0% found this document useful (0 votes)
399 views5 pages

ESPRIT 747 - Programare

This document provides a 3-sentence summary of the key programming details for an alarm panel: The document outlines the programming details for various alarm panel settings including installer codes, user codes, zone and reporting codes, telephone numbers, and output programming. Default codes are provided to reset the panel programming. Version 2.0 of the software includes changes from the previous version 1.3.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
399 views5 pages

ESPRIT 747 - Programare

This document provides a 3-sentence summary of the key programming details for an alarm panel: The document outlines the programming details for various alarm panel settings including installer codes, user codes, zone and reporting codes, telephone numbers, and output programming. Default codes are provided to reset the panel programming. Version 2.0 of the software includes changes from the previous version 1.3.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

QS747-950222

SOFTWARE VERSION 2.0 IMPORTANT See last page for changes from VERSION 1.3

To enter programming, press [ENTER] + installer code (Installer default code 747474)

ADDRESSES: addresses "000" to "255" ( key [10] = 0)

HEXA VALUE DISPLAY


Value of 2NDdigit = 10
( 8 + 2 = 10)
Value of 1ST digit = 3
( 2 + 1 = 3)
(8) (4) (2) (1) VALUE = "30"
No display = SKIP (empty)
10 = [0] = [A]

INSTALLER CODE LOCK ([1][4][7] = Installer code locked, any other combination = Installer code unlocked) (default code unlocked)
255: __/__

PANEL IDENTIFIER FOR UPLOAD/DOWNLOAD 00 - [F][F] ([10] = 0) (default code (empty) -"SKIP")
001: __/__ 002: __/__

PC UPLOAD/DOWNLOAD PASSWORD 00 - [F][F] ([10] = 0) (default code (empty) -"SKIP")


003: __/__ 004: __/__

ACCESS CODES:
INSTALLER'S CODE: Full access to programming,(all addresses except 008-067). (default / reset code 747474)
No access to arming/disarming and access code programming (can be used to modify installer code)
005: __/__ 006: __/__ 007: __/__

PROGRAMMING MASTER AND USER CODES:

[ENTER] + master code + code number (2 digit) + new code (4 or 6 digit) + [ENTER]

MASTER CODE = 00 ([10][10]) (default / reset code 474747)

USER CODES 01-06 = Bypass, Away, Stay, Arm, Disarm

USER CODES 07-18 = Arm, Disarm

USER CODES 19 = Arm ONLY

REPORTING CODE: (all digits from [1]-[F] are valid / [2ND] = SKIP = code is not reported) (default code "SKIP, SKIP" [2ND][2ND])
If a condition should not be reported, enter [2ND][2ND] after the required address.
"TROUBLE REPORT" CODES: "RESTORATION" CODES: "SPECIAL REPORT" CODES:

069: __/__ Fire loop trouble 070: __/__ Fire loop trouble 084: __/__ Panic 1
071: __/__ No AC / low AC 077: __/__ No AC / low AC 085: __/__ Panic 2
072: __/__ Battery disconnected/low voltage 078: __/__ Battery disconnect/low voltage 086: __/__ Panic 3
073: __/__ Maximum auxiliary current 079: __/__ Maximum auxiliary current 087: __/__ Partial arming
074: __/__ Bell disconnect/max. bell current 080: __/__ Bell disconnect/max. bell current 088: __/__ Test report
075: __/__ Tamper / wiring 081: __/__ Tamper / wiring
076: __/__ Timer loss 082: __/__ Timer loss
083: __/__ Telephone line
-1-
QS747-950222
-2-
SYSTEM "A" (ZONES 1-12) (default code "SKIP, SKIP" [2ND][2ND]) SYSTEM "B" (EXTENSION 1-12) (default code "SKIP, SKIP" [2ND][2ND])
ALARM REPORT CODES: ZONE RESTORATION CODES: ALARM REPORT CODES: ZONE RESTORATION CODES:
089: __/__ Zone 1A 101: __/__ Zone 1A 137: __/__ Zone 1B 149: __/__ Zone 1B
090: __/__ Zone 2A 102: __/__ Zone 2A 138: __/__ Zone 2B 150: __/__ Zone 2B
091: __/__ Zone 3A 103: __/__ Zone 3A 139: __/__ Zone 3B 151: __/__ Zone 3B
092: __/__ Zone 4A 104: __/__ Zone 4A 140: __/__ Zone 4B 152: __/__ Zone 4B
093: __/__ Zone 5A 105: __/__ Zone 5A 141: __/__ Zone 5B 153: __/__ Zone 5B
094: __/__ Zone 6A 106: __/__ Zone 6A 142: __/__ Zone 6B 154: __/__ Zone 6B
095: __/__ Zone 7A 107: __/__ Zone 7A 143: __/__ Zone 7B 155: __/__ Zone 7B
096: __/__ Zone 8A 108: __/__ Zone 8A 144: __/__ Zone 8B 156: __/__ Zone 8B
097: __/__ Zone 9A 109: __/__ Zone 9A 145: __/__ Zone 9B 157: __/__ Zone 9B
098: __/__ Zone 10A 110: __/__ Zone 10A 146: __/__ Zone 10B 158: __/__ Zone 10B
099: __/__ Zone 11A 111: __/__ Zone 11A 147: __/__ Zone 11B 159: __/__ Zone 11B
100: __/__ Zone 12A 112: __/__ Zone 12A 148: __/__ Zone 12B 160: __/__ Zone 12B

