Release Notes
Release Notes
33
--------
Delivered (d/m/y):21/02/2013
PC/NT : S00x.exe, 16749056 bytes
- New functionality: -
----------------------
PF9100214533 5 - Enhancement Support ZLA character set for FI GS
PF9100202787 6 - not applicable CMR: AAT full brake test adaption
to 2.5 m/s - SW
Bugfix Corrected:
-------------
PF9100214452 1 - Critical KTHMH is ignored in BR2 CN
PF9100215034 1 - Critical JPN: Door open between floor if KTL is
still active
PF9100214323 2 - Major DI / PI, Interlocked door mode: RPHT reversing
causes E_DOOR_SHAFT_ERROR when on
PF9100213834 2 - Major Cadi - Simcard downloader .sco file download
fails on V9.92
PF9100214317 2 - Major Fix blocked situation in case
E_DOOR_SHAFT_ERROR with PI Policy and Interlocked
PF9100214685 2 - Major Door error does not terminate in case of
E_DOOR_MAX_LOCK_TIME
PF9100071434 2 - Major CMR: EEprom conversion - SW update failed and
CPU blocked
PF9100214925 2 - Major JPN: After Reset Inputs on the SAIO2 are not
set back to the previos value
PF9100214259 3 - Average DCN - perform door close with RPHT device, RPHT
is not enabled after DTO pressed
Improvement
-------------
PF9100213064 2 - Major Controller SW supports NXP3/NXP2 gobal release
- SW
PF9100215310 5 - Enhancement OEM levels updates for V9.94
PF9100214578 6 - not applicable Workshop 201212:Automatic enable
logging after a reset
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.93.32
--------
Delivered (d/m/y):19/11/2012
PC/NT : S00x.exe, 16762368 bytes
N/A
- New functionality: -
----------------------
PF9100192648 5 - Enhancement "Output of SDIC_IDENTIFY_BL is Unknown
command in CADI (Resubmitted: SDIC 5v3.2 S00x V9.93 DP7 wundervi"
Bugfix Corrected:
-------------
PF9100071413 2 - Major CMR: Missing messages to RMCC and undefined OEM
policy status
PF9100213978 2 - Major FSEF TYPE0 ACTIVATION BY DAC - EVACUATION TO
NEXT FLOOR & CANCELLING CALLS IN E
PF9100204315 2 - Major arrival gong in car: two tones in UP
direction,4 tones in DOWN dirction
PF9100213862 3 - Average Fire Emergency Recall performed to secondary
floor after mains power OFF/ON with
PF9100214098 3 - Average Wrong service representation on Terminal
PF9100214108 3 - Average Check for configured outputs in Landing Panels
if broadcast floors
PF9100214092 4 - Minor Extend IO status menu for the location up to 35
floors, add missing BMKs
Improvement
-------------
PF9100214015 3 - Average For ZZ2 and ZZ3 Door announcements are sent for
each side specific COP
PF9100203288 5 - Enhancement I3206.1 Trip simulation with countdown
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.93.31
--------
Delivered (d/m/y):15/11/2012
PC/NT : S00x.exe, 16672256 bytes
- New functionality: -
----------------------
PF9100203794 3 - Average Graceful fatal no more working - SW
PF9100213739 5 - Enhancement EEPROM conversion V9.93
PF9100192602 6 - not applicable V9.83 CCU-COP integration support
new SCCI2 and SCMI - SW (Re-Submitted)
Bugfix Corrected:
-------------
PF9100071419 1 - Critical CMR: Cop configuraiton lost elevator
unusable
PF9100192642 2 - Major BR4 HK: after power OFF/ON elevator remains
blocked (Re-Submitted)
PF9100213860 2 - Major KTHMT has higher priority than BR1-JP
PF9100200713 2 - Major AAT mode : elevator open a door at bottom floor
- SW
PF9100213971 2 - Major wrong COP mode is set
PF9100213984 3 - Average Logging: service executor logs are not enabled
with list_mode:=2
PF9100192638 3 - Average P6101.6 PBEA(JP)[DOB] Automatic Evacuation with
Elevator Backup Power Supply - C
PF9100213859 3 - Average After timeout of door final timer the buzzer on
COPH does not sounds as long as
Improvement
-------------
PF9100213902 2 - Major BUILD: add static code check to BIONIC build
PF9100213845 2 - Major SDIC5:FW-version 3rd value V3.02.xx
PF9100180940 3 - Average COP-HB service shall be suspended in case
Maintenance service like AAT, Configur
PF9100213931 3 - Average Replace DE_U and DE_D bmk output to new correct
LE_U and LE_D bmk
PF9100213840 3 - Average Improve Landing on Next Possible Floor for
Forced Stop on Each Floor
PF9100213174 5 - Enhancement Add description for IO Handler interface,
COP Package interface and Door Package interface.
PF9100204666 6 - not applicable Workshop 201209: Part 1: Remove
TempCOP Brigde
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.93.30
--------
Delivered (d/m/y):5/11/2012
PC/NT : S00x.exe, 16657408 bytes
N/A
- New functionality: -
----------------------
Bugfix Corrected:
-------------
PF9100071416 1 - Critical CMR:Bio Bus nodes acknowledge not working
on 2 floors
PF9100192640 2 - Major serviceKLSUD: don't exit for levels with two
available sides (Re-Submitted)
PF9100071424 2 - Major CMR: CADI Connection not ok if duplex option is
enabled
PF9100201165 2 - Major <BR4 HK> After Syncronization Trip the DTO is
not Working as aspected to V9.9 (R
PF9100200797 2 - Major BR4 HK: after power OFF/ON elevator remains
blocked
PF9100213785 3 - Average ForcedStopOnEachFloor: Car move to wrong floor
if current Level is equal destina
PF9100213722 3 - Average RPHT does not work at second time after final
timer elapses.
PF9100180276 3 - Average EBR1 Active, KTHMH activated and deactivated ,
Elevator doesn't return in Normal
PF9100213613 3 - Average CF15PA1x cannot be left with ESC Button
PF9100213778 4 - Minor Improvement showing speed on HMI
Improvement
-------------
PF9100213695 2 - Major Secure input on BIO1 master node shall be
configurable
PF9100213692 5 - Enhancement Update Menu 301 for PA13 of CF12
PF9100204665 6 - not applicable Workshop 201209: Refactor function
flow of NextPossibleDestination
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.93.29
--------
Delivered (d/m/y):29/10/2012
PC/NT : S00x.exe, 16650240 bytes
N/A
- New functionality: -
----------------------
Bugfix Corrected:
-------------
PF9100192632 2 - Major SDIC5: Interlocked doors - Blocked in normal
operation
PF9100213616 3 - Average Floor call with worng side, lop configuration
not known
PF9100071421 3 - Average CMR: ADV Log message buffer dumping works with
wrong message numbers
PF9100213611 3 - Average Car position display on cop 4 does not work
PF9100213281 3 - Average assertion E BUSERR @ 0x302E07C8
Improvement
-------------
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.93.28
--------
Delivered (d/m/y):18/10/2012
PC/NT : S00x.exe, 16629760 bytes
N/A
- New functionality: -
----------------------
PF9100213274 5 - Enhancement P3220.4 FR�(JP)�[RGM] Fire Emergency
Recall - Amendement� - SW
Bugfix Corrected:
-------------
PF9100204481 2 - Major JRV : elevator in irv serves restricted access
PF9100192623 3 - Average ZZ2 - car blocked in 01 status-SIM car call
terminal command not work (Re-Submit
PF9100204679 3 - Average P6101.6 PBEA(JP)[DOB] Automatic Evacuation with
Elevator Backup Power Supply - C
PF9100124667 3 - Average correction cancel NF1 function
PF9100201072 3 - Average Tunneling in Firefighter with Interlocked Door.
Improvement
-------------
PF9100213532 3 - Average Improve communication with Cadi over RS232
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.93.27
--------
Delivered (d/m/y):04/10/2012
PC/NT : S00x.exe, 16625664 bytes
N/A
- New functionality: -
----------------------
PF9100179858 3 - Average P2208.2 DTA[GLOB] Adaptive Door Timing -
Overlay integration
PF9100213249 3 - Average Traffic: support Combo + Twin calls
PF9100204771 5 - Enhancement P4412.1 BDOX Push Button Door Open
Extended - button backlight - SW Door package
PF9100203720 5 - Enhancement P4412.1 BDOX Push Button Door Open
Extended - button backlight - SW
PF9100204133 6 - not applicable SG AAT35: display the max tripping
speed of safety gear and increase the delay t
Bugfix Corrected:
-------------
PF9100213148 1 - Critical Special Policy does not consider 2nd Side
when car move completed
PF9100204178 1 - Critical PI - ZZ3/ZZ2 - Blocked with pending car
call to V9.9
PF9100204752 2 - Major P3108.1 EAQ(JP) [JEB, LMH] Earthquake Operation
- after AES1 is done EB1 still a
PF9100204736 2 - Major P4501.5 DCN - DTO enabled for JP market - DTO
does not reopen the door
PF9100204417 2 - Major LiftA appeared the strange operation when car
call & landing call active togethe
PF9100204553 3 - Average Status 73 - Door opening recovrey
PF9100180168 3 - Average zz3 mode: no reversing with CC DTO on floor
with two side
PF9100126460 3 - Average Final Timer doesn't work After fire
deactivation.
PF9100071415 3 - Average CMR: Unexpected application reset
PF9100202723 3 - Average resubmitted:motorovertemp.:in ZZ3 both doors
opens to V9.91 (Re-Submitted)
PF9100179970 4 - Minor ZZ3 mode:door open and close two times during
VISIT OPERATION on unprotected sid
PF9100204542 4 - Minor Correction in JRVC elevator cancel car call to
V9.9
PF9100203324 4 - Minor problem with CC and floor call via HMI
Improvement
-------------
PF9100179427 3 - Average JLC and JVEC independent from SIAP
PF9100204667 6 - not applicable Workshop 201209: Part 2: Remove
TempCOP Bridge
PF9100204200 6 - not applicable STMM: Bmk code to extend to 9999 -
SW
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.93.26
--------
Delivered (d/m/y):12/09/2012
PC/NT : S00x.exe, 16154624 bytes
N/A
- New functionality: -
----------------------
PF9100203817 2 - Major CIR: BR4 MY(Malaysia) Firefighting function
(K625343 E/02 - SW
PF9100203976 6 - not applicable Advanced Logging: add detailed logs
Bugfix Corrected:
-------------
PF9100164803 2 - Major Interlock Doors, DTO don't open the door in
landings with one door side
PF9100203915 2 - Major SCPU damaged during update (BL procedure to be
improved)
PF9100164821 3 - Average CF_DUMP terminal command leads to an assertion
PF9100164812 3 - Average JAB input on CANIO board did not work anymore
PF9100164811 3 - Average Sim Card option "Parallel Doors old" is not
supported anymore
PF9100204236 3 - Average Evacuation (landing) to next possible floor
should correctly handle blind floors
PF9100181174 3 - Average ZZ2 : same Pin Code doesn't work for both
Side.
Improvement
-------------
PF9100204237 2 - Major Use redundant information to find available
doors in the emergency cases.
PF9100204275 2 - Major Use redundant information to find available
doors in the emergency services.
PF9100201463 3 - Average Restrict level accessible after parking
PF9100204256 3 - Average Move avay from restricted floor in case of
invoked correction service
PF9100192586 3 - Average <Door error handling>While KET-S signals door
open after doors close command is
PF9100202475 3 - Average DOOR_ENABLE_MASK for independent door sides
PF9100204218 5 - Enhancement P3108.1 EAQ(JP) [JEB, LMH] Earthquake
Operation - KEBH Amendment - SW (Re-Submit
PF9100204255 5 - Enhancement M1301.2 CPCOR [OD] - Handle Services for
Correction JP - SW (Re-Submitted)
Resolved without SW changes:
------------------
PF9100204496 3 - Average JKLBL (ZBC2) - ER message on COP5 to V9.9
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.92.25
--------
Delivered (d/m/y):26/07/2012
PC/NT : S00x.exe, 19265536 bytes
N/A
- New functionality: -
----------------------
PF9100204078 3 - Average P4612.1 P4612.2 FSEF Forced stop at each floor
- should be no evacuation to mai
Bugfix Corrected:
-------------
PF9100204063 1 - Critical KLS-D triggers as emergency stop and
leaves teh doors closed
PF9100204068 2 - Major safety chian error handling on restricted floor
(Re-Submitted)
PF9100164801 3 - Average Exeption by printing out terminal command "6"
PF9100204085 3 - Average Change sim card cmd for new FC and Function
parameter
Improvement
-------------
PF9100203940 2 - Major SG AAT35: display the max tripping speed of
safety gear and increase the delay time - Parent
PF9100164802 3 - Average Minimal rated load in CF99 is 180 kg
Rejected:
-------------
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.92.24
--------
Delivered (d/m/y):19/07/2012
PC/NT : S00x.exe, 19343872 bytes
N/A
- New functionality: -
----------------------
PF9100203749 3 - Average P4612.1 P4612.2 FSEF Forced stop at each floor
- evacuation to main problems -
PF9100203750 3 - Average P4612.1 P4612.2 FSEF Forced stop at each floor
- evacuation to main call regist
PF9100203787 5 - Enhancement EEPROM conversion V9.92
PF9100179107 6 - not applicable P4612.1 P4612.2 P4613.1 FSEF Forced
stop at each floor - SW
Bugfix Corrected:
-------------
PF9100203670 2 - Major DDC: door opens without reason canceling a car
call
PF9100203427 2 - Major safety chian error handling on restricted floor
PF9100203629 3 - Average P4503.4 AN [CDIR] - Anti-Nuisance [Cancel call
at change of direction] - problem
PF9100203779 3 - Average P4503.4 AN [CDIR] - Anti-Nuisance [Cancel call
at change of direction] - problem
PF9100203801 3 - Average cf_dump should not start CLC measurements V9.9
PF9100203803 3 - Average Door State on HMI: in some cases door state on
HMI is wrongly displayed
PF9100203807 3 - Average AAT RuntimeLimiter problem with PHNR shaft
types
PF9100203232 3 - Average elevator announce two times "car is overloaded"
Improvement
-------------
PF9100203725 1 - Critical M2629.1 MTLO Monitor terminal landing
overrun - input NC - SW
PF9100203111 2 - Major Drive: SMT 2 (�Do Final Positioning�) is not
implemented according the specification in the learning trip
PF9100203907 3 - Average UCM - Acceptance Test for BX HYD to V9.92
PF9100203610 3 - Average P4718.1 ILVC Leave car indication -
announcement together with light - SW
PF9100203654 3 - Average P6101.6 PBEA(JP)[DOB] Automatic Evacuation with
Elevator Backup Power Supply - m
PF9100203861 3 - Average Avoid possible assert in CL correction trip
PF9100203864 3 - Average Avoid unnecessary FC mode settings in Menu 102
PF9100201141 3 - Average <Door error handling>While KET-S signals door
open after doors close command is
Rejected:
-------------
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.92.23
--------
Delivered (d/m/y):05/07/2012
PC/NT : S00x.exe, 19354624 bytes
N/A
- New functionality: -
----------------------
PF9100203113 2 - Major Drive: the "SETTING_PARAMETER" state is ignored
by the EC
PF9100164404 3 - Average Brake Voltage OK input for SMICE32
Bugfix Corrected:
-------------
PF9100203696 1 - Critical COPPI: COP_ALARM_BUTTON msg is not
supported
PF9100203603 1 - Critical If the synchro is interrupted by safety
chain open it is not resumes (after safe
PF9100203594 1 - Critical Fixed (DT-O, DT-S, DTO Backlight...) IOs
and configurable IOs do not work with t
PF9100203630 2 - Major Graceful fatal no more working - SW
PF9100203604 2 - Major Watchdog led is not blinking!!
PF9100203772 2 - Major Outputs on single COPH do not work after a
controller reset
PF9100203507 2 - Major extended DTO TIMER isn't disable during
activation of BR1 JP
PF9100203576 2 - Major P3220.4 FR (JP) [RGM] Fire Emergency Recall -
Wrong handling of REFEHx - SW
PF9100203612 3 - Average P4410.1 PD [] Partition Door, Change KTTC to an
secure input - SW
PF9100202793 3 - Average wrong CPID on COP during 2min timeout of safety
chain recovery
PF9100203423 3 - Average HMI door state display: wrong indication during
normal mode
PF9100203686 3 - Average P6101.6 PBEA(JP)[DOB] Switch off carlight and
Fan in case of automatic evacuatio
PF9100202700 3 - Average carlightt sensor isn't detect (Re-Submitted)
PF9100203080 3 - Average NO_ERROR entry with 000000 date
PF9100203649 3 - Average Restricted Access (Card Reader) (ZB2 JPN) - PCI
works only after contoller reset
PF9100203602 3 - Average After the recall the learning is not started
automatically
PF9100203601 4 - Minor P3220.4 FR (JP) [RGM] Fire Emergency Recall -
New default for CF2PA9 - SW
Improvement
-------------
PF9100203608 1 - Critical Car direction configurable on COPPI
PF9100203651 2 - Major Service, getEmergencyDoorSide, should be
supported the case when the current lev
PF9100203664 3 - Average Overload derating for Japan - SW
PF9100203695 3 - Average ZZ2 and ZZ3 set door cmd close to the other
door that is not opened
PF9100203599 4 - Minor P3108.1 EAQ(JP) [JEB, LMH] Earthquake Operation
- LEB is not switched on after a
PF9100203600 4 - Minor P3108.1 EAQ(JP) [JEB, LMH] Earthquake Operation
- activating EB JP while door ar
PF9100203579 5 - Enhancement P3108.1 EAQ(JP) [JEB, LMH] Earthquake
Operation - Imporvements for phase |||- SW
PF9100203698 5 - Enhancement P3108.1 EAQ(JP) [JEB, LMH] Earthquake
Operation - Imporvements for phase |V- SW
PF9100203635 5 - Enhancement M1301.2 CPCOR [OD] - Handle Services for
Correction JP - SW
PF9100203648 5 - Enhancement P4207.1 EUNEF - LSI is not switched off
if recall/inspection is on during fatal
Rejected:
-------------
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.92.22
--------
Delivered (d/m/y):20/06/2012
PC/NT : S00x.exe, 19339264 bytes
N/A
- New functionality: -
----------------------
PF9100202237 5 - Enhancement P4404.2 BDC [MEM] Door Close by
button�[With memory] - SW
PF9100202602 5 - Enhancement P3220.4 FR (JP) [RGM] Fire Emergency
Recall - SW
PF9100203524 5 - Enhancement P3220.4 FR (JP) [RGM] Fire Emergency
Recall - updates - SW
Bugfix Corrected:
-------------
PF9100202692 1 - Critical P3220.1 FR(JP)[RG] Fire emergency recall
type 1 - KTL support - resubmit - SW
PF9100203287 1 - Critical Crash in startup
PF9100202907 2 - Major BR3-IN Fireman operation malfunction to V9.92
PF9100203539 2 - Major Second COPH is not detected after power off/on
PF9100202221 3 - Average Controller reset in Attendant Contol and SHAFT
DOOR_ERROR
PF9100203194 3 - Average Improve sending OEM status changes to RMCC
PF9100203318 3 - Average GPIO:GP OUT2 is OFF after power off/on
PF9100203405 3 - Average Door cmd are sent twice,
PF9100203421 3 - Average STM trip counter: terminal command set wrong
trip counter value
PF9100200841 3 - Average several problems during LOP TEACHING (Re-
Submitted)
PF9100203417 4 - Minor STM trip counter: wrong upperbound definition
Improvement
-------------
PF9100203280 2 - Major Improve requestInputStates in Landing Panels
PF9100203473 2 - Major Landing Optimizations at startup
PF9100203519 3 - Average BIOBUS Startup in UI
PF9100164756 3 - Average Automatic HW Evacuation, set LVC output lamp,
switch OFF car light
PF9100203124 5 - Enhancement Improve Service Earthquake Japan
PF9100203484 5 - Enhancement P3108.1 EAQ(JP) [JEB, LMH] Earthquake
Operation - Imporvements for phase II - SW
Rejected:
-------------
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
N/A
- New functionality: -
----------------------
PF9100203114 3 - Average Drive: (INI 6) Use Case: Set system date and time to
implement
PF9100202187 5 - Enhancement Restricted Access (Card Reader) (ZB2 JPN) - SW
PF9100202100 5 - Enhancement I1411.1 GPIO Generic purpose I/O - SW
PF9100202179 5 - Enhancement P4721.1 VACA - Adaptive Voice Announcement
Sequence - SW
Bugfix Corrected:
-------------
PF9100203199 2 - Major P3108.1 EAQ(JP) [JEB, LMH] Earthquake Operation - DT-
O and DT-O backlight are in
PF9100203006 2 - Major Partition door: a door close announced is played when
the door is being opened
PF9100203228 3 - Average CLCRecalibration doesn't stop
PF9100202877 3 - Average P6101.6 PBEA(JP)[DOB] - Wrong Floor announcement
during Automatic Evacuation
PF9100203005 3 - Average Gong direction lamps: GA_D and GA_U are always on
Improvement
-------------
PF9100203221 2 - Major CLC should be also stopped when the door is locked
PF9100202386 6 - not applicable Codebase improvement: fix all comp
warnings
Resolved without SW changes:
------------------
Rejected:
-------------
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.92.20
--------
Delivered (d/m/y):16/05/2012
PC/NT : S00x.exe, 19403264 bytes
N/A
- New functionality: -
----------------------
PF9100202104 5 - Enhancement P4207.1 EUNEF - Notify unavailability of
elevator for safety reason - SW
PF9100202087 5 - Enhancement M1301.2 CPCOR [OD] - Correction Travel to
Next Floor [Door open after correction] - SW
Bugfix Corrected:
-------------
PF9100202909 2 - Major SHBT - problem during attivation of Photocell
to V9.92
PF9100202960 2 - Major COP5B programming is being deleted at each
controller power-up or reset
PF9100202996 2 - Major DTH-O is not working
PF9100202999 3 - Average Configuration: Anti-nuisance 1 and 3 cannot be
removed using the terminal commands
PF9100201315 3 - Average deactivation of BR1 JP door state isn't correct
PF9100202903 3 - Average Landing Accuracy: wrong correction is used in
case of having blind floors
PF9100164742 4 - Minor Fulload defect with anti nuisance AN3
PF9100202514 4 - Minor Duplex param editable
PF9100203109 4 - Minor Show OEM Status - Set visibility of <Remaining
trips to activation>
PF9100180617 4 - Minor CC DTO in RV2 with 2 side
Improvement
-------------
PF9100203137 2 - Major Reduce Can bus traffic between COPs and
controller
PF9100202926 3 - Average KID/CDD: Chang default values of parameters -
SW
PF9100202670 4 - Minor Eliminate GNU compiler warnings (internal SW
change)
PF9100202649 5 - Enhancement Provide Public OEM state from one
location (internal SW change)
Rejected:
-------------
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.92.19
--------
Delivered (d/m/y):03/05/2012
PC/NT : S00x.exe, 19407872 bytes
N/A
- New functionality: -
----------------------
PF9100202006 3 - Average combo floor call adapting door timing
PF9100202092 5 - Enhancement P4503.4 AN [CDIR] - Anti-Nuisance [Cancel
call at change of direction] - SW
PF9100202096 5 - Enhancement P1302.1 DS - Destination Shuttle - SW
PF9100202108 5 - Enhancement P4412.1 BDOX Push Button Door Open
Extended - SW
PF9100201846 5 - Enhancement P4501.4 DCN (JP) [IND,MOV,MAN] Door Close
Nudging (Final timer) - SW
PF9100201883 5 - Enhancement P2208.2 DTA[GLOB] Adaptive Door Timing -
DTO buffering - SW
PF9100202260 5 - Enhancement P4302.1 CLE Emergency Light in Car - SW
PF9100201869 5 - Enhancement P4501.5 DCN - DTO enabled for JP market -
SW
PF9100202371 5 - Enhancement P2208.2 DTA[GLOB] Adaptive Door Timing -
Handicapped LOP Acknowledge - SW
PF9100202175 5 - Enhancement P4719.1 VAA Verbal announcement for
assistance - SW
PF9100201172 6 - not applicable P4410.1 PD [] Partition Door, Phase
II - SW
PF9100202810 6 - not applicable CMR: AAT full brake test adaption
to 2.5 m/s, temporary
Bugfix Corrected:
-------------
PF9100202631 1 - Critical Service, getEmergencyDoorSide, should be
supported the case when the current lev
PF9100202908 2 - Major ZZ3 DTO does not work with pending calls to
V9.92
PF9100202759 3 - Average CMR: Trip counter inconsistency error
PF9100180628 4 - Minor ZZ2 mode:in RV2 mode with DT-S close both door
PF9100201324 4 - Minor Travel Direction Indicator doesn't switched off
on Second Cop.
Improvement
-------------
PF9100200081 3 - Average Two Doors Object 3 (Re-Submitted)
PF9100202650 5 - Enhancement Cleanup single door object
PF9100202892 5 - Enhancement Cleanup OldDoorMode
PF9100201310 5 - Enhancement COPPI: CF13 update
PF9100202764 6 - not applicable Add "READ_PSHAFT_EE" terminal
command
PF9100202671 6 - not applicable CMR: Redundant trip counter and STM
monitoring (Step 1) - Maximum value check -
Rejected:
-------------
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.91.18
--------
Delivered (d/m/y):17/04/2012
PC/NT : S00x.exe, 20208128 bytes
N/A
- New functionality: -
----------------------
PF9100202783 2 - Major SW Bionic - UCM request safety chain shutdown
in case of persistant fatal - Ste
PF9100202677 3 - Average Handle multiple DTO
PF9100202799 5 - Enhancement Automatic Car Positioning for Short Pit
to V9.91
PF9100202738 6 - not applicable SW (CMR ph2) - Drive parameters
menu entry for PM motor not yet implemented
Bugfix Corrected:
-------------
PF9100202742 2 - Major Erratic KTS monitoring
PF9100202804 2 - Major Correction possible blocked do to feedback not
evaluated to V9.91
PF9100202753 2 - Major AAT 15 is locked wneh CLC is not overbridged
PF9100201959 2 - Major Attendant Service - Resevation on Attendant
Service Box is not working
PF9100202531 3 - Average zz3 mode:after learning wrong configuration of
CF 30
PF9100202775 3 - Average BR 3 BE :SUMC is always active after
deactivation of smoke
Improvement
-------------
PF9100202686 3 - Average Improve ISPT monitoring
Rejected:
-------------
Known limitations:
------------------
Notes:
------
New Bootloader V2.1 due to OEM is required to update the application
Please clear EEPROM before doing any upgrate to this version.
V9.91.17
--------
Delivered (d/m/y):28/03/2012
PC/NT : S00x.exe, 20204032 bytes
N/A
- New functionality: -
----------------------
PF9100202390 2 - Major SW Bionic - UCM request safety chain
shutdown in case of persistant fatal - Ste
PF9100202032 6 - not applicable Support 1K Sim Card
PF9100179351 6 - not applicable SW (CMR ph2) : EEPROM conversion 35
stops
PF9100202410 6 - not applicable M2233.1 MSSCOI - Monitor Static
Safety Circuit Open at ISPT - SW
Bugfix Corrected:
-------------
PF9100202596 1 - Critical Doors are not opened for an indefinite
time
PF9100202613 1 - Critical zz2 mode: overload on one side generate
door open on protected floor (PF91002025
PF9100202365 2 - Major RPHT disable after fitter leaves configuration
PF9100202418 2 - Major carlightt sensor isn't detect
PF9100202394 3 - Average br3KR: after activation of FF door closing
automatically to V9.91
PF9100202474 3 - Average Implement the
S_NO_OPERATION_DUE_TO_INVALID_LOAD_CONFIGURATION status to V9.91
PF9100202464 3 - Average With selective door mask send too early while
the second is nudging
PF9100202534 4 - Minor LAB is OFF during learning and CHB for 9.91
PF9100202207 4 - Minor BCD: Car descent monitor must be disabled on
Bionic 5 installation to V9.91
Improvement
-------------
PF9100202395 3 - Average BR3 India update: door close behavior changes -
SW to V9.91
PF9100202619 3 - Average RMCC call to Controller - transmit OEM status
over Real time channel to V9.91
PF9100202618 5 - Enhancement Change extra data info for OEM status
messages to V9.91
PF9100202550 6 - not applicable CMR: Redundant trip counter and STM
monitoring (Step 1)
Rejected:
-------------
Known limitations:
------------------
Notes:
------
New Bootloader V2.1 due to OEM is required to update the application
Please clear EEPROM before doing any upgrate to this version.
V9.91.16
--------
Delivered (d/m/y):19/03/2012
PC/NT : S00x.exe, 20148736 bytes
N/A
- New functionality: -
----------------------
PF9100202041 1 - Critical OEM: reduce possibility to change the OEM
Setting via external tools to V9.9
PF9100201918 1 - Critical I6106.1 OEM Amendment - Classification of
Error Code - SW to V9.91
PF9100202213 2 - Major SW - UCM request safety chain shutdown in case
of persistant fatal - part 2 to V
PF9100201919 3 - Average Floor on Fire, EBR1 for all countries analisys
to V9.91
PF9100202217 6 - not applicable CMR: CCU-COP integration support
new SCCI2 and SCMI - SW
PF9100202287 6 - not applicable Closed Loop: Simcard drive
parameters ACVF=5 should be supported for the Vacon d
Bugfix Corrected:
-------------
PF9100201950 1 - Critical ETM: Wrong header in the data sent by
controller to RMCC. to V9.9
PF9100202142 2 - Major LOP teaching is not working
PF9100202201 2 - Major I6106.1 <OEMPAL>Service Access Level Handling
is not correct to V9.91
PF9100202202 2 - Major <Simcard> If simcard content a data option that
Sw does not support or recognise
PF9100201904 2 - Major ZZ3 - car blocked above the interlocked floors
to V9.91
PF9100201905 2 - Major ZZ3: both doors open at DTO at landing to V9.91
PF9100202389 2 - Major 9.82.24 - Door timers behavior changed (?!) to
V9.91
PF9100201921 2 - Major LI service:attivation on floor with TWO SIDE
both doors open to V9.91
PF9100201906 3 - Average BR3 BE : Smoke Detector doesn't work fine. to
V9.91
PF9100201907 3 - Average overload in DE lop buttons switch OFF to V9.91
PF9100201908 3 - Average BR3 BE:smoke detector active both doors open in
interlocked door mode to V9.91
PF9100202172 3 - Average High Torque: Press DREC button reset High
Torque mode
PF9100201297 3 - Average RPHT-M doesn't works with SELECTIVE DOOR (Re-
Submitted) (Re-Submitted)
PF9100202203 3 - Average Automatic Evacuation: Many Diagnostic Calls are
triggered for BIOBUS monitoring
PF9100202206 3 - Average on BLIND FLOOR ,with SDIC RESET door opens to
V9.91
PF9100201826 3 - Average carlight remains always ON after learning
PF9100201140 3 - Average ZZ0 :different behaviour between B5 and bX
during reversing (KSKB-RPHT)
PF9100201922 3 - Average resubmitted:motorovertemp.:in ZZ3 both doors
opens to V9.91
PF9100201923 3 - Average wrong behaviour when erase a node on one SIDE
to V9.91
Improvement
-------------
PF9100202042 1 - Critical CLC support improvement to V9.9
PF9100202209 2 - Major OEM: Remote connection from Schindler CC
doens't open the menu's to V9.91
PF9100201914 2 - Major ETM: UKC phone number must be changed to
08081688081 (CIR: Nr. SCH2-110110) to V9.91
PF9100201915 3 - Average OEM: Close Backdoor for getting Terminal-VT100
back on XTELE with no simcard-rig
PF9100202210 3 - Average Advanced log: improve recall command and dump
to V9.91
PF9100202212 5 - Enhancement OEM status command to V9.91
PF9100201916 5 - Enhancement Read out the SCPU Bootloader version to
V9.91
PF9100201958 5 - Enhancement Consider interlocked door type for CF30
and CF02
PF9100201854 6 - not applicable CMR: Redundant trip counter and STM
monitoring (Step 1) - SW
Rejected:
-------------
Known limitations:
------------------
Notes:
------
New Bootloader V2.1 due to OEM is required to update the application
Please clear EEPROM before doing any upgrate to this version.
V9.91.15
--------
Delivered (d/m/y):01/03/2012
PC/NT : S00x.exe, 7843840 bytes
N/A
- New functionality: -
----------------------
PF9100181790 3 - Average Managing the KNET for short head and short-pit
PF9100201920 5 - Enhancement TestCommand to enter error in error
history to V9.91
Bugfix Corrected:
-------------
PF9100201407 2 - Major Set current level problem with Short Synchro
and Blind floors
PF9100081526 2 - Major Fix Random Key Problem OEM
PF9100202050 3 - Average Correct timeout for OEMT and SETT for V9.91
PF9100201664 3 - Average KTTJ, mem leak
PF9100201909 3 - Average SPECI:problem with DTO in ZZ3 or ZZ2 mode to
V9.91
PF9100201911 3 - Average OEM: Missing 5min timeout when OEMT or SETT is
disconnected to V9.91
PF9100201913 3 - Average GS param visible without SIM optionn to V9.91
PF9100181578 4 - Minor TSD option unknown with shaft learned (?)
PF9100201924 5 - Enhancement OEM - SPECI errorlog not available if no
errors - Controller side to V9.91
Improvement
-------------
PF9100201929 6 - not applicable I5101.2 LUET [BUZZ] limit the scope
of function activation - SW
Rejected:
-------------
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.91.14
--------
Delivered (d/m/y):09/02/2012
PC/NT : S00x.exe, 7828992 bytes
N/A
- New functionality: -
----------------------
PF9100201336 1 - Critical OEM: downgrade to 9.74 is feasible,
change for 9.9
PF9100200836 3 - Average SW (CMR ph2) - create a beep in the controler
if LUET is active in case of manua
PF9100201380 6 - not applicable SW (CMR ph2) - Support of 35 LOPs
each side
PF9100179350 6 - not applicable SW (CMR ph2) - Allow for 35 stops
PF9100201555 6 - not applicable SW (CMR ph2) - Allow for 35 stops
(II)
Bugfix Corrected:
-------------
PF9100201538 1 - Critical Pre-opening does not work in parallel
mode
PF9100201549 2 - Major With two SCOPMXB the second COP does not work
PF9100201256 2 - Major CF 6 PA24 is disable
PF9100201166 2 - Major Fire Service: exiting, selective doors
PF9100201167 2 - Major KS, Selective Door Type, Twin Call: door sides
are not opened together
PF9100201190 3 - Average CMR: Implement a new high torque command to
release safety gear
PF9100201410 3 - Average Doubled door state messages on VCA
PF9100201344 3 - Average SW (CMR Ph1) Landing accuracy - new parameter
ranges and defaults
PF9100201206 3 - Average EB JP:after start up DEACTIVATION of EB is
wrong (Re-Submitted) (Re-Submitted)
Improvement
-------------
PF9100201174 1 - Critical Logging performance improvement - Part II
PF9100201181 6 - not applicable Commodity mid-rise: call simulation
(30), support all available levels and rando
PF9100201371 6 - not applicable CMR: Increased Inspection Speed -
SW
Rejected:
-------------
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.9.14
--------
Delivered (d/m/y):20/02/2012
PC/NT : S00x.exe, 7864320 bytes
COLDFIRE (SCIC 6):
SCC6_990.BIN checksum: 0x9d179df
SCC6_CHK.ABS checksum: 0x16a3a9d0
N/A
- New functionality: -
----------------------
PF9100201601 2 - Major P3108.1 EAQ(JP) [JEB, LMH] KEBVL does not work
propely
Bugfix Corrected:
-------------
PF9100201637 1 - Critical P2208.2 DTA[GLOB] Adaptive Door Timing -
2 Combo CarCall are not working correct
PF9100201670 1 - Critical P3108.1 EAQ(JP) [JEB, LMH] Earthquake
Operation - Activation of KEBH must stop t
PF9100201707 2 - Major CF 6 PA24 is disable (copy to
schaffst_prjS00x_0009_V9_9_JapanC6)
PF9100201619 3 - Average After the EB is deactivated Door Closing
announcement MUST not come
PF9100201668 3 - Average P3220.1 FR(JP)[RG] Fire emergency recall type 1
- Wrong Switching of the Car Lig
PF9100201669 3 - Average P3220.1 FR(JP)[RG] Fire emergency recall type 1
- During Fire the FAN must be switched OFF - SW
Improvement
-------------
PF9100201630 1 - Critical P3108.1 EAQ(JP) [JEB, LMH] Earthquake
Operation - Improve Moving algorithm - SW
PF9100201634 2 - Major P2208.2 DTA[GLOB] Adaptive Door Timing -
Acknowledge Improvement - SW
PF9100201597 3 - Average P6101.6 PBEA(JP)[DOB] Dedicated door open time
for the evacuation conclusion - S
Rejected:
-------------
Known limitations:
------------------
Notes:
------
Clear EEPROM before doing any upgrate to this version.
