JG-INS-ANA-020
L0
Questions
The ABB distillation analysers correlate to which ASTM standard?
What is the length of the heater required to be adjusted in the boiler?
What is the distance between the tip of the thermocouple and the final coil of the heater in the distillation analyser.?
What is the flowrate required to be set for sample inlet pump in the distillation analyser?
What is the flowrate required to be set for sample outlet pump in the distillation analyser?
The Naphtha distillation analyser uses anticoking agent-
What is the PM frequency for diesel distillation analyser?
What is the wattage of the high temperature heater version in the distillation analyser?
What thermocouple is used in the distillation analyser?
Before doing maintenance on the distillation analyser the purge control mode should be switched to Maintenance mode
What is the ratio of anticoking agent to sample used in distillation analyser?
The _____________ heater version is used in Naphtha distillation analyser-
What is the limit of the sample temperature at the analyser input?
Depending on the level in the tranquiliser well, the pre-amp card generates an output voltage of ?
The LIC shows 0-100% indication for an input voltage of?
The air purge exit module lid opening is generally set at 20 mbars- True or False.
What is the maximum stroke frequency of the pneumatic anticoking pump ?
The hydraulic oil required to be filled in the sample pumps is Pulsa lube 8 G – True or False.
The pressure on the pressurization guage in the purge control unit is set at 2.5 bars -True or False.
The pressure on the purge guage in the purge control unit is set at
When will the RED indicator be ON in the purge control unit ?
When will the GREEN indicator be ON?
When will be the YELLOW indicator be ON ?
The sample pressure at the inlet of the analyser is normally set at ________ bars.
The diaphragm is located in the ______________ assembly of the sample pumps.
The ________ valve is to be pressed to remove gases from the hydraulic system of the pump.
The oil used in the gear box section of the pump is Pulsa lube 8 G.
The ABB distillation analyser can be used to measure distillation in the range of 0 to 100 %.
The heater can be switched ON even if the pumps are OFF
What is the PM frequency for Naphtha distillation analyser?
What is the PM frequency for LK distillation analyser?
What is the PM frequency for HK distillation analyser?
In the cooling cycle ,the sample in the sample cup is cooled with the help of _____.
The pendulum with mirror is located in the center of the cup
During the cooling cycle, the charge valve and drain valve are in _____ condition
The supply voltage to the sample cup heaters is______.
The operating sample pressure at the analyser inlet should be _____.
The operating sample flowrate to the analyser should be_____
The operating cooling water flowrate to the analyser should be____
The temperature of the sample in the sample cup is measured by ____
How many temperature probes are installed in the cell box assembly?
The pour point is detected by_____
The position of the pendulum in the sample cup is_____
The photo diode produces output voltage in the range of______
The light source in the pourpoint analyser is a______
The sample cup rotates at the speed of _____
The burette is heated.
The light source supply voltage is____ volts
In the "Flush" sequence, the product valve and the drain valve are____
The motor rotating the cup will be ON in the ______ cycle
In the ____ & ____ cycle, the heater will remain ON
The Unplug sequence starts when the instrument is powered on.
In the flushing sequence the sample is flushed through the sample cup.
The 4 LEDs located on the backplane board in the control box assembly indicate the status of_______.
When the 1st LED ( located in the control box ) from the top is glowing, it indicates that ______ power supply is healthy.
When the 2nd LED ( located in the control box ) from the top is glowing, it indicates that ______ power supply is healthy
What are the two operating modes of the analyser?
Which card is located adjacent to the CPU card?
If the difference between the ramp temperature and the effective cell temperature is higher than _____ deg C, a cooling
Which error is emitted when a pourpoint is detected with a value of more than 3 deg C above previous value.
When the cool-time out error is generated, cooling halts and the analyser switches to ______ state instead of Ready sta
The cooling rate may be set between _______ deg C / min in one minute increments.
If the difference between the ramp temperature and the effective cell temperature is higher than 10 deg C, a cooling err
Option 1 Option 2 Option 3 Option 4
ASTM D 86 ASTM D 56 ASTM D96 ASTM D 92
156 mm 158 mm 120 mm 160 mm
1-2 mm 6 mm 5 mm None
25 ml / min 25 lph 25 nm3 / hr 25 m3 / hr
1.25 lph 1.25 ml / min 1.8 lph None
True False.
