RGA22G Scale Guide: A B C DH
RGA22G Scale Guide: A B C DH
RGA22G Scale Guide: A B C DH
The RGA22G scale guide is mounted in place of any Renishaw RGH22 readhead and
uses the motion of the axis to apply RGS-S tape scale parallel to the guideway whilst
simultaneously removing the backing paper - a one man, one hit operation.
Scale installation
● Prepare scale and surface
● Ensure scale is cut to correct length and mounting surface has been prepared (refer to
RGS-S scale installation guide for details)
Mounting screws
Readhead
mounting RGA22G scale guide
bracket
Splitter screw
Figure 1
Limit of travel
Limit stop
Direction of scale
application
Splitter screw
Backing paper
Figure 2 20mm
RGA22G scale guide
(continued overleaf) Start of measuring length
a b c dh
INSTALLATION INSTRUCTION SHEET
Part No. M-9531-1281
● Load the scale into the scale guide
● Remove the splitter screw (see figure 1) from the scale guide body
● Separate the backing paper from the first 40mm of scale and feed it into the scale
guide as shown in figure 2
● Relocate the splitter screw behind the backing paper as shown in figure 2
● Push the scale carefully through to the end of scale mark, ensuring that it does not
stick to the mounting surface until it is in position. NOTE to prevent the scale sticking
to the mounting surface during this operation it may be necessary to re-apply
approximately 20mm of backing paper to the end of the scale before inserting through
scale guide. This can then be removed before to fitting end clamps.
● Attach the end of the scale to the mounting surface with light finger pressure
● Ensure complete adhesion of the scale to the mounting surface by applying firm finger
pressure along the full length of the scale from the centre outwards to each end
● Fit RGC-F end clamps (refer to RGS-S scale installation guide for details)
Straighten coils to
withdraw scale
DO NOT remove the scale for refitting or use elsewhere once it has been applied to the mounting surface.
The scale can be applied once only.
a b c dh USA, Renishaw Inc France, Renishaw SA Switzerland, Renishaw AG Renishaw’s Representative Offices
Tel +1 847 843 3666 Tel +33 1 64 61 84 84 Tel +41 55 410 66 66 People’s Republic of China, Beijing
Renishaw plc Fax +1 847 843 1744 Fax +33 1 64 61 65 26 Fax +41 55 410 66 69 Tel +86 10 6461 2689
Encoder Products Division Fax +86 10 6461 2687
New Mills, Wotton-under-Edge Japan, Renishaw KK Italy, Renishaw SpA Hong Kong, Renishaw (Hong Kong) Ltd Singapore
Gloucestershire GL12 8JR, UK Tel +81 3 5350 2201 Tel +39 11 9 66 10 52 Tel +852 2753 0638 Tel +65 438 2778
Tel: +44 (0)1453 523 634 Fax +81 3 5350 2207 Fax +39 11 9 66 40 83 Fax +852 2756 8786 Fax +65 438 4780
(07000 RENISHAW) Indonesia, Jakarta
Fax: +44 (0)1453 523 760 Germany, Renishaw GmbH Spain, Renishaw Iberica SA Brazil, Renishaw Latino America Ltda Tel/fax +62 21 424 3934
E mail [email protected] Tel +49 712 797 960 Tel +55 11 7295 2866 Tel +55 11 7295 2866 India, Bangalore (liaison office)
Internet http://www.renishaw.com Fax +49 712 788 237 Fax +55 11 7295 1641 Fax +55 11 7295 1641 Tel/fax +91 80 224 3223
© 1999 Renishaw plc Renishaw reserves the right to change specifications without notice Printed in England 499 Part No M-9531-1281-02