Industrial Hydraulic Pumps T7/T67/T6: Denison Vane Technology, Fixed Displacement
Industrial Hydraulic Pumps T7/T67/T6: Denison Vane Technology, Fixed Displacement
Industrial Hydraulic Pumps T7/T67/T6: Denison Vane Technology, Fixed Displacement
T7/T67/T6
Denison Vane Technology, fixed displacement
Catalogue HY29-0001/UK Hydraulic Pumps
Content
T7/T67/T6C Industrial, Denison Vane Pumps
2 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
Content T7/T67/T6C Industrial, Denison Vane Pumps
Notes ................................................................................................. 74
Warning ..............................................................................................75
3 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
Characteristics
T7/T67/T6C Industrial, Denison Vane Pumps
CHARACTERISTICS These vane pumps have been specially designed for high/low circuits.
The combination of different cartridges in double and triple pumps
allows low flow at high pressure (300 bar max.) and high flow at lower
pressure. This is a clever way to optimize your circuit design.
This pump feature will also allow a very fast pressure cycle change
with a very precise flow repeatability.
WIDE SPEED RANGE Industrial pumps : Min. : 600 RPM - Max. up to 3600 RPM
BETTER EFFICIENCY Increases productivity, reduces heating and reduces operation costs.
LOW NOISE LEVELS Increases operator safety and eases machines acceptances.
CARTRIDGE DESIGN Provides for drop-in assemblies. They permit easy conversion and
service.
A, B and D cartridges : bi-directional technology.
C and E cartridges : uni-directional technology.
WIDE RANGE OF ACCEPTABLE VISCOSITIES Viscosities from 860 to 10 cSt permit colder starts and hotter running.
The balanced design compensates for wear and temperature changes.
At high viscosity or cold temperature, the rotor to side plates gap is
well lubricated and improves mechanical efficiency.
FIRE RESISTANT FLUIDS AND BIODEGRADABLE Phosphate esters, organic esters, chlorinated hydrocarbons, water glycols,
FLUIDS rapeseed may be pumped at high pressures and with long service life
by these pumps.
GENERAL APPLICATIONS INSTRUCTIONS 1. Check speed range, pressure, temperature, fluid quality, fluid visco-
sity and pump rotation.
2. Check inlet conditions of the pump, if it can accept the application
requirements.
3. Check the type of shaft : if it will support the operating torque.
4. Check the coupling must be chosen to minimize pump shaft load
(weight, misalignment).
5. Filtration : must be adequate for the lowest contamination level.
6. Check the environment of the pump : as to avoid noise reflection,
pollution and shocks.
4 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
Single pumps : speeds, pressure ratings T7/T67/T6C Industrial, Denison Vane Pumps
For further information, or if the performance characteristics outlined here above do not meet your particular requirements, please consult
your local Parker office.
5 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
Single
pumps : speeds, pressure ratings T7/T67/T6C Industrial, Denison Vane Pumps
For further information, or if the performance characteristics outlined here above do not meet your particular requirements, please consult
your local Parker office.
6 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
Double & triple pumps : speeds, pressure ratings T7/T67/T6C Industrial, Denison Vane Pumps
7 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
Minimum
allowable inlet pressure (bar absolute) T7/T67/T6C Industrial, Denison Vane Pumps
8 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
Minimum
allowable inlet pressure T7/T67/T6C Industrial, Denison Vane Pumps
Inlet pressure is measured at inlet flange with petroleum base fluids at viscosity between 10 and 65 cSt. The difference between inlet pressure
at the pump flange and atmospheric pressure must not exceed 0,2 bar to prevent aeration.
Multiply absolute pressure by 1,25 for HF-3, HF-4 fluids.
by 1,35 for HF-5 fluid.
by 1,10 for ester or rapeseed base.
For double and triple pumps, prefer the cartridge requiring the highest absolute pressure.
9 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
Pump
selection T7/T67/T6C Industrial, Denison Vane Pumps
Routine : Example :
1000 Q 1000 x 42
1. First calculation Vi = n Vi = = 28 ml/rev.
1500
2. Choice Vi of pump immediately T7B B10, Vi = 31,8 cm3/rev.
greater (see tabulation)
4. Find qvs leakage function of pressure T7B (page 22) : qVs = 3 l/min at 250 bar,
qVs = f(p) on curve at 10 or 24 cSt 24 cSt
INTERMITTENT PRESSURE RATING T7 and T67 units may be operated intermittently at pressures higher than the recommended
continuous rating when the time weighted average of pressure is less than or equal to
the continuous duty pressure rating. This intermittent pressure rating calculation is only
valid when the other parameters : speed, fluid, viscosity and contamination level are
respected.
For total cycle time longer than 15 minutes, please consult your Parker representative.
300
200
0
(4 x 320) + (1 x 35) + (5 x 160) = 211,5 bar
0 5 10 10
Time (minutes)
211,5 bar is lower than 290 bar allowed as continuous pressure for T7B - B10 with
HF-0 fluid.
10 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
Description T7/T67/T6C Industrial, Denison Vane Pumps
Shaft end outlet port has Cap end outlet port has8-positions at
4-positions at 90° intervals 45° intervals relative to inlet on each
relative to inlet. Inlet double and triple pump.
Inlet Outlet
Front & rear sideplates are each
clamped axialy by the separate
discharge pressures.
Section B-B
Pin cavity is at a steady
pressure equal to that at A
B Discharge ramp
discharge port.
Section A-A where unloaded
Side feed holes supply discharge pressure to Working vane on minor arc seals
vane moves in.
pin cavities. discharge pressure from the suction
port.
APPLICATION ADVANTAGES • The high pressure capability up to 320 bar, in the small envelope,
reduces installation costs and provides extended life at reduced pressure.
• The high volumetric efficiency, reduces heat generation, and allows
speeds down to 600 RPM at full pressure.
• The high mechanical efficiency, typically better than 94%, reduces
energy consumption.
• The wide speed range (600 RPM at 3600 RPM), combined with
large size cartridge displacements will optimize operation for the
lowest noise level in the smallest envelope.
• The low speed (600 RPM), low pressure, high viscosity (860 cSt)
allows application in cold environment with a minimum energy
consumption and without risk of seizure.
• The low ripple pressure (± 2 bar) reduces piping noise and increases
lifetime of the other components in the circuit.
• The high resistance to particle contamination, thanks to the double
lip technology increasing the pump lifetime.
• The large variety of options (cam displacement, shaft, porting)
allows customized installation.
• Noise : Specially designed to optimize the low noise level cha-
racteristics.
• Cartridge concept : drops maintenance costs.
11 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
Start-up instructions & recommendations T7/T67/T6C Industrial, Denison Vane Pumps
GENERAL : All Parker vane pumps are individually tested to provide the best quality
& reliability. Modifications, conversions & repairs can only be done by
authorized dealers or OEM to avoid invalidation of the guarantee.
The pumps are to be used in the design limits indicated in all the sales
bulletins. Please contact Parker when tresspassing the catalogue limits.
Do not modify or work on the pump under pressure or when the electric
motor (or any drive) is on.
Qualified personnel is required to assemble and set-up hydraulic devices.
Always conform yourself to the valid regulations (safety, electrical, envi-
ronment...).
The following instructions are important to follow to obtain a good ser-
vice life time from the unit.
ROTATION & PORTS INDICATION The rotation and ports orientation are viewed from the shaft end.
CW stands for clockwise = right-hand rotation.
CCW stands for counter-clockwise = left-hand rotation.
START-UP CHECK-UP Check that the assembly of the power unit is correct :
The distance between the suction pipe & the return lines in the tank should
be at its maximum.
A bevel on both suction & return lines is recommended to increase the
surface and so lower the velocity. We suggest a 45° minimum angle.
Velocities : inlet 0,5 < x < 1,9 m/s (1,64 < x < 6,23 ft per sec.)
: return x < 6 m/s (x < 19,7 ft per sec.)
. : Always insure that all return and suction lines are under the
oil level to avoid forming aeration or vortex effect. This
should be done under the most critical situation (all cylin-
ders extended for example). Straight and short pipes are the
best.
Q (Lpm) Q (GPM)
V= = m/s V= = ft/s
6 x p x r2 (cm) 3.12 x p x r2 (in)
The size of the air filter should be 3 times greater than the max. instant
return flow (all cylinders in movement for example).
If the pump is in the tank, please choose the NOP option (no paint) and
use a short inlet pipe.
Parker does not recommend inlet strainers. If needed, a 100 mesh (149
microns) is the finest mesh recommended.
A coaxial drive is recommended. For any other type of drives, please
contact Parker.
Make sure that all protective plugs & covers have been removed.
Check the pump rotation versus the E-motor or engine rotation.
Start-up :
The tank has been filled up with a clean fluid in proper conditions.
We recommend to flush the system with an external pump prior to the
start-up.
It is important to bleed the air off the circuit & the pump itself.
The first valve on the circuit should be open to tank.
We recommend the use of air bleed off valves.
It is possible to bleed off the air by creating a leak in the P port of the
pump. Warning : this has to be done in a low pressure mode as it could
create a dangerous fluid leak. Make sure that the pressure cannot rise
(open center valve to tank, pressure relief valve unloaded ...).
12 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
Start-up instructions & recommendations T7/T67/T6C Industrial, Denison Vane Pumps
When oil free of air appears, tighten the connectors to the correct
torque.
The pump should prime within a few seconds. If not, please consult
our troubleshooting guide (document 1 - EN0721 - *).
If the pump is noisy, please troubleshoot the system.
Never operate the pump at top speed and pressure without checking
the completion of pump priming.
SHAFT & COUPLING DATA :
COUPLINGS AND FEMALE SPLINES • The mating female spline should be free to float and find its own
center. If both members are rigidly supported, they must be aligned
within 0,15 TIR (0.006” TIR) or less to reduce fretting. The angular
alignment of two splines axes must be less than ± 0,05 per 25,4 radius
(± 0.002” per 1” radius).
• The female spline must be made to conform to the Class 1 fit as des-
cribed in SAE-J498b (1971). This is described as a Flat Root Side Fit.
KEYED SHAFTS Parker supplies the T7 series keyed shaft pumps with high strength
heat-treated keys. Therefore, when installing or replacing these pumps,
the heat-treated keys must be used in order to ensure maximum life in
the application. If the key is replaced, it must be a heat-treated key
between 27 and 34 R.C. hardness. The corners of the keys must be
chamfered by 0,76 mm to 1,02 mm (0.03 to 0.04) at 45° to clear the
radii in the key way.
The alignment of keyed shafts must be within tolerances given for splined
shafts here above.
SHAFT LOADS These products are primarily designed for coaxial drives which do not
impose axial or side loading on the shaft. Contact Parker for specific
applications.
SPECIFIC POINTS :
MINIMUM INLET PRESSURE Please read the charts in the sales leaflets as the minimum requested
inlet pressure varies versus the displacement and the speed.
Never go under 0,8 bar Absolute (-0,2 bar relative)
11.6 PSI Absolute (-2.9 PSI G).
MAXIMUM INLET PRESSURE It is recommended to always have at least 1,5 bar (22 PSI) differen-
tial between inlet and outlet.
