Drives are employed for systems that require motion control – e.g. transportation system, fans,
robots, pumps, machine tools, etc. Prime movers are required in drive systems to provide the
movement or motion and energy that is used to provide the motion can come from various
sources: diesel engines, petrol engines, hydraulic motors, electric motors etc.
Drives that use electric motors as the prime movers are known as electrical drives
A typical conventional electric drive system for variable speed application employing multi-
machine system is shown in Figure 1. The system is obviously bulky, expensive, inflexible and
require regular maintenance. In the past, induction and synchronous machines were used for
constant speed applications – this was mainly because of the unavailability of variable frequency
supply.
Ia
variable
fixed speed
variable
AC speed DC DC
DC Load
motor generator motor
If
With the advancement in power electronics, microprocessors and digital electronics, typical
electric drive systems nowadays are becoming more compact, efficient, cheaper and versatile –
this is shown in Figure 2. The voltage and current applied to the motor can be changed at will
by employing power electronic converters. AC motor is no longer limited to applications where
only AC source is available, however, it can also be used when the power source available is DC
or vice versa
Power
Power Processor Motor Load
Source (Power electronic
Converters)
feedback
Control Control
Unit
1
Figure 2 Modern Electric drive system employing power electronic converters
Electric drives is multi-disciplinary field. Various research areas can be sub-divided from
electric drives as shown in Figure 3.
• Utility interface
• Renewable energy
• Machine design
• Speed sensorless
• Machine theory
• Non-linear control
• Real-time control
• DSP application
• PFC
• sensors
• Speed sensorless
• Power electronic converters
a) Motors
Motors obtain power from electrical sources. They convert energy from electrical to
mechanical - therefore can be regarded as energy converters. In braking mode, the flow of
power is reversed. Depending upon the type of power converters used, it is also possible for
the power to be fed back to the sources (regenerative braking) rather than dissipated as heat
(dynamic braking).
There are several types of motors used in electric drives – choice of the type used depends on
applications, cost, environmental factors and also on the type of sources available. Broadly,
they can be classified as either DC or AC motors:
DC motors (wound or permanent magnet)
AC motors
Induction motors – squirrel cage, wound rotor
Synchronous motors – wound field, permanent magnet
Brushless DC motor – require power electronic converters
Stepper motors – require power electronic converters
Synchronous reluctance motors or switched reluctance motor – require power electronic
converters
2
Since the electrical sources are normally uncontrollable, it is therefore necessary to be able
to control the flow of power to the motor – this is achieved using power processor or power
modulator. With controllable sources, the motor can be reversed, brake or can be operated
with variable speed. Conventional methods used, for example, variable impedance or relays,
to shape the voltage or current that is supplied to the motor – these methods however are
inflexible and inefficient. Modern electric drives normally used power electronic converters to
shape the desired voltage or current supplied to the motor. In other words, the characteristic
of the motors can be changed at will. Power electronic converters have several advantages
over classical methods of power conversion, such as :
• More efficient – since ideally no losses occur in power electronic converters
• Flexible – voltage and current can be shaped by simply controlling the switching
functions of the power converter
• Compact – smaller, compact and higher ratings solid–state power electronic devices are
continuously being developed – the prices are getting cheaper.
Converters are used to convert and possibly regulate (i.e. using closed-loop control) the
available sources to suit the load i.e. motors. These converters are efficient because the
switches operate in either cut-off or saturation modes
Controlled
Diode DC-DC
rectifier
rectifier converter
control control
DC to AC
Inverter
DC-DC Inverter (PWM)
converter (six-step)
DC to DC
DC-DC
Converter
control
AC to AC
3
Matrix
Converter
control
c) Control Unit
The complexity of the control unit depends on the desired drive performance and the type of
motors used. A controller can be as simple as few op-amps and/or a few digital ICs, or it can
be as complex as the combinations of several ASICs and digital signal processors (DSPs).