ARMING REPORT CODES: DISARMING REPORT CODES: ARMING REPORT CODES: DISARMING REPORT CODES:
113: __/__ Espload 125: __/__ Espload 161: __/__ User code 11 170: __/__ User code 11
114: __/__ Master code 126: __/__ Master code 162: __/__ User code 12 171: __/__ User code 12
115: __/__ User code 1 127: __/__ User code 1 163: __/__ User code 13 172: __/__ User code 13
116: __/__ User code 2 128: __/__ User code 2 164: __/__ User code 14 173: __/__ User code 14
117: __/__ User code 3 129: __/__ User code 3 165: __/__ User code 15 174: __/__ User code 15
118: __/__ User code 4 130: __/__ User code 4 166: __/__ User code 16 175: __/__ User code 16
119: __/__ User code 5 131: __/__ User code 5 167: __/__ User code 17 176: __/__ User code 17
120: __/__ User code 6 132: __/__ User code 6 168: __/__ User code 18 177: __/__ User code 18
121: __/__ User code 7 133: __/__ User code 7 169: __/__ User code 19
122: __/__ User code 8 134: __/__ User code 8
123: __/__ User code 9 135: __/__ User code 9
124: __/__ User code 10 136: __/__ User code 10
Enter [2ND][2ND] if no report code is required.

ACCOUNT NUMBERS:
[ENTER] + Installer code + [9] + 8 digit of the two system account numbers + [ENTER] __ / __ / __ / __ / __ / __ / __ / __
A / B
OR SYSTEM "A" ACCOUNT NUMBER: SYSTEM "B" ACCOUNT NUMBER:
202: __/__ 203: __/__ 204: __/__ 205: __/__
(valid digits are [1]-[F] / [2ND] = SKIP) (default code [2ND][2ND][2ND][2ND]) If only one account number is required, the same code should be entered
for both System A and System B.

PROGRAMMABLE OUTPUT 1*: PROGRAMMABLE OUTPUT 2*:


208: __/__ 210: __/__ 209: __/__ 211: __/__
*To follow smoke detector reset program: PGM 1: 208: [BYP]/[1] 210: [2]/[2ND] PGM 2: 209: [BYP]/[1] 211: [2]/[2ND]

COMMUNICATOR FORMATS (see page 4 "TABLE 1") TELEPHONE KEY PROGRAMMING


(default code [2ND][2ND])
st
206: __/__ 1 digit: "telephone number 1" format
nd
2 digit: "telephone number 2" format

TELEPHONE NUMBER PROGRAMMING:


(default = [2ND][2ND])
If only one central station phone number is available, the same telephone Switch from
number should be programmed for telephone number 1 and 2. pulse to tone

PC DOWNLOAD TELEPHONE NUMBER:


[ENTER] + Installer code + [3] + up to first 8 digits (including last digit "end of number" [TRBL]) + [ENTER], for the next 8 digits same but enter [4]
instead of [3].
OR
178: __/__ 179: __/__ 180: __/__ 181: __/__ 182: __/__ 183: __/__ 184: __/__ 185: __/__

CENTRAL STATION TELEPHONE NUMBER 1:


[ENTER] + Installer code + [5] + up to first 8 digits (including last digit "end of number" [TRBL]) + [ENTER], for the next 8 digits same but enter [6]
instead of [5].
OR
186: __/__ 187: __/__ 188: __/__ 189: __/__ 190: __/__ 191: __/__ 192: __/__ 193: __/__

CENTRAL STATION TELEPHONE NUMBER 2:


[ENTER] + Installer code + [7] + up to first 8 digits (including last digit "end of number" [TRBL]) + [ENTER], for the next 8 digits same but enter [8]
instead of [7].
OR
194: __/__ 195: __/__ 196: __/__ 197: __/__ 198: __/__ 199: __/__ 200: __/__ 201: __/__
-2-
-3- QS747-950515