Standard shaft seals are limited to 0,7 bar (10 PSI G) but some allow
7 bar (100 PSI G). Please contact Parker for more information.
MINIMUM OUTLET PRESSURE It is recommended to always have at least 1,5 bar (22 PSI) differen-
tial between inlet and outlet.
VERTICAL MOUNT When assembled vertically, always be careful to prevent any air from
being trapped in the pump (behind the shaft seal for example).
FLUIDS :
DENISON CLASSIFICATION Type of fluids : For each type of fluids, Parker vane pumps will have
different pressures, speeds & temperature limits. Please refer to the
sales leaflets.
HF-0 = Anti-wear petroleum base.
HF-1 = Non anti-wear petroleum base.
HF-2 = Anti-wear petroleum base.
HF-3 = Water-in-oil invert emulsions.
HF-4 = Water glycol solutions.
HF-5 = Synthetic fluids.
13 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
Start-up
instructions & recommendations T7/T67/T6C Industrial, Denison Vane Pumps
Fluid motor speed rpm 1000 x flow rate (Lpm) x volumetric eff.
displacement (cm3/rev.)
Fluid motor torque N.m pressure (bar) x displacement (cm3/rev) x mech. eff.
20 p
14 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
General characteristics T7/T67/T6C Industrial, Denison Vane Pumps
15 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
General
characteristics T7/T67/T6C Industrial, Denison Vane Pumps
16 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
Notes T7/T67/T6C Industrial, Denison Vane Pumps
17 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7AS
- Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
P P P = Pressure
S = Suction
P
00 01 02 03
8 66
Pe = 0,9 bar abs
Internal leakage qVs [l/min]
1,2 1100
n = 1000 RPM
1 n = 1500 RPM [24 cSt] = =
900
Power loss Ps [kW]
F
0,8
Load F [N]
700 Fa
0,6 Shaft keyed N°1
500
0,4
0,2 300
0
100
0 60 120 180 240 300
600 1200 1800 2400 3000 3600
Pressure p [bar] Speed n [RPM]
* Cartridge designation is now in ml/rev. (example : B22 = 22,5 ml/rev.) Maximum permissible axial load Fa = 600 N
18 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7AS - Dimensions - Weight : 9,5 kg T7/T67/T6C Industrial, Denison Vane Pumps
138,5 44,4
Ø 95,3 7,4
6,4
KEY 4,775
4,724
(THREADED PORT
(THREADED PORT
CONNECTION)
CONNECTION)
68
63,5
65
60,5
Ø 11
25,4
-0.05
0
C.G.
Ø 47
Ø 82,55
110
1,5 x 45°
64
-0.025
21,14 MAX
0,8 x 45°
0
Ø 19,05
53 MOUNTING TORQUE : 110 Nm
106
19,1
1,5 x 45°
P S
47,6
52,4
SHAFT CODE 3
SAE B splined shaft
Class 1 - J498
16/32 d.p. - 13 teeth
30° pressure angle
flat root side fit PRESSURE Ø B SUCTION Ø A
19 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7ASW
- Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
8 73
Pe = 0,9 bar abs
7 24 cSt 71
Internal leakage qVs [l/min]
n = 1000 RPM
10 cSt
6 n = 1500 RPM
69
uν = 32 cSt
5 67 Lw = Lp + 8 db(A)
4 65
3 63
2 61
1 59
0 57
0 60 120 180 240 300 0 50 100 150 200 250 300
1,2 1100
n = 1000 RPM
1 n = 1500 RPM [24 cSt] = =
900
Power loss Ps [kW]
F
0,8
Fa
Load F [N]
0,4 500
0,2 300
0
0 60 120 180 240 300 100
600 1200 1800 2400 3000 3600
Pressure p [bar] Speed n [RPM]
* Cartridge designation is now in ml/rev. (example : B26 = 26 ml/rev.) Maximum permissible axial load Fa = 800 N
20 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7ASW - Dimensions - Weight : 11,3 kg T7/T67/T6C Industrial, Denison Vane Pumps
110 160,8 44
99,7 38,2
Ø 95,3
7,4
KEY 4,775 / 4,724
6,4
(THREADED PORT
(THREADED PORT
CONNECTION)
CONNECTION)
68
63,5
60,5
65
Ø 11
25,4
Ø 52,02
82,55
Ø 82,5
110
1,5 x 45°
74,6
21,12 MAXI
0,8 x 45°
-0.025
0
Ø 19,05
53
130,4
SHAFT CODE 1
(KEYED NO SAE)
19
24,5
1,5 x 45°
47,6
58,7
1,5 x 45°
21 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7B
/ T7BS - Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
8 70
Internal leakage qVs [l/min]
2 55
0 50
0 40 80 120 160 200 240 280 320 0 40 80 120 160 200 240 280 320
Pressure p [bar] Pressure p [bar]
Do not operate pump more than 5 seconds at any speed or viscosity
if internal leakage is higher than 50% of theoretical flow.
1,4 1400
n = 1000 RPM
1,2 1200 Shaft
n = 1500 RPM [24 cSt] = =
Power loss Ps [kW]
keyed
1 Fn°1
1000
Load F [N]
Fa
0,8
Shaft keyed N°1
800
0,6
600
0,4
0,2 400
0 200
0 40 80 120 160 200 240 280 320
600 1200 1800 2400 3000 3600
Pressure p [bar] Speed n [RPM]
Maximum permissible axial load Fa = 800 N
22 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7B/BS
- Dimensions - Weight : 23,0 kg T7/T67/T6C Industrial, Denison Vane Pumps
76,2
ØH
101,60
Ø 101,55
C.G.
Ø 51,3
24,94 MAXI
22,225
Ø 22,200
120,6 1,5 x 45°
1,3 x 45°
Shaft code 1
(KEYED SAE "B")
9,7
Mounting torque : 187 Nm T7BS SERIES
(FLANGE SAE "B")
40,7 10
45,6
7,9 35,8 C
7,9
24,5 17,9
24,5 KEY 8 x 7
40,0
1,5 x 45°
1,5 x 45°
Ø 99, 967
100,000
S P
70,0
D
35,0
28,22 MAXI
25,007
Ø 24,993
1,5 x 45°
23 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T6C
- Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
P = Pressure port
S S = Suction port
75
21 Pe = 0,9 bar abs
24 cSt
Internal leakage qVs [l/min]
nSérie
= 1000 RPM
18 10 cSt n1 = 1500 RPM
70
15
u
u = 32 cSt
Lw = Lp + 8 db (A)
12
65
9
6 60
3
0 55
0 35 70 105 140 175 210 245 280 0 40 80 120 160 200 240
Pressure p [bar] Pressure p [bar]
Do not operate pump more than 5 seconds at any speed or viscosity
if internal leakage is higher than 50% of theoretical flow.
3,5 1400
n = 1000 RPM
3 n = 1500 RPM [24 cSt] 1200 = =
n = 2800 RPM
Shaft
Power loss Ps [kW]
2,5 Fkeyed
1000 n°1 Fa
Load F [N]
0,5
400
0 200
0 40 80 120 160 200 240 280 600 1000 1400 1800 2200 2600
Pressure p [bar] Speed n [RPM]
Maximum permissible axial load Fa = 800 N
24 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T6C
- Dimensions - Weight : 15,7 kg T7/T67/T6C Industrial, Denison Vane Pumps
76,2
101,60
Ø 101,55
C.G.
Ø 51,3
135,0
M8 16 DEEP
75,7
24,94 MAXI
22,225
Ø 22,200
1,5 x 45°
Ø 14,3
1,3 x 45°
Mounting torque : 159 Nm. SHAFT CODE 1
(Keyed SAE B)
24,53 MAXI
P
70,0
S
52,4
26,2
35,0
22,225
Ø 22,200
1,5 x 45°
SHAFT CODE 2
SHAFT CODE 3 (Keyed non SAE )
SHAFT CODE 4
SAE B INVOLUTE SPLINE DATA SAE BB INVOLUTE SPLINE DATA
CLASS 1-FLAT ROOT SIDE FIT CLASS 1-FLAT ROOT SIDE FIT
J498b - PITCH 16/32 J498b - PITCH 16/32 SUCTION Ø 38,1 PRESSURE Ø 25,4
13 TEETH - 30° PRESSURE ANGLE 15 TEETH - 30° PRESSURE ANGLE
Shaft torque limits [ml/rev. x bar]
Shaft Vi x p max.
1 16340
2 14300
3 20600
4 21800
OPERATING CHARACTERISTICS - TYPICAL [24 cSt]
Pressure Vi Volumetric Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPM
Series
port displacement p = 0 bar p = 140 bar p = 240 bar p = 7 bar p = 140 bar p = 240 bar
B03 10,8 ml/rev 16,2 11,2 7,7 1,3 5,3 8,4
B05 17,2 ml/rev 25,8 20,8 17,3 1,4 7,5 12,2
B06 21,3 ml/rev 31,9 26,9 23,4 1,5 8,9 14,7
B08 26,4 ml/rev 39,6 34,6 31,1 1,6 10,7 17,7
B10 34,1 ml/rev 51,1 46,1 42,6 1,7 13,4 22,3
B12 37,1 ml/rev 55,6 50,6 47,1 1,7 14,4 24,1
T6C B14 46,0 ml/rev 69,0 64,0 60,5 1,9 17,6 29,5
B17 58,3 ml/rev 87,4 82,4 78,9 2,1 21,9 36,9
B20 63,8 ml/rev 95,7 90,7 87,2 2,2 23,8 40,2
B22 70,3 ml/rev 105,4 100,4 96,9 2,3 26,1 44,1
B25 79,3 ml/rev 118,9 113,9 110,4 2,5 29,2 49,5
B28 88,8 ml/rev 133,2 128,2 125,81) 2,8 32,7 48,51)
B31 100,0 ml/rev 150,0 145,0 142,61) 2,8 36,5 54,41)
1)
B28 - B31 = 210 bar max. int.
2)
Port connection can be supplied with metric threads (Please contact Parker).
25 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7D
/ T7DS - Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
P = Pressure port
S S = Suction port
30 75
Pe = 0,9 bar abs
27 24 cSt
Internal leakage qVs [l/min]
Série
n = 1000 RPM
24 10 cSt
70 1n = 1500 RPM
21
u = 32 cSt
υ
Lw = Lp + 8 db (A)
18
15 65
12
9
60
6
3
0 55
0 50 100 150 200 250 300 0 40 80 120 160 200 240 280
3,5 1800
n = 1000 RPM
3 1600 Shaft keyed
n = 1500 RPM [24 cSt] = =
n°1
Power loss Ps [kW]
1400 F
2,5
1200 Fa
Load F [N]
2
1000 Shaft keyed N°1
1,5
800
1 600
0,5 400
0 200
0 50 100 150 200 250 300 600 900 1200 1500 1800 2100 2400
26 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7D/DS - Dimensions - Weight : 26,0 kg T7/T67/T6C Industrial, Denison Vane Pumps
T7DS
184,9 83,6
212,4 87,4 38,1 12,7
C 7,9
6,35 MA XI 49,3
D KE Y 7,94
7,89
82, 6
M10 x 20 DEEP
156, 7
127, 00
Ø 126, 95
Ø 64, 3
C.G.
