DATASHEET

Modbus TCP/IP
Communication Module for
CompactLogix®
MVI69-MNET

The inRAx Modbus TCP/IP Communication Module is designed to allow


CompactLogix® /MicroLogix® processors to interface with other Modbus
TCP/IP protocol-compatible devices, including not only Modicon®
processors, but also a wide variety of other Client and server devices.

The MVI69-MNET module is a single-slot solution that provides a


powerful connection between Rockwell Automation® CompactLogix
processors and Modbus TCP/IP network applications. The Modbus
TCP/IP network applications include those networks hosted by Modicon
Quantum processors, networks controlled by operator interface software
applications, and the growing number of manufactured devices that
support this protocol.

The module acts as an input/output module between the Modbus TCP/IP


network and the CompactLogix backplane. The data transfer from the
processor is asynchronous from the actions on the Modbus TCP/IP
network. A 5000 16-bit register data space in the module exchanges data
between the processor and the Modbus TCP/IP network.

Features

 Support for the storage and transfer of up to 5000 registers to/from the PLC processor using the block transfer interface
 User-definable module memory usage
 10/100 Base-T Ethernet-compatible interface
 All data mapping begins at Modbus register 40001
 Configurable parameters for the Client, including a minimum response delay of 0 to 65535 milliseconds

®
Floating-point support for Enron, Daniels , and other floating-point data types
 Single-Slot, 1769 backplane-compatible
 The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor
and module.
 Ladder Logic is used for data transfer between module and processor. Sample ladder file included.
 Configuration data obtained from configuration text file downloaded to module. Sample configuration file included.
 Supports all CompactLogix and MicroLogix 1500 LRP Controllers except 1769-QBFC1B, 1769-L16x, and 1769-L18x.
Modbus TCP/IP Server Protocol Specifications
The server driver supports connections to up to five Modbus TCP/IP Clients using
Service Port 502 with standard MBAP messaging, and up to five Clients using Modbus
RTU/ASCII on Service Port 2000 (and others).

Modbus TCP/IP Client Protocol Specifications


The Client driver supports the active reading and writing of data with Modbus TCP/IP
compatible devices.
This one Client supports up to 100 commands, which can be addressed to one or more Where Automation
servers. Connects™
Status Data
Communication error codes, success-fail counters, and port states are available, as well Additional Products
as module diagnostic data. ®
ProSoft Technology offers a full
complement of hardware and
Hardware Specifications software solutions for a wide variety
of industrial communication
Specification Description platforms. For a complete list of
Dimensions Standard 1769 single-slot module products, visit our web site at:
Current Load 800 mA max @ 5 VDC www.prosoft-technology.com
Power supply distance rating of 2 (L43 and L45
installations on first 2 slots of 1769 bus)
Operating Temp. 0°C to 60°C (32°F to 140°F)
Storage Temp. -40°C to 85°C (-40°F to 185°F)
Relative Humidity 5% to 95% (with no condensation)
LED Indicators Power and Module Status
Ordering Information
Application Status To order this product, please use the
CFG Port Activity following:
Ethernet Port Activity
Error Status
CFG Port (CFG) RJ45 (DB-9M with supplied cable) Modbus TCP/IP
RS-232 only Communication
No hardware handshaking
App Port (Ethernet modules) 10/100 Base-T Ethernet compatible interface Module for
Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz CompactLogix®
for 60 s, applied as specified in section 5.3.2 of
IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than MVI69-MNET
or equal to 5000 [ARP] frames-per-second and
less than or equal to 5 minutes duration To place an order, please contact
Shipped with Unit RJ45 to DB-9M cables for each port your local ProSoft Technology
6-foot RS-232 configuration cable distributor. For a list of ProSoft
Technology distributors near you,
go to:
www.prosoft-technology.com
and select Where to Buy from the
menu.

Copyright © 2014 ProSoft Technology, Inc. All rights


reserved. 10/2/2014

Specifications subject to change without notice.