2800 Series Digital Panel Meters: Inputs Specifications
2800 Series Digital Panel Meters: Inputs Specifications
2800 Series Digital Panel Meters: Inputs Specifications
Panel Meters
Inputs Specifications
DC Voltage DISPLAY
Display Maximum Type 7- segment, red LED
Range Resolution Input Height 0.56” (14.2mm)
200mV 100μV 100MΩ Decimal Point Jumper-selectable
2V 1mV 100MΩ Overrange Indication All digits blink “0”
20V 10mV 10MΩ
200V 100mV 10MΩ POWER REQUIREMENTS
AC Voltages 120V, ±10%, 50Hz to 400 Hz, 3VA
AC Current DC Voltages 5 DCV
Display Maximum Rated Circuit to Ground Voltage 250 DCV (Models 2865 and 2869) or
Range Resolution Input -4.06 to +4.5 DCV (Model 2866)
20μA 10nA 20mA
200μA 100nA 20mA ACCURACY @ 23°C, ±2°C ± (1.0% of input +5 counts) 45Hz to 1KHz
2mA 1μA 20mA
20mA 10μA 100mA ENVIRONMENTAL
200mA 100μA 1mA Operating Temperature 0 to 55ºC
Storage Temperature -40 to 60°C
DC Current Relative Humidity 0 to 85°, non-condensing
Display Maximum Temperature Coefficient ± (0.1% of input) ± 0.5 count / per °C
Range Resolution Input Warmup time 15 minutes
20μA 10nA 20mA
200μA 100nA 20mA A TO D CONVERSION
2mA 1μA 20mA Technique Dual slope
20mA 10μA 100mA Rate 2.5 samples / second-nominal
200mA 100μA 1mA
MECHANICAL
Bezel 1.93” x 3.9” (49mm x 99mm)
Depth 4.72” (120mm)
Panel cutout 1.68” x 3.622” (42.72mm x 92mm)
Weight 12.5 oz. (354.3 g)
1 Rev. 08-21-13
2800 Series Digital
Panel Meters
24506 2865 0-2 DCmA 120 VAC Turn the screws in each bracket until they firmly contact the
24507 2865 0-20 DCmA 120 VAC panel surface.
24508 2865 0-200 DCmA 120 VAC
2 Rev. 08-21-13