PARTS SERVICE
LD056 (E)
See list with
affected models
GRAM August 2014
SUBJECT: CDF Load Tool
Models affected: R1.4-2.5, R1.6N, R1.6-2.0HD (D435)
Reason: Explanation of configuration file upload with CDF Load Tool
Technical Description:
Download the TOOL CONFIG. FILE UPLOADER from Hypass Online:
Prerequisites:
Windows XP 32-64 bit, Windows 7 32-64 bit
IFAK driver: avilable in software section of D435 on Hypass Online.
Installation:
• Create a directory on C: named c:\cdf_program
• Create a directory on C: named c:\temp_cdf
• Extract files from zip into c:\cdf_program
Directory c:\cdf_program should contains these three files:
1. ZAPI.EXE
2. cdf_upload_tool.exe
3. CDF Load Program_documentation.docx
INTERCHANGEABILITY: N/A
PARTS STOCK: N/A
EFFECTIVE SERIAL NUMBER: N/A
Page 1 of 4 DCN 25124 Rev. 04
We reserve the right to make changes in design or add improvements without incurring the obligation to make such changes in equipment
previously manufactured. The content of this publication is for information only and will not be considered for warranty reimbursement.
Use:
• Copy CDF file downloaded from TRD into c:\temp_cdf.
• Connect IFAK Dongle to truck (X40).
• Launch c:\cdf_program\cdf_upload_tool.exe.
• Into the form , insert Serial Number and press Enter (Figure 1).
Figure 1
The software will search the CDF file in c:\temp_cdf (D435T01401L_01.txt in this example).
If it founds it, the CHK button will be enabled (Figure 2).
Figure 2
Click CHK button to continue.
Page 2 of 4 LD056R00EHE DCN 25124 Rev.04
We reserve the right to make changes in design or add improvements without incurring the obligation to make such changes in equipment
previously manufactured. The content of this publication is for information only and will not be considered for warranty reimbursement.
After that the software will check CDF syntax and CAN communication.
Figure 3
If check is OK, button GO will be enabled (Figure 4).
Figure 4
Press GO to start upload CDF on truck.
Page 3 of 4 LD056R00EHE DCN 25124 Rev.04
We reserve the right to make changes in design or add improvements without incurring the obligation to make such changes in equipment
previously manufactured. The content of this publication is for information only and will not be considered for warranty reimbursement.
If the upload is successful, the program will reset: the serial number field will be empty and the
buttons will be disabled (Figure 5).
Figure 5
Error list and and fix:
Error Code Error description Fix
No user action, contact PSG
1 Wrong parameter
Warehouse
No user action, contact PSG
2 CDF not found
Warehouse
Corrupted CDF, contact PSG
3 CheckSum error
Warehouse
4 IFAK wrong configuration Check IFAK configuration and retry
Check CANBUS connection, switch
5 CANBUS wrong configuration
On truck
Check CANBUS connection, switch
6 CAN Master set communication error
ON truck
7/8/9 Upload CDF error Contact PSG Warehouse
CDF created for another truck,
100 Serial Number mismatch
forbidden upload.
SW versions on truck not valid for Verify SW version on truck, contact
200
CDF PSG Warehouse
211 Missing parameters Contact PSG Warehouse
Page 4 of 4 LD056R00EHE DCN 25124 Rev.04
We reserve the right to make changes in design or add improvements without incurring the obligation to make such changes in equipment
previously manufactured. The content of this publication is for information only and will not be considered for warranty reimbursement.