Ø E
76,2
35, 3 MAXI
31, 75
Ø 31, 70
2,3 x 45°
SHAFT CODE 1
87,4 (Key ed SAE C)
147,4 MOUNTING TORQUE : 187 Nm 9,0
77,7 (*) 73,2 Ø A x 23,9 DEEP Ø B x 22 ,3 DEEP 6,35 MAXI
15,7 50,0
7,9 7,9
48,0 38,1 30,2
KEY 7,94 42,9
7 ,89 15,1
21,45 KE Y 10 x 8
35,3 M AXI
2,3 x 45°
M10 x 20 DEEP
31, 75
Ø 31, 70
38, 9
29, 35
125, 000
Ø 124, 937
Ø 64, 3
S P
77, 8
58, 7
2,3 x 45°
35, 3 MA XI
32, 018
Ø 32, 002
SHAFT CODE 4 SHAFT CODE 2 2,3 x 45°
S A E C S pc (* ) I N VOL U T E S P LI N E D ATA (Keyed non SAE)
C L A SS 1 -FL AT ROOT SIDE FI T
J498 b - PI T C H 12/24
14 T EET H - 30 ° P R ES S UR E A N G L E SHAFT CODE 5
55,2 (ISO 3019/2- G 32 M)
SU CTION Ø 50,8 * PRESSURE Ø 31,8
7,9 7,9
38,0
2,3 x 45°
T7D
27 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7E
/ T7ES - Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
33
24 cSt Pe = 0,9 bar abs
30
Internal leakage qVs [l/min]
n = 1000 RPM
Série
27 10 cSt
n = 1500 RPM
75 1u
24 υ = 32 cSt
21 Lw = Lp + 8 db (A)
18
70
15
12
9 65
6
3
0 60
0 30 60 90 120 150 180 210 240 0 40 80 120 160 200 240
Pressure p [bar] Pressure p [bar]
Do not operate pump more than 5 seconds at any speed or viscosity
if internal leakage is higher than 50% of theoretical flow.
F
4 2400 Fa
Load F [N]
1600
2
1200
1
800
0 400
0 30 60 90 120 150 180 210 240 600 1000 1400 1800 2200
Pressure p [bar] Speed n [RPM]
Maximum permissible axial load Fa = 2000 N
28 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7E/ES - Dimensions - Weight : 43,3 kg T7/T67/T6C Industrial, Denison Vane Pumps
MOUNTING TORQUE 187 Nm
213,0 225,3 90,9
T7ES
K 110,0 52,3 W
K/2 7,9 50,8
Ø 147.60 6,35 MAXI
KEY 9,52
9,47
M10 x 20 DEEP
98,6
Ød
42,36 MAXI
38,10
Ø 38,05
187,5
C.G.
Ø 76,2
ØS
2,3 x 45°
101,8
SHAFT CODE 1
e x 45°
( Keyed SAE C-C )
5/8”-11 UNC x 24 DEEP - 4 HOLES 1/2”- 13 UNC x 23,4 DEEP - 4 HOLES 17,5 90,0
M16 x 24 DEEP (METRIC VERSION) M12 x 23,4 DEEP (METRIC VERSION) 10,0
W
61,9
T7E
62,2 61,9 35,7
31,0 17,8
7,9 50,0
31,5 38,1 KEY 10 x 8
KEY 7.94
7.89
2,3 x 45° M10 x 20 DEEP
53,2
34,9
35,27 MAX
41,3 MAXI
31,75
Ø 31,70
38,018
Ø 38,002
S P
106,4
Ø S
69,8
2,3 x 45°
2,3 x 45°
e x 45°
SHAFT CODE 4 SHAFT CODE 2
SAE CC INVOLUTE SPLINE DATA ( Keyed no SAE ) SHAFT CODE 5
CLASS 1-FLAT ROOT SIDE FIT ( Keyed ISO/R775 - G38M)
J498b - PITCH 12/24 SUCTION Ø 75,00 * PRESSURE Ø 38,10
17 TEETH - 30° PRESSURE ANGLE
55,9
7,9
29 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7BB
/ T7BBS - Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
8 70
Internal leakage qVs [l/min]
4
P1-P2
3
60
2
0 55
0 40 80 120 160 200 240 280 320 0 40 80 120 160 200 240 280 320
Pressure p [bar] Pressure p [bar]
Do not operate pump more than 5 seconds at any speed or viscosity Double pump noise level is given with both stages discharging at the
if internal leakage is higher than 50% of theoretical flow. pressure value indicated on the curve.
Total leakage is the sum of each section loss under its respective
operating conditions.
POWER LOSS HYDROMECHANICAL (TYPICAL) PERMISSIBLE RADIAL LOAD
2,5 1400
n = 1000 RPM
P1-P2
n = 1500 RPM [24 cSt] 1200 =Shaft
=
2
Power loss Ps [kW]
1,5 Fa
Shaft keyed N°1
P1-P2 800
1
600
P1-P2
0,5
400
0 200
0 50 100 150 200 250 300 600 1000 1400 1800 2200 2600
Pressure p [bar] Speed n [RPM]
Total hydromechanical power loss is the sum of each section loss
under its respective operating conditions. Maximum permissible axial load Fa = 800 N
30 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7BB/BBS
- Dimensions - Weight : 32,6 kg T7/T67/T6C Industrial, Denison Vane Pumps
98,6
262,4
101,6 38,1
58,2
T7BBS
KEY 6,35 7,9 (FLANGE SAE "B ")
40,7 71,4 6,30 6,4 MAXI 31,7
7,9 7,9
38,1 KEY 4,762
24,5 4,712
1,5 x 45° M8 x 16 DEEP
84,1
76,2
74,7
101,60
Ø 101,55
C.G.
Ø 51,3
28,22 MAXI
1,5 x 45°
25,40
Ø 25,37
24,53 MAXI
22,225
Ø 22,200
1,5 x 45°
74,0
116,1
M
M M
100,000
Ø 99,967
P2 P1
174,5
S
47,6
D
F
88,9
44,5
28,2 MAXI
25,007
Ø 24,993
1,5 x 45°
G
PRESSURE Ø 19
2,0 x 45° SHAFT CODE 5
(KEYED ISO R775)
31 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T6CC
- Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
Type of shaft Severe duty shaft (T6CCW only) Always select the largest cartridge in the front place.
1 = keyed (non SAE) 2 = keyed (SAE BB)
3 = splined (SAE BB) 15 teeth Seal class
5 = splined (SAE B) 13 teeth 1 = S1 BUNA N - 0,7 bar max. (for mineral oil)
4 = S4 EPDM - 7 bar max. (for fire resistant fluids)
Direction of rotation (shaft end view) 5 = S5 VITON® - 7 bar max. (for mineral oil and fire
R = Clockwise resistant fluids)
L = Counter-clockwise
Design letter
Porting combination (see page 72)
00 = standard
75
21
Pe = 0,9 bar abs
Internal leakage qVs [l/min]
24 cSt
18 10 cSt
Série1
n = 1000 RPM
n = 1500 RPM
Série2
70
15
P1-P2 u
υ = 32 cSt
Lw = Lp + 8 db (A)
12
65
9 P1-P2
6
60
3
0 55
0 35 70 105 140 175 210 245 280 0 40 80 120 160 200 240
4 1400
n = 1000 RPM
n = 1500 RPM [24 cSt] 1200 = =
n = 2800 RPM Shaft
Power loss Ps [kW]
3 P1-P2 F n°1
keyed
1000 Fa
Load F [N]
0 200
0 40 80 120 160 200 240 280 600 1000 1400 1800 2200 2600
Pressure p [bar] Speed n [RPM]
Total hydromechanical power loss is the sum of each section loss
under its respective operating conditions. Maximum permissible axial load Fa = 800 N
32 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T6CC
- Dimensions - Weight : 26,0 kg T7/T67/T6C Industrial, Denison Vane Pumps
265,6 71,4
88,2 101,6 38,1
174,5
9,7 38,1
146,0
7,9
73,0
6,4 MAXI
KEY 6,35
6,30
84,1
76,2
M8 x 16 DEEP
101,60
Ø 101,55
Ø 51,3
C.G.
Ø 14,3
28,2 MAXI
126,0
25,40
Ø 25,37
73,2
1,5 x 45°
52,4
P2 S P1
A
26,2
F
1,5 x 45°
22,225
Ø 22,200
24,5 MAXI
SHAFT CODE 3 SHAFT CODE 5
SAE BB INVOLUTE SPLINE DATA SAE B INVOLUTE SPLINE DATA SHAFT CODE 1
CLASS 1-FLAT ROOT SIDE FIT CLASS 1-FLAT ROOT SIDE FIT ( Keyed
o non SAE )
J498b - PITCH 16/32 J498b - PITCH 16/32
15 TEETH - 30° PRESSURE ANGLE 13 TEETH - 30° PRESSURE ANGLE
PRESSURE Ø C SUCTION Ø H PRESSURE Ø 25,4
Alternate ports
S = 3" S = 2.1/2"2)
Code 00 01 1)
0M W0 1)
10 11 1)
1M W11)
A 52,4 47,7 52,4 47,7 52,4 47,7 52,4 47,7
B 26,2 22,4 26,2 22,4 26,2 22,4 26,2 22,4
ØC 25,4 19,0 25,4 19,0 25,4 19,0 25,4 19,0
D 74,7 76,2 74,7 76,2 74,7 76,2 74,7 76,2 Shaft torque limits [ml/rev. x bar]
E 3/8"-16 UNC x 19 deep M10 x 19 deep 3/8"-16 UNC x 19 deep M10 x 19 deep Shaft Vi x p max.
F 106,4 88,9 1 14300
G 61,9 50,9 2 21420
ØH 76,2 63,5 3 32670
K 5/8"-11UNC x 28,4 deep M16 x 28,4 deep 1/2"-13 UNC x 23,9 deep M12 x 23,9 deep 5 20600
1)
Max. cam B14 2)
P1 + P2 = 126 ml/rev. max.
OPERATING CHARACTERISTICS - TYPICAL [24 cSt]
Pressure Flow qVe [l/min] & n = 1500 RPM
Vi Volumetric Input power P [kW] & n = 1500 RPM
Series
port displacement
p = 0 bar p = 140 bar p = 240 bar p = 7 bar p = 140 bar p = 240 bar
B03 10,8 ml/rev 16,2 11,2 7,7 1,3 5,3 8,4
B05 17,2 ml/rev 25,8 20,8 17,3 1,4 7,5 12,2
B06 21,3 ml/rev 31,9 26,9 23,4 1,5 8,9 14,7
B08 26,4 ml/rev 39,6 34,6 31,1 1,6 10,7 17,7
P1 B10 34,1 ml/rev 51,1 46,1 42,6 1,7 13,4 22,3
B12 37,1 ml/rev 55,6 50,6 47,1 1,7 14,4 24,1
& B14 46,0 ml/rev 69,0 64,0 60,5 1,9 17,6 29,5
B17 58,3 ml/rev 87,4 82,4 78,9 2,1 21,9 36,9
P2 B20 63,8 ml/rev 95,7 90,7 87,2 2,2 23,8 40,2
B22 70,3 ml/rev 105,4 100,4 96,9 2,3 26,1 44,1
B25 79,3 ml/rev 118,9 113,9 110,4 2,5 29,2 49,5
B28 88,8 ml/rev 133,2 128,2 125,81) 2,8 32,7 48,51)
B31 100,0 ml/rev 150,0 145,0 142,61) 2,8 36,5 54,41)
1) B28 - B31 = 210 bar max. int. 2) Port connection can be supplied with metric threads, please contact Parker.
