Waterwise 9000: Use & Care Guide
Waterwise 9000: Use & Care Guide
Waterwise 9000: Use & Care Guide
Waterwise 9000™
Countertop Steam Distiller
www.waterwise.com
WARNING: Never remove the boiler while the fan motor is running, or
for 30 minutes after it stops. Severe burns can result from boiling water or
steam. DO NOT change position or location of distiller while it is operating
or cooling.
Figure A
www.waterwise.com
This Distiller produces purified water by using the oldest, most effective
method of water treatment—steam distillation. When the Distiller is
operating, the water temperature rises to 212°F (100°C), killing bacteria,
cysts, and viruses that may be present. As the boiling water (1) converts to
steam (2), it rises and leaves behind dead microbes, dissolved solids, salts,
heavy metals, and other substances. Low boiling light gases that may be
present are discharged through the gaseous vent (3). Steam is then cooled
in the stainless steel condenser (4), turning it into high quality water.
Distilled water percolates through a final polishing coconut shell carbon
filter (5) to enhance quality by adsorption of VOCs (volatile organic
compounds), and is then collected in the Tritan™ collector/dispenser
bottle (6) which is Bisphenol-A (BPA) Free.
Tritan™ is a Trademark of Eastman Chemical Company
This system was tested and certified by the Water Quality Association
against WQA S-400 for the reduction of TDS (Total Dissolved Solids).
It has the product water production rate of 1 gallon per 4.5 hours and has
the product water storage capacity of 1 gallon.
Waterwise 9000
Production rate: 5.5 gallons per day
Model Volts Hertz Watts
North America 9010 120 VAC 60 Hz 750W
North America 9012 120 VAC 60 Hz 750W
Europe 9024 230 VAC 50 Hz 730W
United Kingdom 9025 230 VAC 50 Hz 730W
Southeast Asia 9026 230 VAC 50 Hz 750W
4 Waterwise 9000 Distiller Use & Care Guide
PREPARING FOR FIRST TIME USE
Clean Collector/Dispenser Bottle
• Ensure the dispensing valve (fig. B) is installed and tightened.
• Fill bottle approximately three fourths full with warm tap water.
• Add one or two drops of dish detergent.
• DO NOT install filter cup at this time.
• Seal bottle opening with cap.
• Shake vigorously and drain.
• Rinse thoroughly.
• Add 6 ounces (180 ml) of 3 percent hydrogen peroxide to bottle.
• Fill with warm tap or distilled water (less than 120°F).
• DO NOT install the filter cup at this time.
• Seal bottle opening with cap.
• Shake vigorously and let stand for 20 minutes.
• Drain and rinse thoroughly.
Sterilize and Rinse Carbon Filter Cup
Before installing, fully immerse new filter cup in distilled water for about
five minutes. Then sterilize filter cup by fully immersing in boiling water
for about five minutes. Allow filter to cool before handling. Pour 1 to 2
cups distilled water through filter cup to rinse away any small, harmless
carbon fines (dust). Water draining from the filter cup may contain black
dust. This is typical. The carbon dust is formed as a result of production,
packaging and shipping of filter cup.
Figure B
Install Filter Cup
Bottle Cap Place sterilized filter cup into opening
of collector/dispenser bottle.
Replace Filter Cup
Filter Cup The filter cup should be replaced
every two months or after 60-80
gallons of water processed (which-
ever comes first). Replace more often
should the distilled water begin to
have an unwanted taste or odor.
Dispensing
Valve Discard first gallon of distilled water
as it may contain small, harmless
carbon fines. Order replacement filters
from the outlet where you purchased
your distiller.
Collector/Dispenser Bottle
Gasket
10. Slide boiler into chassis compartment and press firmly to ensure boiler
is properly placed (fig. E). To prevent personal injury or property
damage, the boiler must be fully engaged prior to start-up.
11. Plug power cord into a properly rated, grounded outlet.
12. Press “Start” button at base of boiler (fig. E). “Start” button will illum-
inate when heating; however, the light will go out and boiler will stop
heating if electrical power is interrupted or stopped. If this occurs,
press “Start” button again to restart the distillation cycle.
NOTE: The cooling fan will not start immediately because of a
delayed fan start-up feature. The fan will start once the boiler has
reached a predetermined temperature, approximately 30 to 40 minutes
after starting the cycle.
WARNING: To prevent personal injury, burn and/or scald injury,
DO NOT remove boiler while “Start” button is illuminated or at any time
when the boiler is hot. Always unplug Distiller from wall outlet and allow
boiler to cool completely before removing it from the Distiller (at least 30
minutes). DO NOT change
Figure E position or location of Dis-
Distiller tiller while it is operating or
Chassis cooling.
13. Place prepared carbon
filter cup into opening
at the top of the collec-
tor/dispenser bottle.
DO NOT install cap
onto bottle (fig. F).
Boiler
14. Replace the collector/
dispenser bottle
(fig. F). Make sure the
Start dispensing valve is
Button securely tightened.
Waterwise 9000 Distiller Use & Care Guide 7
Figure F
Filter Cup
Boiler
Dispensing Collector/Dispenser
Valve Bottle
IMPORTANT: The collector/dispenser bottle must be properly placed,
with its cap removed and filter cup in place, for proper water collection.
DO NOT remove collector/dispenser bottle while Distiller is operating.
NOTE: At the end of the distillation cycle (about 4.5 hours), Distiller
will shut off automatically and “Start” light will go out. The fan will
continue to operate for a few minutes.