V9.9.13
--------
Delivered (d/m/y):18/01/2012
PC/NT : S00x.exe, 7859200 bytes
N/A
- New functionality: -
----------------------
PF9100201230 1 - Critical P2208.2 DTA[GLOB] Adaptive Door Timing -
Remove menu visibility constraints
PF9100201223 3 - Average To support HW ID of Vacon NXP3.
Bugfix Corrected:
-------------
PF9100201200 2 - Major COPPI: <Teaching landing>: selectiong the floor
on COPPI is not accepted and car
PF9100201201 2 - Major <COPH>: Car call for floor level higher than 8
is not working
PF9100201199 2 - Major COPPI: Travel indication are not working
PF9100201160 3 - Average <Door error handling>After 3 times the KSKB
door reverses, the door open time ou
Improvement
-------------
PF9100201221 2 - Major Relevelling: Wrong behavior in case of Siganl
PHUET bridged, when preopening is disabled by CF8 PA7 - SW
Rejected:
-------------
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.9.12
--------
Delivered (d/m/y):12/01/2012
PC/NT : S00x.exe, 7859200 bytes
N/A
- New functionality: -
----------------------
PF9100201036 1 - Critical PXXXX.X Rescue Travel using Trunk Room,
Phase I - SW
PF9100081562 5 - Enhancement EEPROM conversion from V9.82.24 to
V9.9.11
Bugfix Corrected:
-------------
PF9100201061 2 - Major Fire service loops sending DOOR commands.
PF9100200995 2 - Major ZZ3 both doors open at DTO at landing for V9.9
PF9100201123 2 - Major Japanese feature: the emergency switching off
light should be based on the selec
PF9100200969 3 - Average COP5-1N 25 AP with SW V 9.9.10 doesn't works.
PF9100200971 3 - Average SECOND_HANDICAPED_SCOP with SW V 9.9.10 Doesn't
works.
PF9100201158 3 - Average SAFE EXIT: carlight switch OFF during NS21
PF9100201162 3 - Average safe exit: carlight is OFF during evacuation
with BR1 JP
PF9100201062 3 - Average Door remains open after configuration
PF9100201051 3 - Average OUT of GROUP:after overload elevator doesn't
detect OUT OF GROUP (Re-Submitted)
PF9100201037 4 - Minor COP destination is not correct updated in of
selective and interlocked doors
PF9100200981 4 - Minor COP destination is not correct updated in of
selective and interlocked doors
PF9100201126 4 - Minor after activation of KLS U/D elevator switch OFF
all "ack"
Improvement
-------------
PF9100201075 1 - Critical Logging performance improvement
PF9100201018 2 - Major Common door state in controller SW
Rejected:
-------------
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.9.11
--------
Delivered (d/m/y):21/12/2011
PC/NT : S00x.exe, 7842816 bytes
N/A
- New functionality: -
----------------------
PF9100200747 3 - Average EB JP:during EB arrival gong and travel
indicator aren't deactivated
PF9100200930 6 - not applicable SW: Project FC-EC integration, new
VF device to be supported
Bugfix Corrected:
-------------
PF9100200923 1 - Critical serviceKLSUD: don't exit for levels with
two available sides
PF9100200936 2 - Major at start up with EB JP active elevator execute
syncro
PF9100200962 2 - Major reset in FullLoad mode: is asserting
PF9100179969 2 - Major elevator serves CC on SIDE1 but DTO on SIDE2
does not work
PF9100200967 3 - Average SafeCast assert in RaDatCol.cpp (Re-Submitted)
PF9100200939 3 - Average LVC:some problem with carlight during
activation of JAB
PF9100164613 3 - Average EB JP:after deactivation of KEBL or KEBH and
start up the service is not persist
PF9100200986 3 - Average serviceConfiguration: blocking doors during
exiting
PF9100200914 3 - Average Finaltimer does not work after door reversing
(RPHT, KSKB)
Improvement
-------------
Rejected:
-------------
Known limitations:
------------------
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.9.10
--------
Delivered (d/m/y):15/12/2011
PC/NT : S00x.exe, 7840256 bytes
N/A
- New functionality: -
----------------------
PF9100181791 3 - Average REACH: Implement a new high torque command to
release safety gear
PF9100200786 6 - not applicable SW (CMR ph2) - Drive parameters not
yet implemented in REACH (Re-Submitted)
PF9100200767 6 - not applicable SW: Project FC-EC integration, new
VF device to be supported
Bugfix Corrected:
-------------
PF9100200778 1 - Critical Elevator travelling in OVERLOAD for V9.9
PF9100200718 2 - Major EB JP: contact of earthquake is NORMALLY CLOSE
not OPEN
PF9100180156 2 - Major elevator in FATAL but after few seconds LVC
switch OFF
PF9100180083 2 - Major elevator doesn't detect 2 COPH
PF9100180040 2 - Major elevator doesn't make an evacuation if activate
JAB after power OFF/ON
PF9100200734 2 - Major EB JP:after start up deactivation of KEB VL is
impossible
PF9100180115 2 - Major policyDE : elevator in "LPC" mode wake up but
doesn't serves floor call
PF9100200775 2 - Major Emergency Stop generate Assert with SW V 9.9.08
PF9100125759 3 - Average at evacuation floor wrong behaviour of doors
PF9100200885 3 - Average EB JP:carlight switch on after door reopens
with RPHT or KSKB
PF9100200764 3 - Average P4301.4 CLC:carlight switch OFF/ON after
evacuation of JAB (Re-Submitted)
PF9100200849 3 - Average P4301.4 CLC:carlight switch OFF/ON after
evacuation of JAB
PF9100200852 3 - Average after start up without SIM CARD elevator is
blocked
PF9100200871 3 - Average ZZ3 door closes in overload
PF9100182003 3 - Average Accessing Menu 306 without SIMCard param
PF9100181842 3 - Average ZBC2:call on protect floor are disable but
"ACK" remains ON
PF9100180188 3 - Average Assertion after Power Off / On in Out Of
Service.
PF9100200724 3 - Average assertion during deactivation of EB JP on one
side
PF9100181795 3 - Average System blocked during test- contactor
supervsion
PF9100182106 3 - Average zz3 - recovery-problem of door that was not
operated at last trip
PF9100181038 3 - Average OUT of GROUP:after overload elevator doesn't
detect OUT OF GROUP (Re-Submitted)
PF9100049943 4 - Minor HMI shows two doors on system with only one
door
PF9100200875 4 - Minor Resolving of integration problems
PF9100200732 4 - Minor Parking 4 with SW 9.9.08 : Doors never Open.
PF9100179966 4 - Minor LOP DTO not reopens immediately door
Improvement
-------------
PF9100199171 2 - Major Wrong code is sent with message for "Controller
Configuration Changed"
PF9100200785 6 - not applicable SW:FCParamConfigurator improve
logging
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
Please test also fixes of the release V9.8.15.
Please clear EEPROM before doing any upgrate to this version.
V9.9.9
--------
Delivered (d/m/y):1/12/2011
PC/NT : S00x.exe, 7828480 bytes
COLDFIRE (SCIC 6):
SCC6_990.BIN checksum: 0x9c83bae
SCC6_CHK.ABS checksum: 0x16b2ca28
N/A
- New functionality: -
----------------------
PF9100180179 3 - Average Support COPPI 2
PF9100081552 5 - Enhancement CF05 new PA for COP PI
PF9100180138 6 - not applicable SW: Project FC-EC integration, new
VF device to be supported (changed requiremen
PF9100179371 6 - not applicable SW (CMR ph2) - Drive parameters not
yet implemented in REACH
Bugfix Corrected:
-------------
PF9100180092 1 - Critical BX-HY : at Startup Lop call not possible.
PF9100180143 2 - Major Fire Activation with SW 9.9.08 generate loop of
Assert.
PF9100180144 2 - Major Emergency Stop generate Assert with SW V 9.9.08
PF9100180201 2 - Major LOP - setupFloorDesignations is looped for more
than 15 floors
PF9100180193 2 - Major Parking service - door timer change should
consider the side
PF9100180152 3 - Average P4301.4 CLC:carlight switch OFF/ON after
evacuation of JAB
PF9100180192 3 - Average Configuration service - consider available door
sides
PF9100180061 3 - Average NO CAR_LOAD_RQST after CLC calibration
PF9100181967 3 - Average RPHT-M doesn't works with SELECTIVE DOOR (Re-
Submitted)
Improvement
-------------
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
Please test also fixes of the release V9.8.15.
Please clear EEPROM before doing any upgrate to this version.
V9.9.8
--------
Delivered (d/m/y):17/11/2011
PC/NT : S00x.exe, 7820800 bytes
N/A
- New functionality: -
----------------------
PF9100179063 1 - Critical P3108.1 EAQ(JP) [JEB, LMH] Earthquake
Operation - SW
PF9100180046 1 - Critical M2629.1 MTLO Monitor terminal landing
overrun - amendement - SW
PF9100179636 2 - Major SW - UCM request safety chain shutdown in case
of persistant fatal
PF9100179840 3 - Average P2208.2 DTA[GLOB] Adaptive Door Timing -
Overlay integration - SW
PF9100180076 3 - Average Landing Accuracy: teminal command for showing
the current corrective data for ev
PF9100180077 6 - not applicable SW: Project FC-EC integration, new
VF device to be supported (changed requiremen
PF9100180058 6 - not applicable Phase 2: SW (CMR Ph1) Landing
accuracy - new algorithm for accuracy learning
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100180019 1 - Critical M2629.1 MTLO: Elevator ignore KLS-U or
KLS-D activation (Re-Submitted)
PF9100180023 1 - Critical P4718.1 ILVC Leave car indication not
works (Re-Submitted)
PF9100180026 2 - Major P4301.4 CLC: Car light do not switch OFF when
evacuation is done (Re-Submitted)
PF9100126726 2 - Major Hydraulic Drive Overltemp: in case of Recall or
Inspection Elevator do not retur
PF9100181813 2 - Major shift position of FLAG on BLIND FLOOR: door
open on BLIND
PF9100179788 2 - Major Teaching Landing with COPH: Floor selection is
not working when above 15th floor
PF9100180005 2 - Major Out Of Service Activation with SW V 9.9.07
generate loop of assert.
PF9100180009 3 - Average CLC Calibration is Not Possible with CF 97 .
PF9100081548 3 - Average SafeCast assert in RaDatCol.cpp
PF9100199128 3 - Average After failed autoconfig calls ETM does not
reset the prefix
PF9100180712 3 - Average Graceful Fatal Error with BX-FA doesn't work.
PF9100182031 3 - Average Watchdog reset on 9.74.30: CLFCDrv.cpp
PF9100182096 3 - Average CLC NO FREQUENCY recovery
PF9100181464 4 - Minor Wrong Behaviour Door Reversing Car Call
Canceling. (Re-Submitted)
PF9100179782 2 - Major BCD Trigger: Car blocking detection does not
consider frequency variation due to
PF9100179774 3 - Average policy PI - car call ack not canceled to V9.9
PF9100179918 3 - Average Wrong uint32 handling in half brake AAT
Improvement
-------------
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
Please test also fixes of the release V9.8.15.
Please clear EEPROM before doing any upgrate to this version.
V9.9.7
--------
Delivered (d/m/y):03/11/2011
PC/NT : S00x.exe, 7812096 bytes
N/A
- New functionality: -
----------------------
PF9100179884 1 - Critical M2629.1 MTLO Monitor terminal landing
overrun (team cross validation feedback)
PF9100179078 1 - Critical P4717.1 IBD [Open;Close] Door button
presence indication - SW
PF9100179088 1 - Critical P4718.1 ILVC Leave car indication - SW
PF9100179092 1 - Critical M2629.1 MTLO Monitor terminal landing
overrun - SW
PF9100179111 1 - Critical P2208.2 DTA[GLOB] Adaptive Door Timing -
SW
PF9100179162 1 - Critical P4301.4 CLC[AUTO, EVAC ] Light control in
the Car with switch off after evacuati
PF9100179414 3 - Average Landing Accuracy: teminal command for showing
the current corrective data for ev
PF9100179802 3 - Average To support the identification and error
handling of the VACON PF1 inverter to V9
PF9100179300 6 - not applicable SW (CMR Ph1) Landing accuracy - new
algorithm for accuracy learning
PF9100181694 6 - not applicable SW: Project FC-EC integration, new
VF device to be supported
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100179791 1 - Critical UCM: blocked after
E_DOOR_SUET_ERROR2_OVERBRIDGING_LOST to V9.9
PF9100179799 2 - Major LPC : Elevator after wakeup goes in Persistent
Fatal Error. to V9.9
PF9100179800 2 - Major <BR4 HK> After Syncronization Trip the DTO is
not Working as aspected to V9.9
PF9100179872 2 - Major Assert: Calibration with Reference Load (40 -
CF99)
PF9100179787 2 - Major KB / KB1 Error generate Assertion. to V9.9
PF9100179789 2 - Major Preleveling with Blind Floor produce many
problem. to V9.9
PF9100179849 3 - Average Parallel doors, Side 1 and 2 not available for
9.9
PF9100180476 3 - Average after fatal for door error handling both door
opens in interlocked mode
PF9100164518 3 - Average BR4 HK: door remains open after cf31 pa6
elapses
PF9100179784 3 - Average After return from Service to Normal Mode the
Floor call acknowledge lamps are no
PF9100179786 3 - Average Menu visualization and configuration should be
the same as for V9.73 to V9.9
PF9100179776 3 - Average CF31 Fire service parametrization: SW update to
V9.9
PF9100179780 3 - Average during configuration elevator make drifting
parking - SW to V9.9
PF9100179794 3 - Average 9.8.14: Assertion 0x30214310 to V9.9
PF9100179797 3 - Average elevator detcts OVERLOAD and "ACK" on COP and
LOP switch OFF to V9.9
PF9100179798 3 - Average SPECI: elevator make an assertion before starts
lop teaching to V9.9
PF9100126123 4 - Minor LAB is OFF during learning trip
PF9100182033 4 - Minor TrafficController carcall canceling - Cast
mismatch
PF9100181989 4 - Minor Resolve integration problems due to merge
Improvement
-------------
PF9100179769 1 - Critical Set the default value of Low Power
Consumption functionality to 0 - SW to V9.9
PF9100179767 3 - Average LPC mode - SDIC integration to V9.9
PF9100179768 3 - Average LPC mode - IO Handler SDIC integration to V9.9
PF9100179387 3 - Average SW internal: eliminate the comp warnings
PF9100179783 3 - Average LPC mode:clc calibration every 12 min to V9.9
PF9100164543 4 - Minor New HWID for SDIC42.QC --> Changes Bionic SW
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please test also fixes of the release V9.8.15.
Please clear EEPROM before doing any upgrate to this version.
V9.9.6
--------
Delivered (d/m/y):01/09/2011
PC/NT : S00x.exe, 7746560 bytes
N/A
- New functionality: -
----------------------
PF9100182005 3 - Average P3108.1 EAQ(JP) [JEB, LMH] Earthquake Operation
- SW
PF9100081519 5 - Enhancement Conclude IO Diagnostics for Speci and HMI
PF9100179221 5 - Enhancement COPPI support
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100164483 2 - Major To improve safety chain error handling and
recovery: 3500 warning in 15 hours
PF9100181921 2 - Major After Preleveling Elevator is Blocked.
PF9100179239 3 - Average SAS:impossible to conf. SAS with SW V 9.9.05
PF9100181615 3 - Average DT-S doesn't works after door reversing ( KSKB
or RPHT ).
PF9100181854 3 - Average after LOP teaching COP remains diable
PF9100164484 3 - Average BR4 HK-C:wrong behaviour after power off/on in
FF
PF9100179158 3 - Average Floor designation for Asia Pacific with SW V
9.9.05 is not possible.
PF9100081518 3 - Average Menu 110 on SPECI: Calls not accepted, no
feedback to SPECI
PF9100164463 3 - Average Evacuation on BX-OL with SEMP: If the power
return during evacuation trip, the elevator remain blocked in Drive Error.
PF9100181839 4 - Minor Advance alarm filter doesn't work fine on
second Cop.
Improvement
-------------
PF9100179169 3 - Average Two Doors Object 3
PF9100164473 5 - Enhancement SCIC: Add placeholder for CAN-interface
messages used in CMG
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please test also fixes of the release V9.8.15.
Please clear EEPROM before doing any upgrate to this version.
V9.9.5
--------
Delivered (d/m/y):08/08/2011
PC/NT : S00x.exe, 7726080 bytes
N/A
- New functionality: -
----------------------
PF9100181860 3 - Average SW OEM: Inform RMCC about the changed state of
OEM policy V9.9
PF9100181804 3 - Average SW OEM: Write OEM policy state in SIM card V9.9
PF9100181899 3 - Average SW OEM: Update menu 109 on V9.9
PF9100181900 3 - Average SW OEM: At startup, check and in case update to
higher level on V9.9
PF9100181895 3 - Average SW OEM: Implement the enable and disable
command on V9.9
PF9100181887 3 - Average Error in converting FC simcard option from
V9.62 to 9.9
PF9100181901 5 - Enhancement OEM: Integrate new functionalities on
V9.9
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100181884 1 - Critical SW9.8.14 assertion once pressed '-' on
V9.9
PF9100181942 1 - Critical Learning trip: re-calculate flag edges in
case of pulley diameter change on V9.9
PF9100181941 2 - Major OEM: problem empty key for disable command on
V9.9
PF9100081513 2 - Major LED should works as well when OEM policy is
active
PF9100181961 3 - Average PI policy :wrong behaviour of door during
reversing (open/close two times) on V
PF9100181859 3 - Average FDS: The ETM is not sending the cumulative trip
time V9.9
PF9100181943 3 - Average EEPROM conversion from old to V9.81, implement
on V9.9
PF9100181885 3 - Average AAT of UCM :HMI blocked if conf. floor isn't on
LDU floor on V9.9
PF9100181886 3 - Average Low Power Consumption : doesn't work fine in
Duplex. on V9.9
PF9100181890 3 - Average overload disable drifting parking on V9.9
PF9100181891 3 - Average Menu 320 on SPECI with fix values
PF9100181892 3 - Average CF97-99 activated by SPECI goes on COP and not
on HMI on V9.9
PF9100181893 3 - Average CF15 on SPECI is not working on V9.9
PF9100181894 3 - Average Parameter after SPECI connection startup not
send correct on V9.9
PF9100181815 3 - Average CF21 PA82 on SPECI is wrong TYPE on V9.9
PF9100181818 3 - Average OEM: CF40/41 with SPECI, some times leaving the
menu is not aligned
PF9100181775 3 - Average RESUBMITTED: policy PI - landing call not ack
when landing on V9.9
PF9100181780 4 - Minor Cop Domino Configuration Doesn't works fine
with SW V 9.9.02.
Improvement
-------------
PF9100081514 1 - Critical ETMA-Code non compliance due to terminal
activation
PF9100181888 3 - Average REACH: use of the parameter to set overload
threshold below 110% on V9.9
PF9100081511 3 - Average The fitter should be able to activate OEM using
the OEM Enabler
PF9100178838 3 - Average Two Doors Object 2
PF9100178805 3 - Average New COP Package Cleanup 3
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please test also fixes of the release V9.8.15.
Please clear EEPROM before doing any upgrate to this version.
V9.9.4
--------
Delivered (d/m/y):28/06/2011
PC/NT : S00x.exe, 7703040 bytes
N/A
- New functionality: -
----------------------
PF9100178640 5 - Enhancement Add the new manual doors to manual door
list
PF9100178657 5 - Enhancement Two Doors Object
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100164446 3 - Average ZBCE: after activate JSPS ,COP5 shows "Er"
PF9100181743 3 - Average SW: PROCITS:CIR: Nr. SCH2-110004
PF9100181853 3 - Average BR2-UKC EN81-72 change the door closing
condition on V9.9
Improvement
-------------
PF9100178762 5 - Enhancement New COP Package Cleanup 2
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please test also fixes of the release V9.8.15.
Please clear EEPROM before doing any upgrate to this version.
V9.9.3
--------
Delivered (d/m/y):01/06/2011
PC/NT : S00x.exe, 7860736 bytes
COLDFIRE (SCIC 6):
SCC6_990.BIN checksum: 0x9c8abde
SCC6_CHK.ABS checksum: 0x16ba4f3c
N/A
- New functionality: -
----------------------
PF9100181786 3 - Average New door types: QKS2 and AT40 (Main Application
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100164407 1 - Critical Deactivation of SHBT via car call not
working
PF9100164414 2 - Major overload during NS21 people TRAPPED
(unduplicated)
PF9100181753 2 - Major System blocked with a wrong door cmd on V9.9
PF9100181817 3 - Average IMPORTANT:Correct definition of servitel
protocol messages on V9.9
PF9100181820 3 - Average Change of destination not accepted by
activation of fire service on V9.9
PF9100164415 3 - Average ZBCE:with cf41 pa99=3 CC is enable
Improvement
-------------
PF9100178288 3 - Average New COP Package Cleanup
PF9100164413 3 - Average SEMBX and SMICE32 for Open Loop and Evacuation
improvements
PF9100181757 3 - Average SW: Telemonitoring blocked by failing clock -->
autoconf impossible on V9.9
PF9100178367 5 - Enhancement Two Doors Object: generic SDIC msg
PF9100178476 5 - Enhancement Two Doors Object: Recovery
PF9100164396 6 - not applicable Two Doors Objects Implementation
and Improvements 1st
PF9100164406 6 - not applicable Two Doors Objects Implementation
and Improvements 2nd
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please test also fixes of the release V9.8.15.
Please clear EEPROM before doing any upgrate to this version.
V9.9.2
--------
Delivered (d/m/y):28/04/2011
PC/NT : S00x.exe, 7850496 bytes
N/A
- New functionality: -
----------------------
PF9100181248 3 - Average SAIO2 support IO handler
PF9100164353 3 - Average BR1JAP Fire Service for Japan
PF9100081487 5 - Enhancement IO support for Speci (Menu 305)
PF9100081473 5 - Enhancement Menu 305
PF9100181637 5 - Enhancement Short head -Short Pit: Car Position
changes
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100178308 2 - Major COP Detection for SCOPHM3 doses not work
PF9100180399 3 - Average Wrong Behaviour of Fire Recall Side ( First ).
PF9100180689 3 - Average ZZ3 mode:if EBR1 is activate after evacuation
both doors open
Improvement
-------------
PF9100178253 3 - Average New COP Package Design 11
PF9100178213 3 - Average New COP Package Design 10
PF9100081491 5 - Enhancement Improve LOP teaching IF changes
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please test also fixes of the release V9.8.15.
Please clear EEPROM before doing any upgrate to this version.
V9.9.1
--------
Delivered (d/m/y):31/03/2011
PC/NT : S00x.exe, 7785472 bytes
N/A
- New functionality: -
----------------------
PF9100181245 3 - Average SAIO2 support on ADDU
PF9100181246 3 - Average SAOI2 support on ECU
PF9100181247 3 - Average SAIO2 support additional HMI parameter
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100081474 3 - Average Solve String Problem for Speci
PF9100164270 3 - Average SW internal: snd:=xx or rcv:=xx results in
advanced (?) logging
PF9100181604 4 - Minor problem on CADI 2.99 during CF_DUMP (Re-
Submitted)
Improvement
-------------
PF9100178208 3 - Average New COP Package Design 9
PF9100181644 3 - Average New COP Package Design --> UI changes
PF9100178077 3 - Average New COP Package Design 7
PF9100178146 3 - Average New COP Package Design 8
PF9100181548 4 - Minor Cop package refactoring
PF9100081463 5 - Enhancement Re-design LOP teaching due to new COP
interface
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please test also fixes of the release V9.8.14.
Please clear EEPROM before doing any upgrate to this version.
V9.81.15
--------
Delivered (d/m/y):21/04/2011
PC/NT : S00x.exe, 7766528 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100181620 2 - Major BR3 BE : when DT-O is pressed and KBF or JBF
gets active elevator is Blocked.
PF9100181545 2 - Major Ui refactoring due to signalisation problem,
when overtemp and overload service active
PF9100181590 2 - Major elevator is blocked in safety chain error after
deactivation of LPC mode
PF9100164373 2 - Major Door problem with JBF
PF9100164352 3 - Average RPHT is disabled with EBR1 and parking with
open doors
PF9100081482 3 - Average Fix waiting view issue for Landing Panel
configuration with Speci
PF9100181668 3 - Average Missing service identifier for BR2 EN81-72
service
PF9100081475 3 - Average Solve String Problem for Speci
PF9100181639 3 - Average wrong behaviour of jab during pre_leveling
PF9100081488 3 - Average Fix Menu 320 for Speci
PF9100081492 3 - Average Fix Door Side info for Speci
PF9100178297 3 - Average CF04/PA98 - failed to set date/time with SPECI
PF9100081479 4 - Minor problem on CADI 2.99 during CF_DUMP (Re-
Submitted)
PF9100181567 3 - Average Rollback: Allow minummum CLC slope to be 4
instead of 5
Improvement
-------------
PF9100081484 5 - Enhancement Improve error log update when cleared
over Speci
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.8.14
--------
Delivered (d/m/y):17/03/2011
PC/NT : S00x.exe, 7766016 bytes
N/A
- New functionality: -
----------------------
PF9100181183 SW internal: Remove timer mgr wrap around after 2 days.
PF9100164318 6 - not applicable Support for SCCI board (COP part)
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100181546 2 - Major UCM: Fatal Error, after a timeout the door have
to close
PF9100181549 3 - Average DDC:problems with floor and car call on same
floor
PF9100181555 3 - Average Feedback from OEM policy test for UL - second
part
PF9100181557 3 - Average Unknown error in errolog E_ELEVATOR_UNKNOWN
logged instead of battery state
PF9100181478 3 - Average final timer+ KSKB error generate watch dog
reset
PF9100181568 3 - Average By restricted access the DTO is not reopening
the door
PF9100181493 3 - Average advance alarm filiter is invible on BX-CL after
learning
PF9100164333 3 - Average If KBFH1 and KBFH2 are connected to CANIO, BRH2
is not working
PF9100181544 3 - Average EEPROM conversion, shaft value are different
PF9100181481 3 - Average activation of fire during pre-leveling
performs syncro
PF9100181562 3 - Average ETMA : with SW V 9.8.13 Test Alarm doesn't
work.
PF9100181571 3 - Average sometimes elevator doesn't enter in "lpc" mode
PF9100181543 4 - Minor problem on CADI 2.99 during CF_DUMP
PF9100123782 4 - Minor KFM mode doesn't start in Full load
PF9100181547 4 - Minor CF_Dump : when the command Cf_dump is sent
elevator enter in Configuration for few second.
Improvement
-------------
PF9100081458 2 - Major Imrpove EN81 A3: stopping accuracy 5mm
PF9100081459 3 - Average Autotuning only with Emergency Stop active
PF9100181503 5 - Enhancement SW: Improve system_info answer (Re-
Submitted)
PF9100081461 5 - Enhancement Improve OEM packge interface
PF9100181589 3 - Average CADI: is working at 9600 only
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
SCIC Software Pair:
---------------------------------------
This version is tested to work with the following releases:
-------------------------------------------
Bootloader | V1.5
FC(CXS) | Deli 61 or Deli 68
FC(NXP) | 3.47
Yaskawa | 290
SEM | V2.0.05
BBCtrl | V4.1.02 (4.1 - KA)
CPLD (ISCPU) | V1.08
CPLD (SMIC6) | V1.08
COP1 | KA
COP2 | KA
COP3 | V2.1
COP3A | V3.0.15 (KA)
COP4 | V2.3.00
COP4ZLA/EU | V2.3.00
COP5 | V3.1.01
COP5AP | V1.5.01
COP5NA | V1.1
COPH | V2.1
COPH3 | V3.3.02
COPMAT | V3.3.02
CANIO | V1.1.01
SDIC2 | X
SDIC3 | X
SDIC3A | V2.5.04
SDIC4 | V2.5.04
SDIC41A | V3.1.05
SDIC5 | V2.8.01
SDIC53 | V2.8.01
SLCU-M | V2.1.03
SLCU2-M2| V2.1.03
SLCUx | V2.1.03
PSI | V2.1.01
SLCU-MX | V2.1.01
SLOPM2 | KA
SLINV5 | V1.1
SLOPE(L)51 | V1.5.01
SLOPE52 | V1.5.01
SLOPB4 | V1.5.01
SLOPBL41 | V1.5.01
SLOPEB52 | V1.5.01
SLOPBL42 | V1.5.01
SLOPDMA5 | V1.5.01
SLINK5 | V1.5.01
SLOPNA51/53| V1.5.01
SLOPNA52/54| V1.5.01
SLOPEBH5 | V1.5.01
SPECI | V1.31.6 8.01.2008
CADI | V2.92
CLSD | V1.4.11
Simcard | Filesystem V6
ACVF | V4
-------------------------------------------
x = NOT compatible
KA = look latest KA software available for that device
V9.8.13
--------
Delivered (d/m/y):03/03/2011
PC/NT : S00x.exe, 7758848 bytes
N/A
- New functionality: -
----------------------
PF9100181237 5 - Enhancement ETMA: new parameters must be implemented
PF9100164313 6 - not applicable Support for SCCI board (SDIC part)
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100164312 1 - Critical Elevator blocked in RPHT Monitoring
PF9100180683 2 - Major after OVERLOAD final timer is disable
PF9100181434 2 - Major in JRV elevator execute drifting parking and
remain blocked
PF9100081441 3 - Average Fix open Issues according tests Reach Phase 1
PF9100164302 3 - Average Full Load ends by serving a Car Call (Car Call
goes to pending state)
PF9100181429 3 - Average after conf. mode elevator doesn't execute
drifting parking
PF9100180583 3 - Average Lop Teaching is not possible with SW 9.8.03 on
BX- FA and BX-HY
PF9100181421 3 - Average during "LPC" mode if JAB is active elevator
doesn't make evacuation
PF9100181483 3 - Average OEM policy:watch dog reset during CF_DUMP
PF9100180698 3 - Average door error recovers during fire evacuation
elevator make syncro
PF9100081448 3 - Average OEM Policy levels fixes
PF9100181462 3 - Average ddc works always with default value=32
PF9100181308 3 - Average The input P_BAT_LOW is invisible in system info
on V9.8 (Re-Submitted)
PF9100181313 4 - Minor Fullload: car call with HMI or SPECI command
110 it's not working. (Re-Submitted)
PF9100181253 1 - Critical Verify eeprom conversion V9.8 (Re-
Submitted)
Improvement
-------------
PF9100181514 3 - Average 1: Refactoring Speci package
PF9100081455 3 - Average Fix ExtendedCnfgNormalMgr for WindowsBuild
PF9100181496 3 - Average Increase the timeout of menu 125 GBP Remote
Reset
PF9100177791 3 - Average New COP Package Design 6
PF9100181382 3 - Average EN81 A3: stopping accuracy 5mm
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.8.12
--------
Delivered (d/m/y):17/2/2011
PC/NT : S00x.exe, 7726080 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100180886 2 - Major HW evacuation on SMICE32 is not working
PF9100181433 2 - Major TimerMgr fix and improvements after assertion
feedback from the field (9.73.29)
PF9100180687 3 - Average zz3 mode:during activation of JNFF elevator
opens both doors
PF9100081445 3 - Average OEM Policy fixes
PF9100123926 3 - Average overload disable JDE-E KEY in schoolhouse
service
PF9100181427 3 - Average after PRE-LEVILLING elevator serves calls not
according policy
Improvement
-------------
PF9100081440 3 - Average Cleanup Includes for Rhapsody V7.5.2.1
PF9100081433 5 - Enhancement Adapt and verify UserLevels of OEM Policy
PF9100181426 5 - Enhancement New TEST command to test the pre-leveling
functionality without waiting 10 minutes
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.8.11
--------
Delivered (d/m/y):08/2/2011
PC/NT : S00x.exe, 7717888 bytes
N/A
- New functionality: -
----------------------
PF9100126772 3 - Average Special error handling for fully manual doors
on V9.8
PF9100177766 3 - Average GIH I/O on terminal reporting
PF9100081437 5 - Enhancement ETMA: Implement TM-NCM and TA_NCM in Menu
320
PF9100181371 5 - Enhancement REACH: Autocalibration menu and
functionality
PF9100081422 5 - Enhancement Bionic OEM support Speci, Cadi and OEM
enabler
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100181344 3 - Average Elevator goes in Fatal error if Eprom Was
Erased and Sim Card not Available.
PF9100177778 3 - Average OEM: IO Handler request BMK state is not
working on COPH
PF9100125711 3 - Average Learning started during a trip causes a fatal
PF9100181369 3 - Average During Lop Teaching COP doesn't show the
correct number of level and the the correct Countdown Timer.
PF9100181325 3 - Average VCF: Parking 6 do not works and Door continues
to close and reopen every CF3PA25 timer
PF9100181360 4 - Minor DTO on Second COP Doesn't work with SW V
9.8.09.
PF9100181358 4 - Minor CF12 do not shows correctly the SW version
Improvement
-------------
PF9100181364 3 - Average SW: To reduce NBC timer of JAB service to 10
minutes
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.8.10
--------
Delivered (d/m/y):26/1/2011
PC/NT : S00x.exe, 7673344 bytes
N/A
- New functionality: -
----------------------
PF9100181310 3 - Average DRIFT: 2 new configuration parameters on V9.8
(Re-Submitted)
PF9100181175 3 - Average Fire Service Parameter setting via HMI (Re-
Submitted) (Re-Submitted)
PF9100181298 3 - Average Phone call number reduction, CF24 menu (Re-
Submitted)
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100180838 1 - Critical Advanced Alarm Filter Doesn't works with
SW 9.8.06.
PF9100180939 1 - Critical Cop Detection doesn't work fine, and COP
Heartbeat is wrongly activated
PF9100181335 2 - Major Corrupted shaft information in case of 25
floors (short synchro executed without absolute encoder)
PF9100181271 2 - Major drifting:cf2 pa19 restarts from the beginning
after door movement
PF9100180807 2 - Major problem with EBR1 during "LPC" mode (Re-
Submitted)
PF9100181349 3 - Average Too many calls even without BB error log active
PF9100180941 3 - Average Advance Alarm Flter sometime doesn't work fine
if is connected two Cop.