33 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T67CB
- Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
75
20 24 cSt Pe = 0,9 bar abs
nSérie
Internal leakage qVs [l/min]
18 = 1000 RPM
10 cSt
70 n1 = 1500 RPM
16 P1 υu = 32 cSt
14 Lw = Lp + 8 db (A)
12
65
10 P1
8 P2
6
P2 60
4
2
0 55
0 50 100 150 200 250 300 0 40 80 120 160 200 240
1 P1 1000 Fa
Load F [N]
0
Shaft keyed N°1
0 40 80 120 160 200 240 280
800
3,5
3 n = 1000 RPM
2,5 n = 1500 RPM [24 cSt] 600
P2
2 n = 2800 RPM
1,5 400
P2
1
0,5 P2 200
0
600 1000 1400 1800 2200 2600
0 50 100 150 200 250 300
Pressure p [bar] Speed n [RPM]
Total hydromechanical power loss is the sum of each section loss
under its respective operaring conditions. Maximum permissible axial load Fa = 800 N
34 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T67CB - Dimensions - Weight : 26,0 kg T7/T67/T6C Industrial, Denison Vane Pumps
174,5 265,6 71,4
146,0
88,2 101,6 38,1 9,7
73,0 7,9
6,4 MAXI 38,1
KEY 6,35
6,30
84,1
M8 x 16 DEEP
76,2
76,2
101,60
Ø 101,55
Ø 51,3
C.G.
Ø 14,3
28,22 MAXI
126,0
25,40
Ø 25,37
73,2
1,5 x 45°
T67CBW
MOUNTING TORQUE 159 Nm 1,5 x 45° SHAFT CODE 2
MOUNTING TORQUE : 61 Nm
(Keyed SAE B-B)
1/2-13 UNC x 23,9 DEEP - 4 HOLES
(M12 x 30,0 DEEP - METRIC VERSION) 12,7
52,4
P2 S P1
47,7
, 9
88
26,2
24,53 MAX
22,225
Ø 22,200
1,5 x 45°
35 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7DB
/ T7DBS - Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
22 75
Internal leakage qVs [l/min]
1600 F
1 P1
0 Fa
Load F [N]
1400
0 30 60 90 120 150 180 210 240 Shaft keyed N°1
1200
3,5
3 n = 1000 RPM
n = 1500 RPM [24 cSt]
1000
2,5
2 n = 2500 RPM P2 800
1,5
1 P2
600
0,5 P2
0 400
0 50 100 150 200 250 300 600 900 1200 1500 1800 2100 2400
Pressure p [bar] Speed n [RPM]
Total hydromechanical power loss is the sum of each section loss
under its respective operating conditions. Maximum permissible axial load Fa = 1200 N
36 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7DB/DBS - Dimensions - Weight : 38,6 kg T7/T67/T6C Industrial, Denison Vane Pumps
286,00 83,60
212,40
109,50 114,30 38,10 W
K 6,35 MAXI 49,30
K/2 7,90 KEY 7,94
P2 S P1 7,89
88,90
82,60
M10 x 20 DEEP
74,70
DIA d
Ø 64,30
C.G.
ØS
129,5
35,27 MAXI
31,75
Ø 31,70
74,05
2,30 x 45°
*
87,9 30,2
55,2 77,7
7,9
7,9 A 62,0
50,0 7,9
KEY 10 x 8 38,1 KEY 7,94
38,0 7,89
48,02
2,3 x 45°
2,3 °x 45
106,4
58,7
P2 S P1
B
35,27 MAXI
M10 x 20 DEEP
35,0 MAXI
32,018
Ø 32,002
31,75
Ø 31,70
2,3 x 45°
2,3 x 45°
PRESSURE Ø C
SHAFT CODE 5 SHAFT CODE 3 SHAFT CODE 4 PRESSURE Ø 31,8
( Keyed ISO/R775 - G32M ) SAE C INVOLUTE SPLINE DATA SAE C* Spc INVOLUTE SPLINE DATA
SHAFT CODE 2
SUCTION Ø 76 ( Keyed non SAE )
CLASS 1-FLAT ROOT SIDE FIT CLASS 1-FLAT ROOT SIDE FIT
J498b - PITCH 12/24 J498b - PITCH 12/24
14 TEETH - 30° PRESSURE ANGLE 14 TEETH - 30° PRESSURE ANGLE
Alternate mounting flange Alternate connect. variables Shaft torque limits [ml/rev. x bar]
00 & M0 01 & M1
Dia S A 26,20 22,20 Shaft Vi x p max. Shaft Vi x p max.
e x 45° W K Dia d 1 43240 4 61200
Max. Min. B 52,35 47,6
C 25,00 19,0 2 34590 5 42500
T7DB 125,000 124,937 2,0 9,5 180,0 18,0
T7DBS 127,000 126,950 1,3 12,7 181,0 17,5 3 61200
37 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T67DC
- Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
22 80
20 24 cSt Pe = 0,9 bar abs
nSérie
Internal leakage qVs [l/min]
18 P1 = 1000 RPM
10 cSt
P2
75 n1 = 1500 RPM
16 u
υ = 32 cSt
14 Lw = Lp + 8 db (A)
12
P1 70
10
8 P2
6
65
4
2
0 60
0 35 70 105 140 175 210 245 280 0 40 80 120 160 200 240
Pressure p [bar] Pressure p [bar]
Do not operate pump more than 5 seconds at any speed or viscosity Double pump noise level is given with both stages section dischar-
if internal leakage is higher than 50% of theoretical flow. ging at the pressure value indicated on the curve.
Total leakage is the sum of each section loss under its respective
operating conditions.
POWER LOSS HYDROMECHANICAL (TYPICAL) PERMISSIBLE RADIAL LOAD
6
n = 1000 RPM 2000
5 n = 1500 RPM [24 cSt] P1
4 n = 2500 RPM 1800 Shaft
3 P1 =keyed
=
1600
Power loss Ps [kW]
2 F
1 P1 1400 Fa
Load F [N]
0
Shaft keyed N°1
0 30 60 90 120 150 180 210 240 1200
4
n = 1000 RPM 1000
3 n = 1500 RPM [24 cSt]
n = 2500 RPM P2 800
2
P2
1 P2
600
0 400
0 40 80 120 160 200 240 280 600 900 1200 1500 1800 2100 2400
Pressure p [bar] Speed n [RPM]
Total hydromechanical power loss is the sum of each section loss
under its respective operating conditions. Maximum permissible axial load Fa = 1200 N
38 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T67DC - Dimensions - Weight : 38,6 kg T7/T67/T6C Industrial, Denison Vane Pumps
286,00 83,60
212,40 109,50 114,30 38,10 12,66
181,00 7,90
90,50 6,35 MAXI 49,30
KEY 7,94
7,89
88,90
82,60
M10 x 20 DEEP
74,70
127,00
Ø 126,95
Ø 64,30
C.G.
128,3
Ø 17,50
35,27 MAXI
74,05
31,75
Ø 31,70
2,30 x 45°
1,30 x 45°
7,90
83,40
60,00
55,20
7,90 *
7,90
77,70
38,10
2,30 x 45° KEY 7,94
38,00 48,00 7,89
KEY 7,94
7,89 2,30 x 45° 2,30 x 45°
29,35
106,40
P2 S P1
58,70
53,20
35,27 MAXI
31,75
Ø 31,70
M8 16 DEEP
38,42 MAXI
34,900
Ø 34,875
-
2,30 x 45°
39 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7DD
/ T7DDS - Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
22 80
20 24 cSt Pe = 0,9 bar abs
Internal leakage qVs [l/min]
18 nSérie
= 1000 RPM
10 cSt
75 n1 = 1500 RPM
16 P1-P2 u
υ = 32 cSt
14 Lw = Lp + 8 db (A)
12
70
10 P1-P2
8
6 65
4
2
0 60
0 30 60 90 120 150 180 210 240 0 40 80 120 160 200 240
Pressure p [bar] Pressure p [bar]
Do not operate pump more than 5 seconds at any speed or viscosity Double pump noise level is given with both stages discharging at the
if internal leakage is higher than 50% of theoretical flow. pressure value indicated on the curve.
Total leakage is the sum of each section loss under its respective
operating conditions.
POWER LOSS HYDROMECHANICAL (TYPICAL) PERMISSIBLE RADIAL LOAD
6 2000
n = 1000 RPM
1800
5 n = 1500 RPM [24 cSt] = Shaft
=
keyed
n = 2500 RPM P1-P2 1600 F
Power loss Ps [kW]
4 Fa
1400
Load F [N]
P1-P2 1000
2
800
1 P1-P2 600
0 400
0 30 60 90 120 150 180 210 240 600 900 1200 1500 1800 2100 2400
40 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7DD/DDS - Dimensions - Weight : 56 kg T7/T67/T6C Industrial, Denison Vane Pumps
347,7 84,0
134,2 148,3 38,3 w
7,9
6,4 MAXI
S
P2 P1 49,3
Key 7,94
7,89
Ø
d2
114,9
101,6
101,6
Ø d1
Ø 64,3
C.G.
K2
ØS
M10 x 20 DEEP
170,9
2,3 x 45°
91,3
35,27 MAXI
31,75
Ø 31,70
e x 45°
K2 19,0
MOUNTING TORQUE : 190 Nm MOUNTING TORQUE : 190 Nm
K1
213,0 SHAFT CODE 1
Keyed SAE C
7/16-14UNC x 22,3 DEEP
5/8-11UNC x 30 DEEP M12 x 22,3 DEEP-METRIC VERSION
M16 x 30 DEEP-METRIC VERSION 56,0
7,9
7/16-14UNC x 24 DEEP 6,4 MAXI
M12 x 24 DEEP-ME
TRIC VERSION 30,2 77,8
91,0 30,2
7,9 KEY 9,52
50,8 9,47 38,0
2,3 x 45°
2,3 x 45°
58,7
P2 S P1
182,0
162,2
58,7
130,2
M10 x 20 DEEP
42,36 MAXI
SHAFT CODE 3
38,10
Ø 38,05
46,0
68,0 PRESSURE Ø 29,5 SUCTION Ø 101,6 PRESSURE Ø 31,8
7,9
10,0
24,5
50,0
KEY 10 x 8
1,5 x 45°
M10 x 20 DEEP
35,00 MAXI
32,018
Ø 32,002
SHAFT CODE 4
SAE BB INVOLUTE SPLINE DATA
CLASS 1-FLAT ROOT SIDE FIT
SHAFT CODE 5 J498b - PITCH 16/32
Keyed ISO 3019/2 -G32M 15 TEETH - 30° PRESSURE ANGLE
41 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7EB
/ T7EBS - Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
33 80
30 24 cSt Pe = 0,9 bar abs
Internal leakage qVs [l/min]
nSérie
= 1000 RPM
27 10 cSt
n1 = 1500 RPM
75 u = 32 cSt
24 P1 υ
21 Lw = Lp + 8 db (A)
18
70
15 P1
12
9 P2 65
6
3
P2
0 60
0 50 100 150 200 250 300 0 40 80 120 160 200 240
Pressure p [bar] Pressure p [bar]
Do not operate pump more than 5 seconds at any speed or viscosity Double pump noise level is given with both stages discharging at the
if internal leakage is higher than 50% of theoretical flow. pressure value indicated on the curve.
