ISO IEC 17025 Accreditation Cert+Scope-GCC Accreditation
ISO IEC 17025 Accreditation Cert+Scope-GCC Accreditation
ISO IEC 17025 Accreditation Cert+Scope-GCC Accreditation
GAC
Calibration Laboratory
Accreditation No. ACL 0014
is accredited by the GCC Accreditation Center (GAC) in accordance with the recognized International Standard ISO/IEC 17025:2017, “General
requirements for the competence of testing and calibration laboratories”
Locations where calibration activities covered by the above Accreditation Standard are undertaken
1- Industrial Area 13, Near Rameez Hyper Market, Along E311 Road, Sharjah, UAE
Scope:
1. Calibration
1.25 Torque measuring devices
.02 Torque transducers
1.26 Testing machines
.01 Tension and universal machines in tension
.02 Compression and universal machines in compression
1.23 Force measuring devices
.05 Force gauges
1.20 Pressure and vacuum measuring devices
.01 Pressure gauges
.02 Vacuum gauges (bourdon tube)
1.03 Engineering metrology equipment
.01 Surface plates
.06 Bevel protractors
.13 Thread measuring accessories
.21 Micrometer heads
.22 External micrometers
.24 Depth micrometers
.25 Electronic indicators, dial gauges and test indicators
.26 Bore gauges
.27 Electronic and Vernier calipers
.28 Electronic and Vernier height and depth gauges
.29 Feeler gauges
Version: 1.4 Page 2 of 21
Date: 24th July 2019
Approved by: Atta Subhan
Accreditation Procedures
GAC
200 mΩ 0.04%
500 mΩ 0.02%
1Ω 0.02%
>1 Ω - 10 Ω 0.006%
Multiproduct
>10 Ω - 100 Ω 0.005% Calibrator
CI/01/M1 Based on
>100 Ω - 1MΩ 0.004% Standard P/S
Generation - Resistance EURAMET cg-15
>1 MΩ - 3.3 MΩ 0.007% Resistance(s)
>3.3 MΩ - 11 MΩ 0.02%
>11 MΩ - 33 MΩ 0.03%
>33 MΩ - 110 MΩ 0.06%
>110 MΩ - 330 MΩ 0.3%
>330 MΩ - 1 GΩ 1.7%
Multiproduct
Calibrator
Generation - Inductance 1 mH to 10 H 1% CI/01/M1 P/S
Standard Capacitance
Box
Measurement-Resistance 1 mΩ to 100 MΩ 300 nΩ - 230 ppm Master LCR Meter
CI/01/EC1
Measurement-Capacitance 1 pF to 1 F 20 ppm - 90 ppm P/S
Measurement- Inductance 10 nH to 100 kH 0.10%
Safety Testers
Earth Bond Resistance 36 mΩ to 1 Ω 5 mΩ to 11 mΩ
5Ω 29 mΩ Electrical Test
CI/01/SA1 Based on
equipment Calibrator P
10 Ω 58 mΩ Transmille 3200 Manual
100 Ω 580 mΩ
1000 Ω 5.8 Ω
100 mA 9 mA Electrical Test
Earth bond current @ 0.1Ώ CI/01/SA1 Based on
equipment Calibrator P
load @ 50 Hz 4 A - 25 A 0.5 A Transmille 3200 Manual
2.2 mA 40 μA Electrical Test
PAT Leakage current @ 240 CI/01/SA1 Based on
4.7 mA 80 μA equipment Calibrator P
V Transmille 3200 Manual
7.7 mA 140 μA
Electrical Test
CI/01/SA1 Based on
Load for PAT @ UAE Mains 0.13 kVA 6% equipment Calibrator P
Transmille 3200 Manual
0.2 Ω - 2 Ω 30 mΩ Electrical Test
CI/01/SA1 Based on equipment Calibrator
Continuity Resistance 2 Ω - 10 Ω 40 mΩ - 58 mΩ P
Transmille 3200 Manual
10 Ω - 20 Ω 58 mΩ - 90 mΩ
0.51 Ω 43 mΩ
1Ω 44 mΩ Electrical Test
CI/01/SA1 Based on
Loop impedance 5Ω 56 mΩ equipment Calibrator P
Transmille 3200 Manual
10 Ω 80 mΩ
99 Ω 590 mΩ
994 Ω 5.8 Ω
CI/05/CFG1 Based on
30 rpm to 60000 rpm 1 rpm Master Tachometer P/S
Rotational Speed-Measure SANAS TR-45-02
Note: the text in blue indicates the new scope OR update in the Edition of a method in this issue of the scope of accreditation.
Log of Suspended Scopes:
CMC Expressed as an Method Type of Instrument Permanent lab (P) Date Date
Measurand Measuring Range Expanded (standard/guide + or Material Suspended Reinstated
/ Client-site (S) *
Uncertainty (k = 2) ** internal procedure)
END
This conformity assessment body (CAB) is recorded as issuing GAC accredited certificates to organizations in the countries listed below. This list is current
at the time of issue of this schedule.
United Arab Emirates Bahrain Saudi Arabia Oman Qatar Kuwait Yemen