PF9100181089 3 - Average elevator doesn't make an evacuation if activate
JAB after power OFF/ON
PF9100181274 3 - Average drifting mitigation:problem with drifting
during "LPC" mode
PF9100180773 3 - Average zz3 mode: E_DOOR_SHAFT_ERROR if on elevator
change evacuation floor
PF9100181262 3 - Average policy PI - landing call not accepted for a
while
PF9100181069 3 - Average Remove assert in polbase
PF9100181293 3 - Average parameter on CF 23 are disable on SW V 9.8.08
PF9100181362 6 - not applicable KBs errors and watchdog reset
Improvement
-------------
PF9100164185 4 - Minor Cleanup of the GNU_VXWORKS and the _MICROTEC
compiler switches
PF9100177390 3 - Average New COP Package Design 4
PF9100177641 3 - Average New COP Package Design 5
PF9100181068 3 - Average Allow minummum CLC slope to be 4 instead of 5
PF9100181294 3 - Average SW: Advanced log: improve recall command and
dump
PF9100181292 4 - Minor SW: COP Ack not working if HMI not on default
screen
PF9100181060 5 - Enhancement To identify Drive module for china (DMC)
PF9100181291 5 - Enhancement SW: Improve system_info answer
PF9100180936 5 - Enhancement SW: BIONIC/BX - System Info clean-up
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.8.09
--------
Delivered (d/m/y):23/12/2010
PC/NT : S00x.exe, 7616512 bytes
N/A
- New functionality: -
----------------------
PF9100180928 3 - Average UCM: New Persisten Fatal Error in case of Car
Unintended Movement
PF9100180929 3 - Average UCM: persistent fatal if the car drifts away
with open doors on V9.8
PF9100181150 5 - Enhancement SW: To change the trip counter
modification strategy (generic solution to notify configuration change)
PF9100181061 5 - Enhancement To parametrize REACH DMC drive
PF9100177481 5 - Enhancement IO Handler Interface exetention for 305
IO status
PF9100081360 5 - Enhancement UL2 support
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100081397 3 - Average Fix Menu 60 for SPECI
PF9100180870 3 - Average Correction doesn't works in NF1 trip.
PF9100180887 3 - Average DDC option is on SIM but CF2 PA18 is invisible
PF9100181270 3 - Average DRIFT: Anti drifting function SIM card Option
on V9.8 (Re-Submitted)
Improvement
-------------
PF9100180575 2 - Major Exract LPC mode from ElevatorSystem mode
PF9100081409 4 - Minor Correct integration feedback
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.8.08
--------
Delivered (d/m/y):13/12/2010
PC/NT : S00x.exe, 7574016 bytes
N/A
- New functionality: -
----------------------
PF9100181119 2 - Major JNFF 1-0-1 have to starts an evacuation trip
also after reset
PF9100180836 3 - Average advlog active by default
PF9100181058 3 - Average UCM: Rotor Monitoring, FC_STANDSTILL must be
turned into Persistent Fatal on V9.8
PF9100181002 3 - Average DRIFT: Anti drifting function SIM card Option
on V9.8
PF9100181003 3 - Average DRIFT: Parking after the specified timer on
V9.8
PF9100181064 3 - Average Unintended car movement AAT (UCM) on V9.8
PF9100181062 3 - Average DRIFT: new call trigger a correction on floor
after long inactivity on V9.8
PF9100180931 3 - Average DRIFT: 2 new configuration parameters on V9.8
PF9100181095 3 - Average Phone call number reduction, CF24 menu
PF9100181111 3 - Average ETMA: CF21 menu and eeprom structure V9.8
PF9100180997 3 - Average To limit the number of calls made due to errors
and recovery to a defined number on V9.8
PF9100081359 5 - Enhancement ES Tool support
PF9100081377 5 - Enhancement CF04 PA98 for Speci DateTime
configuration
PF9100164132 6 - not applicable TDO SW internal: Introduce
DoorsModes state pattern
PF9100164136 6 - not applicable TDO SW internal: Copy, rename and
adapt old TDO classes
PF9100164151 6 - not applicable TDO SW internal: remove
selective/interlocked hacks from DoorManager
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100181057 1 - Critical elevator blocked in normal mode (waiting
door lock (?)) on V9.8
PF9100181006 1 - Critical Watchdog reset after car call
cancellation on V9.8
PF9100181007 1 - Critical Verify eeprom conversion V9.8
PF9100181008 2 - Major during reversing device with KSKB elevator
enter in "LPC" MODE
PF9100181005 2 - Major GFAT: evacuation is not performed in case of FC
Fatal error on V9.8
PF9100180671 2 - Major DT-S is disable on SW V 9.8.04
PF9100180866 3 - Average Menu 110 generate always Assertion.
PF9100180872 3 - Average PI policy with parallel door
PF9100181124 3 - Average Watchdog reset BUSERR (during cf_dump) (Re-
Submitted)
PF9100180653 3 - Average BX Drive HY during Learning KOD-X is not
detected.
PF9100164162 3 - Average JKLBL KEY in schoolhouse service and ZBC2
Activation/Deactivation causes an Assertion
PF9100180979 3 - Average CLC recalibration should power CLC but not exit
LPC
PF9100181075 3 - Average problems in full load to serves CC
PF9100180998 3 - Average The input P_BAT_LOW is invisible in system info
on V9.8
PF9100180999 3 - Average Battery OK condition cound be missed on V9.8 (2
CRs)
PF9100181055 3 - Average some fatal error are not persistent, but the
HMI show Persistent (99) on V9.8
PF9100181063 3 - Average CF_DUMP success given before end of print on
V9.8
PF9100181096 3 - Average LL-X does not switch off if fire is actrive,
Selective doors fire -> overload -> fire
PF9100154471 3 - Average Connection with SPECI: Waiting view problem
PF9100181046 3 - Average LPC mode: after wake up elevator detects safety
chain open instead of emergency stop
PF9100180825 3 - Average CARLIGHT remain always ON with sim card option
PF9100180560 3 - Average SW V 9.8.03 preopening doesn't works
PF9100181031 3 - Average RESUBMITTED: communication device dead error
wrongly reported
PF9100180474 3 - Average double correction on 2 floor with restricted
access
PF9100126501 3 - Average Elevator invoke a correction trip inside the
door zone on V9.8
PF9100180692 4 - Minor Fullload: car call with HMI or SPECI command
110 it's not working.
PF9100180876 4 - Minor SW version missed during autoconfig
Improvement
-------------
PF9100164196 1 - Critical SW internal: remove "Factory" dependency
in LoadSensor
PF9100181145 2 - Major SCIC3 and SCIC5 are not supported any more
PF9100126697 2 - Major LOP Teach-in with FI-GS COP on V9.8
PF9100177308 3 - Average New COP Package Design 3
PF9100181004 3 - Average To make sim card equipment number visiblein HMI
on V9.8
PF9100180874 3 - Average DI2-Finish the implementation of the CAN error
frame detection and error reporting (Re-Submitted)
PF9100181056 4 - Minor HMI display not clear for side definition on
V9.8
PF9100081384 5 - Enhancement CF40_41 IDs for SPECI
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.8.07
--------
Delivered (d/m/y):11/11/2010
PC/NT : S00x.exe, 7304192 bytes
N/A
- New functionality: -
----------------------
PF9100180847 3 - Average Fire Service Parameter setting via HMI (Re-
Submitted)
PF9100081366 5 - Enhancement Bootloader HMI
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100180638 2 - Major LPC mode:after wake up with safety chain open
elevator enter in fatal
PF9100180647 2 - Major Extended Inspection AP: Deactivation of the
Inspection service is not possible.
PF9100180868 2 - Major BR3 KR: after trip with door open elevator
close a door (Re-Submitted)
PF9100180801 2 - Major elevator in "LPC" MODE doens't switch off
safety chain and brake supply
PF9100180806 3 - Average ACL isn't on SIM but carlight switch off
PF9100180626 3 - Average OUT of GROUP:after overload elevator doesn't
detect OUT OF GROUP
PF9100081368 3 - Average Fix Door side Info for Speci
PF9100180845 3 - Average LOP teaching error feedback: does not always
working as expected
PF9100180851 3 - Average ETM: line array read in the log is too short
PF9100180860 3 - Average br3 KR:during activation of JNFF problem with
safety chain overbridge and doors
PF9100180862 3 - Average ETMA: the recovery action is not working, in
case of communication lost between ETMA and controller
Improvement
-------------
PF9100177227 3 - Average New COP Package Design 2
PF9100176845 3 - Average New COP Package Design
PF9100180814 3 - Average Pure Virtual IF & factory for trafficMgr()
class --> Clean all dependency - Not To Test
PF9100177160 3 - Average Cleanup COP class files COP.hxx and COP.cpp
PF9100164107 3 - Average Door error recovery in case of an error already
registered (Implementation)
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.8.06
--------
Delivered (d/m/y):06/10/2010
PC/NT : S00x.exe, 7228928 bytes
N/A
- New functionality: -
----------------------
PF9100164101 3 - Average BR2EN8172UK Fire service for United Kingdom
amendment
PF9100180732 3 - Average 4: Low Power Consumption Mode --> Detailed
implementation for new SMIC Controller
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100180593 2 - Major EBR1 gets Active when Elevator is in COP
HB.People Trapped.
PF9100180587 2 - Major BR3 KR:wrong behaviour during evacuation phase
in FF
PF9100180588 2 - Major BR3 KR: after trip with door open elevator
close a door
PF9100180697 2 - Major br1 EN81type C evacuate always on H2 recall
floor
PF9100180564 3 - Average resubmitted:BR1 CH : KBF on SAIO wrong
behaviour during deactivation
PF9100180625 3 - Average When first Threshold gets active ( XTHMR )
Elevator make Always an Assertion.
PF9100180748 3 - Average elevator doesn't detect CAR LIGHT SENSOR
PF9100180684 3 - Average wrong address for NODE_DEAD on RMCC
PF9100180685 3 - Average MR dead and ALIVE but RMMC reports always
NODE_DEAD
PF9100180771 3 - Average ETM: backcall stops the retry call procedure
V9.8
PF9100180808 3 - Average Pure Virtual IF & factory for trafficMgr()
class ->Fix for Null Pointer
PF9100180812 3 - Average Lop Call in interlocked door mode keep opened
the door for infinite timeout
PF9100180728 3 - Average Wrong behaviour of NF1 with SW V9.8.04.
PF9100180619 3 - Average ZZ3 mode:deactivation of fire is wrong with 2
SIDE
Improvement
-------------
PF9100180497 3 - Average Optimized display behavior is not always
working as expected
PF9100180703 3 - Average Pure Virtual IF & factory for trafficMgr()
class
PF9100180758 3 - Average Add a command to trigger the Safety chain
periodic check
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.8.05
--------
Delivered (d/m/y):27/09/2010
PC/NT : S00x.exe, 7145472 bytes
N/A
- New functionality: -
----------------------
PF9100163955 3 - Average Fire Service Parameter setting via HMI
PF9100164063 6 - not applicable Support for SMIC32E
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100180613 2 - Major problem with EBR1 during "LPC" mode
PF9100180702 2 - Major BR2 EN81-73 (UK): Elevator was in FF and after
Power cycle Elevator perform Evacuation to Fire Recall
PF9100180723 2 - Major Avoid synchro at startup: wrong floor re-
alignment
PF9100180725 2 - Major RTC Blocked at startup second part
PF9100184556 3 - Average Parameter set to ETMA: SVID must be set as last
parameter
PF9100180658 3 - Average zz3 mode: elevator in NF1 service open both
doors after evacuation
PF9100180659 3 - Average lpc mode is disable for carlight without option
PF9100180644 3 - Average remove simcard option from system info
PF9100180621 3 - Average JRVC ( Indipendent Control Service ) in Policy
PI and DE Doesn't work.
PF9100180639 3 - Average ZZ2: door timing in selective door mode not
correctly handled in case of combination Car and Floor call on different side.
PF9100180642 3 - Average Change the UTC time could block the sending of
the statistic
Improvement
-------------
PF9100180711 3 - Average SW internal: reduce the usage of get_time
function V9.8
PF9100123727 3 - Average DI2-Finish the implementation of the CAN error
frame detection and error reporting
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.8.04
--------
Delivered (d/m/y):31/08/2010
PC/NT : S00x.exe, 7122432 bytes
N/A
- New functionality: -
----------------------
PF9100180623 2 - Major Avoid synchro at startup
PF9100180606 3 - Average 3: Low Power Consumption Mode --> Detailed
implementation
PF9100176802 3 - Average Power Safe Mode activation and deactivation
PF9100081338 5 - Enhancement Support 2nd door side for SPECI on
controller
PF9100081340 5 - Enhancement Support Elevator Operation State for
SPECI on controller
PF9100081330 5 - Enhancement Shaft for Absolute Encoder
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100180240 2 - Major RESUBMITTED:Elevator in NS 21 Doesn't Execute
Syncrotrio and remain Blocked.
PF9100180535 2 - Major RTC Blocked at startup
PF9100180631 3 - Average ZZ2 mode:both "ACK" on 2 COPH switch on after
one CC
PF9100180632 3 - Average MCCE31: output LEDs LR-D and LR-U not working
PF9100180528 3 - Average wrong feeback on cop display of lop teaching
PF9100180570 3 - Average all parameters on CF 22 are set to 0
Improvement
-------------
PF9100180648 3 - Average SW internal: prepare new package to allow
bootloader download
PF9100180596 3 - Average ETM: SSL session must be closed in a cleaner
way 2nd part
PF9100081331 5 - Enhancement Redesign CF15 Business Logics
PF9100176873 5 - Enhancement Adaption to CF15 refactory
PF9100081341 5 - Enhancement CF15 long DTO support
PF9100176817 5 - Enhancement GIO managing multiple BMK
PF9100164031 6 - not applicable SW internal: cleanup CarsComp 2nd
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.8.03
--------
Delivered (d/m/y):05/08/2010
PC/NT : S00x.exe, 7155200 bytes
N/A
- New functionality: -
----------------------
New Function PF9100126578 3 - Average Introduce new door DO DSF9 for V9.8
New Function PF9100180492 3 - Average 2: Low Power Consumption Mode -->
Detailed implementation
New Function PF9100155125 3 - Average Transmit the quality of ETMA-Link 2
and 3 to CC
New Function PF9100180384 3 - Average 1: Low Power Consumption Mode -->
Implementation of basic functionality
New Function PF9100081324 5 - Enhancement CF32
New Function PF9100081326 5 - Enhancement Service Executer for Power
Saving
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100180295 1 - Critical HY drive error: wrong behavior with
N_ISR deactivation
PF9100180469 1 - Critical New PI Policy make assert
PF9100180416 1 - Critical To make safety chain overcurrent
error persistent fatal on V9.8
PF9100180364 2 - Major RESUBMITTED : BR3 IN: JNFF on SIAP is
considered as FireFighter active even if BR3 IN has only JBF on V9.8
PF9100126767 2 - Major YASKAWA FC: fatal error during learning
trip on V9.8
PF9100126643 2 - Major overload during startup people trapped on
V9.8
PF9100126644 3 - Average RPHT failure no report on error log on
V9.8
PF9100071228 3 - Average BR3_Korea: firefight mode would be
deactived and elevator synch to bottom floor after reset
PF9100126499 3 - Average make blocked car detection active by
default on V9.8
PF9100126500 3 - Average Elevator go in fatal error after a
SDIC_HEARTBEAT on V9.8
PF9100126642 3 - Average Drive error input "READY" does not work
during learn trip on V9.8
PF9100126701 3 - Average increasing the number of buttons for the
domino configuration CF15 for COP AP on V9.8
PF9100126709 3 - Average Fully manual doors: SHBT -> door lock
released outside door zone on V9.8
PF9100126795 3 - Average Version 9.8: continuos resets on BX OL
PF9100126763 3 - Average EBR1: correction on floor where EBR1 is
active door opens
PF9100180297 3 - Average Acceptance test: activation during
fullload is not possible; Elevator is blocked in Maintenance mode on V9.8
PF9100180357 3 - Average RPHT-M doesn't work in duplex on V9.8
PF9100180358 3 - Average wrong behaviour of GS with ZZ0 on V9.8
PF9100101930 3 - Average RESUBMITTED - call isn't served
immediately while Car Call given before Timeout ends. PI Policy
PF9100180360 3 - Average RESUBMITTED : wrong value for CF30 on
V9.8
PF9100180374 3 - Average Arrival Gong in car give out sound twice
on V9.8
PF9100180375 3 - Average SCIC3: wrong ACID behaviour in
indipendent service on V9.8
PF9100180376 3 - Average ACID display works in over temperature on
V9.8
PF9100180367 3 - Average increasing the number of buttons for the
domino configuration CF15 for COP AP, EEPROM conversion on V9.8
PF9100180283 3 - Average BR2 FR, when doors closing and JNFF gets
active doors continius closing at normal speed.
PF9100180414 3 - Average BIC5+TSD and 1 side, second door shows
"??" on V9.8
PF9100180415 3 - Average wrong behaviour of CF 30PA1 in ZZ3 on
V9.8
PF9100180417 3 - Average RESUBMITTED: Automatic Car position: It
fails if invoked during Elevator is serving a Floor call on V9.8
PF9100180420 3 - Average Pin Code in selective door : enter pin
code on COP Side 2 but ACK is Shown COP on Side 1 on V9.8
PF9100126346 3 - Average motorovertemp.:in ZZ3 both doors opens
PF9100126409 3 - Average Elevator performs a reset after parking
PF9100180378 3 - Average RESUBMITTED: remote configuration: is not
possible to configure remotely the phone numbers on V9.8
PF9100180410 3 - Average communication device dead error wrongly
reported V9.8
PF9100180330 3 - Average COP and LIN Arrows doesn't show correct
way.
PF9100180521 3 - Average Call during Parking doesn't replace
parking call
PF9100126708 4 - Minor on system info is no correct information
about SAIO of SDIC 42 on V9.8
Improvement
-------------
PF9100180448 3 - Average SW internal: part 3 of interface
preparation to support the absolute encoder device (short synchro alignment)
PF9100180379 3 - Average Two CopH for for slective doors on V9.8
PF9100180425 3 - Average SW internal: part 2 of interface
preparation to support the short synchro alignment
PF9100180444 3 - Average Eliminate old policies Implementation
PF9100180377 3 - Average Display of the current String / phone
number on the higher lines on display on V9.8
PF9100180531 3 - Average ETM: SSL session must be closed in a
cleaner way
PF9100180525 3 - Average SW Internal : Implementation of pure
virtual interface for policyMgr Step 2
PF9100180440 3 - Average BR3 India update
PF9100180258 3 - Average Add the CF04 menu on CF_DUMP command on
V9.8
PF9100071237 3 - Average BR3KR: The door did not closed until the
car started to move when pressed JNFF-S and car call together.
PF9100164001 6 - not applicable SW internal: Cleanup Rhapsody
code generation CarsComp
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.8.02
--------
Delivered (d/m/y):09/07/2010
PC/NT : S00x.exe, 7141376 bytes
N/A
- New functionality: -
----------------------
PF9100163978 3 - Average BR2EN8172UK Fire service for United Kingdom
PF9100163979 3 - Average Floor on Fire, EBR1 for all countries not only
for BR2France
PF9100126736 3 - Average Car Call Cancellation, like SCH
PF9100126737 3 - Average Floor Call Cancellation, like SCH
PF9100081302 5 - Enhancement CF31, FireCnfgFile
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100180327 1 - Critical during COP-HB elevator doesn't performs
releveling V9.8
PF9100126699 3 - Average wrong value for CF30 on V9.8
PF9100180394 3 - Average Integration error 9.8.02
PF9100126455 3 - Average resubmitted:EBR1 is activated on destination
floor while car is travelling, Error is generated and Synchro is performed.
PF9100180262 3 - Average BR1 CH : KBF on SAIO wrong behaviour during
deactivation
PF9100176397 3 - Average BooleanArray add assert dependency
PF9100125836 3 - Average interlocked door mode:with GS elevator open a
door on restricted access
PF9100126703 3 - Average assertion with CF_DUMP on V9.8
PF9100126782 3 - Average NF1: any NF1 trip interruption lead to
evacuation lost
PF9100126795 3 - Average Version 9.8: continuos resets on BX OL
PF9100180300 3 - Average Low Power Consumption Frame Work
PF9100126706 3 - Average Elevator ignore RPHT active when start
Emergency Parking.
Improvement
-------------
PF9100126792 3 - Average Rhapsody trafficMgr dependency cleanup (new
stream)
PF9100126738 3 - Average Interlock priority on side: first people out,
then people in
PF9100126758 3 - Average SW internal: UML tool alignement for
CarController package
PF9100126766 3 - Average SW version information printed out when
resetting
PF9100126773 3 - Average SW internal: UML tool alignement for Ui package
PF9100180325 3 - Average SW internal: interface preparation to support
the short synchro alignment
PF9100176321 3 - Average Rhapsody addaption for Landing Panels
PF9100176393 3 - Average Improve Landing Panels for Rhapsody
PF9100180326 3 - Average GC_ERASE_EE: SRAM memory not erased V9.8
PF9100180271 3 - Average SW Internal : Eliminate friends relationtship
between Policy & policyMGR
PF9100180273 3 - Average SW Internal : Implementation of pure virtual
interface for policyMgr
PF9100180328 3 - Average Add the Overlay information on System Info V9.8
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.8.01 Rhapsody
--------
Delivered (d/m/y):18/05/2010
PC/NT : S00x.exe, 7078400 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
Improvement
-------------
PF9100126755 3 - Average SW internal: UML tool alignement for ETM
package
PF9100126753 3 - Average Elimination of all Visual Studio 06 related
files
PF9100126742 3 - Average 13: Rhapsody source code integration
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.8.01
--------
Delivered (d/m/y):05/05/2010
PC/NT : S00x.exe, 7075840 bytes
N/A
- New functionality: -
----------------------
PF9100126182 3 - Average New CGW device must be supported (CLSD/ETMA
family) for V9.8
PF9100126623 3 - Average DI2: the door state is not selective V9.8
PF9100126484 3 - Average RESUBMITTED: ETMA: phone number character set
extension for V9.8
PF9100163843 6 - not applicable SCIC: reserve msg for MICONIC MX
7.0
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100081289 1 - Critical Reservation problem on Windows platform
PF9100163890 1 - Critical Fire service does not work in duplex if
RPHT is active
PF9100126021 1 - Critical Biobus check: BioBus remain with short
circuit protection activated, then BIOBUS_DEAD_NODE reported many times
PF9100126518 1 - Critical Wrong behaviour in Duplex,floor call
remain scheduling and not served.
PF9100142476 1 - Critical KL-X, KL-V and KL-M do not work on COPH
PF9100142362 2 - Major Pin code does't work after COP fix input re-
factoring
PF9100126657 2 - Major ns21 has high priority than FF V9.8
PF9100126687 2 - Major Fully manual doors: Correction Trip does no
preopening V9.8
PF9100126203 2 - Major Elevator reset (null pointer) after 49 days for
V9.8
PF9100126205 3 - Average EBR1 - Doors close with default Timer for V9.8
PF9100126206 3 - Average RESUBMITTED:BR2 NL:no acctivation of fire with
JNFF on MR for V9.8
PF9100126208 3 - Average to disable the car descent monitoring durig
AATs for V9.8
PF9100176237 3 - Average Lop count does not clear all info for 9.8
PF9100126573 3 - Average Correction in Full Load, Car Call not served.
PF9100126586 3 - Average during Inspection or Recall operation if a
drive error occurs the door start opening V9.8
PF9100126654 3 - Average elevator runs with KTC bridged V9.8
PF9100126720 3 - Average Call served in the wrong sequence (turkish
feedback)
PF9100126413 3 - Average BX skips the ccurrent card reader call to serve
it afterwards V9.8
PF9100142203 3 - Average Rebase false merging
PF9100126475 3 - Average When Elevator serve a car call, and Firefighter
( BR2 FR ) is Activated , doesn't change destination.
PF9100176167 3 - Average COP - highest floor never displayed on Next
Destination Indicator Panel. for V9.8
PF9100126698 3 - Average Elevator state for Fatal and persisten fatal on
V9.8
PF9100126317 3 - Average SW internal: treshold between small msgs and
large msg is not correctly computed
PF9100126479 3 - Average During releveling car call serving order is
reversed V9.8
PF9100126488 3 - Average VS-DIR: Announced wrong direction for a
downwards car call on V9.8
PF9100126503 3 - Average Minimal Oil Level for HY: BMK are sent also in
CL drive on V9.8
PF9100126504 3 - Average Duplex + Biobus: updating process is performed
to many times and do not use Broadcast on V9.8
PF9100126505 3 - Average machine room node dead reports continuosly on
RMCC on 9.8
PF9100125834 3 - Average interlocked door in PI policy:double reversing
with RPHT and KSKB
PF9100126516 3 - Average Collective policy, for selective door,
scheduling missbehaviour (indian feedback)
PF9100126517 3 - Average Parking: elevator do not execute a parking if
car call on lowest floor.
PF9100126134 4 - Minor WinSim only: Seconds timestamps in error
history are wrong
PF9100124267 4 - Minor E_ELEVATOR_NO_ERROR reported with 0 value
PF9100126364 4 - Minor When Releveling is Active Lop and Car DTO
doesn't work.
PF9100126719 5 - Enhancement Policy Collective for
selective/interlocked Door Cleanup
Improvement
-------------
PF9100126700 2 - Major Biobus: Wrong Update process of Biobus nodes on
v9.8
PF9100126392 3 - Average 10: Rhapsody --> adapt original source code
with the origninal
PF9100126288 3 - Average 9: Rhapsody --> adapt original source code with
the origninal
PF9100126133 3 - Average 4: Rhapsody -> move source files to header
files
PF9100081278 3 - Average Improve and extend platform class
PF9100126498 3 - Average ETMA improvements to always detect the MRRT
modules V9.8
PF9100126254 3 - Average Resolve integration problems from: Delivery
9.71.17 to 9.8
PF9100126146 3 - Average 6: Rhapsody --> changes for better reverse
engineering
PF9100126179 3 - Average 7: Rhapsody --> synchronize rhap code
generation with origninal
PF9100126426 3 - Average ETMA improvements to understand the voice
communication status (call/disconnect reason) V9.8
PF9100126439 3 - Average Imporvement: acquire the GQN from simcard
PF9100126665 3 - Average 12: Rhapsody --> Delete of remaining
unneccessary dependencies
PF9100126664 3 - Average SW internal: task credits are not proportional
to task priorities V9.8
PF9100126576 3 - Average SW internal: prepare interfaces in car
controller to avoid direct use of doors in traffic controller
PF9100126571 3 - Average SW internal: bool
PolicyBaseClass::openDesignedDoor (Timeout timeout)
PF9100126599 3 - Average NS21 (All Types) LNOC Must be Device
Independent (Free BMK) on V9.8
PF9100142133 3 - Average Fix output list for CarIO for car fan (VEC) and
Car Light (KLC).
PF9100126231 3 - Average 8: Rhapsody --> synchronize rhap code
generation with origninal
PF9100126558 3 - Average 11: Rhapsody --> adapt original source code
with the origninal
PF9100126559 3 - Average Rhapsody --> add Model to clearcase
PF9100126138 3 - Average 5: Rhapsody --> remove rational rose comments
PF9100083509 5 - Enhancement COP: reserve messages for CMG project
PF9100081294 5 - Enhancement Execute Parking 4,5 and 6 in case car is
already on the floor
PF9100142147 5 - Enhancement Fix Input list for the COP standard BMK
inputs DTO, DTS, DVEC and DAC
PF9100142196 5 - Enhancement Fix Outputs-List on COP for the CAN
messages
PF9100081276 5 - Enhancement Build S00x for VS2008
PF9100126485 5 - Enhancement Change phone number configuration in CF21
on V9.8
PF9100081297 5 - Enhancement Reduce size of "init string for ETM" to
24 chars
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.71.19
--------
Delivered (d/m/y):23/02/2010
PC/NT : S00x.exe, 8601647 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100126374 1 - Critical Biobus check: BioBus remain with short
circuit protection activated V9.71
PF9100126352 2 - Major in JRV after reversing(rpht-kskb) door closing
PF9100126338 2 - Major deactivation of fire:elevator remain blocked
with door open
PF9100126309 3 - Average interlocked door:if elevator detects
COP_HB_MISSING both doors open
PF9100126259 3 - Average elevator detects COP_HB_MISSING, LAB on SLCUX
remain OFF on V9.71
PF9100126269 3 - Average Cop Domino in Selective Door : Cop Display
doesn't show the number above 9 ( Only the first digit is shown )
PF9100126382 3 - Average Call Serving Metrics & CarCall Generation
according direction
PF9100126321 3 - Average SW INTERNAL- REBUILD OS- HW PLATFORM: increase
space for message queues
PF9100126357 3 - Average BIC5, REFE and REFEH1 not working on SMIC
options plug
Improvement
-------------
PF9100126351 3 - Average ComboCall: Improved Distribution over the
group.
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
SCIC Software Pair:
---------------------------------------
This version is tested to work with the following releases:
-------------------------------------------
Bootloader | V1.5
FC(CXS) | Deli 61 or Deli 68
FC(NXP) | 3.47
Yaskawa | 290
SEM | V2.0.05
BBCtrl | V4.1.02 (4.1 - KA)
CPLD (ISCPU) | V1.08
CPLD (SMIC6) | V1.08
COP1 | KA
COP2 | KA
COP3 | V2.1
COP3A | V3.0.15 (KA)
COP4 | V2.3.00
COP4ZLA/EU | V2.3.00
COP5 | V3.1.01
COP5AP | V1.5.01
COP5NA | V1.1
COPH | V2.1
COPH3 | V3.3.02
COPMAT | V3.3.02
CANIO | V1.1.01
SDIC2 | X
SDIC3 | X
SDIC3A | V2.5.04
SDIC4 | V2.5.04
SDIC41A | V3.1.05
SDIC5 | V2.8.01
SDIC53 | V2.8.01
SLCU-M | V2.1.03
SLCU2-M2| V2.1.03
SLCUx | V2.1.03
PSI | V2.1.01
SLCU-MX | V2.1.01
SLOPM2 | KA
SLINV5 | V1.1
SLOPE(L)51 | V1.5.01
SLOPE52 | V1.5.01
SLOPB4 | V1.5.01
SLOPBL41 | V1.5.01
SLOPEB52 | V1.5.01
SLOPBL42 | V1.5.01
SLOPDMA5 | V1.5.01
SLINK5 | V1.5.01
SLOPNA51/53| V1.5.01
SLOPNA52/54| V1.5.01
SLOPEBH5 | V1.5.01
SPECI | V1.31.6 8.01.2008
CADI | V2.92
CLSD | V1.4.11
Simcard | Filesystem V6
ACVF | V4
-------------------------------------------
x = NOT compatible
KA = look latest KA software available for that device
V9.71.18
--------
Delivered (d/m/y):12/02/2010
PC/NT : S00x.exe, 8597551 bytes
N/A
- New functionality: -
----------------------
PF9100126168 3 - Average new function, use DVEC on the cop keys to
menage the car fan
PF9100126293 3 - Average SW internal : change internal sw behaviour for
special policy
PF9100126260 3 - Average RV1 & RV2 for interlocked door Mode
PF9100126188 3 - Average Overlay: Implementation of ServiceJobRequest
CanMessage IF & Controller related Functionality
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100126300 2 - Major Biobus still blocked after a unknown problem,
error EIO
PF9100126306 3 - Average Filter duplicated AcidDisplay Msg to cop
PF9100126318 3 - Average INDIA DUPLEX: one elevators clears the ack in
deceleration, the other when the door is open.
PF9100126284 3 - Average In fire mode DTO is not accepted on restricted
access
PF9100126289 3 - Average in PI with ZZ0 second COP doesn't works
PF9100126262 3 - Average PA6 in interlocked door mode wrong behaviour
PF9100126276 3 - Average Extend Card reader interface implementation: HW
& SW id, fill correct value
PF9100126273 3 - Average ETM: UKC phone number must be changed to
02476239547 (CIR: Nr. UKC3-090020) for V9.56
PF9100126275 3 - Average Connection broken after terminal command
"ETM_DUMP_EXTENDED_MESSAGES"
PF9100126281 3 - Average Internal SW only, FIX rebase problem
PF9100126326 3 - Average SW INTERNAL- Delete all call not performed if
calls are already in Idle State
PF9100126319 3 - Average Direction arrow are light up on the starting
floor
PF9100126320 3 - Average SW_INTERNAL Overlay: in case of change of
status of elevators big messages rush are generated
PF9100126321 3 - Average SW INTERNAL- REBUILD OS- HW PLATFORM: increase
space for message queues
PF9100126294 3 - Average Delayed Call Allocation
PF9100126299 3 - Average LOP teaching CF00 in parallel door mode opens
both doors
PF9100142283 3 - Average LAB configured on SDIC must be inverted but is
not inverted
Improvement
-------------
PF9100126124 3 - Average Rename proposal for OVERLAY_GROUP_PEERS_MISSING
and OVERLAY_GROUP_PEERS_RECOVERED
PF9100126236 3 - Average OverlayProxy refactory
PF9100081279 4 - Minor Group cleanup
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.71.17
--------
Delivered (d/m/y):29/01/2010
PC/NT : S00x.exe, 8568879 bytes
N/A
- New functionality: -
----------------------
PF9100126184 3 - Average FI-GS COP (CANCPG) missing HW id in CF13 & 302
PF9100126167 3 - Average New CGW device must be supported (CLSD/ETMA
family) for V9.71
PF9100081269 5 - Enhancement Add in CF07 PA10 LOP countdown timer
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100126242 3 - Average At the end of function Parking 6, new call are
not in every case executed
PF9100126230 3 - Average Combo call to the shaft borders
PF9100126160 2 - Major When the elevator goes in overload all car
calls are deleted.
PF9100126127 3 - Average 4: Update UI for interlocked /Selecitve doors
PF9100126162 3 - Average FloorCallLockOff not working with Overlay
PF9100142146 3 - Average Access side not correct on COP and COPH with
getInput and setOutput
PF9100126140 3 - Average RESUBMITTED: Elevator is blocked if User Enter
in Menu 111 ( floor Call from HMI )
PF9100126181 3 - Average resubmitted: RV2 active DT-S is disable ,door
remains open
PF9100126183 3 - Average Extend Card reader interface implementation: HW
& SW id
PF9100126189 2 - Major Elevator reset (null pointer) after 49 days for
V9.71
PF9100126192 3 - Average Duplex: some time a LOP ACK still ON when
landing call has served by other elevator
PF9100126116 3 - Average RESUBMITTED:LOP with wrong configuration
reports continuosly Node dead
PF9100126121 3 - Average FIGS not reported correctly in System_info
PF9100126122 3 - Average System_Info the COP keys statue is wrong
PF9100126190 3 - Average EEPROM conversion for V9.71
Improvement
-------------
PF9100126193 3 - Average In case of 1-N COP: the COP should indicate
only the floors where a door is available on its side
PF9100126195 3 - Average In case of 1-N COP: the COP should indicate
only the floors where a door is available on its side.