The types of the main controllers can be:
• Analog circuit - which is noisy, inflexible. However analog circuit ideally has infinite
bandwidth.
• digital circuit – immune to noise, configurable. The bandwidth is obviously smaller than
the analog controller’s – depends on sampling frequency
• DSP/microprocessor – flexible, lower bandwidth compared to the digital circuit. DSPs
perform faster operation than microprocessors (multiplication in a single cycle). With a
DSP/microprocessor, complex estimations and observers can be easily implemented.
The control unit has to be electrically isolated from the power converters for the following
reasons:
• Malfuction in power circuit may damage control circuit if no electrical isolation is
present.
• Safety for the operator – the high voltage and/or high current faulty condition in
the power circuit can be conducted to the control circuit normally maintained by
an operator/user
• Avoid conduction of harmonic to control circuit. Power electronic converters
generate harmonics that can conduct to the control circuit thus interfering with
its operation.
Electrical isolation can be established using opto-coupler or pulse transformers.
d) Source
Electrical sources or power supplies provide the energy to the electrical motors. For high
efficiency operation, the power obtained from the electrical sources need to be regulated
using power electronic converters
Power sources can be of AC or DC in nature and normally are uncontrollable, i.e. their
magnitudes or frequencies are fixed or depend on the sources of energy such as solar or
wind. AC source can be either three-phase or single-phase; 3-phase sources are normally for
high power applications
e) Sensors
Sensors for voltage, current, speed or torque are required for closed-loop operation and
protections in electrical drive systems. Again, the signals from these sensors have to be
isolated from the control unit for the same reasons as explained before. Electrical isolation
in voltage and current sensors are obtained using, for example, hall effect sensors. The
terms ‘sensorless drives’ in electric drive is referred to drive without mechanical speed
sensors installed. The speed in sensorless drive is estimated using motor terminal variables
i.e. voltages and currents.
There can be several factors that affect the selection of different configuration of electrical drive
system such as:
a) Torque and speed profile - determine the ratings of converters and the quadrant of
operation required.
b) Capital and running cost – Drive systems will vary in terms of start-up cost and running
cost, e.g. maintenance.
4
c) Space and weight restrictions
d) Environment and location
Control unit:
• DC drives: Simple control – decoupling torque and flux by mechanical commutator – the
controller can be implemented using simple analog circuit even for high performance
torque control. This means that cheaper cost for the controller.
• AC drives, the types of controllers to be used depend on the required drive performance –
obviously, cost increases with performance. Scalar control drives technique does not
require fast processor/DSP whereas in Field Oriented Control (FOC) or Direct Torque
Control (DTC) drives, DSPs or fast processors are normally employed.
Performance:
• In DC motors, flux and torque components are always perpendicular to one another
thanks to the mechanical commutator and brushes. The torque is controlled via the
armature current while maintaining the field component constant. Fast torque and
decouple control between flux and torque components can be achieved easily.
• In AC machines, in particular the induction machines, magnetic coupling between
phases and between stator and rotor windings makes the modeling and torque control
difficult and complex. Control of the steady state operating conditions is accomplished
by controlling the magnitude and the frequency of the applied voltage; which is known
as the scalar control technique. This is satisfactory in some applications. The transient
states or the dynamics of the machine can only be controlled by applying the vector
control technique whereby the decoupling between the torque and flux components is
achieved through frame transformations. Implementation of this control technique is
complex thus requires fast processors such as DSPs.
5
motor can be performed because variable frequency AC supply can be generated using inverters.
However, since the switching frequency of an SCR was low which require commutation circuit in
order to turn-off, square wave inverters were mainly used in AC drive system. In early 1960s,
the improvement in the fabrication of BJT along with the introduction of pulse width modulation
(PWM) control technique has significantly contributed to the improvement in the AC motor
drives. Transient torque control to some extend was nearly achieved to the expense of a very
complex algorithm with numerous approximations. The true high performance torque control
similar to DC drives was still not achievable due to the complex magnetic coupling between
phases in the stator and rotor of the AC machines. Nevertheless, DC drives were gradually being
replaced with AC drives in medium performance variable speed applications. Applications
requiring precise and fast torque control were still dominated by DC drives.
