83; mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs; ANSI B16.5
3T 5/8" x 83; mat. PTFE coated; flange 2" ANSI 150 lbs

46
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3.8 PN16/150 lbs
Float pipe and flange material 1.4404
wetted parts E-TFE-lined
applicable for vacuum service

Order codes for mag. level gauges type ITA- 3 PN16/150 lbs

Code Description

7. Additional drain flange, open


0 without
1 Drain stud with flange DN 20 PN 16
2 Drain stud with flange DN 25 PN 16
3 Drain stud with flange DN 32 PN 16
4 Drain stud with flange DN 40 PN 16
A Drain stud with flange 3/4" ANSI 150 lbs
B Drain stud with flange 1" ANSI 150 lbs
C Drain stud with flange 1 1/4" ANSI 150 lbs
D Drain stud with flange 1 1/2" ANSI 150 lbs
8. Vent flange welded to blind flange
0 without
1 Flanged DN 15 PN 16 (socket weld construction to blind flange)
2 Flanged DN 20 PN 16 (socket weld construction to blind flange)
3 Flanged DN 25 PN 16 (socket weld construction to blind flange)
4 Flanged DN 32 PN 16 (socket weld construction to blind flange)
5 Flanged DN 40 PN 16 (socket weld construction to blind flange)
6 Flanged DN 50 PN 16 (socket weld construction to blind flange)
A Flanged 1/2" ANSI 150 lbs (socket weld construction to blind flange)
B Flanged 3/4" ANSI 150 lbs (socket weld construction to blind flange)
C Flanged 1" ANSI 150 lbs (socket weld construction to blind flange)
D Flanged 1 1/4" ANSI 150 lbs (socket weld construction to blind flange)
E Flanged 1 1/2" ANSI 150 lbs (socket weld construction to blind flange)
F Flanged 2" ANSI 150 lbs (socket weld construction to blind flange)
8.1 Surface vent flange
0 without
A Standard- Surface Form C
B Standard-Surface RF
8.2 Bolts & Nuts vent flange
0 without
63 M16 x 65 mm; mat. zinced steel; flange DN 32 PN 16; DIN 931
64 M16 x 65 mm; mat. A2-70; flange DN 32 PN 16; DIN 931
3X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 16
3A 5/8" x 83; mat. zinced steel A193B7/A1942H; flange 2" ANSI 150 lbs; ANSI B16.5
3B 5/8" x 83; mat. stainless steel A193B8 A1948M; flange 2" ANSI 150 lbs; ANSI B16.5
3T 5/8" x 83; mat. PTFE coated; flange 2" ANSI 150 lbs
9. Additional bracket welded to the float pipe
0 without
H Bracket
10. Float pipe seamless
0 without
S 64 x 2 mm seamless; each 100 mm

47
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-3.8 PN16/150 lbs
Float pipe and flanges material: 1.4404
wetted parts ETFE-lined
applicable for vacuum service

Order codes for mag. Level Gauges type: ITA-3.5 PN16/150 lbs

Description
Floats
Code Pressure Material Diameter Length min. Density vented Notes
[bar] [mm] [mm] [kg/dm³] [Y/N]

34PVD1K1 10 PVDF 50 135 1,3000 N


34PVD2K1 10 PVDF 50 255 0,8500 N

For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

48
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.5.2 Order codes ITA-3.8

1. Type of Level Gauge [ITA-3.8]


2. C to C distance in mm [or inches]
3. Design [Indication rail]
4. C to C distance > 1700 mm, total length 2100 mm
5. Process connection [side/side]
5.1 Surface side flanges
6. Float removal flange
6.1 Surface float removal flange
6.2 Bolts & nuts float removal flange

ITA-3.8

7. Additional drain flange, open


7.1 Surface open drain flange
7.2 Bolts & nuts open drain flange
8. Vent flange welded to blind flange
8.1 Surface vent flange
8.2 Bolts & nuts vent flange
9. Additional bracket welded to the float pipe
10. Float pipe seamless
11. Float

49
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.6.1 ITA-4

Characteristics: PN16 / Float pipe and flange material: 1.4404


(mounted from top of tank)

Key:
1 Float pipe welded, dimensions 60,3 x 2 mm
2 Measuring length
3 Design (indication rail)
5 Process connection on tank
6 Follower magnet giude tube top side finish
7 Float with rod and follower magnet

50
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-4

Principle: Communicating tubes with magnetic float


Mounting position: Top of tank
Measuring range: max. 2750 mm
(depending on fluid's density)
Pipe diameter: 60,3 x 2 mm welded,
necking connections
Process connection: to specify:
Flanges DN50 PN 16 pr 2" 150#
Drain/Vent connections: Plug R1/2"
Pipe material: 1.4404; 1.4435; 1.4539; Hastelloy C4 (2.4610);
Inconel 625 (2.4856); Inconel 825 (2.4858);
Titan (3.7035) (other materials on request)
Flange material: same as pipe material
Float material: 1.4404
Titan, Titan/E-CTFE-coated
Operation temperature: -50..+400 °C
Operation pressure: max. 16 bar
Operation density: min. 0,68 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket PTFE up to 100 °C
Klingersil C4400 up to 175 °C
Graphit spiral wound up to 400 °C
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type, with rod
Base equipment printed in bold letters!

51
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.6.2 ITA-4.0

Characteristics: PN16 / Float pipe: 1.4404 and flanges : CS


(mounted from top of tank)

Key:
1 Float pipe welded, dimensions 60,3 x 2 mm
2 Measuring length
3 Design (indication rail)
5 Process connection on tank
6 Follower magnet giude tube top side finish
7 Float with rod and follower magnet

52
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-4.0

Principle: Communicating tubes with magnetic float


Mounting position: Top of tank
Measuring range: max. 2750 mm
(depending on fluid's density)
Pipe diameter: 60,3 x 2 mm welded,
necking connections
Process connection: to specify:
Flanges DN50 PN 16 pr 2" 150#
Drain/Vent connections: Plug R1/2"
Pipe material: 1.4404
Flange material: CS
Float material: 1.4404
Titan, Titan/E-CTFE-coated
Operation temperature: -50..+400 °C
Operation pressure: max. 16 bar
Operation density: min. 0,68 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket PTFE up to 100 °C
Klingersil C4400 up to 175 °C
Graphit spiral wound up to 400 °C
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type, with rod
Base equipment printed in bold letters!

53
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.6.3 Order Codes ITA-4 & ITA-4.0

Mag. Level Gauge


ITA-4 & ITA-4.0 PN16 / 150 lbs
mounted on top of tank

Order code for mag. level gauge type ITA-4 & ITA-4.0 PN 16 / 150 lbs

Code Description
ITA-4 1. Float pipe welded
Dimensions 60,3 x 2 mm
2. Measuring length
L Measuring lenght in mm ( max. 2750 mm, depending on the density of the fluid)
3. Design
0 without indication rail, each 100 mm
1 Indication rail material: Makrolon, max. 120 °C fluid temperature, each 100 mm
2 Indication rail material: Aluminium, max. 400 °C fluid temperature, each 100 mm
3 Indication rail material: 1.4401, max. 400 °C fluid temperature, each 100 mm
4. Two-parts-construction
0 without
1 Connection of the follower magnet guide tube DN50 PN16
2 Connection of the follower magnet guide tube 2" ANSI 150 lbs RF
5. Process connection on tank
1 Flange DN 50/PN 16
2 Flange DN 80/PN 16
3 Flange DN 100/PN 16
4 Flange DN 125/PN 16
5 Flange DN 150/PN 16
6 Flange DN 200/PN 16
A Flange 2" ANSI/150 lbs
B Flange 3" ANSI/150 lbs
C Flange 4" ANSI/150 lbs
D Flange 5" ANSI/150 lbs
E Flange 6" ANSI/150 lbs
F Flange 8" ANSI/150 lbs
5.1 Surface of the process connection on tank
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smouth finished)
F Surface groove (DIN 2512)
G Surface groove large
H Surface Feder (DIN 2512)
K Surface tongue-large

54
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-4 & ITA-4.0 PN16 / 150 lbs
mounted on top of tank

Order code for mag. level gauge type ITA-4 & ITA-4.0 PN 16 / 150 lbs

Code Description
6. Follower magnet guide tube topside finish
1 Flange with blind flange DN32 PN 16
2 Flange with blind flange DN50 PN 16
A Flange with blind flange 1 1/4" ANSI 150 lbs
B Flange with blind flange 2" ANSI 150 lbs
Floats
Code Pressure Material Diameter Length min. vented max. Notes
[bar] [mm] [mm] Density* [Y/N] rod length
[kg/dm³] [mm]
4V0240R1A 16 316L 52,0 265 0,9500 N 500
4V0240R1B 16 316L 52,0 265 1,0000 N 750
4T0240R1A 16 Titanium 50,8 265 0,6890 N 500 do not use with hydrogen or alcohol compounds
4T0240R1B 16 Titanium 50,8 265 0,7250 N 750 do not use with hydrogen or alcohol compounds
4T0240R1C 16 Titanium 50,8 265 0,7610 N 1000 do not use with hydrogen or alcohol compounds
4T0240R1D 16 Titanium 50,8 265 0,7970 N 1250 do not use with hydrogen or alcohol compounds
4T0240R1E 16 Titanium 50,8 265 0,8330 N 1500 do not use with hydrogen or alcohol compounds
4T0240R1F 16 Titanium 50,8 265 0,8690 N 1750 do not use with hydrogen or alcohol compounds
4T0240R1H 16 Titanium 50,8 265 0,9050 N 2000 do not use with hydrogen or alcohol compounds
4T0240K2A 16 Titanium 50,8 265 0,6480 N 500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K2B 16 Titanium 50,8 265 0,6840 N 750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K2C 16 Titanium 50,8 265 0,7200 N 1000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K2D 16 Titanium 50,8 265 0,7560 N 1250 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K2E 16 Titanium 50,8 265 0,7920 N 1500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K2F 16 Titanium 50,8 265 0,8280 N 1750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K2H 16 Titanium 50,8 265 0,8640 N 2000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3A 16 Titanium 50,8 265 0,5820 N 500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3B 16 Titanium 50,8 265 0,6810 N 750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3C 16 Titanium 50,8 265 0,6540 N 1000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3D 16 Titanium 50,8 265 0,6900 N 1250 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3E 16 Titanium 50,8 265 0,7260 N 1500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3F 16 Titanium 50,8 265 0,7620 N 1750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3H 16 Titanium 50,8 265 0,7980 N 2000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300R1A 16 Titanium 50,8 325 0,601 N 500 do not use with hydrogen or alcohol compounds
4T0300R1B 16 Titanium 50,8 325 0,629 N 750 do not use with hydrogen or alcohol compounds
4T0300R1C 16 Titanium 50,8 325 0,658 N 1000 do not use with hydrogen or alcohol compounds
4T0300R1D 16 Titanium 50,8 325 0,687 N 1250 do not use with hydrogen or alcohol compounds
4T0300R1E 16 Titanium 50,8 325 0,716 N 1500 do not use with hydrogen or alcohol compounds
4T0300R1F 16 Titanium 50,8 325 0,745 N 1750 do not use with hydrogen or alcohol compounds
4T0300R1H 16 Titanium 50,8 325 0,773 N 2000 do not use with hydrogen or alcohol compounds

55
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-4 & ITA-4.0 PN16 / 150 lbs
Mounted on top of tank

Order codes for mag. Level Gauges type: ITA-4 & ITA-4.0 PN16/150 lbs

Description
Floats
Code Pressure Material Diameter Length min. vented max. Notes
[bar] [mm] [mm] Density* [Y/N] rod length
[kg/dm³] [mm]
4T0300K2A 16 Titanium 50,8 325 0,568 N 500 do not use with hydrogen or alcohol compounds
4T0300K2B 16 Titanium 50,8 325 0,597 N 750 do not use with hydrogen or alcohol compounds
4T0300K2C 16 Titanium 50,8 325 0,625 N 1000 do not use with hydrogen or alcohol compounds
4T0300K2D 16 Titanium 50,8 325 0,654 N 1250 do not use with hydrogen or alcohol compounds
4T0300K2E 16 Titanium 50,8 325 0,683 N 1500 do not use with hydrogen or alcohol compounds
4T0300K2F 16 Titanium 50,8 325 0,712 N 1750 do not use with hydrogen or alcohol compounds
4T0300K2H 16 Titanium 50,8 325 0,741 N 2000 do not use with hydrogen or alcohol compounds
4T0300K3A 16 Titanium 50,8 325 0,5594 N 500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3B 16 Titanium 50,8 325 0,5594 N 750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3C 16 Titanium 50,8 325 0,5594 N 1000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3D 16 Titanium 50,8 325 0,5594 N 1250 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3E 16 Titanium 50,8 325 0,5594 N 1500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3F 16 Titanium 50,8 325 0,5594 N 1750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3H 16 Titanium 50,8 325 0,5594 N 2000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds

For additional accessories please refer to the chapters "Special Equipment" and "Electrical Accessories and Switches"
*The min. densities only are valid for temperature = 50 °C and rod dimensions 1000 mm (length) and 6 mm (diameter, standard).

56
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.6.3 Order Codes ITA-4 & ITA-4.0

1. Type of Level Gauge


2. Mesuring length in mm [or inches]
3. Design [Indication rail]
4. Two-parts construction
5. Process connection to tank
5.1 Surface of process connection flange
6. Follower magnet guide tube topside finish
7. Float

ITA-4

ITA-4.0

57
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.7.1 ITA-4.1

Characteristics: PN16 / Float pipe and flange material: 1.4404


(mounted from top of tank)

Key:
1 Float pipe welded, dimensions 88,9 x 2 mm
2 Measuring length
3 Design (indication rail)
5 Process connection on tank
6 Follower magnet giude tube top side finish
7 Float with rod and follower magnet

58
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-4.1

Principle: Communicating tubes with magnetic float


Mounting position: Top of tank
Measuring range: max. 2750 mm
(depending on fluid's density)
Pipe diameter: 88,9 x 2 mm welded,
necking connections
Process connection: to specify:
Flanges DN50 PN 16 pr 2" 150#
Drain/Vent connections: Plug R1/2"
Pipe material: 1.4404; 1.4435; 1.4539; Hastelloy C4 (2.4610);
Inconel 625 (2.4856); Inconel 825 (2.4858);
Titan (3.7035) (other materials on request)
Flange material: same as pipe material
Float material: 1.4404
Titan, Titan/E-CTFE-coated
Operation temperature: -50..+400 °C
Operation pressure: max. 16 bar
Operation density: min. 0,35 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket PTFE up to 100 °C
Klingersil C4400 up to 175 °C
Graphit spiral wound up to 400 °C
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type, with rod
Base equipment printed in bold letters!

59
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.7.2 ITA-4.1.0

Characteristics: PN16 / Float pipe: 1.4404 and flanges : CS


(mounted from top of tank)

Key:
1 Float pipe welded, dimensions 88,9 x 2 mm
2 Measuring length
3 Design (indication rail)
5 Process connection on tank
6 Follower magnet giude tube top side finish
7 Float with rod and follower magnet

60
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-4.1.0

Principle: Communicating tubes with magnetic float


Mounting position: Top of tank
Measuring range: max. 2750 mm
(depending on fluid's density)
Pipe diameter: 88,9 x 2 mm welded,
necking connections
Process connection: to specify:
Flanges DN50 PN 16 pr 2" 150#
Drain/Vent connections: Plug R1/2"
Pipe material: 1.4404
Flange material: CS
Float material: 1.4404
Titan, Titan/E-CTFE-coated
Operation temperature: -50..+400 °C
Operation pressure: max. 16 bar
Operation density: min. 0,35 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket PTFE up to 100 °C
Klingersil C4400 up to 175 °C
Graphit spiral wound up to 400 °C
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type, with rod
Base equipment printed in bold letters!

61
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.7.3 Order codes ITA-4.1 & ITA-4.1.0

Mag. Level Gauge


ITA-4.1 & ITA-4.1.0 PN16 / 150 lbs
mounted on top of tank

Order codes for mag. level gauge type ITA-4.1 & ITA-4.1.0 PN 16 / 150 lbs

Code Description
ITA-4.1 1. Float pipe welded
88,9 x 2 mm
2. Measuring length
L Measuring lenght in mm ( max. 2750 mm, depending on the density of the fluid)
3. Design
0 without indication rail, each 100 mm
1 Indication rail material: Makrolon, max. 120 °C fluid temperature, each 100 mm
2 Indication rail material: Aluminium, max. 400 °C fluid temperature, each 100 mm
3 Indication rail material: 1.4401, max. 400 °C fluid temperature, each 100 mm
4. Two-parts-construction
0 without
1 Connection of the follower magnet guide tube DN50 PN16
2 Connection of the follower magnet guide tube 2" ANSI 150 lbs RF
5. Process connection on tank
1 Flange DN 80/PN 16
2 Flange DN 100/PN 16
3 Flange DN 125/PN 16
4 Flange DN 150/PN 16
5 Flange DN 200/PN 16
A Flange 3" ANSI/150 lbs
B Flange 4" ANSI/150 lbs
C Flange 5" ANSI/150 lbs
D Flange 6" ANSI/150 lbs
E Flange 8" ANSI/150 lbs
5.1 Surface of the process connection on tank
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smouth finished)
F Surface groove (DIN 2512)
G Surface groove large
H Surface Feder (DIN 2512)
K Surface tongue-large

62
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-4.1 & ITA-4.1.0 PN16 / 150 lbs
mounted on top of tank

Order codes for mag. level gauge type ITA-4.1 & ITA-4.1.0 PN 16 / 150 lbs

Code Description
6. Follower magnet guide tube topside finish
1 Flange with blind flange DN32 PN 16
A Flange with blind flange 1 1/2" ANSI 150 lbs
7. Floats
Code Pressure Material Diameter Length min. vented max. Notes
[bar] [mm] [mm] Density* [Y/N] rod length
[kg/dm³] [mm]
4T0152R1A ATM Titanium 80 175 0,4070 N 500 do not use with hydrogen or alcohol compounds
4T0152R1B ATM Titanium 80 175 0,4310 N 750 do not use with hydrogen or alcohol compounds
4T0152R1C ATM Titanium 80 175 0,4540 N 1000 do not use with hydrogen or alcohol compounds
4T0152R1D ATM Titanium 80 175 0,4770 N 1250 do not use with hydrogen or alcohol compounds
4T0152R1E ATM Titanium 80 175 0,5000 N 1500 do not use with hydrogen or alcohol compounds
4T0152R1F ATM Titanium 80 175 0,5240 N 1750 do not use with hydrogen or alcohol compounds
4T0152R1H ATM Titanium 80 175 0,5470 N 2000 do not use with hydrogen or alcohol compounds
4T0152K2A ATM Titanium 80 175 0,4700 N 500 do not use with hydrogen or alcohol compounds
4T0152K2B ATM Titanium 80 175 0,4310 N 750 do not use with hydrogen or alcohol compounds
4T0152K2C ATM Titanium 80 175 0,4540 N 1000 do not use with hydrogen or alcohol compounds
4T0152K2D ATM Titanium 80 175 0,4770 N 1250 do not use with hydrogen or alcohol compounds
4T0152K2E ATM Titanium 80 175 0,5000 N 1500 do not use with hydrogen or alcohol compounds
4T0152K2F ATM Titanium 80 175 0,5240 N 1750 do not use with hydrogen or alcohol compounds
4T0152K2H ATM Titanium 80 175 0,5470 N 2000 do not use with hydrogen or alcohol compounds
4T0152K3A ATM Titanium 80 175 0,4710 N 500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3B ATM Titanium 80 175 0,4940 N 750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3C ATM Titanium 80 175 0,5180 N 1000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds

4T0152K3D ATM Titanium 80 175 0,5410 N 1250 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3E ATM Titanium 80 175 0,5640 N 1500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds

4T0152K3F ATM Titanium 80 175 0,5870 N 1750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3H ATM Titanium 80 175 0,6100 N 2000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds

4T0182R1A ATM Titanium 80 205 0,3620 N 500 do not use with hydrogen or alcohol compounds
4T0182R1B ATM Titanium 80 205 0,3810 N 750 do not use with hydrogen or alcohol compounds
4T0182R1C ATM Titanium 80 205 0,4000 N 1000 do not use with hydrogen or alcohol compounds
4T0182R1D ATM Titanium 80 205 0,4200 N 1250 do not use with hydrogen or alcohol compounds
4T0182R1E ATM Titanium 80 205 0,4390 N 1500 do not use with hydrogen or alcohol compounds
4T0182R1F ATM Titanium 80 205 0,4580 N 1750 do not use with hydrogen or alcohol compounds
4T0182R1H ATM Titanium 80 205 0,4780 N 2000 do not use with hydrogen or alcohol compounds
4T0182K2A ATM Titanium 80 205 0,3370 N 500 do not use with hydrogen or alcohol compounds
4T0182K2B ATM Titanium 80 205 0,3570 N 750 do not use with hydrogen or alcohol compounds
4T0182K2C ATM Titanium 80 205 0,3760 N 1000 do not use with hydrogen or alcohol compounds
4T0182K2D ATM Titanium 80 205 0,3950 N 1250 do not use with hydrogen or alcohol compounds
4T0182K2E ATM Titanium 80 205 0,4150 N 1500 do not use with hydrogen or alcohol compounds
4T0182K2F ATM Titanium 80 205 0,3430 N 1750 do not use with hydrogen or alcohol compounds
4T0182K2H ATM Titanium 80 205 0,4530 N 2000 do not use with hydrogen or alcohol compounds

63
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-4.1 & ITA-4.1.0 PN16 / 150 lbs
Mounted on top of tank

Order codes for mag. Level Gauges type: ITA-4.1 & ITA-4.1.0 PN16/150 lbs

Description
Floats
Code Pressure Material Diameter Length min. vented max. Notes
[bar] [mm] [mm] Density* [Y/N] rod length
[kg/dm³] [mm]
4T0182K3A ATM Titanium 80 205 0,3000 N 500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3B ATM Titanium 80 205 0,3190 N 750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3C ATM Titanium 80 205 0,3380 N 1000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3D ATM Titanium 80 205 0,3580 N 1250 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3E ATM Titanium 80 205 0,3770 N 1500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3F ATM Titanium 80 205 0,3960 N 1750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3H ATM Titanium 80 205 0,4160 N 2000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242R1A ATM Titanium 80 265 0,2980 N 500 do not use with hydrogen or alcohol compounds
4T0242R1B ATM Titanium 80 265 0,3120 N 750 do not use with hydrogen or alcohol compounds
4T0242R1C ATM Titanium 80 265 0,3270 N 1000 do not use with hydrogen or alcohol compounds
4T0242R1D ATM Titanium 80 265 0,3410 N 1250 do not use with hydrogen or alcohol compounds
4T0242R1E ATM Titanium 80 265 0,3560 N 1500 do not use with hydrogen or alcohol compounds
4T0242R1F ATM Titanium 80 265 0,3700 N 1750 do not use with hydrogen or alcohol compounds
4T0242R1H ATM Titanium 80 265 0,3850 N 2000 do not use with hydrogen or alcohol compounds
4T0242K2A ATM Titanium 80 265 0,2800 N 500 do not use with hydrogen or alcohol compounds
4T0242K2B ATM Titanium 80 265 0,2940 N 750 do not use with hydrogen or alcohol compounds
4T0242K2C ATM Titanium 80 265 0,3090 N 1000 do not use with hydrogen or alcohol compounds
4T0242K2D ATM Titanium 80 265 0,3230 N 1250 do not use with hydrogen or alcohol compounds
4T0242K2E ATM Titanium 80 265 0,3380 N 1500 do not use with hydrogen or alcohol compounds
4T0242K2F ATM Titanium 80 265 0,3520 N 1750 do not use with hydrogen or alcohol compounds
4T0242K2H ATM Titanium 80 265 0,3670 N 2000 do not use with hydrogen or alcohol compounds
4T0242K3A ATM Titanium 80 265 0,2530 N 500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds

4T0242K3B ATM Titanium 80 265 0,2680 N 750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds

4T0242K3C ATM Titanium 80 265 0,2820 N 1000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3D ATM Titanium 80 265 0,2970 N 1250 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3E ATM Titanium 80 265 0,3110 N 1500 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3F ATM Titanium 80 265 0,3260 N 1750 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds

4T0242K3H ATM Titanium 80 265 0,3400 N 2000 only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds

64
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-4.1 & ITA-4.1.0 PN16 / 150 lbs
Mounted on top of tank

Order codes for mag. Level Gauges type: ITA-4.1 & ITA-4.1.0 PN16/150 lbs

For additional accessories please refer to the chapters "Special Equipment" and "Electrical Accessories and Switches"
*The min. densities only are valid for temperature = 50 °C and rod dimensions 1000 mm (length) and 6 mm (diameter, standard).

65
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.7.3 Order Scheme ITA-4.1 & ITA-4.1.0

1. Type of level gauge [ITA-4.1 or ITA-4.1.0


2. Measuring length in mm [inches]
3. Design [Indication rail]
4. Two-parts-construction
5. Process connection on tank
5.1 Surface of process connection on tank
6. Follower magnet guide tube topside finish
7. Float

ITA-4.1

ITA-4.1.0

66
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.8.1 ITA-5

Characteristics: PN16 / Float pipe and flange material: 1.4404


(Process connections top/bottom)

Key:
1 Float pipe welded, dimensions 60,3 x 2 mm
2 Distance between process connections
3 Design (indication rail)
5 Process connection top side
6 Process connection bottom side
7 Float removal flange

67
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-5

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 2 mm welded,
2" Sch10
60,3 x 2…8,7 mm seamless
(depending on pressure rating)
Process connection: to specify:
R1/2" threaded (up to PN40)
Welding or threaded stud
Flanges DN15…50 (1/2"…2" 150#),
Pipe material: 1.4404; 1.4435; 1.4539; Hastelloy C4 (2.4610);
Inconel 625 (2.4856); Inconel 825 (2.4858);
Titan (3.7035) (other materials on request)
Flange material: same as pipe material
Float material: 1.4404
Titan, Titan/E-CTFE-coated
Operation temperature: -50..+400 °C
Operation pressure: max. 16 bar, up to 320 bar
Operation density: min. 0,3371 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket PTFE up to 100 °C
Klingersil C4400 up to 175 °C
Graphit spiral wound up to 400 °C**
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type or vented type
(Depending on pressure rating)
Standard dimensions: -A = 240 mm*
-B = 130 mm (up to PN64
- C = R1/2" (up to PN40)
1/2"NPT (all pressure ratings)
Base equipment printed in bold letters!
*depending on the density scale A can be enlarged

68
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.8.2 ITA-5.0

Characteristics: PN16 / Float pipe: 1.4404 and flanges : CS


(Process connections top/bottom)

Key:
1 Float pipe welded, dimensions 60,3 x 2 mm
2 Distance between process connections
3 Design (indication rail)
5 Process connection top side
6 Process connection bottom side
7 Float removal flange

69
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-5.0

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 2 mm welded,
2" Sch10
60,3 x 2…8,7 mm seamless
(depending on pressure rating)
Process connection: to specify:
R1/2" threaded (up to PN40)
Welding or threaded stud
Flanges DN15…50 (1/2"…2" 150#),
Pipe material: 1.4404 resp. 1.4571
Flange material: CS
Float material: 1.4404
Titan, Titan/E-CTFE-coated
Operation temperature: -50..+400 °C
Operation pressure: max. 16 bar, up to 320 bar
Operation density: min. 0,3371 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket PTFE up to 100 °C
Klingersil C4400 up to 175 °C
Graphit spiral wound up to 400 °C**
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type or vented type
(Depending on pressure rating)
Standard dimensions: -A = 240 mm*
-B = 130 mm (up to PN64
- C = R1/2" (up to PN40)
1/2"NPT (all pressure ratings)
Base equipment printed in bold letters!
*depending on the density scale A can be enlarged

70
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.8.3 Order codes ITA-5 & ITA-5.0

Mag. Level Gauge


ITA-5 & ITA-5.0 PN16/40 / 150 lbs/300 lbs*
without side studs, process connections topside/downside

Prices for mag. level gauge type ITA-5 & ITA- 5.0 PN 16/40 / 150 lbs/300 lbs*

Code Description
ITA-5 1. Float pipe welded
ITA-5.0 Dimensions 60,3x2 mm
2. Distance between process connections
L Distance between process connections in mm
3. Design
0 without indication rail each 100 mm
1 Indication rail material Makrolon, max. 120 °C, each 100 mm
2 Indication rail material Aluminium, max. 400 °C, each 100 mm
3 Indication rail material 1.4401, max. 400 °C, each 100 mm
4. Distance between process connections > 5000 mm
A Dist. betw. process connections < 5000 mm, without connection flanges
B Dist. betw. process connections > 5000 mm, with connection flanges DN 32 PN 16
5. Process connection topside
Y Welding connection (please specify)
Z Female thread (please specify)
1 Flange with blind flange DN 32 PN 16
5.1 Surface of process connection topside
0 without
A Standard-Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
5.2 Bolts & Nuts process connection topside
0 without
31 M16 x 65 mm; mat. zinced steel; flanges DN 32 PN 16; DIN 931
42 M16 x 65 mm; mat. A2-70; flanges DN 32 PN 16; DIN 931
63 M16 x 65 mm; mat. zinced steel; flanges DN 50 PN 16, DIN 931
64 M16 x 65 mm; mat. A2-70; flanges DN 50 PN 16; DIN 931
3X M16 x 65 mm; mat. PTFE-coated; flanges DN 50 PN 16
3Z M16 x 80 mm; mat. PTFE-coated; flanges DN 50 PN 16
41 M16 x 65 mm; mat. zinced steel; flanges DN 32 PN 40; DIN 931

71
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-5 & ITA-5.0 PN16/40 / 150 lbs/300 lbs*
without side studs, process connections topside/downside