AUTO REPORTING TIME: (create test report code at address 088). To reset real time clock, press [ENTER] + Master or Installer code + [MEM]

209: __/__
ADDRESS 209: 2ND DIGIT PROGRAMMING
ST
If difference in hours between 2ND digit
ADDRESS 209: 1 DIGIT PROGRAMMING current time and desired reporting time
Numbers of days If difference between current time and desired reporting time 1 or 13 [1]
between reports LESS THEN[1] 12H MORE THEN 12H 2 or 14 [2]
1 [2] [9] 3 or 15 [3]
2 [3] [10] 4 or 16 [4]
3 5 or 17 [5]
4 [4] [11]
6 or 18 [6]
5 [5] [12] 7 or 19 [7]
6 [6] [BYP] 8 or 20 [8]
7 9 or 21 [9]
[7] [MEM]
8 10 or 22 [10]
[TRBL] 11 or 23 [11]
12 or 24 [12]
To desable auto reporting, enter "FF" ([TRBL][TRBL])

PANEL OPTIONS: (default = "OFF")

214: KEY 216: KEY


OFF / ON OFF / ON
Telephone line monitor disabled 1 enabled Panic 1 disabled 1 enabled (Keys [1] & [3])
TLM trouble only 2 TLM trouble activates alarm Panic 2 disabled 2 enabled (Keys [4] & [6])
Auto zone shut down disabled 3 enabled Fire panic 3 disabled 3 enabled (Keys [7] & [9])
Call back disabled 4 enabled Panic 1 silent 4 audible
Reporting disabled 5 enabled Panic 2 silent 5 audible
PS1/Key switch disabled 6 enabled Panic 3 silent 6 fire
Pulse dialing 7 Tone dialing (DTMF) 6 digit access codes 7 4 digit
(handshake) 1400 Hz 8 2300 Hz Key [10] fast arm disabled 8 enabled
(BPS) "REPORTING
10 bps 9 20 bps See "Table 1" Fast arm = regular arm 9 = stay arm (Key [10], keyswitch)
FORMAT OPTIONS"
page 4
(Data) 1800 Hz 10 1900 Hz "TAMPER / ZONE WIRE 10 See "Table 2"
DEFINITION" page 4
Answering machine override disabled 11 enabled 11
Auto reporting (days X 1) 12 (days X 4) 12 zone system 12 24 zone

ZONE DEFINITION: (default = "OFF")


218 220
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 11B 12B
Slow = ON
Fast = OFF

222 224
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 11B 12B
Silent = ON
Audible = OFF

226 228
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 11B 12B
Fire = ON
Burglary = OFF

230 232
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 11B 12B
24 Hr. = ON
Regular = OFF

234 236
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 11B 12B
Instant = ON
Delay = OFF

238 240
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 11B 12B
Follow = ON
Delay = OFF

242 244
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 11B 12B
Stay = ON
Regular = OFF

246 248
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 11B 12B
Bypass enabled = ON
Bypass disabled = OFF
-3-
QS747-950222
-4-
3 DIGIT DECIMAL PROGRAMMING (values entered at addresses [250] - [255] contain 3 digits between "000" and "255") ([10]/[2ND] = 0)
248: __/__/__ (seconds) Exit delay (default 60 seconds)
DECIMAL VALUE DISPLAY
249: __/__/__ (seconds) Entry delay 1 (default 45 seconds) (8) (4) (2) (1)
Total value (57)
250: __/__/__ (seconds) Entry delay 2* (default 45 seconds)
( 8 + 1 + 32 + 16 = 57)
251: __/__/__ (minutes) Bell cut-off time (default 5 minutes)
(128) (64) (32) (16)
252: __/__/__ ( x 3 mSec.) Slow zone speed (default 500 mSec.) No light = 0

253: __/__/__ Number of rings before answer (default 8 rings, enter "000" panel will not answer)
(Unless answering machine override is disabled, the panel will answer for answering machine
dialing procedure)

254: __/__/__ (minutes) AC report delay

255: __/__/__ Installer code lock (147 = locked) (default unlocked)

*Entry delay 2 is programmable at zones 3A, 9A, 3B and 9B.