PF9100126196 3 - Average Timer for Out Of Group
PF9100081270 5 - Enhancement CF41 LEx store values for both sides in
case of parallel and old door mode
PF9100081274 3 - Average Change timeout for OutOfGroup timer in of Final
Timer available
PF9100126119 3 - Average SW internal: Isolate carCall from overlay when
special polisy is activated
PF9100126120 3 - Average Lop DTO interlocked policy
PF9100126110 3 - Average SW internal: Eliminated GNU compile worning
message from trafficMgr package
PF9100081265 4 - Minor File size calculation on Windows platform
problem
PF9100125969 3 - Average selective door : insert new parameter (SIDE
MAIN FLOOR)
PF9100126191 3 - Average New CF parameter for Out Of Group timer
PF9100081263 2 - Major Group for selective doors phase 4
PF9100126153 3 - Average Lop teaching countdown (12s) too little with
SLIN52 or make double teaching with same address
PF9100126237 3 - Average DI2 CF menu should be visible for all PA
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.7.16
--------
Delivered (d/m/y):16/12/2009
PC/NT : S00x.exe, 8552495 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100125859 3 - Average submitted:selective door:problems with
reversing device
PF9100126081 3 - Average Overlay errors are not sent to RMCC + resource
overlay changed 37 -> 47
PF9100141962 3 - Average VEC does not work
PF9100126086 4 - Minor Overlay integration day 15122009
PF9100126104 2 - Major elevator in out of group (duplex conf.) fire is
disable
PF9100126076 3 - Average AAT: After Runtime limiter test elevator goes
in KNE
PF9100124419 3 - Average 3: Update UI for interlocked /Selecitve doors
--> add filter for gong
Improvement
-------------
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.7.15
--------
Delivered (d/m/y):11/12/2009
PC/NT : S00x.exe, 8548399 bytes
N/A
- New functionality: -
----------------------
PF9100126046 3 - Average Overlay reset command
PF9100126001 3 - Average Overlay Error Handling
PF9100081254 5 - Enhancement Group for selective doors phase 3
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100125896 3 - Average Elevator is blocked if User Enter in Menu 110 (
Car Call from HMI )
PF9100125909 3 - Average selective door: impossible to conf. key on SIDE
2 of LOP (cf40 pa21)
PF9100125923 3 - Average On Restricted Access if Alarm botton is pressed
doors open.
PF9100125971 3 - Average press alarm button on cop without side elevator
make a syncro
PF9100125983 3 - Average 3: Update Ui for Selective and Interlocked mode
PF9100125988 4 - Minor wrong default value of car_load_sensor (cf8
pa8=0)
PF9100125989 1 - Critical Service Visit (Moscow) and Overlay:
Elevator execute the Group calls
PF9100125990 3 - Average Overlay error Handling
PF9100125510 3 - Average Door Signalization on HMI is not Correct With
Selective Doors ( Interlocked )
PF9100125848 3 - Average The SMIC and SCIC version in system info is
wrong
PF9100125994 3 - Average Out of group for overlay kill call in normal
mode & fix in checkForFurterCall
PF9100125997 3 - Average startup Overlay HW presence verification
PF9100126012 3 - Average overload in interlocked :sometimes acoustic
signal is disable
PF9100126016 3 - Average COP-LD: light sensor is never detected, remain
undefined
PF9100083542 3 - Average door error from SCIC.door-package DI2-msg wrong
PF9100125943 3 - Average RESUBMITTED:LOP with wrong configuration
reports continuosly Node dead
PF9100126033 1 - Critical Overlay system blocked without evacuation
in JAB
PF9100083577 2 - Major elevator blocked in correction trip
PF9100126055 3 - Average Overlay can Id & shaft door Error
PF9100125755 3 - Average elevator open both door after CC in
out_of_group
PF9100141828 3 - Average Resupport legacy COPs
PF9100125968 3 - Average INTERLOCKED DOOR:in JRV both doors open
PF9100124990 3 - Average LOP acknoledge is not cleared in OutOfService
Improvement
-------------
PF9100126066 3 - Average SW internal: further partial undo of BB changes
(CR81211- CR126045)
PF9100126045 3 - Average SW internal: further partial undo of BB changes
(CR 81211)
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.7.14
--------
Delivered (d/m/y):03/12/2009
PC/NT : S00x.exe, 8544303 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100125981 3 - Average Selective Doors ( 128 = 0 ) COP DTO Doesn't
work where only Side 2 is present.
PF9100125959 3 - Average COP5 AP: CF00 floor selection with domino
keyboard does not work: PROCITS JSG1-090021
PF9100125967 3 - Average Selective Door ( 128 = 0 ) Car call to Floor 1
where only Side 2 is present is not served.
PF9100125972 3 - Average LBFC does not work on SIEU in BR russia
PF9100125978 3 - Average Overload opens both doors if overload is
reached while door is reopening
PF9100125469 3 - Average 2: Update Ui for Selective and Interlocked mode
PF9100125962 3 - Average SW internal: MSG_SERVICE_VISIT is not deleted
Improvement
-------------
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.7.13
--------
Delivered (d/m/y):01/12/2009
PC/NT : S00x.exe, 8544303 bytes
N/A
- New functionality: -
----------------------
PF9100081237 5 - Enhancement Group for Selective Doors
PF9100081242 5 - Enhancement Overlay command interpreter cmds
PF9100081241 5 - Enhancement Group for Selective Doors Phase2
PF9100083529 2 - Major Sel Doors: Door Error Recovery/Safety
Chain Interrupted Recovery
PF9100125842 3 - Average Development from Overlay EBI day 17.11.09
PF9100141356 5 - Enhancement Teaching of LOP, LIN or LOP-LIN
combination (+SLCUX)
PF9100125861 3 - Average Development from Overlay LOC day 19.11.09
PF9100125777 3 - Average RESUBMITTED :HW and SW identification of
overlay version Menu implementation
PF9100125878 3 - Average UI update for selective and interlocked
doors
PF9100141747 3 - Average Support of the HW ID of the FI-GS COP
(CANCPG)
PF9100081239 6 - not applicable ClearCase Windows 7 Test
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100125763 3 - Average Overlay System,when one of two Elevator
goes in Out Of Service Some Calls remain Pending.
PF9100125756 2 - Major Compatibility of the SIM-Card Options
PF9100125754 1 - Critical Full Load in Overlay system blocked
Elevator.
PF9100081238 1 - Critical Fix deadlock CCAlarmSupervisor
PF9100081247 1 - Critical Fix delivery issues from Kaspar
PF9100083535 2 - Major DTS in Firefighter mode is not working
and Car Controller make Exception during Fire Evacuation travel
PF9100125924 3 - Average ETM: UKC phone number must be changed to
02476239547 (CIR: Nr. UKC3-090020)
PF9100125713 3 - Average 3: Rhapsody Bionic Source Code cleanup
PF9100125511 2 - Major Graceful Fatal Error with Selective doors
( Interlocked ) Doesn't work.
PF9100125704 3 - Average Overlay: LOP DT-O is not working in case
of Overlay duplex
PF9100125706 3 - Average bmk code change: DVEC moves from 967 to
185
PF9100081252 3 - Average Adapt PI policy for new group
PF9100125621 2 - Major Ovelay: Elevator is not clear the call
pool of overlay in case of JBF
PF9100125850 3 - Average selective door :FF on BR3 STD wrong
behaviour
PF9100125853 3 - Average EEPROM conversion on V9.7
PF9100125852 2 - Major Firefighter in Selective Doors ZZ3
( Interlocked ) only one Cop ( First ) accecpt calls.
PF9100125855 3 - Average interlocked door mode:new call during
travelling to parking, call served but open both doors
PF9100125884 3 - Average Overlay:Can protocol logging + general
fixes
PF9100125875 3 - Average CF17 HMI menu have to be removed
PF9100125876 3 - Average Interlock: CF30 PA21 set default value
SIDE_1 and PA22 set default value SIDE_2
PF9100125887 2 - Major Attendant Service with SW 9.7.12 Doesn't
works.
PF9100125477 2 - Major JAB: Elevator remain in Out of service
with JAB = OFF
PF9100125480 2 - Major SELECTIVE DOOR:in JRV both COP are
disable
PF9100125779 3 - Average RESUBMITTED BR3 RU: firefighter mode, DTO
is working while the doors are closing
PF9100125572 3 - Average Travel direction, Gong, LA should be
avaialable only on side when door opens
PF9100125356 3 - Average indexQueue problem (SW internal
improvements)
PF9100125926 3 - Average RESUBMITTED: COP detection (129__1) do
not persistently store the information of detected COP
PF9100125929 3 - Average Assertion in CaQueue.hxx 412 during
endurance test
PF9100125931 3 - Average Task blocked: RamidExe during endurance
test
PF9100125806 3 - Average selective dooor mode :with alarm button
both doors open with ZZ2 mode
PF9100125814 3 - Average at start up is always present
E_ELEVATOR_COP_HB_MISSING (with 2 COPS)
PF9100125815 3 - Average with 3 digit of PIN CODE ,wrong CODE
doesn't show error on COP(4 DIGIT OK) on V9.7
PF9100125526 2 - Major Automatic Car Positioning: Car is not
traveling to LDU floor
PF9100125532 3 - Average LI service: if elevator detects JAB
elevator enter in p. fatal error on V9.7
PF9100125626 3 - Average Controller send wrong information about
door statistics to RMCC
PF9100125350 2 - Major NS21:wrong behaviour ,doesn't starts
evacuation phase,people trapped
PF9100125890 3 - Average Overlay:Call propagation & lerning
service
PF9100125813 3 - Average interlocked mode:door_error works on both
doors
PF9100125825 3 - Average Lop ACK doesn't switch ON when user make
car call to protected floor ( GS ) and door are not closed.
PF9100125818 3 - Average selective door:teaching on one floor
elevator make wrong LOP COUNT of SIDE2
PF9100125821 3 - Average SAS with SW 9.7.11 SD doesn't work.
Improvement
-------------
PF9100083469 5 - Enhancement System_Info: TSD and KSR_A missing
PF9100125934 3 - Average Default door mode must be new parallel
mode (instead of old parallel mode)
PF9100125370 4 - Minor report on RMCC side where bio bus node
dead
PF9100125847 3 - Average SW internal refactoring: implement CL as
component
PF9100081236 5 - Enhancement Service Visit improvement
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.7.12
--------
Delivered (d/m/y):17/11/2009
PC/NT : S00x.exe, 8478767 bytes
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100125746 2 - Major selecive door:problems with reversing device
PF9100125758 2 - Major elevator in full load doesn't serve CC pending
PF9100125753 2 - Major RPHT active after 30 seconds elevator enter in
OUT of GROUP
PF9100125761 3 - Average ZBC1:door at restricted floor is open with DTO
PF9100083473 2 - Major BR3 BE with Selective Doors ( Selective ZZ2 ) ,
Firefighter doesn't work.
PF9100125799 2 - Major In parallel door mode call so secon acces are
accepted
PF9100125801 2 - Major Selective: PI policy wrong groupCall
ElevatorCall coupling
PF9100141359 5 - Enhancement Emergency STOP doesn't delete group call
on SIDE 2
PF9100125765 3 - Average ZB3 doesn't works with selective door
PF9100125766 3 - Average NS21: if the trigger is activated during a
normal trip, an assertion occurs
PF9100083500 2 - Major HMI on SMIC32 works only partially
PF9100125819 3 - Average Policy PI with SW 9.7.11 SD Doesn't work.
Improvement
-------------
PF9100141619 5 - Enhancement Default side SIDE_BOTH for COP package
PF9100125789 3 - Average RESUBMITTED : ZBC2 Wrong Behavior for 9.7
PF9100125762 4 - Minor ETM(A): add CF explanation to list_etm_cnfg
command
Rejected:
-------------
PF9100125676 3 - Average CarController-> correction job must handle side
information
PF9100125769 3 - Average Overlay:New load & elevator operating state
messages
PF9100125774 5 - Enhancement Selective Doors Pincode works only for
side 1
PF9100125826 3 - Average Development from Overlay Lab day
PF9100125787 3 - Average SW internal: Filter DTO on trafficMgr in order
to avoid opening door on restricted access.
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.7.11
--------
Delivered (d/m/y):30/10/2009
PC/NT : S00x.exe, 8470575 bytes
N/A
- New functionality: -
----------------------
PF9100083481 3 - Average Implementation of selective DTO handling
PF9100125680 3 - Average New SIEU HWID for MOS
PF9100141326 3 - Average Extend Card reader interface implementation for
SD
PF9100125575 3 - Average Selective door - Restricted Access
Functionality
PF9100125697 3 - Average Overlay detection Menu
PF9100125698 3 - Average Overlay detection store in EEPROM
PF9100125699 3 - Average Overlay Monitoring HMI Menu Implementation
PF9100125700 3 - Average Overlay Reset Menu Implementation
PF9100125538 3 - Average Additional new floor designation charset for AP
PF9100124560 3 - Average SelDoors: Doors state feedback changes
PF9100125505 3 - Average HW and SW identification of overlay version
Menu implementation
PF9100124827 3 - Average Selective Doors Functionality
PF9100124829 3 - Average Selective Doors Prototype : Attendant servicies
for new policies
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100141130 3 - Average Update floor call acknowledgements after SBBD
switch
PF9100125508 3 - Average 2: Rhapsody Bionic Source Code cleanup
PF9100125707 3 - Average Car call acknowledge on COP does not work
PF9100125582 3 - Average Split ETMComponent in two files
PF9100125371 3 - Average dead and alive node(SLCUX-MR) LOP CHECK is
absent for OUTPUT LAMP
PF9100125486 3 - Average Selective Door: Both door opens at the same
side when LOP teaching
PF9100125533 3 - Average BR3 RU: firefighter mode, DTO is working while
the doors are closing
PF9100081222 3 - Average Service Visit is not on ( 117 = 1 ) When
Elevator enter in Recall mode.
PF9100141151 3 - Average Biobus SCAN gets stuck if LCUM+LCUX on first
floor do not answer for 9.7
PF9100125636 3 - Average SCPU field return analysis: Extend startup
procedure with a RealTimeClock check
PF9100125438 3 - Average PIN CODE Doesn't work with SW 9.7.08
PF9100125461 3 - Average SIEU, IN1,7,8 don't work
PF9100125643 2 - Major Elevator in COP_HB after Reset Return in Normal
mode.
Improvement
-------------
PF9100141325 2 - Major Missing access side info in the car calls
PF9100141358 5 - Enhancement ZBC2 re-factoring for COP
PF9100141172 3 - Average RESUBMITTED : ZBC2 Wrong Behavior for 9.7
PF9100083480 3 - Average SW internal: move DTO/DTS notification from Car
to Doors
PF9100081234 1 - Critical Fix merge problem V9.54 into V9.7
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
SCIC Software Pair:
---------------------------------------
This version is tested to work with the following releases:
-------------------------------------------
Bootloader | V1.5
FC(CXS) | Deli 61 or Deli 68
FC(NXP) | 3.47
Yaskawa | 290
SEM | V2.0.05
BBCtrl | V4.1.02 (4.1 - KA)
CPLD (ISCPU) | V1.08
CPLD (SMIC6) | V1.08
COP1 | KA
COP2 | KA
COP3 | V2.1
COP3A | V3.0.15 (KA)
COP4 | V2.3.00
COP4ZLA/EU | V2.3.00
COP5 | V3.1.01
COP5AP | V1.5.01
COP5NA | V1.1
COPH | V2.1
COPH3 | V3.3.02
COPMAT | V3.3.02
CANIO | V1.1.01
SDIC2 | X
SDIC3 | X
SDIC3A | V2.5.04
SDIC4 | V2.5.04
SDIC41A | V3.1.05
SDIC5 | V2.8.01
SDIC53 | V2.8.01
SLCU-M | V2.1.03
SLCU2-M2| V2.1.03
SLCUx | V2.1.03
PSI | V2.1.01
SLCU-MX | V2.1.01
SLOPM2 | KA
SLINV5 | V1.1
SLOPE(L)51 | V1.5.01
SLOPE52 | V1.5.01
SLOPB4 | V1.5.01
SLOPBL41 | V1.5.01
SLOPEB52 | V1.5.01
SLOPBL42 | V1.5.01
SLOPDMA5 | V1.5.01
SLINK5 | V1.5.01
SLOPNA51/53| V1.5.01
SLOPNA52/54| V1.5.01
SLOPEBH5 | V1.5.01
SPECI | V1.31.6 8.01.2008
CADI | V2.92
CLSD | V1.4.11
Simcard | Filesystem V6
ACVF | V4
-------------------------------------------
x = NOT compatible
KA = look latest KA software available for that device
V9.7.10
--------
Delivered (d/m/y):02/10/2009
PC/NT : S00x.exe, 8376367 bytes
N/A
- New functionality: -
----------------------
PF9100125539 3 - Average Additional statistic for reversing (RPHT &
KSKB) Menu visualization
PF9100124580 3 - Average SelDoor: Parking door side destination
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100125514 2 - Major BR3 BE with Selective Doors ( Selective ZZ2 ) ,
Firefighter doesn't work.
PF9100125479 3 - Average selective doors:with FULL or OVER load both
doors reopens
PF9100125481 3 - Average on both COP next destination indicator shows
all positions
PF9100125483 3 - Average parameters access side(CF30) wrong behaviour of
doors
PF9100124893 3 - Average LOP teaching timeout is cancel after a
successful teaching
PF9100125555 3 - Average OS Compilation
Improvement
-------------
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.7.09
--------
Delivered (d/m/y):11/09/2009
PC/NT : S00x.exe, 8228911 bytes
N/A
- New functionality: -
----------------------
PF9100125300 3 - Average Resolve Merge problems 9.7 to 9.7
selective doors
PF9100083396 3 - Average SelDoor: Selective opening of the doors
in the fire emergency landing
PF9100124753 3 - Average Selective Doors Prototype :
TrafficManager Adaptations
PF9100124577 3 - Average SimCard: new option for parallel,
selective and interlocked doors
PF9100124578 3 - Average SelDoors: Fire service doors side
destination
PF9100124579 3 - Average SelDoors: Configuration doors side
destination
PF9100081171 5 - Enhancement Support CarController for Selective
doors
PF9100124765 3 - Average SelDoors: COP side assignment
configuration
PF9100124544 3 - Average LOP selective addressing
PF9100124559 3 - Average SelDoor: Doors management changes
(prototype)
PF9100124812 3 - Average Selective Doors Prototype :
TrafficManager Adaptations Second Phase
PF9100124823 3 - Average Selective Doors Prototype :
TrafficManager Adaptations - Scheduling Combo Call
PF9100124849 3 - Average Selective Doors Prototype : Fix making
working elevator call for second access
PF9100081199 5 - Enhancement SelDoor: Building Side
Configuration in CF30
PF9100081210 5 - Enhancement SelDoors: Car Call cancellation
PF9100081162 5 - Enhancement Support selective doors for
configuration
PF9100124824 3 - Average Selective Doors Prototype :
TrafficManager Adaptations - Update checkForFurtherCall Method
PF9100124825 3 - Average Selective Doors Prototype :
TrafficManager Adaptations - Schedule calls according call Availability
PF9100124826 3 - Average Selective Doors Prototype :
TrafficManager Adaptations - Making works again old policies
PF9100124828 3 - Average Selective Doors Prototype :
TrafficManager Adaptations - Differentiate Combo/Twins Call
PF9100124830 3 - Average Selective Doors Prototype :
TrafficManager Adaptations - PI/DE policy for selective doors
PF9100124871 3 - Average 1:SelDoors: Extend UI IF: LOP UI
PF9100083293 6 - not applicable SW internal: Prepare doorIF
for selective doors
PF9100125443 3 - Average Selective Doors Prototype :
TrafficManager Adaptations - Filter cas call to nonexistentaccess
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100083205 4 - Minor Bio2 secure input on side2 - contiuous
BioBus-Reset
PF9100140461 1 - Critical Adapt merge to the new IO Handler
implementation
Improvement
-------------
PF9100125272 3 - Average 1: Statistic for 2 doors
PF9100081182 3 - Average Build speed up for Windows Platform
PF9100081175 5 - Enhancement Controller adaptations for new
WinSim as well for Selective doors
PF9100081206 3 - Average SelDoors: Check all position trips issued
by Services
Rejected:
-------------
PF9100124518 2 - Major DOD6 doors: elevator blocked regularly without
visible reason
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.7.08
--------
Delivered (d/m/y):03/09/2009
PC/NT : S00x.exe, 8220719 bytes
N/A
- New functionality: -
----------------------
PF9100140870 5 - Enhancement Group BMKs Overlay Device Handler
PF9100140871 5 - Enhancement Group BMK Routing
PF9100081216 5 - Enhancement Test Alarm
PF9100125355 3 - Average ETMA parameters handling with servitel
messages
PF9100125333 3 - Average ETMA: battery monitoring, battery active
PF9100125375 3 - Average SW internal: move ETM error definitions
in a dedicated file
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100081217 3 - Average Memory problem in InputTable of IO
controller
PF9100081219 3 - Average Problem setting 3 digit pin code, wrong 3
digit pin code error not shown
PF9100125271 3 - Average Reduced Volume VS: the CF6 PA20 low
volume, has not effect on any VS and GSC.
PF9100125374 3 - Average SW internal: avoid dependencies from core
code to components
PF9100125377 3 - Average CLSD/ETMA detection causes a watchdog
reset if it is triggered with HMI
PF9100125335 2 - Major Reset during learning with TSD elevator
(ETMA detection causes deadlock)
PF9100125340 2 - Major after reset during service visit
(RUSSIA),CC and LC are enable
PF9100125337 1 - Critical RESUBMITTED: door lock monitoring:
Lamp RLUO not updated after power off on.
Improvement
-------------
PF9100125236 5 - Enhancement improvement of system info V9.7
PF9100081215 5 - Enhancement Replace Msg Macros with Template
PF9100081214 3 - Average Implementation of Overlay Pipe
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
>>> Please clear EEPROM before doing any upgrate to this version. <<<
V9.7.07
--------
Delivered (d/m/y):14/08/2009
PC/NT : S00x.exe, 8'220'719 bytes
N/A
- New functionality: -
----------------------
PF9100081207 3 - Average Additional ETMA HMI configuration
Implementation
PF9100125295 3 - Average SimCard: new option for selective doors V9.7
PF9100125297 3 - Average 2:Additional statistic for ACL Implementation
PF9100125316 3 - Average ETMA: battery monitoring preparation
PF9100125246 6 - not applicable Overlay Functionality
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100123284 3 - Average Assertion during endurance (JobListener.cpp
160)
PF9100124487 3 - Average DI2: EDEM test information is collected after
the stop and not when the error occurred
PF9100124491 3 - Average DI2: EDEM test Trip state success reported
wrongly
PF9100125218 3 - Average 1: Rhapsody Bionic Source Code cleanup
PF9100125273 3 - Average Services - Car Controller protocol could lead
to a continuos reset
PF9100124855 4 - Minor Voice announcer not active in overtemperature.
PF9100125229 4 - Minor ETM: wrong statistic with command
etm_get_errors
PF9100125265 4 - Minor ETMA: reset must not be given after alarm off-
hook -> on-hook transition
Improvement
-------------
PF9100125217 3 - Average Speci re-factoring step4
PF9100125238 3 - Average 2: Voice Announcer Time activation
PF9100140652 3 - Average SBBD: improvement on slave elevator B
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
>>> Please clear EEPROM before doing any upgrate to this version. <<<
V9.7.06
--------
Delivered (d/m/y):13/08/2009
PC/NT : S00x.exe, 8'159'279 bytes
N/A
- New functionality: -
----------------------
PF9100125288 3 - Average MOS: Contact Door Elevator Controller
box/cabinet (UI side)
PF9100125289 3 - Average MOS: Contact Door Elevator Controller
box/cabinet
PF9100081213 5 - Enhancement New definitions and changes for MOS
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100125016 1 - Critical elevator blocked with FireFighter actives
(unrealistic case)
PF9100083438 2 - Major Inverted inputs from COPH don't work
PF9100125226 2 - Major Configuration output for SIEU (CF49) not
persistently stored
PF9100125232 2 - Major Door lock monitoring for S001R3 MOS: Lamp RLUO
not working if configured on SIEU
PF9100125247 2 - Major Door lock Monitoring for RU: Service Visit if
active car and floor calls are accepted
PF9100125248 2 - Major Door Lock Monitoring: Failure not detected if
KNET is activated during service visit switched OFF
PF9100083439 3 - Average COPH doesn't works in FF with JAB active
PF9100125049 3 - Average Short KNET signal change activates the TSD
inspection
PF9100125222 3 - Average BR3- RU wrong behaviour in door closing
conditions
PF9100125233 3 - Average door lock monitoring: Lamp RLUO not updated
after power off on.
Improvement
-------------
PF9100081209 3 - Average Different changes for Display and HMI
PF9100140365 5 - Enhancement GIO: Car Device Handler: Auxiliary IO
incl. SIAP, SIEU on all SDIC
PF9100140784 1 - Critical Adapt changes in the abstract
DeviceHandlerInterface
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
>>> Please clear EEPROM before doing any upgrate to this version. <<<
V9.7.05
--------
Delivered (d/m/y):15/07/2009
PC/NT : S00x.exe, 8'159'279 bytes
N/A
- New functionality: -
----------------------
PF9100124764 3 - Average ETMA HMI configuration Implementation, new PA
PF9100124847 3 - Average Additional statistic for ACL Implementation
PF9100124848 3 - Average Additional statistic for ACL Menu visualization
PF9100125044 3 - Average Doors Lock Monitoring Implementation
PF9100125076 3 - Average ETMA new HW must be detected
PF9100125158 3 - Average ETMA new init string
PF9100125164 3 - Average Out of service on COP Implementation
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100125093 2 - Major LCD backlight: do not switch OFF after timeout
Improvement
-------------
PF9100125045 3 - Average Update menu 117 Service Visit
PF9100081203 5 - Enhancement Review integer data types
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
>>> Please clear EEPROM before doing any upgrate to this version. <<<
V9.7.04
--------
Delivered (d/m/y):04/06/2009
PC/NT : S00x.exe, 8,110,127 bytes
N/A
- New functionality: -
----------------------
PF9100124846 3 - Average Voice Announcer Time configuration
PF9100124820 3 - Average BR3 (MOS) Fire service
PF9100124821 3 - Average BR3 MOS Fire Service SIM Card option
PF9100124557 3 - Average Voice Announcer Time activation
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100083321 2 - Major people trapped in fire service with SDIC RESET
PF9100071224 3 - Average Attendant service(LI): Switch on JLI one time,
a registered car/floor call would be canceled
Improvement
-------------
PF9100140416 2 - Major Re-Integration GIO: Interface extension
PF9100140422 2 - Major Re-Integration Cop Device Handler: Auxiliary IO
on all COPs
PF9100140411 2 - Major Re-integrate Remove Landing Panel dependencies
PF9100081193 3 - Average Use short timeout for long shaft types
PF9100081191 5 - Enhancement Change rough position information on HMI
according new definitions
PF9100140461 1 - Critical Adapt merge to the new IO Handler
implementation
Rejected:
-------------
PF9100124518 2 - Major DOD6 doors: elevator blocked regularly without
visible reason
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
This release contains all changes from V9.6.04.
V9.7.02
--------
Delivered (d/m/y):30/03/2009
PC/NT : S00x.exe, 8,056,879 bytes
N/A
- New functionality: -
----------------------
PF9100124704 3 - Average LOP Teaching Feedback display on HMI
PF9100139819 3 - Average Installation ID stored in LOPs
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100139915 2 - Major LOP Scan at startup does not read the IO
configuration for a BIO2 master node on side 2
PF9100081176 3 - Average Support Monitoring values from -99999 up to
99999
PF9100081169 3 - Average TWB over RS232 communication problem
PF9100124609 3 - Average LOP with wrong configuration reports
continuosly Node dead
PF9100124376 4 - Minor wrong behaviour of MR when CF22 PA41=02
Improvement
-------------
PF9100081179 3 - Average indexQueue problem on Windows Platform
PF9100081181 3 - Average Build speed up for Windows Platform
PF9100081180 5 - Enhancement Support COP hardware id on Windows
Platform
PF9100081173 5 - Enhancement Extend CF26 for 75m
PF9100139922 5 - Enhancement GIH: OPT Refactoring: remove the IO
handler task
PF9100139923 5 - Enhancement GIH: OPT Integrate the signalisation of
the shaft devices (LOPs)
PF9100139792 4 - Minor Bio2 secure input on side2 - contiuous BioBus-
Reset for V9.7.02
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
This release contains all changes from V9.6.02.
V9.7.01
--------
Delivered (d/m/y):26/02/2009
PC/NT : S00x.exe, 8,044,591 bytes
N/A
- New functionality: -
----------------------
PF9100124539 3 - Average The KSE information display is no longer
working
PF9100124533 3 - Average 75m Shaft Extension: Extension EEPROM file
PF9100124535 3 - Average 75m Internal IFs extansion (2 to 4 bytes)
PF9100124534 3 - Average 75m Interface FC Implementation
PF9100124546 3 - Average Installation ID stored in LOPs
PF9100081165 5 - Enhancement Controller adaptations for new WinSim
PF9100081160 5 - Enhancement TWB over RS232
PF9100124416 3 - Average Extended data for ELEVATOR_DIAGNOSTIC_CALL V9.7
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100081164 2 - Major Long filenames for binaries not working for
some length
PF9100124394 3 - Average SCPU bootloader, SMIC6x CPLD programming via
MMC does not work
PF9100124488 3 - Average DI2: EDEM test Distance reported wrongly
PF9100124634 3 - Average ETM: servitel message length is wrong for the
error Watchdog Reset 9.7
PF9100124610 3 - Average Correct phone numbers in SW release V9.7
PF9100033903 3 - Average Learning Travel: Elevator finish learning
correctly but remain in Waiting for deactivation
PF9100124503 3 - Average DI2: EDEM test BIOBUS: MR nodes sent as BIO1
instead of BIO2
Improvement
-------------
PF9100124545 3 - Average LOP Teaching Feedback
PF9100081161 4 - Minor Remove build warnings win platform
PF9100081158 5 - Enhancement Platform information
PF9100081159 5 - Enhancement Learning trip extension for 75m
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
This release contains all changes from V9.5.09.
V9.51.11
--------
Delivered (d/m/y):04/02/2009
PC/NT : S00x.exe, 8,015,919 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100083294 2 - Major SEM Evacuation not working
PF9100124519 3 - Average correction on floor has high priority than STOP
IN CAR
Improvement
-------------
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
This release contains all changes from V9.5.09.
V9.6.04
--------
Delivered (d/m/y):29/05/2009
PC/NT : S00x.exe, 8,073,263 bytes
N/A
- New functionality: -
----------------------
PF9100083365 2 - Major SUET_ERROR4_OVERBRIDGED_WITHOUT_ACTIVATION
PF9100124845 3 - Average AX: New Input/Output support
PF9100124980 3 - Average RESUBMITTED:correction on floor has high
priority than STOP IN CAR
PF9100124958 4 - Minor Wrong indication on HMI when elevator detected
Minimum Oil Level.
Integration tests:
------------------
PF9100124976 1 - Critical Elevator blocked due to conflicting TSD
and automatic HW evacuation on V9.6
PF9100124973 3 - Average after power off/on MENU "133" change from 1 to
0
PF9100124959 4 - Minor Minimal Oil Level active,DTO is Enable,SUMC and
RVRT Disable.
Bugfix Corrected:
-------------
PF9100083332 1 - Critical BX open loop: no recovery after FC fault
-> Elevator blocked
PF9100083335 1 - Critical BX open loop: automatic evacuation always
fails
PF9100034946 2 - Major Fire service BR1 standard. Light curtain
reopens the door.
PF9100124724 2 - Major RESUBMITTED:All BRx: problem with activation
phase with RPHT on startup (resolved only for B5)
PF9100124915 2 - Major Biobus failure (rollback)
PF9100124963 2 - Major Check Carlight sensor test duration, when
automatic carlight time is shorter
PF9100125017 2 - Major Missing ECU HB to COP: service doesn't recover
PF9100124460 3 - Average after OVERLOAD-FULL LOAD-PA or JRV ,ZBC2 is
disable
PF9100124742 3 - Average Door heartbeat error (fatal) is logged many
times
PF9100124771 3 - Average during teaching DTO are disable with AUTOMATIC
DOOR
PF9100124899 3 - Average DOOR_MAX_LOCK_TIME reported wrongly after fatal
PF9100124910 3 - Average RESUBMITTED:correction on floor where
restricted is configurated ,DTO works
PF9100124924 3 - Average RESUBMITTED:RPHT -M with parking generate Wrong
indication in the errorlog
PF9100124951 3 - Average The floor call simulation is not working
PF9100124961 3 - Average Releveling is performed when Low Oil Level KOL-
M BMK is Active.
PF9100124967 3 - Average Elevator enter in fatal error After Minimal Oil
level doesn't perform parking to lowest floor.
PF9100124974 3 - Average Allow the usage of spaces in SVID menu (CF21
PA1 e PA2)
PF9100124989 3 - Average Overload at Startup is not Detected.
PF9100125040 3 - Average after power OFF/ON ,elevator disable restricted
access via COP 5
Improvement
-------------
PF9100124880 3 - Average ZBC2 - Position of the COPH (Card reader) in
case of 2 (Two) COPH in Car
PF9100124930 3 - Average RESUBMITTED:dead and alive node(SLCUX-MR) LOP
CHECK is absent for OUTPUT LAMP
PF9100124957 3 - Average ZBC2 : Wrong Beaviour when function is disable.
PF9100124966 3 - Average Implement the overbridging during correction
with fully manual doors
PF9100124971 3 - Average Implement the overbridging during synchro with
fully manual doors
PF9100124975 3 - Average The RLC timer min value is 1 minute again on
V9.6
PF9100125024 3 - Average Car calls don't work during the Call Simulation
with certain COPs
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
This release contains all changes from V9.5.09.
V9.6.03
--------
Delivered (d/m/y):08/05/2009
PC/NT : S00x.exe, 8,060,975 bytes
N/A
- New functionality: -
----------------------
PF9100123793 3 - Average BX: support for several new door types
PF9100124592 3 - Average BXCCL: Minimal Oil Level (MOL) - elevator
behavior in case of MOL
PF9100124834 3 - Average CLC type switch confirmation implementation
PF9100124837 3 - Average Multiple calls on parallel card reader
Implementation
PF9100124842 3 - Average Blocked Car system detection Implementation
PF9100124843 3 - Average Blocked Car system detection HMI
Integration tests:
------------------
PF9100124854 4 - Minor during fire evacuation on CADI there is an
information about level of evacuation floor
PF9100081194 5 - Enhancement Support new WinSim for V9.6
Bugfix Corrected:
-------------
PF9100124603 2 - Major people trapped in fire service with SDIC RESET
PF9100124749 2 - Major Elevator in AAT- Wrong behaviour
PF9100124851 2 - Major Elevator is Blocked After SDIC Reset in
Firefighter Mode.
PF9100081189 3 - Average Initialization problem KSE_UD shaft with
magnets (setting BMK codes for SIAO)
PF9100083330 3 - Average KL-M (minimal load contact) on COPH not working
PF9100101833 3 - Average KTC open during pretorque elevator blocks
PF9100124604 3 - Average CLC recalibration + DOD4: during CLC
recalibration the car is in overload
PF9100124625 3 - Average CF 16 PA 21 is not visible on SW 9.51.11 - BX
PF9100124657 3 - Average Elevator in FF mode after Sdic Reset don't
exexcuted syncrotrip ( JNFF Deactivated )
PF9100124770 3 - Average Unexpected reset
PF9100124785 3 - Average Elevator is blocked when executed Correction
trip and JAB gets Active.
PF9100124790 3 - Average invisible parameters on CF 16
PF9100124795 3 - Average DI2: malfunction of ISPT monitoirng ?
PF9100124822 3 - Average CLC type switch blocked at learning trip
PF9100124862 3 - Average dead and alive node(SLCUX-MR) LOP CHECK is
absent for OUTPUT LAMP
PF9100124895 3 - Average Wrong Messages during position trip:
FC_CMD_CORRECT_ACTUAL_POSITION_ERROR 0x5555 0x0000 0x5555
Improvement
-------------
PF9100124873 2 - Major Car light sensor backward compatibility
PF9100123651 3 - Average system info does not decode car iostatus (V9.6)
PF9100124751 3 - Average wrong parameter CF2 PA8
PF9100124791 3 - Average SW internal, synchro: move logic from services
(synchro service) to car controller ( synchro job)
PF9100081188 5 - Enhancement Extend platform information with display
type
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
This release contains all changes from V9.5.09.