The Newton’s Law states that, the net force acting on a body of mass M equals to the rate of
change of its mechanical momentum, which is the product of its mass and its velocity in the
direction of the net force. In the equation form, this is given by
(Mv ) dv dM
F=d =M +v (1)
dt dt dt
where F is the net force acting on the body, M is the mass of the body and v is its velocity. This
is illustrated by Figure 4.
x
v F = Fp − Ff
Fp dv
M Ff F=M
dt
dv
F=M
dt
For rotational motion (which is the case for rotating electrical machines), the force, the mass
and the linear velocity in translational motion are equivalent to the torque, the moment of
inertia and the angular velocity, respectively. Equation (1) can therefore be written as
6
(Jω) dω dJ
T=d =J +ω (3)
dt dt dt
where T is the net torque, J is the moment of inertia and ω is the angular velocity. The rotational
system which is analogous to the translational system of Figure 4 is shown in Figure 5.
θ
T = Te − Tl
TL
ω, Te
J dω
T=J
dt
dω
T=J (4)
dt
d 2θ (5)
T=J
dt 2
dω (6)
T = Te − Tl = J
dt
where Te is the internal electrical torque produced by the motor, Tl is the load torque and/or the
internal friction of the motor. T is the available torque at the shaft and is responsible for
accelerating the inertia of the motor. T is also known as the dynamic torque and it only exists
during the transient (i.e. acceleration and deceleration). In order to accelerate in forward
direction, Te –Tl must be positive; which means that the applied electrical torque must be larger
than the load torque. In order to decelerate, the net torque must be negative; the electrical
torque must be made smaller than the load torque and the motor operates in braking mode –
more on this later. Note that the speed is always continuous. A discontinuity in speed (i.e. step
change in speed) theoretically will require an infinite torque. This is analogous to the voltage and
current across a capacitor in which discontinuity in capacitor voltage is not allowed as it
correspond to an infinite capacitor current.
Equation (4) relates the torque and the mechanical speed (or position) of the machine. For a
given electrical torque profile, with the known moment of inertia and the load torque, the speed
profile of the drive system can be determined. In a torque-controlled drive system, the speed is
governed by the load. If the load torque comprise of only the frictional torque which is
proportional to the speed, (4) can be written as
dω (7)
Te = J + Bω
dt
Equation (7) can be easily simulated using SIMULINK as shown in Figure 6. In the simulation, a
square wave torque is applied.
7
10
torque
0
-10
tref 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
speed
To Workspace2
0
1 1
-K- pos
s s -200
Torque
Add 1/J Integrator Integrator1 To Workspace1 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
100
position
-K-
50
B
0
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
Usually in a cascaded closed-loop control system in which the speed is to be controlled, the
reference torque will be generated by the speed controller. In such cases, the torque will be
governed by the speed.
If we multiply (7) with the angular speed, we obtain an equation describing the power balance,
dω m (8)
ω m Te = ω m Tl + ω m J
dt
dω m
p D = p L + ωm J
dt
Where pD = ωmTe is the driving power, pL = ωmTl is the load power and ω m J dω m is the change in
dt
kinetic energy. Integrating the equation with time and setting the initial speed ω(0) = 0, we
obtain the following:
dω m
t t t
w D = ∫ p D dτ = ∫ p L dτ + ∫ ω m J dτ
0 0 0
dτ
ω
w D = w L + J ∫ ω m dω m
0
1
wD = wL + Jω2m
2 (9)
The last term of (9) is the stored kinetic energy of the system. It is analogous to the energy
2 2
stored in a capacitor ( 12 Cv ) or an inductor ( 12 Li ) . Similar to a capacitor voltage or an
inductor current, an angular velocity ω must be continuous. An abrupt (discontinuous) change
in ω will results in an infinite power.