KEYPAD TROUBLE DISPLAY COMMUNICATOR FORMAT (TABLE 1)

KEY
Key "ON" =
[2ND] = ADEMCO slow (1400Hz, 1900Hz, 10bps)
[1] No battery/low battery [7] Communicator report failure [1] = unused
[3] AC failure [8] Timer loss [2] = SILENT KNIGHT fast (1400Hz, 1900Hz, 20bps)
[4] Bell disconnect [9] Tamper or zone wiring failure [3] = SESCOA (2300Hz, 1800Hz, 20bps)
[5] Maximum bell current [10] Telephone line failure [4] = RADIONICS (40bps with 1400Hz handshake)
[6] Max auxiliary current [11] Fire loop trouble [5] = RADIONICS (40bps with 2300Hz handshake)
[6] = RADIONICS with PARITY (1400Hz, 40bps)
[7] = RADIONICS with PARITY (2300Hz, 40bps)

(TABLE 2)

1 EOL-

2 EOL- Silent alarm and trouble codes reported*


Audible alarm and trouble codes reported**

** Silent zones will generate a silent alarm

NOTES:
Initiating test report; Press [ENTER] + installer or master code + [BYP]
Address 214, key [5] "ON", Report code at address 088, telephone number at address 189-204, and account number (s) at address 205-208 must be
programmed.

Initiating Call to Espload via telephone; Press [ENTER] + installer or master code + [TRBL]
Panel and PC ID numbers, (address 001-004, and PC download telephone number (address 181-188) must be programmed)

Initiating call to Espload via 747ADP-1; Press [ENTER] + installer or master code + [AWAY] (In Espload, activate "blind dial" in modem
setup.) (Direct PC modem and panel connection.) Note: The panel must be connected to a battery.

To reset timer; Press [ENTER] + installer or master code + [MEM]

To stop communication attempts;


Disable reporting at address 214, key [5] "OFF", then press [ENTER] + installer or master code + [STAY]

Reset to default;
Reset jumper "ON", [ENTER] + installer or master code + [STAY], then remove reset jumper

When communicating with Espload it is not possible to enter programming mode. All other functions are accessible.

For technical support please fax your name, country, fax and phone numbers in English/ French to (514) 491- 3284. We will do our best to respond
within 24 hrs.

-4-
QS747-950222
-5-
ZONE DESCRIPTION:
Zone 1A: Zone 1B:
Zone 2A: Zone 2B:
Zone 3A: Zone 3B:
Zone 4A: Zone 4B:
Zone 5A: Zone 5B:
Zone 6A: Zone 6B:
Zone 7A: Zone 7B:
Zone 8A: Zone 8B:
Zone 9A: Zone 9B:
Zone 10A: Zone 10B:
Zone 11A: Zone 11B:
Zone 12A: Zone 12B:

Version 2.0 modifications from version 1.3.


Important Note: This software version is not compatible with previous hardware versions.

1) Only zone A12 (when programmed "24 hour") can be defined as a "fire" zone.
The fire zone functions as an N.O. loop with 1 EOL resistor. Fire loop trouble is reported if loop is open.
2) All zones can be individually programmed "delay 1" or "delay 2".
3) The keyswitch and key [10] can be individually programmed for "stay" arming or regular arming.
4) "AC trouble" report delay is programmable.
5) The installer code can be locked by programming [1][4][7] at address 255.
6) Four new format options for the communicator (RADIONICS) can be programmed individually
for each of the two central station telephone numbers.
7) A serial output option is now available.
8) User code 19 is now "arm only".
User code 20 has been deleted.
9) The "special report" code for "disarm after alarm" has been deleted.
"Disarm" report can be programmed to "always" report or only "report after alarm".
10) "NC loops" mode for zone loops.
11) Pulse dial mode selections: EUROPE (1:2), USA (1:1.5).
12) Zone restoration reports can be sent on zone closure or upon bell cut-off.

WARRANTY
Warranty conditions for the Esprit 747 may vary from country to country. Please consult your local dealer for com-
plete warranty information. In all cases, the warranty does not cover malfunctions arising from installer error or fail-
ure to follow installation/operation instructions, nor does it apply to damages due to causes beyond the control of
Paradox Security Systems Ltd., such as lightning, excessive voltage, mechanical shock or water damage.

LIABILITY
Under no circumstances shall Paradox Security Systems Ltd. be held liable for any direct or indirect damages, loss
of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, instal-
lation, operation or failure of this product.

WARNING
This security system should undergo frequent testing. However, despite regular testing, and due to, but not lim-
ited to, criminal tampering or electrical disruption, it is possible for this product to fail to perform as expected.

Technical Support Fax: (514) 491-3284 USA technical support: LITTON - 1 (800) 336-5917
PARADOX SECURITY SYSTEMS LTD. Fax: (514) 491-2313 Canada technical support: MSP - 1 (800) 361-2615
780 Industrial Blvd, St Eustache, Quebec, Canada J7R 5V3 9412-011

-5-

You might also like