Prices for mag. level gauge type ITA-5 & ITA- 5.0 PN 16/40 / 150 lbs/300 lbs*

Code Description
5.2 Bolts & Nuts process connection topside (Continuation)
32 M16 x 65 mm; mat. A2-70; flanges DN 32 PN 40; DIN 931
43 M16 x 80 mm; mat. zinced steel; flanges DN 32 PN 40, DIN 2510
44 M16 x 80 mm; mat. A2-70; flanges DN 32 PN 40; DIN 2510
65 M16 x 65 mm; mat. zinced steel; flanges DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. A2-70; flanges DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. zinced steel; flanges DN 50 PN 40, DIN 2510
68 M16 x 80 mm; mat. A2-70; flanges DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flanges DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flanges DN 50 PN 40
5.2 Bolts & Nuts process connection topside (Continuation)
3A 5/8 x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" 150 lbs; ANSI B 16.5
3B 5/8 x 83 mm; RF; mat. A193B8/A1948M SS; flange 2" 150 lbs; ANSI B 16.5
3C 5/8 x 95 mm; RTJ; mat. A193B7/A1942H zinced steel; flange 2" 150 lbs; ANSI B 16.5
3D 5/8 x 95 mm; RTJ; mat. A193B8/A1948M SS; flange 2" 150 lbs; ANSI B 16.5
3T 5/8 x 83 mm; RF; mat. PTFE-coated; flange 2" 150 lbs; ANSI B 16.5
3V 5/8 x 95 mm; RTJ; mat. PTFE-coated; flange 2" 150 lbs; ANSI B 16.5
FA 5/8 x 89 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" 300 lbs; ANSI B 16.5
FB 5/8 x 89 mm; RF; mat. A193B8/A1948M SS; flange 2" 300 lbs; ANSI B 16.5
FC 5/8 x 102 mm; RTJ; mat. A193B7/A1942H zinced steel; flange 2" 300 lbs; ANSI B 16.5
FD 5/8 x 102 mm; RTJ; mat. A193B8/A1948M SS; flange 2" 300 lbs; ANSI B 16.5
FT 5/8 x 89 mm; RF; mat. PTFE-coated; flange 2" 300 lbs; ANSI B 16.5
FV 5/8 x 102 mm; RTJ; mat. PTFE-coated; flange 2" 300 lbs; ANSI B 16.5
6. Process connection bottom side
Y Welding connection (please specify)
Z Female thread (please specify)
A Flange with blind flange DN 50 PN 16
6.1 Surface of process connection bottom side
0 without
A Standard-Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large

72
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-5 & ITA-5.0 PN16/40 / 150 lbs/300 lbs*
without side studs, process connections topside/downside

Prices for mag. level gauge type ITA-5 & ITA- 5.0 PN 16/40 / 150 lbs/300 lbs*

Code Description
6.2 Bolts & Nuts process connection bottom side
0 without
31 M16 x 65 mm; mat. zinced steel; flanges DN 32 PN 16; DIN 931
42 M16 x 65 mm; mat. A2-70; flanges DN 32 PN 16; DIN 931
63 M16 x 65 mm; mat. zinced steel; flanges DN 50 PN 16, DIN 931
64 M16 x 65 mm; mat. A2-70; flanges DN 50 PN 16; DIN 931
3X M16 x 65 mm; mat. PTFE-coated; flanges DN 50 PN 16
3Z M16 x 80 mm; mat. PTFE-coated; flanges DN 50 PN 16
41 M16 x 65 mm; mat. zinced steel; flanges DN 32 PN 40; DIN 931
32 M16 x 65 mm; mat. A2-70; flanges DN 32 PN 40; DIN 931
43 M16 x 80 mm; mat. zinced steel; flanges DN 32 PN 40, DIN 2510
44 M16 x 80 mm; mat. A2-70; flanges DN 32 PN 40; DIN 2510
65 M16 x 65 mm; mat. zinced steel; flanges DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. A2-70; flanges DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. zinced steel; flanges DN 50 PN 40, DIN 2510
68 M16 x 80 mm; mat. A2-70; flanges DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flanges DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flanges DN 50 PN 40
3A 5/8 x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" 150 lbs; ANSI B 16.5
3A 5/8 x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" 150 lbs; ANSI B 16.5
3B 5/8 x 83 mm; RF; mat. A193B8/A1948M SS; flange 2" 150 lbs; ANSI B 16.5
3C 5/8 x 95 mm; RTJ; mat. A193B7/A1942H zinced steel; flange 2" 150 lbs; ANSI B 16.5
3D 5/8 x 95 mm; RTJ; mat. A193B8/A1948M SS; flange 2" 150 lbs; ANSI B 16.5
3T 5/8 x 83 mm; RF; mat. PTFE-coated; flange 2" 150 lbs; ANSI B 16.5
3V 5/8 x 95 mm; RTJ; mat. PTFE-coated; flange 2" 150 lbs; ANSI B 16.5
FA 5/8 x 89 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" 300 lbs; ANSI B 16.5
FB 5/8 x 89 mm; RF; mat. A193B8/A1948M SS; flange 2" 300 lbs; ANSI B 16.5
FC 5/8 x 102 mm; RTJ; mat. A193B7/A1942H zinced steel; flange 2" 300 lbs; ANSI B 16.5
FD 5/8 x 102 mm; RTJ; mat. A193B8/A1948M SS; flange 2" 300 lbs; ANSI B 16.5
FT 5/8 x 89 mm; RF; mat. PTFE-coated; flange 2" 300 lbs; ANSI B 16.5
FV 5/8 x 102 mm; RTJ; mat. PTFE-coated; flange 2" 300 lbs; ANSI B 16.5
For additional accessories please go to the chapters "Special equipment" and "Electrical accessories and Switches"
*for higher pressure ratings please see ITA-10 to ITA-13

73
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-5 & ITA-5.0 PN16/150 lbs

Order codes for mag. Level Gauges type: ITA-5 & ITA-5.0 PN16/150 lbs

Description
Floats
Code Pressur Material Diameter Length min. vented Notes
e [mm] [mm] Density [Y/N]
[bar] [kg/dm³]
3V0100K1 16 316L 52 125 1,4907 N
3V0100K3 16 316L 52 125 1,0524 N only with 316SS or Aluminium indication rail
3V0120K1 16 316L 52 145 1,2346 N
3V0120K3 16 316L 52 145 0,9034 N only with 316SS or Aluminium indication rail
3V0150K1 16 316L 52 175 0,9905 N
3V0150K3 16 316L 52 175 0,8606 N only with 316SS or Aluminium indication rail
3V0180K1 16 316L 52 205 0,8781 N
3V0180K3 16 316L 52 205 0,7022 N only with 316SS or Aluminium indication rail
3V0240K1 16 316L 52 265 0,7374 N
3V0240K3 16 316L 52 265 0,6209 N only with 316SS or Aluminium indication rail
3V1240K1 40 316L 52 265 1,000 N
3T0100K1 16 Titanium 50,8 125 1,1788 N do not use with hydrogen or alcohol compounds
3T0100K3 16 Titanium 50,8 125 0,7821 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0120K1 16 Titanium 50,8 145 0,9646 N do not use with hydrogen or alcohol compounds
3T0120K3 16 Titanium 50,8 145 0,6514 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0150K1 16 Titanium 50,8 175 0,7763 N do not use with hydrogen or alcohol compounds
3T0150K3 16 Titanium 50,8 175 0,5675 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0180K1 16 Titanium 50,8 205 0,6716 N do not use with hydrogen or alcohol compounds
3T0180K3 16 Titanium 50,8 205 0,5094 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0240K1 16 Titanium 50,8 265 0,5723 N do not use with hydrogen or alcohol compounds
3T0240K3 16 Titanium 50,8 265 0,4550 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0300K1 16 Titanium 50,8 325 0,4955 N do not use with hydrogen or alcohol compounds
3T0300K3 16 Titanium 50,8 325 0,4063 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0400K1 16 Titanium 50,8 425 0,4358 N do not use with hydrogen or alcohol compounds
3T0400K3 16 Titanium 50,8 425 0,3719 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0500K1 16 Titanium 50,8 525 0,4017 N do not use with hydrogen or alcohol compounds
3T0500K3 16 Titanium 50,8 525 0,3539 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0600K1 16 Titanium 50,8 625 0,3761 N do not use with hydrogen or alcohol compounds
3T0600K3 16 Titanium 50,8 625 0,3371 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3H0150K1 16 Titanium, 52 175 0,902 N
Halar-coated
3HC012K1 16 Hastelloy C4 52 175 1,2455 N
3HC024K1 16 Hastelloy C4 52 265 0,7510 N
3HC024K3 16 Hastelloy C4 52 265 0,6296 N only with 316SS or Aluminium indication rail

NOTE: The prices for the single parts in the above price list are only meant for the composition of a complete level gauge.
For spare parts prices, please refer to the chapter "Spare parts".
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"
FOR HIGHER PRESSURE RATINGS, PLEASE SEE ITA-6 TO ITA-13!

74
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.8.3 Order scheme ITA-5 & ITA-5.0

1. Type of level gauge [ITA-5 or ITA-5.0]


2. Distance between process connections in mm [or inches]
3. Design [Indication rail]
4 Distance between process connections > 5000 mm
5. Process connection top side
5.1 Surface process connection top side
5.2 Bolts & nuts process connection top side
6. Process connection bottom side
6.1 Surface process connection bottom side
6.2 Bolts & nuts process connection bottom side
7. Floats

ITA-5

ITA-5.0

75
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.9.1 ITA-6

Characteristics: PN40 / Float pipe and flange material: 1.4404

Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug

76
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-6

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 2 mm welded,
60,3 x 2 mm seamless
2" Sch10
necking connection or buttweld with T-pieces
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 300#),
Welding or threaded stud
Drain/Vent connections: Plug R1/2" (for more please see order codes)
Pipe material: 1.4404; 1.4435; 1.4539; Hastelloy C4 (2.4610);
Inconel 625 (2.4856); Inconel 825 (2.4858);
Titan (3.7035) (other materials on request)
Flange material: same as pipe material
Float material: 1.4404
Titan, Titan/E-CTFE-coated
Operation temperature: -50..+400 °C
Operation pressure: max. 40 bar
Operation density: min. 0,5723 kg/dm³ up to 20 bar process pressure
min. 0,4370 kg/dm³ up to 40 bar process pressure
Viscosity: max. 5000 mPa s
Bolts & Nuts: A193/A194 B7/2H
A193/A194 B8/8M
CS hot dipped galvanized
SS
Gasket PTFE up to 100 °C
Klingersil C4400 up to 175 °C
Graphit spiral wound up to 400 °C**
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type
Length:
-270 mm
-130 mm
-150 mm
-210 mm
-330 mm
-430 mm
-530 mm
-630 mm
Standard dimensions: -A = 240 mm*
-B = 130 mm
- C = 40 mm
Base equipment printed in bold letters!
*for densities < 0,5723 kg/dm³ enlarge the scale A
**only with vent- and/or drain flanges DN50 resp. 2"

77
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.9.2 ITA-6.0

Characteristics: PN40 / Float pipe: 1.4404 and flanges : CS

Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug

78
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-6.0

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 2 mm welded,
60,3 x 2 mm seamless
2" Sch10
necking connection or buttweld with T-pieces
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 300#),
Welding or threaded stud
Drain/Vent connections: Plug R1/2" (for more please see order codes)
Pipe material: 1.4404
Flange material: CS
Float material: 1.4404
Titan, Titan/E-CTFE-coated
Operation temperature: -50..+400 °C
Operation pressure: max. 40 bar
Operation density: min. 0,5723 kg/dm³ up to 20 bar process pressure
min. 0,4370 kg/dm³ up to 40 bar process pressure
Viscosity: max. 5000 mPa s
Bolts & Nuts: A193/A194 B7/2H
A193/A194 B8/8M
CS hot dipped galvanized
SS
Gasket PTFE up to 100 °C
Klingersil C4400 up to 175 °C
Graphit spiral wound up to 400 °C**
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type
Length:
-270 mm
-130 mm
-150 mm
-210 mm
-330 mm
-430 mm
-530 mm
-630 mm
Standard dimensions: -A = 240 mm*
-B = 130 mm
- C = 40 mm
Base equipment printed in bold letters!
*for densities < 0,5723 kg/dm³ enlarge the scale A
**only with vent- and/or drain flanges DN50 resp. 2"

79
3.9.3 Pressure-Temperature Table ITA-6 (Float pipe)

80
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.9.4 Order codes ITA-6 & ITA-6.0

Mag. Level Gauge


ITA-6 & ITA-6.0 PN40/300 lbs

Order codes for mag. level gauge type ITA-6 & ITA-6.0 PN40/300 lbs

Code Description

ITA-6 1. Float pipe welded


ITA-6.0 Dimensions 60,3 x 2 mm
2. c to c distance
L c to c distance in mm
3. Design
0 without indication rail each 100 mm
1 Indication rail material: Makrolon max. 120 °C; each 100 mm
2 Indication rail material: Aluminium max. 400 °C, pro 100 mm
3 Indication rail material: 1.4401 max. 400 °C, pro 100 mm
4. c to c distance < 5000 mm
A < 5000 mm - without flange connection; DN 32 PN 40
B > 5000 mm - with flange connection; DN 32 PN 40
5. Process connection side/side
Y Welding connection (please specify)
Z Threaded connection (please specify)
1 Flanges DN 15 PN 40
2 Flanges DN 20 PN 40
3 Flanges DN 25 PN 40
4 Flanges DN 32 PN 40
5 Flanges DN 40 PN 40
6 Flanges DN 50 PN 40
A Flanges 1/2" ANSI 300 lbs
B Flanges 3/4" ANSI 300 lbs
C Flanges 1" ANSI 300 lbs
D Flanges 1 1/4" ANSI 300 lbs
E Flanges 1 1/2" ANSI 300 lbs
F Flanges 2" ANSI 300 lbs
5.1 Surface side flanges
0 without
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface Nut (DIN2512)
G Surface groove large
H Surface Feder (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
6. Side studs welded with T-pieces for 100 % X-ray testing
0 without
T T-pieces

81
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-6 & ITA-6.0 PN40/300 lbs

Order codes for mag. level gauge type ITA-6 & ITA-6.0 PN40/300 lbs

Code Description

7. Float removal flange (bottom side)


1 End cap (only if float removal flange (top side))
2 Flange DN 32 PN 40 incl. blind flange
3 Flange DN 50 PN 40 incl. blind flange
A Flange 2" ANSI 300 lbs incl. blind flange
4 Flange DN 50 PN 40 prepared for shut off valve on side
B Flange 2" ANSI 300 lbs prepared for shut off valve on side
7.1 Surface float removal flange (bottom side) (only DN50 or 2")
0 without (Float removal flange (bottom side) = end cap or < DN50 or 2")
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
7.2 Bolts & Nuts float removal flange
0 without (Float removal flange (bottom side) = end cap)
41 M16 x 65 mm; mat. CS zinced; flange DN 32 PN 40; DIN 931
42 M16 x 65 mm; mat. SS 1.4301; flange DN 32 PN 40; DIN 931
43 M16 x 80 mm; mat. CS zinced; flange DN 32 PN 40; DIN 2510
44 M16 x 80 mm; mat. SS 1.4301; flange DN 32 PN 40; DIN 2510
65 M16 x 65 mm; mat. CS zinced; flange DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. CS zinced; flange DN 50 PN 40; DIN 2510
68 M16 x 80 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flange DN 50 PN 40
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5
8. Drain plug
0 without
1 Drain plug G 1/2" with soft iron gasket
2 Drain plug 1/2" NPT
3 Drain plug 3/4" NPT
4 Drain plug 1" NPT

82
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-6 & ITA-6.0 PN40/300 lbs

Order codes for mag. level gauge type ITA-6 & ITA-6.0 PN40/300 lbs

Code Description

9. Additional drain flange, open


0 without
1 Drain stud with flange DN 15 PN 40
2 Drain stud with flange DN 20 PN 40
3 Drain stud with flange DN 25 PN 40
4 Drain stud with flange DN 32 PN 40
5 Drain stud with flange DN 40 PN 40
A Drain stud with flange 1/2" ANSI 300 lbs
B Drain stud with flange 3/4" ANSI 300 lbs
C Drain stud with flange 1" ANSI 300 lbs
D Drain stud with flange 1 1/4" ANSI 300 lbs
E Drain stud with flange 1 1/2" ANSI 300 lbs
9.1 Drain flange with concentric reducer (X-ray testing)
0 without
1 DN 15 PN 40
2 DN 20 PN 40
3 DN 25 PN 40
4 DN 32 PN 40
5 DN 40 PN 40
A 1/2" ANSI 300 lbs
B 3/4" ANSI 300 lbs
C 1" ANSI 300 lbs
D 1 1/4" ANSI 300 lbs
E 1 1/2" ANSI 300 lbs
9.2 Surface open drain flange
0 without (Float removal flange (bottom side) = end cap or < DN50 or 2")
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
10. Float pipe top end finish
1 End cap
2 Flange with blind flange DN 32 PN 40
3 Flange with blind flange DN 50 PN 40
4 Flange with blind flange 2" ANSI 300 lbs
10.1 Surface float pipe top end finish flange (only DN50 or 2")
0 without (Float pipe top end finish = End cap or < DN50 or 2")
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16

83
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-6 & ITA-6.0 PN40/300 lbs

Order codes for mag. level gauge type ITA-6 & ITA-6.0 PN40/300 lbs

Code Description

10.1 Surface float pipe top end finish flange (only DN50 or 2") (Continuation)
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
10.2 Bolts & nuts float pipe top end finish flange
0 without (Float removal flange (bottom side) = end cap)
41 M16 x 65 mm; mat. CS zinced; flange DN 32 PN 40; DIN 931
42 M16 x 65 mm; mat. SS 1.4301; flange DN 32 PN 40; DIN 931
43 M16 x 80 mm; mat. CS zinced; flange DN 32 PN 40; DIN 2510
44 M16 x 80 mm; mat. SS 1.4301; flange DN 32 PN 40; DIN 2510
65 M16 x 65 mm; mat. CS zinced; flange DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. CS zinced; flange DN 50 PN 40; DIN 2510
68 M16 x 80 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flange DN 50 PN 40
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5
11. Vent plug at top end
0 without
1 Vent plug G 1/2" with soft iron gasket
2 Vent plug 1/2" NPT
3 Vent plug 3/4" NPT
4 Vent plug 1" NPT
11.1 Vent flange welded to end cap instead of vent plug
0 without
1 Flanged DN 15 PN 40 (socket weld construction to endcap)
2 Flanged DN 20 PN 40 (socket weld construction to endcap)
3 Flanged DN 25 PN 40 (socket weld construction to endcap)
4 Flanged DN 32 PN 40 (socket weld construction to endcap)
5 Flanged DN 40 PN 40 (socket weld construction to endcap)
6 Flanged DN 50 PN 40 (socket weld construction to endcap)
A Flanged 1/2" ANSI 300 lbs (socket weld construction to endcap)
B Flanged 3/4" ANSI 300 lbs (socket weld construction to endcap)
C Flanged 1" ANSI 300 lbs (socket weld construction to endcap)
D Flanged 1 1/4" ANSI 300 lbs (socket weld construction to endcap)
E Flanged 1 1/2" ANSI 300 lbs (socket weld construction to endcap)
F Flanged 2" ANSI 300 lbs (socket weld construction to endcap)

84
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-6 & ITA-6.0 PN40/300 lbs

Order codes for mag. level gauge type ITA-6 & ITA-6.0 PN40/300 lbs

Code Description

11.2 Vent flange with concentric reducer (X-ray testing)


0 without
1 DN 15 PN 40
2 DN 20 PN 40
3 DN 25 PN 40
4 DN 32 PN 40
5 DN 40 PN 40
A 1/2" ANSI 300 lbs
B 3/4" ANSI 300 lbs
C 1" ANSI 300 lbs
D 1 1/4" ANSI 300 lbs
E 1 1/2" ANSI 300 lbs
11.3 Surface vent flange welded to end cap (only DN50 or 2")
0 without (Vent flange welded to end cap = without)
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
12. Counter flanges
0 without
1 DN 15 PN 40
2 DN 20 PN 40
3 DN 25 PN 40
4 DN 32 PN 40
5 DN 40 PN 40
6 DN 50 PN 40
A 1/2" 300 lbs
B 3/4" 300 lbs
C 1" 300 lbs
D 1 1/4" 300 lbs
E 1 1/2" 300 lbs
F 2" 300 lbs
12.1 Surface counter flanges
0 without
A Standard- Surface Form C
B Standard-Surface RF
C Surface Form D Rz=40
D Surface Form E Rz=16
E Surface RFSF (smooth finished)

85
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-6 & ITA-6.0 PN40/300 lbs

Order codes for mag. level gauge type ITA-6 & ITA-6.0 PN40/300 lbs

Code Description

12.1 Surface counter flanges (Continuation)


F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
12.2 Bolts & Nuts counter flanges
0 without (Float removal flange (bottom side) = end cap)
41 M16 x 65 mm; mat. CS zinced; flange DN 32 PN 40; DIN 931
42 M16 x 65 mm; mat. SS 1.4301; flange DN 32 PN 40; DIN 931
43 M16 x 80 mm; mat. CS zinced; flange DN 32 PN 40; DIN 2510
44 M16 x 80 mm; mat. SS 1.4301; flange DN 32 PN 40; DIN 2510
65 M16 x 65 mm; mat. CS zinced; flange DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. CS zinced; flange DN 50 PN 40; DIN 2510
68 M16 x 80 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flange DN 50 PN 40
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5
13. Additional bracket welded to the float pipe
0 without
H Bracket
14. Float pipe seamless
0 without
S 60,3 x 2 mm seamless; each 100 mm
For additional accessories please go to the chapters "Special equipment" and "Electrical accessories and Switches"

86
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-6 & ITA-6.0 PN40/300 lbs
Float pipe and flanges material: 1.4404

Order codes for mag. Level Gauges type: ITA-6 & ITA-6.0 PN40/300 lbs

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
6V0100K1 30 316L 52 125 1,5188 N
6V0100K3 30 316L 52 125 1,0891 N only with 316SS or Aluminium indication rail
6V0120K1 30 316L 52 145 1,2780 N
6V0120K3 30 316L 52 145 0,9519 N only with 316SS or Aluminium indication rail
6V0150K1 30 316L 52 175 1,0711 N
6V0150K3 30 316L 52 175 0,8309 N only with 316SS or Aluminium indication rail
6V0180K1 30 316L 52 205 0,9486 N
6V0180K3 30 316L 52 205 0,8140 N only with 316SS or Aluminium indication rail
6V0240K1 30 316L 52 265 0,7738 N
6V0240K3 30 316L 52 265 0,6513 N only with 316SS or Aluminium indication rail
6T0100K1 40 Titanium 50,8 125 1,3114 N do not use for hydrogen and alcohol compounds
6T0100K3 40 Titanium 50,8 125 0,8975 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds

6T0120K1 40 Titanium 50,8 145 1,1007 N do not use for hydrogen and alcohol compounds
6T0120K3 40 Titanium 50,8 145 0,7837 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds

6T0150K1 40 Titanium 50,8 175 0,9029 N do not use for hydrogen and alcohol compounds
6T0150K3 40 Titanium 50,8 175 0,6763 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds
6T0180K1 40 Titanium 50,8 205 0,7791 N do not use for hydrogen and alcohol compounds
6T0180K3 40 Titanium 50,8 205 0,6100 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds
6T0240K1 40 Titanium 50,8 265 0,6391 N do not use for hydrogen and alcohol compounds
6T0240K3 40 Titanium 50,8 265 0,5187 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds
6T0300K1 40 Titanium 50,8 325 0,5694 N do not use for hydrogen and alcohol compounds
6T0300K3 40 Titanium 50,8 325 0,4812 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds
6T0400K1 40 Titanium 50,8 425 0,5300 N do not use for hydrogen and alcohol compounds
6T0400K3 40 Titanium 50,8 425 0,4373 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds
6T0500K1 40 Titanium 50,8 525 0,4463 N do not use for hydrogen and alcohol compounds
6T0500K3 40 Titanium 50,8 525 0,4098 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds
6T0600K1 40 Titanium 50,8 625 0,4370 N do not use for hydrogen and alcohol compounds
6T0600K3 40 Titanium 50,8 625 0,3834 N only with 316SS or Aluminium indication rail
do not use for hydrogen and alcohol compounds

6H0200K1 40 Titanium, 52 265 0,7674 N


Halar-coated
6H0200K1 40 Titanium, 52 265 0,6470 N only with 316SS or Aluminium indication rail
Halar-coated
6HC012K1 40 Hastelloy C4 52 145 N
6HC024K1 40 Hastelloy C4 52 265 N
6HC024K3 40 Hastelloy C4 52 265 N only with 316SS or Aluminium indication rail

For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

87
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.9.4 Order code scheme for ITA-6 & ITA-6.0

1. Type of level gauge ITA-6 or ITA-6.0


2. C to C distance in mm [or inches]
3. Design
4. C to C distance > 5000 mm
5. Process connection [side/side]
5.1 Surface side flanges
6. Side studs welded with T-pieces for 100 % X-ray-testing
7. Float removal flange
7.1 Surface float removal flange
7.2 Bolts & nuts float removal flange
8. Drain plug
9. Additional drain flange, open

ITA-6

ITA-6.0

9.1 Drain flange with concentric reducer (X-ray testing)


9.2 Surface open drain flange
10. Float pipe top end finish
10.1 Surface top end finish flange
10.2 Bolts and nuts rop end finish flange
11. Vent plug at top end
11.1 Vent flange welded to end cap instead of vent plug
11.2 Vent flange with concentric reducer (X-ray testing)
11.3 Surface vent flange welded to end cap
12. Counter flanges
12.1 Surface counter flanges
12.2 Bolts & nuts counter flanges
13. Additional bracket welded to the float pipe
14. Float pipe seamless
15. Float

88
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.10.1 ITA-6 Cryo for cryogenic applications, non-vaporizing fluids

Characteristics: PN16 / Float pipe and flange material: 1.4404

Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Drain plug
2 c to c distance 10 Additional drain flange, open
3 Design (indication rail) 11 Float pipe top end finish
4 Armaflex£ insulation 12 Vent plug
6 Process connection side/side 13 Counter flanges
7 Side studs welded with T pieces 14 Additional bracket
for 100 % X-ray testing 15 Float pipe seamless
8 Float removal flange 16 Float

89
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-6 Cryo

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 2 mm welded
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 300#),
Drain/Vent connections: Plug R1/2" (for more please see order codes)
Pipe material: 1.4404; 1.4435; 1.4539; Hastelloy C4 (2.4610);
Inconel 625 (2.4856); Inconel 825 (2.4858);
Titan (3.7035) (other materials on request)
Flange material: same as pipe material
Float material: 1.4404
Titan, Titan/E-CTFE-coated
Operation temperature: -200..+100 °C
Operation pressure: max. 40 bar
Operation density: min. 0,4693 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS (min. -10°C)
SS or material in acc. with DIN 17280
Gasket PTFE min -150 °C
Klingersil TOP Chem 2000
Indication rail: Aluminium
1.4301
Float types: Cylindical, sealed type
Dimensions:
- ‡50,8 x 270 mm*
Standard dimensions: A = 240 mm*
B = 130 mm
C = 40 mm

Base equipment printed in bold letters!


