Shalini Agarwal

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

BUILDING CONSTRUCTION

NOTES:

APEX

A
SPLICE
100 X75 X 8 ANGLE
CLEAT AS PURLINS
B

APEX BUTT WELD

DETAIL OF A
5000

PORTAL
FRAME
180 338 338 180

254 X 101 X22


KG U.B.PORTAL

SPLICE PLAN
C

254 X X 8 B.S.U.A
SECTION OF PORTAL FRAME CLEATE PORTAL RIB

125 X75 X 70 B.S.U.A.


EAVES ANGLE
100 X75 X 8 B.S.U.A
203 3151 PURLINS
254 X 101 X22 KG U.B. SPLICE SECTION
150 X 150 X 12 WEB
254 X 101 X22 KG U.B. PLATE
PORTAL
KNEE BUTT WELD
2970

460 X 80 X12 FLANGE 2070


PLATE

1665
765
254 X 101 X22 KG U.B. DAYALBAGH EDUCATIONAL
PORTAL 254 X 101 X22 KG U.B. INSTITUTE, AGRA (F.O.A)
BASE PLATE PORTAL SHALINI AGARWAL
2070 164408
2970
8th SEMESTER
PORTAL FRAME SYSTEM
DETAIL OF C DETAIL OF B DETAIL OF BASE PLATE TRUSSES
AR.UROOJ SIR
AR. JITENDRA DIWAKAR
BUILDING CONSTRUCTION
NOTES:

4.6 m
3.75 m 3.75 m 3.75 m 3.75 m 3.75 m 3.75 m 3.75 m 3.75 m

30 m

ELEVATION OF LATTICE GIRDER


SCALE 1:100
ROOF

NORTH LIGHT
TRUSSES
B

4.6 m
LATTICE
GIRDERS GLLAZING

A
11 m 11 m

SECTION AT X - X X
SCALE 1:100

ANGLES TO GIRDER (2/ 120 x 120 x 12 )


PATENT GLAZING BAR
GLASS
INSULATED ASBESTOS SHEETING
ANGLE RAIL ( 125 x 75 x 10)
LEAD FLASHINGS
EAVES FILLER PIECE
ANGLE PURLIN (90 x 65 x 10)
ANGLE CLEAT (100 x 100 x 10)
GUTTER (380 x 150)
GUTTER STRAPS AT 450 CENTRES (40 x 10)
6 MM FILLET WELD
ANGLES( 2/ 150 x 75 x 10)
X
GUSSET PLATE
ANGLES(65 x 50 x 8)
PLATE
LATTICE
ANGLE CLEATS(60 x 60 x 10) GIRDERS
(125 x 75 x 10) 30
DETAL AT A
m
SCALE 1:10 NORTH LIGHT
TRUSSES

ASBESTOS RIDGE CAPPING


ANGLE PURLIN (90 x 65 x 10)
LIGHT SECTIONS 1 m
1
ANGLE RAILS WELD TOGETHER SCALE 1:5
( 125 x 75 x 10)&(80 x 60 x 10)
FLASHING
ANGLE BRACKET(100 x 75 x 10)
ANGLES AS RAFETRS BACK TO
NORTH LIGHT TRUSS (2/150 x 75 x 10) DAYALBAGH EDUCATIONAL
PATENT GLAZING INSTITUTE AGRA(F.O.A)
GUSSET PLATE ISOMETRIC VIEW SHALINI AGARWAL
CLEAT (125 x 75 x 12)
SCALE 1:100 164408
ANGLES AS TOP BOOM
TO LATTICE GIRDER (2/125 x 75 x 12) 8th SEMESTER
GUSSET PLATE NORTH LIGHT TRUSS
Ar. UROOJ MEHENDI
DETAIL AT B HEAVY SECTIONS BUILT- UP SECTIONS Ar. JITENDER DIWAKAR
SCALE 1:10 SCALE 1:5 SCALE 1:5 SCALE: 1:100, 1:10 & 1:5
BUILDING CONSTRUCTION
VERTICAL REINFORCEMENT
NOTES:
SHOULD NOT BE LESS THAN
1% NOR MORE THAN 8% OF
CROSS-SECTIONAL AREA,
NOR LESS THAN 5. #4BARS

8" MIN. VERTICAL REINFORCEMENT TO BE NOT LESS


THAN 1% NOR MORE THAN 4% OF CROSS-SECTIONAL
AREA, OR LESS THAN 4-#4 BARS.