Total leakage is the sum of each section loss under its respective
operating conditions.
POWER LOSS HYDROMECHANICAL (TYPICAL) PERMISSIBLE RADIAL LOAD
7
6 n = 1000 RPM
n = 1500 RPM [24 cSt]
2000
P1
5 n = 2200 RPM
4 P1 1800 = Shaft
=
3
2 1600 keyed
F
Power loss Ps [kW]
P1
1
Fa
0 1400
Load F [N]
42 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7EB/EBS - Dimensions - Weight : 55,0 kg T7/T67/T6C Industrial, Denison Vane Pumps
213,0 331,6 90,9
K 136,7 118,5 52,3 W T7EBS
K/2 7,9
6,4 MAX 50,8
KEY 9,52
55,9 9,47
7,9
38,1
M10 x 20 DEEP
102,4
98,4
2,3 x 45°
74,7
Ød
42,4 MAX
Ø 76,2
C.G.
ØS
2,3 x 45°
38,100
Ø 38,075
76,2
88,9
149,1
60,3
P1
47,6
ØS
P2
69,8
120,6
31,75
Ø 31,70
35,3 MAX
41,3 M AX
38,018
Ø 38,002
2,3 x 45°
2,3 x 45°
e x 45°
SHAFT CODE 4 SHAFT CODE 2
SAE *CC INVOLUTE SPLINE DATA (Keyed no SAE ) SHAFT CODE 5
CLASS 1-FLAT ROOT SIDE FIT PRESSURE Ø 19,00 SUCTION Ø 88,90 PRESSURE Ø 38,10 (Keyed ISO/R775 - G38M)
J498b - PITCH 12/24
17 TEETH - 30° PRESSURE ANGLE
Alternate mounting flange Alternate connect. variables Shaft torque limits [ml/rev. x bar]
01 M1
Dia S A 1/2" - 13 UNC M12 Shaft Vi x p max. Shaft Vi x p max.
e x 45° W K Dia d B 5/8" - 11 UNC M16 1 68500 4 68500
Max. Min.
C 3/8" - 16 UNC M10 2 34590 5 68500
T7EB 125,000 124,937 2,0 9,5 180,0 18,0
T7EBS 127,000 126,950 1,3 12,7 181,0 17,5 3 61200
43 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T67EC
- Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
33
24 cSt Pe = 0,9 bar abs
30
nSérie
= 1000 RPM
Internal leakage qVs [l/min]
10 cSt P1
27 n1 = 1500 RPM
24
75 u
υ = 32 cSt
Lw = Lp + 8 db (A)
21
P2
18
70
15
12 P1
P2
9 65
6
3
0 60
0 40 80 120 160 200 240 280 0 40 80 120 160 200 240
Pressure p [bar] Pressure p [bar]
Do not operate pump more than 5 seconds at any speed or viscosity Double pump noise level is given with both stages discharging at the
if internal leakage is higher than 50% of theoretical flow. pressure value indicated on the curve.
Total leakage is the sum of each section loss under its respective
operating conditions.
POWER LOSS HYDROMECHANICAL (TYPICAL) PERMISSIBLE RADIAL LOAD
7
6 n = 1000 RPM 2000
n = 1500 RPM [24 cSt]
5 P1
n = 2200 RPM
4 1800 Shaft
P1 = =
3
1600 keyed
F
Power loss Ps [kW]
2
P1
1
1400 Fa
Load F [N]
0
Shaft keyed N°1
0 30 60 90 120 150 180 210 240
1200
4
n = 1000 RPM
n = 1500 RPM [24 cSt] 1000
3 n = 2200 RPM
P2
800
2 P2
1 P2 600
0 400
0 40 80 120 160 200 240 280 600 1000 1400 1800 2200
Pressure p [bar] Speed n [RPM]
Total hydromechanical power loss is the sum of each section loss
under its respective operating conditions. Maximum permissible axial load Fa = 2000 N
44 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T67EC - Dimensions - Weight : 55,0 kg T7/T67/T6C Industrial, Denison Vane Pumps
213,0 331,6 90,9
181,0 136,7 118,5 52,3 12,7
7,9
90,5
6,4 MAXI KEY 9,52
50,8 9,47
M10 x 20 DEEP
102,4
98,4
74,7
Ø 17,5
127,00
Ø 126,95
C.G.
Ø 76,2
42,36 MAXI
38,100
Ø 38,075
76,2
149,1
88,9
2,3 x 45°
1,3 x 45°
MOUNTING TORQUE : 68 Nm SHAFT CODE 1
5/8-11 UNC x 29,5 DEEP - 4 HOLES 1/2-13 UNC x 23,4 DEEP - 4 HOLES 17,5 61,9
MOUNTING TORQUE : 187 Nm (M16 x 29,5 DEEP - METRIC VERSION) (M12 x 23,4 DEEP -METRIC VERSION ) ( Keyed SAE CC )
7,9
69,9 35,7
3/8-16 UNC x 19 DEEP - 4 HOLES
(M10 x 19 DEEP - METRIC VERSION) 34,9 17,8
55,9 A
7,9 62,2
7,9 38,1
38,1
31,5
KEY 7,94
7,89
2,3 x 45° 2,3 x 45°
P2 S P1
B
35,27 MAXI
Ø 31,70
31,75
2,3 x 45°
45 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7ED
/ T7EDS - Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
33
Pe = 0,9 bar abs
30 24 cSt
nSérie
= 1000 RPM
Internal leakage qVs [l/min]
3 3000 keyed
F
Power loss Ps [kW]
2
P1 Fa
1 2600
Load F [N]
46 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7ED/EDS - Dimensions - Weight : 66,0 kg T7/T67/T6C Industrial, Denison Vane Pumps
102,4
101,6
98,4
M10 x 20 DEEP
Ø d
42,36 MAX
C.G.
Ø 76,2
38,10
Ø 38,05
ØS
161,0 2,3 x 45°
81,0
89,0
e x 45 °
SHAFT CODE 1
(Keyed SAE CC )
MOUNTING TORQUE : 187 Nm MOUNTING TORQUE : 187 Nm
A x 23,4 DEEP - 4 HOLES 90,0
C x 24 DEEP - 4 HOLES B x 30 DEEP - 4 HOLES 10,0
62,2 55,9 61,9 30,2
15,1 38,9
77,8
17,8
35,7 W
T7ED
7,9 31,5 38,1
7,9 38,1 50,0
KEY 10 x 8
KEY 7,94
2,3 x 45° 2,3 x 45° 7,89 M10 x 20 DEEP
65,1
29,4
69,8
58,7
P2 S P1
ØS
130,2
35,27 MAX
31,75
Ø 31,70
41,3 MAXI
38,018
Ø 38,002
2,3 x 45°
2,3 x 45 °
e x 45°
SHAFT CODE 4 SHAFT CODE 3 SHAFT CODE 2
SAE CC INVOLUTE SPLINE DATA SAE C INVOLUTE SPLINE DATA (Keyed no SAE ) SHAFT CODE 5
CLASS 1-FLAT ROOT SIDE FIT CLASS 1-FLAT ROOT SIDE FIT PRESSURE Ø 31,80 SUCTION Ø 101,60 PRESSURE Ø 38,10
J498b - PITCH 12/24 J498b - PITCH 12/24 ( Keyed ISO/R 775 - G38M )
17 TEETH - 30° PRESSURE ANGLE 14 TEETH - 30° PRESSURE ANGLE
Alternate mounting flange Alternate connect. variables Shaft torque limits [ml/rev. x bar]
00 M0
Dia S A 1/2" - 13 UNC M12 Shaft Vi x p max. Shaft Vi x p max.
e x 45° W K Dia d 1 72300 4 68500
Max. Min. B 5/8" - 11 UNC M16
C 7/16" - 14 UNC M12 2 34590 5 68500
T7ED 125,000 124,937 2,0 9,5 180,0 18,0
T7EDS 127,000 126,950 1,3 12,7 181,0 17,5 3 61200
47 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7EE
/ T7EES - Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
85
33
Pe = 0,9 bar abs
30 24 cSt nSérie1
= 1000 RPM
Internal leakage qVs [l/min]
27 10 cSt nSérie2
= 1500 RPM
24
80 u = 32 cSt
υ
P1-P2 Lw = Lp + 8 db (A)
21
18
75
15 P1-P2
12
9 70
6
3
0 65
0 30 60 90 120 150 180 210 240 0 40 80 120 160 200 240
Pressure p [bar] Pressure p [bar]
Do not operate pump more than 5 seconds at any speed or viscosity Double pump noise level is given with both stages discharging at the
if internal leakage is higher than 50% of theoretical flow. pressure value indicated on the curve.
Total leakage is the sum of each section loss under its respective
operating conditions.
POWER LOSS HYDROMECHANICAL (TYPICAL) PERMISSIBLE RADIAL LOAD
7 3800
n = 1000 RPM 3400
6 n = 1500 RPM [24 cSt] = =
Shaft
n = 2200 RPM 3000 F
keyed
Power loss Ps [kW]
5 P1-P2
Fa
2600
Load F [N]
0 600
0 30 60 90 120 150 180 210 240 600 1000 1400 1800 2200
Pressure p [bar] Speed n [RPM]
Total hydromechanical power loss is the sum of each section loss
under its respective operating conditions. Maximum permissible axial load Fa = 2000 N
48 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7EE/EES - Dimensions - Weight : 95,0 kg T7/T67/T6C Industrial, Denison Vane Pumps
273,0
406,8
224,5 Ø 20.6
157,9 167,3 42,9 90,9
8,0
46
8 KEY 9,5 2
9,47
139,7
63,5
42,36 MAX
115
98,4
101,70 *
Ø 101,65
165,10
Ø 165,05
C.G.