*not for vaporizing media (e.g. ammonia)

90
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.10.2 Order codes ITA-6 Cryo

Mag. Level Gauge


ITA-6-Cryo for cryogenic applications
non-vaporizing fluids
Order codes for mag. level gauge type ITA-6-Cryo for cryogenic applications

Code Description

1. Float pipe welded


ITA-6-Cryo
Dimensions 60,3 x 2 mm
2. c to c distance
L c to c distance in mm
3. Design
0 without indication rail each 100 mm
1 Indication rail material: Aluminium max. 400 °C, pro 100 mm
2 Indication rail material: 1.4401 max. 400 °C, pro 100 mm
4. Armaflex-Insulation
0 without Armaflex insulation
F Thickness: 12 mm, bis -15 °C
R Thickness: 30 mm, bis -50 °C
T Thickness: 70 mm, bis -200 °C incl. Makrolon window
5. C to C distance < 5000 mm
A < 5000 mm - without flange connection; DN 32 PN 40
B > 5000 mm - with flange connection; DN 32 PN 40
6. Process connection side/side
Y Welding connection (please specify)
Z Threaded connection (please specify)
1 Flanges DN 15 PN 40
2 Flanges DN 20 PN 40
3 Flanges DN 25 PN 40
4 Flanges DN 32 PN 40
5 Flanges DN 40 PN 40
6 Flanges DN 50 PN 40
A Flanges 1/2" ANSI 300 lbs
B Flanges 3/4" ANSI 300 lbs
C Flanges 1" ANSI 300 lbs
D Flanges 1 1/4" ANSI 300 lbs
E Flanges 1 1/2" ANSI 300 lbs
F Flanges 2" ANSI 300 lbs
6.1 Surface side flanges
0 without
F Groove (DIN2512)
H Tongue (DIN2512)
7. Side studs welded with T-pieces for 100 % X-ray testing
0 without
T T-pieces
8. Float removal flange (bottom side)
1 End cap (only if float removal flange (top side))
2 Flange DN 50 PN 40 incl. blind flange
3 Flange 2" ANSI 300 lbs incl. blind flange

91
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-6-Cryo for cryogenic applications
non-vaporizing fluids
Order codes for mag. level gauge type ITA-6-Cryo for cryogenic applications

Code Description

8.1 Surface float removal flange (bottom side) (only DN50 or 2")
0 without (Float removal flange (bottom side) = end cap or < DN50 or 2")
F Groove (DIN2512)
H Tongue (DIN2512)
8.2 Bolts & Nuts float removal flange
0 without (Float removal flange (bottom side) = end cap)
65 M16 x 65 mm; mat. CS zinced; flange DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. CS zinced; flange DN 50 PN 40; DIN 2510
68 M16 x 80 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flange DN 50 PN 40
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5
9. Drain plug
0 without
1 G 1/2" DIN1910
10. Float pipe top end finish
1 End cap
2 Flange with blind flange DN 50 PN 40
A Flange with blind flange 2" ANSI 300 lbs
10.1 Surface float pipe top end finish flange (only DN50 or 2")
0 without (Float pipe top end finish = End cap or < DN50 or 2")
F Groove (DIN2512)
H Tongue (DIN2512)
10.2 Bolts & nuts float pipe top end finish flange
0 without (Float pipe top end = end cap)
65 M16 x 65 mm; mat. CS zinced; flange DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. CS zinced; flange DN 50 PN 40; DIN 2510
68 M16 x 80 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flange DN 50 PN 40
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5
11. Vent plug on topside
0 without
1 Vent plug G 1/2" with soft iron gasket

92
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-6-Cryo for cryogenic applications
non-vaporizing fluids
Order codes for mag. level gauge type ITA-6-Cryo for cryogenic applications

Code Description

12. Counter flanges


0 without
1 DN 15 PN 40
2 DN 20 PN 40
3 DN 25 PN 40
4 DN 32 PN 40
5 DN 40 PN 40
6 DN 50 PN 40
A 1/2" 300 lbs
B 3/4" 300 lbs
C 1" 300 lbs
D 1 1/4" 300 lbs
E 1 1/2" 300 lbs
F 2" 300 lbs
12.1 Surface counter flanges
0 without
F Groove (DIN2512)
H Tongue (DIN2512)
12.2 Bolts & Nuts counter flanges
0 without
65 M16 x 65 mm; mat. CS zinced; flange DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. CS zinced; flange DN 50 PN 40; DIN 2510
68 M16 x 80 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flange DN 50 PN 40
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5
13. Additional bracket welded to the float pipe
0 without
H Bracket
14. Float pipe seamless
0 without
S 60,3 x 2 mm seamless; each 100 mm

93
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-6-Cryo for cryogenic applications
Float pipe and flanges material: 1.4404

Order codees for mag. Level Gauges type: ITA-6-Cryo for cryogenic applications

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
6C0240K1 40 Titanium 50,8 265 0,6391 N without spacers;
do not use with alcohol or hydrogen compounds
6C0400K1 40 Titanium 45 425 0,5981 N with spacers;
do not use with alcohol or hydrogen compounds
6C0500K3 40 Titanium 45 525 0,5486 N with spacers;
only with Aluminium or SS indication rail;
do not use with alcohol or hydrogen compounds

For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

94
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.10.2 Order code scheme for ITA-3 Cryo

1. Type of level gauge ITA-3 Cryo


2. C to C distance in mm [or inches]
3. Design
4. Armaflex insulation
5. C to C distance > 5000 mm
6. Process connection [side/side]
6.1 Surface side flanges
7. Side studs welded with T-pieces for 100 % X-ray-testing
8. Float removal flangeSurface float removal flange
8.1 Surface float removal flange
8.2 Bolts & nuts float removal flange
9. Drain plug

ITA-3-Cryo

10.Float pipe top end finish


10.1 Surface top end finish flange
11. Vent plug at top end
12. Counter flanges
12.1 Surface counter flanges
12.2 Bolts & nuts counter flanges
12.1 Vent flange welded to end cap instead of vent plug
12.2 Surface vent flange
13. Additional bracket welded to the float pipe
14. Float pipe seamless
15. Float

95
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.11.1 ITA-6 CR64 for cryogenic applications, vaporizing fluid

Characteristics: PN40 / Float pipe and flange material: 1.4571

Key:
1 Float pipe welded, dimensions 64 x 2 mm 9 Drain plug
2 c to c distance 10 Additional drain flange, open
3 Design (indication rail) 11 Float pipe top end finish
4 Armaflex insulation 12 Vent plug
6 Process connection side/side 13 Counter flanges
7 Side studs welded with T pieces 14 Additional bracket
for 100 % X-ray testing 15 Float pipe seamless
8 Float removal flange 16 Float

96
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-6 CR64

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 64 x 2 mm welded,
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 300#),
Welding or threaded stud
Drain/Vent connections: Plug G1/2" (for more please see order codes)
Pipe material: 1.4571; 1.4435; 1.4539; Hastelloy C4 (2.4610);
Inconel 625 (2.4856); Inconel 825 (2.4858);
Titan (3.7035) (other materials on request)
Flange material: same as pipe material
Float material: Titan, Titan/E-CTFE-coated

Operation temperature: -200..+100 °C


Operation pressure: max. 40 bar
Operation density: min. 0,4693 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS (min. -10°C)
SS or material in acc. with DIN 17280
Gasket PTFE min -150 °C
Klingersil TOP Chem 2000
Indication rail: Aluminium
1.4301
Float types: Cylindical, sealed type
Length:
-∅50,8 x 270 mm*
-∅50,8 x 530 mm
Standard dimensions: A = 240 mm*
B = 130 mm
C = 40 mm

Base equipment printed in bold letters!


*not for vaporizing media (e.g. ammonia)

97
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.11.2 Order codes ITA-6 CR64

Mag. Level Gauge


ITA-6-CR64 for cryogenic applications, vaporizing fluid (e.g. ammonia)
Float pipe and flange material: 1.4571

Order codes for mag. level gauge type ITA-6-CR64 for cryogenic applications

Code Description

1. Float pipe welded


ITA-3-CR64
Dimensions 64 x 2 mm
2. c to c distance
L c to c distance in mm
3. Design
0 without indication rail each 100 mm
1 Indication rail material: Aluminium max. 400 °C, pro 100 mm
2 Indication rail material: 1.4401 max. 400 °C, pro 100 mm
4. Armaflex-Insulation
0 without Armaflex insulation
F Thickness: 12 mm, bis -15 °C
R Thickness: 30 mm, bis -50 °C
T Thickness: 70 mm, bis -200 °C incl. Makrolon window
5. C to C distance < 5000 mm
A < 5000 mm - without flange connection; DN 32 PN 40
B > 5000 mm - with flange connection; DN 32 PN 40
6. Process connection side/side
Y Welding connection (please specify)
Z Threaded connection (please specify)
1 Flanges DN 15 PN 40
2 Flanges DN 20 PN 40
3 Flanges DN 25 PN 40
4 Flanges DN 32 PN 40
5 Flanges DN 40 PN 40
6 Flanges DN 50 PN 40
A Flanges 1/2" ANSI 300 lbs
B Flanges 3/4" ANSI 300 lbs
C Flanges 1" ANSI 300 lbs
D Flanges 1 1/4" ANSI 300 lbs
E Flanges 1 1/2" ANSI 300 lbs
F Flanges 2" ANSI 300 lbs
6.1 Surface side flanges
0 without
F Groove (DIN2512)
H Tongue (DIN2512)
7. Side studs welded with T-pieces for 100 % X-ray testing
0 without
T T-pieces
8. Float removal flange (bottom side)
1 End cap (only if float removal flange (top side))
2 Flange DN 50 PN 40 incl. blind flange
A Flange 2" ANSI 300 lbs incl. blind flange

98
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-6-CR64 for cryogenic applications, vaporizing fluid (e.g. ammonia)
Float pipe and flange material: 1.4571

Order codes for mag. level gauge type ITA-6-CR64 for cryogenic applications

Code Description

8.1 Surface float removal flange (bottom side) (only DN50 or 2")
0 without (Float removal flange (bottom side) = end cap or < DN50 or 2")
F Groove (DIN2512)
H Tongue (DIN2512)
8.2 Bolts & Nuts float removal flange
0 without (Float removal flange (bottom side) = end cap)
65 M16 x 65 mm; mat. CS zinced; flange DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. CS zinced; flange DN 50 PN 40; DIN 2510
68 M16 x 80 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flange DN 50 PN 40
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5
9. Drain plug
0 without
1 G 1/2" DIN1910
10. Float pipe top end finish
1 End cap
2 Flange with blind flange DN 50 PN 40
A Flange with blind flange 2" ANSI 300 lbs
10.1 Surface float pipe top end finish flange (only DN50 or 2")
0 without (Float pipe top end finish = End cap or < DN50 or 2")
F Groove (DIN2512)
H Tongue (DIN2512)
10.2 Bolts & nuts float pipe top end finish flange
0 without (Float pipe top end = end cap)
65 M16 x 65 mm; mat. CS zinced; flange DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. CS zinced; flange DN 50 PN 40; DIN 2510
68 M16 x 80 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flange DN 50 PN 40
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5

99
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-6-CR64 for cryogenic applications, vaporizing fluid (e.g. ammonia)
Float pipe and flange material: 1.4571

Order codes for mag. level gauge type ITA-6-CR64 for cryogenic applications

Code Description

11. Vent plug on topside


0 without
1 Vent plug G 1/2" with soft iron gasket
12. Counter flanges
0 without
1 DN 15 PN 40
2 DN 20 PN 40
3 DN 25 PN 40
4 DN 32 PN 40
5 DN 40 PN 40
6 DN 50 PN 40
A 1/2" 300 lbs
B 3/4" 300 lbs
C 1" 300 lbs
D 1 1/4" 300 lbs
E 1 1/2" 300 lbs
F 2" 300 lbs
12.1 Surface counter flanges
0 without
F Groove (DIN2512)
H Tongue (DIN2512)
12.2 Bolts & Nuts counter flanges
0 without
65 M16 x 65 mm; mat. CS zinced; flange DN 50 PN 40; DIN 931
66 M16 x 65 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 931
67 M16 x 80 mm; mat. CS zinced; flange DN 50 PN 40; DIN 2510
68 M16 x 80 mm; mat. SS 1.4301; flange DN 50 PN 40; DIN 2510
6X M16 x 65 mm; mat. PTFE-coated; flange DN 50 PN 40
6Z M16 x 80 mm; mat. PTFE-coated; flange DN 50 PN 40
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5
13. Additional bracket welded to the float pipe
0 without
H Bracket
14. Float pipe seamless
0 without
S 60,3 x 2 mm seamless; each 100 mm

100
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-6-CR64 for cryogenic applications, vaporizing fluid (e.g. ammonia)
Float pipe and flange material: 1.4571

Order codes for mag. Level Gauges type: ITA-6-CR64 for cryogenic applications

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
6C0240K1 40 Titanium 50,8 265 0,6391 N without spacers;
do not use with alcohol or hydrogen compounds
6C0500K1 40 Titanium 45 525 0,5981 N with spacers;
do not use with alcohol or hydrogen compounds

For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

101
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.11.2 Order code scheme for ITA-3 Cryo

1. Type of level gauge ITA-3 Cryo


2. C to C distance in mm [or inches]
3. Design
4. Armaflex insulation
5. C to C distance > 5000 mm
6. Process connection [side/side]
6.1 Surface side flanges
7. Side studs welded with T-pieces for 100 % X-ray-testing
8. Float removal flangeSurface float removal flange
8.1 Surface float removal flange
8.2 Bolts & nuts float removal flange
9. Drain plug

ITA-3-Cryo

10.Float pipe top end finish


10.1 Surface top end finish flange
11. Vent plug at top end
12. Counter flanges
12.1 Surface counter flanges
12.2 Bolts & nuts counter flanges
12.1 Vent flange welded to end cap instead of vent plug
12.2 Surface vent flange
13. Additional bracket welded to the float pipe
14. Float pipe seamless
15. Float

102
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.12.1 ITA-7

Characteristics: PN64 / Float pipe and flange material: 1.4571

Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug

103
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-7

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 2 mm welded,
butt-weld connection wie T-pieces
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 300#),
Welding or threaded stud
Drain/Vent connections: Plug 1/2"NPT
Pipe material: 1.4571; 1.4404; 1.4435; 1.4539;
Hastelloy C4 (2.4610); Inconel 625 (2.4856);
Inconel 825 (2.4858);Titan (3.7035)
(other materials on request)
Flange material: same as pipe material
Float material: Titanium**, Titan/E-CTFE-coated
Operation temperature: -50..+400 °C
Operation pressure: max. 64 bar
Operation density: min. 0,4243 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket Spiral wound, 316Ti
Cam profile, 316Ti
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type
Length:
-270 mm
-330 mm
-530 mm
-630 mm
Standard dimensions: -A = 240 mm*
-B = 130 mm
- C = 40 mm
Base equipment printed in bold letters!
*for densities < 0,4243 kg/dm³ enlarge the scale A
**not for use for hydrogen or alcohol-compounds

104
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.12.2 ITA-7.0

Characteristics: PN64 / Float pipe: 1.4571 and flanges : CS

Key:
1 Float pipe welded, dimensions 60,3 x 2 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

105

Technical specifications magnetic level gauge type ITA-7.0

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 2 mm welded,
butt-weld connection wie T-pieces
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 300#),
Welding or threaded stud
Drain/Vent connections: Plug 1/2"NPT
Pipe material: 1.4571
Flange material: CS
Float material: Titanium**, Titan/E-CTFE-coated
Operation temperature: -50..+400 °C
Operation pressure: max. 64 bar
Operation density: min. 0,4243 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket Spiral wound, 316Ti
Cam profile, 316Ti
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type
Length:
-270 mm
-330 mm
-530 mm
-630 mm
Standard dimensions: -A = 240 mm*
-B = 130 mm
- C = 40 mm
Base equipment printed in bold letters!
*for densities < 0,4243 kg/dm³ enlarge the scale A
**not for use for hydrogen or alcohol-compounds

106
3.12.3 Pressure-Temperature Table ITA-7 (Float pipe)

107
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.12.4 Order codes ITA-7 & ITA-7.0

Mag. Level Gauge


ITA-7 & ITA-7.0 PN64/300 lbs

Prices for mag. level gauge type ITA- 7 & ITA-7.0 PN64/300 lbs

Code Description

ITA-7.0 1. Float pipe seamless


Dimensions 60,3 x 2,9 mm
2. c to c distance
L c to c distance in mm
3. Design
0 without indication rail each 100 mm
1 Indication rail material: Makrolon max. 120 °C; each 100 mm
2 Indication rail material: Aluminium max. 400 °C, pro 100 mm
3 Indication rail material: 1.4401 max. 400 °C, pro 100 mm
4. c to c distance < 5000 mm
A < 5000 mm - without flange connection; DN 50 PN 63
B > 5000 mm - with flange connection; DN 50 PN 63
5. Process connection side/side
Y Welding connection (please specify)
Z Threaded connection (please specify)
1 Flanges DN 15 PN 63
2 Flanges DN 20 PN 63
3 Flanges DN 25 PN 63
4 Flanges DN 32 PN 63
5 Flanges DN 40 PN 63
6 Flanges DN 50 PN 63
A Flanges 1/2" ANSI 300 lbs
B Flanges 3/4" ANSI 300 lbs
C Flanges 1" ANSI 300 lbs
D Flanges 1 1/4" ANSI 300 lbs
E Flanges 1 1/2" ANSI 300 lbs
F Flanges 2" ANSI 300 lbs
5.1 Surface side flanges
0 without
A Standard- Surface Form C
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface Nut (DIN2512)
G Surface groove large
H Surface Feder (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
6. Side studs welded with T-pieces for 100 % X-ray testing
0 without
T T-pieces

108
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-7 & ITA-7.0 PN64/300 lbs

Prices for mag. level gauge type ITA- 7 & ITA-7.0 PN64/300 lbs

Code Description

7. Float removal flange (bottom side)


1 End cap (only if float removal flange (top side))
2 Flange DN 50 PN 63 incl. blind flange
A Flange 2" ANSI 300 lbs incl. blind flange
3 Flange DN 50 PN 63 prepared for shut off valve on side
B Flange 2" ANSI 300 lbs prepared for shut off valve on side
7.1 Surface float removal flange (bottom side) (only DN50 or 2")
0 without (Float removal flange (bottom side) = end cap or < DN50 or 2")
A Standard- Surface Form C
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
7.2 Bolts & Nuts float removal flange
0 without (Float removal flange (bottom side) = end cap)
61 M20 x 80 mm; mat. steel zinced; Flange DN 50 PN 63
62 M20 x 80 mm; mat. SS 1.4301; Flange DN 50 PN 63
63 M20 x 110 mm; mat. steel zinced; Flange 2510 DN50 PN63
64 M22 x 100 mm; mat. SS 1.4301; Flange DIN 2510 DN 50 PN 63
6X 5/8" x 89 mm; mat. steel zinced A193B7 / A1942H; Flange 2" ANSI 300 lbs
6Z 5/8" x 89 mm; mat. SS A193B8 A1948M; Flange 2" ANSI 300 lbs
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5
8. Drain plug
0 without
1 Drain plug 1/2" NPT
2 Drain plug 3/4" NPT
3 Drain plug 1" NPT
9. Additional drain flange, open
0 without
1 Drain stud with flange DN 15 PN 63
2 Drain stud with flange DN 20 PN 63
3 Drain stud with flange DN 25 PN 63
4 Drain stud with flange DN 32 PN 63
5 Drain stud with flange DN 40 PN 63
A Drain stud with flange 1/2" ANSI 300 lbs
B Drain stud with flange 3/4" ANSI 300 lbs
C Drain stud with flange 1" ANSI 300 lbs
D Drain stud with flange 1 1/4" ANSI 300 lbs
E Drain stud with flange 1 1/2" ANSI 300 lbs

109
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-7 & ITA-7.0 PN64/300 lbs

Prices for mag. level gauge type ITA- 7 & ITA-7.0 PN64/300 lbs

Code Description

9.1 Drain flange with concentric reducer (X-ray testing)


0 ohne
1 DN 15 PN 63
2 DN 20 PN 63
3 DN 25 PN 63
4 DN 32 PN 63
5 DN 40 PN 63
A 1/2" ANSI 300 lbs
B 3/4" ANSI 300 lbs
C 1" ANSI 300 lbs
D 1 1/4" ANSI 300 lbs
E 1 1/2" ANSI 300 lbs
9.2 Surface open drain flange
0 without (Float removal flange (bottom side) = end cap or < DN50 or 2")
A Standard- Surface Form C
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
10. Float pipe top end finish
1 End cap
2 Flange with blind flange DN 50 PN 63
A Flange with blind flange 2" ANSI 300 lbs
10.1 Surface float pipe top end finish flange (only DN50 or 2")
0 without (Float pipe top end finish = End cap or < DN50 or 2")
A Standard- Surface Form C
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
10.2 Bolts & nuts float pipe top end finish flange
0 without (Float pipe top end = end cap)
61 M20 x 80 mm; mat. steel zinced; Flange DN 50 PN 63
62 M20 x 80 mm; mat. SS 1.4301; Flange DN 50 PN 63
63 M20 x 110 mm; mat. steel zinced; Flange 2510 DN50 PN63
64 M22 x 100 mm; mat. SS 1.4301; Flange DIN 2510 DN 50 PN 63
6X 5/8" x 89 mm; mat. steel zinced A193B7 / A1942H; Flange 2" ANSI 300 lbs
6Z 5/8" x 89 mm; mat. SS A193B8 A1948M; Flange 2" ANSI 300 lbs

110
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-7 & ITA-7.0 PN64/300 lbs

Prices for mag. level gauge type ITA- 7 & ITA-7.0 PN64/300 lbs

Code Description

10.2 Bolts & nuts float pipe top end finish flange (Continuation)
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5
11. Vent plug at top end
0 without
1 Vent plug G 1/2" DIN910
2 Vent plug 1/2" NPT
3 Vent plug 3/4" NPT
4 Vent plug 1" NPT
11.1 Vent flange welded to end cap instead of vent plug
0 without
1 Flange DN 15 PN 63 (socket weld construction to endcap)
2 Flange DN 20 PN 63 (socket weld construction to end cap)
3 Flange DN 25 PN 63 (socket weld construction to end cap)
4 Flange DN 32 PN 63 (socket weld construction to end cap)
5 Flange DN 40 PN 63 (socket weld construction to end cap)
A Flange 1/2" ANSI 300 lbs (socket weld construction to end cap)
B Flange 3/4" ANSI 300 lbs (socket weld construction to end cap)
C Flange 1" ANSI 300 lbs (socket weld construction to end cap)
D Flange 1 1/4" ANSI 300 lbs (socket weld construction to end cap)
E Flange 1 1/2" ANSI 300 lbs (socket weld construction to end cap)
11.2 Vent flange with concentric reducer (X-ray testing)
0 without
1 DN 15 PN 63
2 DN 20 PN 63
3 DN 25 PN 63
4 DN 32 PN 63
5 DN 40 PN 63
A 1/2" ANSI 300 lbs
B 3/4" ANSI 300 lbs
C 1" ANSI 300 lbs
D 1 1/4" ANSI 300 lbs
E 1 1/2" ANSI 300 lbs
11.3 Surface vent flange welded to end cap (only DN50 or 2")
0 without (Vent flange welded to end cap = without)
A Standard- Surface Form C
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"

111
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-7 & ITA-7.0 PN64/300 lbs

Prices for mag. level gauge type ITA- 7 & ITA-7.0 PN64/300 lbs

Code Description

12. Counter flanges


0 without
1 DN 15 PN 63
2 DN 20 PN 63
3 DN 25 PN 63
4 DN 32 PN 63
5 DN 40 PN 63
6 DN 50 PN 63
A 1/2" ANSI 300 lbs
B 3/4" ANSI 300 lbs
C 1" ANSI 300 lbs
D 1 1/4" ANSI 300 lbs
E 1 1/2" ANSI 300 lbs
F 2" ANSI 300 lbs
12.1 Surface counter flanges
0 without (Counter flanges = without)
A Standard- Surface Form C
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI) 1/2" bis 2"
12.2 Bolts & Nuts counter flanges
0 without (Counter flanges = without)
61 M20 x 80 mm; mat. steel zinced; Flange DN 50 PN 63
62 M20 x 80 mm; mat. SS 1.4301; Flange DN 50 PN 63
63 M20 x 110 mm; mat. steel zinced; Flange 2510 DN50 PN63
64 M22 x 100 mm; mat. SS 1.4301; Flange DIN 2510 DN 50 PN 63
6X 5/8" x 89 mm; mat. steel zinced A193B7 / A1942H; Flange 2" ANSI 300 lbs
6Z 5/8" x 89 mm; mat. SS A193B8 A1948M; Flange 2" ANSI 300 lbs
FA 5/8" x 83 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 300 lbs, ANSI B16.5
FB 5/8" x 89 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FC 5/8" x 102 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 300 lbs; ANSI B16.5
FD 5/8" x 102 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 300 lbs, ANSI B16.5
FT 5/8" x 89 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 300 lbs, ANSI B16.5
FV 5/8" x 102 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 300 lbs; ANSI B16.5
13. Additional bracket welded to the float pipe
0 without
H Bracket

112
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-7 & ITA-7.0 PN64/300 lbs

Order codes for mag. Level Gauges type: ITA-7 PN64/300 lbs

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
7T0240K1 64 Titanium 50,8 265 0,6820 N do not use with alcohol or hydrogen compounds
7T0240K3 64 Titanium 50,8 265 0,5551 N only with 316SS or Aluminium indication rail;
do not use with alcohol or hydrogen compounds
7T0300K1 64 Titanium 50,8 325 0,6064 N do not use with alcohol or hydrogen compounds
7T0300K3 64 Titanium 50,8 325 0,5168 N only with 316SS or Aluminium indication rail;
do not use with alcohol or hydrogen compounds
7T0500K3 64 Titanium 50,8 525 0,4450 N only with 316SS or Aluminium indication rail;
do not use with alcohol or hydrogen compounds
7T0600K3 64 Titanium 50,8 625 0,4243 N only with 316SS or Aluminium indication rail;
do not use with alcohol or hydrogen compounds

For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

113
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.12.4 Order code scheme for ITA-7 & ITA-7.0

1. Type of level gauge ITA-7 or ITA-7.0


2. C to C distance in mm [or inches]
3. Design
4. C to C distance > 5000 mm
5. Process connection [side/side]
5.1 Surface side flanges
6. Side studs welded with T-pieces for 100 % X-ray-testing
7. Float removal flange
7.1 Surface float removal flange
7.2 Bolts & nuts float removal flange
8. Drain plug
9. Additional drain flange, open

ITA-7

ITA-7.0

9.1 Drain flange with concentric reducer (X-ray testing)


9.2 Surface open drain flange
10. Float pipe top end finish
10.1 Surface top end finish flange
10.2 Bolts and nuts rop end finish flange
11. Vent plug at top end
11.1 Vent flange welded to end cap instead of vent plug
11.2 Vent flange with concentric reducer (X-ray testing)
11.3 Surface vent flange welded to end cap
12. Counter flanges
12.1 Surface counter flanges
12.2 Bolts & nuts counter flanges
13. Additional bracket welded to the float pipe
14. Float

114
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.13.1 ITA-8.1 [PVC]

Characteristics: PN6 / Material: PVC

Key:
1 Float pipe PVC, dimensions 63 x 47 mm
2 c to c distance
3 Design (indication rail)
6 Process connection side/side
7 Drain plug
8 Float pipe top end finish
9 Mounting link
10 Float

115
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-8.1

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 63 x 4,7 mm
Process connection: to specify:
Flanges DN15…50 (1/2"…2")
Drain/Vent connections: Plug R1/2" (for more please see order codes)
Pipe material: PVC
Flange material: same as pipe material
Float material: PVC
Operation temperature: -30..+60 °C
Operation pressure: max. 6 bar
Operation density: min. 0,75 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: SS
Gasket Viton
Indication rail: Aluminium
1.4301
Float types: Cylindical, sealed type
Length:
- 255 mm
- 135 mm
Standard dimensions: A = 240 mm*
B = 130 mm
C = 110 mm

Base equipment printed in bold letters!


*for densities < 0,75 kg/dm³ enlarge scale A

116
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.13.2 Order codes ITA-8.1 (PVC)

Mag. Level Gauge


ITA-8.1 PN6 (PVC)
Float pipe and flange material PVC

Order codes for mag. level gauge type ITA-8.1 PN6 (PVC)

Code Description
ITA-8.1 1. Float pipe PVC
Dimensions 63 x 4,7 mm
2. C to C distance
L C to C distance in mm
3. Design
0 without indication rail, each 100 mm
1 Indication rail material Aluminium, max. 60 °C liquid temperature, each 100 mm
2 Indication rail material 1.4401, max. 60 °C liquid temperature, each 100 mm
4. C to C distance < 5000 mm
A < 5000 without flange connection DN 32 PN 6
B > 5000 with flange connection DN32 PN 6
5. Reinforcement
0 without reinforcement
Reinforcement of the PVC-guide tube, material: 1.4404, base price
A
+ length dependent price each 100 mm guide tube
6. Process connections side/side
Y Welding connection (please specify)
Z Threaded connection (please specify)
1 Flanges DN 15 PN 6
2 Flanges DN 15 PN 10
3 Flanges DN 20 PN 6
4 Flanges DN 20 PN 10
5 Flanges DN 25 PN 6
6 Flanges DN 25 PN 10
7 Flanges DN 32 PN 6
8 Flanges DN 32 PN 10
9 Flanges DN 40 PN 6
A Flanges DN 40 PN 10
B Flanges DN 50 PN 6
C Flanges DN 50 PN 10
D Flanges 1/2" ANSI 150 lbs
E Flanges 3/4" ANSI 150 lbs
F Flanges 1" ANSI 150 lbs
G Flanges 1 1/4" ANSI 150 lbs
H Flanges 1 1/2" ANSI 150 lbs
K Flanges 2" ANSI 150 lbs
7. Drain plug
0 without
1 Drain plug R1/2"
2 Drain plug 1/2" NPT
3 Drain plug 3/4" NPT
4 Stud on blind flange

117
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-8.1 PN6 (PVC)
Float pipe and flange material PVC

Order codes for mag. level gauge type ITA-8.1 PN6 (PVC)

Code Description
8. Float pipe top end finish
0 without
A End cap
B Vent plug R1/2"
C Vent plug 1/2" NPT
D Vent plug 3/4" NPT
E Flange DN32 PN6
8.1 Nuts & bolts top end finish flange
0 without
1 M8 x 60 mm; mat. SS 1.4301; DIN 931
9. Mounting link for additional fixing on the tank
0 without
H Mounting link for additional fixing on the tank
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
8PVC01K1 10 PVC 50 135 1,1500 N only with 316SS or Aluminium indication rail
8PVC02K1 10 PVC 50 255 0,7500 N only with 316SS or Aluminium indication rail

For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

118
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.13.2 Order scheme for ITA-8.1

1. Type of level gauge [ITA-8.1]


2. C to C distance in mm [or inches]
3. Design [Indication rail]
4. C to C distance > 5000 mm
5. Reinforcement
6. Process connection [side/side]
7. Drain plug
8. Float pipe top end finish
8.1 Bolts & nuts top end finish
9. Mounting link for add. Fixing on the tank
10. Float

ITA-8.1

119
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.14.1 ITA-8.2 [PP]

Characteristics: PN6 / Material: PP

Key:
1 Float pipe PP, dimensions 63 x 47 mm
2 c to c distance
3 Design (indication rail)
6 Process connection side/side
7 Drain plug
8 Float pipe top end finish
9 Mounting link
10 Float

120
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-8.2

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 63 x 4,7 mm
Process connection: to specify:
Flanges DN15…50 (1/2"…2")
Drain/Vent connections: Plug R1/2" (for more please see order codes)
Pipe material: PP
Flange material: same as pipe material
Float material: PP
Operation temperature: -30..+80 °C
Operation pressure: max. 6 bar
Operation density: min. 0,65 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: SS
Gasket Viton
Indication rail: Aluminium
1.4301
Float types: Cylindical, sealed type
Length:
- 255 mm
- 135 mm
Standard dimensions: A = 240 mm*
B = 130 mm
C = 110 mm

Base equipment printed in bold letters!