8
ω Fl Fm
Tm
M
Tl r r
v
Figure 7 Translational and rotational motions
The relation between the torques and the linear forces are given by
Tl = rFl, Tm = rFm .
Also,
v = rω
dv Tm Tl d(rω)
Fm − Fl = M ⇒ − =M
dt r r dt
d(ω)
Tm − Tl = Mr 2 (10)
dt
Equation (10) states that the equivalent moment of inertia of the translational motion referred to
the axis of the pulley is given by Jequ = Mr2
ω1, Tm ω2
J2
Loss-free
J1 J3
gear
2r3
ω3
M3
The hoist drive system shown in Figure 8 can be represented by an equivalent system similar to
Figure 5. In order to do that, we need to obtain the equivalent moment of inertia and load
torque. If the mass M3 is considered being moved upwards, with the negligible frictional torque,
it can be shown that the torque equation for the equivalent system is given by
dω1 ω3 (11)
Tm = Je + r3 gM3
dt ω1
9
2 2
⎛ω ⎞ ⎛ω ⎞
where [
Je = J1 + ⎜⎜ 2 ⎟⎟ J2 + ⎜⎜ 3 ⎟⎟ J3 + M3 r32 ]
⎝ ω1 ⎠ ⎝ ω1 ⎠
v
X
2r m
belt
Roller
Gear
Motor
Figure 9 shows a belt conveyor drive system which is used to move load A which has a mass of
5 kg. Given that the frictional torque between the rollers and the belt is 25 Nm and the moment
of inertia of the rollers and motor are 250 × 10-3 kg-m2 and 300 × 10-3 kg-m2 respectively. The
radius of the roller is 0.2 m. The steady state speed of the motor is 1000 rpm and it is required
that the steady state speed of box A to be v = 3 m/s .
Solution
(i)
3 m/s Æ 15 rad/s. The speed of the shaft is 1000 rpm = 104.72 rad/s. Hence ratio n1/n2 =
0.1432
(ii)
Moment of inertia as seen by the motor’s shaft is due to the roller, load A and motor.
Jequ = 300 × 10-3 + (0.1432)2 (250 × 10-3 + 5 × 0.22) = 0.3644 kg-m2
(iii)
The load torque is due to the frictional torque of 25 Nm only.
Tequ = (0.1432)×25 = 3.58 Nm
(iv)
Using the equivalent rotating system,
Te = Tequ + Jequ (dω/dt) = 3.58 + 0.3644 (104.72/2) = 22.67 Nm
10
Synchronous motor Separately excited Induction motor Series DC motor
DC motor
The loads on the other hand will have their own T-ω characteristics. It is the intersection
between the motor and the load T-ω characteristics that determines the steady state speed. This
can be seen from (6) where at steady state dω/dt = 0 and Te = Tl.
The steady state torque-speed characteristic of the motor depends on the applied voltage or
current. Hence, by changing the point of intersections between the motor and load torque-speed
curves, different steady-state speeds can be achieved (Figure 11).
Torque-speed characteristic of
the load, Tl
ω1 ω2 ω3 speed
Different motor
speeds
Figure 11 Different steady state speeds (Tl = Te) for different motor’s T-ω characteristics
It should be noted that the graph in Figure 11 only displayed the steady state characteristics of
the load and motor. The transient responses before these steady state speeds are reached have
to be dealt with using the dynamic characteristics of the load and motor.
11
Frictional torque
Moving parts of the motor and load constitute the frictional torque. There are several types of
frictional as described in Figure 12 and explained below:
In practical drive system consisting of load and motor, all components of friction described
above exist simultaneously. However, in most of the cases, only one or two components are
dominating. For instance, a fan or a propeller will typically have the windage friction
dominating, whereas in paper mill and machine tools, the dominating one could be the viscous
friction.