ROUND COLUMNS RECTANGULAR COLUMNS DOWELS TO TIE WALL


TO BEAM OR SLAB

SPACING TO BE NOT MORE


DOWELS THE COLUMN THAN 3" NOR LESS
TO SUPPORTED
BEMS AND SLABS. THAN 1 83" OR 1 12 SIZE OF
COARSE AGGREGATE.

WALLS MORE THAN 10" THICH


REQUIRE REINFORCEMENT IN
TWO LAYERS PLACED
PARALLEL WITH THE FACES OF
THE WALL
INCLINED BARS SHOULD NOT
EXCEED A 1 IN 6 SLOPE.
EXTEND SPIRAL HALF TURNS
BCM

EXTRA TIES MAY BE REQUIRED AT INTO COLUMN FOOTING.


SUPPORT POINTS. BCM

# 3" BARS MIN. SPACED NO


FURTHER THAN 3 X WALL
THICKNESS OR 18" A. C.

VARIES WITH COLUMN LOAD;12" MIN.

3"
6"

PILE CAP MAY BE USED FOR CONCRETE,


VERTICAL REINFORCEMENT HELPS COLUMN WOOD OR STEEL PILES, AND MAY SUPPORT
CARRY COMPRESSIVE LOADS AND RESISTS EITHER COCRETE OR STEEL COLUMNS. 3/4" MIN. COVER WHEN
TENSILE FORCES WHEN COLUMN IS SUBJECT CONCRETE IS NOT EXPOSE TO
TO LATERAL LOADS. 1 12" MIN. COVER GROUND OR WEATHER
(2" FOR # 6BARS AND LARGER)
WHEN CONCRETE IS EXPOSED
TO EARTH OR WEATHER
COLUMN TIES 8" MIN. FOR BASEMENT,
FOUNDATION, FIRE, OR
PARTITION WALLS.
VERTICAL REINFORCEMENT · 6" MIN. THICKNESS FOR
1
BEARING WALLS OR 25 OF THE
UNSUPPORTED DISTANCE
BETWEEN HORIZONTAL OR
SPACING TO BE NOT MORE THAN
VERTICAL STIFFENING
48 X TIE OR 16 X VERTICAL
BAR NOR MORE THAN LEAST ELEMENTS.
DIMENSION OF COLUMN SECTION.
· 4" MIN THICKNESS FOR
1
NONBEARING WALLS OR 36 OF WALLS IS TIED TO ITS FOOTING
UNSUPPORTED DISTANCE. WITH DOWELS BENT IN
ALTERNATE DIRECTIONS.
1 12" CLEAR COVER · 2" MIN. THICKNESS FOR
NONBEARING INTERIOR
COLUMN TIES PARTITIONS NOT USED AS SHEAR
ELEMENTS.
DOWELS OVERLAP VERTICAL BARS
40 BAR DIAMETERS OR 24"; EXTEND · 6" MIN. THICKNESS FOR
DOWN ENOUGH TO DEVELOP BOND. PLAIN (UNREINFORCED) WALLS
WITH A HEIGHT TO THICKNESS 6" MIN. THICKNESS ABOVE
RATIO OF LESS THAN 22. REINFORCEMENT (8" MIN. FOR
UNREINFORCED FOOTINGS.) DAYALBAGH EDUCATIONAL
3" MIN. COVER WHEN INSTITUTE, AGRA (F.O.A)
CONCRETE IS CAST AGAINST 3" MIN. COVER WHEN
3" AND PERMANENTLY EXPOSED CONCRETE IS CAST AGAINST SHALINI AGARWAL
TO EARTH. AND PERMANENTLY EXPOSED 164408
TO THE EATRH.
EXPOSED TO EARTH 8th SEMESTER
BASE AREA OF FOOTING DISTRIBUTES COLUMN
CONCRETE WALLS USUALLY SPEEDY CONSTRUCTION
REST ON A CONTINUOUS STRIP
LOAD TO ENSURE THAT BEARING CAPACITY OF R.C.C. COL. & WALL SYSTEM
FOOTING.
SUPPORTING SOIL IS NOT EXCEEDED.
AR.UROOJ SIR
EXAMPLES OF PILE CAP PLANS. CONCRETE WALL SECTION AR. JITENDRA DIWAKAR
COLUMN SECTION
BUILDING CONSTRUCTION
NOTES:
REINFORCED CONCRETE FLOOR SYSTEM
4"

SPAN/30 FOR FLOOR SLAB; 4"


SPAN/36 FOR ROOF SLABS
10"
ONE WAY SLAB
SECTION
4"

10"

30" 5"

ONE WAY SLAB ONE WAY JOIST SLAB


SECTION
4"

10"

5"
30"