*for densities < 0,65 kg/dm³ enlarge scale A

121
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.14.2 Order codes ITA-8.2 (PP)

Mag. Level Gauge


ITA-8.2 PN6 (PP)
Float pipe and flange material PP

Order codes for mag. level gauge type ITA-8.2 PN6 (PP)

Code Description
ITA-8.1 1. Float pipe PP
Dimensions 63 x 4,7 mm
2. C to C distance
L C to C distance in mm
3. Design
0 without indication rail, each 100 mm
1 Indication rail material Aluminium, max. 80 °C liquid temperature, each 100 mm
2 Indication rail material 1.4401, max. 80 °C liquid temperature, each 100 mm
4. C to C distance < 5000 mm
A < 5000 without flange connection DN 32 PN 6
B > 5000 with flange connection DN32 PN 6
5. Reinforcement
0 without reinforcement
Reinforcement of the PP-guide tube, material: 1.4404, base price
A
+ length dependent price each 100 mm guide tube
6. Process connections side/side
Y Welding connection (please specify)
Z Threaded connection (please specify)
1 Flanges DN 15 PN 6
2 Flanges DN 15 PN 10
3 Flanges DN 20 PN 6
4 Flanges DN 20 PN 10
5 Flanges DN 25 PN 6
6 Flanges DN 25 PN 10
7 Flanges DN 32 PN 6
8 Flanges DN 32 PN 10
9 Flanges DN 40 PN 6
A Flanges DN 40 PN 10
B Flanges DN 50 PN 6
C Flanges DN 50 PN 10
D Flanges 1/2" ANSI 150 lbs
E Flanges 3/4" ANSI 150 lbs
F Flanges 1" ANSI 150 lbs
G Flanges 1 1/4" ANSI 150 lbs
H Flanges 1 1/2" ANSI 150 lbs
K Flanges 2" ANSI 150 lbs
7. Drain plug
0 without
1 Drain plug R1/2"
2 Drain plug 1/2" NPT
3 Drain plug 3/4" NPT

122
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-8.2 PN6 (PP)
Float pipe and flanges material: PP

Order codes for mag. Level Gauges type: ITA-8.2 PN6 (PP)

Description
8. Float pipe top end finish
A End cap
B Vent plug R1/2"
C Vent plug 1/2" NPT
D Vent plug 3/4" NPT
E Flange DN32 PN6
8.1 Nuts & bolts top end finish flange
0 without
1 M8 x 60 mm; mat. SS 1.4301; DIN 931
9. Mounting link for additional fixing on the tank
0 without
1 Mounting link for additional fixing on the tank
9. Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
8PP001K1 10 PP 50 135 0,9500 N only with 316SS or Aluminium indication rail
8PP002K1 10 PP 50 255 0,6500 N only with 316SS or Aluminium indication rail

For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

123
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.14.2 Order scheme for ITA-8.2

1. Type of level gauge [ITA-8.2]


2. C to C distance in mm [or inches]
3. Design [Indication rail]
4. C to C distance > 5000 mm
5. Reinforcement
6. Process connection [side/side]
7. Drain plug
8. Float pipe top end finish
8.1 Bolts & nuts top end finish
9. Mounting link for add. Fixing on the tank
10. Float

ITA-8.2

124
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.15.1 ITA-8.3 [PVDF]

Characteristics: PN6 / Material: PVDF

Key:
1 Float pipe PVDF, dimensions 63 x 47 mm
2 c to c distance
3 Design (indication rail)
6 Process connection side/side
7 Drain plug
8 Float pipe top end finish
9 Mounting link
10 Float

125
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-8.3

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 63 x 4,7 mm
Process connection: to specify:
Flanges DN15…50 (1/2"…2")
Drain/Vent connections: Plug R1/2" (for more please see order codes)
Pipe material: PVDF
Flange material: same as pipe material
Float material: PVDF
Operation temperature: -40..+120 °C
Operation pressure: max. 6 bar
Operation density: min. 0,85 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: SS
Gasket Viton
Indication rail: Aluminium
1.4301
Float types: Cylindical, sealed type
Length:
- 255 mm
- 135 mm
Standard dimensions: A = 240 mm*
B = 130 mm
C = 110 mm

Base equipment printed in bold letters!


*for densities < 0,85 kg/dm³ enlarge scale A

126
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.15.2 Order codes ITA-8.3 (PVDF)

Mag. Level Gauge


ITA-8.3 PN6 (PVDF)
Float pipe and flange material PVDF

Order codes for mag. level gauge type ITA-8.3 PN6 (PVDF)

Code Description
ITA-8.3 1. Float pipe PVDF
Dimensions 63 x 2 mm
2. C to C distance
L C to C distance in mm
3. Design
0 without indication rail, each 100 mm
1 Indication rail material Aluminium, max. 120 °C liquid temperature, each 100 mm
2 Indication rail material 1.4401, max. 120 °C liquid temperature, each 100 mm
4. C to C distance < 5000 mm
A < 5000 without flange connection DN 32 PN 6
B > 5000 with flange connection DN32 PN 6
5. Reinforcement
0 without reinforcement
Reinforcement of the PVDF-guide tube, material: 1.4404, base price
A
+ length dependent price each 100 mm guide tube
6. Process connections side/side
Y Welding connection (please specify)
Z Threaded connection (please specify)
1 Flanges DN 15 PN 6
2 Flanges DN 15 PN 10
3 Flanges DN 20 PN 6
4 Flanges DN 20 PN 10
5 Flanges DN 25 PN 6
6 Flanges DN 25 PN 10
7 Flanges DN 32 PN 6
8 Flanges DN 32 PN 10
9 Flanges DN 40 PN 6
A Flanges DN 40 PN 10
B Flanges DN 50 PN 6
C Flanges DN 50 PN 10
D Flanges 1/2" ANSI 150 lbs
E Flanges 3/4" ANSI 150 lbs
F Flanges 1" ANSI 150 lbs
G Flanges 1 1/4" ANSI 150 lbs
H Flanges 1 1/2" ANSI 150 lbs
K Flanges 2" ANSI 150 lbs
7. Drain plug
0 without
1 Drain plug R1/2"
2 Drain plug 1/2" NPT
3 Drain plug 3/4" NPT

127
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-8.3 PN6 (PVDF)
Float pipe and flanges material: PVDF

Order codes for mag. Level Gauges type: ITA-8.3 PN6 (PVDF)

Description
8. Float pipe top end finish
A End cap
B Vent plug R1/2"
C Vent plug 1/2" NPT
D Vent plug 3/4" NPT
E Flange DN32 PN6
8.1 Nuts & bolts top end finish flange
0 without
1 M8 x 60 mm; mat. SS 1.4301; DIN 931
9. Mounting link for additional fixing on the tank
0 without
1 Mounting link for additional fixing on the tank
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
8PVDF1K1 10 PVDF 50 135 1,3000 N only with 316SS or Aluminium indication rail
8PVDF2K1 10 PVDF 50 255 0,8500 N only with 316SS or Aluminium indication rail

For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

128
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.15.2 Order scheme for ITA-8.3

1. Type of level gauge [ITA-8.3]


2. C to C distance in mm [or inches]
3. Design [Indication rail]
4. C to C distance > 5000 mm
5. Reinforcement
6. Process connection [side/side]
7. Drain plug
8. Float pipe top end finish
8.1 Bolts & nuts top end finish
9. Mounting link for add. Fixing on the tank
10. Float

ITA-8.3

129
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.16.1 ITA-9.1 [PVC]

Characteristics: PN6 / Material: PVC


(mounted from top of tank)

Key:
1 Float pipe PVC, dimensions 63 x 4,7 mm
2 Measuring length
3 Design (indication rail)
4 Process connection on tank
5 Follower magnet guide tube topside finish

130
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-9.1

Principle: Communicating tubes with magnetic float


Mounting position: top of tank
Measuring range: max. 2500 mm
Pipe diameter: 63 x 4,7 mm
Process connection: Flanged DN 80 (3")
Flanged DN100…DN150 (4"…6")
Drain/Vent connections: Flanged DN32 PN6
Pipe material: PVC
Flange material: same as pipe material
Float material: PVC
Operation temperature: -30..+50 °C
Operation pressure: max. 6 bar
Operation density: min. 0,7 kg/dm³
(depending on the measuring length)
Viscosity: max. 5000 mPa s
Bolts & Nuts: SS
Gasket Viton
Indication rail: Aluminium
1.4301
Float types: Cylindical, sealed type, with rod
Length:
- 250 mm
- (special sizes available)

Base equipment printed in bold letters!

131
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.16.2 Order codes ITA-9.1 (PVC)

Mag. Level Gauge


ITA-9.1 PN 6 PVC
PN6 / PVC / mounted on top of tank

Order codes for mag. level gauge type ITA-9.1 PN 6 (PVC, bis 60 °C)

Code Description
ITA-9.1 1. Float pipe
Dimensions 63 x 4,7 mm
2. Measuring length
L Measuring length in mm (max. 2500 mm, depending on the liquid's density)
3. Design
0 without indication rail, each 100 mm
1 Indication rail material Aluminium, max. 60 °C liquid temperature, each 100 mm
2 Indication rail material 1.4401, max. 60 °C liquid temperature, each 100 mm
4. Process connection onto Tank (FF)
1 Flange DN 80/PN 6
2 Flange DN 100/PN 6
3 Flange DN 150/PN 6
A Flange 3" ANSI/150 lbs
B Flange 4" ANSI/150 lbs
C Flange 6" ANSI/150 lbs
5. Follower magnet guide tube topside finish
1 Vent plug R1/2"
2 Vent plug 1/2"NPT
3 Vent plug 3/4" NPT
4 Flange with blind flange DN32 PN 6
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
9PVC03K1 6 PVC 50 135 N only with 316SS or Aluminium indication rail

NOTE: The prices for the single parts in the above price list are only meant for the composition of a complete level gauge.
For spare parts prices, please refer to the chapter "Spare parts".
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

132
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.16.2 Order scheme for ITA-9.1

1. Type of level gauge [ITA-9.1]


2. Measuring length in mm [or inches]
3. Design [Indication rail]
4. Process connection on the tank [FF]
5. Follower magnet guide tube topside finish
6. Float

ITA-9.1

133
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.17.1 ITA-9.2 [PP]

Characteristics: PN6 / Material: PP


(mounted from top of tank)

Key:
1 Float pipe PP, dimensions 63 x 3,6 mm
2 Measuring length
3 Design (indication rail)
4 Process connection on tank
5 Follower magnet guide tube topside finish

134
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-9.2

Principle: Communicating tubes with magnetic float


Mounting position: top of tank
Measuring range: max. 2500 mm
Pipe diameter: 63 x 3,6 mm
Process connection: Flanged DN 80 (3")
Flanged DN100…DN150 (4"…6")
Drain/Vent connections: Flanged DN32 PN6
Pipe material: PP
Flange material: same as pipe material
Float material: PP
Operation temperature: -10..+80 °C
Operation pressure: max. 6 bar
Operation density: min. 0,7 kg/dm³
(depending on the measuring length)
Viscosity: max. 5000 mPa s
Bolts & Nuts: SS
Gasket Viton
Indication rail: Aluminium
1.4301
Float types: Cylindical, sealed type, with rod
Length:
- 250 mm
- (special sizes available)

Base equipment printed in bold letters!

135
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.17.2 Order codes ITA-9.2 (PP)

Mag. Level Gauge


ITA-9.2 PN 6 PP
PN6 / PP / mounted on top of tank

Order codes for mag. level gauges type ITA-9.2 PN 6 (PP, up to 80 °C)

Code Description
ITA-9.2 1. Float pipe
Dimensions 63 x 3,6 mm
2. Measuring length
L Measuring length in mm (max. 2500 mm, depending on the liquid's density)
3. Design
0 without indication rail, each 100 mm
1 Indication rail material Aluminium, max. 80 °C liquid temperature, each 100 mm
2 Indication rail material 1.4401, max. 80 °C liquid temperature, each 100 mm
4. Process connection onto Tank (FF)
1 Flange DN 80/PN 6
2 Flange DN 100/PN 6
3 Flange DN 150/PN 6
A Flange 3" ANSI/150 lbs
B Flange 4" ANSI/150 lbs
C Flange 6" ANSI/150 lbs
5. Follower magnet guide tube topside finish
1 Vent plug R1/2"
2 Vent plug 1/2"NPT
3 Vent plug 3/4" NPT
4 Flange with blind flange DN32 PN 6
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
9PP030K1 6 PP 50 N only with 316SS or Aluminium indication rail

NOTE: The prices for the single parts in the above price list are only meant for the composition of a complete level gauge.
For spare parts prices, please refer to the chapter "Spare parts".
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

136
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.17.2 Order scheme for ITA-9.2

1. Type of level gauge [ITA-9.2]


2. Measuring length in mm [or inches]
3. Design [Indication rail]
4. Process connection on the tank [FF]
5. Follower magnet guide tube topside finish
6. Float

ITA-9.2

137
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.18.1 ITA-9.3 [PVDF]

Characteristics: PN6 / Material: PVDF


(mounted from top of tank)

Key:
1 Float pipe PVDF, dimensions 63 x 3 mm
2 Measuring length
3 Design (indication rail)
4 Process connection on tank
5 Follower magnet guide tube topside finish

138
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-9.3

Principle: Communicating tubes with magnetic float


Mounting position: top of tank
Measuring range: max. 2500 mm
Pipe diameter: 63 x 3 mm
Process connection: Flanged DN 80 (3")
Flanged DN100…DN150 (4"…6")
Drain/Vent connections: Flanged DN32 PN6
Pipe material: PVDF
Flange material: same as pipe material
Float material: PVDF
Operation temperature: -40..+120 °C
Operation pressure: max. 6 bar
Operation density: min. 0,7 kg/dm³
(depending on the measuring length)
Viscosity: max. 5000 mPa s
Bolts & Nuts: SS
Gasket Viton
Indication rail: Aluminium
1.4301
Float types: Cylindical, sealed type, with rod
Length:
- 250 mm
- (special sizes available)

Base equipment printed in bold letters!

139
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.18.2 Order codes ITA-9.3 (PVDF)

Mag. Level Gauge


ITA-9.3 PN 6 PVDF
PN6 / PP / mounted on top of tank

Order codes for mag. level gauge type ITA-9.3 PN 6 (PVDF, up to 120 °C)

Code Description
ITA-9.3 1. Float Pipe
Dimensions 63 x 3 mm
2. Measuring length
L Measuring length in mm (max. 2500 mm, depending on the liquid's density)
3. Design
0 without indication rail, each 100 mm
1 Indication rail material Aluminium, max. 120 °C liquid temperature, each 100 mm
2 Indication rail material 1.4401, max. 120 °C liquid temperature, each 100 mm
4. Process connection onto tank (FF)
1 Flange DN 80/PN 6
2 Flange DN 100/PN 6
3 Flange DN 150/PN 6
A Flange 3" ANSI/150 lbs
B Flange 4" ANSI/150 lbs
C Flange 6" ANSI/150 lbs
5. Follower magnet guide tube topside finish
1 Vent plug R1/2"
2 Vent plug 1/2"NPT
3 Vent plug 3/4" NPT
4 Flange with blind flange DN32 PN 6
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
9PVD03K 6 PVDF 50 N only with 316SS or Aluminium indication rail

NOTE: The prices for the single parts in the above price list are only meant for the composition of a complete level gauge.
For spare parts prices, please refer to the chapter "Spare parts".
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

140
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.18.2 Order scheme for ITA-9.3

1. Type of level gauge [ITA-9.3]


2. Measuring length in mm [or inches]
3. Design [Indication rail]
4. Process connection on the tank [FF]
5. Follower magnet guide tube topside finish
6. Float

ITA-9.3

141
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.19.1 ITA-10

Characteristics: PN100 / Float pipe and flange material: 1.4571

Key:
1 Float pipe welded, dimensions 60,3 x 3,2 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug

142
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-10

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 3,2 mm seamless,
butt-weld connection wie T-pieces
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 600#),
Welding or threaded stud
Drain/Vent connections: Plug 1/2"NPT
Pipe material: 1.4571; 1.4435; 1.4539; Hastelloy C4 (2.4610);
Inconel 625 (2.4856); Inconel 825 (2.4858);
Titan (3.7035) (other materials on request)
Flange material: same as pipe material
Float material: Titanium***, Titan/E-CTFE-coated
Operation temperature: -50..+400 °C
Operation pressure: max. 100 bar
Operation density: min. 0,4632 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket Spiral wound, 316Ti
Cam profile, 316Ti
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type
Length:
-270 mm
-330 mm
-430 mm
-530 mm
-630 mm
Standard dimensions: -A = 240 mm*
-B = 130 mm**
- C = 70 mm
Base equipment printed in bold letters!
*for densities < 0,4243 kg/dm³ enlarge the scale A
** for end cap B=170 mm for WN
**not for use for hydrogen or alcohol-compounds

143
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.19.2 ITA-10.0

Characteristics: PN100 / Float pipe: 1.4571 and flanges : CS

Key:
1 Float pipe welded, dimensions 60,3 x 3,2 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug

144
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-10.0


Principle: Communicating tubes with magnetic float
Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 3,2 mm seamless,
butt-weld connection wie T-pieces
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 600#),
Welding or threaded stud
Drain/Vent connections: Plug 1/2"NPT
Pipe material: 1.4571
Flange material: CS
Float material: Titanium***, Titan/E-CTFE-coated
Operation temperature: -50..+400 °C
Operation pressure: max. 100 bar
Operation density: min. 0,4632 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket Spiral wound, 316Ti
Cam profile, 316Ti
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type
Length:
-270 mm
-330 mm
-430 mm
-530 mm
-630 mm
Standard dimensions: -A = 240 mm*
-B = 130 mm**
- C = 70 mm
Base equipment printed in bold letters!
*for densities < 0,4243 kg/dm³ enlarge the scale A
** for end cap B=170 mm for WN
**not for use for hydrogen or alcohol-compounds

145
3.19.3 Pressure-Temperature Table ITA-10 (Float pipe)

146
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.19.3 Order codes ITA-10 & ITA-10.0

Mag. Level Gauge


ITA-10 & ITA-10.0 PN100/600 lbs

Order codes for mag. level gauge type ITA-10 & ITA-10.0 PN100/600 lbs

Code Description

ITA-10 1. Float pipe seamless


Dimensions 60,3 x 3,2 mm
2. C to C distance
L C to C distance in mm
3. Design
0 without indication rail each 100 mm
1 Indication rail material: Makrolon max. 120 °C; each 100 mm
2 Indication rail material: Aluminium max. 400 °C, pro 100 mm
3 Indication rail material: 1.4401 max. 400 °C, pro 100 mm
4. C to C distance < 5000 mm
A < 5000 mm - without flange connection; DN 50 PN 100
B > 5000 mm - with flange connection; DN 50 PN 100
5. Process connections side/side
Y Welded connection (please specify)
Z Threaded connection (please specify)
1 Flanges DN 15 PN 100
2 Flanges DN 25 PN 100
3 Flanges DN 32 PN 100
4 Flanges DN 40 PN 100
5 Flanges DN 50 PN 100
A Flanges 1/2" ANSI 600 lbs
B Flanges 3/4" ANSI 600 lbs
C Flanges 1" ANSI 600 lbs
D Flanges 1 1/4" ANSI 600 lbs
E Flanges 1 1/2" ANSI 600 lbs
F Flanges 2" ANSI 600 lbs
5.1 Surface side flanges
0 without
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI)
6. Side studs welded with T-pieces for 100 % X-ray testing
0 without
1 T-pieces

147
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-10 & ITA-10.0 PN100/600 lbs

Order codes for mag. level gauge type ITA-10 & ITA-10.0 PN100/600 lbs

Code Description

7. Float removal flange (bottom side)


1 Flange DN 50 PN 100 incl. blind flange
2 Flange 2" ANSI 600 lbs incl. blind flange
3 Flange DN 50 PN 100 prepared for shut off valve on side
4 Flange 2" ANSI 600 lbs prepared for shut off valve on side
7.1 Surface float removal flange (bottom side) (only DN50 or 2")
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI)
7.2 Bolts & Nuts float removal flange
0 without (Float removal flange (bottom side) = end cap)
61 M24 x 120 mm; mat. steel zinced; Flange DN 50 PN 100
62 M24 x 120 mm; mat. SS 1.4301; Flange DN 50 PN 100
63 M24 x 120 mm; mat. PTFE-coated; Flange 2510 DN50 PN 100
FA 5/8" x 108 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 600 lbs, ANSI B16.5
FB 5/8" x 108 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 600 lbs, ANSI B16.5
FC 5/8" x 108 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 600 lbs; ANSI B16.5
FD 5/8" x 108 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 600 lbs, ANSI B16.5
FT 5/8" x 108 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 600 lbs, ANSI B16.5
FV 5/8" x 108 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 600 lbs; ANSI B16.5
8. Drain plug
0 without
1 Drain plug G 1/2" with soft iron gasket
2 Drain plug 1/2" NPT
3 Drain plug 3/4" NPT
4 Drain plug 1" NPT
9. Additional drain flange, open
0 without
1 Drain stud with flange DN 15 PN 100
2 Drain stud with flange DN 25 PN 100
3 Drain stud with flange DN 32 PN 100
4 Drain stud with flange DN 40 PN 100
A Drain stud with flange 1/2" ANSI 600 lbs
B Drain stud with flange 3/4" ANSI 600 lbs
C Drain stud with flange 1" ANSI 600 lbs
D Drain stud with flange 1 1/4" ANSI 600 lbs
E Drain stud with flange 1 1/2" ANSI 600 lbs

148
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-10 & ITA-10.0 PN100/600 lbs

Order codes for mag. level gauge type ITA-10 & ITA-10.0 PN100/600 lbs

Code Description

9.1 Drain flange with concentric reducer (X-ray testing)


0 without
1 DN 15 PN 100
2 DN 25 PN 100
3 DN 32 PN 100
4 DN 40 PN 100
A 1/2" ANSI 600 lbs
B 3/4" ANSI 600 lbs
C 1" ANSI 600 lbs
D 1 1/4" ANSI 600 lbs
E 1 1/2" ANSI 600 lbs
9.2 Surface open drain flange
0 without
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI)
10. Float pipe top end finish
0 End Cap
1 Flange with blind flange DN 50 PN 100
A Flange with blind flange 2" ANSI 600 lbs
10.1 Surface float pipe top end finish flange (only DN50 or 2")
0 without
B Surface Form E Rz=16
D Surface groove (DIN2512)
E Surface tongue (DIN2512)
F Dichtleiste RF - RA = 3,2 bis 6,3
G Surface RFSF (ANSI)
H Surface groove large ANSI
K Surface tongue-large ANSI
L Surface RTJ (ANSI)
10.2 Bolts & nuts float pipe top end finish flange
0 without
61 M24 x 120 mm; mat. steel zinced; Flange DN 50 PN 100
62 M24 x 120 mm; mat. SS 1.4301; Flange DN 50 PN 100
63 M24 x 120 mm; mat. PTFE-coated; Flange 2510 DN50 PN 100
FA 5/8" x 108 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 600 lbs, ANSI B16.5
FB 5/8" x 108 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 600 lbs, ANSI B16.5

149
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-10 & ITA-10.0 PN100/600 lbs

Order codes for mag. level gauge type ITA-10 & ITA-10.0 PN100/600 lbs

Code Description

10.2 Bolts & nuts float pipe top end finish flange (Continuation)
FC 5/8" x 108 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 600 lbs; ANSI B16.5
FD 5/8" x 108 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 600 lbs, ANSI B16.5
FT 5/8" x 108 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 600 lbs, ANSI B16.5
FV 5/8" x 108 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 600 lbs; ANSI B16.5
11. Vent plug at top end
0 without
1 Vent plug G 1/2" with soft iron gasket
2 Vent plug 1/2" NPT
3 Vent plug 3/4" NPT
4 Vent plug 1" NPT
11.1 Vent flange welded to end cap instead of vent plug
0 without
1 Flange DN 15 PN 100 (socket weld construction to endcap)
2 Flange DN 25 PN 100 (socket weld construction to endcap)
3 Flange DN 32 PN 100 (socket weld construction to endcap)
4 Flange DN 40 PN 100 (socket weld construction to endcap)
A Flange 1/2" ANSI 600 lbs (socket weld construction to endcap)
B Flange 3/4" ANSI 600 lbs (socket weld construction to endcap)
C Flange 1" ANSI 600 lbs (socket weld construction to endcap)
D Flange 1 1/4" ANSI 600 lbs (socket weld construction to endcap)
E Flange 1 1/2" ANSI 600 lbs (socket weld construction to endcap)
11.2 Vent flange with concentric reducer (X-ray testing)
0 without
1 DN 15 PN 100
2 DN 25 PN 100
3 DN 32 PN 100
4 DN 40 PN 100
A 1/2" ANSI 600 lbs
B 3/4" ANSI 600 lbs
C 1" ANSI 600 lbs
D 1 1/4" ANSI 600 lbs
E 1 1/2" ANSI 600 lbs
11.3 Surface vent flange welded to end cap (only DN50 or 2")
0 without
B Surface Form E Rz=16
D Surface groove (DIN2512)
E Surface tongue (DIN2512)
F Standard-Surface RF
G Surface RFSF (smooth finished)
H Surface groove large
K Surface tongue-large
L Surface RTJ (ANSI)

150
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-10 & ITA-10.0 PN100/600 lbs

Order codes for mag. level gauge type ITA-10 & ITA-10.0 PN100/600 lbs

Code Description

12. Counter flanges


0 without
1 DN 15 PN 100
2 DN 25 PN 100
3 DN 32 PN 100
4 DN 40 PN 100
5 DN 50 PN 100
A 1/2" 600 lbs
B 3/4" 600 lbs
C 1" 600 lbs
D 1 1/4" 600 lbs
E 1 1/2" 600 lbs
F 2" 600 lbs
12.1 Surface counter flanges
0 without
B Surface Form E Rz=16
D Surface groove (DIN2512)
E Surface tongue (DIN2512)
F Standard-Surface RF
G Surface RFSF (smooth finished)
H Surface groove large
K Surface tongue-large
L Surface RTJ (ANSI)
12.2 Bolts & Nuts counter flanges
0 without
61 M24 x 120 mm; mat. steel zinced; Flange DN 50 PN 100
62 M24 x 120 mm; mat. SS 1.4301; Flange DN 50 PN 100
63 M24 x 120 mm; mat. PTFE-coated; Flange 2510 DN50 PN 100
FA 5/8" x 108 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 600 lbs, ANSI B16.5
FB 5/8" x 108 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 600 lbs, ANSI B16.5
FC 5/8" x 108 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 600 lbs; ANSI B16.5
FD 5/8" x 108 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 600 lbs, ANSI B16.5
FT 5/8" x 108 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 600 lbs, ANSI B16.5
FV 5/8" x 108 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 600 lbs; ANSI B16.5
13. Additional bracket welded to the float pipe
0 without
H Bracket

151
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-10 & ITA-10.0 PN100/600 lbs

Order codes for mag. Level Gauges type: ITA-10 & ITA-10.0 PN100/600 lbs

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
10V324K3 100 316L 52 265 0,6122 Y only with 316SS or Aluminium indication rail
10T024K1 80 Titanium 50,8 265 0,7011 N do not use for hydrogen or alcohol compounds
10T024K3 80 Titanium 50,8 265 0,5823 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T030K1 80 Titanium 50,8 325 0,6212 N do not use for hydrogen or alcohol compounds
10T030K3 80 Titanium 50,8 325 0,5275 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T040K1 80 Titanium 50,8 425 0,5515 N do not use for hydrogen or alcohol compounds
10T040K3 80 Titanium 50,8 425 0,4871 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T050K1 80 Titanium 50,8 525 0,5095 N do not use for hydrogen or alcohol compounds
10T050K3 80 Titanium 50,8 525 0,4574 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T060K1 80 Titanium 50,8 625 0,4632 N do not use for hydrogen or alcohol compounds
10T060K3 80 Titanium 50,8 625 0,4209 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T124K1 100 Titanium 50,8 265 0,8299 N do not use for hydrogen or alcohol compounds
10T124K3 100 Titanium 50,8 265 0,7006 N only with 316SS or Aluminium indication rail;
Float for high-temperature applications;
do not use for hydrogen or alcohol compounds
10T130K1 100 Titanium 50,8 325 0,7617 N do not use for hydrogen or alcohol compounds
10T130K3 100 Titanium 50,8 325 0,6594 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T140K1 100 Titanium 50,8 425 0,6779 N do not use for hydrogen or alcohol compounds
10T140K3 100 Titanium 50,8 425 0,6075 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T150K1 100 Titanium 50,8 525 0,6321 N do not use for hydrogen or alcohol compounds
10T150K3 100 Titanium 50,8 525 0,5775 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T160K1 100 Titanium 50,8 625 N do not use for hydrogen or alcohol compounds
10T160K3 100 Titanium 50,8 625 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds

For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

152
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.19.4 Order code scheme for ITA-10 & ITA-10.0

1. Type of level gauge ITA-10 or ITA-10.0


2. C to C distance in mm [or inches]
3. Design
4. C to C distance > 5000 mm
5. Process connection [side/side]
5.1 Surface side flanges
6. Side studs welded with T-pieces for 100 % X-ray-testing
7. Float removal flange
7.1 Surface float removal flange
7.2 Bolts & nuts float removal flange
8. Drain plug
9. Additional drain flange, open

ITA-10

ITA-10.0

9.1 Drain flange with concentric reducer (X-ray testing)


9.2 Surface open drain flange
10. Float pipe top end finish
10.1 Surface top end finish flange
10.2 Bolts and nuts rop end finish flange
11. Vent plug at top end
11.1 Vent flange welded to end cap instead of vent plug
11.2 Vent flange with concentric reducer (X-ray testing)
11.3 Surface vent flange welded to end cap
12. Counter flanges
12.1 Surface counter flanges
12.2 Bolts & nuts counter flanges
13. Additional bracket welded to the float pipe
14. Float