V9.6.02
--------
Delivered (d/m/y):26/03/2009
PC/NT : S00x.exe, 8,024,111 bytes
N/A
- New functionality: -
----------------------
PF9100124679 3 - Average SDIC42 HW ID identifier
PF9100124532 3 - Average SDICAX HW ID identifier
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100124638 2 - Major Elevator blocked due to Biobus failure 9.6
PF9100139917 2 - Major LOP scan at startup gets stuck if the node does
not answer
PF9100124642 3 - Average <GFAT> after a Fatal error outside door zones a
DOOR_CMD open is sent by controller
Improvement
-------------
PF9100124474 3 - Average SimCard: if Simcard is defected and FC is not
commissioned HMI remain blocked
PF9100121965 3 - Average System_info: show_lop_state are recorded twice
PF9100033524 3 - Average is not possible to erase the MR nodes, CF40
LE91..93 PA99 is not visible
PF9100124601 3 - Average NS21+EBR1 or LIFD strange behavior on EBR1
floor or BLIND FLOOR
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
This release contains all changes from V9.5.09.
V9.6.01
--------
Delivered (d/m/y):06/03/2009
PC/NT : S00x.exe, 8,020,015 bytes
N/A
- New functionality: -
----------------------
PF9100124562 3 - Average BXRel5: Support drive Omar soft start (HYD)
PF9100083295 6 - not applicable SMICAX support
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100083276 1 - Critical Dynahyd does not work with SMIC32
PF9100083303 1 - Critical Synchro Trip blocked with door type 6
(QKS11), door type 11 (Varidor 10E)
PF9100083095 2 - Major FA/open loop: any command leads to a synchro
trip
PF9100083283 2 - Major SMIC32 + SDIC41 QA/QB: LUET signal not
correctly supported
PF9100124496 2 - Major after fire service door overtemp. ignored
PF9100083298 3 - Average Copy paste error in correction service
PF9100124463 3 - Average All BRx: problem with activation phase with
RPHT on startup (resolved only for B5)
PF9100124521 3 - Average DI2: EDEM test BIOBUS: MR nodes sent as BIO1
instead of BIO2
PF9100124587 3 - Average BXCCL: NS21 Bug - The signal REFE1 (BMK 173)
does not work
PF9100124589 3 - Average BXCCL: Signalization bug - LBFC is not active
during BR1 if set on CANIO or SAIO
PF9100124591 3 - Average BXCCL: Signalization bug: LRVC and LNOC are not
working with SCOPHMH3.Q
PF9100124611 3 - Average Correct phone numbers in SW release V9.6
PF9100124685 3 - Average ETM: servitel message length is wrong for the
error Watchdog Reset 9.6
PF9100124694 3 - Average ETM: Access Violation im SSL
PF9100124423 4 - Minor after learning with menu 116 elevator remain
in Learning waitingForDeactivation
PF9100124686 4 - Minor Reset information is not stored in assert table
Improvement
-------------
PF9100124666 2 - Major Add Car light sensor status to system info
PF9100102099 3 - Average Implement procedure for LOP configuration even
without DTO button
PF9100124510 4 - Minor SRAM: Add SW internal information to debug SRAM
problem
PF9100124650 2 - Major 1: DOD6 doors: elevator blocked regularly
without visible reason
PF9100083291 2 - Major DOD6 doors: elevator blocked regularly without
visible reason
PF9100124608 3 - Average Extended data for ELEVATOR_DIAGNOSTIC_CALL V9.6
PF9100139793 4 - Minor Bio2 secure input on side2 - contiuous BioBus-
Reset for V9.6.01
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
This release contains all changes from V9.5.09.
V9.51.10
--------
Delivered (d/m/y):15/01/2009
PC/NT : S00x.exe, 8,015,919 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100083284 2 - Major E_DOOR_SHAFT_ERROR: door keeps being
unavailable
PF9100124428 2 - Major wrong behaviour of BR2-SG-A with JBF-A
PF9100124367 3 - Average CF_DUMP: not always completed correctly, then
CF is blocked due to device logged in
PF9100124440 3 - Average information about the CANIO boards is not
included in the system_info.
PF9100123214 3 - Average SHBT activation: LAB and Buzzer on COP shall be
activated
PF9100124387 3 - Average wrong behaviour of correction in FULL LOAD
PF9100083240 3 - Average closed loop + fully manual doors => index Queue
assertion
PF9100124479 3 - Average E_ELEVATOR_STARTED_UP is not visible in RMCC
9.51
Improvement
-------------
PF9100083262 3 - Average EEPROM conversion for V9.51, before the next KA
version
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
This release contains all changes from V9.5.09.
V9.51.09
--------
Delivered (d/m/y):17/12/2008
PC/NT : S00x.exe, 8,011,823 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100083230 1 - Critical Elevator in Smokedetector after Overload
return in Normal mode.
PF9100083244 1 - Critical Elevator in Smokedetector after RESET
return in Normal mode.
PF9100083004 2 - Major SEM doors not opened at the end of the
evacuation
PF9100083145 2 - Major CL+Relev+DOD4: assertion in CMC
PF9100083147 2 - Major CL+Relevel+DOD4: Elevator blocked (2nd)
PF9100083149 2 - Major CL+relevel+DOD4: Synchronisation instead of
Relevelling
PF9100134803 2 - Major BR2-SG-A fire service there are problem with
deactivation of KSKB
PF9100082392 3 - Average SHBT + Synchronisation Trip + door type 59,60
=> door lock released
PF9100123998 3 - Average ZBC2 Must also work with the combination of two
COPH
PF9100124045 3 - Average at START-UP in sprinkler elevator make syncro
PF9100124305 3 - Average ETM: protocol defines 4 bytes for the set next
call timer but only the last 2 are used by controller
PF9100124365 4 - Minor SW CR: probably wrong include in
outputTable.hxx and in inputTable.hxx
PF9100124368 4 - Minor SW CR: wrong include in Smic6ViewFactory?
PF9100124370 4 - Minor SW CR: serPoMgr wrong port handling
PF9100124361 4 - Minor remote configuration: is not possible to set
value "0" on CF1, it takes "00"
Improvement
-------------
PF9100083222 3 - Average Msgs send in serviceExec to the Services,
Firefighter State (04) improvement
PF9100124362 3 - Average Wrong CLC default value for BX
PF9100124008 3 - Average SW INTERNAL: Service manager should not touch
the reference count of messages
PF9100081155 3 - Average Reslove rebase problems
PF9100083126 2 - Major closed loop + fully manual doors => elevator
blocked with or w/o fatal error
PF9100124064 3 - Average no DI2 for BX
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
This release contains all changes from V9.5.09.
V9.5.09
--------
Delivered (d/m/y):11/12/2008
PC/NT : S00x.exe, 8,015,919 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100124371 2 - Major Biobus: MR nodes can not be detected and
configured
PF9100124358 4 - Minor Minor changes related to advanced log
Improvement
-------------
PF9100124353 3 - Average Terminal command used for call simulation
doesn't work with independent control (used for test only)
Rejected:
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.5.08
--------
Delivered (d/m/y):04/12/2008
PC/NT : S00x.exe, 7,011,823 bytes
N/A
- New functionality: -
----------------------
PF9100081138 3 - Average Addvanced Logging and Error Backtrace
PF9100081140 3 - Average Persistent entry to enable/disable Advanced
Error Logging
PF9100081149 3 - Average Automatic LOP count for terminal device
PF9100124300 3 - Average Support of SCOP4B_EU_12 pcb
PF9100124338 3 - Average Support of SCOP4B_EU_12 pcb (second COP)
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100123687 1 - Critical DI2-Elevator blocked in fatal error
without justfied reason
PF9100124295 1 - Critical Diagnostic call message leads to
overwrite of the small msg array
PF9100124322 1 - Critical Elevator in Smokedetector after Overload
return in Normal mode.
PF9100081145 2 - Major WinSim startup probelm with Pipes - problem on
controller side
PF9100124272 2 - Major EDEM 2nd part, NODE_DEAD reported on RMCC
PF9100124296 2 - Major RESUBMITTED: Belt Monitoring Trip - Wrong
travelspeed
PF9100033989 3 - Average COP Domino ( CF 15 ) : is not possible assigned
a floor to star botton.
PF9100081148 3 - Average CF_DUMP level info missing
PF9100083211 3 - Average configuring-problem if immediately done after
LC
PF9100083220 3 - Average DI2: EDEM message for door wrongly logged (SW
internal)
PF9100102170 3 - Average TSD: during power up, if a SDIC reset occurs
the elevator remain blocked
PF9100124049 3 - Average RESUBMITTED:Wrong indication of HMI after CAN
disconnection and restart
PF9100124228 3 - Average CF12 PA4 shows wrong SW version for SEMP
PF9100124259 3 - Average CF16 PA32 wrong parameter value
PF9100124263 3 - Average AMA: alarm circuit discriminator is disturbed
by out of group service
PF9100124264 3 - Average GFAT error table updated according to C4 open
items
PF9100124269 3 - Average RPHT ERROR reported wrongly
PF9100124294 3 - Average 2:) A msg is not released if the SIM card is
not present
PF9100124301 3 - Average RESUBMITTED: ETM Procits SCH1-080165
PF9100124303 3 - Average 2:) ISPT-M: Elevator Status 44 is not sent to
RMCC
PF9100124344 3 - Average EDEM: resource Elevator, error
E_ELEVATOR_SAFETY_CHAIN contains wrong data
PF9100124265 4 - Minor HMI shows entries for MR-nodes MR1,2,3 even if
not connected
PF9100124333 4 - Minor EDEM: SW comments are not 100% correct
PF9100124081 5 - Enhancement DI2: change the RLC timeout
Improvement
-------------
PF9100081147 2 - Major Remove sending messages from Services
PF9100083226 3 - Average Msgs send in serviceExec to the Services,
Firefighter State (04) improvement
PF9100124240 3 - Average DI2: add additional information to w-dog reset
PF9100124273 3 - Average Terminal command to activate the reservation
service (used for FC test only)
PF9100124306 3 - Average DI2: diagnostic call msg can be extended with
the reason of the call
PF9100124356 3 - Average E_DOOR_SHAFT_ERROR throw a fatal after 5
occurrences within 1h
PF9100081152 4 - Minor Cleanup Advanced Logging
PF9100083228 6 - not applicable SW-internal: Error-number cleanup
Rejected:
-------------
PF9100083221 DI2: wrong default value for CF22 PA1 (Bionic5)
PF9100123644 DI2 Missing cop devices is undetected
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.5.07
--------
Delivered (d/m/y):14/11/2008
PC/NT : S00x.exe, 7,979,055 bytes
N/A
- New functionality: -
----------------------
PF9100033875 2 - Major Belt Monitoring Trip - Wrong travelspeed
PF9100083210 3 - Average DI2-EDEM doors: additional info on door error
recovery
PF9100124238 3 - Average 5. DI2 Improvement - Car light monitoring
(RLCSM & RLCM)
PF9100124246 3 - Average DI2 Add the timer for a stop situation at
startup
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100124226 1 - Critical DI2-Elevator blocked due to wrongly
detected E_TRIP_PHSx_SIGNAL_PERSISTENTLY_BRIDGED
PF9100124232 1 - Critical DI2: GFAT, error during evacuation not
correctly handled
PF9100033527 2 - Major NS 21. After Power OFF Power ON Elevator is
Blocked.
PF9100083184 2 - Major EDEM 2nd part, NODE_DEAD reported on RMCC
PF9100124124 2 - Major Elevator is blocked due to missing fault
detection; THMH (DRIVE_OVERTEMP)
PF9100081142 3 - Average CF_DUMP causes assert
PF9100102081 3 - Average BioBus: after dead->alive transition input-
image at BioNodes is not consistent with input-image at SCIC
PF9100124211 3 - Average Startup (91) not logged in bionic 5.4
PF9100124212 3 - Average ETM Procits SCH1-080165
PF9100124222 3 - Average Message created but not sent in Fire Service
PF9100124233 3 - Average SW bug in
CCAlarmSupervisor::updateFromCarController
PF9100124261 3 - Average missing recorded E_ELEVATOR_COP_HB_MISSING
after start-up
PF9100124151 3 - Average ISPT-M: Elevator Status 44 is not sent to RMCC
PF9100124224 4 - Minor RESUBMITTED: RIB switch off when Schoolhouse is
active
PF9100124227 4 - Minor ETM: hack in embedded protocol is not needed
anymore
PF9100124235 5 - Enhancement Domino keyboard via terminal: added some
messages on terminal
Improvement
-------------
PF9100081136 3 - Average Change UserLevel for CF41
PF9100081137 3 - Average Improve EDEM FC
PF9100081141 3 - Average Improve startup operation state
PF9100123766 3 - Average Improvement in duplex ID exchange
PF9100081143 4 - Minor Improvement visibility CF22 & 23
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
This version received merge from V9.40.01 and V9.39.05
V9.5.06
--------
Delivered (d/m/y):30/10/2008
PC/NT : S00x.exe, 7'974'959 bytes
N/A
- New functionality: -
----------------------
PF9100123849 3 - Average DI2: Extended messaging (EDEM) resource FC
PF9100123850 3 - Average DI2: Extended messaging (EDEM) resource TRIP
PF9100124153 3 - Average DI2: Test trip is not executed due to "notify
normal state call"
PF9100124173 3 - Average 4. DI2 Improvement - Car light monitoring
(RLCSM & RLCM)
PF9100124191 3 - Average DI2:Notification Error default value Not
parametrizable with CF23
PF9100124192 3 - Average Disable visibility: Set Volume Gong level at
each floor (LA) - biobus
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100123723 1 - Critical DI2-Elevator blocked due to wrongly
detected E_TRIP_PHSx_SIGNAL_PERSISTENTLY_BRIDGED
PF9100124005 1 - Critical DI2:elevator blocked after startup
possibly due to thunderstorm
PF9100083182 2 - Major EDEM-BioBus 2nd part
PF9100123784 2 - Major Elevator in INSPECTION travel over KNE
PF9100123910 2 - Major emergency trip (NS21) doesn't start in FF
elevator blocked
PF9100124127 2 - Major DI2: Alarm without answer reduction (AMA1 &
AMA2), Advanced alarm filtering is never possible.
PF9100124148 2 - Major RPHT- M Does not trigger RMCC Call
PF9100071223 3 - Average SUMC only sound two times when final timer
active
PF9100081135 3 - Average CF_START, CF_DUMP login problem
PF9100083132 3 - Average LOPM key input on XBIO is not configurable
(CF40 LE.. PA21 is not available)
PF9100083191 3 - Average DI2-RPHTM fixes for dev test findings and
cleanup
PF9100083196 3 - Average show_lop_state does not show node-dead/alive
correctly
PF9100123636 3 - Average fire is active the evacuation floor becomes the
Fire Recall floor
PF9100123789 3 - Average COP DOMINO Configuration is not possible with
SW 9.5.01
PF9100124116 3 - Average Declassify error E_DOOR_SHAFT_ERROR in
controller
PF9100124121 3 - Average RESUBMITTED: RMCC - not elevator status after
Technician left site
PF9100124123 3 - Average RESUBMITTED: Is not possible to know the FC
commissioning number (CF16PA50 missing)
PF9100124130 3 - Average CF_DUMP shows only a few CF
PF9100124147 3 - Average Extended voice announcer for KOREA do not
announce in case of JBF
PF9100124164 3 - Average Duplex: Group call not correclty initialized
at startup
PF9100124167 3 - Average Overload:Notification call not performed after
120 sec
PF9100124170 3 - Average Battery: Error continuously logged
PF9100124171 3 - Average SDIC connection missing elevator blocked in
startup witjout error
PF9100124178 3 - Average Ui: update at startup
PF9100124201 3 - Average DI2 - defualt values
PF9100134751 3 - Average Ext. Voice announcer: Travel direction is not
annouced if relevelling is performed.
PF9100135902 3 - Average All BRx: problem with activation phase with
RPHT on startup
PF9100123848 3 - Average DI2: Extended messaging (EDEM) resource CLC
PF9100124057 4 - Minor RESUBMITTED - ISCPU - DIP. 6 ON elevator not in
configuration
PF9100124154 4 - Minor ERR LED on SMIC 61 still blinking after RPHT
failure
PF9100124156 4 - Minor RESUBMITTED: RIB switch off when Schoolhouse is
active
PF9100132798 4 - Minor CF12 PA4 shows wrong SW version for SEMP
PF9100134749 4 - Minor BR2 FR Wrong indication of HMI when Elevator is
in Overload
PF9100124184 5 - Enhancement COP AP: domino keyboard only on first COP
Improvement
-------------
PF9100123943 1 - Critical DI2 Elevator goes in Fatal error for
likely wrong condition
PF9100083186 2 - Major ACK on all address-ranges after LOPs swithced
by SBBD
PF9100081133 3 - Average Support Recall Service for Belt Monitoring Trip
PF9100082999 3 - Average UNDO: remove log of E_BIOBUS_NODE_DEAD
PF9100123846 3 - Average DI2: Extended messaging (EDEM) resource DOOR
PF9100124172 3 - Average ServiceCopHeartBeatError : reset Cop every 60
sec until service still active
PF9100124174 3 - Average Assert: missing LOG information
PF9100083190 4 - Minor JBF-A don't work on machine room LCUX node
PF9100083193 4 - Minor Possibility to RESET the SCIC via the
Inspection Panel
PF9100123561 4 - Minor learning trip delete a domino configuration
(CF15)
PF9100124135 4 - Minor Improvement of the trip counter management
PF9100124074 5 - Enhancement De-classify the log entry
ELEVATOR_STARTED_UP
PF9100124190 5 - Enhancement Rename error codes of AMA
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
This version received merge from V9.40.01 and V9.39.05
V9.5.05
--------
Delivered (d/m/y):07/10/2008
PC/NT : S00x.exe, 7'929'903 bytes
N/A
- New functionality: -
----------------------
PF9100083173 3 - Average DI2-RPHTM missing features and cleanup
PF9100123729 3 - Average DI2: Diagnostic Improvement HMI (for all)
PF9100123854 3 - Average DI2: Extended messaging (EDEM) resource BIOBUS
PF9100123897 3 - Average DI2: Extended messaging (EDEM) fourth part
PF9100124009 3 - Average 2. DI2 Improvement - Car light monitoring
(RLCSM & RLCM)
PF9100124090 3 - Average 3. DI2 Improvement - Car light monitoring
(RLCSM & RLCM)
PF9100124112 3 - Average DI2: Graceful fatal error (GFAT)
enabling/disabling with HMI
PF9100123845 3 - Average DI2: Extended messaging (EDEM) resource
ELEVATOR
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100071248 2 - Major certain car call could not be registered unless
in RV service
PF9100124001 2 - Major E_DOOR_NO_ERROR wrong class type (R or F)
PF9100071235 3 - Average VCA: The announcement for travelling direction
is wrong in some special cases.
PF9100098462 3 - Average Bionic 5 duplex: Pending Floor calls canceled
when other Elevator starts up
PF9100083144 3 - Average SMIC32: wrong default load sensor type
PF9100101633 3 - Average Battery check: each 10min the battery low error
is logged
PF9100122116 3 - Average EB - Deactivation HMI shows wrong door status
PF9100123690 3 - Average ZB_ZLA: High prio service is actives then JKLBL
went active, shool house service never invoked.
PF9100123757 3 - Average ETM: prefix and phone number remote
configuration, comma isn't accepted
PF9100123824 3 - Average wrong voice annoncer of floor in FF with BR3
KR,and in reservation
PF9100123921 3 - Average COP25 Button AP/EU button assignment not fully
visible in system info
PF9100123946 3 - Average Is not possible to know the FC commissioning
number (CF16PA50 missing)
PF9100124048 3 - Average RESUBMITTED:Sprinkler recall NZ- output fire
indicator (LEF) doesn't lit
PF9100124053 3 - Average CF15 not possible
PF9100124063 3 - Average A msg is not released if the SIM card is not
present
PF9100132796 3 - Average LAB is switched OFF in case of stop button is
pressed
PF9100081132 3 - Average CF03 PA3 not updated in EEPROM
PF9100102035 4 - Minor VCA,floor announced two times if fire activated
on deceleration
PF9100123566 4 - Minor CF DUMP generate an assertion
PF9100123773 4 - Minor RIB switch off when Schoolhouse is active
PF9100133060 4 - Minor wrong number of key in CF 5
PF9100133103 4 - Minor preopenig doesn't work when PA1 is active
Improvement
-------------
PF9100124051 2 - Major V9.5 should wok on SCIC5
PF9100081126 3 - Average CF21 should not be visible on SCIC3 and SCIC5
PF9100081128 3 - Average EEPROM conversion for V9.5
PF9100081131 3 - Average Menu visibility handling (pcare and terminal)
PF9100083153 3 - Average asymmetric duplex - CF86PA01 shall not exceed
MaxNbrOfFloors
PF9100083161 3 - Average seperate initializeServiceTrigger from start of
nodeMonitoring
PF9100124062 3 - Average DI2:AMA functionality to check
PF9100083155 5 - Enhancement SW-internal: refactoring of node
monitoring
PF9100123564 5 - Enhancement On system info missing information about
Blind Floor level
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
This version received merge from V9.40.01 and V9.39.05
V9.5.04
--------
Delivered (d/m/y):16/09/2008
PC/NT : S00x.exe, 7'888'943 bytes
N/A
- New functionality: -
----------------------
PF9100123738 3 - Average DI2: Cop HB Recovery service
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100124011 1 - Critical Messages leak problem
PF9100124021 1 - Critical Messages leak problem (II)
PF9100124015 3 - Average DI2: COP HBs (COPHB) (part3: design and
bugfixes)
PF9100124019 3 - Average AMA: bugfixes after second test
Improvement
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
This version received merge from V9.40.01 and V9.39.05
V9.5.03
--------
Delivered (d/m/y):05/09/2008
PC/NT : S00x.exe, 7'880'751 bytes
N/A
- New functionality: -
----------------------
PF9100081122 2 - Major ISPT monitoring (ISPT-M)
PF9100083158 3 - Average New Fire Service state for firefighter
PF9100083160 3 - Average BR3BE, with Smoke Detector for machine room
less elevators
PF9100123730 3 - Average DI2: Car light monitoring (RLCSM & RLCM)
PF9100123732 3 - Average DI2: Graceful fatal error (GFAT)
PF9100123733 3 - Average DI2: Notification of blocking errors (BSN)
PF9100123734 3 - Average DI2: RPHT monitoring Without Final Timer
(RPHTM)
PF9100123737 3 - Average DI2: RPHT monitoring With Final Timer (RPHTM)
PF9100123741 3 - Average Belt Monitoring Trip
PF9100123829 3 - Average DI2: COP HBs (COPHB) (part2: log and design)
PF9100123831 3 - Average DI2: Extended messaging (EDEM) third part
PF9100123918 3 - Average RESUBMITTED: LINV51: add new input
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100123909 2 - Major BR1 EN81-73 Type C: wrong KBF behaviour
PF9100081120 3 - Average CADI makes login when already connected at
startup
PF9100083165 3 - Average SW-internal - compile microtec SCIC5
PF9100123666 3 - Average India report on wrong voice announce in
attendat service and main floor "g"
PF9100123915 3 - Average HMI display wrongly handled
PF9100123917 3 - Average Wrong indication of HMI after CAN
disconnection and restart
PF9100123972 3 - Average Extended information for message
E_ELEVATOR_DIAGNOSTIC_CALL
PF9100123992 3 - Average AMA: bugfixes after first test
PF9100071236 4 - Minor VCA: AutoReset for announced floor 14 or 17. No
announcement for alarm and RNO
Improvement
-------------
PF9100123844 3 - Average CADI baud rate improvement second part (debug
command added)
PF9100083157 4 - Minor BX needs at Startup more msg buffer size
PF9100123899 4 - Minor SDIC Preannounce door open
PF9100123966 3 - Average Integration of Ricci delivery, merge needed
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
This version received merge from V9.40.01 and V9.39.05
SCIC Software Pair:
---------------------------------------
This version is tested to work with the following releases:
-------------------------------------------
Bootloader | V1.4
FC(CXS) | Deli 61 or Deli 68
FC(NXP) | 3.34
Yaskawa | 290
SEM | V2.0.05
BBCtrl | V4.1.02 (4.1 - KA)
CPLD (ISCPU) | V1.08
CPLD (SMIC6) | V1.08
COP1 | KA
COP2 | KA
COP3 | V2.1
COP3A | V3.0.15 (KA)
COP4 | V2.3.00
COP4ZLA/EU | V2.3.00
COP5 | V3.0.02
COP5AP | V1.3.03
COP5NA | V1.1
COPH | V2.1
COPH3 | V3.3.02
COPMAT | V3.3.02
CANIO | V1.1.01
SDIC2 | X
SDIC3 | X
SDIC3A | V2.5.04
SDIC4 | V2.5.04
SDIC41A | V3.1.05
SDIC5 | V2.5.00
SDIC53 | V2.5.00
SLCU-M | V2.1.03
SLCU2-M2| V2.1.03
SLCUx | V2.1.03
PSI | V2.1.01
SLCU-MX | V2.1.01
SLOPM2 | KA
SLINV5 | V1.1
SLOPE(L)51 | V1.5.01
SLOPE52 | V1.5.01
SLOPB4 | V1.5.01
SLOPBL41 | V1.5.01
SLOPEB52 | V1.5.01
SLOPBL42 | V1.5.01
SLOPDMA5 | V1.5.01
SLINK5 | V1.5.01
SLOPNA51/53| V1.5.01
SLOPNA52/54| V1.5.01
SLOPEBH5 | V1.5.01
SPECI | V1.31.6 8.01.2008
CADI | V2.92
CLSD | V1.4.11
Simcard | Filesystem V6
ACVF | V4
-------------------------------------------
x = NOT compatible
KA = look latest KA software available for that device
V9.5.02
--------
Delivered (d/m/y):04/08/2008
PC/NT : S00x.exe, 7'778'351 bytes
N/A
- New functionality: -
----------------------
PF9100123836 3 - Average Enable visibility: Set Volume Gong level at
each floor (LA) - biobus
PF9100123736 3 - Average DI2: Alarm without answer reduction (AMA1 &
AMA2)
PF9100123739 3 - Average DI2: COP HBs (COPHB)
PF9100123670 3 - Average LINV51: add new input
PF9100083135 3 - Average Fire Service with multiple levels (JBFH1,
JBFH2, KBFH1, KBFH2)
PF9100123818 3 - Average DI2: Extended messaging (EDEM) second part
PF9100123721 3 - Average Equipment number: support 11 digits
PF9100123731 3 - Average DI2: Extended messaging (EDEM)
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100083136 2 - Major HYD: E_DOOR_SHAFT_ERROR on first door opening
PF9100133066 2 - Major wrong behaviour in FF of elevator after power
failure
PF9100133055 2 - Major KTHM overtemperature is active forever
PF9100122810 3 - Average Door opening/closing error after automatic
evacuation trip
PF9100123755 3 - Average Door Reversing Canceling Car call
PF9100123480 3 - Average with SAFETY CHIAN open/close RPHT is active in
FIRE SERVICE
PF9100132291 3 - Average RMCC - not elevator status after Technician
left site
Improvement
-------------
PF9100081117 2 - Major Speci re-factoring step2
PF9100081116 3 - Average Speci re-factoring
PF9100132284 3 - Average wrong LOP/COP show display in schoolhouse
service
PF9100123240 3 - Average CADI baud rate improvement
PF9100123674 3 - Average 2: Handle the new features and feedbacks from
the new CLSD version
PF9100133031 3 - Average SCIC5: LOP count triggers CPU32 Exception: Adr
error
PF9100133059 3 - Average Elevator make a reset after Learning
trip,display don't show learning ( 59 )
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
This version received merge from V9.40.01 and V9.39.05
V9.5.01
--------
Delivered (d/m/y):02/06/2008
PC/NT : S00x.exe, 7'721'007 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100122951 3 - Average After over temperature elevator doesn't travel
in inspection mode
PF9100123693 3 - Average ACID display: wrong Car call acknowledge
PF9100123472 3 - Average EBR1, elevator calls blocked after floor on
fire activation
PF9100123572 3 - Average deactivation of firefighter isn't in any floor
with BR3 AU type B
PF9100123503 3 - Average Out of service can not be dectivated (in
duplex)
PF9100123585 3 - Average ISCPU: reconnect CAN after start-up, elevator
doesn't recover
PF9100132544 3 - Average Elevator goes in fatal error after two door
Heart Beat error
PF9100123711 3 - Average Winsim startup: no elevator status shown at
startup
PF9100123177 4 - Minor CF_START: CF40 can not be configured by CF:=
command
PF9100123484 4 - Minor RESUBMITTED: Over temperature time increased to
10 minutes
PF9100123673 3 - Average Pre-Release V9.5.00: Ricci integration of SW
components and operating system changes
Improvement
-------------
PF9100123006 3 - Average Serial port change on controller to use USB
PF9100083121 3 - Average Support for SMIC32
PF9100083120 3 - Average support for ISCPU on SMIC4
PF9100123685 3 - Average ETM: only 5 retries in case of message buffer
full
PF9100123319 3 - Average Elevator Operation state refactoring
PF9100101955 4 - Minor Menu 112: improvement proposal
PF9100123630 5 - Enhancement SW Components: Drive, Shaft and Trips
Packages second part
PF9100123595 5 - Enhancement SW Components: Drive, Shaft and Trips
Packages
PF9100123569 5 - Enhancement Avoid the car task watchdog reset due to
CAN blocked
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
SCIC5 doesn't show LEDs if plug on SMIC5
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
This version is based on V9.38 and V9.39
V9.40.01
--------
Delivered (d/m/y):17/07/2008
PC/NT : S00x.exe, 7'589'935 bytes
N/A
- New functionality: -
----------------------
PF9100083139 3 - Average Disable visibility: Set Volume Gong level at
each floor (LA) - biobus
PF9100123680 3 - Average Set Volume Gong level at each floor (LA) -
biobus
PF9100123775 5 - Enhancement Allow configuration of the PSI board
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100132350 3 - Average Voice Announcer Announce twice
PF9100123675 3 - Average DI2-mismatch between reported info code and
code in KID
PF9100123699 3 - Average ETM: only 5 retries in case of message buffer
full
Improvement
-------------
PF9100123709 3 - Average 2: Elevator goes in fatal error after two door
Heart Beat error
PF9100123776 5 - Enhancement Allow the pre-configuration of the cop
domino deployment
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
The CR123319 Elevator Operation state refactoring - is marked as integrated but in
fact not: the sources are integrated in V9.5 stream.
V9.39.04
--------
Delivered (d/m/y):08/07/2008
PC/NT : S00x.exe, 7,528,495 bytes
N/A
- New functionality: -
----------------------
PF9100123720 3 - Average Equipment number: support 11 digits for MOD
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100132734 2 - Major LOPM key input on XBIO is not configurable
(CF40 LE.. PA21 is not available)
PF9100123646 2 - Major correction on floor where restricted is
configurated
PF9100132930 3 - Average Simcard: Duplex with equip. 12345678-1 is not
working
PF9100083130 3 - Average LC problem with buggy FW
Improvement
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Attendant service and voice announce can work only if preopening is available.
Notes:
------
This release is based on V9.37.
V9.39.03
--------
Delivered (d/m/y):18/06/2008
PC/NT : S00x.exe, 7,524,399 bytes
COLDFIRE (SCIC 6):
SCC6_939.BIN checksum: $07F2D616
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100123604 2 - Major RPHT is enable in FIRE SERVICE
PF9100123606 2 - Major when SPRINKLER is active KSKB is disable
PF9100123608 2 - Major DOOR OPEN ON THE BLIND FLOOR (DEAD RISK)
PF9100123611 2 - Major CC are disable in FF when STOP IN CAR ON/OFF
PF9100123627 2 - Major ATTENDANT SERVICE has high priority then FIRE
SERVICE (WRONG)
PF9100132551 2 - Major Asym duplex: Floor call on Elevator with CF86
PA1 VL=2, is not working
PF9100123437 3 - Average India report on wrong voice announce in
attendat service and main floor "g"
PF9100123522 3 - Average wrong calibration of CLC with DIGISENS sensor
PF9100123605 3 - Average elevator make assertion when EBR1 is active
full load
PF9100123629 3 - Average Attendant service(LI): AN3 have low priority
but still works when LI active
PF9100123633 3 - Average LI mode wrong behaviour in FULL LOAD
PF9100123654 3 - Average wrong TDIF arrows and acknowledge while
attendant service is active (BX)
Improvement
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Attendant service and voice announce can work only if preopening is available.
Notes:
------
This release is based on V9.37.
V9.39.02
--------
Delivered (d/m/y):30/05/2008
PC/NT : S00x.exe, 7'524'399 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100083114 2 - Major Double side, the SLCUX cannot be configured
PF9100083116 2 - Major the RVR will not activated during inspection
PF9100123580 2 - Major ZB_ZLA, restricted egress: car call is not
accepted
Improvement
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
This release is based on V9.37.
V9.39.01
--------
Delivered (d/m/y):15/05/2008
PC/NT : S00x.exe, 7,524,399 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100123360 2 - Major asymmetric group - wrong Gong, LW-U, LW-D, Ack
PF9100123317 3 - Average First call leads to sync trip on BX OL
PF9100083068 3 - Average Minimal load: elevator permanently in use
PF9100083075 3 - Average minimal load (KL_M) not working correctly with
non-automatic doors
Improvement
-------------
PF9100083069 3 - Average Version V9.39, BR4HK, behavior after power
OFF/ON -> door in middle position
PF9100083103 5 - Enhancement Name for V9.39 Beta version
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
This release is based on V9.37.
V9.38.08
--------
Delivered (d/m/y):29/05/2008
PC/NT : S00x.exe, 7'659'567 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100083115 2 - Major ZB_ZLA service schoolhouse - carcall not
working
PF9100132206 2 - Major ZB_ZLA, restricted egress: car call is not
accepted
PF9100123536 3 - Average RESUBMITTED: Attendant service(LI): AN3 have
low priority but still works when LI active
PF9100123558 4 - Minor On system info missing information about CLSD
PF9100123529 4 - Minor 3.Part: Memory Leak problem with SSL
PF9100123537 5 - Enhancement Service name does not correspond to
service list
Improvement
-------------
PF9100123552 5 - Enhancement ETM: avoid that terminal blocked due to
call crash and filter duplicated lift states
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.38.07
--------
Delivered (d/m/y):20/05/2008
PC/NT : S00x.exe, 7'585,839 bytes
N/A
- New functionality: -
----------------------
PF9100123483 2 - Major SCPU: Bootloader V1.4
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100123530 2 - Major Double side, the SLCUX cannot be configured
PF9100131831 2 - Major NS21 + GUE&GLT: If RNO remain active NS21 can
not be deactivated
PF9100123508 3 - Average COP4-EU: not possible to do domino with all
keys
PF9100121829 3 - Average wrong TDIF arrows and acknowledge while
attendant service is active
PF9100123385 3 - Average Floor announce two times
PF9100071225 3 - Average Attendant service(LI): AN3 have low priority
but still works when LI active
PF9100131186 3 - Average LI mode wrong behaviour in FULL LOAD
PF9100123368 3 - Average E_TRIP_POSITION_NESTED_MOVE: during simulation
with CAN analyzer
PF9100123512 3 - Average Memory Leak problem with SSL
PF9100123526 3 - Average 2.Part: Memory Leak problem with SSL
PF9100122394 3 - Average MMC 128M and 256M, the SW doesn't start
download with only 1 reset
PF9100131555 3 - Average REFE H1 remains OFF after evacuation phase with
EN-A
Improvement
-------------
PF9100123464 5 - Enhancement ETM: remote terminal doesn't have the
feedback "SUCCESS"
PF9100123496 5 - Enhancement ETM: avoid that an invalid date always
leads to a not succesful call (ETM blocked due to SSL)
PF9100123483 5 - Enhancement SW Components: Safety Chain Controller
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Command COP_DIAGNOSTIC does not work.