TWO WAY WAFFLE SLAB


SECTION
JOIST BAND

REINFORCED CONCRETE
COLUMN

SOLID FLOOR AROUND COLUMN


TO RESIST SHEAR
ONE WAY JOIST SLAB
REINFORCED
CONCRETE MAIN
BEAM

TWO WAY REINFORCEMENT


TO CONCRETE FLOOR
MAIN BEAM

WAFFLE GRID FLOOR

REINFORCEMENT OF TWO WAY DAYALBAGH EDUCATIONAL


SPAN RIBS TO WAFFLE FLOOR 590 30
0
SOLID HEADS AT INSTITUTE, AGRA (F.O.A)
COLUMN SUPPORT SHALINI AGARWAL
112 .5
.5 112
164408
GLASS FIBRE REINFORCED PLASTIC MOULDS 8th SEMESTER
ARE NAILED TO CLOSE BOARDED CENTERINGAND G. R. P. MOULD
ARE STRUCK BY COMPRESSED AIR THROUGH SPEEDY CONSTRUCTION
TWO WAY WAFFLE SLAB HOLE IN TOP OF MOULD R.C.C. FLOOR SYSTEM
AR.UROOJ SIR
WAFFLE GRID IN-SITU CAST REINFORCED CONCRETE FLOOR AR. JITENDRA DIWAKAR
BUILDING CONSTRUCTION
REINFORCING BARS OF CAGE OF UPPER
COLUMN TO FIT INSIDE BARS OF LOWER TOP BAR IS PLACED IN CONTINOUS
COLUMN TO FORM OVERLAP 1.5" MINIMUM COVER BEAM IN AREAS OF UPWARD BONDING

DOWELS TO TIE INTO


1.5" MINIMUM COVER CONTINAUTION ABOVE
BEAM DEPTH
REINFORCED 1"MINIMUM OR NOT LESS THAN
CAGE OF HOOKED OR 90 DEGREEBEND
1.3 X NORMAL BAR DIA OR TO TRANSFER TENSILE STRESS
SECONDARY COURSE AGGREGATE AT BEAM ENDS
BEAM
1.5" MINIMUM COVER WIDTH IS 1 3 OR 1 2 BEAM DEPTH
REINFORCING STEEL IS PLACED
IN 2" OR 3" MULTIPLE
IN AREAS OF TENSILE STEEL

STIRRUPS ARE REQUIRED TO HANDLE


REINFORCED CONCRETE BEAMS SECTION DIAGONAL TENSION AT BEAM SUPPORTS

PLYWOOD SHEATHING
INNER SURFACE OF PANELS REINFORCED CONCRETE BEAMS
LEAVES AN IMPRESSION ON
THE CONCRETE
2X4
STUDS

LACING BARS TO REINFORCEMENT


PROVIDE CAGE FOR
STRUCTURAL INTERNAL
CONTINUITY COLUMN

REINFORCEMENT CAGES OF
BCM

ITERNAL COLUMNS AND BEAMS WOOD RUSTICATION STRIPS ARE


USED TO FORM RECESSES IN THE
WALL SURFACE.
THESE STRIPS ARE ALSO
AVAILABLE AS PARTS OF
PLASTIC FORMLINER SYSTEMS

LINKS TO FORM
REINFORCED CAGE BRACING

SILL PLATE SINGLE OR DOUBLE


CONCRETE 2 X 4 WALERS

CONCRETE WALLS : FORM WORK

1
1 8"
VARIES
LINEAR RECESSES CAN BE 2"
REINFORCED USED TO ARTICULATE A
CONCRETE WALL'S SURFACE PATTERN,
BEAM SEPARATE DIFFERENT WALL
SURFACE TREATMENTS
AND TO HELP CONCEAL
GROOVE DETAIL: B EPOXY
CONSTRUCTION JOINTS. EXPOSED
TIE END. · TIE HOLES MAY BE:
REINFORCED REINFORCED
CONCRETE CONCRETE
BEAM · PATCHED TO MATCH
COLUMN SURROUNDING.
B DAYALBAGH EDUCATIONAL
· LEFT EXPOSED
INSTITUTE, AGRA (F.O.A)
· FILLED WITH PLASTIC CAP.
A SHALINI AGARWAL
164408
UPPER COLUMN CAGE SPLICED TO 8th SEMESTER
LOWER CAGE OF CONCRETE COLUMN SPEEDY CONSTRUCTION
R.C.C. BEAM. & WALL SYSTEM
GROOVE DETAIL: A CONCRETE WALLS :ELEVATION AR.UROOJ SIR
AR. JITENDRA DIWAKAR

You might also like