153
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.20.1 ITA-11

Characteristics: PN160 / Float pipe and flange material: 1.4571

Key:
1 Float pipe welded, dimensions 60,3 x 3,91 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug

154
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-11

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 3,91 mm seamless,
60,3 x 3,6 mm seamless
welding stud or
butt-weld connection wie T-pieces
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 1500#),
Welding or threaded stud
Drain/Vent connections: Plug 1/2"NPT
Pipe material: 1.4571; 1.4435; 1.4539; Hastelloy C4 (2.4610);
Inconel 625 (2.4856); Inconel 825 (2.4858);
Titan (3.7035) (other materials on request)
Flange material: same as pipe material
Float material: 316Ti (1.4571); Titanium***
Operation temperature: -50..+400 °C
Operation pressure: max. 160 bar
Operation density: min. 0,6008 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket Spiral wound, 316Ti
Cam profile, 316Ti
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type
Length:
-270 mm
-330 mm
-430 mm
-530 mm
Standard dimensions: -A = 240 mm*
-B = 130 mm**
- C = 70 mm
Base equipment printed in bold letters!
*for densities < 0,4243 kg/dm³ enlarge the scale A
** for end cap B=170 mm for WN
**not for use for hydrogen or alcohol-compounds

155
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.20.2 ITA-11.0

Characteristics: PN160 / Float pipe: 1.4571 and flanges : CS

Key:
1 Float pipe welded, dimensions 60,3 x 3,91 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug

156
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-11.0

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 3,91 mm seamless,
60,3 x 3,6 mm seamless
welding stud or
butt-weld connection wie T-pieces
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 1500#),
Welding or threaded stud
Drain/Vent connections: Plug 1/2"NPT
Pipe material: 1.4571
Flange material: CS
Float material: 316Ti (1.4571); Titanium***
Operation temperature: -50..+400 °C
Operation pressure: max. 160 bar
Operation density: min. 0,6008 kg/dm³
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket Spiral wound, 316Ti
Cam profile, 316Ti
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type
Length:
-270 mm
-330 mm
-430 mm
-530 mm
Standard dimensions: -A = 240 mm*
-B = 130 mm**
- C = 70 mm
Base equipment printed in bold letters!
*for densities < 0,4243 kg/dm³ enlarge the scale A
** for end cap B=170 mm for WN
**not for use for hydrogen or alcohol-compounds

157
3.20.3 Pressure-Temperature Table ITA-11 (Float pipe)

158
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.20.4 Order codes ITA-11 & ITA-11.0

Mag. Level Gauge


ITA-11 & ITA-11.0 PN160/1500 lbs

Order codes for mag. level gauge type ITA-11 & ITA-11.0 PN160/1500 lbs

Code Description

ITA-11 1. Float pipe seamless


Dimensions 60,3 x 3,91 mm
2. C to C distance
L C to C distance in mm
3. Design
0 without indication rail each 100 mm
1 Indication rail material: Makrolon max. 120 °C; each 100 mm
2 Indication rail material: Aluminium max. 400 °C, pro 100 mm
3 Indication rail material: 1.4401 max. 400 °C, pro 100 mm
4. C to C distance < 5000 mm
A < 5000 mm - without flange connection; DN 50 PN 160
B > 5000 mm - with flange connection; DN 50 PN 160
5. Process connections side/side
Y welding connection (please specify)
Z threaded connection (please specify)
1 Flanges DN 15 PN 160
2 Flanges DN 25 PN 160
3 Flanges DN 32 PN 160
4 Flanges DN 50 PN 160
A Flanges 1/2" ANSI 1500 lbs
B Flanges 3/4" ANSI 1500 lbs
C Flanges 1" ANSI 1500 lbs
D Flanges 1 1/4" ANSI 1500 lbs
E Flanges 1 1/2" ANSI 1500 lbs
F Flanges 2" ANSI 1500 lbs
5.1 Surface side flanges
0 without
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI)
6. Side studs welded with T-pieces for 100 % X-ray testing
0 without
T T-pieces

159
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-11 & ITA-11.0 PN160/1500 lbs

Order codes for mag. level gauge type ITA-11 & ITA-11.0 PN160/1500 lbs

Code Description

7. Float removal flange (bottom side)


1 Flange DN 50 PN 160 incl. blind flange
A Flange 2" ANSI 1500 lbs incl. blind flange
2 Flange DN 50 PN 160 prepared for shut off valve on side
B Flange 2" ANSI 1500 lbs prepared for shut off valve on side
7.1 Surface float removal flange (bottom side) (only DN50 or 2")
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI)
7.2 Bolts & Nuts float removal flange
0 without (Float removal flange (bottom side) = end cap)
61 M24 x 120 mm; mat. steel zinced; Flange DN 50 PN 160
62 M24 x 120 mm; mat. SS 1.4301; Flange DN 50 PN 160
FA 7/8" x 150 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 1500 lbs, ANSI B16.5
FB 7/8" x 150 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FC 7/8" x 150 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 1500 lbs; ANSI B16.5
FD 7/8" x 150 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FT 7/8" x 150 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 1500 lbs, ANSI B16.5
FV 7/8" x 150 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 1500 lbs; ANSI B16.5
8. Drain plug
0 without
1 Drain plug G 1/2" with soft iron gasket
2 Drain plug 1/2" NPT
3 Drain plug 3/4" NPT
4 Drain plug 1" NPT
9. Additional drain flange, open
0 without
1 Drain stud with flange DN 15 PN 160
2 Drain stud with flange DN 25 PN 160
3 Drain stud with flange DN 32 PN 160
4 Drain stud with flange DN 40 PN 160
A Drain stud with flange 1/2" ANSI 1500 lbs
B Drain stud with flange 3/4" ANSI 1500 lbs
C Drain stud with flange 1" ANSI 1500 lbs
D Drain stud with flange 1 1/4" ANSI 1500 lbs
E Drain stud with flange 1 1/2" ANSI 1500 lbs

160
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-11 & ITA-11.0 PN160/1500 lbs

Order codes for mag. level gauge type ITA-11 & ITA-11.0 PN160/1500 lbs

Code Description

9.1 Drain flange with concentric reducer (X-ray testing)


0 without
1 DN 15 PN 160
2 DN 25 PN 160
3 DN 32 PN 160
4 DN 40 PN 160
A 1/2" ANSI 1500 lbs
B 3/4" ANSI 1500 lbs
C 1" ANSI 1500 lbs
D 1 1/4" ANSI 1500 lbs
E 1 1/2" ANSI 1500 lbs
9.2 Surface open drain flange
0 without
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI)
10. Float pipe top end finish
1 End cap
2 Flange with blind flange DN 50 PN 160
A Flange with blind flange 2" ANSI 1500 lbs
10.1 Surface float pipe top end finish flange (only DN50 or 2")
0 without
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI)
10.2 Bolts & nuts float pipe top end finish flange
0 without
61 M24 x 120 mm; mat. steel zinced; Flange DN 50 PN 160
62 M24 x 120 mm; mat. SS 1.4301; Flange DN 50 PN 160
FA 7/8" x 150 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 1500 lbs, ANSI B16.5
FB 7/8" x 150 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5

161
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-11 & ITA-11.0 PN160/1500 lbs

Order codes for mag. level gauge type ITA-11 & ITA-11.0 PN160/1500 lbs

Code Description

10.2 Bolts & nuts float pipe top end finish flange (Continuation)
FC 7/8" x 150 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 1500 lbs; ANSI B16.5
FD 7/8" x 150 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FT 7/8" x 150 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 1500 lbs, ANSI B16.5
FV 7/8" x 150 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 1500 lbs; ANSI B16.5
11. Vent plug at top end
0 without
1 Vent plug G 1/2" with soft iron gasket
2 Vent plug 1/2" NPT
3 Vent plug 3/4" NPT
4 Vent plug 1" NPT
11.1 Vent flange welded to end cap instead of vent plug
0 without
1 Flange DN 15 PN 160 (socket weld construction to endcap)
2 Flange DN 25 PN 160 (socket weld construction to endcap)
3 Flange DN 32 PN 160 (socket weld construction to endcap)
4 Flange DN 40 PN 160 (socket weld construction to endcap)
A Flange 1/2" ANSI 1500 lbs (socket weld construction to endcap)
B Flange 3/4" ANSI 1500 lbs (socket weld construction to endcap)
C Flange 1" ANSI 1500 lbs (socket weld construction to endcap)
D Flange 1 1/4" ANSI 1500 lbs (socket weld construction to endcap)
E Flange 1 1/2" ANSI 1500 lbs (socket weld construction to endcap)
11.2 Vent flange with concentric reducer (X-ray testing)
0 without
1 DN 15 PN 160
2 DN 25 PN 160
3 DN 32 PN 160
4 DN 40 PN 160
A 1/2" ANSI 1500 lbs
B 3/4" ANSI 1500 lbs
C 1" ANSI 1500 lbs
D 1 1/4" ANSI 1500 lbs
E 1 1/2" ANSI 1500 lbs
11.3 Surface vent flange welded to end cap (only DN50 or 2")
0 without
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI)

162
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-11 & ITA-11.0 PN160/1500 lbs

Order codes for mag. level gauge type ITA-11 & ITA-11.0 PN160/1500 lbs

Code Description

12. Counter flanges


0 without
1 DN 15 PN 160
2 DN 25 PN 160
3 DN 32 PN 160
4 DN 40 PN 160
5 DN 50 PN 100
A 1/2" ANSI 1500 lbs
B 3/4" ANSI 1500 lbs
C 1" ANSI 1500 lbs
D 1 1/4" ANSI 1500 lbs
E 1 1/2" ANSI 1500 lbs
F 2" 600 lbs
12.1 Surface counter flanges
0 without
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
F Surface groove (DIN2512)
G Surface groove large
H Surface tongue (DIN2512)
K Surface tongue-large
L Surface RTJ (ANSI)
12.2 Bolts & Nuts counter flanges
0 without
61 M24 x 120 mm; mat. steel zinced; Flange DN 50 PN 160
62 M24 x 120 mm; mat. SS 1.4301; Flange DN 50 PN 160
FA 7/8" x 150 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 1500 lbs, ANSI B16.5
FB 7/8" x 150 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FC 7/8" x 150 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 1500 lbs; ANSI B16.5
FD 7/8" x 150 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FT 7/8" x 150 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 1500 lbs, ANSI B16.5
FV 7/8" x 150 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 1500 lbs; ANSI B16.5
13. Additional bracket welded to the float pipe
0 without
H Bracket

163
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-11 & ITA-11.0 PN160/1500 lbs

Order codes for mag. Level Gauges type: ITA-11 & ITA-11.0 PN160/1500 lbs

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
11V324K2 160 316L 46 265 0,7736 Y
11T330K2 160 Titanium 46 325 0,4901 Y do not use for hydrogen or alcohol compounds
11T024K1 130 Titanium 45 265 0,86 N do not use for hydrogen or alcohol compounds
11T024K3 130 Titanium 45 265 0,745 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T030K1 130 Titanium 45 325 0,7822 N do not use for hydrogen or alcohol compounds
11T030K3 130 Titanium 45 325 0,6949 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T040K1 130 Titanium 45 425 0,7028 N do not use for hydrogen or alcohol compounds
11T040K3 130 Titanium 45 425 0,6391 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T050K1 130 Titanium 45 525 0,6587 N do not use for hydrogen or alcohol compounds
11T060K1 130 Titanium 45 625 N do not use for hydrogen or alcohol compounds
11T050K3 150 Titanium 45 525 0,6106 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T060K3 150 Titanium 45 625 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T124K3 150 Titanium 46 265 0,7324 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T130K3 150 Titanium 46 325 0,7042 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T140K3 150 Titanium 46 425 0,6164 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T150K3 150 Titanium 46 525 0,6008 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T224K1 160 Titanium 42 265 0,9768 N do not use for hydrogen or alcohol compounds
11T224K3 160 Titanium 42 265 0,812 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T230K1 160 Titanium 42 325 0,8871 N do not use for hydrogen or alcohol compounds
11T230K3 160 Titanium 42 325 0,7613 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T240K1 160 Titanium 42 425 0,7832 N do not use for hydrogen or alcohol compounds
11T240K3 160 Titanium 42 425 0,6934 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T250K1 160 Titanium 42 525 0,7268 N do not use for hydrogen or alcohol compounds
11T250K3 160 Titanium 42 525 0,6571 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T260K1 160 Titanium 42 625 N do not use for hydrogen or alcohol compounds
11T260K3 160 Titanium 42 625 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds

For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

164
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.20.4 Order code scheme for ITA-11 & ITA-11.0

1. Type of level gauge ITA-11 or ITA-11.0


2. C to C distance in mm [or inches]
3. Design
4. C to C distance > 5000 mm
5. Process connection [side/side]
5.1 Surface side flanges
6. Side studs welded with T-pieces for 100 % X-ray-testing
7. Float removal flange
7.1 Surface float removal flange
7.2 Bolts & nuts float removal flange
8. Drain plug
9. Additional drain flange, open

ITA-11

ITA-11.0

9.1 Drain flange with concentric reducer (X-ray testing)


9.2 Surface open drain flange
10. Float pipe top end finish
10.1 Surface top end finish flange
10.2 Bolts and nuts rop end finish flange
11. Vent plug at top end
11.1 Vent flange welded to end cap instead of vent plug
11.2 Vent flange with concentric reducer (X-ray testing)
11.3 Surface vent flange welded to end cap
12. Counter flanges
12.1 Surface counter flanges
12.2 Bolts & nuts counter flanges
13. Additional bracket welded to the float pipe
14. Float

165
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.21.1 ITA-12

Characteristics: PN250 / Float pipe and flange material: 1.4571

Key:
1 Float pipe welded, dimensions 60,3 x 5,54 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug

166
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-12

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 5,54 mm seamless,
welding stud or
butt-weld connection wie T-pieces
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 1500#),
Welding or threaded stud
Drain/Vent connections: Plug 1/2"NPT
Pipe material: 1.4571; 1.4435; 1.4539; Hastelloy C4 (2.4610);
Inconel 625 (2.4856); Inconel 825 (2.4858);
Titan (3.7035) (other materials on request)
Flange material: same as pipe material
Float material: 316Ti (1.4571); Titanium***
Operation temperature: -50..+400 °C
Operation pressure: max. 250 bar
min. 0,57 kg/dm³ (vented float)
Operation density: min. 0,828 kg/dm³ (sealed float)
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket Spiral wound, 316Ti
Cam profile, 316Ti
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type (Titanium)
Length:
-270 mm
-330 mm
Standard dimensions: -A = 240 mm*
-B = 130 mm**
- C = 100 mm
Base equipment printed in bold letters!
*for densities < 0,57 kg/dm³ enlarge the scale A
** for end cap B=170 mm for WN
**not for use for hydrogen or alcohol-compounds

167
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.21.2 ITA-12.0

Characteristics: PN250 / Float pipe: 1.4571 and flanges : CS

Key:
1 Float pipe welded, dimensions 60,3 x 5,54 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug

168
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-12.0

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 5,54 mm seamless,
welding stud or
butt-weld connection wie T-pieces
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 1500#),
Welding or threaded stud
Drain/Vent connections: Plug 1/2"NPT
Pipe material: 1.4571
Flange material: CS
Float material: 316Ti (1.4571); Titanium***
Operation temperature: -50..+400 °C
Operation pressure: max. 250 bar
min. 0,57 kg/dm³ (vented float)
Operation density: min. 0,828 kg/dm³ (sealed float)
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket Spiral wound, 316Ti
Cam profile, 316Ti
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type (Titanium)
Length:
-270 mm
-330 mm
Standard dimensions: -A = 240 mm*
-B = 130 mm**
- C = 100 mm
Base equipment printed in bold letters!
*for densities < 0,57 kg/dm³ enlarge the scale A
** for end cap B=170 mm for WN
**not for use for hydrogen or alcohol-compounds

169
3.21.3 Pressure-Temperature Table ITA-12 (Float pipe)

170
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.21.4 Order codes ITA-12 & ITA-12.0

Mag. Level Gauge


ITA-12 & ITA-12.0 PN250/1500 lbs

Order codes for mag. level gauge type ITA-12 & ITA-12.0 PN250/1500 lbs

Code Description

ITA-12 1. Float pipe seamless


ITA-12.0 Dimensions 60,3 x 5,54 mm
2. C to C distance
L C to C distance in mm
3. Design
0 without indication rail each 100 mm
1 Indication rail material: Makrolon max. 120 °C; each 100 mm
2 Indication rail material: Aluminium max. 400 °C, pro 100 mm
3 Indication rail material: 1.4401 max. 400 °C, pro 100 mm
4. C to C distance < 5000 mm
A < 5000 mm - without flange connection; DN 50 PN 250
B > 5000 mm - with flange connection; DN 50 PN 250
5. Process connections side/side
Y Welding connection (please specify)
Z Threaded stud (please specify)
0 Flanges DN 15 PN 250
1 Flanges DN 25 PN 250
2 Flanges DN 32 PN 250
3 Flanges DN 40 PN 250
4 Flanges DN 50 PN 250
A Flanges 1/2" ANSI 1500 lbs
B Flanges 3/4" ANSI 1500 lbs
C Flanges 1" ANSI 1500 lbs
D Flanges 1 1/4" ANSI 1500 lbs
E Flanges 1 1/2" ANSI 1500 lbs
F Flanges 2" ANSI 1500 lbs
5.1 Surface side flanges
0 without
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
G Surface groove large
K Surface tongue-large
L Surface RTJ (ANSI)
6. Side studs welded with T-pieces for 100 % X-ray testing
0 without
T T-pieces

171
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-12 & ITA-12.0 PN250/1500 lbs

Order codes for mag. level gauge type ITA-12 & ITA-12.0 PN250/1500 lbs

Code Description

7. Float removal flange (bottom side)


1 Flange DN 50 PN 250 incl. blind flange
A Flange 2" ANSI 1500 lbs incl. blind flange
2 Flange DN 50 PN 250 prepared for shut off valve on side
B Flange 2" ANSI 1500 lbs prepared for shut off valve on side
7.1 Surface float removal flange (bottom side)
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
G Surface groove large
K Surface tongue-large
L Surface RTJ (ANSI)
7.2 Bolts & Nuts float removal flange
0 without (Float removal flange (bottom side) = end cap)
61 M24 x 140 mm; mat. steel zinced; Flange DN 50 PN 250
62 M24 x 140 mm; mat. SS 1.4301; Flange DN 50 PN 250
6X M24 x 140 mm; mat. steel zinced A193B7 / A1942H; Flange 2" ANSI 1500 lbs
FA 7/8" x 150 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 1500 lbs, ANSI B16.5
FB 7/8" x 150 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FC 7/8" x 160 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 1500 lbs; ANSI B16.5
FD 7/8" x 150 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FT 7/8" x 160 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 1500 lbs, ANSI B16.5
FV 7/8" x 160 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 1500 lbs; ANSI B16.5
8. Drain plug
0 without
1 Drain plug G 1/2" with soft iron gasket
2 Drain plug 1/2" NPT
3 Drain plug 3/4" NPT
4 Drain plug 1" NPT
9. Additional drain flange, open
0 without
1 Drain-stud with flange DN 15 PN 250
2 Drain-stud with flange DN 25 PN 250
3 Drain-stud with flange DN 32 PN 250
4 Drain-stud with flange DN 40 PN 250
A Drain-stud with flange 1/2" ANSI 1500 lbs
B Drain-stud with flange 3/4" ANSI 1500 lbs
C Drain-stud with flange 1" ANSI 1500 lbs
D Drain-stud with flange 1 1/4" ANSI 1500 lbs
E Drain-stud with flange 1 1/2" ANSI 1500 lbs

172
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-12 & ITA-12.0 PN250/1500 lbs

Order codes for mag. level gauge type ITA-12 & ITA-12.0 PN250/1500 lbs

Code Description

9.1 Drain flange with concentric reducer (X-ray testing)


0 without
1 DN 15 PN 250
2 DN 25 PN 250
3 DN 32 PN 250
4 DN 40 PN 250
A 1/2" ANSI 1500 lbs
B 3/4" ANSI 1500 lbs
C 1" ANSI 1500 lbs
D 1 1/4" ANSI 1500 lbs
E 1 1/2" ANSI 1500 lbs
9.2 Surface open drain flange
0 without
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
G Surface groove large
K Surface tongue-large
L Surface RTJ (ANSI)
10. Float pipe top end finish
1 End cap
2 Flange with blind flange DN 50 PN 250
A Flange with blind flange 2" ANSI 1500 lbs
10.1 Surface float pipe top end finish flange (only DN50 or 2")
0 without
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
G Surface groove large
K Surface tongue-large
L Surface RTJ (ANSI)
10.2 Bolts & nuts float pipe top end finish flange
0 without
61 M24 x 140 mm; mat. steel zinced; Flange DN 50 PN 250
62 M24 x 140 mm; mat. SS 1.4301; Flange DN 50 PN 250
6X M24 x 140 mm; mat. steel zinced A193B7 / A1942H; Flange 2" ANSI 1500 lbs
FA 7/8" x 150 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 1500 lbs, ANSI B16.5
FB 7/8" x 150 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FC 7/8" x 160 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 1500 lbs; ANSI B16.5
FD 7/8" x 150 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FT 7/8" x 160 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 1500 lbs, ANSI B16.5
FV 7/8" x 160 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 1500 lbs; ANSI B16.5

173
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-12 & ITA-12.0 PN250/1500 lbs

Order codes for mag. level gauge type ITA-12 & ITA-12.0 PN250/1500 lbs

Code Description

11. Vent plug at top end


0 without
1 Vent plug G1/2" with soft iron gasket
2 Vent plug 1/2" NPT
3 Vent plug 3/4" NPT
4 Vent plug 1" NPT
11.1 Vent flange welded to end cap instead of vent plug
0 without
1 Flange DN 15 PN 250 (socket weld construction to endcap)
2 Flange DN 25 PN 250 (socket weld construction to endcap)
3 Flange DN 32 PN 250 (socket weld construction to endcap)
4 Flange DN 40 PN 250 (socket weld construction to endcap)
A Flange 1/2" ANSI 1500 lbs (socket weld construction to endcap)
B Flange 3/4" ANSI 1500 lbs (socket weld construction to endcap)
C Flange 1" ANSI 1500 lbs (socket weld construction to endcap)
D Flange 1 1/4" ANSI 1500 lbs (socket weld construction to endcap)
E Flange 1 1/2" ANSI 1500 lbs (socket weld construction to endcap)
11.2 Vent flange with concentric reducer (X-ray testing)
0 without
1 DN 15 PN 250
2 DN 25 PN 250
3 DN 32 PN 250
4 DN 40 PN 250
A 1/2" ANSI 1500 lbs
B 3/4" ANSI 1500 lbs
C 1" ANSI 1500 lbs
D 1 1/4" ANSI 1500 lbs
E 1 1/2" ANSI 1500 lbs
11.3 Surface vent flange welded to end cap (only DN50 or 2")
0 without
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
G Surface groove large
K Surface tongue-large
L Surface RTJ (ANSI)

174
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-12 & ITA-12.0 PN250/1500 lbs

Order codes for mag. level gauge type ITA-12 & ITA-12.0 PN250/1500 lbs

Code Description

12. Counter flanges


0 without
1 DN 15 PN 250
2 DN 25 PN 250
3 DN 32 PN 250
4 DN 40 PN 250
5 DN 50 PN 250
A 1/2" ANSI 1500 lbs
B 3/4" ANSI 1500 lbs
C 1" ANSI 1500 lbs
D 1 1/4" ANSI 1500 lbs
E 1 1/2" ANSI 1500 lbs
F 2" ANSI 1500 lbs
12.1 Surface counter flanges
0 without
B Standard-Surface RF
D Surface Form E Rz=16
E Surface RFSF (smooth finished)
G Surface groove large
K Surface tongue-large
L Surface RTJ (ANSI)
12.2 Bolts & Nuts counter flanges
0 without
61 M24 x 140 mm; mat. steel zinced; Flange DN 50 PN 250
62 M24 x 140 mm; mat. SS 1.4301; Flange DN 50 PN 250
6X M24 x 140 mm; mat. steel zinced A193B7 / A1942H; Flange 2" ANSI 1500 lbs
FA 7/8" x 150 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 1500 lbs, ANSI B16.5
FB 7/8" x 150 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FC 7/8" x 160 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 1500 lbs; ANSI B16.5
FD 7/8" x 150 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FT 7/8" x 160 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 1500 lbs, ANSI B16.5
FV 7/8" x 160 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 1500 lbs; ANSI B16.5
13. Additional bracket welded to the float pipe
0 without
H Bracket

175
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-12 & ITA-12.0 PN250/1500 lbs

Order codes for mag. Level Gauges type: ITA-12 & ITA-12.0 PN250/1500 lbs

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
12V324K1 250 316L 46 265 0,7736 Y
12T324K3 250 Titanium 46 265 0,5526 Y only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T224K1 250 Titanium 42 265 1,0396 N do not use for hydrogen or alcohol compounds
12T224K3 250 Titanium 42 265 0,9659 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T230K1 250 Titanium 42 325 0,9250 N do not use for hydrogen or alcohol compounds
12T230K3 250 Titanium 42 325 0,7978 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T240K1 250 Titanium 42 425 0,8304 N do not use for hydrogen or alcohol compounds
12T240K3 250 Titanium 42 425 0,7394 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T250K1 250 Titanium 42 525 0,7763 N do not use for hydrogen or alcohol compounds
12T250K3 250 Titanium 42 525 0,7055 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T124K3 250 Titanium 38 265 0,8944 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T130K3 250 Titanium 38 325 0,8281 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds

NOTE: The prices for the single parts in the above price list are only meant for the composition of a complete level gauge.
For spare parts prices, please refer to the chapter "Spare parts".
For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

176
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.21.4 Order code scheme for ITA-12 & ITA-12.0

1. Type of level gauge ITA-12 or ITA-12.0


2. C to C distance in mm [or inches]
3. Design
4. C to C distance > 5000 mm
5. Process connection [side/side]
5.1 Surface side flanges
6. Side studs welded with T-pieces for 100 % X-ray-testing
7. Float removal flange
7.1 Surface float removal flange
7.2 Bolts & nuts float removal flange
8. Drain plug
9. Additional drain flange, open

ITA-12

ITA-12.0

9.1 Drain flange with concentric reducer (X-ray testing)


9.2 Surface open drain flange
10. Float pipe top end finish
10.1 Surface top end finish flange
10.2 Bolts and nuts rop end finish flange
11. Vent plug at top end
11.1 Vent flange welded to end cap instead of vent plug
11.2 Vent flange with concentric reducer (X-ray testing)
11.3 Surface vent flange welded to end cap
12. Counter flanges
12.1 Surface counter flanges
12.2 Bolts & nuts counter flanges
13. Additional bracket welded to the float pipe
14. Float

177
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.22.1 ITA-13

Characteristics: PN320 / Float pipe and flange material: 1.4571

Key:
1 Float pipe welded, dimensions 60,3 x 8,7 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug

178
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-13

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 8,7 mm seamless,
welding stud or
butt-weld connection wie T-pieces
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 2500#),
Welding or threaded stud
Drain/Vent connections: Plug 1/2"NPT
Pipe material: 1.4571; 1.4435; 1.4539; Hastelloy C4 (2.4610);
Inconel 625 (2.4856); Inconel 825 (2.4858);
Titan (3.7035) (other materials on request)
Flange material: same as pipe material
Float material: Titanium***
Operation temperature: -50..+400 °C
Operation pressure: max. 320 bar
min. 0,5032 kg/dm³ (vented float)
Operation density: min. 0,7582 kg/dm³ (sealed float)
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket Spiral wound, 316Ti
Cam profile, 316Ti
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type (Titanium)
Length:
-270 mm
-330 mm
-430 mm
Standard dimensions: -A = 240 mm*
-B = 130 mm**
- C = 100 mm
Base equipment printed in bold letters!
*depending on density enlarge the scale A
** for end cap B=170 mm for WN
**not for use for hydrogen or alcohol-compounds

179
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.22.2 ITA-13.0

Characteristics: PN320 / Float pipe: 1.4571 and flanges : CS

Key:
1 Float pipe welded, dimensions 60,3 x 8,7 mm 9 Additional drain flange, open
2 c to c distance 10 Float pipe top end finish
3 Design (indication rail) 11 Vent plug
5 Process connection side/side 12 Counter flanges
6 Side studs welded with T pieces 13 Additional bracket
for 100 % X-ray testing 14 Float pipe seamless
7 Float removal flange 15 Float
8 Drain plug

180
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Technical specifications magnetic level gauge type ITA-13.0

Principle: Communicating tubes with magnetic float


Mounting position: vertical
Measuring range: max. 5000 mm (one-part)
> 5000 mm 2- or multipart
Pipe diameter: 60,3 x 8,7 mm seamless,
welding stud or
butt-weld connection wie T-pieces
Process connection: to specify:
Flanges DN15…50 (1/2"…2" 2500#),
Welding or threaded stud
Drain/Vent connections: Plug 1/2"NPT
Pipe material: 1.4571
Flange material: CS
Float material: Titanium***
Operation temperature: -50..+400 °C
Operation pressure: max. 320 bar
min. 0,5032 kg/dm³ (vented float)
Operation density: min. 0,7582 kg/dm³ (sealed float)
Viscosity: max. 5000 mPa s
Bolts & Nuts: CS
SS
Gasket Spiral wound, 316Ti
Cam profile, 316Ti
Indication rail: Makrolon up to 120 °C
Aluminium up to 400 °C
1.4301 up to 400 °C
Float types: Cylindical, sealed type (Titanium)
Length:
-270 mm
-330 mm
-430 mm
Standard dimensions: -A = 240 mm*
-B = 130 mm**
- C = 100 mm
Base equipment printed in bold letters!
*depending on density enlarge the scale A
** for end cap B=170 mm for WN
**not for use for hydrogen or alcohol-compounds