273,0
224,5
170,0
86,6
38,100
Ø 38,075
104,5
118
M10 x 20 DEEP
1,5 x 45°
15,5
COUPLING ADAPTAT OR
SHAF T CODE 1
MOUNTING TORQUE : 300 N.m (KEYED SAE C-C)
22,0 9,0 MOUNTING TORQUE 88 N.m
M12 x 28 DEEP MOUNTING TORQUE 300 N.m
427,8 62,2
1/2-13 UNC x 23,4 DEEP - 4 HOLES 92,0
8,0 KEY 14 x 9
(M12 x 23,4 - METRIC VERSION) 1/2-13 UNC x 30 DEEP - 4 HOLES 10,0
(M12 x 30 - METRIC VERSION) 35,7
5/8-11 UNC x 30 DEEP - 4 HOLES
(M16 x 30 - METRIC VERSION) 77,8
35,7 63,0
48,5 MAX
250,000
Ø 249,928
45,000
Ø 44,975
Ø 146,0
S P1
173,3
222,7
P2
69,9
130,2
209
69,9
3,0 x 45°
SHAFT CODE 3
SAE CC SPLINED SHAFT
CLASS 1- J498b
12/24 D.P. - 17 TEETH T7EE
30° PRESSURE ANGLE
PRESSURE Ø 38,1 PRESSURE Ø 38,1
FLAT ROOT SIDE FIT
SUCTION Ø 101,6 1,5 x 45°
Ø 22,0
100,0
75,0
8,0
Code Coupling adaptor 8,0
0 Without coupling
SAE B - 13 teeth - Pitch 16/32
2 63,5
Major dia. (min) 22,225 - Minor dia. (min) 19,134 KEY 11,11
SAE BB - 15 teeth - Pitch 16/32 48,8 11,06
3
Major dia. (min.) 25,400 - Minor dia. (min.) 22,268 1/2-13 UNC
3,0 x 45° x 2 4 DEEP
2,3 x 45°
2 114600 SAE BB 32670
3 126800
SHAF T CODE 4 SHAF T CODE 5
4 126800 SAE D & E SPLINED SHAFT (KEYED SAE D & E)
CLASS 1- J498b
5 118340 8/16 D.P. - 13 TEETH
30° PRESSURE ANGLE
FLAT ROOT SIDE FIT
49 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7DBB
/ T7DBBS - Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
50 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7DBB / T7DBBS - Technical data T7/T67/T6C Industrial, Denison Vane Pumps
INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL) - T7DBB - B38 - B06 - B04
22 75
n1 = 1500 RPM
16 70 u
υ = 32 cSt
Lw = Lp + 8 db (A)
14
12
P1 65
10
8
P3-P3
6
60
4 P2-P3
0 55
0 50 100 150 200 250 300 0 40 80 120 160 200 240
Do not operate pump more than 5 seconds at any speed or viscosity Triple pump noise level is given with all stages discharging at the
if internal leakage is higher than 50% of theoretical flow. pressure value indicated on the curve.
Total leakage is the sum of each section loss under its respective
operating conditions.
6
n = 1000 RPM
5 n = 1500 RPM [24 cSt] P1
4 n = 2500 RPM 1800
3 =
Shaft
=
P1 1600 F
2 keyed
1 Fa
P1 1400
Shaft keyed N°1
Power loss Ps [kW]
0
0 30 60 90 120 150 180 210 240 1200
Load F [N]
3,5
n = 1000 RPM 1000
3
n = 1500 RPM [24 cSt]
2,5 n = 2500 RPM 800
2 P2-P3
600
1,5
P2-P3
1 400
0,5
P2-P3 200
0
600 900 1200 1500 1800 2100 2400
0 50 100 150 200 250 300
Total hydromechanical power loss is the sum of each section loss Maximum permissible axial load Fa = 1200 N
under its respective operating conditions.
51 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
421,8 56
213,1 99,5 122,4 138 38,1 w
7,9
6,35 MAXI
68,0
10,0 Ø
d2
KEY 10 x 8
127,0
Catalogue HY29-0001/UK
50,0
101,6
101,6
M10 x 20 DEEP
75,5
T7DBB/S-DCB/S-DCC/S
Ø d1
K2
ØS
Ø 64,3
38,018
5,4
41,0 MAXI
Ø38,002
95,6
74,0
2,3 x 45°
91,0
38
SHAFT CODE 5
Keyed ISO R775 - G38M e x 45°
SHAFT CODE 3
K2 SAE C INVOLUTE SPLINE DATA
MOUNTING TORQUE : 187 Nm CLASS 1-FLAT ROOT SIDE FIT
K1 MOUNTING TORQUE : 68 Nm J498b - PITCH 12/24
189,0
14 TEETH - 30° PRESSURE ANGLE
3/8 16 UNC x 19 DEEP - 4 HOLES 7/16 14 UNC x 22,3 DEEP - 4 HOLES
M10 x 19 DEEP - METRIC VERSION M12 x 22,3 DEEP - METRIC VERSION 19 84
52
31,5 63,5 KEY 9,52 KEY 6,35
9,47 6,30
0
M10 x 20 DEEP
Ø 31,75 -0.05
A
P3 P2 P1
38,100
S
52,4
130,2
58,7
42,3 MAXI
34,6 MAXI
Ø 38,075
2,3 x 45°
Hydraulic Pumps
Vierzon - France
Parker Hannifin
Shaft torque limits [ml/rev. x bar] Alternate mounting flange Alternate connect. variables
Shaft Vi x p max. P1 + P2 + P3 Shaft Vi x p max. P1 + P2 + P3 Dia S 00 & M0 01 & M1
Series e x 45° W K1 Dia d1 K2 Dia d2
1 43240 4 83400 Max. Min. A 52,4 47,6
2 71750 5 56500 T7DBB - T7DCB - T7DCC 125,000 124,937 2,0 9,5 180,0 18,0 113,14 14,0 B 26,2 22,2
- Dimensions - Weight : 61 kg T7/T67/T6C Industrial, Denison Vane Pumps
53 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7DCB / T7DCBS - Technical data T7/T67/T6C Industrial, Denison Vane Pumps
INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL) - T7DCB - B38 - B22 - B10
22 80
P1
20 Pe = 0,9 bar abs
24 cSt
16 75
Lw = Lp + 8 db (A)
14
12
70
10 P1 P2
8
P3
6
65
4
P3
2
0 60
0 50 100 150 200 250 300 0 40 80 120 160 200 240
Do not operate pump more than 5 seconds at any speed or viscosity Triple pump noise level is given with all stages discharging at the
if internal leakage is higher than 50% of theoretical flow. pressure value indicated on the curve.
Total leakage is the sum of each section loss under its respective
operating conditions.
6
n = 1000 RPM
5
n = 1500 RPM [24 cSt]
P1
4 n = 2500 RPM
3
1800
P1
2 = Shaft
=
1 P1 1600
keyed
F
0
0 30 60 90 120 150 180 210 240 1400 Fa
Power loss Ps [kW]
n = 1000 RPM
3 n = 1500 RPM [24 cSt]
P2
n = 2500 RPM
2 P2 1000
1 P2
800
0
P2-P3
0 40 80 120 160 200 240 280 600
3
n = 1000 RPM
2 n = 1500 RPM [24 cSt] P3 400
n = 2500 RPM
P3
1 200
P3
0 600 900 1200 1500 1800 2100 2400
0 50 100 150 200 250 300
Total hydromechanical power loss is the sum of each section loss Maximum permissible axial load Fa = 800 N
under its respective operating conditions.
54 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7DCC / T7DCCS - Technical data T7/T67/T6C Industrial, Denison Vane Pumps
INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL) - T7DCC - B31 - B22 - B22
22 80
20 P1
24 cSt Pe = 0,9 bar abs
nSérie
= 1000 RPM
16
Lw = Lp + 8 db (A)
14
12
70
10 P1
8
P2-P3
6
65
4
0 60
0 40 80 120 160 200 240 280 0 40 80 120 160 200 240
Do not operate pump more than 5 seconds at any speed or viscosity Triple pump noise level is given with all stages discharging at the
if internal leakage is higher than 50% of theoretical flow. pressure value indicated on the curve.
Total leakage is the sum of each section loss under its respective
operating conditions.
6
n = 1000 RPM
5 n = 1500 RPM [24 cSt]
n = 2500 RPM P1 1800
4
3 = Shaft
=
P1 1600
2 keyed
F
1 1400 Fa
P1
Power loss Ps [kW]
1000
3,5
3 n = 1000 RPM 800
n = 1500 RPM [24 cSt] P2-P3
2,5 n = 2500 RPM
2 P2-P3 600
1,5
1 P2-P3 400
0,5
0
200
0 40 80 120 160 200 240 280 600 900 1200 1500 1800 2100 2400
Total hydromechanical power loss is the sum of each section loss Maximum permissible axial load Fa = 1200 N
under its respective operating conditions.
55 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7DCC
/ T7DCCS - Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
56 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7DDB
/ T7DDBS - Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
57 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7DDB / T7DDBS - Technical data T7/T67/T6C Industrial, Denison Vane Pumps
INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL) - T7DDB - B31 - B31 - B10
22 80
P1-P2
20 Pe = 0,9 bar abs
16
75 υu = 32 cSt
Lw = Lp + 8 db (A)
14
12
70
10 P1-P2
8
6 P3
65
4
2 P3
0 60
0 50 100 150 200 250 300 0 40 80 120 160 200 240
Do not operate pump more than 5 seconds at any speed or viscosity Triple pump noise level is given with all stages discharging at the
if internal leakage is higher than 50% of theoretical flow. pressure value indicated on the curve.
Total leakage is the sum of each section loss under its respective
operating conditions.
6
n = 1000 RPM 2000
5 n = 1500 RPM [24 cSt]
n = 2500 RPM P1-P2
4 = =
1800
Shaft
F
3
P1-P2 keyed
2 1600 Shaft keyed N°1Fa
Shaft keyed N°1
Power loss Ps [kW]
1 P1-P2
0 1400
Load F [N]
Total hydromechanical power loss is the sum of each section loss Maximum permissible axial load Fa = 1200 N
under its respective operating conditions.
58 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
455,0 84,0
62,0 P2 P1 7,89
Ø
7,9 d2
31,5 P3
2,3 x 45°
Catalogue HY29-0001/UK
114,9
101,6
101,6
74,7
C.G.
ØS
K2
Ø 64,3
206,5
Ø d1
2,3 x 45°
91,2
e x 45°
M10 x 20 DEEP
31,75
SHAFT CODE 4
SAE CC INVOLUTE SPLINE DATA
Ø 31,70
59
3/8-16UNC x 19 DEEP 7/16-14UNC x 24 DEEP M12 x 22,3 DEEP-METRIC VERSION 56,0
M10 x 19 DEEP-METRIC VERSION M12 x 24 DEEP-METRIC VERSION 7,9
B 30,2 77,8 30,2 6,4 MAXI
68,0 91,0
10,0 7,9
50,0 KEY 9,52
50,8
KEY 10 x 8 9,47 38,0
2,3 x 45°
2,3 x 45°
58,7
130,2
Hydraulic Pumps
A
P3 S P1
182,2
P2
58,7
38,10
Ø 38,05
SHAFT CODE 3
38,018
SAE C INVOLUTE SPLINE DATA
41,0 MAXI
Ø 38,002
42,36 MAXI
CLASS 1-FLAT ROOT SID E FIT
M10 x 20 DEEP
M10 x 20 DEEP
J498b - PITCH 12/24
SHAFT CODE 5 SHAFT CODE 2 14 TEETH - 30° PRESSURE ANGLE
Keyed ISO R775 -G38M Keyed SAE CC
PRESSURE Ø C PRESSURE Ø 31,8 SUCTION Ø 101,6 PRESSURE Ø 31,8
Vierzon - France
Alternate connect. variables
Parker Hannifin
Shaft torque limits [ml/rev. x bar] Alternate mounting flange
Shaft Vi x p max. P1 + P2 + P3 Shaft Vi x p max. P1 + P2 + P3 Dia S 00 & M0 01 & M1
Series e x 45° W K1 Dia d1 K2 Dia d2
1 43240 4 66500 Max. Min. A 52,4 47,6
2 72306 5 53100 T7DDB 125,000 124,937 2,0 9,5 180,0 18,0 113,14 14,0 B 26,2 22,2
- Dimensions - Weight : 66 kg T7/T67/T6C Industrial, Denison Vane Pumps
3 61200 T7DDBS 127,000 126,950 1,5 12,7 181,0 17,5 114,50 14,3 C 25,4 19,0
6,4 MAXI
S 49,3
62,0
P2 P1
7,9 14 KEY 7,94
,3 7,89
31,5 P3
2,3 x 45°
Catalogue HY29-0001/UK
115,0
101,6
101,6
74,7
C.G.
