Data Sheet Ejector PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

DATA SHEET NO.

BOPL-EJR-DS-01
SHEET NO. 1 OF 1
DATA SHEET FOR DATE 17/01/2014 Rev. 1
STEAM CONDENSER EJECTOR PREPARED BY SMA
Byco Oil Pakistan Ltd CHECKED BY MS
Mouza Kund, Hub APPROVED BY RZ

STEAM CONDENSER EJECTOR


Items Units Requirement
Tag Number 21H-1/1A Condenser:
Quantity Required No. 2 Yes
VENDOR
Type - VTA Ejector type:
Make - Any wellknown OEM Single Stage Single Element
Model - VTA

OPERATING CONDITION( PER UNIT)


ENTRAINED GAS Testing:
Performance MFR`s STD.
Type of gas - Air- Steam Mixture Hydrostatic Per H.E.I
Dry Gas (air) Lbs/hr 87
Water Vapor (steam) Lbs/hr 211
Total Gas Lbs/hr 298
Inlet temperature Deg F 170 Weight:
Inlet Pressure psia 5.8 VTA
Discharge pressure psia 15.5

MOTIVE STEAM Accessories and materials (VTC)


Gas Inlet Valve
Design pressure psig 180
Maximum pressure psig 200
Minimum pressure psig 150
Design Temperature Deg F Saturated
Maximum temperaure Deg F
Stem consumption Lbs/Hr 531

COOLING WATER See Exchanger datasheet

CONNECTION (size & rating)

Steam inlet ASA VTA


Gas Inlet ASA VTA
Gas outlet ASA VTA

Ejector Material
Diffuser Steel(VTC)
Suction Chamber Steel(VTC)
Steam Nozzle Steel(VTC)
Nozzle Extensions X 22 Cr Mo V (VTC)
Steam Chest Steel(VTC)
Nozzle Plate Steel(VTC)

Note:
1 VTA = Vendor to advice
2 VTC = Vendor to confirm
3 The Ejector and all auxilliaries should conform to H.E.I. (Heat Exchanger Institute) specifications