Winsim have troubles on door??
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
Rejected fixes for this release:
PF9100123001, PF9100123318
V9.38.06
--------
Delivered (d/m/y):29/04/2008
PC/NT : S00x.exe, 7'614'511 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100123424 1 - Critical RESUBMITTED: Correction trip to blind
floor DT-O is enabled.
PF9100083078 3 - Average no BioBus-Check when all nodes are Bio1
Improvement
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Command COP_DIAGNOSTIC does not work.
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.38.05
--------
Delivered (d/m/y):25/04/2008
PC/NT : S00x.exe, 7'614'511 bytes
N/A
- New functionality: -
----------------------
PF9100123461 3 - Average SET_ALARM_DISCRIMINATOR_MODE command
PF9100123434 3 - Average Add all possible alarm control and diagnostics
(part 2)
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100122769 1 - Critical Correction trip to blind floor followed
by a Fatal Error
PF9100122760 2 - Major E_SHAFT_INCONSISTENT_KSE_D_U_STATE while power
return after an automatic evacuation
PF9100123273 2 - Major RESUBMITTED Automatic evacuation doesn't works
good on TSD platform
PF9100131081 2 - Major Resubmitted- PI policy- While door opened call
to current floor is accepted and served
PF9100131179 2 - Major ATTENDANT SERVICE has high priority then FIRE
SERVICE (WRONG)
PF9100083079 3 - Average show_lop_state - LOP detection display wrong
PF9100083086 3 - Average Behavior after power OFF/ON, Suspend section
PF9100123179 3 - Average GS works not correctly after out of service
PF9100123408 3 - Average RESUBMITTED: Over temperature time increased to
10 minutes
PF9100123436 3 - Average Commands to drive the HMI are no longer working
PF9100123454 3 - Average SCOPBE4 Butto star (*); return to main floor,
don't work!
PF9100123415 3 - Average P-CARE: some Parameter shall be masked (UL3)
PF9100123443 3 - Average LAB not always managed correctly
Improvement
-------------
PF9100123413 3 - Average Improve reporting on car controller listmode
PF9100123353 3 - Average Check the support of long parameters (strings)
PF9100123439 5 - Enhancement ETM: additional information in
list_etm_cnfg (PSTN line voltage and rotay switch)
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Command COP_DIAGNOSTIC does not work.
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.38.04
--------
Delivered (d/m/y):17/04/2008
PC/NT : S00x.exe, 7,602,223 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100122769 1 - Critical Correction trip to blind floor followed
by a Fatal Error
PF9100123361 2 - Major Bio1-nodes: 1st LOP Count: problem - following
LC OK
PF9100123288 2 - Major RPHT is enable in FIRE SERVICE
PF9100123380 2 - Major when SPRINKLER is active KSKB is disable
PF9100123274 3 - Average RESUBMITTED SPECI Views for Menu 10
PF9100123320 3 - Average RESUBMITTED KFM with menu 104: CAR travel to
TOP floor with opened door (with penthause)
PF9100122865 3 - Average Error LOG not canceled by pressing the "enter"
for more than 3s
PF9100121966 3 - Average Elevator doesn't go in to fatale error if the
CLC is out of range
PF9100101434 3 - Average DH: stop in car temporary disable the LOP
acknowledge
PF9100122560 3 - Average Elevator is in fatal error after SW upgrade
(eprom erase is needed)
PF9100123372 3 - Average rollback: CF02PA1 - remove automatic fire
recall floor assignment
PF9100083070 3 - Average wrong initialization of BMK RRE_A after startup
PF9100122672 3 - Average EARTHQUAKE wrong lamps in some cases
PF9100123323 3 - Average RESUBMITTED Programming SIMCARD via command
interpreter
PF9100123348 3 - Average Controller does not reset the CLSD when it is
blocked
PF9100122694 3 - Average AAT Test 88 (KNE Top Position)
PF9100121854 3 - Average Over temperature time increased to 10 minutes
PF9100123095 3 - Average Sprinkler recall NZ- output fire indicator
(LEF) doesn't lit
PF9100123285 3 - Average with STOP IN CAR restricted access (EBR1) is
disable
PF9100131103 3 - Average door reversing CC is eneble on BR4 MY in
firefighter
PF9100122710 4 - Minor Maintenance DKFM: Elevator is blocked if KSKB
is activated during DKFM
PF9100083057 4 - Minor asymmetric duplex - show_lop_state bmk
PF9100123321 4 - Minor Sim card validity check with terminal commands
second part
PF9100122674 4 - Minor LAB remains OFF in Reservation, Sprinkler
Recall, SAB, ShaftOvertemp,Earthquake,DKFM
Improvement
-------------
PF9100081107 3 - Average Show date and time in error history (menu 50)
PF9100123196 3 - Average Do not accept time/date outside the certficate
range
PF9100083061 3 - Average BR4HK, behavior after power OFF/ON -> door in
middle position
PF9100123343 3 - Average Remove PSTN voltage command
PF9100123314 3 - Average Some recoverable error are reported too many
times in RMCC
PF9100122927 3 - Average Unknown messages from FC: enters a log in the
error list
PF9100123015 3 - Average Failures on CAN connection not trigger fatal
error.
PF9100123322 4 - Minor Turbo command to log with terminal at baudrate
115200
PF9100123362 4 - Minor Support Turbo command also if terminal is on
RS232
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Command COP_DIAGNOSTIC does not work.
Notes:
------
Please clear EEPROM before doing any upgrate to this version.
V9.38.03
--------
Delivered (d/m/y):28/03/2008
PC/NT : S00x.exe, 7,581,743 bytes
N/A
- New functionality: -
----------------------
PF9100083035 3 - Average New BR3 Australia Type B
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100083002 2 - Major HYD: fatal error -> emergency parking to level
1 not performed
PF9100083034 2 - Major asymmetric group - wrong Gong, LW-U, LW-D, Ack
PF9100101799 2 - Major E-RE / inspection to CBD - PROMS YXTN-75939N
PF9100121715 2 - Major DYNAHYD - learning trip downwards removce XKBV
triggers a reset
PF9100122204 2 - Major SDIC RESET with BR1 STD active elevator BLOCKED
PF9100102298 3 - Average elevator blocked when KEB is actived and make
RESET
PF9100121462 3 - Average NS21: COP DT-O not working during evacuation
phase
PF9100121868 3 - Average CF02PA1 - remove automatic fire recall floor
assignment
PF9100122550 3 - Average it's possible to travel on a restricted floor
with menu 110 (car calls)
PF9100122958 3 - Average Automatic car position: if a floor call in
execution to LDU floor elevator do an assert
PF9100123094 3 - Average Sprinkler recall NZ- Synchro trip performed
PF9100123142 3 - Average RMCC - not every time 9001
PF9100123217 3 - Average deactivation phase of BR4 HK-C is no correct
PF9100123241 3 - Average RESUBMITTED KFM with menu 104: CAR travel to
TOP floor with opened door (with penthause)
PF9100123242 3 - Average Sim card validity check with terminal commands
PF9100123252 3 - Average dual brand: LOP count problem after the LOP
teaching.
PF9100123275 3 - Average elevator make syncro when EBR1 is active in
FULLLOAD
PF9100083027 4 - Minor possible to configure BMKs on LOPMAT floors
where no inputs exist
PF9100121549 4 - Minor AAT- car leaves LUET-zone and performs an
emergency stop
PF9100122141 4 - Minor reservation not reactivated after synchro
(after inspection activation/deactivation)
PF9100123207 4 - Minor Command CLSD voltage generate a WATCHDOG_RESET
PF9100123268 4 - Minor BX4.3 slow reaction time of trip layer after
drive standby
Improvement
-------------
PF9100123038 3 - Average introduce CF40 L00 PA31
PF9100123168 3 - Average After Technicial left site, we need to send the
current elevator operation state
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
This release is based on 9.36 (never released) merged with 9.37.
V9.38.02
--------
Delivered (d/m/y):17/03/2008
PC/NT : S00x.exe, 7,569,455 bytes
N/A
- New functionality: -
----------------------
PF9100123113 3 - Average Add support to SCOP5H and COP AP-EU
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100122515 2 - Major Automatic evacuation doesn't works
PF9100101694 3 - Average SPECI: not possible to change BIO configuration
(CF40)
PF9100121880 4 - Minor CF 40 and CF41 not showed on the COP if HMI is
present
PF9100122354 4 - Minor problems on the remote configuration via CADI
PF9100101965 4 - Minor RIB is always active
Improvement
-------------
PF9100081102 3 - Average SPECI Views for Menu 10
PF9100123233 3 - Average New ETM communication state on menu 308 3
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
This release is based on 9.36 (never released) merged with 9.37.
V9.38.01
--------
Delivered (d/m/y):07/03/2008
PC/NT : S00x.exe, 7,569,455 bytes
- New functionality: -
----------------------
PF9100082996 5 - Enhancement CmdInterpreter-Cmd "show_all_ee_bio"
PF9100123053 3 - Average Voice Announcer TW/KR Implementation
PF9100123175 3 - Average New Sim Card Option BR3 Australia Type B +
visualization of BR4 Malaysia
PF9100123176 3 - Average Sim card option for different voice
announcement types
PF9100123189 3 - Average Terminal commands for voice announcement Taiwan
and Korea
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100122125 1 - Critical BR3BE, firefighter service lost
PF9100081098 1 - Critical Eeprom conversion
PF9100122183 2 - Major NS21 - Evacuation floor NOT given by BRx active
PF9100081101 2 - Major additional EEPROM conversion fixes
PF9100098451 3 - Average B5: No automatic Reset when Blind Floor is
configured by SPECI
PF9100122074 3 - Average KFM with menu 104: CAR travel to TOP floor with
opened door (with penthause)
PF9100102297 3 - Average Error 1556 - Class Error incongruence
PF9100123058 3 - Average implement the F69 error handling
PF9100122998 3 - Average Menu 60: shows wrong values
PF9100083031 3 - Average TS drive in inspection mode: travelling into
the buffer possible
PF9100123087 3 - Average BR3 BE and SIEU: not working beacuse SW detect
as SIAP (JNFF actives)
PF9100121870 3 - Average RNO input (NS21), configured on the BBUS is
normaly open instead normaly closed
PF9100123200 3 - Average EEPROM conversion, GS is not working, BMK of
LOP not updated
PF9100122073 3 - Average after LOP count no CF40-visibility of SLCUX-IO
PF9100082576 3 - Average Terminal over SDLL - performance problem 9.3
PF9100122942 3 - Average elevator make syncro when EBR1 is active in
FULLLOAD
PF9100123052 3 - Average BR4 HK wrong fire fighter operation with power
off/on
PF9100123061 3 - Average BR3 India - wrong deactivation phase.
PF9100123201 3 - Average E_EEPROM_ERROR_LOG_FILE_ERROR logged after
every eeprom erase
PF9100123199 3 - Average Remove CR + LF at the end of the remote
terminal commands
PF9100123190 3 - Average CF21 PA34 - Volume Ring Tones always audible
PF9100123003 4 - Minor HMI menu 50: error type indication timer is too
slow (10s)
PF9100121577 4 - Minor Elevator and HMI blocked with Test trip [20
--] active and PHT interrupt
PF9100121879 4 - Minor SCIC3: SDIC41.QC is not showed on the CF13PA2
(HW version)
PF9100083017 5 - Enhancement LOP EEPROM conversion - BMK for Bio1-
Relayoutput
Improvement
-------------
PF9100101674 3 - Average SPECI - MENU 50 Extended Diagnostics wrong
visualization
PF9100123007 3 - Average Glass Shaft service
PF9100123009 3 - Average Define a new service for the B5.4 for the power
emergency evacuation
PF9100123126 3 - Average deadlock with CADI and timer manager
PF9100123115 3 - Average CADI GC isn't connected to system with SCIC 3
PF9100123122 3 - Average Extend terminal commands with missing ascii
chars
PF9100123081 3 - Average Dump message queues on assert
PF9100123085 3 - Average CADI command to reactivate terminal on RS232.
PF9100123102 3 - Average Re-introduce task assertions in sendMsg with
ECOS
PF9100123105 3 - Average Do not overhead the system with string
conversion in MsgExp if it is not needed
PF9100123193 3 - Average Timer manager improvements implemented also for
SCIC 3
PF9100123074 4 - Minor SRAM functions optimized for SCIC3
PF9100123077 4 - Minor Build for SCIC5: SRAM package for Motorola
PF9100123072 4 - Minor Build for SCIC3: SRAM package for NetArm
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
This release is based on 9.36 (never released) merged with 9.37.
V9.37.01
--------
Delivered (d/m/y):28/02/2008
PC/NT : S00x.exe, 7,503,919 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100123133 1 - Critical Eeprom conversion
PF9100123134 2 - Major non-automatic doors: elevator blocked in door
closing error
PF9100123138 2 - Major BX with manual doors: Blocked in correction
trip
PF9100083023 2 - Major BioBus-Check reduce delay
PF9100123166 3 - Average EEPROM conversion
PF9100123127 3 - Average KA/KS policy reset in case car moves controller
is missing a request, sanity check leads a reset
PF9100123151 3 - Average Many biobus frames for the PSI board
PF9100123132 3 - Average BR4 HK wrong fire fighter operation with power
off/on
PF9100123130 3 - Average CADI GC isn't connected to system with SCIC 3
Improvement
-------------
PF9100123129 3 - Average Timer manager: timer ID uniquely assigned to
avoid loss of timers
PF9100123191 3 - Average Timer manager improvements implemented also for
SCIC 3
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
This release is based on V9.35.
V9.36.01
--------
Delivered (d/m/y):31/01/2008
PC/NT : S00x.exe, 7,524,399 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100121576 2 - Major BIONIC5 Rel4 invalid command to CLSD after +++
switch to command mode
PF9100121447 2 - Major SDIC RESET:elevator is blocked with door close
in fire main floor
PF9100121788 2 - Major SPLINKER RECALL or "EARTHQUAKE" options
inserted on the SIM-CARD, LOOP W-DOG reset
PF9100123012 2 - Major BX with manual doors: Blocked in correction
trip
PF9100122987 2 - Major after overload NF1 is not active
PF9100122956 2 - Major BR2 France � after a reset in firefighter mode
the door close
PF9100083006 2 - Major non-automatic doors: elevator blocked in door
closing error
PF9100122997 3 - Average Special command 113 DT-S doesn't works, in
particular situation
PF9100102177 3 - Average during LEARNING TRIP if open and close safety
chain car is blocked
PF9100123051 3 - Average KA/KS policy reset in case car moves controller
is missing a request, sanity check leads a reset
PF9100082998 3 - Average remove unused BMK 300-304
PF9100121820 3 - Average BR2 SG-A - Firefighter OFF, no evacuation phase
PF9100121869 3 - Average BR3 India - KBF firefighter mode
PF9100101543 3 - Average BR3 Korea JNFF-S doesn't close the door at slow
speed
PF9100102290 3 - Average RESUBMITTED in FATAL ERROR car is BLOCKED on a
floor
PF9100083000 3 - Average Programming SIMCARD via command interpreter
PF9100102107 3 - Average CADI GC isn't connected to system with SCIC 3
PF9100122888 5 - Enhancement Door debug: compiler fix
PF9100083007 5 - Enhancement Bio2 cmd-naming in listmode
PF9100083009 5 - Enhancement BIOGIO: extend show_lop_state
Improvement
-------------
PF9100082910 3 - Average free configurable output for Bio1-Nodes
PF9100123023 3 - Average KFM activated via dip 7: not known if active:
add operation state on HMI
PF9100123045 3 - Average Add show assert in the system_info
PF9100102367 3 - Average different behavior between flor call and floor
call(BF) in full load
PF9100122949 3 - Average ETM: remove log if debug has not been activated
PF9100122963 3 - Average Timer manager: timer ID uniquely assigned to
avoid loss of timers
PF9100122989 3 - Average ETM: do not reset CLSD when it is not leaving
ALARM OFF HOOK state
PF9100122990 3 - Average Version 9.35.02 does not compile for Motorola
PF9100122992 3 - Average System info doesn't list the NF1 simcard option
PF9100102314 3 - Average CLSD ProSLIC recovery
PF9100120299 3 - Average ETM: the parameter set from RMCC must be
checked
PF9100122970 3 - Average Statistic information are reset proof
PF9100101711 3 - Average Give visual warning in case no applicatoin is
available on SCPU
PF9100122996 4 - Minor ETM: extend terminal command to list also the
number of CLSD reset
PF9100082990 5 - Enhancement refactoring of BioBus-Log
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
This release is canceled. See furthercome V9.38
V9.35.02
--------
Delivered (d/m/y):03/01/2008
PC/NT : S00x.exe, 7,503,919 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100121537 2 - Major BR2France and EBR1, the elevator is blocked,
reset is needed
PF9100102379 3 - Average RESUBMITTED assertion after "CF_DUMP" command
PF9100101296 3 - Average NF1 - LNFC works on SAIO even if its BMK is not
configured
PF9100122973 4 - Minor lamp RE_A is not switch on after a reset in
fire mode
Improvement
-------------
PF9100122974 4 - Minor Small optimization in carcontroller
PF9100122966 3 - Average Sanity Check Timeout State Machine improved
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
V9.35.01
--------
Delivered (d/m/y):14/12/2007
PC/NT : S00x.exe, 7,503,919 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100122930 2 - Major in Syncro RPHT not disabled in case of fire
PF9100122935 2 - Major RESUBMITTED - Overtemp never ending at startup
Improvement
-------------
PF9100122929 3 - Average duplex does not work with old sim card format
(7mio without equipment number)
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
V9.34.04
--------
Delivered (d/m/y):12/12/2007
PC/NT : S00x.exe, 7,503,919 bytes
N/A
- New functionality: -
----------------------
PF9100122909 3 - Average Equipment number: do not send ending space
PF9100102303 4 - Minor duplex: with new simcard comand 117 not work!
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100122916 2 - Major Overtemp never ending
PF9100082719 3 - Average Error LED should blink during montage service
PF9100122914 3 - Average Timer manager wrap around flags are not reset
PF9100122908 2 - Major The HMI in AAT test shows sometimes wrong
values
Improvement
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
V9.34.03
--------
Delivered (d/m/y):11/12/2007
PC/NT : S00x.exe, 7,503,919 bytes
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100101987 3 - Average BIOBUS with dual-brand: during a car call the
CPIF is updated on all floor.
PF9100102008 3 - Average wrong procedure to replace a broked motor
overtemp sensor
PF9100102399 3 - Average ETM: CLSD volume must be sent to CLSD
PF9100102398 3 - Average Timer manager wrap around causes a w-dog reset
Improvement
-------------
PF9100102374 2 - Major RESUBMITTED - BR2 and EBR1 - JNFF on, during a
car call active RSPE-K
PF9100102376 3 - Average ETM: ETM_GET_ERRORS
PF9100122899 3 - Average ETM: changes done to improve incoming calls
PF9100082975 5 - Enhancement BioBus collission test
PF9100122894 3 - Average Germany toll free number wrong
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
V9.34.02
--------
Delivered (d/m/y):05/12/2007
PC/NT : S00x.exe, 7,503,919 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100082892 3 - Average ISCPU (eCos) + SAIO => SAIO may not be detected
PF9100082916 3 - Average mixed shaftdoors: automatic door opens at the
end of the synchro trip
PF9100082964 3 - Average Yaskawa + SEM: no evacutation trip performed
PF9100082974 3 - Average SCPU: BioBus - serial data format - 1bit
missing vs. Bio-Nodes
PF9100101612 4 - Minor 0-Series feedback - the controller break
PF9100101817 3 - Average BR2 CN - on the COP the fire symbol is OFF
after a reset
PF9100101952 3 - Average BR3 BE - Door reopen after pressed once the DT-
O button on COP
PF9100102163 2 - Major BR2 and EBR1 - JNFF on, during a car call
active RSPE-K
PF9100102165 3 - Average RESUBMITTED - Display the CLC disabled state
PF9100102171 4 - Minor BR1 EN81-73 Type C, wrong ACID COP indication
PF9100102291 3 - Average LOP BF floor call buttons/acknowledges active
PF9100102295 2 - Major SCPU: Errors in Biobus frame handling
PF9100102301 3 - Average Elevator operation state is 90xx
PF9100102305 1 - Critical Component used outside its tolerances
PF9100102311 3 - Average Handicap Service: 96= unknown serviceIDforRamid
PF9100102313 3 - Average The default type of the CLC for BX is wrong
PF9100102315 1 - Critical Dynahyd blocked in synchro trip
PF9100102323 3 - Average BR3 STD - Wrong visualization on ACID display
in firefighter mode
PF9100102330 3 - Average JAB on HMI wrong signalization on display
PF9100121125 3 - Average assertion during ETM detection (menu 128)
PF9100121198 3 - Average COPH: (CPID) indication is not updated in
duplex asymetric.
PF9100121216 3 - Average DM236- Door - boarding time, -exit time, -
minimum open time are not right
PF9100121231 3 - Average duplex disabled after CADI activation
PF9100121234 2 - Major While BR service Door Hearth Beat error--
elevator is blocked
PF9100121235 3 - Average SDIC RESET:car doesn't open a door in fire main
floor
PF9100121239 3 - Average NS21: elevator perform synchro and then
evacuation even if OVERLOAD is active
PF9100081066 3 - Average Wrong FC parameter blocks startup (with no COP
connected)
PF9100101959 3 - Average New operation status are not trasmitted by ETM
PF9100102312 4 - Minor ACID display not refresh while the JAB is
activated.
Improvement
-------------
PF9100081085 3 - Average EEPROM conversion of COP file
PF9100081086 3 - Average Menu 105 and 116 delete functionality
improvement
PF9100081090 4 - Minor Configuration parameter parse tool update for
speci ids
PF9100081093 4 - Minor Terminal configuration CF_DUMP, CF_START
PF9100082967 4 - Minor Build for SCIC3
PF9100082975 5 - Enhancement BioBus collission test
PF9100100710 4 - Minor SMIC6: correct the values of CF13 according to
the new HW
PF9100100964 2 - Major TSD STOP mode active after a power failure
followed by an evacuation
PF9100102288 2 - Major CLSD voltage detection can not be changed once
detected
PF9100102293 3 - Average ETM: ETM_SET_CALL_INTERVAL
PF9100102349 3 - Average CLSD SW version for RMCC
PF9100102287 3 - Average Backward compatibility in sim card commands for
country code and equipment number
PF9100081066 3 - Average Wrong FC parameter blocks startup (with no COP
connected)
PF9100101959 3 - Average New operation status are not trasmitted by ETM
PF9100102242 3 - Average Timer manager improvement to better consider
wrap around
PF9100102316 3 - Average SW-INTERNAL Check and recode to avoid possible
buffer overflows
PF9100102312 4 - Minor ACID display not refresh while the JAB is
activated.
PF9100102364 2 - Major SCPU Boot V1.2
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
V9.34.01
--------
Delivered (d/m/y):16/11/2007
PC/NT : S00x.exe, 7,487,535 bytes
N/A
- New functionality: -
----------------------
PF9100101916 3 - Average Add a CF menu for choose on which COP you want
key input
PF9100102226 3 - Average Edit the Modem Init String on old HMI
PF9100102213 3 - Average Menu 116: Learning trip activation
PF9100102217 3 - Average CF13: add COP4 ZLA item
PF9100102183 3 - Average ETM: UNDO periodic modem reset
PF9100120300 3 - Average ETM: Start call after startup if breakdown in
buffer
PF9100101011 3 - Average Rework: ETM: Remove Message Leaks
PF9100102236 3 - Average implement again the setNextCallTestPeriod
method
PF9100102243 3 - Average Change sim card commands for country code and
equipment number
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100102193 2 - Major ETM blocked into " DISCONNECTING" status
PF9100102079 2 - Major Handicap Service + JAB, elevator serves the
landing call (BF)
PF9100102149 2 - Major RESUBMITTED-OVERLOAD no detect after deactive
FIRE SERVICE
PF9100082954 1 - Critical Dynahyd + ISCPU: KS/KS1 signal sequence
wrong -> fatal error
PF9100081081 3 - Average Winsim startup
PF9100102219 3 - Average in PI DUPLEX 2.nd elevator doesn't served CAR
CALL
PF9100102091 3 - Average Asymmetric Shaft Duplex - Elevator Reset
without Reason
PF9100102269 3 - Average Remove log of E_BIOBUS_NODE_DEAD
PF9100102117 3 - Average JDE visualization missed on "system_info" or
"show_lop_state"
PF9100102203 2 - Major Elevator Startup with car out of door zone
could block the elevator in service DoorHeartBeatError
PF9100102208 3 - Average to many "unknow code" sent to RMCC
PF9100082951 3 - Average JAB improvement all sources work
PF9100102159 3 - Average RESUBMITTED - OVERLOAD when jab is actived
elevetor close a door
PF9100102172 3 - Average ERROR during releveling: FATAL error car remain
on floor (not lowest)
PF9100102194 3 - Average in FATAL ERROR car is BLOCKED on a floor
PF9100102191 3 - Average No CLSD detected, worng alarm generated
PF9100102209 3 - Average Timer manager does not consider wrap around->
timer elapsed earlier!
PF9100102062 2 - Major elevator blocked if a call is gived during RL5
Improvement
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
V9.33.03
--------
Delivered (d/m/y):26/10/2007
PC/NT : S00x.exe, 7,450,671 bytes
N/A
- New functionality: -
----------------------
PF9100102166 4 - Minor SHOW_LCD_STATE command
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100102182 1 - Critical Menu 132 has to be invisible
PF9100102154 3 - Average RESUBMITTED New Menu for Commissioning has
another number
PF9100082952 3 - Average BIOBUS with dual-brand: during a car call the
CPIF is updated on all floor.
Improvement
-------------
PF9100102180 3 - Average ETM: periodical HW reset of the CLSD must be
implemented (30minutes)
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
V9.33.02
--------
Delivered (d/m/y):19/10/2007
PC/NT : S00x.exe, 7,450,671 bytes
N/A
- New functionality: -
----------------------
PF9100102047 1 - Critical Display the CLC disabled state
PF9100101962 3 - Average HMI: "," and "=" must be available for CF 21
PA15-19 (init string)
PF9100081074 3 - Average CF21 PA15 increase modem init string size to 64
chars (+EEPROM conversion)
PF9100102133 3 - Average ETM: 2nd part of improvements to increase
stability in SCIC-CLSD communication
PF9100102103 3 - Average ETM: improvements to increase stability in
SCIC-CLSD communication
PF9100102070 2 - Major Separate Montage from Learning Travel
PF9100081070 2 - Major CPLD improvment
PF9100081071 5 - Enhancement CF21 PA15 and PA16 long parameter view
PF9100100528 5 - Enhancement To avoid Maintanance on-off on
installation with TSD after reset
PF9100120236 3 - Average ETM: Add Call Type message
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100102018 3 - Average EXTID wrong defined for SPECI
PF9100102122 3 - Average CLC disabled has a new elevator operation state
PF9100102015 3 - Average Landing panel config not correct with COPH
PF9100101924 3 - Average RESUBMITTED- Sub-Menu 108 � Enable/Disable JAB
doesn't works
PF9100081066 3 - Average Wrong FC parameter blocks startup (with no COP
connected)
PF9100102054 3 - Average CF40 LE00 PA99 is not implemented
PF9100101966 3 - Average Elevator doesn't goes in to fatal error in
learning, after opening the KNET
PF9100101959 3 - Average New operation status are not trasmitted by ETM
PF9100101961 3 - Average ETM: Modem init string: avoid sending blanks to
modem
PF9100102129 2 - Major New Menu for Commissioning has another number
PF9100101925 3 - Average SMIC6,:XTELE doesn't wotks
PF9100102139 3 - Average BR1 EN81 type B and C : wrong behaviours and UC
not updated
PF9100102130 2 - Major New scale and default value for retries ETM
call
Improvement
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
V9.33.01
--------
Never released
V9.32.02N
---------
Delivered (d/m/y):07/11/2007
V9.32.02
--------
Delivered (d/m/y):22/10/2007
PC/NT : S00x.exe, 7,458,863 bytes
COLDFIRE (SCIC 6):
SCC6_932.BIN checksum: $07E14123
N/A
- New functionality: -
----------------------
PF9100082367 3 - Average SCIC6: New Restriction on usage of LUET signal
PF9100101773 5 - Enhancement SIM Card Formatting after end
configuration
PF9100101979 4 - Minor Drive parameter: Include in system_info the
value stored in SIMcard (86:=1)
PF9100102056 3 - Average If CLSD is for more then 1 hour in Alarm ==>
issue a CLSD reset
PF9100102069 3 - Average ETM: improvements to increase stability in
SCIC-CLSD communication
PF9100102072 4 - Minor Menu 129: detection improvements
PF9100102078 3 - Average ETM: avoid to start the init sequence if we
know that CLSD is OFF HOOK
PF9100082940 5 - Enhancement BioBus-Analyzer to BIONIC-Log translator
for WinSim
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100102130 2 - Major New scale and default value for retries ETM
call
PF9100081069 3 - Average Controller startup problem with WinSim
PF9100079674 3 - Average Wrong ACID behaviour with DE + non-automatic
doors + door reversing
PF9100082923 2 - Major synchro trip not correctly performed for SCTS
and TS drive
PF9100082932 2 - Major workaround for: SEM, automatic evacutation ->
door does not open after evac
PF9100082938 1 - Critical Hydraulic: elevator blocked in synchro
trip
PF9100101878 3 - Average JAB does not work with CANIO
PF9100101957 4 - Minor DM236: door open timer shall change to new
default values
PF9100102028 2 - Major While BR service Door Heart Beat error -
-Elevator is blocked
PF9100102034 3 - Average KBF on machine room nodes doesn't works
PF9100102041 3 - Average elevator doesn't serve olds pending calls
PF9100102063 3 - Average PSI board - gray code doesn't support 25 floors
PF9100102064 3 - Average Final Timer COP DTO door close with normal
speed
PF9100102068 3 - Average Equipment number option is not erased
PF9100101967 2 - Major overload when BR1 is actived,elevator locked
Improvement
-------------
Known limitations:
------------------
JAB does not work if installed on both SLCUx and CANIO board
Notes:
------
V9.32.01
--------
Delivered (d/m/y):03/10/2007
PC/NT : S00x.exe, 7,430,191 bytes
N/A
- New functionality: -
----------------------
PF9100100902 3 - Average SW-INTERNAL Check and recode to avoid possible
buffer overflows
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100100201 3 - Average Loss of backwards compatibility with BX Rel. 1
(SMIC3.Q)
PF9100082927 3 - Average Support of SMIC3 + SAIO (+SHMI)
PF9100101701 2 - Major BR3KR - BR3AU - After Activation of JBF reset
causes in loop
PF9100101587 3 - Average RV1 activation wrong floor number on ACID
PF9100101958 3 - Average Minimal Load functionality is not working in
non collective policy -Procits LOC1-070010
PF9100101552 3 - Average LUB is activated - LUB does not work on COPH
PF9100101444 2 - Major BX-HY- Before a call XCTR pin 6 is interrupted
- reset occurs
PF9100119741 2 - Major SEM, Automatic evacuation --> Elevator does not
stop at next floor
PF9100101759 3 - Average Resubmitted - New GET/SET parameters in SCAN
interface
PF9100082924 2 - Major Hydraulic: overtemperature threshold 2 does not
work in any case
PF9100101977 3 - Average Earthquale service is always registered
(SIMCARD not considered)
PF9100101317 3 - Average After configuration of KL-X elevator is blocked
PF9100082911 2 - Major mixed shaftdoors endurance test -> assertion
after a few trips
PF9100101659 3 - Average NS21: JNO timeout equal to zero, no release of
this car does not work
PF9100101560 3 - Average NS21, elevator start synchro without RFEF
signal
PF9100101328 3 - Average If DIP 6 is set ON while EB service is active
system resets in loop
PF9100101936 5 - Enhancement Microtek compiler alignment
Improvement
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
V9.31.07
--------
Delivered (d/m/y):21/09/2007
PC/NT : S00x.exe, 7,454,767 bytes
COLDFIRE (SCIC 6):
SCC6_931.BIN checksum: $07D7C3DE
N/A
- New functionality: -
----------------------
PF9100101901 2 - Major Only one COPH installed: no car calls possible
PF9100119338 3 - Average ETM: Add GSM detection and initialization
PF9100101890 3 - Average Battery low condition: error no more dispatched
PF9100101825 4 - Minor SHOW_SERVICE_STATE command
PF9100101897 4 - Minor CF08 PA1 wrong range: rollback
PF9100101859 4 - Minor CF08 PA1 wrong range
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100101909 3 - Average NO_OPERATION_DUE_TO_CAR_OVERLOAD state is not
Overload
PF9100101869 2 - Major assertion with EBR1
PF9100101849 2 - Major RESUBMITTED EEPROM conversion from 9.3.26 ->
9.31.05 ETM fault
PF9100101818 3 - Average Wrong "elevator status" for NF1
PF9100101790 3 - Average menu 129 (COP detection) works only one time
PF9100101870 3 - Average RESUBMITTED - Extend RV1 restriction for all
"restricted access"
PF9100101915 2 - Major Inhibit keys on 2nd COP
PF9100101905 2 - Major Test Trip execute in firefighter mode at start-
up
PF9100101865 3 - Average SMIC6 Wrong Inspection � normal led's behavior
PF9100101828 3 - Average BR3 STD - SDIC reset Door remains locked
PF9100101868 3 - Average SIMCard: country code value never use in free
configuration.