127,00
114,5
Ø 64,3
Ø 126,95
206,5
Ø 17,5
2,3 x 45°
91,2
31,75
1,3 x 45°
Ø 31,70
35,27 MAXI
SHAFT CODE 4
M10 x 20 DEEP
( KEYED SAE C )
213,0 MOUNTING TORQUE : 190 Nm MOUNTING TORQUE : 190 Nm
56,0
7/16-14UNC x 24 DEEP 5/8-11UNC x 30 DEEP 7/16-14UNC x 22,3 DEEP 7,9
M12 x 24 DEEP-METRIC VERSION M16 x 30 DEEP-METRIC VERSION M12 x 22,3 DEEP-METRIC VERSION
6,4 MAXI
3/8-16UNC x 19 DEEP
30,2 77,8 30,2
60
84,0 91,0 M10 x 19 DEEP-METRIC VERSION
B 37,7
7,9 7,9
59,6 50,8 KEY 9,52
KEY 7.94
9,47
7.89
2,3 x 45°
2,3 x 45° 2,3 x 45°
A
P3 P2 S P1
182,2
130,2
58,7
58,7
Hydraulic Pumps
38,10
34,90
Ø 38,05
Ø 34,85
SHAFT CODE 3
42,36 MAXI
38,42 MAXI
SAE C INVOLUTE SPLINE DATA
M10 x 20 DEEP
M10 x 20 DEEP
CLASS 1-FLAT ROOT SIDE FIT
J498b - PITCH 12/24
SHAFT CODE 5 SHAFT CODE 2 14 TEETH - 30° PRESSURE ANGLE
(KEYED NO SAE) ( KEYED SAE CC )
PRESSURE Ø C PRESSURE Ø 31,8 SU CTION Ø 101,6 PRESSURE Ø 31,8
Vierzon - France
Parker Hannifin
Shaft torque limits [ml/rev. x bar] Alternate connect. variables
Shaft Vi x p max. P1 + P2 + P3 Shaft Vi x p max. P1 + P2 + P3 00 & M0 01 & M1
1 43240 4 66500 A 52,4 47,6
2 72306 5 55600 B 26,2 22,2
T7/T67/T6C Industrial, Denison Vane Pumps
C 25,4 19,0
61 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T67DDCS - Technical data T7/T67/T6C Industrial, Denison Vane Pumps
INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL) - T67DDCS - B31 - B31 - B22
22 80
24 cSt
20 P1-P2
Pe = 0,9 bar abs
10 cSt
nSérie
= 1000 RPM
16 75 υu = 32 cSt
Lw = Lp + 8 db (A)
14
12
70
10
P1-P2
8
P3
6
65
4
0 60
0 40 80 120 160 200 240 280 0 40 80 120 160 200 240
Do not operate pump more than 5 seconds at any speed or viscosity Triple pump noise level is given with all stages discharging at the
if internal leakage is higher than 50% of theoretical flow. pressure value indicated on the curve.
Total leakage is the sum of each section loss under its respective
operating conditions.
6
n = 1000 RPM
5 2000
n = 1500 RPM [24 cSt]
n = 2500 RPM P1-P2
4
1800
3
Shaft
= =
P1-P2 keyed
F
2 1600
Fa
Power loss Ps [kW]
0 400
0 40 80 120 160 200 240 280 600 900 1200 1500 1800 2100 2400
Total hydromechanical power loss is the sum of each section loss Maximum permissible axial load Fa = 1200 N
under its respective operating conditions.
62 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7EDB
/ T7EDBS - Technical data T7/T67/T6C Industrial, Denison Vane Pumps
INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL) - T7EDB - 062 - B35 - B04
33
85
Pe = 0,9 bar abs
30 24 cSt
n = 1000 RPM
P1 Série
24
Lw = Lp + 8 db (A)
21 P2
18
P1 75
15
12
P2
9 70
P3
6
P3
3
0 65
0 50 100 150 200 250 300 0 40 80 120 160 200 240
Do not operate pump more than 5 seconds at any speed or viscosity Triple pump noise level is given with all stages discharging at the
if internal leakage is higher than 50% of theoretical flow. pressure value indicated on the curve.
Total leakage is the sum of each section loss under its respective
operating conditions.
8
7 n = 1000 RPM
6 n = 1500 RPM [24 cSt] 1800
5 n = 2200 RPM P1
= =
4 P1
3 Shaft
F
1600
2 keye
P1 Fa
1
0 1400 Shaft keyed N°1
0 30 60 90 120 150 180 210 240
Power loss Ps [kW]
6
n = 1000 RPM 1200
Load F [N]
5
n = 1500 RPM [24 cSt] P2
4 n = 2200 RPM
3 P2 1000
2
1 P2
0 800
0 30 60 90 120 150 180 210 240
3
600
n = 1000 RPM
2 n = 1500 RPM [24 cSt] P3
n = 2200 RPM 400
P3
1
P3
0 200
0 50 100 150 200 250 300 600 1000 1400 1800 2200
Total hydromechanical power loss is the sum of each section loss Maximum permissible axial load Fa = 2000 N
under its respective operating conditions.
63 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7EDB
/ T7EDBS - Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
64 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
K Ød
120,0 148,4 133,3 42,9
8,2
100,0
K/2
P1 6,4 T7EDBS
ØZ
S KEY 11,11
P2 11,06
45°
P3
T7EDB/EDBS
63,5
139,7
115,0
74,7
101,6
Catalogue HY29-0001/UK
C.G.
ØS
273,0
49,30 MAX
171,3
44,45
2,3 x 45°
Ø 44, 40
106,0
e x 45° 1/2-13 UNC x 24 DEEP
1/2 13UNC-20 DEEP
(M12 x 20 DEEP-METRIC VERSION) 22,0 w
SHAFT CODE 2
( KEYED SAE D & E )
110,0 120,0 100,7
273,0 468,0
92,0
- Dimensions - Weight : 102 kg
65
8,0 48,8 35,7
77,8
30,2
3/8 - 16 UNC x 19 DEEP- 4 HOLES B 63,0
(M10 x 19 DEEP- METRIC VERSION) KEY 14 x 9
A
ØS
P3 P2 S P1
Hydraulic Pumps
69,8
58,7
130,2
208,9
SHAFT CODE 3
48,5 MAX
Ø 44, 975
M12 x 24 DEEP
Vierzon - France
Parker Hannifin
Shaft torque limits [ml/rev. x bar] Alternate mounting flange Alternate connect. variables
Shaft Vi x p max. P1 + P2 + P3 Dia S 00 & M0 01 & M1
Series e x 45° W K Dia Z Dia d
1 114600 Max. Min. A 52,4 47,6
3 126800 T7EDBS 165,100 165,050 2,0 9,0 224,5 - 20,6 C 25,4 19,0
120,0 148,4 133,3 42,9 100,0
K Ød
K/2 8,2
P1 6,4 T67EDCS
ØZ
S KEY 11,11
P2 11,06
45°
P3
T67EDC/EDCS
63,5
139,7
115,0
74,7
101,6
Catalogue HY29-0001/UK
C.G.
ØS
273,0
49,30 MAX
171,3
44,45
2,3 x 45°
Ø 44, 40
106,0
e x 45° 1/2-13 UNC x 24 DEEP
1/2 13UNC-20 DEEP
(M12 x 20 DEEP-METRIC VERSION) 22,0 w
SHAFT CODE 2
( KEYED SAE D & E )
110,0 120,0 100,7
273,0 468,0
92,0
- Dimensions - Weight : 102 kg
66
77,8
30,2
3/8 - 16 UNC x 19 DEEP- 4 HOLES B 63,0
(M10 x 19 DEEP- METRIC VERSION) KEY 14 x 9
A
ØS
P3 P2 S P1
69,8
58,7
130,2
Hydraulic Pumps
208,9
SHAFT CODE 3
48,5 MAX
Ø 44, 975
M12 x 24 DEEP
Vierzon - France
Parker Hannifin
Shaft torque limits [ml/rev. x bar] Alternate mounting flange Alternate connect. variables
Shaft Vi x p max. P1 + P2 + P3 Dia S 00 01
Series e x 45° W K Dia Z Dia d
1 114600 Max. Min. A 52,4 47,6
2 118340 T67EDC 250,000 249,928 2,0 9,0 - 315 22,0 B 26,2 22,2
T7/T67/T6C Industrial, Denison Vane Pumps
C 25,4 19,0
67 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T67EDC
/ T67EDCS - Technical data T7/T67/T6C Industrial, Denison Vane Pumps
INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL) - T67EDCS - 062 - B35 - B22
33 85
80 υ
24
Lw = Lp + 8 db (A)
21
P3
P2
18
75
15
12 P1
9 P2
70
P3
6
0
65
0 40 80 120 160 200 240 280
0 40 80 120 160 200 240
Do not operate pump more than 5 seconds at any speed or viscosity Triple pump noise level is given with all stages discharging at the
if internal leakage is higher than 50% of theoretical flow. pressure value indicated on the curve.
Total leakage is the sum of each section loss under its respective
operating conditions.
8
7 n = 1000 RPM
6 n = 1500 RPM [24 cSt] 1800
5 n = 2200 RPM P1
4 P1 =Shaft
=
3 1600
keye
F
2
P1
1 Fa
0 1400
Shaft keyed N°1
Power loss Ps [kW]
5 n = 1000 RPM
n = 1500 RPM [24 cSt] P2
4 n = 2200 RPM
3 1000
P2
2
1 P2 800
0
0 30 60 90 120 150 180 210 240
600
4
n = 1000 RPM
3 n = 1500 RPM [24 cSt] P3 400
2 n = 2200 RPM
P3
1 P3
0
200
0 40 80 120 160 200 240 280 600 1000 1400 1800 2200
Total hydromechanical power loss is the sum of each section loss Maximum permissible axial load Fa = 2000 N
under its respective operating conditions.
68 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7EEC
/ T7EECS - Technical data T7/T67/T6C Industrial, Denison Vane Pumps
INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL) - T7EECS - 052 - 052 - B25
35 85
Pe = 0,9 bar abs
24 cSt n Série
= 1000 RPM
80 Lw = Lp + 8 db (A)
25
20 P3
75
15
P1-P2
10 P3
70
0 65
0 40 80 120 160 200 240 280 0 40 80 120 160 200 240
Do not operate pump more than 5 seconds at any speed or viscosity Triple pump noise level is given with all stages discharging at the
if internal leakage is higher than 50% of theoretical flow. pressure value indicated on the curve.
Total leakage is the sum of each section loss under its respective
operating conditions.