Coulomb
ω
Windage
Figure 12 Frictional torque
Viscous
Speed Gravitational
torque Te
TL = rFL = r g M sin α
TL
Torque gM
α
FL
12
Some examples of load torques
a. Load torques which are independent of the speed
Typical example would be the load caused by gravitational pull. The load does not
change sign even when the direction of motion changes.
b. Torques which are dependent on speed
- Proportional to the speed – e.g. load torque due to the laminar flow of the lubricant
known as viscous friction
- Proportional to the square of the speed – e.g. fan, blowers and pumps where
turbulent flow of liquid or air occurs.
- Inversely proportional to the speed – this type of load consumes constant power.
Large torque required at low speed and small torqued required at high speed. E.g.
coiler used in steel strip or paper mills.
Thermal considerations
The losses in the machines contribute to the temperature increase in the machine. The various
parts of the machine have different temperature limits. Particularly important is the insulation
used for the windings which give rise to the different classes of machines. If the temperature
goes beyond the allowable temperature, it will cause an immediate breakdown (short circuit in
the winding) or it will deteriorate the quality and hence reduces the lifetime of the insulation
material. Allowable power losses are higher for materials which can withstand higher
temperature which translates to higher costs. The classes of the insulator used for the winding
in electrical machines are shown in Table 1.
Core losses
Mainly due to eddy current and hysteresis losses
The constructions of the machines are very complex; normally built from various types of
materials (heterogeneous) with complex geometrical shapes. To exactly predict the heat flow and
hence the temperature distribution is extremely difficult. Based on the assumptions that the
temperature limits of all parts does not exceed the temperature limits under certain operating
conditions, the motors can therefore adequately modeled as homogeneous bodies. Obviously,
this assumption cannot determine the specific internal thermal conditions for the motors.
13
Thermal capacity, C (Ws/oC)
Surface A, (m2)
Surface temperature, T (oC)
Ambient temperature, To
p1 p2
INPUT POWER OUTPUT POWER
(losses) (convection)
Let us assume that a homogeneous body shown in Figure 14 represents a motor which has a
thermal capacity C. The input power, which is the losses incurred in the motor, is represented
by p1 whereas the output power, which is the power released as heat by convection, is
represented by p2. The output power due to radiation is assumed negligible because of the low
operating temperature and back radiation. Under a steady state condition, the input power
equals the output power; this is when the steady state temperature is reached. The equation
describing the power balance is given by
dT
C = p1 − p2 (12)
dt
dΔT
C + αA(ΔT ) = p1
dt
or
dΔT p (14)
τT + (ΔT ) = 1
dt αA
where τT = C/(αA) is the thermal time constant. With ΔT(0)=0 and a step change in the power
input p1 from 0 to ph at t=0, the solution for ΔT is
ΔT =
ph
αA
(
1 − e −t / τ ) (15)
During cooling, i.e. when heat is removed at t=0, the temperature of the body decays to the
ambient temperature.
(16)
ΔT = ΔT(0) ⋅ e − t / τ
14
ph
ΔT αA
Heating
transient
τ t
ΔT
ΔT(0 ) Cooling
transient
τ t
If the thermal time constant is large, a temporary overload is therefore possible without
exceeding the temperature limits. Three typical modes of operation are:
- Continuous duty
- Short time intermittent duty
- Periodic intermittent duty
15
depends on the duty cycle of the load. The heating and cooling time constant may be different
depending whether the machine is self-cooled or forced-cooled.
The ω–T plane with motor’s shaft cross sectional area is shown in Figure 16. The positive or
forward speed is arbitrarily chosen in counterclockwise direction (it can also be chosen as
clockwise). The positive torque is in the direction that will produce acceleration in forward
speed, as shown in the figure.
