Quadoperational Am Pli Fi Ers: Uni Soni C Technologi Es Co., LTD
Quadoperational Am Pli Fi Ers: Uni Soni C Technologi Es Co., LTD
Quadoperational Am Pli Fi Ers: Uni Soni C Technologi Es Co., LTD
, LTD
QU AD OPERAT I ON AL
AM PLI FI ERS
DESCRI PT I ON
The UTC LM324 consists of four independent, high gain
internally frequency compensated operational amplifiers which are
designed specifically to operated from a single power supply over a
wide voltage range. Operation from split power supplies is also
possible. Application areas include transducer amplifier, DC gain
blocks and all the conventional OP amp circuits which now can be
easily implemented in single power supply system.
FEAT U RES
*Internally frequency compensated for unity gain.
*Large DC voltage gain :100dB.
*Wide operating supply range (VCC=3V~40V).
*Input common-mode voltage includes ground.
*Large output voltage swing: From 0V to Vcc-1.5V.
*Power drain suitable for battery operation.
ORDERI N G I N FORM AT I ON
Ordering Number
Package Packing
Lead Free Halogen-Free
LM324L-D14-T LM324G-D14-T DIP-14 Tube
LM324L-S14-R LM324G-S14-R SOP-14 Tape Reel
LM324L-P14-R LM324G-P14-R TSSOP-14 Tape Reel
M ARK I N G
DIP-14 SOP-14 / TSSOP-14
www.unisonic.com.tw 1 of 5
QW-R105-006.N
Copyright © 2017 Unisonic Technologies Co., Ltd
LM324 LINEAR INTEGRATED CIRCUIT
PI N DESCRI PT I ON
OUT 1 1 14 OUT 4
IN 1(-) 2 13 IN 4(-)
IN 1(+) 3 12 IN 4(+)
Vcc 4 11 GND
IN 2(+) 5 10 IN 3(+)
IN 2(-) 6 9 IN 3(-)
OUT 2 7 8 OUT 3
BLOCK DI AGRAM
IN (-)
Output
IN (+)
GND
80
Negative
Input Voltgae,VIN (±V)
10
Positive VCC=+15V
40
5
VCC=+5V
20
0 0
0 5 10 15 -50 -25 0 25 50 75 100
Supply Voltage (± V) Temperature (°C)
40 160
VCC
IC
RL=20kΩ
3 120
Supply Current (mA)
RL=2kΩ
2 80
TA=0~+85°C
1 40
TA=-40°C
0 0
0 10 20 30 40 0 7.5 15 22.5 30
VCC
100 100MΩ 100
0.1µF
VCC=+7.5V
Voltage Gain (dB)
80 80 VEE=-7.5V
VIN
CMRR (dB)
VCC/2
+7.5V
60 60
100kΩ
100Ω
40
VCC=30V
40 100Ω
VCC=15V VIN
20 100kΩ -7.5V
20
0
0
0 1 2 3 4 5 6 7 2 3 4 5 6
10 10 10 10 10 10 10 10 10 10 10 10 10
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.