3 weeks 8 weeks 15 days 12 weeks
300 watts 1000 watts 500 watts None
K- type R-type S-type J-type
True False.
0.048611111111111 0.090277777777778 0.042361111111111 0.084027777777778
High temperature Cartrige Standard temperature None
> FBP < IBP and also < 65 deg C > IBP None
0 – 2.5 VDC 0 – 5 VDC 0 – 5 VAC 0 – 2.5 VAC
0 – 10 mVDC 0 – 10 VDC 0 – 70 mVDC 0 – 100 mVDC
True False.
45 strokes / min 60 strokes / min 100 strokes / min None
True False.
True False.
2 to 3 4 5 6
10 8 6 1
1 0
Answers
Option 1
Option 2
Option 1
Option 1
Option 2
Option 2
Option 1
Option 3
Option 4
Option 1
Option 1
Option 3
Option 2
Option 1
Option 3
Option 1
Option 1
Option 2
Option 1
Option 3
Option 1
Option 3
Option 2
Option 2
Option 2
Option 2
Option 1
Option 2
Option 2
Option 4
Option 4
Option 1
Option 2
Option 1
Option 3
Option 2
Option 1
Option 2
Option 3
Option 4
Option 4
Option 1
Option 4
Option 3
Option 2
Option 2
Option 1
Option 2
Option 1
Option 3
Option 3
Option 3
Option 3
Option 1
Option 1
Option 2
Option 2
Option 1
Option 1
Option 2
Option 2
Option 4
Option 4
Option 1
Option 1
Option 1
Option 2
Option 3
Option 1
Option 3
Option 2
Option 2
Option 1
Option 1
Option 1
Option 2
Option 3
Option 1
Option 2
Option 1
Level L0
Sr no Questions Option 1
The courier 10 sxt sulphur in liquid analyser works on which
1 NDIR
principle
2 What is the full form of XRF? Xray fluorescence
3 What is the material used as reference std by the analyser Berylleum
Which element is a major inrterference in Sulphur
4 Nitrogen
measurement
Which purge gas is used to purge out argon from the sample
5 Nitrogen
cell?
When the sample cell is opened for maintenance, the Xray will
6 1
be automatically shut down
7 Which is the type of detector used in courier 10 sxt? Proportional counter
8 The sample cell window is made of which material? Titanium
9 The thickness of the Be window is______. 1 mm
The _______ is located between the protective window and
10 Proportional counter
the Be window.
What is the maximum sample pressure rating for the sample
11 1 bar
cell?
What command is used to open communication with the
12 A
analyser?
What is the command used to bring the analyser to active
13 1+
mode from passive mode?
The _____ paramenter defines the sample and reference
14 A
measurement sequence.
15 Command _____ puts the analyser in measurement mode. "-
16 To print the spectrum use the command _____. :
During a validation run, the std value was 200 ppm and the
analyser reading was 300 ppm.If your old intercept value was
17 "+300
-200, what will be your new intercept value to coorect for the
difference between the std value and the analyser reading?
During a validation run, the std value was 200 ppm and the
analyser reading was 150 ppm.If your old intercept value was
18 "+300
-150, what will be your new intercept value to coorect for the
difference between the std value and the analyser reading?
19 The sample measurement duration is set to _____. 1 min
The normal sample flowrate adjusted for the analyser is _____
20 10
lph
If the reference LED is glowing on the MHA box, then the
21 Reference
measuring head is in _______ position.
PPU is a pulse processing unit for input signals from ____ &
22 MMU
A/D converters.
For communicating with analyser from a PC, the analyser
23 Line
should be put in ______ mode.
24 Which parameter is a gain control parameter? G
25 Which command is used to output th normalised intensities. +
The local display software of the analyser operates in 5
26 different modes. These are _______, View mode,Result ASCII mode
mode,Gain mode,Alarm mode.
The analog current( 4-20 ma)signal is generated by _____
27 PPU
card.
What is the thickness of the yellow protection window in the
28 1 micron
SCA?
