0% found this document useful (0 votes)
118 views2 pages

Geotextile How To Use

This document is a laboratory test report from TRI Suzhou to Shandong Tinhy New Materials Engineering Co. summarizing the results of conformance testing on a nonwoven geotextile sample. Tests were performed for thickness, mass per unit area, tensile strength, tear resistance, puncture resistance, and permeability. The report provides the test methods, materials description, individual test results, averages, and notes that the sample tested is believed to represent the material produced under the given designation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
118 views2 pages

Geotextile How To Use

This document is a laboratory test report from TRI Suzhou to Shandong Tinhy New Materials Engineering Co. summarizing the results of conformance testing on a nonwoven geotextile sample. Tests were performed for thickness, mass per unit area, tensile strength, tear resistance, puncture resistance, and permeability. The report provides the test methods, materials description, individual test results, averages, and notes that the sample tested is believed to represent the material produced under the given designation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Mar 23rd, 2020

Betty Wang
Shandong Tinhy New Materials Engineering Co., Ltd.
Diaozhen Chemical Industrial Park of Zhangqiu / Steve Xi #: 79
Jinan City, Shandong Prov. China
03/23/2020

Re: FINAL LABORATORY TEST REPORT

Dear Ms. Wang:

Thank you for consulting TRI Suzhou for your material testing needs.

Enclosed is the final laboratory report for the Conformance testing of one (1) Nonwoven Geotextile sample.

PROJECT NAME: Geotextile Testing DATE REPORTED: Mar 23rd, 2020


REFERENCE TRI JOB NO.: SCH20053

DATE RECEIVED: Mar 20th, 2020

SAMPLE(S) SENT BY: Tinhy New Materials

SAMPLE IDENTIFICATIONS:
SAMPLE ID TRI CONTROL NUMBER
Nonwoven Geotextile 02127

TESTS REQUIRED / PERFORMED:


TEST METHOD DESCRIPTION
1. ISO 9863 Thickness
2. ISO 9864 Mass per Unit Area
3. ISO 10319 Wide Width Tensile
4. ISO 9073.4 Trapezoidal Tear Resistance
5. ISO 12236 CBR Puncture
6. ISO 11058 Permittivity

TEST RESULTS: The test results are summarized in the attached Table(s) 1.

Respectfully,

TRI Geosynthetic Testing and Services (Suzhou) Co., Ltd.

Steve Xi Chad Blackwell


Quality Assurance General Manager Signatures are on file

It shall be noted that the sample/s tested is/are believed to be true representatives of the material produced under the designation herein stated. In addition, the attached

laboratory tests results are considered indicative only of the quality of samples/specimens that were actually tested. The appropriate test methods hereby employed are based

on the current and accepted industry practices. TRI neither accepts responsibility for nor makes claims to the intended final use and purpose of the material. The test data and

all associated project information shall be held confidential and not to be reproduced and/or disclosed to other parties except in full and with prior written approval from the client

or any pertinent entity duly authorized by the respective client. It is our policy to keep physical records of each job for five (5) years commencing from the date of receipt of the

samples and keep its corresponding electronic file for seven (7) years. Retained conformance samples are disposed of after one (1) month. On the other hand, should you

need us to keep them at a longer period, please advise us in writing.

2 Pages Total (including this sheet)

Room 113 A2, 218 Xinghu Road BIOBAY SIP, Suzhou, Jiangsu Prov. , www.precisionlabs.net
江苏苏州工业园区星湖街 218 号生物纳米园 A2 楼 113 室
TABLE 1.
MATERIAL PROPERTIES
CLIENT: Shandong Tinhy New Material
PROJECT: Geotextile Testing

Date Received: 2020.03.20 QC'd By:


Date Reported: 2020.03.23 TRI Job No.: SCH20053
Client Sample ID: White Nonwoven Geotextile TRI Control No.: 02127
Material Description: White Nonwoven Geotextile
SPECIMENS

1 2 3 4 5 6 7 8 9 10 Avg. Std. Dev. Min Max


METHOD DESCRIPTION
ISO 9863 Thickness (mm)
3.39 3.20 3.80 3.21 3.32 3.27 3.11 3.03 3.53 3.73 3.36 0.26 3.03 3.80
ISO 9864 Mass per Unit Area (gm/ m2)
353.4 325.3 302.6 330.7 334.0 346.6 317.1 349.1 321.5 317.1 329.2 18.3 302.6 353.4
ISO 10319 Wide-Width Strip Tensile
Tensile Strength (kN/m)
MD 15.3 16.1 16.1 14.3 12.7 14.9 1.4 12.7 16.1
TD 13.6 13.4 13.6 16.8 17.6 15.0 2.0 13.4 17.6
Elongation at Break (percent)
MD 63 65 63 60 61 63 2 60 65
TD 70 83 67 76 69 73 7 67 83
ISO 9073.4 Trapezoid Tear Strength (N)
MD 325 427 364 431 348 379 48 325 431
TD 319 344 353 417 375 362 37 319 417
ISO 11058 Permittivity (sec.-1)
Constant Head 0.95 1.01 1.04 1.02 1.01 1.01 0.03 0.95 1.04
50mm Permeability (cm./ sec.)
0.29 0.32 0.34 0.32 0.40 0.33 0.04 0.29 0.40
Flow Rate (l/sec/m2)
48 51 52 51 51 50 2 48 52
ISO 12256 Static Puncture Strength (N)
2701 3064 2922 2762 2715 2833 156 2701 3064

End of Table 1 (Sheet 1 of 1)

By accepting the data and results presented on this report, the Client agrees to limit the liability of TRI SUZHOU from Client and all other related parties for any claims on issues, due to the use of this data, to the cost respective of
the tests presented in this report; and the Client agrees to indemnify and hold harmless TRI SUZHOU from and against all liabilities in excess of the aforementioned limits.

MD - MACHINE DIRECTION Room 113 A2, 218 Xinghu Road BIOBAY SIP, Suzhou, Jiangsu Prov., www.precisionlabs.net
TD - TRANSVERSE DIRECTION 江苏苏州工业园区星湖街218 号生物纳米园A2 楼 113 室

You might also like