PF9100120136 3 - Average ETM: Clean Up Modem Type
PF9100101882 2 - Major RESUBMITTED - ALL BR - After a reset not
possible deactive the fire
PF9100100748 3 - Average BR3 AU: Car starts to serve car call even JNFF-
S is activated or not (with closed door)
PF9100101886 3 - Average Sub-Menu 108 � Enable/Disable JAB doesn't works
Improvement
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
EEProm conversion with ETM doesn't work
Notes:
------
V9.31.06
--------
Delivered (d/m/y):14/09/2007
PC/NT : S00x.exe, 7,458,863 bytes
N/A
- New functionality: -
----------------------
PF9100119974 3 - Average ETM: Minor bugfixes regarding auto config
PF9100101841 3 - Average Extend RV1 restriction for all "restricted
access"
PF9100081064 3 - Average Assert log in eeprom
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100101781 3 - Average RESUBMITTED - "CF_DUMP" command, controller
perform an assertion
PF9100081061 3 - Average Menu 129 COP detection; Reset EEPROM data
before detecting
PF9100101814 3 - Average RESUBMITTED - Restricted Access Functions (ZB)
Configuration (Security Mode Independent Service )
PF9100101816 3 - Average BUG on CF04 (time setting)
PF9100081062 3 - Average Car light timeout parameter blanked during
conversion 8.6->9.31.04
PF9100101829 2 - Major photocell doesn't works with EBR1 (in normal
mode)
PF9100101824 1 - Critical RESUBMITTED EBR1-After car overides
called floor acknowledge lamps remains ON
PF9100082912 3 - Average Door opens between floors after power up
PF9100101845 3 - Average Automatic prefix phone test doesn't works
PF9100101832 3 - Average ETM free configuration: phone number is changed
during detection
PF9100101501 3 - Average B1M missing BMK value of JBF
PF9100119951 1 - Critical Assert if JAB on macine room node
PF9100101687 3 - Average RESUBMITTED BR1 service is active - After a
reset a syncro trip is performed
PF9100101532 3 - Average BR2 China JNFF deactivation fire fighter mode
Improvement
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
EEProm conversion with ETM doesn't work
Notes:
------
V9.31.05
--------
Delivered (d/m/y):07/09/2007
PC/NT : S00x.exe, 7,454,767 bytes
COLDFIRE (SCIC 6):
SCC6_931.BIN checksum: $07D49AF0
N/A
- New functionality: -
----------------------
PF9100081057 3 - Average SMIC6 display support
PF9100101760 3 - Average New SIM card option for the equipment number
PF9100101761 3 - Average ETM fre configuration only with SIM card with
EquNr
PF9100101538 3 - Average ETM Modem Country Init String should be
available on HMI for SMIC6
PF9100101805 3 - Average elevator operation state for UI - part 2
PF9100100901 3 - Average SW-INTERNAL Check and recode to avoid possible
buffer overflows
PF9100101762 3 - Average Duplex Master/Slave with EquNr
PF9100101662 3 - Average EEPROM conversion from 9.3.26 -> 9.31.03
(EmbeddedRMCnfgNormalMgr)
PF9100101194 4 - Minor SMIC6: LCD backlight shall switch off after a
few minutes of timeout HMI
PF9100101797 4 - Minor SHOW_SERVICE_STATE command
Integration tests:
------------------
Bugfix Corrected:
-------------
Improvement
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
V9.31.04
--------
Delivered (d/m/y):03/09/2007
PC/NT : S00x.exe, 7,401,519 bytes
N/A
- New functionality: -
----------------------
PF9100081056 3 - Average LOP detection menu 130
PF9100081058 3 - Average Improve Extended Diagnostic for COP device
PF9100082906 3 - Average SW internal: handle certain hardwired IOs as
BMKs
PF9100081054 3 - Average Cleanup SpecialFunctions BL
PF9100081053 3 - Average COP detection menu 129
PF9100101685 2 - Major Services : m_elevatorCallExecutable handling
PF9100101717 3 - Average elevator operation state for UI
PF9100101667 3 - Average Add CommandCmd For trafficMgr
PF9100101671 3 - Average Restricted Access Functions (ZB) Configuration
(Security Mode Independent Service )
PF9100101665 3 - Average call executability parametrization for Special
policy
PF9100101707 3 - Average replace message available and unavalabel with
new one: operation state
PF9100101670 3 - Average ETM free configuration: automatic configuration
call
PF9100101715 4 - Minor FC SW: version shall be listed in EC system
info
PF9100101351 4 - Minor GAC Floor DT-O to UP trigger a double gong
sound
PF9100101736 4 - Minor At startup level with null value are not
considered anymore
PF9100082790 5 - Enhancement Support for signal RRE-A and CLC up to
2550 kg
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100101678 3 - Average CF_DUMP command, controller perform an
assertion
PF9100101559 3 - Average REFE1 on plug "OPTIONS" on SMIC5 doesn't works
PF9100101388 3 - Average DH: stop in car button connected to a COPH
operates as a N.O. contact
PF9100101391 3 - Average Landing Gong doesn't sounds in PI when serving
a floor call at current floor
PF9100101700 2 - Major BR4 HK: firefighter operation can be
deactivated in all floor and all door state.
PF9100049680 2 - Major FAN remains on when COP5 is reconfigured
PF9100101698 3 - Average RESUBMITTED RIB remains ON in Recall Control
Service
PF9100101679 3 - Average PINCODE with 3 digit is not working
PF9100082652 3 - Average UI: In case of SAB, "--" not shown on gray code
indicators on COPH, 2nd COPH and LCU
PF9100033009 3 - Average Car light and car fan are activated after after
completed evacuation phase
PF9100101719 3 - Average COP4, the LOP teached with fire key sound two
times
PF9100101672 3 - Average RESUBMITTED NO TSD platfrom, wrong LED on SMIC
(normal,inspection)
PF9100101406 2 - Major Stop in Car - BMK on SAIO works as N.O. contact
PF9100101562 3 - Average TM4/ETM sends only full load, overload or
unknown to RMCC
PF9100101199 3 - Average synchro ends by timeout when all LOPs virgin
PF9100078796 3 - Average JLC Sub-Type "B" is OFF after floor call ACL
gets activated
PF9100082782 3 - Average schoolhouse - JDE_E only event triggered
PF9100101573 3 - Average JAB-switch=on, but service JAB inactive after a
SCIC reset
PF9100101564 3 - Average Input key on SLUX are wrongly moved to other
input
PF9100101709 3 - Average wrong CC number on sim card
PF9100101686 3 - Average After reset, recall button up pressed, car was
moving down
PF9100101616 4 - Minor DESF - KSE LED is not disabled
PF9100101446 4 - Minor Inspection mode stop if up or down buttons are
pressed on ESE
PF9100101763 3 - Average LOP Scan: slave nodes are not scanned
Improvement
-------------
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
V9.31.03
--------
Delivered (d/m/y):16/08/2007
PC/NT : S00x.exe, 7,360,559 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100101605 2 - Major While BR1service SDIC reset - door closes and
remains closed
PF9100101435 2 - Major Telemonitoring: Too many "Bad controller
communication" messages arriving in RMCC
PF9100101405 2 - Major Partition door combined with JRVC - DT-O does
not work properly
PF9100101620 2 - Major machine room node visibility
PF9100101155 3 - Average Resubmitted - SGEC test never successful
PF9100082889 2 - Major bug fixes in Input and Output table
PF9100101443 3 - Average NO TSD platfrom, wrong LED on SMIC
(normal,inspection)
PF9100082900 3 - Average B1M CF40 visibility
PF9100082890 3 - Average Telemonitoring - SDLL connect counter range
PF9100101628 3 - Average B1M after the LOP COUNT the JDE key doesn't
works
PF9100101631 3 - Average CF40 - PA21 not visible with BIO2M
PF9100101086 3 - Average SLOPD52.Q A - LAB doesn't light with a
connected LIN
PF9100101295 3 - Average elevetor made a synchro after a timeout of
drive standby with floor call pending
PF9100101618 3 - Average Elevator seldom perfoms correction trip
PF9100101621 3 - Average Processing power wasted setting repeatedly the
same output
PF9100101469 4 - Minor LOP EU CF 40 PA22 available
PF9100101602 4 - Minor Wrong visualization with command show_lop_state
Improvement
-------------
PF9100082888 3 - Average cleanup OutputTable (software internal)
PF9100082884 3 - Average inputs: unique debug printouts for all
platforms (software internal)
PF9100101458 3 - Average LOP teaching with COP4 or COPH
PF9100082885 3 - Average cleanup InputTable (software internal)
PF9100081047 3 - Average New ETM parameter CF21 PA35 CC_Number_Prefix
PF9100101644 3 - Average Add new PA 0 to CF 41
PF9100082894 3 - Average SW-Internal: SDLL refactoring
PF9100082895 3 - Average SW-Internal: SDLL protocoltest
PF9100082887 3 - Average SW-INTERNAL: SDLL TimerId set invalid after use
PF9100081045 3 - Average Changes for WinSimulation platform phase II
PF9100100895 3 - Average Check and recode to avoid possible buffer
overflows
PF9100101585 3 - Average ETM: ON HOOK Voltage teaching procedure and
command
PF9100101649 3 - Average ETM: RMCC Phone number must be country
dependent
PF9100101651 3 - Average ETM: RMCC Phone number must be splitted
PF9100081050 3 - Average New menu 128 ETMPeripherieDetection
PF9100082898 5 - Enhancement SW-Internal: typo
PF9100082880 2 - Major BR4HK (all fire fighter services) behavior
after power OFF/ON
PF9100101531 5 - Enhancement Improvement date and time on Diagnostic
Menu
Known limitations:
------------------
On older SMIC2 the SW doesn't work correctly.
Notes:
------
V9.31.02
--------
Delivered (d/m/y):20/07/2007
PC/NT : S00x.exe, 7,245,871 bytes
N/A
- New functionality: -
----------------------
PF9100082416 3 - Average Introduce new message COPH_TEXT_DISPLAY for
COPHx
PF9100101413 3 - Average RIB remains ON in Recall Control Service
PF9100082747 3 - Average HMI: Enable ALL alphanumeric characters if MOD
controller
PF9100100896 3 - Average SW-INTERNAL Check and recode to avoid possible
buffer overflows
PF9100101506 3 - Average ETM: Modem improvements
PF9100033167 5 - Enhancement SW-ARCHITECTURE improve dependency
between biz logic and com package
PF9100081044 5 - Enhancement Changes for WinSimulation platform
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100101571 2 - Major P_MGBVA does not work
PF9100100640 2 - Major Door remains OPENED and calls are not served
PF9100101510 2 - Major End of door heart beat error -Elevator is
blocked
PF9100101509 2 - Major While BR service Door Heart Beat error -
-Elevator is blocked
PF9100101513 3 - Average HMI shows wrong HW and SW version of COPH
PF9100101427 3 - Average With Combo call, LOP LED and LOP arrows doesn't
lit when the car is travelling
PF9100101503 3 - Average Wrong CF40 visibility
PF9100101505 3 - Average BR service is active - After start UP syncro
trip is performed
PF9100100755 3 - Average AAT - Inconsistence between FBU and FBD
PF9100100754 3 - Average AAT - FBU assertion when triiggering stop
PF9100100743 3 - Average AAT - SGC - ACOP nominal speed not reached not
reported
PF9100100744 3 - Average AAT- assertion while ACOP test
PF9100100741 3 - Average during simulation FC_DRIVE_TRIP_TOO_LONG
PF9100100714 4 - Minor LINs don't show car position after leaving the
ext. diagnostic
PF9100109673 4 - Minor Reset and/or Fatal error by List Mode on
PF9100100716 2 - Major Parking 4 and 5: No calls served after call is
given behind car while travelling to parking floor
Improvement
-------------
Known limitations:
------------------
Notes:
------
V9.31.01
--------
Delivered (d/m/y):05/07/2007
PC/NT : S00x.exe, 7,319,599 bytes
N/A
- New functionality: -
----------------------
PF9100082838 3 - Average CF40 visibility according to LOP config
register
PF9100100891 3 - Average New GET/SET parameters in SCAN interface
PF9100082803 3 - Average misuse of error-numbers as service triggers
PF9100082754 3 - Average brake monitoring SCTS new functions and
improvements
PF9100082875 3 - Average IOHandler: LOP acknowledges for Win Sim
PF9100082681 2 - Major SCTS: correct introduction of parameters and
config file
PF9100098813 5 - Enhancement COP5 AP teaching for 25 floors
PF9100100900 3 - Average SW-INTERNAL Check and recode to avoid possible
buffer overflows
PF9100100706 5 - Enhancement COP4 ZLA support
PF9100082680 1 - Critical eeprom conversion for Two Speed drive
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100101416 2 - Major BR3: JNFF-S activate during travel, in
firefighter mode, elevator made an emergency stop.
PF9100082860 2 - Major Full Load + Overload: System doesn't resume
operation
PF9100082854 2 - Major Bugs in BR4HK
PF9100082684 2 - Major brake monitoring refactoring including bug
fixing
PF9100082686 2 - Major SCTS drive type CE125 not handled according to
specs
PF9100082812 3 - Average SCTS: wrong error E_DRIVE_BRAKE_OPERATION_FATAL
PF9100082682 2 - Major SCTS: parameterization via CF19 does not work
PF9100101381 3 - Average Remove logwrites
PF9100082679 2 - Major TS Drive: deceleration phase notification too
late
PF9100101344 3 - Average RESUBMITTED: Add a new CF - PA for SMIC HW and
SW (CPLD)
PF9100082685 2 - Major SCTS: feedback ISWAHA handled in case SWAHA
contactor not present => fatal error
PF9100082839 3 - Average show_lop_state - bio adr initialization
PF9100101467 3 - Average JDE on floor (floor call key), the acknowledge
on the LOP doesn't works
PF9100082848 3 - Average wrong timerId set to unusable
PF9100082687 2 - Major SCTS MCCE5 dip switches not used according to
specs
PF9100101354 4 - Minor BR1 CN - After evaquation is finished GAC gets
activated
PF9100101357 3 - Average CF01: automatic completion for AP levels
PF9100082609 2 - Major CF54 not visible
PF9100100364 3 - Average resubmitted re-leveling is ruinning, AAT become
active, elevator do strange emergency stop
PF9100100905 3 - Average SPECI connected at startup makes a controller
reset
Improvement
-------------
Known limitations:
------------------
Notes:
------
V9.3.26
-------
Delivered (d/m/y):27/06/2007
PC/NT : S00x.exe, 7,290,927 bytes
COLDFIRE (SCIC 6):
SCC6_930.BIN checksum: $07AEDE9D
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100101426 3 - Average REFEH1 on SMIC5 doesn't work
PF9100101439 3 - Average TSD not working on SCIC6
Improvement
-------------
PF9100101432 3 - Average Winsim compilation issue
Known limitations:
------------------
Notes:
------
V9.3.25
-------
Delivered (d/m/y):25/06/2007
PC/NT : S00x.exe, NOT RELEASED
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100101421 3 - Average Drive direction on SMIC5 doesn't work
Improvement
-------------
PF9100091189 3 - Average ETM add SSL recovery after protocol error
PF9100101414 3 - Average ETM: "Init Failed" string instead of "INIT FAILED"
PF9100101418 3 - Average ETM: Service visit timeout range
PF9100101389 3 - Average ETM: ATH command sent during initialization sequence
Known limitations:
------------------
Notes:
------
V9.3.24
-------
Delivered (d/m/y):25/06/2007
PC/NT : S00x.exe, 7,290,927 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100101371 3 - Average ETM remove unnecessary logs in modem and call
handler
PF9100101400 2 - Major Enter wrong password, the elevator becomes not
available
Improvement
-------------
PF9100101387 3 - Average ETM: increment delay before +++ to 1.5s
PF9100101386 3 - Average ETM: command for sending and collecting
statistic data at every outgoing call
Known limitations:
------------------
Notes:
------
V9.3.23
-------
Delivered (d/m/y):19/06/2007
PC/NT : S00x.exe, 7,290,927 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100091183 3 - Average ETM Reset SSL error counter after successful
accept
PF9100101349 2 - Major BR1 CH: Deactivation not possible after Power
off while active fire
PF9100082844 1 - Critical elapsed timer
PF9100101238 3 - Average UI: the "service number" doesn't change in
reservation active
PF9100101307 2 - Major Mixed up BMK table of SLCUX
PF9100101348 3 - Average SW-INTERNAL- Avoid to delete invalid timers
(II)
PF9100101336 3 - Average ETM: handle INIT FAILED message from CLSD
Improvement
-------------
PF9100101364 3 - Average ETM: +++ must be sent at the begin of the init
sequence
PF9100091180 3 - Average ETM add delay between voltage request and dial
command
PF9100101346 3 - Average SW-INTERNAL: filter correct timer msg
Known limitations:
------------------
Notes:
------
Changed bin filename to SCC6_930
V9.3.22
-------
Delivered (d/m/y):15/06/2007
PC/NT : S00x.exe, 7,286,831 bytes
- New functionality: -
----------------------
PF9100082826 3 - Average Address of BioBus nodes in show_lop_state
PF9100082821 3 - Average system_info - change 1 line
PF9100100898 3 - Average SW-INTERNAL Check and recode to avoid possible
buffer overflows
PF9100091169 2 - Major ETM avoid calling endlessly if buffer full and
RMCC down
PF9100101320 2 - Major Inform landingPanel Package About Group
comuniacation state (loose/gain)
PF9100081038 4 - Minor Remove FC alarm A59
PF9100082783 4 - Minor Minimal Load for Service NF1 also with CLC
PF9100082834 3 - Average HYD: Improvement of run time limiter
PF9100082833 3 - Average Enable Reservation with HYD
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100101247 1 - Critical ETM: Periodic timer not running after
OFF_HOOK in DATA_CONNECTED state
PF9100101278 1 - Critical Wrong handling of timers handing in
deadlock
PF9100101228 1 - Critical Safety chain overcurrent error in not
handled-> elevator blocked with no breakkdown
PF9100101266 2 - Major RV1 and RV2: Activation while door is open -
the door closes and opens once
PF9100101264 2 - Major RV1: Pending calls not cancelled at activation
of independent control
PF9100101069 3 - Average SMIC6: GBPD menu 103 remains 1 after
deactivation
PF9100081041 2 - Major Safety chain overcurrent error correction
PF9100101253 3 - Average RESUBMITTED: Add a new CF - PA for SMIC HW and
SW (CPLD)
PF9100101245 3 - Average Landing Call at top floor by HMI is not
possible
PF9100101313 2 - Major ETM: timer expiration cleanup
PF9100101312 2 - Major ETM: runbody protected before startup
PF9100101310 2 - Major SSL fixup
PF9100101216 3 - Average Error code cannot be represenntted
PF9100082832 3 - Average Correct service ID for Ramid
PF9100101227 2 - Major Safety chain overcurrent is not siganlized
PF9100101250 3 - Average ETM: with RMCC turn on SAB after some sec. SAB
disappears
PF9100101252 3 - Average ETM: JRV is not sent via Servitel interface
PF9100101285 3 - Average RESUBMITTED sometimes after learning trip the
ETM is not detected
PF9100101236 3 - Average ETM error, the 00 is not NO_ERROR
PF9100081031 3 - Average blocked can produces watchdog reset
Improvement
-------------
Known limitations:
------------------
Notes:
------
Changed bin filename to SCC6_930
V9.3.21
-------
Delivered (d/m/y):31/05/2007
PC/NT : S00x.exe, 7,278,639 bytes
N/A
- New functionality: -
----------------------
PF9100101187 3 - Average ETM: command to enable Logs during the
detection/initialization
PF9100100726 3 - Average Add a new CF - PA for SMIC HW and SW (CPLD)
PF9100081021 3 - Average Set menu visibility according shaft information
PF9100082820 4 - Minor Build for SCIC3
PF9100101213 3 - Average ETM: external modem configuration
PF9100101209 3 - Average ETM: configuration CF 21 parameter ranges
PF9100081032 4 - Minor char array in COP teaching HMI's not correct
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100101026 3 - Average CF86 on Simplex
PF9100101148 3 - Average Car Key Restricted access activation on SCOPH
triggers reset
PF9100101178 2 - Major spurious fatal error triggered while automatic
car position
PF9100101042 3 - Average SW INTERNAL: inconsisten handling of failure in
CL position trip
PF9100082817 3 - Average BIO1 slave standalone with wrong prot
PF9100101145 3 - Average Earthquake indicator is NOT active after a
Reset
PF9100101031 2 - Major Floor call by HMI in PI and DE policy is not
possible
PF9100100431 3 - Average Emergency Service NF1 - Marine application
PF9100100425 3 - Average NS21 Marine (sim card code 35)
PF9100101169 2 - Major GS acknowledge lamp up remains on if normal
floor call is served on GS floor
PF9100101122 3 - Average clearing error log via HMI (menu 50)
PF9100081035 1 - Critical Missing error handling for
E_SHAFT_ROUGH_POS_MISSMATCH_TOP
PF9100101136 3 - Average RESUBMITTED UI for LCD display on SMIC6 - step
3
PF9100101168 2 - Major RMCC call controller, the alarm on COP is
activated
PF9100101170 3 - Average sometimes after learning trip the ETM is not
detected
PF9100101230 4 - Minor SAS: destination indicator wrong update
PF9100101127 2 - Major TAM2 continues calling even after Ticket is
acknowledged
Improvement
-------------
Known limitations:
------------------
Notes:
------
Changed bin filename to SCC6_930
V9.3.20
-------
Delivered (d/m/y):24/05/2007
PC/NT : S00x.exe, 7,274,543 bytes
N/A
- New functionality: -
----------------------
PF9100100843 3 - Average ETM: Error handler compatible with SW component
PF9100100856 3 - Average Trip counter set with terminal command
PF9100081023 5 - Enhancement Eeprom conversion for v9.3x second
edition
PF9100101172 3 - Average ETM: CLSD HW & FW Versions
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100101138 1 - Critical SW-INTERNAL:Check and possibly correct
MMC SPI settings in bootloader
PF9100101184 3 - Average Timeout of 60 sec added in TM4
PF9100098525 3 - Average COP4 button acknowledge doesn't become blank in
CF
PF9100101177 2 - Major RESUBMITTED: Learning trip after JH off/on each
10times
PF9100101131 2 - Major CLSD to RMCC Connection Timeout
PF9100101132 2 - Major ETM_CLSD No Normal Traffic arrives when ETM
doesn't send a successfull Test Trip
PF9100101109 3 - Average After a reset elevator remains on
synchronization waiting for deactivation
PF9100100957 3 - Average at LOP teaching remove already configured JDE
PF9100091152 2 - Major ETM: CLSD HW reset during Alarm OFF-HOOK
PF9100101036 2 - Major E_SHAFT_INCOSTANT_LEVEL_INDICATORS sent wrong
PF9100100216 3 - Average HW id of SCOPMH3L is not seen, although the
COPH is operational
PF9100091151 3 - Average ETM: Phone Line busy Error ist not generated
PF9100101113 3 - Average ETM: call handler remains blocked in
disconnecting state
PF9100101128 3 - Average ETM_CLSD Wrong default baudrate for CLSD UART
is set
PF9100100718 3 - Average SAB deactivation, with CPIF options, all the
LIN show the car position
PF9100100821 3 - Average Reset occurs after each "system_info" command
Improvement
-------------
Known limitations:
------------------
Notes:
------
Changed bin filename to SCC6_930
V9.3.19
-------
Delivered (d/m/y):14/05/2007
PC/NT : S00x.exe, 7,270,447 bytes
N/A
- New functionality: -
----------------------
PF9100091139 3 - Average ETM send controller version as string
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100081020 5 - Enhancement Use already available traffic controls
states
PF9100081024 4 - Minor assert printout not printed with eCos
PF9100081028 3 - Average CPID does not display "Er" but it becomes blank
PF9100082770 1 - Critical lop scan with known addresses
PF9100082780 3 - Average initialization of service triggers from BioBus
BMK inputs not working
PF9100082787 4 - Minor Build for SCIC3
PF9100082802 3 - Average BMK to LOP button assignment for DE, PI
PF9100082804 5 - Enhancement ErrHndl - cosmetic
PF9100099156 3 - Average SMIC6: HMI shall be improved
PF9100100683 3 - Average Resubmitted - Re-leveling UP/DW enabled when
KNE-U active
PF9100100955 3 - Average People temporarily trapped and elevator blocked
due to KNE_U
PF9100101024 3 - Average SW INTERNAL: Allow saving of the ETM buffers in
static ram (application reset proof)
PF9100101057 2 - Major RESUBMITTED GS - LOP buttons config changes at
non-initial-learning Trip
PF9100101065 2 - Major Bootloader does not read real HW id for
selecting image to be read
PF9100101075 3 - Average UTC is not used in RMCC
PF9100101077 2 - Major The ETM is not reset proof
PF9100101092 3 - Average Country code from HMI is not working
Improvement
-------------
Known limitations:
------------------
Notes:
------
This release compiles under Motorola and NetArm too.
V9.3.18
-------
Delivered (d/m/y):04/05/2007
PC/NT : S00x.exe, 7,262,255 bytes
N/A
- New functionality: -
----------------------
PF9100101007 3 - Average UI for LCD display on SMIC6 - step 3
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100101030 2 - Major Floor call to lowest floor does not work in PI
policy
PF9100101034 1 - Critical Rollback: SW-INTERNAL protect the
observer pattern
Improvement
-------------
Known limitations:
------------------
Notes:
------
This SW is released due to AAT resets (101034)
V9.3.17
-------
Delivered (d/m/y):02/05/2007
PC/NT : S00x.exe, 7,262,255 bytes
N/A
- New functionality: -
----------------------
PF9100082580 3 - Average Embedded TM module errors - KID entry
PF9100082581 3 - Average Embedded TM - modem alive check
PF9100082741 2 - Major ZB_ZLA also for KA and KS policy + timer CF
change
PF9100082756 3 - Average send SCIC SW-Version to SPECI via string
PF9100082766 4 - Minor after SIM-card erase set default KA policy
PF9100091119 3 - Average ETM: Communication to RMCC improvements
PF9100091136 3 - Average ETM: Update HMI/SPECI status U1, U4, U5 and U9
PF9100100841 3 - Average RV2 problems
PF9100100926 3 - Average Handle battery low signal
PF9100100977 3 - Average ETM Serial Ticket Number should be persistent
PF9100099049 6 - not applicable EEPROM conversion 9.2 --> 9.3
PF9100100937 1 - Critical Add a method in ETM to Dispatch msg to
error Handler
PF9100100956 3 - Average UI for LCD display on SMIC6 - step 2
PF9100109909 3 - Average KNE Trip with simualiton 30:=419 on and DRH-U
inactiv
PF9100091128 3 - Average ETM: Remove Message Leaks
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100033144 3 - Average Wrong Car postion on LOP, while Syncro Trip
PF9100078794 3 - Average JLC switch ON -ACL remains activated
PF9100081017 2 - Major Blocked synchro due to LOP count => is an
integration error
PF9100081018 2 - Major After configuration by cop device left, press
Enter => view null pointer reset
PF9100082727 3 - Average HMI crash
PF9100082730 2 - Major MCCE4: During drive error, the door cannot be
opened by DTO
PF9100082731 3 - Average Door type 85 & 86: Add feature
DOOR_MUST_PUSH_LOCK
PF9100082757 3 - Average Visitor Operation - wrong BMK assignment below
main floor
PF9100082767 2 - Major UI - car position indication on all floors even
without CPIAF
PF9100082771 3 - Average eCos: ECU SAIO inputs do not work correctly
PF9100082778 1 - Critical Remove message leaks in SCTS brake
monitoring
PF9100099690 3 - Average SW-INTERNAL protect the observer pattern
PF9100100150 3 - Average elevator is in normal mode, every 10 min car
light and fan are switche ON
PF9100100371 3 - Average SMIC6: Elevator blocked in "Configuration
deactivating"
PF9100100436 3 - Average Lamp Car Direction up/down - Marine application
PF9100100606 3 - Average BR3 India: car call on current floor doesn't
close the door
PF9100100623 3 - Average RESUBMITTED Cop5B_10 KS-Display doesn't update
correctly when car calls are pending and Configuration is activated via HMI.
PF9100100631 3 - Average Send File with Tera Term - Config parameters
shown in tera term
PF9100100633 3 - Average RESUBMITTED Watchdog Reset by pressing Enter on
HMI during a trip
PF9100100717 3 - Average Parking 5: Disbabling with timer CF02PA05 not
possible
PF9100100763 2 - Major SMIC6: GBPD reset - move in inspection possible
if menu 103 is 0
PF9100100813 3 - Average Sometimes learning trip is performed 2 times
PF9100100832 2 - Major CADI - with ISCPU1- COM Port is not found
PF9100100836 3 - Average CF40 L XX PA99 cause configuration blocked
PF9100100845 3 - Average RESUBMITTED Pre-torque test (menu 123)
bottom/top doesn't work
PF9100100872 3 - Average P-Care reset
PF9100100873 3 - Average P-Care XTELE communication
PF9100100876 3 - Average RESUBMITTED AAT KNE test does not allow
measuring the car displacement
PF9100100883 2 - Major BF landing call button�s LED didn�t light after
the landing car registered
PF9100100888 3 - Average SW-INTERNAL replace sprintf with snprintf
PF9100100889 3 - Average SCPU the max number of floor is 25
PF9100100894 3 - Average Negative PIN code are not working
PF9100100904 3 - Average Wrong Show Lop State
PF9100100906 2 - Major GS - LOP buttons config changes at non-initial-
learning Trip
PF9100100907 3 - Average ETM: bring chat.c in ecos as it was originally
PF9100100918 3 - Average ACID indicator not working well during PIN code
PF9100100919 3 - Average RESUBMITTED ETM Phone number is only digit and
"-"
PF9100100927 1 - Critical CF86 on Simplex
PF9100100928 4 - Minor BR1 EN-B: RBF doesn't get active
PF9100100941 3 - Average CF03 PA10 and PA11 visible
PF9100100942 3 - Average On CF03 PA12-PA19 available
PF9100100944 4 - Minor On CF08 PA10 available also with KA Policy
PF9100100950 3 - Average spam LOG on CADI-terminal
PF9100100971 2 - Major LOP button and ack BMK-map has unvisible on
CF40
PF9100100984 3 - Average LOP calls during the door opening and closing
are executed separately. [Controller bug?]
PF9100100987 3 - Average SW-INTERNAL: printout the flash info in a
consistent way.
Improvement
-------------
Known limitations:
------------------
Notes:
------
New bootloader must be installed for checksum (PF9100100868)
SCIC Software Pair:
---------------------------------------
This version is tested to work with the following releases:
-------------------------------------------
FC(CXS) | Deli 61 or Deli 68
FC(NXP) | 3.34
SEM | V2.0.05
BBCtrl | V4.1.02 (4.1 - KA)
CPLD (ISCPU) | V1.07
CPLD (SMIC6) | V1.07
COP1 | KA
COP2 | KA
COP3 | V2.1
COP3A | V3.0.15 (KA)
COP4 | V2.2.00
COP4ZLA | X
COP5 | V1.8.03
COP5AP | V1.2.03
COP5NA | V1.0.02
COPH | V2.1
COPH3 | V3.3.02
COPMAT | V3.3.02
CANIO | V1.1.01
SDIC2 | X
SDIC3 | X
SDIC3A | V2.5.04
SDIC4 | V2.5.04
SDIC41A | V3.1.05
SDIC5 | V2.5.00
SDIC53 | V2.5.00
SLCU-M | V1.2.02
SLCU2-M2| V1.2.02
SLCUx | V1.2.02
PSI | V1.2.02
SLCU-MX | V1.2.02
SLOPM2 | V2.4.02
SLOPE52 | V1.4.02
SLOPEB52| V1.4.02
SLINV5 | V1.4.02
SLOP5 | V1.4.02
SPECI | V1.20 13.02.2007
CADI | V2.8 special for BIONIC
Simcard | Filesystem V5
-------------------------------------------
x = NOT compatible
KA = look latest KA software available for that device
V9.3.16
-------
Delivered (d/m/y):10/04/2007
PC/NT : S00x.exe, 7,172,143 bytes
N/A
- New functionality: -
----------------------
PF9100100766 3 - Average ETM Phone number is only digit and "-"
PF9100082739 3 - Average solve BIO-Bus JDE automatism problem
PF9100082740 3 - Average add RES_EMBEDDED_RM = 50
PF9100082751 3 - Average Visitor operation - reconfiguration of LOP
button meaning via CF17
PF9100081014 3 - Average CF21 modifications
PF9100100222 3 - Average SW-INTERNAL: Remove the variable
m_bIsMoveSubmitted from service correction
PF9100100811 3 - Average ETM: communication state
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100100825 2 - Major Synchro trip doesn't start (only if I press LOP
or COP button)
PF9100100812 1 - Critical System frozen for no apparent reason
PF9100082738 3 - Average BR1 Luxembourg, REFEH2 not lit
PF9100100805 3 - Average SW-INTERNAL Improve the fix109695
PF9100100808 3 - Average Undo CR 33118
PF9100100366 3 - Average SMIC6: Enter of CF98 with Er_4
PF9100100747 3 - Average BR3 AU: Door doesn't close if JNFF-S is pressed
PF9100100643 2 - Major Consistency check failed - PHS bouncing not
detetcted
PF9100100868 3 - Average Bootloader: wrong programming of image when odd
size.
PF9100082743 2 - Major door errors - not logged and not transmit to
TM4
PF9100082758 2 - Major after configuring JDE the acknowledge is not
working
Improvement
-------------
Known limitations:
------------------
Notes:
------
New bootloader must be installed for checksum (PF9100100868)
V9.3.15
-------
Delivered (d/m/y):29/03/2007
PC/NT : S00x.exe, 7,159,855 bytes
N/A
- New functionality: -
----------------------
PF9100081008 3 - Average Remove old code for extended diagnostics
PF9100082632 2 - Major Yaskawa interface support 2nd part and
improvements
PF9100082683 3 - Average Yaskawa interface: monitor all available
parameters
PF9100082703 4 - Minor Add to command interpreter: new messages to
sdic5/4 to support improved production tests and other items
PF9100082715 3 - Average BR1 EN81-73 TypeC
PF9100082720 3 - Average Add additional semi-automatic door types
PF9100100675 3 - Average Add Bibobus automatic configuration command
PF9100100702 5 - Enhancement LR on all landings : small optimizazions
PF9100100703 2 - Major LBF: remove limitations for activation
PF9100100774 3 - Average ETM: cmd interpreter function for init strings
PF9100100776 3 - Average ETM: ATM1LxE0 command x must be variable
PF9100100800 3 - Average Show the application checksum at statrup
PF9100081013 2 - Major Move StartupCommonBL from ClosdeLoop drive to
CommonDrive
PF9100100634 3 - Average RESUBMITTED AAT KNE test does not allow
measuring the car displacement
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100065774 5 - Enhancement Terminal values not correct
PF9100081012 1 - Critical ISCPU1 does not start up after erasing
EEPROM and RESET
PF9100082654 3 - Average HYD: SAB: "--" overwritten by car position if
HYD parking to level 1
PF9100082673 3 - Average BIO-Bus scan failure undetected
PF9100082677 3 - Average BIO-Bus LOP count secure input failure
PF9100082678 3 - Average BIO-Bus SCIC.DIP6 assert
PF9100082701 3 - Average Contact Earthquake and Sprinkler Recall works
as N.O. on CAN_IO Board
PF9100082723 3 - Average Sys_info crashes if custom door type is
selected
PF9100082728 2 - Major KA policy not working with BMK mapped buttons
PF9100082732 3 - Average Fire services RESET behavior
PF9100091071 3 - Average ETM RMCC Communication Bugfixes
PF9100091117 2 - Major ETM: Wrong time conversion
PF9100099115 3 - Average Bionic5: Duplex - Floor Call not shifted to
other Elevator when blocked
PF9100099116 3 - Average Bionic 5 Duplex: Motor Overtemperature causes a
watchdog reset
PF9100099349 3 - Average SMIC6: display of HMI shall include the car
position, speed, door status, etc
PF9100100334 2 - Major CW in douplex missbehaviour
PF9100100511 3 - Average Automatic Car Light duplex: light on on wrong
cabin
PF9100100578 3 - Average Wdog led does not blink
PF9100100589 3 - Average BR2 CN & HK-A & BR3 BE & BR4 HK-C: Deactivation
with closed doors on fire recall floor
PF9100100594 3 - Average RESUBMITTED the elevator doesn't go in fatal
error if XKBV is disconnected before/during learning
PF9100100641 3 - Average incorrect delayFor call
PF9100100645 2 - Major Attendant Service (LI) is active, AAT service
can not be activated.
PF9100100658 2 - Major Not possible to exit LOP Configuration with DT-
O
PF9100100659 3 - Average is not possible to leave montage 105
PF9100100666 3 - Average ETM: command for testing with external modem
PF9100100696 3 - Average In a shaft with 20 floor, is not showed the nr
20 on the COP & LIN
PF9100100700 3 - Average enter menu 40 during synchro, HMI become
blocked
PF9100100705 3 - Average TM4 test trip is not executed on COP4
PF9100100731 3 - Average Command 22 is not erasing the Policy option
PF9100100745 3 - Average LOP configuration info not showed completely in
terminal
PF9100100749 3 - Average ETM: CLSD modem reset and LF char
PF9100108301 3 - Average E_HALF_BRAKE_DOWN_INSUFFICIENT_SHAFT_HEIGHT not
implemented
PF9100109695 2 - Major Learning trip after JH off/on each 10times
Improvement
-------------
Known limitations:
------------------
Notes:
------
SCIC51 is NOT released for tests.