181
3.22.3 Pressure-Temperature Table ITA-13 (Float pipe)

182
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.22.4 Order codes ITA-13 & ITA-13.0

Mag. Level Gauge


ITA-13 & ITA-13.0 PN320/2500 lbs

Order codes for mag. level gauge type ITA-13 & ITA-13.0 PN320/2500 lbs

Code Description

ITA-13 1. Float pipe seamless


Dimensions 60,3 x 8,7 mm
2. C to C distance
L C to C distance in mm
3. Design
0 without indication rail each 100 mm
1 Indication rail material: Makrolon max. 120 °C; each 100 mm
2 Indication rail material: Aluminium max. 400 °C, pro 100 mm
3 Indication rail material: 1.4401 max. 400 °C, pro 100 mm
4. C to C distance < 5000 mm
A < 5000 mm - without flange connection; DN 50 PN 320
B > 5000 mm - with flange connection; DN 50 PN 320
5. Process connections side/side
Y Welding connections (please specify)
Z Threaded connections (please specify)
0 Flanges DN 15 PN 320
1 Flanges DN 25 PN 320
2 Flanges DN 32 PN 320
3 Flanges DN 40 PN 320
4 Flanges DN 50 PN 320
A Flanges 1/2" ANSI 2500 lbs
B Flanges 3/4" ANSI 2500 lbs
C Flanges 1" ANSI 2500 lbs
D Flanges 1 1/4" ANSI 2500 lbs
E Flanges 1 1/2" ANSI 2500 lbs
F Flanges 2" ANSI 2500 lbs
5.1 Surface side flanges
0 without
C Standard-Surface RF
F Surface Form E Rz=16
G Surface RFSF (smooth finished)
H Surface groove large
I Surface tongue-large
J Surface RTJ (ANSI)
6. Side studs welded with T-pieces for 100 % X-ray testing
0 without
T T-pieces

183
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-13 & ITA-13.0 PN320/2500 lbs

Order codes for mag. level gauge type ITA-13 & ITA-13.0 PN320/2500 lbs

Code Description

7. Float removal flange (bottom side)


1 Flange DN 50 PN 320 incl. blind flange
A Flange 2" ANSI 2500 lbs incl. blind flange
2 Flange DN 50 PN 320 prepared for shut off valve on side
B Flange 2" ANSI 2500 lbs prepared for shut off valve on side
7.1 Surface float removal flange (bottom side)
C Standard-Surface RF
F Surface Form E Rz=16
G Surface RFSF (smooth finished)
H Surface groove large
I Surface tongue-large
J Surface RTJ (ANSI)
7.2 Bolts & Nuts float removal flange
0 without (Float removal flange (bottom side) = end cap)
61 M24 x 150 mm; mat. steel zinced; Flange DN 50 PN 320
62 M24 x 150 mm; mat. SS 1.4301; Flange DN 50 PN 320
6X M24 x 150 mm; PTFE coated; Flange DN 50 PN 320; DIN 2510
FA 7/8" x 150 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 1500 lbs, ANSI B16.5
FB 7/8" x 150 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FC 7/8" x 160 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 1500 lbs; ANSI B16.5
FD 7/8" x 150 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FT 7/8" x 160 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 1500 lbs, ANSI B16.5
FV 7/8" x 160 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 1500 lbs; ANSI B16.5
8. Drain plug
0 without
1 Drain plug G 1/2" with soft iron gasket
2 Drain plug 1/2" NPT
3 Drain plug 3/4" NPT
4 Drain plug 1" NPT
9. Additional drain flange, open
0 without
1 Drain stud with flange DN 15 PN 320
2 Drain stud with flange DN 25 PN 320
3 Drain stud with flange DN 32 PN 320
4 Drain stud with flange DN 40 PN 320
A Drain stud with flange 1/2" ANSI 2500 lbs
B Drain stud with flange 3/4" ANSI 2500 lbs
C Drain stud with flange 1" ANSI 2500 lbs
D Drain stud with flange 1 1/4" ANSI 2500 lbs
E Drain stud with flange 1 1/2" ANSI 2500 lbs

184
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-13 & ITA-13.0 PN320/2500 lbs

Order codes for mag. level gauge type ITA-13 & ITA-13.0 PN320/2500 lbs

Code Description

9.1 Drain flange with concentric reducer (X-ray testing)


0 without
1 DN 15 PN 320
2 DN 25 PN 320
3 DN 32 PN 320
4 DN 40 PN 320
A 1/2" ANSI 2500 lbs
B 3/4" ANSI 2500 lbs
C 1" ANSI 2500 lbs
D 1 1/4" ANSI 2500 lbs
E 1 1/2" ANSI 2500 lbs
9.2 Surface open drain flange
0 without
C Standard-Surface RF
F Surface Form E Rz=16
G Surface RFSF (smooth finished)
H Surface groove large
I Surface tongue-large
J Surface RTJ (ANSI)
10. Float pipe top end finish
0 End cap
1 Flange with blind flange DN 50 PN 320
A Flange with blind flange 2" ANSI 2500 lbs
10.1 Surface float pipe top end finish flange (only DN50 or 2")
0 without
C Standard-Surface RF
F Surface Form E Rz=16
G Surface RFSF (smooth finished)
H Surface groove large
I Surface tongue-large
J Surface RTJ (ANSI)
10.2 Bolts & nuts float pipe top end finish flange
0 without
61 M24 x 150 mm; mat. steel zinced; Flange DN 50 PN 320
62 M24 x 150 mm; mat. SS 1.4301; Flange DN 50 PN 320
6X M24 x 150 mm; PTFE coated; Flange DN 50 PN 320; DIN 2510
FA 7/8" x 150 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 1500 lbs, ANSI B16.5
FB 7/8" x 150 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FC 7/8" x 160 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 1500 lbs; ANSI B16.5
FD 7/8" x 150 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FT 7/8" x 160 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 1500 lbs, ANSI B16.5
FV 7/8" x 160 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 1500 lbs; ANSI B16.5

185
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-13 & ITA-13.0 PN320/2500 lbs

Order codes for mag. level gauge type ITA-13 & ITA-13.0 PN320/2500 lbs

Code Description

11. Vent plug at top end


0 without
1 Vent plug G1/2" with soft iron gasket
2 Vent plug 1/2" NPT
3 Vent plug 3/4" NPT
4 Vent plug 1" NPT
11.1 Vent flange welded to end cap instead of vent plug
0 without
1 Flange DN 15 PN 320 (socket weld construction to endcap)
2 Flange DN 25 PN 320 (socket weld construction to endcap)
3 Flange DN 32 PN 320 (socket weld construction to endcap)
4 Flange DN 40 PN 320 (socket weld construction to endcap)
A Flange 1/2" ANSI 2500 lbs (socket weld construction to endcap)
B Flange 3/4" ANSI 2500 lbs (socket weld construction to endcap)
C Flange 1" ANSI 2500 lbs (socket weld construction to endcap)
D Flange 1 1/4" ANSI 2500 lbs (socket weld construction to endcap)
E Flange 1 1/2" ANSI 2500 lbs (socket weld construction to endcap)
11.2 Vent flange with concentric reducer (X-ray testing)
0 without
1 DN 15 PN 320
2 DN 25 PN 320
3 DN 32 PN 320
4 DN 40 PN 320
A 1/2" ANSI 2500 lbs
B 3/4" ANSI 2500 lbs
C 1" ANSI 2500 lbs
D 1 1/4" ANSI 2500 lbs
E 1 1/2" ANSI 2500 lbs
11.3 Surface vent flange welded to end cap (only DN50 or 2")
0 without
C Standard-Surface RF
F Surface Form E Rz=16
G Surface RFSF (smooth finished)
H Surface groove large
I Surface tongue-large
J Surface RTJ (ANSI)
12. Counter flanges
0 without
1 DN 15 PN 320
2 DN 25 PN 320
3 DN 32 PN 320
4 DN 40 PN 320
5 DN 50 PN 320

186
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-13 & ITA-13.0 PN320/2500 lbs

Order codes for mag. level gauge type ITA-13 & ITA-13.0 PN320/2500 lbs

Code Description

12. Counter flanges (Continuation


A 1/2" ANSI 2500 lbs
B 3/4" ANSI 2500 lbs
C 1" ANSI 2500 lbs
D 1 1/4" ANSI 2500 lbs
E 1 1/2" ANSI 2500 lbs
F 2" ANSI 2500 lbs
12.1 Surface counter flanges
0 without
C Standard-Surface RF
F Surface Form E Rz=16
G Surface RFSF (smooth finished)
H Surface groove large
I Surface tongue-large
J Surface RTJ (ANSI)
12.2 Bolts & Nuts counter flanges
0 without
61 M24 x 150 mm; mat. steel zinced; Flange DN 50 PN 320
62 M24 x 150 mm; mat. SS 1.4301; Flange DN 50 PN 320
6X M24 x 150 mm; PTFE coated; Flange DN 50 PN 320; DIN 2510
FA 7/8" x 150 mm; RF; mat. A193B7/A1942H zinced steel; flange 2" ANSI 1500 lbs, ANSI B16.5
FB 7/8" x 150 mm; RF; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FC 7/8" x 160 mm; RTJ; mat. A193B7/A1942H zinced steel, flange 2" ANSI 1500 lbs; ANSI B16.5
FD 7/8" x 150 mm; RTJ; mat. A193B8 / A1948M SS; flange 2" ANSI 1500 lbs, ANSI B16.5
FT 7/8" x 160 mm; RF; mat. A193B8 / A1948M PTFE-coated; flange 2" ANSI 1500 lbs, ANSI B16.5
FV 7/8" x 160 mm; RTJ; mat. A193B8/A1948M PTFE-coated, flange 2" ANSI 1500 lbs; ANSI B16.5
13. Additional bracket welded to the float pipe
0 without
H Bracket

187
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


ITA-13 & ITA-13.0 PN320/2500 lbs
Float pipe: 1.4571 flange: 1.4404

Order codes for mag. Level Gauges type: ITA-13.0 PN320/2500 lbs

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
13V330K3 320 316L 38 325 0,7269 Y only with 316SS or Aluminium indication rail
13T324K3 320 Titanium 38 265 0,5366 Y only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds

13T024K3 320 Titanium 38 265 0,8985 N only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds

13T330K3 320 Titanium 38 325 0,5032 Y only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds

13T040K3 320 Titanium 38 425 0,7582 N only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds

13T050K3 320 Titanium 38 525 N only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds

For additional accessories please refer to the chapters "Special equipment" and "Electrical accessories and Switches"

188
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

3.22.4 Order code scheme for ITA-13 & ITA-13.0

1. Type of level gauge ITA-13 or ITA-13.0


2. C to C distance in mm [or inches]
3. Design
4. C to C distance > 5000 mm
5. Process connection [side/side]
5.1 Surface side flanges
6. Side studs welded with T-pieces for 100 % X-ray-testing
7. Float removal flange
7.1 Surface float removal flange
7.2 Bolts & nuts float removal flange
8. Drain plug
9. Additional drain flange, open

ITA-13

ITA-13.0

9.1 Drain flange with concentric reducer (X-ray testing)


9.2 Surface open drain flange
10. Float pipe top end finish
10.1 Surface top end finish flange
10.2 Bolts and nuts rop end finish flange
11. Vent plug at top end
11.1 Vent flange welded to end cap instead of vent plug
11.2 Vent flange with concentric reducer (X-ray testing)
11.3 Surface vent flange welded to end cap
12. Counter flanges
12.1 Surface counter flanges
12.2 Bolts & nuts counter flanges
13. Additional bracket welded to the float pipe
14. Float

189
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

4. Equipment

4.1 ITA-3 Cryo


‡ D
If Armaflex is used for insulation (t=9 mm) the 9
material for the indication rail will be
aluminium. As standard for the level gauge in
Cryo-design we use a float chamber ‡60,3x2
mm with a float from titanium (‡50,8x240 mm
length) down to a liquid density of 0,6 kg/dm³.
For temperatures below –40°C the Armaflex
insulation is double ply, the upper layer only
up to the indication rail.

The customer should also insulate the process


flanges.
For vaporizing media (for example ammonia)
w recommend to use floats with 4 distance
sleeves (In this case the floats are smaller
than standard floats). This construction
prevents catapulting the float upwards (this
would cause switch failures) if gas evolution
appears.
For temperatures down to –20°C we are using
a float chamber ‡60,3x2 mm and a titanium
float ‡45x400 mm, for temperatures below –
20°C we are using a float chamber ‡64x2mm
and a titanium float ‡50,8x500 mm.
In every case we use flanges DN50 as drain
connections (weld neck and blind flanges with
groove and tongue). When the dimension of
the float chamber is ‡64x2 mm, it is
necessary to modify the weld neck flange.
On request by the customer we make use of
small hole (throttling part) to transmit the liquid 240
level to the float chamber. It stabilizes the float (500)
movement (damping).

throttling part dependence on the temperature:


‡4 mm for T -20°C
‡ 2 mm for T < -20°C

distance sleeve
190
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

£-Insulation
4.2 Armaflex£

191
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

4.3 Heat insulation

Isolation and sealing material:


made of e-glassyarns

Technical data:
Composition in %: : 53 % SiO2, 16 % CaO, 13 % Al2O3, 7 % B2O3,
4 % MgO, 1 % Na2 + K2O
Portion organic substance : < 1 % (combust at first heating-up)
Density (g/cm³) : 2,5
Temperature resistance : 500°C/550°C
Degree of moisture : 1%
Annealing loss : 0,6%
Shrinking : 500°C = 0 %
Resistance against : Oil, grease, water, temporary steam
and numerous organic acids/solvents.
Good resistance against sudden heat waves. Good
thermal electrical and acoustical insulation
resistance:
Toxicologically harmless
No handling abligations

192
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

4.4 Technical data Switches

1. General table

Switch 1690 1690ATEX LMS-A LMS-A-EExd MS09K MS10 EExd


Part-no. 641.6502.380LI 610.045N1001 ---- ---- ---- ----
Housing synthetic synthetic Al Si 12 Al Si 12 synthetic Aluminium
Contact bistable bistable bistable bistable break-or make- break-or make-
Function change-over change-over change-over change-over contact, contact,
contact contact contact** contact change-over change-over
contact contact
Dimensions 20x15x80 20x15x80 65x65x40 ‡138x80 110x75x50 120x120x110
Breaking on 230 V AC/DC 230 V AC/DC 220 VAC 220 VAC 250 VAC 250 VAC
rupturing 40 W 45 W
capacity 0,8 A 0,4 A 1,5 A 1,5 A 10 A 10 A
60 VA 45 VA 80 VA 80 VA ---- ----
Protective IP65 IP65 IP65 DIN 40050 IP65 DIN 40050 IP65 DIN 40050 IP65 DIN 40050
System
Option IP67 DIN40050 IP67 DIN40050 ---- ---- ---- ----
Switch- 15 mm 15 mm 8…12 mm 8…12 mm ---- ----
hysteresis
Medium max. 130 °C max. 130 °C max. 200 °C* max. 200 °C max. 100 °C max. 200 °C
temperature
EEx- ---- EEx m II CT6 ---- EEx d II CT6 ---- EEx d II CT6
protection
Connection ---- ---- PG7,5 4 connection PG11 3/4" NPT
(3/4" NPT)
Electric connection with 3-channel plug and earth.
For all switches the international standard EN 60529 is valid.
*Type LMS-A in heat protection version can stand a max. temp. of 400 °C
**available with gold contact

2. NI Ex NJ switch

Inherent safety EEx-switch, on request with define error message.

Contact- Supply voltage: 8 V DC


transmitter Max temperature: 60 °C
Cable connection at housing: PG11
Section Supply voltage: 220 V + 15 % (45…60 Hz)
switch Power consumption: appr. 1,5 V
appliance Open circuit voltage: 8 V DC
Allowed charge: 4 A/250 V/250 VA
Allowed temperature: -20…+60°C

3. Switch diagrams

Types: 1690, 1690ATEX, LMS-A, LMS-A-EExd, MS09K and MS10 EExd:

bistable change-over contact

193
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Switch LMS-A Switch LMS-AH

Switch 1690 / 1690ATEX Switch MS09K

Switch MS10 EExd Switch LMS-A-EExd

194
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Switch Ni Ex NJ

Switch NI-Ex-NJ

195
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

4.5 Contact NJ-EX

The contact NJ-EX is an inductivbe contact NJ 1.5-6.5 N, kontex system,


protective system EEx ia IIC T6.

Function:

Actuation is provide by the magnet installed in the


float. The follow magnet system of the contact
maker moves the switching disk, which serves for
releasing the contact between two small
inductances of the slotted initiator and thereby
varies the attenuation of the resonant circuit.

Technical data:

Electrical connection: 8 V DC
Temp./ambient temp. 60 °C
Cable connections: M20x1,5

Swich relay:

KFA6-SR2-Ex1.W: for 1 inductive contact EEx ia IIC


KFA6-SR2-Ex2.W: for 2 inductive contacts EEx ia IIC

196
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

4.6 Indication rails

Armaflex-insulation and heating tape ITA Indication rail with scale for ITA

Indication rails:
Makrolon Aluminium 316SS

1. Sealing cap 1. U-profile 1. U-profile


2.Indication lamina with magnet 2. Indication lamina with magnet 2. Indication lamina with magnet
3. Rectangualr profile 3. Transparent covering 3. Transparent covering
4. U-profile 4. Hermetically sealed 4. Hermetically sealed

197
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

4.7 Niveau-source

Measuring principle:
The resistance chain with the reed contacts are built in a pipe made of material 316SS. This so-called “Reed-chain”
is mounted on the float chamber with tube clamps. According to the movement of the float, the float magnet closes
one reed contact which produces a voltage (or resistance) proportional to the height of the liquid in the tank.
You get a near-analogous output signal, with a resolution of about 10 mm.
The resistance chain receives it’s power supply from the transmitter. The 4...20 mA transmitter output signal can be
transferred to an indicator or can be used to drive alarm contacts. In the case of an error the output signal becomes
higher than 22 mA.

Connection:
As a standard, the reed chain is supplied with a transmitter that is installed inside the housing-head, 2-wire
connection to the transmitter is only required.

198
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

4.8 Reed-contact

Standard-reed chain Reed chain for higher temperature


Max. medium temperature: 150 °C Max. medium temperature: 400 °C
Protection pipe: ‡ 14 mm Protection pipe: ‡ 14 mm
Material: 316Ti Material: 316Ti
Housing: IP65 Housing: IP65
Heat protection: 50x4 mm

Clamp (standard) Clamp (special)


Will be needed by Armaflex insulation and
secondary mounting of a reed chain.

199
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

4.9 Digital Indication with mag. Level Gauges type ITA and Reed-Chain type AVK

Electrical measurement transducers with use the displacement principle have to be re-calibrated each time the fluid
density is changed.

The price of a magnetically controlled level indicator with integral electical measurement transducer is considerably
lower than level measurement transducers.

The reed chain with an R/I-measurement transducer can be replaced without interrupting operation. The measurement
chamber is hermetically sealed - there is non contact between the fluid to be measured and the reed chain.

With the field mounted loop powered indicator, the level can be displayed digitally at the place of measurement.

200
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

4.10 Field mounted loop powered Indicator type 8080HT

Features:
 4..20 mA-input, loop powered
 4-digit LED display in engineering units
 Aluminium or 316SS housing

Introduction:
Model 8080HT Loop Powered Digital Indicators allow the process variable from any 4…20 mA current source to be
monitored. Since the unit derives its power from the loop, no additional power supply or wiring is needed. Because
of its low voltage drop (5.3 Volts at 20 mA), it can be incorporated into almost any 2-wire-loop, where local
indication of a process variable is needed, because the integral transmitter indicatore inaccessible to view or is at
a different location.

Description:
Model 8080HT Indicators are designed for use in process industries where vibration, inclement weather and corrosive
atmospheres prevail.The electronics are enclosed in a copper-free epoxy-coated Alumiium housing and for more
aggressive environments, a SS316 housing is available. The housings meet the requirements of NEMA 4X and are
also certified Explosion Proof by FM/CSA.

LED Meter:
The Model 8080HT has a 4-digit display and may be configured to read -999 to 9999 with a 4…20 mA input signal.
The decimal point location and engineering units can be adjusted using membrane switches, eliminating all
potentiometric adjustments.

Specifications:
 Indication accuracy: 0.1 % of calibrated range ± 1 digit
 Calibration: via membrane switches on the front panel
 Display height: 10 mm high LED, user-selectable decimal point
 Stability over time: 0.1 % of calibrated range ± 1 digit over 6 months
 Over-range indication: Indication fo "HHHH" or "LLLL" blinking on the display
 Response time: 0.3~0.5 s
 Failure mode: Failure will not affect the loop integrity
 Voltage drop: 5.3 Volts at 20 mA
 Operating temperature: -50…75 °C
 Weight: 0.9 kg (2 lb) Aluminium unit / 1.4 kg (3 lb) 316SS unit
 Material of construction: Encl.: epoxy-coated copper-free aluminium or 316 SS
 O-Rings: BUNA N

201
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Dimensions of the 8080HT field indicator:

202
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

4.11 Magnetostricitve level transmitter

M-500 / M-600

Magnetostrictive transmitter for mounting to a level gauge


type ITA.

M-500/M-600 series working on the magnetostrictive principle is


high accuracy transmitter for affordable price. The float inside the
level gauge type ITA moves along the magnetostrictive wire. A
pulse generated by the electronics travels along the wire. When
the pulse reaches the float's magnetic field, a twist develops in
the wire. Reflected form the torsion point, the pulse creates an
acoustic wave that travels back along the wire. The 4…20 mA
output from the transmitter is proportional to the level.

Technical data:

Type: rigid version flexible version


principle/design magnetostrictive 2- wire transmitter
measured
process values
level, interface level
sensor length 0,5…4,5 m 2…10 m
materials sensor: 316Ti (1.4571), housing: Aluminium, powder paint coated or plastic (PTB)
max. pressure depends on the level gauge type ITA
temperature medium: max. 90°C (+400 °C for high-temperature-version)
ambient: -40 °C..+70 °C
linearity with
dry calibration
± 1 mm
resolution 0,1 mm or 1 mm (order-dependent)
temperature
coefficient
0,04 mm/°C
measuring range min. 200 mm
medium density depends on the level gauge type ITA
outputs analogue: 4…20 or 20…4 mA
serial: HART interface /min. loop resistance: 250 Ohm
display: 6 digits (7 mm characters) icons, units and bargraph
damping 0…60 s, programmable
error indication 3,8 mA or 22 mA
output load Rt=(Us-12,5V)/0,02A; Us = voltage of power supply
power supply 12,5…36 V DC
ATEX approval Ex II 1 G EEx ia IIB T6…T5
Ex II2G EEx d IIV T6…T5
Ex II1/2G EEx d ia IIB T6…T5
intrinsically
safe area
Ex II
electric: class III
protection ingress: IP67
electrical cable gland PG16 or M20x1,5
connection cable diameter: 8…15 mm, wire cross section: max. 1,5 mm²
weight: 1,7 kg + sensor (sensor = 0,6 kg/m) 2,9 kg + sensor (sensor=0,3 kg/m)

Temperature classification for Ex-Application:


Temperature class ambient temperature process temperature
T6 -25…+70 °C
T5 -25…+59 °C max. 400 °C, because no wetted parts
T4 -25…+45 °C

203
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Order specifications:

M Magnetostrictive Level Transmitter


Function /sensor design (depends on tube length)
T with transmitter /rigid (0,5…3m); flexible (> 3 m)
B with transmitter and display /rigid (0,5…3m); flexible (> 3 m)
Connection to level gauge type ITA
U Direct welded clamps (stainless steel)
UX Hose clamps (stainless steel)
-
Material electronic housing
5 Aluminium (powder paint coated)
6 Plastic (PTB fiber-glass reinforced, flame retardant
Measuring length
ML measuring length in mm
-
Output /resolution /approval
2 4…20 mA /1mm
4 4…20 mA; Hart /1mm
6 4…20 mA /1mm /Ex
8 4…20 mA; Hart /1mm /Ex
A 4…20 mA /5mm
E 4…20 mA; Hart /5mm /Ex

M - -

204
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

4.12 Transmitters

Available housings Available transmitters

Standard-transmitter- Type: INT5333B


housing i EEx ia IIC T5/T6
i material: aluminium i output: 4…20 mA
i PG 16 entry i power supply:
2…36 V DC
i linearity: ± 1 %

EExd-transmitter- Type: TMT182


housing i EEx ia IIC T4
i material: aluminium i output: 4…20 mA
epoxy coated (Hart-protocol)
i 1/2" NPT cable entry i power supply:
13…30 V DC
i linearity:
ȍDUHD“ȍ
ȍDUHD“ȍ
i input:
«ȍ«ȍ

Stainless steel
transmitter housing Other types of transmitters on request!
i material: 316Ti
i M20x1,5 entry

205
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Transmitter type INT5333

INT5333
2-wire
programmable transmitter

2-WIRE PROGRAMMABLE TRANSMITTER


INT-5333

i RTD or Ohm infput


i High measurement accuracy
i 3-wire connection
i programmable sensor error value
i for DIN form B sensor head mounting

Application:
- Linearized temperature measurement with Pt100…Pt1000 or Ni100…Ni1000
sensor
- Conversion of linear resistance variation to a standard analogue current signal,
for instance from valves or Ohmic level sensors.

Technical characteristics:
- within a few seconds the user can program the INT5333 to measure temperatures
with all RTD ranges defined by the standards.
- The RTD and resistance inputs have cable compensation for 2- and 3-wire
connection.

Mounting/Installation:
- For DIN form B sensor head or DIN rail mounting with a special fitting.

206
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Order information:
Type Version
INT5333 Standard: :A
EEx: :B
FM and EEx: :C
Electrical specifications:
Specification range:
-40…+85 °C
Common specifications:
Supply voltage, DC
Standard, INT5333A 8…35 V
EEx and FM, INT5333B and C 8…28 V DC
Internal consumption 35 mW…0,8 W
Voltage drop 8 V DC
Warm-up time 5 min.
Communications interface Loop Link 5905
Signal/noise ratio min. 60 dB
Response time (programmable) 0,33…60 s
Signal dynamics, input 19 bit
Signal dynamics, output 19 bit
Calibration temperature 20…28 °C
Accuracy, the greater of general and basic values:
General values
Input type: Absolute accuracy Temperature coefficient
all d± 0,1 % of span d± 0,1 % of span / °C

Basic values
Input type: Basic accuracy Temperature coefficient
RTD d± 0,3 °C d± 0,01 °C / °C
Lin. R. d“ȍ d“ȍƒ&

EMC immunity influence d± 0,5 % of span


Effect of supply voltage d± 0,005 % of span / V DC
Vibration: IEC 68-2-6 Test FC
Lloyd's specification no. 1 4 g / 3…100 Hz
Max. wire size 1 x 1,5 mm²
Humidity < 95 % RH (non-cond.)
Dimensions ‡44 x 20,2 mm
Tightness (enclosure/terminal) IP68/IP00
Weight: 50 g
Electrical specifications, input:
RTD-type min. value max. value min. span
Pt100 -200 °C +850 °C 25 °C
Ni100 -60 °C 250 °C 25 °C
Lin.R. ȍ ȍ ȍ

207
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

RTD and linear resistance input:


Max. offset 50 % of selected max. value
Cable resistance per wire (max.) ȍ
Sensor current > 0,2 mA < 0,4 mA
Effect of sensor cable resistance (3-wire) ȍȍ
Sensor error detection Yes

Output:
Current output:
Signal range 4…20 mA
Min signal range 16 mA
Updating time 135 ms
Load resistance d (Vsupply >ȍ@
Load stability “RIVSDQȍ

Sensor error detection:


Programmable 3,5…23 mA
NAMUR NE 43 upscale 23 mA
NAMUR NE 43 downscale 3,5 mA

Ex data:
Ui 28 V DC
Ii 120 mA DC
Pi 0,84 W
Li d 10 μH
Ci d 1 nF

EEx approval CENELEC:


DEMKO 03 ATEX 13705X
ATEX 0539 Ex II 1 GEExia IIC T1…T6
max. amb. temperature for T1…T4 85 °C
max. amb. temperature for T5 and T6 60 °C
Applicable in zone: 0, 1 or 2
FM IS, Cl.I, Div.1 Gp.A-D
Entity, FM control drawing no. 5300Q502

Observed authority requirements: Standard:


EMC 89/339/EEC
Emission EN50081-1, EN50081-2
Immunity EN50082-2, EN50082-1
ATEX 94/9/EC EN50014 and EN50020
FM class number 3600, 3610

Of span: of the presently selected range

208
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Transmitter type TMT84 (Profibus)

Resistance transmitter
Type: TMT84
Head transmitter with Profibus-PA££ interface. Supply and digital communication using
PROFIBUS-PA£ £, for installation in a form B sensor head.

Features and benefits:


- Universally programmable for various input signals using PROFIBUS-PA£.
- DIP switch fro address setting (as option)
- High accuracy in the total ambient temperature range
- EMC to NAMUR NE 21, CE
- Certification:
- ATEX
- FM
- CSA
- PROFIBUS-PA profile V3.0
- Galvanic isolation
- Customer specific address setting or expanded setup (see questionnaire page)

Application areas:
- Applied in a PROFIBUS-PA£ environment, the process industry fieldbus, an open standard to
EN50170 and IEC 61158-2
- Temperature head transmitter with PROFIBUS-PA£ protocol for converting various input signals
into a ditigal output signal
- Input:
- Resistance thermometer (RTD)
- Thermocouple (TC)
5HVLVWDQFHWUDQVPLWWHU ȍ
- Voltage transmitter (mV)
- Swift and easy operation, visualization and maintenance using a PC direct from the control panel,
e.g. using the COMMUWIN II operation software.