The plane is divided into 4 quadrants , thus 4 modes of operation. The quadrants are marked as
I, II, III and IV
ω
Te
Te
ω ω
II I
T
Te III IV
Te
ω ω
Quadrant I
Both torque and speed are positive – the motor rotates in forward direction, which is in the same
direction as the motor torque. The power of the motor is the product of the speed and torque (P
= Teω), therefore the power of the motor is positive. Energy is converted from electrical form to
mechanical form, which is used to rotate the motor. The mode of operation is known as forward
motoring.
Quadrant II
The speed is in forward direction but the motor torque is in opposite direction or negative value.
The torque produced by the motor is used to ‘brake’ the forward rotation of the motor. The
mechanical energy during the braking, is converted to electrical energy – thus the flow of energy
is from the mechanical system to the electrical system. The product of the torque and speed is
negative thus the power is negative, implying that the motor operates in braking mode. The
mode of operation is known as forward braking.
Quadrant III
The speed and the torque of the motor are in the same direction but are both negative. The
reverse electrical torque is used to rotate the motor in reverse direction. The power, i.e. the
product of the torque and speed, is positive implying that the motor operates in motoring mode.
The energy is converted from electrical form to mechanical form. This mode of operation is
known as reverse motoring.
16
Quadrant IV
The speed is in reverse direction but the torque is positive. The motor torque is used to ‘brake’
the reverse rotation of the motor. The mechanical energy gained during the braking is converted
to electrical form – thus power flow from the mechanical system to the electrical system. The
product of the speed and torque is negative implying that the motor operates in braking mode.
This mode of operation is known as reverse braking.
200
100
speed (rad/s)
-100
-200
0.19 0.2 0.21 0.22 0.23 0.24 0.25
20
15
torque (Nm)
10
0
0.19 0.2 0.21 0.22 0.23 0.24 0.25
In most cases, the torque during this transient condition can be up to 3 times the rated torque
of the motor (for servo motor, it can be as high as 8 to 10 times the rated value). This
momentary high torque is possible due to the large thermal capacity of the motor with suitable
insulators used for the winding. The converter, which conducts the motor current, must be able
to sustain this condition. However since the thermal capacity of the converters (i.e. switching
devices) is small, the current cannot be higher than its rated value even for a short time.
Consequently, the current rating of the converter is normally set to equal the maximum
allowable motor current and this can be as high as the 3 times the motor rated current. The
maximum allowable torque during transient of a drive system is determined by the current
rating of the converter used whereas the continuous torque limit depends on the current rating
of the motor. The operating area of a 4-quadrant motor drive is shown in Figure 18. The
converter is normally protected from the over-current condition by the current limiter
mechanism within the converter system, which means that sustained overloads on the motor
has to be protected by an additional thermal protection mechanism. Above the base speed, ωb,
the toque is limited by the maximum allowable power, which depends on whether the transient
or continuous torque limit is considered. The speed limit basically depends on the mechanical
limitation of the motor.
17
Torque
Transient
Power limit for
torque limit
transient torque
Continuous
torque limit Power limit for
continuous
torque Figure 18 Limits for torque,
speed and power for drive system
Maximum
speed limit
- ωb ωb
Speed
Steady-state stability
The motor will operate at the steady-state speed (point where Tl = Te) provided that the speed is
of stable equilibrium. The stable equilibrium speed is investigated using steady-state torque-
speed characteristics of the load and motor.
A disturbance in any part of the drive will result in a speed to depart from the steady state
speed. However, if the steady-state speed is of stable equilibrium, the speed will return to the
stable equilibrium speed. On the other hand, if the speed is not of the stable equilibrium, the
disturbance will results in the speed to drift away from the equilibrium speed. It can be shown
that the condition for stable equilibrium is:
dTl dTe
− >0 (17)
dω dω
Torque
Torque
Te Tl
Tl Te
Tln Te2
Q1 Q2
Ten Tl2
Δω
Δω
ω1 speed ω2
speed