The sample bypass flowrate should be maintained between
29 10 to 100
_____ lph
While doing any maintenance on the SCA, the Maintenance
30
switch on the PES should be place in Off position. 1
Before starting validation of the analyser, the sample cell
31 should be flushed first with IPA and then with the standard
solution. 1
Nitrogen purge through the sample cell should be stopped
32
while carrying out validation . 1
Viscosity
9 The OIW 101 analyser is suitable of pipe line sizes of 4" to 60". 1
The EPROMs also need to be replaced if the detector is
10 replaced. 1
To note the absolute maximum possible output that the
11 detector can generate, the antenna should be ____. Short cktd to gnd
To note the absolute minimum possible output that the
12 detector can generate, the antenna should be ____. Short cktd to gnd
13 The output of the detector is_____. Current
To check zero % oil indication, flow 100% water through the
14 analyser. 1
To check 100 % oil indication, flow 100% oil through the
15 analyser. 1
16 The detector's unit can be switched with that of a similar unit. 1
Which port should be adjusted during calibration as per
17 method 1 in the manual. R22
As per calibration method 1 in the manual, which terminals are
18 to be used to measure the output current? TP 6 & 11
What will be the instrument's % water reading on the display if
19 the 15 VDC to the detector has failed. 0%
What will be the instrument's % water reading on the display if
20 the antenna is shorted. 0%
What should be the resistance between the antenna jack and
21 the metal enclosure? 1 ohm
If the resistance between the antenna jack and the metal
enclosure is < 20 mega ohm, then it is possible that the
22 antenna is______. Open cktd
If there is inert material like sand , dirt etc in the sample ,then
23 the instrument will read it as _____. Water
The sample components with low dielectric constants will be
24 detected as______ OIl
Instrumentation &
30 What is the fullform of IC
Control
The water used by the analyser for rinsing the internal tubes is
31 1
tap water.
What is the height of the catalyst required to be filled in the
32 180 cm
combustion tube.
Conductivity detectors are also used in CO2 measurements in
33 1
TOC analysers.
Power supply to the analyser should be switched off
34 1
immediately after switching off the furnace.
The" Furnace Over Heat" error message appears when the
35 120
furnace temperature exceeds ____ deg C.
Option 2 Option 3 Option 4 Answers
Thermal
Chemiluminescence XRF Option 3
conductivity
Xenon ray
Both None Option 1
fluorescence
Yetrium Mollybdenum None Option 3
Oxygen Hydrogen Argon Option 4
0 Option 1
TCD FID NDIR Option 1
Platinum Berylleum Carbon Option 3
2 mm 0.5 mm 25 um Option 4
X ray tube MHA Leak detector Option 4
B # #A Option 4
#A 2+ None Option 3
B S Z Option 3
"+ ! ? Option 3
; " > Option 1
Option 2
0
Option 1
0
Option 2
0
Hagan
Beer lambert's
Newton's laws Poiseuille Option 3
law
equation
Atomic
Atomic weight None Option 1
number
Cpo Both None Option 1
0 Option 1
Non volatile Newtonian None Option 3
200 250 100 Option 4
Capillary outlet Both None Option 2
0 Option 2
30 ltrs 18 ltrs 100 ltrs
0 Option 1
18 ltrs 15 ltrs 10 ltrs Option 2
0 Option 1
Input O/P & I/P None Option 2
2 ul 4.8 ul 4 ul Option 3
8 2 6 Option 2
0 Option 1
Twice in a No
Every 4 months Option 2
month replacement.
15 100 20 Option 4
15 120 20 Option 3
SS316 KHP IPA Option 1
0 Option 2
0 Option 1
0 Option 1
0 Option 1
0 Option 2
0 Option 1
0 Option 1
110 VAC 24 VDC 5 VDC Option 3
3 4 1 Option 4
MS TS None Option 1
MS BS DC Option 4
UV/Persulphat
IR Combustion Option 3
e
Cl Br NaCl Option 1
Pt coated on
Ag Gold Option 4
alumina balls
Total Organic Total Oxygen Total Organic
Option 2
Carbon content Combustion.
IC-TC TC-IC TC/IC Option 3
UV IR Spectroscopy Option 1
Halogens N2 H2 Option 2
150 cc/min 200 cc/min 50 cc/min Option 2
150 cc/min 200 cc/min 50 cc/min Option 1
150 kpa 200 kpa 250 kpa Option 3
3 lpm 5 lpm 2 lpm Option 4
0 Option 2
0 Option 2
Sr no Questions Option 1
2 The range of panametrics moisture moisture probe is -110 deg c to +20 deg C
-100 deg c to +100 deg C -200 deg c to +200 deg C -50 deg c to +50 deg C Option 1