New etaSMART Series


Automatic Power Factor Controllers
Power
factor
correction
– now easier
than ever.
New
etaSMART
Series

Brought to you by Larsen & Toubro – India's largest The L&T Advantage • Manual & Automatic operation • Capacitor health check monitoring function
manufacturer of LT switchgear – the etaSMART Series - In Auto Mode, etaSMART automatically regulates ensures that capacitor is declared faulty if its
automatically corrects the power factor, with the help • Avoid cascading of multiple controllers. the power factor power falls beyond a certain limit.
of contactors for the connection and disconnection of Available up to 16 steps - While in Manual Mode, etaSMART can help
• You can schedule the maintenance of your
capacitor banks. • Space-saving. Compact size of 96x96 mm in testing the power factor correction system
installation by reading the record of the number
for controller up to 8 steps • Option of LIFO, FIFO, and Intelligent control mode. of switching of each step
Packed with a specially formulated optimisation Choose any of these control modes. By default,
• CT Secondary 1A/5A. Wiring is now even • Last relay output contact can be configured as
program, the controller ensures accurate power factor it is set as Intelligent; this mode selects the best
easier as CT input terminals are common Step or Alarm. Second-last relay output can be
control at the set point and hunt free operation. combination of capacitor bank for compensation
for either of the CT variants. configured as Step or Fan control
with minimum switching to achieve the desired
Now, configuring etaSMART is even easier. There are • Automatic detection of CT polarity saves time power factor • Ambient temperature monitoring via internal
two ways to do so. You can either follow a few simple and effort. etaSMART detects the CT reversal sensor
and automatically corrects it. • Instant information on the quality of your power
steps and manually configure the controller, or you
system. etaSMART measures current THD and
can just initiate AUTO PROGRAM and the controller
voltage THD, and alerts you if levels go beyond
will configure itself.
set limits.
Product Dimensions

Technical Specifications

etaSMART 4R, etaSMART 6R and etaSMART 8R


Parameters etaSMART Series Automatic Power Factor Controller

No. of steps 4, 6, 8, 12, 14, 16 96 92

Current input 1A / 5A etaSMART 4R

Voltage input 415 - 440 VAC

70.9
1 2 3 4

92
96

58.3
Rated Frequency 50-60 Hz LEAD

LAG

ALARM

AUTO

MANUAL

Display parameters PF, V, I, Required KVAr, KVA, KW, KVAr, V-THD, I-THD, Hz, Temperature
AUTOMATIC POWER FACTOR CONTROLLER

Record parameters Min/Max V, Max A, Max KVA/KW/KVAr, Max V-THD, Max I-THD, Max Temperature

Control Range Power factor range - 0.3 Lag to 0.3 Lead

Control Mode Intelligent mode, LIFO, FIFO

Operation Mode Automatic, Manual etaSMART 12R, etaSMART 14R & etaSMART 16R

Alarms Over / Under compensation, Over / Under voltage, Over / Under Current, 144 138
High V-THD, High I-THD, Over / Under frequency, Over temperature, No-volt release
etaSMART 16R

Power consumption 6.5 VA


5

Operating temperature -20 to +60 °C


1 2 3 4 6 7 8 9 10 11 12 13 14 15 16

71.6

138
144

58.3
LEAD

LAG

Relative humidity < 90 % ALARM

AUTO

MANUAL

Mounting Flush
AUTOMATIC POWER FACTOR CONTROLLER

Degree of protection IP20 (Front IP54)

Compliances EN 61010 - 1, IEC/EN 61000-6-2, IEC/EN 61000-6-4, EN 61326


NOTE: All dimensions are in mm
etaSMART 16R
etaSMART 14R
etaSMART 12R
etaSMART 8R
etaSMART 6R
4.2 WIRING DIAGRAM

etaSMART 4R
415-440 V 50/60 Hz MAX 6 VA
Use 60/78° C Copper ( Cu ) Conductor IEC/EN 61010-1
Wire Range 30 - 12 AWG Stranded Or Solid
Terminal Torque 1.5 N-m
Power Quality Solutions

etaPRO v3.0

SP 50976

L&T Electrical & Automation


CBMC/RDP/12/2017

Customer Interaction Center (CIC)


BSNL / MTNL (toll free): 1800 233 5858 Reliance (toll free): 1800 200 5858 Tel: 022 6774 5858 Email: [email protected] Web: www.Lntebg.com

Regd. Office: Larsen & Toubro Limited, L&T House, N. M. Marg, Ballard Estate, Mumbai - 400 001, INDIA CIN: L99999MH1946PLC004768

You might also like