V9.3.14
-------
Delivered (d/m/y):09/03/2007
PC/NT : S00x.exe, 7'159'855 bytes
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100100647 1 - Critical Safety Chain Supervisor not Working
PF9100100628 3 - Average SW-INTERNAL protect with mutex cancel timer
function
PF9100082702 2 - Major LOP acknowledge not working
Improvement
-------------
Known limitations:
------------------
- Write EEPROM problems: shaft image is sometimes lost, a learning is invoked
Notes:
------
V9.3.13
-------
Delivered (d/m/y):2/03/2007
PC/NT : S00x.exe, 7'159'855 bytes
N/A
- New functionality: -
----------------------
PF9100100278 3 - Average Resubmitted: LR on old landings
PF9100033118 3 - Average FC package goes in timeout with no apparent
reason
PF9100098562 3 - Average COP5 AP:COP_DIAGNOSTIC_DATA stir up a lot of
CAN messages
PF9100100442 3 - Average ETM Refactory, second part
PF9100082611 3 - Average Treat floor ack as BMK
PF9100082670 3 - Average Additional MOD door type 86 and 87
PF9100081002 3 - Average Error handling for new EmbeddedRM EEPROM files
PF9100081001 4 - Minor Remove gcc compiler warnings
PF9100080999 3 - Average Menu 308
PF9100082547 4 - Minor No parking after too long reversing
PF9100080998 3 - Average Menu 126
PF9100081004 3 - Average F89 after 10 times in an hour fatal
PF9100100521 3 - Average Show the CPLD version in system info
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100100306 3 - Average Arrows are cleared with car-DTO
PF9100032957 3 - Average Cop5B_10 KS-Display doesn't update correctly
when car calls are pending and Configuration is activated via HMI.
PF9100080462 3 - Average Submitted BR1-UK, Car light remains ON
PF9100100604 3 - Average ETM: HW Flow control
PF9100100527 3 - Average Trigger correction in case of
E_TRIP_POSITION_TARGET_NOT_REACHED
PF9100108912 3 - Average CF40 doesn't answert to SPECI menu commands
PF9100098944 3 - Average SW_INTERNAL: remove log writes connected to TSD
service.
PF9100079222 3 - Average Advanced diagnostic - After inspection OFF
diagnostic mode is deactivated
PF9100100315 2 - Major SMIC6: TSD activation not possible
PF9100099445 3 - Average Impossible to relate errors and logs
PF9100100559 3 - Average Uninitialized pointer cause crash with WinSim
PF9100081007 2 - Major Support byte alignment for structs in eCos OS
PF9100081006 2 - Major Support Byte alignment for structs in eCos OS
PF9100100569 3 - Average timer manager flawed
PF9100100518 2 - Major Fire and JAB active cause reset loop
PF9100100517 2 - Major Reservation and JAB active cause reset loop
PF9100100525 3 - Average Wdog reset (LOOP) at start-up, SIM card problem
PF9100098531 3 - Average SW INTERNAL:Remove use of MAX_NR_OF_LARGE_MSGS
PF9100098743 2 - Major VCA, the voice announcement is not made in
deceleration phase
PF9100100575 2 - Major Advanced Diagnostic -BR does not overide
Diagnostic service
PF9100100498 3 - Average SW-INTERNAL: skip the remove of invalid timer
Ids
PF9100100497 3 - Average Assertion in MsgMgr line 170
PF9100100499 3 - Average SW-INTERNAL- Avoid to delete invalid timers
PF9100100389 2 - Major SMIC6: deactivation of inspection while BRx is
active
PF9100100587 1 - Critical Not possible to perform SW update with
MMC 256 MB available in production
PF9100080551 3 - Average Resubmitted AAT, KNE test, motor doesn't stop
if the KNE isn't positioned correctely
PF9100100529 3 - Average FC Monitoring: HMI menu 70 doesn't work
PF9100100583 3 - Average SW_INTERNAL Eeprom writes lead to possible
blocking
PF9100100584 1 - Critical SW-INTERNAL: the wdogsupervisor cannot
trigger a reset
PF9100100576 3 - Average RBV output is not driven
PF9100109623 1 - Critical Startup problem with TM4 exernal
connected on XTELE
PF9100100477 1 - Critical Door heartbeat is not handled
PF9100099184 1 - Critical Missing heartbeat from controller to FC
PF9100100373 1 - Critical Fan control without SIAP
PF9100108377 3 - Average FC Monitoring: HMI menu 70 doesn't work
PF9100100619 2 - Major SW INTERNAL- EEPROM write test
PF9100100312 3 - Average SMIC6: Montage activation and deactivation
Improvement
-------------
Known limitations:
------------------
- Write EEPROM problems: shaft image is sometimes lost, a learning is invoked
Notes:
------
V9.3.12
-------
Delivered (d/m/y):20/10/2006
PC/NT : S00x.exe, Not released
- New functionality: -
----------------------
PF9100099051 6 - not applicable Yaskawa CL IF supported
PF9100080985 3 - Average DNS for Embedded RM
PF9100100330 5 - Enhancement BR2 Hong Kong New SIM Card Option for V9.3
PF9100082542 3 - Average BR2 HK-A
PF9100091030 3 - Average BR1 EN-81-73 (Type A/B/C)
PF9100090948 3 - Average Handicapped Operation (BF) for TW & KR
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100090987 1 - Critical JSPS BMK Code is wrong
PF9100082567 4 - Minor SAB activation while serving call - "--" not shown on
LOP/LIN and COP
PF9100090974 1 - Critical BR3 Korea doesn't open the door after
evacuation
PF9100090993 4 - Minor BR1 (CH), Policy DE: SUMC gets active while the door
is closing
PF9100090985 3 - Average Change FAKE_24V_OK from BMK to PRIVATE input
PF9100100396 3 - Average Sprinkler Recall option in V9.3
PF9100100320 3 - Average MSG_CAR_MOVE_EXCEPTION_CAUGHT does not trigger
correction
PF9100082596 3 - Average FMT test failure step 36
PF9100082571 3 - Average Independ Control service does not resume correctly
after an emergency stop.
PF9100082570 3 - Average FMT test failed at step 100b
PF9100082573 3 - Average BR1/2 SG-A KTHMT is ignored
PF9100082564 3 - Average PA4: After parking no more calls are executed
PF9100082551 3 - Average Start-Up errors are not notified to TM4
PF9100082553 3 - Average remove windview from Bsp
PF9100108240 3 - Average Process Node correction necessary due to msg mgmt
PF9100081000 3 - Average Speci waiting view enumerators wrong
PF9100108296 3 - Average Pre-torque test (menu 123) bottom/top doesn't work
PF9100100298 2 - Major quick activation and deactivation of the JAB leads to
somewhat blocked elevator
PF9100099103 2 - Major Motor and brake resistor overtemp do not perform
emergency landing
PF9100090971 1 - Critical Bio2 Slave not scanned
PF9100080997 2 - Major LOPMgr state blocks synchro while opertion
PF9100108008 2 - Major BR1 KR - After start up multiple watch dog reset
PF9100082589 2 - Major preopening commanding with short interfloors
Improvement
-------------
PF9100100280 3 - Average problems LOP configuration &/or LOP teaching (Bio2
master)
PF9100082578 3 - Average SDIC4: Restore state of aux. outputs
PF9100080996 3 - Average Remove [-DTO] functionality from the configuration
over COP device
PF9100082565 3 - Average Reestablish monitor protection for logging
PF9100082562 3 - Average Round Robin Scheduling for vxWorks
PF9100100308 3 - Average ETM: Ricci's activities re-alignment to 9.3.11
Known limitations:
------------------
- Call simulation does not work
- After 100 trips SW crashes
Notes:
------
Delivered (d/m/y):20/10/2006
PC/NT : S00x.exe 6.75Mb (7'082'031 bytes)
N/A
- New functionality: -
----------------------
PF9100082518 3 - Average BR4NZ
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100033324 2 - Major HydraulicFatalError during Motor over
temperature procedure SW9.22.06
PF9100080294 3 - Average CLC calibration feiled - No error log record
about it
PF9100080984 3 - Average Improvement Debug Business Logic
PF9100082301 3 - Average BR2/3-xxx to return to last floor after reset
PF9100082391 4 - Minor non-automatic doors: RTS ignored at learning
trip start
PF9100082395 3 - Average CF25 for mixed shaftdoors not visible after a
learning trip
PF9100082409 2 - Major Door Out of group
PF9100082433 2 - Major DT-S do not close the door
PF9100082484 3 - Average DTO after finaltimer/nudging closes with
slowspeed
PF9100082489 3 - Average Final timer, the door doesn't close in slow
speed
PF9100082500 2 - Major Task priority inversions caused by LogWriter
monitor
PF9100082504 2 - Major Safefy Chain Interrupted service + Door error
service leads to blocked elevator
PF9100082510 5 - Enhancement Round Robin scheduling for NetARM BSP
PF9100082524 3 - Average VCF - parking with door open timeout
PF9100082527 3 - Average Terminal Slowdown: False triggering in TwoSpeed
drive
PF9100082532 1 - Critical BR1 LU- It can not be activated by
fireContactH2
PF9100082543 5 - Enhancement NetARM BSP update
PF9100082545 3 - Average Door behaviour in fatal error situation
PF9100082548 1 - Critical Round Robin NetARM 50ms
PF9100090957 3 - Average Use Bio2 master as Bio1 master
PF9100098323 3 - Average strange recoverable error while CLC
configuration
PF9100099111 3 - Average Door closing with final timer and KSKB gets
acitve: SUMC still active
PF9100099331 3 - Average Missing FC monitoring function
PF9100099749 3 - Average Extensions to better support FC application
PF9100100173 3 - Average Disabling CLC via SIM CARD
PF9100100233 3 - Average DBV input is inverted, second part
PF9100100235 1 - Critical Watchdog supervisor doesn't lead to a SW
reset
PF9100100244 1 - Critical Safety chain interrupted annd elevator
blocked cause by wrong call management
PF9100100255 3 - Average Allow the call simulation top-bottom to open
the doors
PF9100100272 2 - Major Assertion MsgMgr line 170
PF9100107280 3 - Average Resubmitted: Arrival gong GA2, PI policy, car
call are announced
Improvement
-------------
Known limitations:
------------------
Notes:
------
V9.3.10
-------
Delivered (d/m/y):12/10/2006
PC/NT : S00x.exe 6.67Mb (7'000'111 bytes)
N/A
- New functionality: -
----------------------
PF9100099240 COP5 AU Mechanical support
PF9100100112 SHOW_LOP_STATE command
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100049646 Add CE125 and low power machine to FA6
PF9100049651 FA Brake Monitoring for ZLA-MOD: error, parameter, door
operation and alarm.
PF9100049653 FA Brake Monitoring for ZLA_MOD: brake parameter must
support also CL drive.
PF9100082091 Car partition door: Malfunctions
PF9100082343 After command ENABLE_IO_NOTIFICATION inspection mode fails
PF9100082362 CL: Synchro + Overtemperature + semi-automatic doors: Door
remains blocked
PF9100082401 Non automatic doors: door lock not released in fatal error
PF9100082430 Contact Earthquake works as N.O.
PF9100082434 Add SCOPMHL3 to the list of COPH devices
PF9100082491 Separation of JBF and KBF Message
PF9100090817 update 9.2x.xx bugfixes in 9.3.xx
PF9100090860 NS21 remain forever activ
PF9100090864 ETM HW Intergation of PPP and SSL
PF9100098588 KETO not working: elevator blocked
PF9100098853 JHSG can't be reset
PF9100098883 Parking Services for AP: New option to have the door(s)
open.
PF9100098893 SW-INTERNAL Remove all sim card specific commands from
common commands
PF9100099128 Resubitted: BR3 Belgium firefighter mode doesn't work
PF9100099230 Releveling shaft info is not erased by montage
PF9100099298 Undo #99297 Duplex scheduled calls recovery with cleaner
solution
PF9100099314 Close the door in Test 64 before requiring the brake plug
PF9100099315 Elevator blocked due to broken temperature sensor
PF9100099386 Safety chain persistently bridged wrong error detection
blocks elevator
PF9100099392 Change speed protections fro SGEC test test never
successful
PF9100099398 After KTHMH activation Elevator doesn't stop as soon as
possible.
PF9100099405 Elevator blocked due to safety chain opening
PF9100099416 Fatal error caused by saftety chain interrupted at the end
of syncro trip
PF9100099432 CL + Relevelling: Emergency stop leads always to Synchro
PF9100099441 Integrate cr PF9100108311 and PF9100099078 corrected by BBV
PF9100100011 BR3 (KR) - Ending Phase - Car Not in the Right Position
PF9100100048 FC not commissioned with SIM card file system 6 and ACVF
param 4
PF9100100049 System info must list also the new sim card options
PF9100100051 Invalid log of E_FC_DRIVE_PHASE
PF9100100071 GS: Stop on recall panel is active, door closes anyway when
GS floor is the destination
PF9100100078 KB/KB1 disabling parameter is accessible on non mod
installations
PF9100100079 CL + relevelling: system blocked after emergency stop
PF9100100086 re-leveling assertion
PF9100100089 AAT 26: Door Opening Speed not working/ error at test end
PF9100100090 AAT 75: assertion during AAT safety gear
PF9100100091 AAT 32: Car impact on Buffer doesn't work
PF9100100100 EEPROM written at each trip
PF9100100101 Elevator blocked after SW update
PF9100100105 Elevator blocked Safetychain recovery not working
PF9100100109 Safety chain persistently bridged wrong error detection
PF9100100117 Duplex, one elevator blocked during a call, the call not
served by the other
PF9100100136 Elevator blocked by FC fault
PF9100100139 Door doesn't open In door Zone after reset if elevator is
in fatal error
PF9100100140 Fully manual doors: Elevator blocked with Car Call in "E"
PF9100100141 Assertion in "policy"
PF9100100144 during configuration the COP is not in 10-Key-pad
PF9100100147 Elevator blocked with opened door
PF9100100151 one reset at start-up if the eprom is erased
PF9100100155 Trip Target not reached error blocks system
PF9100100161 DBV input is inverted
PF9100100164 System resets on all platforms
PF9100100184 B5 AP: Re-Leveling, PHNR U/D signals lost, Elevator not in
Fatal Error
PF9100100186 KB/KB1 assertion
PF9100100189 Door max lock time in case of failed emergency landing due
to KB error
PF9100100191 Elevator blocked due to KB error during releveling
PF9100100193 Wrong error message registration with Releveling CL
PF9100100195 after synchro, service Synchronization
waitingForDeactivation
PF9100100197 Duplex UI: in PI elevator clear all LOPs ack if error
occour
PF9100100198 CAN: too many messages sent to COPH
PF9100100199 Full load is signalized without the option in SIM card
PF9100100200 door opening witout carlight swithing on
PF9100100203 Resubmitted - HMI configuration for LLV/LRV/LUB on SAIO-
ECUMR
PF9100100204 Added some infos of car
PF9100100206 Elevator blocked due to wrongly detected
E_TRIP_PHSx_SIGNAL_PERSISTENTLY_BRIDGED
PF9100107645 LBFC lamp fire service active (in car) doesn't work
PF9100107736 At start-up the elevator finds the EB active --> assertion
PF9100107789 ZBCE doesn't lock the floor with JSPS
PF9100108028 Losing Re-Leveling Signal during traveling. ELEVATOR
doesn't enter in Fatal Error.
PF9100108235 Entering of AAT37 - reset occurs and entering of 32
elevator is blocked
PF9100108249 Resubmitted: BR4 MY Elevator in firefighter mode. Door
closing by Car call
PF9100108277 Contact Sprinkler Recall KSR works as N.O.
Improvement
-------------
Known limitations:
------------------
Notes:
------
V9.3.09
-------
Delivered (d/m/y):31/10/2006
PC/NT : S00x.exe (6'946'863 bytes)
N/A
- New functionality: -
----------------------
PF9100049637 Two Speed Drive Brake Monitoring for ZLA-MOD.
PF9100082077 Doors: Special KSKB handling for BR2SG
PF9100082300 Restricted Access for ZLA
PF9100090794 ETM Refactor Internal Structure
PF9100098700 Modem handling Impl.: Initialization and startup with fix value
on HW
PF9100099192 ETM detection: Modem Automatic Configuration
PF9100099208 New SIM Card Options for V9.3 release
Integration tests:
------------------
Bugfix Corrected:
-------------
PF9100049639 Synchronization Trip don�t get started
PF9100065746 re-leveling UP/DW enabled when KNE-U active
PF9100069689 The fatal error 0402 would generated after TC1006
PF9100078938 Policy DE 2nd Car Call
PF9100080345 Test trip [20 --]
PF9100080511 Resubmitted the car doesn't change direction as soon as possible
while I activate the fire service
PF9100080534 Resubmitted - NS 21: LNOC is in special combination not
Resetproof (does not switch ON)
PF9100080605 Resubmitted BR3 Australia Earthquake Generic operation. While the
car is moving inside the door zone, KEB becomes active
PF9100082358 SCIC3: SIM card not programmable
PF9100082359 Resubmitted: Control is sending wrong unbalance value in Safety
geat acceptance test
PF9100082360 PI, DE car call acknowledges not canceled
PF9100082361 Motorventilation CL: Malfunctions
PF9100082363 SHBT service not deactivating, elevator blocked
PF9100082364 SHBT blocked in certain situations
PF9100082365 SHBT deactivation car call not performed
PF9100082368 SHBT deactivation: sometimes more than one car calls required for
deactivation
PF9100082369 SCIC - Reset withl car between floors triggers a Fatal error
PF9100082371 SHBT with door types 59 and 60: door lock released in preopening
PF9100082377 KEB / KGEB are only working with SLCUX
PF9100082378 SAB is not Reset proof
PF9100082379 2 x COPH: No car call ack. on secondary COPH
PF9100082380 Montage-Service DIP8 + Inspection up/down -> reset
PF9100082384 TM4 and Service PC connected at the same time => Inspection
travel fails (2) V9.22
PF9100082397 Restricted Access for ZLA - deactivation makes reset
PF9100082406 Door type 52: Problem in Inspection/Recall
PF9100098477 assertion If N_ISF is disconnected before a call
PF9100098937 Elevator blocked due to wrong KSE signal processing
PF9100099052 System blocked in LOP count if no lop connected
PF9100099064 Resubmitted ISCPU: COPH is not recognized during learning trip
PF9100099158 ETM: changing from external TM4 to embedded TM cause a reset
PF9100099175 SMIC6,Is not possible to do LOP count
PF9100099193 EEPROM written at each trip
PF9100099212 Possible elevator damage due to not handled KB error
PF9100099222 version 9.3.08 does not work on motorola 68k
PF9100099225 SW_INTERNAL reorder TASK priorities according to layers
PF9100099239 Download of the SIM card parameters is not working
PF9100099266 CF40 and CF41 are not working with SPECI, BL does not answer
PF9100099291 Node dead for 0006
PF9100099292 re-leveling is ruinning, AAT become active, elevator do strange
emergency stop
PF9100099293 Passenger trapped after a KB error
PF9100099328 State paralllel drive in system info
PF9100099364 Update the safety chain check (lift guard) to support SMIC6
PF9100099442 Add 2nd COP to SHOW_COP_STATE command
PF9100107309 RNO works as N.O. input
PF9100107641 GS combinated with ZB3 does not work
PF9100107964 Deactivation door overtemperature condition. Timer does not
expire
PF9100108053 BR1UK - 3 - Evacuation - Car light and car fan do not shut down
PF9100108108 BR3 Australia Fire Service deactivation is impossible
PF9100108444 activation/deactivation TSD in montage mode cause fatal error
Improvement
-------------
PF9100082018 E_DOOR_SHAFT_ERROR leads to fatal error
PF9100082273 Service Montage: Safety Chain Status not checked before trip
PF9100082342 Restricted Access for ZLA (2)
PF9100082382 New Restriction on usage of LUET signal
PF9100099171 CF19 for 6FA via Command Interpreter
PF9100107850 P-Care: Disable enhanced service functions after 10'000 trips
PF9100099200 SW_INTERNAL: update lauterbach files to allow proper debugging
Known limitations:
------------------
Notes:
------
V9.3.08
-------
Delivered (d/m/y):12/09/2006
PC/NT : S00x.exe (5'533'743 bytes)
SCC5_903.BIN checksum: $
SCC5_903.BIN file length:
SC51_903.BIN checksum: $
SC51_903.BIN file length: $
N/A
- New functionality: -
----------------------
Integration tests:
------------------
Bugfix Corrected:
-------------
Improvement
-------------
Known limitations:
------------------
Notes:
------
V9.3.07C6
---------
Delivered (d/m/y):23/08/2006
PC/NT : S00x.exe (5'316'655 bytes)
MOTOROLA :
S00x.abs checksum: $0B874FE1
WARNING: OPT and STD are not delivered because the SW does not fit anymore on
SCIC2
NetARM :
scic3_vxw.b checksum: $0C860F85
- Checksum calculated using S4drvwin.exe (binary)
scic3_vxw.b File lenght: $001B5EFC
N/A
- New functionality: -
----------------------
Known limitations:
------------------
Notes:
------
This version is the integration of the V9.3.07
PLUS: WinSim improvement delivered after the release V9.3.07
V9.3.03C6
---------
Delivered (d/m/y):08/08/2006
WARNING: OPT and STD are not delivered because the SW does not fit anymore on SCIC2
SCC5_903.BIN checksum:
SCC5_903.BIN file length:
WARNING: OPT and STD are not delivered because the SW does not fit anymore on SCIC2
SC51_903.BIN checksum:
SC51_903.BIN file length:
scc3_903.bin checksum:
scc3_903.bin file length:
- Checksum calculated using S4drvwin.exe (binary)
scic3_vxw.hex checksum:
scic3_vxw.hex File Bytes:
scic3_vxw.hex File range: $00040000 - $001B611B
- Checksum and additional data above calculated using S4drvwin.exe (motorola hex)
N/A
- New functionality: -
----------------------
- As defined for V9.3.03C1
Known limitations:
------------------
- PF9100098899
- Remove logging in Redboot (startup information). This can be done by switching
off the corresponding
options in Redboot configuration (use ConfigTool).
Notes:
------
Integration tests:
------------------
Bugfix Corrected:
-------------
- Improved BioBus reliability
(biobus.c: reworked the collaboration between ISR, DSR and the serial
driver, to improve the timing.
ser_mcf52xx.c: created a special ISR for the biobus, buffering the
received bytes directly in the ISR)
- KeSe_eCos/Src/Kernel.cpp: Do not allow to create more tasks, than the
array of tasks can hold
- Integrated bugfix for PF9100080959
(ConfigurationLogic40_Lxx.cpp: in the initialization )
V9.3.03C4
-------------------------
Delivered (d/m/y):21/07/2006
This version is based on the official S00x V9.3.03C2 received from Schindler
Locarno.
Additionally this version supports automatic mode for SPI
FEATURES:
- As defined for V9.3.03C1
- Made software compilable for win32 (Simulation environment)
BUG FIXING:
- PF9100098913 ("command show_task_id does not work")
- PF9100098907 ("KNEt contact is inverted")
- PF9100098849 ("is not possible to configure the ECU-SAIO with")
- PF9100098927 SMIC6: automatic evacuation causes fatal error
OPEN ITEMS:
- PF9100098899
- Remove logging in Redboot (startup information). This can be done by
switching off the corresponding
options in Redboot configuration (use ConfigTool).
BUGS:
V9.3.03C3
-------------------------
Delivered (d/m/y):17/07/2006
This version is based on the official S00x V9.3.03C2 received from Schindler
Locarno.
Additionally this version supports the hardware flow control for the new BioBus.
FEATURES:
- As defined for V9.3.03C1
BUG FIXING:
OPEN ITEMS:
- PF9100098899
- Automatic SPI mode for SMIC6
- Remove logging in Redboot (startup information). This can be done by
switching off the corresponding
options in Redboot configuration (use ConfigTool).
BUGS:
V9.3.03C1
-------------------------
Delivered (d/m/y):11/07/2006
This version is based on the official S00x V9.3.03 received from Schindler Locarno.
Additionally we have integrated the biobus, the cpld bus driver, the support of the
SMIC6 IOs and support
of SMIC6 display to render the same functionality as SMIC5
FEATURES:
- BioBus supported
- BBCtrl support new biobus driver
- support of SMIC6 IOs
- support of LCD display
bug fixing:
OPEN ITEMS:
- Test of SMIC6 environment
BUGS:
- Biobus implementation works not stable because CTS/RTS flow control doesn't
work with the actual CPLD version (V1.01)
Reason: unknown
V9.3.03
--------
Delivered (d/m/y):08/05/2006
MOTOROLA :
S00x.abs checksum: $0C24A8F5
WARNING: OPT and STD are not delivered because the SW does not fit anymore on
SCIC2
NetARM :
scic3_vxw.b checksum: $0C3CDCB2
- Checksum calculated using S4drvwin.exe (binary)
scic3_vxw.b File lenght: $001AD630
Shaft Image
- KS Shaft Image FILE_SYS_VERSION1_NORMAL
- PHS Shaft Image FILE_SYS_VERSION2_NORMAL
Revision Number FILE_SYS_VERSION1_NORMAL
Error Log FILE_SYS_VERSION1_NORMAL
Statistics File FILE_SYS_VERSION1_NORMAL
Drive Parameters
- Closed Loop DRIVE_CL_NORMAL_FILE_VERSION_01
- Hydraulic DRIVE_HYD_NORMAL_FILE_VERSION_01
- Two Speed DRIVE_TS_NORMAL_FILE_VERSION_01
Modernization Parameter MODERNIZATION_NORMAL_FILE_VERSION_01
Basis Normal File BASE_CNFG_NORMAL_FILE_VERSION_01
Password File PASSWORD_CNFG_NORMAL_FILE_VERSION_01
Traffic Controller Parameter TRAFFIC_CNFG_NORMAL_FILE_VERSION_01
LOP Parameter LOP_CNFG_NORMAL_FILE_VERSION_01
COP Parameter (N) COP_CNFG_NORMAL_FILE_VERSION_01
Basis Secure File (S) BASE_CNFG_SECURE_FILE_VERSION_01
Extended Normal File (N) EXTENDED_CNFG_NORMAL_FILE_VERSION_01
Extended Secure File (S) EXTENDED_CNFG_SECURE_FILE_VERSION_01
Door Parameter (N) DOOR_CNFG_NORMAL_FILE_VERSION_01
- New functionality: -
----------------------
PF9100082138 3 - Average VCA to announce door movement
PF9100098629 3 - Average Change "CO" during COP password promt
PF9100065841 3 - Average MNU-1-Riser
PF9100082085 3 - Average Parking Services for AP: New option to have the
door(s) open.
PF9100082083 3 - Average Add log messages in case of Reset and Power-Up
PF9100082086 3 - Average SR(NZ): Shunt Trip, Sprinkler Recall Trip
PF9100082084 3 - Average NTSD(MTL): Terminal Slowdown for CL
PF9100082180 3 - Average BR1 (HK) Type B, BR4 (HK) Type C
PF9100082142 3 - Average SCIC5: CAN Extended Frames
PF9100090560 3 - Average MNU one riser in Landing Panel
PF9100098501 5 - Enhancement GSC Floor passing Chime in Car
PF9100098502 5 - Enhancement LR on all landings
PF9100098521 5 - Enhancement New SIM card options on SCIC
PF9100065975 5 - Enhancement Extend error log size on SCIC5
PF9100090617 5 - Enhancement IOController Intermediate
PF9100090668 5 - Enhancement LR on all landings
PF9100080909 AAT: Counterweight impact on Buffer
PF9100080910 CF40
PF9100080912 COP5 teaching for 25 floors
PF9100080924 Some shaft stages for Telemonitoring not available
PHNR
PF9100080928 AAT Half Brake Test with parameter brake distance
implementation
PF9100080930 AAT, 75 Safety Gear Car (empty car) is missed the
step "ready to run"
PF9100080932 HMI - Menu 20 available for BX FA and BX HY
Known limitations:
------------------
Notes:
------
Integration tests:
------------------
CR Validated:
-------------
PF9100098460 1 - Critical System blocked due to concurring
correction and safety chain interrupted
PF9100082107 1 - Critical FA system always and only travels
downwards
PF9100098472 1 - Critical elvator-pump does not start-up (RFR relay
not active)
PF9100079024 2 - Major SCIC - Reset allows opening car door between
floors
PF9100082193 2 - Major Load Switches not working
PF9100098348 3 - Average releveling flags disturb normal behavior
PF9100065865 3 - Average Door timers for KSKB and RPHT are ignored.
PF9100080287 3 - Average ZB1- TM4 test trip is not executed if car is
below a protected floor
PF9100098474 3 - Average the elevator doesn't go in fatal error if XKBV
is disconnected before/during learning
PF9100065908 3 - Average Negative error count in error list
PF9100065777 3 - Average Car controller race conditions
PF9100065974 multiple TM4 breakdowns because of a door error
PF9100080914 CBD insptection with KSE_UD shaft - speed not correct
set
PF9100080922 Elevator blocked with no recovery possible W/O
terminal
PF9100080923 Bionic 5 AP: Car doesn't travel in Leveling Speed
inside End Shaft Zone
PF9100080929 Exiting of CF 86 ( by "-" "DTO" cause assertion
PF9100098458 Bionic 5 AP: Car doesn't travel in Leveling Speed
inside End Shaft Zone
Delivered (d/m/y):05/04/2006
MOTOROLA :
S00x.abs checksum: $0xxxx
WARNING: OPT and STD are not delivered because the SW does not fit anymore on
SCIC2
SCC5_903.BIN checksum: $0xxx
SCC5_903.BIN file length: $00xxx
NetARM :
scic3_vxw.b checksum: $0xxx
- Checksum calculated using S4drvwin.exe (binary)
scic3_vxw.b File lenght: $00xxx
Shaft Image
- KS Shaft Image FILE_SYS_VERSION1_NORMAL
- PHS Shaft Image FILE_SYS_VERSION2_NORMAL
Revision Number FILE_SYS_VERSION1_NORMAL
Error Log FILE_SYS_VERSION1_NORMAL
Statistics File FILE_SYS_VERSION1_NORMAL
Drive Parameters
- Closed Loop DRIVE_CL_NORMAL_FILE_VERSION_01
- Hydraulic DRIVE_HYD_NORMAL_FILE_VERSION_01
- Two Speed DRIVE_TS_NORMAL_FILE_VERSION_01
Modernization Parameter MODERNIZATION_NORMAL_FILE_VERSION_01
Basis Normal File BASE_CNFG_NORMAL_FILE_VERSION_01
Password File PASSWORD_CNFG_NORMAL_FILE_VERSION_01
Traffic Controller Parameter TRAFFIC_CNFG_NORMAL_FILE_VERSION_01
LOP Parameter LOP_CNFG_NORMAL_FILE_VERSION_01
COP Parameter (N) COP_CNFG_NORMAL_FILE_VERSION_01
Basis Secure File (S) BASE_CNFG_SECURE_FILE_VERSION_01
Extended Normal File (N) EXTENDED_CNFG_NORMAL_FILE_VERSION_01
Extended Secure File (S) EXTENDED_CNFG_SECURE_FILE_VERSION_01
Door Parameter (N) DOOR_CNFG_NORMAL_FILE_VERSION_01
- New functionality: -
----------------------
This release adds new IOhandler
It is an internal release. Not official binaries are released.
Known limitations:
------------------
Notes:
------
Integration tests:
------------------
CR Validated:
-------------
id Headline
V9.3.00a+
-------------------------
Delivered (d/m/y):09/06/2006
This version is based on the official S00x V9.3.00a received from Schindler
Locarno.
Additionally we have integrated the new IO-Handling mechanism frfom Viktor
Wunderlin
FEATURES:
- Supports following HW:
SMIC31, SMIC5, SHMI, SAIO, MCCH1, MCCH2, MCCH3, MCCE1, MCCE2, MCCE31,
MCCE4, MCCE5
- Support of ISCPU1
- Support of RTC including command interpreter commands get_time and set_time
for ECOS_KERNEL only
- BioBus not supported
SynchronisationService has been adapted to ignore the state of BioBus
in order to get elevator starting up
- Added new IO-Handling from Viktor
- Compiles for ECOS, MICROTEC, WIN32 and VXWORKS
- Runs on Motorola, NetArm and Coldfire platform. On PC the application
executes limited functionality due to
the missing IO-Adaptation.
- Implemented Power fail safe EEPROM mechanism
- Support of extended CAN-IDs (tested with HY simulator and CANIO)
- Support switchable SPI voltage
- Support switchable RS232 interface
- Bootloader: - Supports 16, 32 and 64 MB MMCs
- Support of HWId programming
- Support of CPLD programming
- Support of HWId update concept
according documentation. Similar UI concept has been used for
updating CPLD and application.
OPEN ITEMS:
- Regression test and system function verification (only some simple
engineering test were executed at this time)
- Extensive verification and test of power fail safe EEPROM mechansim
- RTC in ErrorLog not yet supported
- Bootloader: - switch off logging at system startup.
BUGS:
- Switching DIP8 on, leads to an unhandled exception.
Reason: priority inversion protocol for mutex.
Solution: none. Will be examined and corrected in one of the
next iterations.
- System_info leads to an reset on CL-Sim, a blocked terminal on HY-Sim
Reason: unknown (must be analysed in one of the
next iterations)
Solution: unknown
V9.3.00
-------------------------
Delivered (d/m/y):13/03/2006
MOTOROLA :
S00x.abs checksum: $0CF6503A
- (BDI) Memory filled with FF BEWARE !! now memory size is 0x200000
- Checksum calculated (using BDI) for all the memory size (START ADDRESS0000
0000/END ADDRESS 001F FFFF)
(Type BYTE /Destination LONG)
- On the terminal you can see this checksum at startup.
WARNING: OPT and STD are not delivered because the SW does not fit anymore on
SCIC2
NetARM :
scic3_vxw.b checksum: $0BE102BC
- Checksum calculated using S4drvwin.exe (binary)
scic3_vxw.b File lenght: $001A320C
Shaft Image
- KS Shaft Image FILE_SYS_VERSION1_NORMAL
- PHS Shaft Image FILE_SYS_VERSION2_NORMAL
Revision Number FILE_SYS_VERSION1_NORMAL
Error Log FILE_SYS_VERSION1_NORMAL
Statistics File FILE_SYS_VERSION1_NORMAL
Drive Parameters
- Closed Loop DRIVE_CL_NORMAL_FILE_VERSION_01
- Hydraulic DRIVE_HYD_NORMAL_FILE_VERSION_01
- Two Speed DRIVE_TS_NORMAL_FILE_VERSION_01
Modernization Parameter MODERNIZATION_NORMAL_FILE_VERSION_01
Basis Normal File BASE_CNFG_NORMAL_FILE_VERSION_01
Password File PASSWORD_CNFG_NORMAL_FILE_VERSION_01
Traffic Controller Parameter TRAFFIC_CNFG_NORMAL_FILE_VERSION_01
LOP Parameter LOP_CNFG_NORMAL_FILE_VERSION_01
COP Parameter (N) COP_CNFG_NORMAL_FILE_VERSION_01
Basis Secure File (S) BASE_CNFG_SECURE_FILE_VERSION_01
Extended Normal File (N) EXTENDED_CNFG_NORMAL_FILE_VERSION_01
Extended Secure File (S) EXTENDED_CNFG_SECURE_FILE_VERSION_01
Door Parameter (N) DOOR_CNFG_NORMAL_FILE_VERSION_01
- New functionality: -
----------------------
This is the first release with new message managment, based on V9.2.04
Known limitations:
------------------
Notes:
------
Integration tests:
------------------
CR Validated:
-------------
id Headline