15. Unplug cord from wall outlet when not in use.
16. DISCARD FIRST GALLON of distilled water as it may contain
some harmless matter from manufacturing and/or packaging.
17 Rinse boiler thoroughly before refilling.
IMPORTANT: Wipe off all water deposits inside the Distiller chassis and
on the outside of the boiler before each distillation cycle.
NOTE: The collector/dispenser bottle will not fill completely. The collec-
tor was designed to hold 1 gallon of water and allow additional space so
that the carbon filter does not remain in contact with the distilled water.
Once distillation cycle is complete, the water bottle may be placed in
refrigerator and used to dispense the distilled water. The filter cup may be
left in or removed and stored in the refrigerator in a sealed plastic bag or
other airtight container. Secure cap onto the bottle to avoid spilling. The
cap must be opened slightly before dispensing water. It is recommended
that the bottle NOT be placed in a freezer as handle may become brittle
and crack.
NOTE: Approximately 5 ounces (150 ml) of water will remain in boiler
at the end of the distillation cycle. This feature reduces scale deposits in
the boiler.
WARNING: To prevent personal injury or electric shock, DO NOT
immerse the Distiller, its boiler, its cord or plugs in water or other liquid.
DISTILLER MAINTENANCE
WARNING: Always be sure to unplug power cord from wall outlet before
cleaning or servicing Distiller.
Cleaning Boiler
Rinse the boiler before every distillation cycle with warm tap water to
remove any loose residue. Loosen securing nut and remove steam baffle
(fig. D). Half fill boiler with warm tap water, agitate and discard the water.
The water should be drained through boiler spout.
Excessive deposits can cause malfunction. As scale deposits build up, use
an approved cleaner, such as KLEENWISE, to remove this deposit. White
vinegar or automatic coffee pot cleaner can also be used. DO NOT operate
Distiller with cleaning solution in boiler. Use a soft plastic or nylon scour-
ing pad if needed. DO NOT use abrasive cleaners, caustic acids, steel wool
pads or metal utensils. Wipe outside of boiler tank with a soft cloth or
sponge and mild soapy water.
IMPORTANT: Wipe off all water deposits inside the Distiller chassis and
on the outside of the boiler before each distillation cycle.
Distiller Chassis
“Start” button lights up, Fan delayed start system Wait about 30 minutes for
but fan does not start. has not activated the fan. the fan to start.
Distiller does not operate. Distiller is not plugged in. Plug Distiller into
appropriate outlet.
Electrical power Press “Start” button to
interruption. restart.
Outlet is defective or Check fuses or circuit
fuse or circuit breaker breakers or call an
has tripped. electrician.
The distilled water has The carbon filter is Replace the carbon filter
an unusual taste. contaminated. cup (page 5).
The collector/dispenser Clean the bottle (page 5).
bottle needs cleaning.
The boiler has been DO NOT overfill boiler.
overfilled. Fill to bottom of four tabs
in boiler opening (fig. D).
No power to boiler. Boiler not fully engaged in Make sure the boiler is
chassis. properly placed (fig. E).
Early shut off and/or Steam baffle improperly Properly install steam
water under boiler. inserted. baffle and steam baffle
securing nut (page 6, #9).
O-ring worn or defective. Replace o-ring.
10 Waterwise 9000 Distiller Use & Care Guide
PRACTICAL USES
FOR CLEAN DISTILLED WATER
Drinking…
it’s healthy and delicious
Complexion Care…
daily cleansing without pore clogging impurities
Cooking…
enhances natural taste and appearance without unsavory chemicals
Aquariums…
fish thrive in a clean, clear, chlorine-free tank
Houseplants…
eliminate brown tips on foliage and salt deposits on flower pots—
enjoy blooms longer
Coffee, Tea & Cocoa…
you’ll enjoy truer, richer flavors while using less
Fruit Juices…
experience the freshly squeezed, natural flavor
Ice Cubes…
crystal clear and sparkling—won’t spoil your drink
Pet Care…
pets will enjoy the same benefits people do
Baby Formulas…
pure enough for formulas, inhalation therapy and herbal tinctures
Registration will not affect warranty coverage, but may expedite processing of your
warranty. Registration is the only way to guarantee you will be notified by Waterwise
of any issues that arise concerning this product.
Waterwise is not responsible or liable for personal injury, property damage, or inciden-
tal or consequential damages arising out of, or in connection with, the use or perfor-
mance of the product or other damages with respect to loss of use, or costs of removal,
installation, or reinstallation.
Waterwise will, at its option, replace or repair the defective part(s) without charge,
provided they are returned, transportation prepaid by owner, to an authorized service
facility or to the address below. Enclose a letter describing the problem, copy of dated
proof of purchase, and your name, address and daytime telephone number.
This limited warranty does not guarantee uninterrupted service. Repair or replace-
ment as provided under this warranty is the exclusive remedy of the purchaser. This
limited warranty is in lieu of all other warranties, expressed or implied, including, but
not limited to, any implied warranty of merchantability or fitness for a particular use
or purpose. This warranty gives you specific legal rights and you may also have other
rights which vary from state to state or province to province. Outside the United States,
a different warranty may apply. For details, please contact your authorized Waterwise
distributor.
If your distiller fails to function properly or requires service, please contact your autho-
rized distributor to arrange for service and/or replacement parts.
3608 Parkway Blvd • Leesburg Florida 34748-9399 • (352) 787-5008 • Fax: (352) 787-8123
www.waterwise.com • E-mail: [email protected]
L20187WT ©2000 Waterwise Inc Printed in USA Form 9801 • Rev 10/12