7
n = 1000 RPM 2000
6 n = 1500 RPM [24 cSt]
5 n = 2200 RPM P1-P2
4
1800 = =
P1-P2 Shaft
3 F
keyed
2 1600 Fa
P1-P2
Shaft keyed N°1
Power loss Ps [kW]
1
0 1400
Load F [N]
1200
4
n = 1000 RPM
n = 1500 RPM [24 cSt] 1000
3
n = 2200 RPM
P3
800
2
P3
P3 600
1
0 400
0 40 80 120 160 200 240 280 600 1000 1400 1800 2200
Total hydromechanical power loss is the sum of each section loss Maximum permissible axial load Fa = 2000 N
under its respective operating conditions.
69 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
T7EEC
/ T7EECS - Ordering Code T7/T67/T6C Industrial, Denison Vane Pumps
70 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
273,00
119,6 160,5
515,2
168,3 42,9 10,0
92,0
136,50 W
e x 45°
63,00
KEY 14 h9
T7EEC/EECS
139,7
Z
K/2
115,0
115,0
Ø
75,0
Catalogue HY29-0001/UK
C.G.
ØS
K
45,000
273,00
202,7
Ø 44,975
48,5 maxi
74,5
3,0 x 45°
118,0
136,50
Ød
71
(M12 x 23.4 DEEP - METRIC VERSION)
77,8 35,7
35,7
3 x 45°
69,85
69,85
130,2
A
210
ØS
P3 P2 S P1
Hydraulic Pumps
SHAFT CODE 4
SAE D & E SPLINED SHAFT
CLASS 1- J498b -8/16 D.P.
13 TEETH -30° PRESSURE ANGLE
FLAT ROOT SIDE FIT
Vierzon - France
Parker Hannifin
Shaft torque limits [ml/rev. x bar] Alternate mounting flange Alternate connect. variables
Shaft Vi x p max. P1 + P2 + P3 Dia S 00 & M0 01 & M1
Series e x 45° W K Dia Z Dia d
2 118340 Max. Min. A 52,4 47,6
4 126800 T7EEC 250,000 249,928 2,0 9,0 - 315 22,0 B 26,2 22,2
- Dimensions - Weight : 114,8 kg T7/T67/T6C Industrial, Denison Vane Pumps
C 25,4 19,0
T7BB/T7BBS 00 01 02 03 04 05 06 07
T6CC P1-P2 P1-P2 S-P1-P2 P1-P2 P1 P1 P1 P1-S
S S
T67CB S S
P2 P2
P2
T7DB/T7DBS S S-P2
08 09 10 11 12 13 14 15
T67DC P1-S P1-S P1 P1 P1 P1 P1 P1
T7EB/T7EBS P2
S
S
P2 P2
P2
P2 S S
T67EC P2 P2 S P2 S
16 17 18 19 20 21 22 23
P1 P1 P1 P1 P1 P1 P1 P1
P2 P2 P2 P2
S S S S
P2 P2 P2 P2
S S S S
24 25 26 27 28 29 30 31
P1-S P1-S P1-S P1-S P1 P1 P1 P1
P2 P2 P2 P2
S S S S
P2 P2 P2 P2
T7DD/T7DDS 00 01 02 03 04 05 06 07
T7ED/T7EDS P1-P2 P1-P2 S-P1-P2 P1-P2 P1 P1 P1 P1-S
S S
T7EE/T7EES S S
P2 P2
P2
S S-P2
08 09 10 11 12 13 14 15
P1-S P1-S P1 P1 P1 P1 P1 P1
S P2 P2
P2 S P2
P2 S S
P2 P2 S P2 S
T7DBB/T7DBBS 00 01 02 03 04 05 06 07
P1-P2-P3 P1-P2-P3 S-P1-P2-P3 P1-P2-P3 P1 P1 P1 P1-S
T7DCB/T7DCBS S S
P2
S S P2 P2
T7DCC/T7DCCS P3 P3
P3
S S-P2-P3
T7DBB/T7DBBS
08 09 10 11 12 13 14 15
T67DDCS P1-S P1-S P1 P1-P2 P1-P2 P1-P3 P1 P1-P3
S
T7EDB/T7EDBS P2
P3
S S
P3
P2
S
S
P2
T7EEC/T7EECS 16 17 18 19 20 21 22 23
S-P1-P2 S-P1-P2 S-P1-P2 S-P1-P3 S-P1-P3 S-P1-P3 P1-P2 P1
S
P3
P3 P3 P2 P2 S
P2
P3
P3 P2
24 25 26 27 28 29 30 31
P1 P1 P1 P1-P3 P1-S P1-S P1-S P1-S
P2
P3 P2 P2 P3
S
P2 P3 P2 P3
P3
S S S-P2 P3 P3 P2 P2
32 33 34 35 36 37 38 39
P1-S P1-S P1-P2 P1-P2 P1-P2 P1-P2 P1-P2 P1-P2
P2 S S P3 S S
P3 P3 P3 P3
P2 P3
P3 P3 S S
40 41 42 43 44 45 46 47
P1-P3 P1-P3 P1-P3 P1-P3 P1-P3 P1-P3 P1 P1
S
P2 P2 P2 S
S S S S
P2 P2 P3 P2
P2 P2 S S P3
48 49 50 51 52 53 54 55
P1 P1 P1 P1 P1 P1 P1 P1
S S
P3 P3 P3 P2 P3
P2 P3 P2 S S
P2 P2
P2 S-P2 S-P2 S-P3 S-P3 P3
56 57 58 59 60 61 62 63
P1 P1 P1 P1 P1 P1 P1 P1
S P2 S S P2 P2 P3
P3 P3
P3 S P2 P3 S P2 S
P3
P2 P2 P3 S P3 S P2
72 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
Porting Diagrams T7/T67/T6C Industrial, Denison Vane Pumps
T7DBB/T7DBBS 64 65 66 67 68 69 70 71
T7DCB/T7DCBS P3 P1 P1 P3 P1 P1 P3 P1 P1 P3 P1 P1
T7DCC/T7DCCS P2 P2 P2 P2
P3 P3 P3 P3
S S S S S-P2 S-P2 S-P2 S-P2
T7DBB/T7DBBS
72 73 74 75 76 77 78 79
T67DDCS P3 P1 P1 P3 P1 P1 P3 P1-P2 P1-P2 P3 P1-P2 P1-P2
T7EDB/T7EDBS P2 P2 P2 P2
P3 P3 P3 P3
T67EDC/T67EDCS S S S S S S S S
T7EEC/T7EECS 80 81 82 83 84 85 86 87
P3 P1 P1 P3 P1 P1 P3 P1 P1 P3 P1 P1
S S S S
S S S S
P2 P2 P2 P2
P3 P3 P3 P3
P2 P2 P2 P2
88 89 90 91 92 93 94 95
P3 P1 P1 P3 P1 P1 P3 P1-P2 P1-P2 P3 P1-P2 P1-P2
P2 P2 P2 P2
S S S S
S S S S
P3 P3 P3 P3
96 97 98 99 1A 1B 1C 1D
P3 P1-S P1-S P3 P1-S P1-S P3 P1-S P1-S P3 P1-S P1-S
P2 P2 P2 P2
P3 P3 P3 P3
P2 P2 P2 P2
1E 1F 1G 1H 1J 1K 1L 1M
P3 P1-S P1-S P3 P1-S P1-S P3 P1-S-P2 P1-S-P2 P3 P1-S-P2 P1-S-P2
P2 P2 P2 P2
P3 P3 P3 P3
1N 1P 1R 1S 1T 1U 1V 1W
P3 P1 P1 P3 P1 P1 P3 P1 P1 P3 P1 P1
S S S
P2 S S S S S
P2 P2 P2
P3 P3 P3 P3
P2 P2 P2 P2
1X 1Y 1Z 2A 2B 2C 2D 2E
P3 P1 P1 P3 P1 P1 P3 P1-P2 P1-P2 P3 P1-P2 P1-P2
S
S S S S S S S
P2
P2 P2 P2
P3 P3 P3 P3
P1
S P2 P3 P2 P3
02 16 17 18 20 30 08 31
19 07 28 32 21 33 29 09
01 22 34 38 40 48 10 58
13 04 46 47 45 49 59 23
00 36 11 37 27 51 05 50
42 24 53 60 43 62 52 25
03 39 35 12 41 63 14 57
44 26 61 56 15 54 55 06
73 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
Notes T7/T67/T6C Industrial, Denison Vane Pumps
74 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Catalogue HY29-0001/UK Hydraulic Pumps
General Information T7/T67/T6C Industrial, Denison Vane Pumps
- This document and other information from Parker-Hannifin Corporation, its subsidiaries
and authorized distributors provide product or system options for further investigation by users
having technical expertise.
- The user, through its own analysis and testing, is solely responsible for making the
final selection of the system and components and assuring that all performance, endurance,
maintenance, safety and warning requirements of the application are met. The user must analyze
all aspects of the application, follow applicable industry standards, and follow the information
concerning the product in the current product catalog and in any other materials provided from
Parker or its subsidiaries or authorized distributors.
- To the extent that Parker or its subsidiaries or authorized distributors provide component or
system options based upon data or specifications provided by the user, the user is responsible for
determining that such data and specifications are suitable and sufficient for all applications and
reasonably foreseeable uses of the components or systems.
Offer of Sale
Please contact your Parker representation for a detailed ’’Offer of Sale’’.
75 Parker Hannifin
Pump & Motor Division Europe
Vierzon - France
Parker Worldwide
Europe, Middle East, Africa HU – Hungary, Budaörs UK – United Kingdom, Warwick
Tel: +36 23 885 470 Tel: +44 (0)1926 317 878
AE – United Arab Emirates, [email protected] [email protected]
Dubai
Tel: +971 4 8127100 IE – Ireland, Dublin ZA – South Africa, Kempton Park
[email protected] Tel: +353 (0)1 466 6370 Tel: +27 (0)11 961 0700
[email protected] [email protected]
AT – Austria, Wiener Neustadt
Tel: +43 (0)2622 23501-0 IL – Israel
[email protected] Tel: +39 02 45 19 21 North America
[email protected] CA – Canada, Milton, Ontario
AT – Eastern Europe, Wiener
Neustadt IT – Italy, Corsico (MI) Tel: +1 905 693 3000
Tel: +43 (0)2622 23501 900 Tel: +39 02 45 19 21 US – USA, Cleveland
[email protected] [email protected] Tel: +1 216 896 3000
AZ – Azerbaijan, Baku KZ – Kazakhstan, Almaty
Tel: +994 50 2233 458 Tel: +7 7273 561 000 Asia Pacific
[email protected] [email protected]
AU – Australia, Castle Hill
BE/LU – Belgium, Nivelles NL – The Netherlands, Oldenzaal Tel: +61 (0)2-9634 7777
Tel: +32 (0)67 280 900 Tel: +31 (0)541 585 000
[email protected] [email protected] CN – China, Shanghai
Tel: +86 21 2899 5000
BG – Bulgaria, Sofia NO – Norway, Asker
Tel: +359 2 980 1344 Tel: +47 66 75 34 00 HK – Hong Kong
[email protected] [email protected] Tel: +852 2428 8008
© 2018 Parker Hannifin Corporation. All rights reserved. Catalogue HY29-0001/UK 04/2018