Homework 2 - Jose Rowell E. Macabanti

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

Jose Rowell E.

Macabanti

2008-00063

Homework #2- Construction technology

MATERIAL SPECIFICATION

A. Ready-Mix concrete, cement, reinforcement


 Ready-Mix Concrete : 4000psi G3/4 @ 28 days
 Cement : ASTM C-150 Type I, III*
 Reinforcement: Steel fiber 3D 80/60BG, 20kg/m3
B. Concrete block works:
 Shall have a minimum ultimate compressive strength @ 28 days as follow:

100 mm thick non-load bearing CMU, f’m = 2.4 mpa (350 PSI)

150 mm thick non-load bearing CMU, f’m = 2.4 mpa (350 PSI)

CHB should be Filled partially with grout. Concrete grout shall have a minimum
compressive strength of 10.30 mpa (1500 PSI) @ 28 days
 Unless indicated CMU reinforcement shall be 10mm diam. Hor. Bars @ 600 and 10mm
diam. Vert. Bars @ 600
C. Structural Steel
 Members fabricated from plate or bar stock shall have flanges and webs joined on one
side of the web by a continuous welding process and will conform to the physical
specifications of ASTM A572 (Grade 50) or equivalent and having a minimum yield
strength of 50,000 P.S.I. (345 MPa).
 Members fabricated by cold forming process shall conform to the physical specifications
of ASTM A570 (Grade 50) or A1011 for black steel and A653 for galvanized (Grade 50) or
equivalent and having a minimum yield strength of 50,000 P.S.I (345 MPa).
 Members fabricated from hot rolled structural shapes shall conform to the physical
specifications of ASTM A572 (Grade 50) or equivalent and having a minimum yield
strength of 50,000 P.S.I. (345 MPa).
 Rod and angle bracing shall conform to the physical specifications of ASTM A36 (or
equivalent) and having a minimum yield strength of 36,000 P.S.I. (250 MPa).
 Cable bracing shall conform to the physical specifications of ASTM A475 (or equivalent)
 Roof and wall cladding shall conform to the physical specifications of ASTM A792 Grade
50 or ASTM A653 Grade 50 (or equivalent) and having a minimum yield strength of
50,000 P.S.I. (345 MPa).
 All other miscellaneous secondary members shall have minimum yield strength of
36,000 P.S.I. (250 MPa)
D. Glass doors/Windows
 Glass doors: Frameless glass door using Gentry floor hinge and fittings, 1-1/4 x 24
Stainless h-type handle, ½ clear tempered glass and complete accessories
 Windows: Aluminum fixed glass and aluminum awning window using aluminum tubular
1-3/4 x 4 framing, snap on base and cover , YC-Section for awning window with stainless
hinges, cam handle, ¼ clear glass and complete accessories