Thermax

A Chart Industries Company


Product Datasheet 5.1
TVN Series Trim and Pressure Build Vaporizers
Direct Steam Trim Heaters, Vaporizers and Pressure Build Units for Cryogenic
and Liquefied Gases with Thermax In-Tube Vortex Generators for Low Surge
Performance.

Description Pressure Gage 0-300

Thermax TVN automatic trim heaters and pressure Pressure Relief Valve
build units are fully engineered and assembled Steam Inlet Regulator
units. The main components are:
Liquid Outlet 3/4” NPT
1. Vertical or horizontal steam chamber.
Liquid Inlet 3/4” NPT
2. Process coil or tube bundle consisting of 18
BWG stainless steel tubes standard.
3. Standard temperature regulator on inlet steam Plan View
line.
4. Optional temperature regulator on inlet stea
line with a gas discharge temperature controller
connected to a pneumatic steam valve.
Pressure Gage 0-300

TVN Series Trim and Pressure Build Vaporizers


5. Condensate trap assembly.
6. Computerized full ASME VIII Div. 1 code design Pressure Relief Valve
as standard. Steam Inlet Regulator
7. CRN. Stoomwezen, CUAA, TUV. Australian and Vacuum Breaker
other design approvals available.

Operating Principle
Liquefied or cold gas entering the tube bundle is
heated or vaporized and is super heated by the
Outlet 3/4” NPT
steam condensing in the steam chamber. The stan-
dard unit with steam pressure regulator allows steam Cryogenic Vaporizing
Tubing
into the chamber on falling steam pressure. On
Inlet 3/4” NPT
optional temperature controlled units, the warm gas
leaving the unit activates the controller, which in 1” Insulation with
Aluminum Jacket
turn, throttles the steam valve. Final gas temperature
is determined by the steam pressure the controller
and valve maintain in the steam chest. The conden-
Steam Trap Conden-
sate trap drains spent steam from the chest, while sate Outlet Drain to
holding the steam under pressure within the chest. Gravity
Temperature control can also be achieved by using a
self activating temperature regulator in lieu of the
pressure regulator on the pneumatic valve. Accurate
temperature control can be attained with Thermax
3-way mixing Thermavalve.

Elevation View

Thermax www. chartindustries.com www.thermaxinc.com Tel. 508-999-1231


V aporizers Heat Exchangers Thermal Systems Cr yogenic Equipment
Steam Trim Heaters and Controls & Steam Trim:
Thermax PRESSURE BUILD units can be designed
Pressure Build Units
Approx. range. Thermax vaporizers feature Vortex Flows
Approx.
Ratings Dim., Vert. action tubes for smooth, high performance which
Model Weight
MSCFH Dia. x H.
(lbs.)
(inches) Thermax vortex action greatly increases the unit
TC 5 5 10 x 52 250 over-all performance and permits surge free opera-
tion in the most common installations. In addition,
TC 10 10 12 x 60 325 each automatic vaporization unit is normally
TC 15 15 14 x 72 400 equipped with:
TC 20 20 14 x 72 450
1. Steam strainer
TC 25 25 14 x 72 500 2. Oversize thermostatic main condensate trap
TC 30 30 14 x 76 525 3. Shell relief valve
4. Weatherproof shell insulation, complete with
TC 35 35 14 x 76 550 aluminum or PVC outer jacket weather guard
TC 40 40 16 x 76 575
TC 45 45 16 x 80 650
1. All pneumatic control valve and temperature
TC 55 55 16 x 80 700 sensor
2. Pneumatic supply pressure regulator
3. Steam line drip trap
4. Block and bypass valving
5. Pressure gauges

Optional
Block & Optional
Valve Pressure
Valve

Optional Option - Trim Heater Coil


Block & al Relief or Pressure
Steam
Valve Valve Build Vaporizer
Strainer
Gas
Out
Pressure
Condensate Regulator
Drip Trap Vacuum
Breaker
Steam
Inlet Cryo -
gen In Conden -
Flow Diagram, Direct Steam sate Outlet

NOTE: Units In this “Process Coil” are also available All tables shown on this Datasheet are intended as a guide that
with Steam Sparged Water Bath controls. The water reflect our experience on these models. Actual performance may
vary. Please call Thermax Inc. for specific applications. This
bath option makes reduced "MAX OUT" gas tem - product and/or data was designed and/or developed by
peratures possible by using 100-120°F bath design Thermax Inc. and shall not be used in any way injurious to the
temperature. interests of Thermax Inc.
Contact Thermax for datails. See datasheet 6.0

+1 508 999 1231


[email protected]
© Chart Inc.
540 Hawthorn St. ∙ Dartmouth, MA 02747 USA www.thermaxinc.com T1215 PN 20988988