0% found this document useful (0 votes)
312 views4 pages

Real Eigenvalue Extraction Data

This document defines the data needed to perform real eigenvalue analysis, which can be used for vibration or buckling analysis. The data includes fields like the frequency or eigenvalue range of interest, the number of roots desired, convergence tolerances, and solver options. Example values and default settings are provided for each field.

Uploaded by

dotiep88
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
312 views4 pages

Real Eigenvalue Extraction Data

This document defines the data needed to perform real eigenvalue analysis, which can be used for vibration or buckling analysis. The data includes fields like the frequency or eigenvalue range of interest, the number of roots desired, convergence tolerances, and solver options. Example values and default settings are provided for each field.

Uploaded by

dotiep88
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 4

Real Eigenvalue Extraction Data

Description: Defines data needed to perform real eigenvalue (vibration or buckling) analysis.

Format:

Example:

Field Definition Type Default

SID Set identification number. Integer > 0 Required


V1, V2 For vibration analysis: frequency range Real or blank, V1 < See Remark 5
of interest. For buckling analysis: V2
eigenvalue range of interest.
ND Number of roots desired. Integer > 0 See Remark 5
SCHECK Sturm sequence check, one of the Character AUTO
following character variables: YES, NO,
or AUTO. See Remark 7.
NIVEC Number of iteration vectors. See Remark Integer > 0 See Remark 8
8.
SHFSCL Estimate of the first flexible mode Real or blank See Remark 9
natural frequency. See Remark 9.
NORM Method for normalizing eigenvectors, Character MASS - for
one of the following character variables: vibration
MASS or MAX analysis
MASS Normalize to unit value of
MAX - for
the generalized mass. Not
buckling
available for buckling
analysis
analysis.
MAX Normalize to unit value of
the largest eigenvector
Field Definition Type Default

displacement.

MAXITER Maximum number of iterations. See Integer ≥ 0 0


Remark 10.
CTOL Eigenvalue convergence tolerance. Real or blank See Remark 11
ADDITER Number of additional iterations after Integer ≥ 0 1
convergence. See Remark 12.
ADDIVCV Number of additional iteration vectors Integer ≥ 0 5
past the number of roots desired or the
included range of interest that must also
converge. See Remark 12.
CTRLOPT Controls solver specific operations 1 ≤ Integer ≤ 4 See Remark 13
during eigenvalue extraction. See
Remark 13.
ORTOPT Option for full or partial mass re- Character AUTO
orthogonalization after each Lanczos
iteration, one of the following character
variables: FULL, PARTIAL, or AUTO.
See Remark 14.
Remarks:

1. Real eigenvalue extraction data sets must be selected with the Case Control
command METHOD = SID.
2. The units of V1 and V2 are cycles per unit time in vibration analysis, and are eigenvalues in
buckling analysis. In buckling, each eigenvalue is the factor by which the prebuckling state of
stress is multiplied to produce buckling in the shape defined by the corresponding eigenvector.
3. NORM = MASS is ignored in buckling analysis and NORM = MAX will be applied.
4. Eigenvalues are sorted on order of magnitude for output. An eigenvector is found for each
eigenvalue.
5. In vibration analysis, if V1 < 0.0, the negative eigenvalue range will be searched.
(Eigenvalues are proportional to Vi squared; therefore, the negative sign would be lost.) This is a
means for diagnosing improbable models. In buckling analysis, negative V1 and/or V2 require no
special logic.
6. The roots are found simultaneously and sorted in increasing order for each subspace or Lanczos
iteration. The number and type of roots to be found can be determined from the following table.

V1 V2 ND Number and Type of Roots Found

V1 V2 ND Lowest ND roots or all in range,


whichever is smaller
V1 V2 ND Number and Type of Roots Found
V1 V2 blank All in range
V1 blank ND Lowest ND roots in range [V1, + ∞ ]
V1 blank blank Lowest root in range [V1, + ∞ ]
blank blank ND Lowest ND roots in range [- ∞ , + ∞ ]
blank blank blank Lowest root
blank V2 ND Lowest ND roots below V2
blank V2 blank All below V2
7. SCHECK controls whether a Sturm sequence check is performed. The Sturm sequence
check determines if any roots were missed during eigenvalue extraction. Setting SCHECK equal
to 0 or NO skips the Sturm sequence check and avoids an additional stiffness matrix
factorization thus reducing analysis time. Setting SCHECK equal to 1 or YES performs the check
and will output a warning message if any modes were missed. The default setting of AUTO will
always perform the check when the subspace eigensolver is selected and only for models
smaller than EXTRACTAUTOSIZE when the Lanczos eigensolver is selected. (See Section
2, Initialization, for more information on EXTRACTAUTOSIZE.)
8. When the subspace eigensolver is selected, NIVEC specifies the number of additional
iteration vectors and is defaulted to 12. Increasing this value may result in a lower number of
subspace iterations required but will require more memory and more solves per subspace
iteration. When the Lanczos eigensolver is selected, this option controls the Lanczos block size
and the default is determined automatically. A value of 9 or 12 may increase performance for
models where a large number of modes will be extracted. The maximum value for the Lanczos
eigensolver is 120.
9. Specifying SHFSCL = 0.0 may improve accuracy and performance. If this field is blank, a
non-zero value for SHFSCL is estimated automatically to handle unconstrained or poorly
constrained structures in vibration analysis.
10. MAXITER is used to limit the number of subspace or Lanczos iterations to be performed.
The default zero setting forces the eigensolver to iterate until convergence is reached.
11. The CTOL default is dependent on the OPTIMIZESETTINGS directive setting. The following
table gives the various values. The default for OPTIMIZESETTINGS is NONE.

OPTIMIZESETTINGS
Value CTOL Value

SPEED 1.0E-5
ACCURACY 1.0E-7
BOTH 1.0E-6
NONE 1.0E-6
12. ADDITER and ADDIVCV are used to prevent missing roots. ADDITER defines the number of
additional iterations that will be forced even after all roots desired have converged. ADDIVCV
defines how many roots past the desired number or range of interest must converge. A value
greater than 1 is recommended when roots are closely spaced. Larger values may result in
additional subspace iterations.
13. CTRLOPT controls where the Lanczos eigensolver intermediate results are stored (in
memory or on disk) and what solver mode is used (iterative or direct). Higher settings require
more memory but may increase performance significantly. The default setting is the eigensolver
selects the best method based on available memory. If the SPARSEITERMETHOD model
parameter is set to DIRECT, the default will be a CTRLOPT setting of 4. If set to ITERATIVE and
the model consists of mostly parabolic tetrahedron elements, the default will be a setting of 1.
(See Section 5, Parameters, for more information on SPARSEITERMETHOD.) The following
table gives the various options.

Intermediate File Storage


CTRLOPT Setting Location Solver Mode

1 Disk Iterative
2 Memory Iterative
3 Disk Direct
4 Memory Direct
14. ORTOPT controls whether a full or partial mass re-orthogonalization is performed after each
Lanczos iteration. Partial re-orthogonalization increases performance for models where a large
number of modes (greater than 100) are requested. Partial re-orthogonalization, however, may
result in a small degradation in accuracy. The AUTO setting will use partial re-orthogonalization
when residual vectors are requested via the RESVEC model parameter or for models larger than
EXTRACTAUTOSIZE when either an eigenvalue range is specified or the number of modes
requested is greater than 100. (See Section 2, Initialization, for more information
on EXTRACTAUTOSIZE and Section 5, Parameters, for more information on RESVEC.)