209
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Operation and system construction


Measurement principle
Electronic measurement and conversion of input signals in industrial temperature measurement.
Measurement system
p p
and
resistance transmitters in 2-, 3- or 4-wire connection, thermocouples and voltage transmitters. Applications are in the
measurement and control areas for process monitoring. The TMT184 setup is done using the PROFIBUS-PA£ protocol
combined with a PC operating software (e.g. COMMUWIN II).
PROFIBUS-PA£ is a open field bus standard in
accordance with EN50170 and IEC61158-2, which has
been specifically designed to handle the requirements of
the process industry. In the simplest case a
complete measurement circuit consists of a TMT184 fitted into
a temperature sensor, a segment coupler, a
PROFIBUS-PA£ connection resistance, a PLC or a PC with an
operating software.
The maximum number of transmitters that can be
connected per bus segment is determined by the
transmitter consumption, the maximum power of the
segment coupler as well as the required bus length.
Normally:
- max. 9 TMT184 in an EEx ia explosion hazardous area per bus segment.
- max. 32 TMT184 in a non-explosion hazardous area per bus segment.

More detailed information for detailed project planning can be found in the operating manual.

Input values
Measurement value: Temperature (temperature linear), resistance and voltage
Measurement range: Dependent on the sensor connection and input signal the transmitter
evaluates a number of different measurement ranges.
Type of input:

210
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Output values

Output signal
Physical data transmission (Physical layer type):
Fieldbus interface in acc. to IEC 61158-2.

Failure signal
Status message acc. to the PROFIBUS-PA£ profile V3.0 specification.

Galvanic isolation
2 kV AC

Filter
Digital filter 1st degree 0...60 s

Current consumption
10 mA r 1 mA

Error current
0 mA

Switch on delay
- 10 s

Data transmission speed


31,25 kBit/s, voltage mode

Signal code
Manchester II

Auxiliary energy

Electrical connection

Head transmitter terminal layout

Power supply
Ub = 9...30 V DC non Ex area, polarity protected
Ub = 9...15 V DC Ex area, polarity protected

211
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Accuracy

Response time: 1s

Reference conditions: Calibration temperature: +23 °C ± 5 K

Maximum measured error:


Type: Measurement accuracy
Pt100, Ni100 0,15 K
Resistance Thermometer (RTD) Pt500, Ni500 0,5 K
Pt1000, Ni1000 0,3 K
K, J, T, E, L, U typ. 0,5 K
Thermocouple (TC) N, C, D typ. 1,0 K
S, V, R, MoRe5-MoRe41 typ. 2,0 K

Meas. accuracy: Measurement range


5HVLVWDQFH7UDQVPLWWHU ȍ “ȍRU «ȍ
“ȍRU «ȍ
Voltage Transmitter (mV) 20 μV or 0,08 % -10…75 mV

Influence of ambient Resistance thermometer:


temperature (temperature Td “ SSP. PD[PHDVUDQJHSSP. SUHVHWPHDVUDQJH ǻG
drift): Thermocouple
Td “ SSP. PD[PHDVUDQJHSSP. SUHVHWPHDVUDQJH ǻG
ǻG = Deviation fo the ambient temperature according to the reference condition.
Long term stability: d 0,1 K/year or d 0,05 %/year

Influence of reference Pt100 DIN IEC 751 Cl. B (internal reference junction for thermocouples)
junction:

Application conditions (installation conditions)

Installation hints: - installation angle: no limitations

- installation area:
connection head acc. to DIN 43729 Form B; field housing TAF 10

Application conditions (ambient conditions)

Ambient temperature: -40…+85 °C (for hazardous area see Ex-certificate)

Storage temperature: -40…+100 °C

Climate class: acc. to EN 60654-1, Class C

Condensation: allowable

Ingress protection: IP00, IP66 installed

Shock and vibration 4g/2…150 Hz acc. to IEC 60068-2-6


resistance:

Electromagnetic Interference immunity and interference emission acc. to EN 61326-1


compatibility (EMC): (IEC 1326) and NAMUR NE 21

212
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mechanical construction

Dimensions:

Head transmitter (dimensions in mm)

Weight: approx. 40 g
Material: - housing: PC
- potting: PUR

Terminals: cable up to max. 1,75 mm² (secure screws)

Display and operating system

Remote operation
Operation via PROFIBUS-PA£ using a suitable configuration or operating software.

Certification

Ex-certification
Details regarding the availability of the Ex-versions (ATEX, FM, CSA etc.) can be obtained from your
local sales organization. All relevant data for hazardous area protection can be found in separate Ex-
documentation, which can be requested separately.

CE marking
The measurement system complies with the legal requirements laid out within the EU regulations.

213
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Ordering codes TMT84:

Code Description
TMT84 Head Transmitter
Temperature transmitter with 2 sensor inputs and enhanced diagnosis functions for sensor monitoring.
PROFIBUS-PA£ protocol profile 3.01; Galvanic isolation 2 kV (input/output)
$SSOLFDWLRQ57'7&ȍDQG09&RQVXPWLRQPD[P$,QVWDOODWLRQFRQQHFWLRQKHDGIRU%
acc. to DIN 43729; UL listed, CSA general purpose
Approvals / Certifications:
A1 ex-free area
B1 ATEX II 1G Ex ia IIC T4/T5/T6
B2 ATEX II 3G Ex nA IIC T4/T5/T6
B3 ATEX II 3D
B4 ATEX II 1G Ex ia IIC T6, II 3D
B5 ATEX II 3G Ex nA IIC T6, II 3D
CA FM+CSA IS, NI I/1+2/ABCD
C1 FM IS, NI I/1+2/ABCD
C2 CSA IS, NI I/1+2/ABCD
D1 NEPSI Ex ia IIC T4/T5/T6
D2 TIIS Ex ia IIC T6
E1 IECEx Ex ia IIC T4/T5/T6
Communication, output signal
A PROFIBUS-PA£
Electrical connection
1 Spring terminals
2 Screw terminals
9 Special version, please specify
Mounting parts
A Standard-DIN mounting set
B US-M4 mounting screws

TMT84 <== Ordering code [part 1] - 1 option each category has to be chosen

Additional options- no or multiple choice allowed.

Configuration input:
A1 Ch1: RTD 2-wire, Ch2: not active
A2 Ch1: RTD 2-wire, Ch2: RTD 2-wire
A3 Ch1: RTD 2-wire, Ch2: RTD 3-wire
A4 Ch1: RTD 2-wire, Ch2: TC
B1 Ch1: RTD 3-wire, Ch2: not active
B2 Ch1: RTD 3-wire, Ch2: RTD 2-wire
B3 Ch1: RTD 3-wire, Ch2: RTD 3-wire
B4 Ch1: RTD 3-wire, Ch2: TC
C1 Ch1: RTD 4-wire, Ch2: not active
C2 Ch1: RTD 4-wire, Ch2: TC
D1 Ch1: TC, Ch2: not active
D2 Ch1: TC, Ch2: TC
Display + Operation
E1 meas. Value indication & dip switch, attachable (TID10)
Calibration + Test
F1 Works calibration cert. 6-point (fixed points)
Tagging
X1 TAG, field bus
X2 TAG, paper (3 lines, each 16 characters)
X3 TAG, metal (2 lines, each 16 characters)
X4 Bus address (PA: 0…126)
X5 TAG on transmitter

TMT84

214
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Questionnaire TMT84 temperature transmitter


Customer specific setup
Standard setup

Channel 1 (Ch1) Channel 2, Ch2

RTD Pt50, GOST Ni100, DIN 43760 RTD Pt50, GOST Ni100, DIN 43760
Pt100, IEC751 Ni120, Edison Curve Pt100, IEC751 Ni120, Edison Curve
Pt100, JIS C1604-81 Ni1000, DIN 43760 Pt100, JIS C1604-81 Ni1000, DIN 43760
Pt100, GOST Pt100, GOST
Pt200, IEC 751 Cu10 Edison Curve no. 15 Pt200, IEC 751 Cu10 Edison Curve no. 15
Pt500, IEC 751 Cu50, GOST Pt500, IEC 751 Cu50, GOST
Pt1000, IEC 751 Cu100, GOST Pt1000, IEC 751 Cu100, GOST

TC B E J K TC B E J K
IEC584 IEC584
N R S T N R S T

C D ASTM E988 C D ASTM E988

L U DIN 43710 L U DIN 43710

Unit
°C °F

Interconnection*

PV1 = Ch1; PV2 = Ch2 (default)


PV1 = Ch1-Ch2; Difference value
PV1 = 0,5 x (Ch1+Ch2), Average value
PV1 = Ch1 (or Ch2) Backup

*only if Channel 2 is active

215
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


Special equipment & Accessories

Order Codes for Electronic Accessories and Switches

Code Description
Switches
mag. switch type 1690, 3 m cable
S10 Protection class: IP68, max. operation temperature: 120°C
(Art.-No. 641.6502.380LI)
mag. switch type 1690 ATEX , 3 m cable
S20 Protection class: IP67 BVS03 ATEX, max. operation temperature 120°C
(Art.-Nr. 610.045N1001)
SXK Cable length > 3 m, each additional m (please specify)
SXS Hose clamp for switch 1690 and 1690 ATEX
Mag. switch type LMS-A
S30
Protection class IP65, max. operation temperature: 200°C (without special equipment)
S3G Mag. switch type LMS-A with gold plated contacts 8 VDC
S3D Mag. switch type LMS-A mounted in EExd housing
S3E Mag. switch type LMS-A with gold plated contacts 8 VDC
S40 Mag. switch type: LMS-AH
S4G Mag. switch type LMS-AH with gold plated contacts 8 VDC
S4D Mag. switch type LMS-AH mounted in EExd housing
Mag. switch type LMS-AH with gold plated contacts 8 VDC
S4E
+ mounted in Eexd housing
Mag. switch type NI-EX with P&F proximation initiator acc. NAMUR
S50
Protection class IP65 EExia ATEX, max. operation temperature: 60 °C
Mag. switch type NI-EX with P&F proximation initiator acc. NAMUR
S5H
with additional heat protection, max. operation temperature: 400 °C
Switch type MS9, with micro switch and additional heat protection
S6H
max. operation temperature: 400°C
Switch type MS10, with micro switch
S70 Protection class IP65, max. operation temperature: 200°C, max. 250 VAC/10A
mounted in Eexd housing
Switch type MS10, with micro switch with additional heat protection
S7H Protection class IP65, max. operation temperature: 400°C, max. 250 VAC/10A
mounted in Eexd housing
S80 Switch type MAK 9924
Cable entry for switch (all switches, except 1690/1690ATEX)
1 M20 x 1,5
2 1/2" NPT
3 3/4" NPT
Isolation amplifier for NI-EX switch
T01 Isolation amplifier for NI-EX switch; type: KFAG-SR2-EX1.W; one channel
T02 Isolation amplifier for NI-EX switch; type: KFAG-SR2-EX2.W; two channels

216
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


Special equipment & Accessories

Order Codes for Electronic Accessories and Switches

Code Description
Reed chain
R05 Reed chain, resolution 5 mm, base price
L add. price each 100 mm
0 without heat protection
H with heat protection, max 400 °C / each 100 mm
R10 Reed chain, resolution 10 mm, max. 150 °C, base price
L add. price each 100 mm
0 without heat protection
H with heat protection, max 400 °C / each 100 mm
R20 Reed chain, resolution 20 mm, base price
L add. price each 100 mm
0 without heat protection
H with heat protection, max 400 °C / each 100 mm
RXS Clamps for reed chain / 2 pcs.
Transmitter
M10 Transmitter type: INT5333A
M11 Transmitter type: INT5333A with ExD-housing
M12 Transmitter type: INT5333A with stainless steel housing
M20 Transmitter type: INT5333B EX intrinsically safe
M22 Transmitter type: INT5333B EX intrinsically safe with stainless steel housing
M30 Transmitter type: INT5335A SMART/HART-technology
Transmitter type: INT5335B Ex-proof with SMART/HART-technology
M32
with stainless steel housing
M33 Transmitter type: INT5350B with Foundation Fieldbus
M35 Transmitter type: INT5350B with Foundation Fieldbus; EExia ATEX
M34 Transmitter type: TMT142 with Foundation Fieldbus and digital indicator
0 without Ex-protection
1 EExia ATEX
Transmitter type STT 3000 with digital indicator
M36
electr. Class EExd; output 4…20 mA
Cable entry for transmitter housings
1 M20 x 1,5
2 1/2" NPT
3 3/4" NPT
Digital indicator
Digital indicator mounted in transmitter housing (only with reed-chain)
D10
DSM-40-indicator, standard version input 4-20 mA; display ± 19999
Digital indicator mounted in transmitter housing (only with reed-chain)
D11
DSM-40-indicator, standard version input 4-20 mA; display ± 19999; EEx-version
D20 Digital indicator IA-N24-S, input 4-20 mA; 24 VDC for 2-wire-transmitters
Digital indicator IA-N30U, input 4-20 mA; 24 VDC for 2-wire-transmitters
D21
add. 4-20 mA-output
Digital indicator IA-N30U, input 4-20 mA; 24 VDC for 2-wire-transmitters
D22
add- 2 off. contacts
Digital indicator IA-N30U, input 4-20 mA; 24 VDC for 2-wire-transmitters
D23
add. 2 off contacs and 4-20 mA-output

217
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


Special equipment & Accessories

Order Codes for Electronic Accessories and Switches

Code Description
Electronic heat tape
Electronic heat tape without Ex-protection, base price
H10
add. price each 100 mm
H11 Electronic heat tape connection set
H12 Electronic heat tape connection socket, material CS
Electronic heat tape, Ex-version
H20
add. price each 100 mm
H21 Electronic heat tape connection set Ex-version
H22 Electronic heat tape connection socket, material CS / EExd housing
H23 Electronic heat tape thermostat Ex-version
H30 Electronic heat tape for high temperature applications (> 200 °C)
H31 Electronic heat tape for high temperature applications (> 200 °C), Ex-Version
Power supply
SG1 Power supply 220 V / 50 Hz
Indication rail
Aluminium indication rail coated (Epoxy-coat: Saekaphen); colour: white
Z01
add. price each 100 mm
Measuring scale
Graduated scale, graved, material: 316SS, base price
Z02
add. price each 100 mm:
Graduated scale, graved, material: Aluminium, base price
Z02
add. price each 100 mm:
Steam jacket
Steam jacket, max. 6 bar, threaded connection, material 1.4404 (only available with
Z05
add. price each 100 mm:
Steam jacket, max. 6 bar, flanged connection DN 15 PN 16 (1/2" 150#),
Z06
add. price each 100 mm:
Vent/drain fittings
Z07 Vent-/drain valve 1/2" NPT / material 1.4401
Z08 Vent-/drain valve 1/2" NPT / material PTFE
Z09 Vent-/drain valve 1/2" NPT / material PP
Z10 Vent-/drain valve 1/2" NPT / material PVDF
Z11 Vent-/drain ball valve 1/2" NPT / material 1.4401
Z12 Vent-/drain valve 1/2" NPT, einseitig geflanscht mit DN 15 PN 16
Z13 Vent-/drain valve 1/2" NPT / material: 1.4401
Insulation
Low-temperature-insulation Armaflex -75...+105 °C (only available with Aluminium-
Z14
indication rail and Titanium float) (each 100 mm)
Z15 Low-temperature-insulation with mineral wool with 316SS arming (each 100 mm)
Heat insulation ceramic tape; op. temperature up to 600 °C (only available with
Z16
Aluminium-indication rail and Titanium float) (each 100 mm)
Insulation guide plate*, material 1.4404; height = 80 mm Equipment for Armaflex- or
Z17
ceramic insulation (each 100 mm)
Z18 Makrolon window for insulation (each 100 mm)

218
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


Special equipment & Accessories

Order Codes for Electronic Accessories and Switches

Code Description
Painting
Z19 Device completely painted with RAL-colour (grounding + main paint)
Aluminium grey RAL 9007 (80°C)
Z20
with Hempel's Silicone Aluminium 56910 (600°C)
ZPY other paintings
Security Springs
Z21 spring at top of gauge
Z22 spring at bottom of gauge

219
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


Special designs

Ordering Codes for Special designs

Code Description
ITA-3 BV Bureau Veritas
ITA-6 BV Bureau Veritas
ITA-3 GL Design for maritime and inland navigation acc. rules of "German Lloyd"
(Individual Acceptance Test)
ITA-6 GL Design for maritime and inland navigation acc. rules of "German Lloyd"
(Individual Acceptance Test)
ITA-3 LR Lloyd's Register
ITA-6 LR Lloyd's Register
ITA-6 D Design as steam regulator acc. TRD incl. 2 switches type: LMS-AH
ITA-7-D Design as steam regulator acc. TRD incl. 2 switches type: LMS-AH
ITA-3 / 3.0 Ex
ITA-4 /4.0 Ex Design for Ex-zone 0 (following 94/9/EG: II 1 Gc IIC T1...T6)
ITA-4.1 / 4.1.0 Ex
ITA-5 / 5.0 Ex According to the "Statement of application for directive 94/9/EC", issued by
"TÜV Industrie Service GmbH" (notified body), the directive 94/9/EC is
ITA-6 / 6.0 Ex
not applicable for ITA mag. level gauges, as they have no ignition sources
ITA-7 / 7.0 Ex of their own. So the level gauge can be used in Ex-zone 0 without being
ITA-10 / 10.0 Ex certified, once the technical specifications described in the statement have
ITA-11 / 11.0 Ex have been followed.
ITA-12 / 12.0 Ex

220
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


Spare Parts

Order codes for mag. Level Gauges type: ITA

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
Floats for ITA-3 and ITA-3.0 (PN16/150 lbs)
3V0100K1 16 316SS 52 125 1,4907 N
3V0100K3 16 316SS 52 125 1,0524 N only with 316SS or Aluminium indication rail
3V0120K1 16 316SS 52 145 1,2346 N
3V0120K3 16 316SS 52 145 0,9034 N only with 316SS or Aluminium indication rail
3V0150K1 16 316SS 52 175 0,9905 N
3V0150K3 16 316SS 52 175 0,8606 N only with 316SS or Aluminium indication rail
3V0180K1 16 316SS 52 205 0,8781 N
3V0180K3 16 316SS 52 205 0,7022 N only with 316SS or Aluminium indication rail
3V0240K1 16 316SS 52 265 0,7374 N
3V0240K3 16 316SS 52 265 0,6209 N only with 316SS or Aluminium indication rail
3V1240K1 40 316SS 52 265 1,000 N
3T0100K1 16 Titanium 50,8 125 1,1788 N do not use with hydrogen or alcohol compounds
3T0100K3 16 Titanium 50,8 125 0,7821 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0120K1 16 Titanium 50,8 145 0,9646 N do not use with hydrogen or alcohol compounds
3T0120K3 16 Titanium 50,8 145 0,6514 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0150K1 16 Titanium 50,8 175 0,7763 N do not use with hydrogen or alcohol compounds
3T0150K3 16 Titanium 50,8 175 0,5675 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0180K1 16 Titanium 50,8 205 0,6716 N do not use with hydrogen or alcohol compounds
3T0180K3 16 Titanium 50,8 205 0,5094 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0240K1 16 Titanium 50,8 265 0,5723 N do not use with hydrogen or alcohol compounds
3T0240K3 16 Titanium 50,8 265 0,4550 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0300K1 16 Titanium 50,8 325 0,4955 N do not use with hydrogen or alcohol compounds
3T0300K3 16 Titanium 50,8 325 0,4063 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0400K1 16 Titanium 50,8 425 0,4358 N do not use with hydrogen or alcohol compounds
3T0400K3 16 Titanium 50,8 425 0,3719 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0500K1 16 Titanium 50,8 525 0,4017 N do not use with hydrogen or alcohol compounds
3T0500K3 16 Titanium 50,8 525 0,3539 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3T0600K1 16 Titanium 50,8 625 0,3761 N do not use with hydrogen or alcohol compounds
3T0600K3 16 Titanium 50,8 625 0,3371 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
3H0150K1 16 Titanium, 52 175 0,9020 N
Halar-coated
3HC012K1 16 Hastelloy C4 52 175 1,2455 N
3HC024K1 16 Hastelloy C4 52 265 0,7510 N
3HC024K3 16 Hastelloy C4 52 265 0,6296 N only with 316SS or Aluminium indication rail
Floats for ITA-3 Cryo (PN16/150 lbs, for cryogenic applications)
3C0240K1 16 Titanium 50,8 265 0,5723 N without spacers;
do not use for hydrogen or alcohol compounds
3C0500K1 16 Titanium 45 525 0,5509 N with spacers;
do not use for hydrogen or alcohol compounds
3C0500K3 16 Titanium 45 525 0,5038 N with spacers;
only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds

221
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


Spare Parts

Order codes for mag. Level Gauges type: ITA

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
Floats for ITA-3-CR64 and ITA-3.0-CR64 (PN16/150 lbs, for cryogenic applications)
3C0501K1 16 Titanium 50,8 525 0,4017 N with spacers;
do not use for hydrogen or alcohol compounds
3C0501K2 16 Titanium 50,8 525 0,3890 N with spacers;
do not use for hydrogen or alcohol compounds
Floats for ITA-3.5 (PN16/150 lbs, wetted parts E-CTFE (Halar)-coated)
35H024K1 16 Titanium, 52 240 0,6873 N
Halar-coated
35H024K3 16 Titanium, 52 240 0,5645 N only with 316SS or Aluminium indication rail
Halar-coated
Floats for ITA-3.8 (PN16/150 lbs, wetted parts E-CTFE (Halar)-coated, applicable for vacuum-service)
34PVD1K1 10 E-TFE 50 135 1,3000 N
34PVD2K1 10 E-TFE 50 255 0,8500 N
34GLA2K2 10 Borosilicate 50 255 0,8500 N
Floats for ITA-4 and ITA-4.0 (PN16/150 lbs, top-of tank mounting)
[max. Rod length: A = 500 mm; B = 750 mm; C = 1000 mm; D = 1250 mm; E = 1500 mm; F = 1750 mm; H = 2000]
4V0240R1A 16 316L 52,0 265 0,9500 N
4V0240R1B 16 316L 52,0 265 1,0000 N
4T0240R1A 16 Titanium 50,8 265 0,6890 N do not use with hydrogen or alcohol compounds
4T0240R1B 16 Titanium 50,8 265 0,7250 N do not use with hydrogen or alcohol compounds
4T0240R1C 16 Titanium 50,8 265 0,7610 N do not use with hydrogen or alcohol compounds
4T0240R1D 16 Titanium 50,8 265 0,7970 N do not use with hydrogen or alcohol compounds
4T0240R1E 16 Titanium 50,8 265 0,8330 N do not use with hydrogen or alcohol compounds
4T0240R1F 16 Titanium 50,8 265 0,8690 N do not use with hydrogen or alcohol compounds
4T0240R1H 16 Titanium 50,8 265 0,9050 N do not use with hydrogen or alcohol compounds
4T0240K2A 16 Titanium 50,8 265 0,6480 N do not use with hydrogen or alcohol compounds
4T0240K2B 16 Titanium 50,8 265 0,6840 N do not use with hydrogen or alcohol compounds
4T0240K2C 16 Titanium 50,8 265 0,7200 N do not use with hydrogen or alcohol compounds
4T0240K2D 16 Titanium 50,8 265 0,7560 N do not use with hydrogen or alcohol compounds
4T0240K2E 16 Titanium 50,8 265 0,7920 N do not use with hydrogen or alcohol compounds
4T0240K2F 16 Titanium 50,8 265 0,8280 N do not use with hydrogen or alcohol compounds
4T0240K2H 16 Titanium 50,8 265 0,8640 N do not use with hydrogen or alcohol compounds
4T0240K3A 16 Titanium 50,8 265 0,5820 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3B 16 Titanium 50,8 265 0,6810 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3C 16 Titanium 50,8 265 0,6540 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3D 16 Titanium 50,8 265 0,6900 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3E 16 Titanium 50,8 265 0,7260 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3F 16 Titanium 50,8 265 0,7620 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0240K3H 16 Titanium 50,8 265 0,7980 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300R1A 16 Titanium 50,8 325 0,6010 N do not use with hydrogen or alcohol compounds
4T0300R1B 16 Titanium 50,8 325 0,6290 N do not use with hydrogen or alcohol compounds
4T0300R1C 16 Titanium 50,8 325 0,6580 N do not use with hydrogen or alcohol compounds
4T0300R1D 16 Titanium 50,8 325 0,6870 N do not use with hydrogen or alcohol compounds
4T0300R1E 16 Titanium 50,8 325 0,7160 N do not use with hydrogen or alcohol compounds
4T0300R1F 16 Titanium 50,8 325 0,7450 N do not use with hydrogen or alcohol compounds
4T0300R1H 16 Titanium 50,8 325 0,7730 N do not use with hydrogen or alcohol compounds

222
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


Spare Parts

Order codes for mag. Level Gauges type: ITA

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
Floats for ITA-4 and ITA-4.0 (PN16/150 lbs, top-of tank mounting) (Continuation)
[max. Rod length: A = 500 mm; B = 750 mm; C = 1000 mm; D = 1250 mm; E = 1500 mm; F = 1750 mm; H = 2000]
4T0300K2A 16 Titanium 50,8 325 0,5680 N do not use with hydrogen or alcohol compounds
4T0300K2B 16 Titanium 50,8 325 0,5970 N do not use with hydrogen or alcohol compounds
4T0300K2C 16 Titanium 50,8 325 0,6250 N do not use with hydrogen or alcohol compounds
4T0300K2D 16 Titanium 50,8 325 0,6540 N do not use with hydrogen or alcohol compounds
4T0300K2E 16 Titanium 50,8 325 0,6830 N do not use with hydrogen or alcohol compounds
4T0300K2F 16 Titanium 50,8 325 0,7120 N do not use with hydrogen or alcohol compounds
4T0300K2H 16 Titanium 50,8 325 0,7410 N do not use with hydrogen or alcohol compounds
4T0300K3A 16 Titanium 50,8 325 0,5120 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3B 16 Titanium 50,8 325 0,5410 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3C 16 Titanium 50,8 325 0,5690 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3D 16 Titanium 50,8 325 0,5980 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3E 16 Titanium 50,8 325 0,6270 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3F 16 Titanium 50,8 325 0,6560 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0300K3H 16 Titanium 50,8 325 0,6850 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
Floats for ITA-4.1 and ITA-4.1.0 (atm., top-of tank mounting)
[max. Rod length: A = 500 mm; B = 750 mm; C = 1000 mm; D = 1250 mm; E = 1500 mm; F = 1750 mm; H = 2000]
4T0152R1A ATM Titanium 80 175 0,4070 N do not use with hydrogen or alcohol compounds
4T0152R1B ATM Titanium 80 175 0,4310 N do not use with hydrogen or alcohol compounds
4T0152R1C ATM Titanium 80 175 0,4540 N do not use with hydrogen or alcohol compounds
4T0152R1D ATM Titanium 80 175 0,4770 N do not use with hydrogen or alcohol compounds
4T0152R1E ATM Titanium 80 175 0,5000 N do not use with hydrogen or alcohol compounds
4T0152R1F ATM Titanium 80 175 0,5240 N do not use with hydrogen or alcohol compounds
4T0152R1H ATM Titanium 80 175 0,5470 N do not use with hydrogen or alcohol compounds
4T0152K2A ATM Titanium 80 175 0,4700 N do not use with hydrogen or alcohol compounds
4T0152K2B ATM Titanium 80 175 0,4310 N do not use with hydrogen or alcohol compounds
4T0152K2C ATM Titanium 80 175 0,4540 N do not use with hydrogen or alcohol compounds
4T0152K2D ATM Titanium 80 175 0,4770 N do not use with hydrogen or alcohol compounds
4T0152K2E ATM Titanium 80 175 0,5000 N do not use with hydrogen or alcohol compounds
4T0152K2F ATM Titanium 80 175 0,5240 N do not use with hydrogen or alcohol compounds
4T0152K2H ATM Titanium 80 175 0,5470 N do not use with hydrogen or alcohol compounds
4T0152K3A ATM Titanium 80 175 0,4710 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3B ATM Titanium 80 175 0,4940 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3C ATM Titanium 80 175 0,5180 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3D ATM Titanium 80 175 0,5410 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3E ATM Titanium 80 175 0,5640 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3F ATM Titanium 80 175 0,6870 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0152K3H ATM Titanium 80 175 0,6100 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds

223
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


Spare Parts

Order codes for mag. Level Gauges type: ITA

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
Floats for ITA-4.1 and ITA-4.1.0 (atm., top-of tank mounting) / Continuation
[max. Rod length: A = 500 mm; B = 750 mm; C = 1000 mm; D = 1250 mm; E = 1500 mm; F = 1750 mm; H = 2000]
4T0182R1A ATM Titanium 80 205 0,3620 N do not use with hydrogen or alcohol compounds
4T0182R1B ATM Titanium 80 205 0,3810 N do not use with hydrogen or alcohol compounds
4T0182R1C ATM Titanium 80 205 0,4000 N do not use with hydrogen or alcohol compounds
4T0182R1D ATM Titanium 80 205 0,4200 N do not use with hydrogen or alcohol compounds
4T0182R1E ATM Titanium 80 205 0,4390 N do not use with hydrogen or alcohol compounds
4T0182R1F ATM Titanium 80 205 0,4580 N do not use with hydrogen or alcohol compounds
4T0182R1H ATM Titanium 80 205 0,4780 N do not use with hydrogen or alcohol compounds
4T0182K2A ATM Titanium 80 205 0,3370 N do not use with hydrogen or alcohol compounds
4T0182K2B ATM Titanium 80 205 0,3570 N do not use with hydrogen or alcohol compounds
4T0182K2C ATM Titanium 80 205 0,3760 N do not use with hydrogen or alcohol compounds
4T0182K2D ATM Titanium 80 205 0,3950 N do not use with hydrogen or alcohol compounds
4T0182K2E ATM Titanium 80 205 0,4150 N do not use with hydrogen or alcohol compounds
4T0182K2F ATM Titanium 80 205 0,3430 N do not use with hydrogen or alcohol compounds
4T0182K2H ATM Titanium 80 205 0,4530 N do not use with hydrogen or alcohol compounds
4T0182K3A ATM Titanium 80 205 0,3000 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3B ATM Titanium 80 205 0,3190 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3C ATM Titanium 80 205 0,3380 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3D ATM Titanium 80 205 0,3580 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3E ATM Titanium 80 205 0,3770 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3F ATM Titanium 80 205 0,3960 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0182K3H ATM Titanium 80 205 0,4160 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242R1A ATM Titanium 80 265 0,2980 N do not use with hydrogen or alcohol compounds
4T0242R1B ATM Titanium 80 265 0,3120 N do not use with hydrogen or alcohol compounds
4T0242R1C ATM Titanium 80 265 0,3270 N do not use with hydrogen or alcohol compounds
4T0242R1D ATM Titanium 80 265 0,3410 N do not use with hydrogen or alcohol compounds
4T0242R1E ATM Titanium 80 265 0,3560 N do not use with hydrogen or alcohol compounds
4T0242R1F ATM Titanium 80 265 0,3700 N do not use with hydrogen or alcohol compounds
4T0242R1H ATM Titanium 80 265 0,3850 N do not use with hydrogen or alcohol compounds
4T0242K2A ATM Titanium 80 265 0,2800 N do not use with hydrogen or alcohol compounds
4T0242K2B ATM Titanium 80 265 0,2940 N do not use with hydrogen or alcohol compounds
4T0242K2C ATM Titanium 80 265 0,3090 N do not use with hydrogen or alcohol compounds
4T0242K2D ATM Titanium 80 265 0,3230 N do not use with hydrogen or alcohol compounds
4T0242K2E ATM Titanium 80 265 0,3880 N do not use with hydrogen or alcohol compounds
4T0242K2F ATM Titanium 80 265 0,3520 N do not use with hydrogen or alcohol compounds
4T0242K2H ATM Titanium 80 265 0,3670 N do not use with hydrogen or alcohol compounds
4T0242K3A ATM Titanium 80 265 0,2530 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3B ATM Titanium 80 265 0,2680 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3C ATM Titanium 80 265 0,2820 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3D ATM Titanium 80 265 0,2970 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3E ATM Titanium 80 265 0,3110 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3F ATM Titanium 80 265 0,3260 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds
4T0242K3H ATM Titanium 80 265 0,3400 N only with 316SS or Aluminium indication rail;
do not use with hydrogen or alcohol compounds

224
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


Spare Parts

Order codes for mag. Level Gauges type: ITA

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
Floats for ITA-5 (top-bottom connection)
Please see ITA-3 to ITA-13
Floats for ITA-6 and ITA-6.0 (PN40/300 lbs)
6V0100K1 30 316L 52 125 1,5188 N
6V0100K3 30 316L 52 125 1,0891 N only with 316SS or Aluminium indication rail
6V0120K1 30 316L 52 145 1,2780 N
6V0120K3 30 316L 52 145 0,9519 N only with 316SS or Aluminium indication rail
6V0150K1 30 316L 52 175 1,0711 N
6V0150K3 30 316L 52 175 0,8309 N only with 316SS or Aluminium indication rail
6V0180K1 30 316L 52 205 0,9486 N
6V0180K3 30 316L 52 205 0,8140 N only with 316SS or Aluminium indication rail
6V0240K1 30 316L 52 265 0,7738 N
6V0240K3 30 316L 52 265 0,6513 N only with 316SS or Aluminium indication rail
6T0100K1 40 Titanium 50,8 125 1,3114 N do not use with hydrogen or alcohol compounds
6T0100K3 40 Titanium 50,8 125 0,8975 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
6T0120K1 40 Titanium 50,8 145 1,1007 N do not use with hydrogen or alcohol compounds
6T0120K3 40 Titanium 50,8 145 0,7837 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
6T0150K1 40 Titanium 50,8 175 0,9029 N do not use with hydrogen or alcohol compounds
6T0150K3 40 Titanium 50,8 175 0,6763 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
6T0180K1 40 Titanium 50,8 205 0,7791 N do not use with hydrogen or alcohol compounds
6T0180K3 40 Titanium 50,8 205 0,6100 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
6T0240K1 40 Titanium 50,8 265 0,6391 N do not use with hydrogen or alcohol compounds
6T0240K3 40 Titanium 50,8 265 0,5187 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
6T0300K1 40 Titanium 50,8 325 0,5694 N do not use with hydrogen or alcohol compounds
6T0300K3 40 Titanium 50,8 325 0,4812 N do not use with hydrogen or alcohol compounds
6T0400K1 40 Titanium 50,8 425 0,5300 N do not use with hydrogen or alcohol compounds
6T0400K3 40 Titanium 50,8 425 0,4373 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
6T0500K1 40 Titanium 50,8 525 0,4463 N do not use with hydrogen or alcohol compounds
6T0500K3 40 Titanium 50,8 525 0,4098 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
6T0600K1 40 Titanium 50,8 625 0,4370 N do not use with hydrogen or alcohol compounds
6T0600K3 40 Titanium 50,8 625 0,3834 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
6H0200K1 40 Titanium, 52 265 0,7674 N
Halar-coated
6H0200K3 40 Titanium, 52 265 0,6470 N only with 316SS or Aluminium indication rail
Halar-coated
6HC012K1 40 Hastelloy C4 52 145 1,2400 N
6HC024K1 40 Hastelloy C4 52 265 0,7470 N
6HC024K3 40 Hastelloy C4 52 265 0,6600 N only with 316SS or Aluminium indication rail
Floats for ITA-6 Cryo and ITA-6.0 Cryo (PN40/300 lbs; cryogenic applications)
6C0240K1 40 Titanium 50,8 265 0,6391 N without spacers
do not use with hydrogen or alcohol compounds
6C0500K1 40 Titanium 45 525 0,5981 N with spacers
do not use with hydrogen or alcohol compounds
6HC024K3 24 Hastelloy C4 52 265 0,66 N with spacers, only with Aluminium or SS indication rail
Floats for ITA-6-CR64 and ITA-6.0-CR64 (PN40/300 lbs; cryogenic applications)
6C0240K1 40 Titanium 50,8 265 0,6391 N with spacers
do not use with hydrogen or alcohol compounds
6C0501K1 40 Titanium 45 525 0,5981 N with spacers, only with Aluminium or SS indication rail
do not use with hydrogen or alcohol compounds

225
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


Spare Parts

Order codes for mag. Level Gauges type: ITA

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
Floats for ITA-7 and ITA-7.0 (PN64/300 lbs)
7T0240K1 64 Titanium 50,8 265 0,6820 N do not use with hydrogen or alcohol compounds
7T0240K3 64 Titanium 50,8 265 0,5551 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
7T0300K1 64 Titanium 50,8 325 0,6064 N do not use with hydrogen or alcohol compounds
7T0300K3 64 Titanium 50,8 325 0,5168 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
7T0500K3 64 Titanium 50,8 525 0,4450 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
7T0600K3 64 Titanium 50,8 625 0,4243 N only with 316SS or Aluminium indication rail
do not use with hydrogen or alcohol compounds
Floats for ITA-8.1 (PN6; PVC)
8PVC01K1 10 PVC 50 135 1,1500 N only with 316SS or Aluminium indication rail
8PVC02K1 10 PVC 50 255 0,7500 N only with 316SS or Aluminium indication rail
Floats for ITA-8.2 (PN6; PP)
8PVC01K1 10 PP 50 135 0,9500 N only with 316SS or Aluminium indication rail
8PVC02K1 10 PP 50 255 0,6500 N only with 316SS or Aluminium indication rail
Floats for ITA-8.3 (PN6; PVDF)
8PVC01K1 10 PVDF 50 135 1,3000 N only with 316SS or Aluminium indication rail
8PVC02K1 10 PVDF 50 255 0,8500 N only with 316SS or Aluminium indication rail
Floats for ITA-9.1 (PN6; PVC; mounted from top of tank)
9PVC03K1 6 PVC 50 135 N only with 316SS or Aluminium indication rail
Floats for ITA-9.2 (PN6; PP; mounted from top of tank)
9PP030K1 6 PP 50 N only with 316SS or Aluminium indication rail
Floats for ITA-9.3 (PN6; PVDF; mounted from top of tank)
9PVD03K1 6 PP 50 N only with 316SS or Aluminium indication rail
Floats for ITA-10 and ITA-10.0 (PN100/600 lbs)
10V324K3 100 316L 52 265 0,6122 Y only with 316SS or Aluminium indication rail
10T024K1 80 Titanium 50,8 265 0,7011 N do not use for hydrogen or alcohol compounds
10T024K3 80 Titanium 50,8 265 0,5823 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T030K1 80 Titanium 50,8 325 0,6212 N do not use for hydrogen or alcohol compounds
10T030K3 80 Titanium 50,8 325 0,5275 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T040K1 80 Titanium 50,8 425 0,5515 N do not use for hydrogen or alcohol compounds
10T040K3 80 Titanium 50,8 425 0,4871 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T050K1 80 Titanium 50,8 525 0,5095 N do not use for hydrogen or alcohol compounds
10T050K3 80 Titanium 50,8 525 0,4574 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T060K1 80 Titanium 50,8 625 0,4632 N do not use for hydrogen or alcohol compounds
10T060K3 80 Titanium 50,8 625 0,4209 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T124K1 100 Titanium 50,8 265 0,8299 N do not use for hydrogen or alcohol compounds
10T124K3 100 Titanium 50,8 265 0,7006 N only with 316SS or Aluminium indication rail;
Float for high-temperature applications;
do not use for hydrogen or alcohol compounds
10T130K1 100 Titanium 50,8 325 0,7617 N do not use for hydrogen or alcohol compounds
10T130K3 100 Titanium 50,8 325 0,6594 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T140K1 100 Titanium 50,8 425 0,6779 N do not use for hydrogen or alcohol compounds
10T140K3 100 Titanium 50,8 425 0,6075 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
10T150K1 100 Titanium 50,8 525 0,6321 N do not use for hydrogen or alcohol compounds
10T150K3 100 Titanium 50,8 525 0,5775 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds

226
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


Spare Parts

Order codes for mag. Level Gauges type: ITA

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
Floats for ITA-11 and ITA-11.0 (PN160/1500 lbs)
11V324K2 160 316L 46 265 0,7736 Y
11T330K2 160 Titanium 46 325 0,4901 Y do not use for hydrogen or alcohol compounds
11T018K1 130 Titanium 45 205 1,0185 N do not use for hydrogen or alcohol compounds
11T018K3 130 Titanium 45 205 0,8455 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T024K1 130 Titanium 45 265 0,8600 N do not use for hydrogen or alcohol compounds
11T024K3 130 Titanium 45 265 0,7450 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T030K1 130 Titanium 45 325 0,7822 N do not use for hydrogen or alcohol compounds
11T030K3 130 Titanium 45 325 0,6949 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T040K1 130 Titanium 45 425 0,7028 N do not use for hydrogen or alcohol compounds
11T040K3 130 Titanium 45 425 0,6391 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T050K1 130 Titanium 45 525 0,6587 N do not use for hydrogen or alcohol compounds
11T050K3 150 Titanium 45 525 0,6106 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T124K3 150 Titanium 46 265 0,7324 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T130K3 150 Titanium 46 325 0,7042 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T140K3 150 Titanium 46 425 0,6164 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T150K3 150 Titanium 46 525 0,6008 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T218K1 160 Titanium 42 205 1,1692 N do not use for hydrogen or alcohol compounds
11T218K3 160 Titanium 42 205 0,9291 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T224K1 160 Titanium 42 265 0,9768 N do not use for hydrogen or alcohol compounds
11T224K3 160 Titanium 42 265 0,8120 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T230K1 160 Titanium 42 325 0,8871 N do not use for hydrogen or alcohol compounds
11T230K3 160 Titanium 42 325 0,7613 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T240K1 160 Titanium 42 425 0,7832 N do not use for hydrogen or alcohol compounds
11T240K3 160 Titanium 42 425 0,6934 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
11T250K1 160 Titanium 42 525 0,7268 N do not use for hydrogen or alcohol compounds
11T250K3 160 Titanium 42 525 0,6571 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
Floats for ITA-12 and ITA-12.0 (PN250/1500 lbs)
12V324K3 250 316L 46 265 0,7736 Y
12T324K3 250 Titanium 46 265 0,5526 Y only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T218K1 250 Titanium 42 205 1,2085 N do not use for hydrogen or alcohol compounds
12T218K3 250 Titanium 42 205 0,9659 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T224K1 250 Titanium 42 265 1,0396 N do not use for hydrogen or alcohol compounds
12T224K3 250 Titanium 42 265 0,9659 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T230K1 250 Titanium 42 325 0,9250 N do not use for hydrogen or alcohol compounds
12T230K3 250 Titanium 42 325 0,7978 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T240K1 250 Titanium 42 425 0,8304 N do not use for hydrogen or alcohol compounds
12T240K3 250 Titanium 42 425 0,7394 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds

227
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


Spare Parts

Order codes for mag. Level Gauges type: ITA

Description
Floats
Code Pressure Material Diameter Length min. vented Notes
[bar] [mm] [mm] Density [Y/N]
[kg/dm³]
Floats for ITA-12 and ITA-12.0 (PN250/1500 lbs) (Continuation)
12T124K3 250 Titanium 38 265 0,8944 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T130K3 250 Titanium 38 325 0,8281 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
12T250K1 250 Titanium 42 525 0,7763 N do not use for hydrogen or alcohol compounds
12T250K3 250 Titanium 42 525 0,7055 N only with 316SS or Aluminium indication rail;
do not use for hydrogen or alcohol compounds
Floats for ITA-13 and ITA-13.0 (PN320/2500 lbs)
13V330K3 320 316L 38 325 0,7269 Y only with 316SS or Aluminium indication rail
13T324K3 320 Titanium 38 265 0,5366 Y only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds
13T024K3 320 Titanium 38 265 0,8985 N only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds
13T330K3 320 Titanium 38 325 0,5032 Y only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds
13T040K3 320 Titanium 38 425 0,7582 N only with 316SS or Aluminium indication rail;
do not use for hydrogen and alcohol compounds

228
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

mag. level gauges


type: ITA
Spare parts

Order codes for Spare Parts

Code Description Material


E01 Indication Rail, max. oper. temp. 100 °C Markolon
E02 Indication Rail, max. oper. temp. 400 °C Aluminium
E03 Indication Rail, max. oper. temp. 400 °C 1.4301
E04 Gasket for ITA-3…ITA-7, max oper. temp. 100 °C PTFE
E05 Gasket for ITA-3…ITA-7, max oper. temp. 400 °C Klingersil
E06 Spiral wound or comb profiled gasket for ITA7…ITA11, 1.4571
max oper. Temp. 400 °C
E07 spiral wound or comb profiled gasket for ITA12…ITA13, 1.4571
max oper. Temp. 400 °C
E08 Gaskets for all mag. level gauges made from plastics Viton
E09 Clamp for indication rails VA
E10 Gaskets for vent-/drain plug R1/2" Copper
E11 PTFE
E12 Soft Iron

More Spare parts, as well as special floats on request.

229
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


Inspection, Testing, Documentation

General Documentation

Code Description
D001 Certificate of Conformity
D003 Drawings for special types
D004 Certificate of origin
D005 Certificate of orign by German Chamber of Commerce
D006 Legalised by Embassy of recipient
D007 Standard QA-Plan
D008 Inspection certificate
D009 QA-Manual
D009a Calibration certificate
D009b Legalised by Embassy of recipient
Documents on CD
D009c only one manual or technical information
D009d up to 4 manuals or technical information
D009e manuals incl. e.g. 3.1B, drawings, cert. of conf. etc.
D009f add. documents as paper print

Orderwise Documentation

Code Description
D010 Production schedule
D011 Manufacturing Progress Status Report
D012 Test Procedures (Covering Manufacturing)
D013 Welding Procedures (WPS, PQR),
D014 Welding Procedures (WPS, PQR),
S i l i l

230
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


Inspection, Testing, Documentation

Material certificates

Code Description
D015 Material Certificate EN 10204:2004-2.2
D016 Material certificates acc. EN 10204:2004-3.1, for ITA-3 to ITA-6, please
advise if cast marking for pressure retaining parts required
Cast marking of pressure retaining parts
D016a for special material (ITA3 to ITA-6)
Cast marking of pressure retaining parts
D017 Material certificates acc. EN 10204:2004-3.1, for ITA-7 to ITA-13,
please advise if cast marking for pressure retaining parts required
Cast marking of pressure retaining parts
D017a for special material (ITA7 to ITA-13)
Cast marking of pressure retaining parts
D018 Material certificates acc. EN 10204:2004-3.2 (former 3.1C or 3.1A)

CE Declaration of conformity acc. PED 97/23/EG

Code Description
D019 Category sound engineering paractice manufactured and tested acc. Module A1,
checked against diagram 1of PED 97/23/EG
D020 Category I,II und III manufactured and tested acc. Module H, checked against diagram
1of PED 97/23/EG
D022 Category IV manufactured and tested acc. Modul G. Layout test and inspection by
German TÜV

Inspection and Testing

Code Description
D023 Hydr. pressure test incl. test certificate
D024 Inspection And Pressure Testing acc. AD-Merkblatt, TRB and TRD By
German TÜV, incl. Cast Marking and Certificates EN 10204 3.1B, for
Standard ITA
D025 Inspection And Pressure Testing acc. AD-Merkblatt, TRB and TRD By
German TÜV, incl. Cast Marking and Certificates EN 10204 3.1B, for
Special Constructed ITA
D026 Radiographic Examination Of Welds (Only Buttwelds) acc. DIN 54111

D026.1 Radiographic Examination Of Welds (Only Buttwelds) acc. ASME


Sec. VIII

231
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Mag. Level Gauge


Inspection, Testing, Documentation

Inspection and Testing (Continuation)

Code Description
D027 Dyepenetrant Examination Of Welds acc.
EN473:2000 and PED

D027.1 Dyepenetrant Examination Of Welds acc.


ASME Sec. VIII

D028 Härteprüfung nach NACE MR01-75, incl. NACE-


D029 Weight Certificate (for all units of an order)
D030 PMI-Check
D031 Percentage of ferrite in welding

D032 Endoscopy (Weldings inside) + Photo/Video

Certificates for electronic equipment

Code Description
D032 Standard wiring plans and data sheets
D033 ATEX-certificates

General notes:

The standard documentation mentioned in our quotations and order


acknowledgements consists of:
1 off installation & operation manual (hard copy)

232
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

5. Special Constructions

5.1 ITA-T1S Continuous level sensing element

Technical Information / ITA-T1S special features

x Simple and rugged design


x UHOLDEOHSHUIRUPDQFHLQOLTXLGVZLWKGHQVLWLHVRI•NJGPñ
x VKRUWPRXQWLQJGHSWK•PP  
therefore suitable for small vessels.
x indicating length up to 3000 mm (118")
x resistant to pressures of d 40 bar (580 psi g) and
temperatures of d 300 °F (266 °F)
x housing: casst aluminium or stainless steel in
IP65, equivalent to NEMA 4 and NEMA 4X
enclosure
x wide variety of material combinations
x various plastic coatings availabel for all wetted parts
x 4…20 mA or Hart protocol 4…20 mA output via the
signal amplifier

Introduction

Intra-Automation does not limit you with the standard designs


catalogued here. Our experienced engineering staff, with extensive
research and development capabilities, will customize liquid level
indicators to meet your specific requirements. Modifications regarding
the variety of mountings, exotic materials and float configurations
provide compatibility for most liquid media, various tank temperatures
and pressures, as well as liquids with a broad range of specific
gravities.

Operation Fig 1: ITA-T1S with Eexd housing


The ITA-T1S Liquid Level Transmitters, vertically mounted in the tank and tank mounting flange

and cable connected (3-wire) to a remote receiver, operates on the


float principle.
A float guided on a non-magnetic tube follows the level of the liquid
surface, thereby actuating the reed switches located inside the tube
by means of a built-in magnet system. The reed switches shunt over
parts of a resistor string.
The magnet system operates the reed switches according to the
position of the float and thus causes the : resistance of the resistor
string to change as a function for liquid level.
A current 4...20 mA is then obtained as an output signal together with
the INT5333; INT5333ATEX; TMT182 signal conditioner. The float travel
distance can be limited by stops fitted to the guide tube.

Fig 2 diagammatic view of reed

Monitoring switches

Combined with DigiFlow 520 these transmitters form a complete liquid


level monitoring system. Used as a separate system with a process
control system, Intra transmitters can interface with programmable controllers and
other industrial microprocessors.

Fig 3 Digiflow 520

233
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Interface Measuring

Very often dissimilar liquids resides in a tank. Most tank gauging methods
are limited in these cases and only indicate the level of the uppermost
surface. But, with using Intra-Automation level sensing elements, you can
easily monitor the interface between liquids. By adjusting the specific
gravity of the magnet float, Intra can adapt the transmitter to monitor the
interface of a broad range of media. This principle applies to oil and water,
slurries, acid, bilge and other dissimilar liquids.
In conjunction with DigiFlow 520 tank level, ITA-T1S will help assure that
only the “correct” liquid is taken from a tank, or introduced into a process
system.

Technical data Fig 4 Interface level measurement

Level Transmitter ITA-T1S


overall length 0,3…6 m (0.98…19.69 ft)
measurement accuracy ± 5, 10 or 20 mm (± 0.2", 0.39" or 0.79")
ambient temperature
x aluminium housing -40…+60 °C (-40…+140 °F)
x stainless steel housing -40…+60 °C (-40…+140 °F)
tank product
x temperature -10…+100 °C (-14…+212 °F)
x min. density 0,5 kg/dm³ (32.21 lbs/ft³)
x max. allowable op. pressure 40 bar (580 psi g)
protection category DIN 40050/IEC144 IP65 (NEMA 4, NEMA 4X)
terminals
cable entry
x aluminium housing PG16 (optional M20x1.5)
x stainless steel housing PG13,5 (optional M20x1.5)
other entries on request
current output connection
x screw connection acc. ISO R 1/2"
x screw connection acc. ANSI/NEMA 1/2" NPT
x flanges acc. DIN DN50, DN100, PN16 and PN40
x flanges acc. ANSI 2", 4" class 150 lbs/RF or 300 lbs/RF
other connections on request
materials
housing
x standard cast aluminium (option: with epoxy finish)
x special stainless steel
x explosion proof cast aluminium with epoxy finish
flange carbon steel, stainless steel, (optional Halar-coated),
PP, PVC, PVDF
thread stainless steel
guide tube carbon steel, stainless steel, (optional Halar-coated),
PP, PVC, PVDF
float see "float type"

234
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Float type

1) shape dimensions in material min. density max. op. max. liquid


type
mm (inches) kg/dm³ Pressure in temperature
(lbs/ft³ bar (psi g) in °C (°F)
@ 20 °C (38 °F)
A spherical ‡ 52 1.4571 0,7 40 -40…+100
(2.05) (316Ti) (43.70) (580) (-40…+266)
B spherical ‡ 80 3.7035 0,6 17 -40…+100
(3.15) (Titanium) (37.46) (247) (-40…+266)
C cylindrical ‡ 80x35 1.4571 0,5 13 -40…+100
(3.15x1.38) (316Ti) (31.21) (189) (-40…+266)
D cylindrical ‡ 44x52 1.4571 0,8 25 -40…+100
(316Ti) (49.94) (362) (-40…+266)
E cylindrical ‡ 32x34 Buna N 0,55 10 0…+82
(150) (-18…+180)
F cylindrical ‡ 32x34 Intox 0,5 100 -40…+100
(1450) (-40…+266)
1) other types on request

Float type A Float type B Float type C

Float type D Float type E Float type F

Transmitter

Type Output Supply Current Operating Min./max. Approval


in mA voltage in mA temperature resistance
in VDC in °C (°F) in Ohm

INT5333 4…20 8…28 4…20 -20…+85 50 non


(-4…+185) 6000
TMT182 4…20 10…30 4…20 -40…+85 0…400 EEx ia C
0…2000 FM IS
CSA IS
TMT184 Profibus 10…35 Profibus -40…+85 10…400 EEx ia CII
10…2000 ATEX
FM
CSA

235
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Order key:

ITA-T1S Continuous Level Sensing Element


Material of guide tube
S 316Ti (1.4571)
T Titanium
P Polypropylene
Y others
Material of tank connection
S 316Ti (1.4571)
T Carbon steel
Y others
Type/size of tank connedtion
R1 R1/2"
N1 1/2" NPT
F11 Blind flange DN50 PN16 (DIN 2501)
F12 Blind flange DN50 PN32 (DIN 2501)
F21 Blind flange 2" 150 lbs RF (/ANSI B 16.5)
F22 Blind flange 2" 300 lbs RF (/ANSI B 16.5)
Y others
Measuring accuracy
10 ±10 mm (±0.394")
5 ±5 mm (±0.197")
20 ±20 mm (±0.788")
Float type
A ‡52 mm; min. SG: 0,7 kg/dm³; max. p. 40 bar; mat.: 316Ti
B ‡80 mm; min. SG: 0,6 kg/dm³; max. p. 17 bar; mat.: Titanium
C ‡80x35 mm; min. SG: 0,5 kg/dm³; max. p. 13 bar; mat.: 316Ti
D ‡44x52 mm; min. SG: 0,8 kg/dm³; max. p. 25 bar; mat.: 316Ti
E ‡32x34 mm; min. SG: 0,55 kg/dm³; max. p. 10 bar; mat.: Buna N
F ‡32x34 mm; min. SG: 0,5 kg/dm³; max. p. 100 bar; mat.: Introx
Y others
Transmitter housing
A mat. cast aluminium, IP65 (NEMA 4/4X), standard
S mat. 316Ti, IP65 (NEMA 4/4X, standard
E mat. aluminium with epoxy finish, IP65 (NEMA 4/4X), EExd II C T6
Y other
Transmitter
T1 INT5333 non Ex
T2 TMT182 non Ex
T3 TMT182 Ex
T4 TMT184 Profibus

236
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

5.2 ITA-T1R Magnetic multi float-switch

Technical data
Max. operation pressure: 40 bar, depending on mounting type and float type
Max. temperature: 100 °C (213 °F)
Min. operation temperature: depending on the float type
Installation: vertical; ±30°
Protection class: IP65 (NEMA 4)
Weight: depending on version
Min. switch distance: float diameter + 30 mm
Dimensions:
L1: min. 30 mm (flanged version)
min. 50 mm (threaded version)
Lmax: 3000 mm

L2-L5: min. (float diameter + 20 mm)


A: min. 50 mm
Guide tube ‡: 14 mm
Order codes:
Code Description
ITA-T1R Magnetic Multi-Float-Switch
Material of guide tube
S 316Ti (1.4571)
Material of tank mounting
S 316Ti (1.4571)
C Carbon steel
Mounting type
R1 R1/2"
N1 1/2" NPT
F11 Blind flange DN50 PN16 (DIN 2501)
F12 Blind flange DN50 PN32 (DIN 2501)
F21 Blind flange 2" 150 lbs RF (/ANSI B 16.5)
F22 Blind flange 2" 300 lbs RF (/ANSI B 16.5)
Y others
Switches: 1 … 2 … 3 … 4 … 5 … 6 …
Switchpoint: ____ ____ ____ ____ ____ ____ (mm)
Float type
A ‡52 mm; min. SG: 0,7 kg/dm³; max. p. 40 bar; mat.: 316Ti
B ‡80 mm; min. SG: 0,6 kg/dm³; max. p. 17 bar; mat.: Titanium
C ‡80x35 mm; min. SG: 0,5 kg/dm³; max. p. 13 bar; mat.: 316Ti
D ‡44x52 mm; min. SG: 0,8 kg/dm³; max. p. 25 bar; mat.: 316Ti
E ‡32x34 mm; min. SG: 0,55 kg/dm³; max. p. 10 bar; mat.: Buna N
F ‡32x34 mm; min. SG: 0,5 kg/dm³; max. p. 100 bar; mat.: Introx
Y others
Connection Box
S Standard (max. 2 switches); IP65 (NEMA 4)
D EExd (max. 2 switches); IP65 (NEMA 4)
K Plastic (max. 6 switches); IP65 (NEMA 4)
A Aluminium (max. 2 switches); IP65 (NEMA 4)
Contacts
S normally open (NO)
Umax = 25 V, Imax = 150 mA
O normally closed (NC)

237
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Besides the products covered by this brochure, Intra-Automation GmbH also manufactures other high-
quality and high precision instruments for industrial measurement tasks. For more information, please
contact us (contact details on the backside of this brochure).

Flow Measurement

Cone Flowmeters

Itabar-Flow-Meters
Flow Nozzles

Venturi tubes Wedge Flowmeters

Level Measurement

Transparent type level gauge Reflex type level gauge Tubular type level gauge

Other measurement tasks

Intra-Automation provides a wide range of measurement and control instruments. For more information, please
contact us visit our homepage www.intra-automation.com.
Technical Catalogue ITA magnetically controlled liquid level indicator Intra-Automation

Headquarters: Subsidiary in the Netherlands:


(Germany, world-wide sales) (Sales in the Benelux-States)
INTRA-AUTOMATION GmbH BV INTRA-AUTOMATION HTP
Otto-Hahn-Strasse 20 Keulsveld 17
41515 Grevenbroich 4705 RS Roosendaal
GERMANY THE NETHERLANDS

+49-(0)2181-75665-0 +31-(0)165-322201
 +49-(0)2181-64492  +31-(0)165-322970
 [email protected]  [email protected]

Please also visit our homepage www.intra-automation.com.

You might also like