Electron Comp

A competency survey evaluated a student, Alicia Wilson, in external beam electron planning tasks. The reviewer assessed Alicia as satisfactory in all tasks except adding bolus, which was not applicable. Comments noted Alicia discussed a prescription with a physician for treatment of a rib, planned with and without bolus, and had to split monitor units between fields to satisfy the prescription due to system limitations. Overall, Alicia passed the competency.

Uploaded by

api-484027891
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
40 views1 page

Electron Comp

A competency survey evaluated a student, Alicia Wilson, in external beam electron planning tasks. The reviewer assessed Alicia as satisfactory in all tasks except adding bolus, which was not applicable. Comments noted Alicia discussed a prescription with a physician for treatment of a rib, planned with and without bolus, and had to split monitor units between fields to satisfy the prescription due to system limitations. Overall, Alicia passed the competency.

Uploaded by

api-484027891
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Survey: "External Beam ELECTRON Planning Competency"

Reviewer: Clinical Instructors (BROWN, Issac)


Reviewee: Students (Wilson, Alicia)
Survey Period: 3/26/2020
Completed: 5/5/2020 8:27:15 AM CT

1. Please assign each task a score of Satisfactory or Unsatisfactory.


Unsatisfactory in any essential task constitutes competency failure.
The student will repeat the competency at a later date.

Discusses the plan prescription with the physician. Satisfactory


Additional Comment:  Rt. posterior 8th rib single fraction (800x1) 16E
9cm round cut out

Loads the patient imaging studies into the planning computer. Satisfactory

Contours the appropriate anatomy on the image data set. Satisfactory

Successfully places eld/SSD using simulation data. Satisfactory


Additional Comment:  used 105 ssd

Correctly generates plan using appropriate cone/cutout size. Satisfactory

Generates plan with correct reference depth. Satisfactory

Generates plan with appropriate energy. Satisfactory


Additional Comment:  16E

Correctly adds the appropriate thickness of bolus. N/A


Additional Comment:  no bolus

Generates bolus to adequately cover treatment eld borders. N/A


Additional Comment:  no bolus

Accurately calculates daily dose for treatment eld using prescription % Satisfactory
and weighting. Additional Comment:  85%

Accurately generates a single fraction DVH or composite DVH (for correct Satisfactory
# of fractions).

Communicates effectively with physician for plan review and makes Satisfactory
changes as requested.

Exports/Prints appropriate plan data. Satisfactory

Performs hand veri cation calculations for plan MU settings using Satisfactory
data/calc books

Enters in correct parameters for patient chart. Satisfactory

Performs pretreatment checks/calculations. Satisfactory

Observes patient treatment. Satisfactory

2. Overall rating:

Pass

3. Additional Comments:

Alicia planned two plans. One with and one without bolus to show the physician. He ended up choosing the no bolus plan. In our Eclipse system, an overage of 1000mu's
per eld are not allowed. Alicia had to split the mu's in two equal elds to satisfy the Rx. Great job!!

Responses as of 5/5/2020 4:20:10 PM CT