Error

Description Remark
Code

E1 Indoor room Indoor room temp.


temperature sensor in short
sensor failure circuit, or open
circuit, it can
resume due to the
signal.

E2 Indoor coil Indoor coil temp.


temperature sensor in short
sensor failure circuit, or open
circuit, it can
resume due to the
signal.

E4 EEPROM wrong Being electrified to


test E2 check sum,
or E2 is broken
down.

E7 Communication Communication
failure between failure alarms for 4
indoor and minutes
outdoor contineously, it can
resume due to the
signal.

E14 Indoor fan motor Indoor fan motor


failure wrong wiring or
indoor fan motor
abnormal.

E18 Temperature Outdoor 4-way


cutoff protection valve response
abnormal.
Error
Description Remark
Code

F1 Module failure Outdoor module


abnormal

F2 Outdoor DC motor Outdoor DC motor


failure abnormal

F4 Compressor Compressor
overheat / discharging
discharging temperature over
temperature high protection
protection

F5 Module over
current / current
transducer failure

F6 Outdoor ambient Outdoor ambient


temp. sensor temp. sensor in
abnormal short current or
open circuit

F7 Outdoor Outdoor
suction/defrosting suction/defrosting
temp. sensor temp. sensor in
abnormal short circuit or
open circuit

F8 High pressure High pressure too


abnormal high

F9 Low pressure Low pressure


abnormal abnormal

F10 No AC power
supply
Error
Description Remark
Code

F11 Outdoor PCB Being electrified to


EEPROM abnormal test if the E2 check
sum is correct or
failure

F13 Communication
failure between
outdoor PCB and
module

F14 Compressor Outdoor


discharging temp. compressor
sensor failure discharging temp.
sensor in short
circuit or open
circuit

F15 Compressor Resumable


running faulty

F16 Running state- Outdoor DC


detecting circuit compressor
failure running state-
detecting circuit
failure, or
compressor
abnormal,
resumable

Model: HDU-24CA03/M(R1) HDU-28CA03/M(R1) HDU-36CA03/M(R1) HDU-42CA03/M(R1)


Model: HSU-09/12HVA103/R2(DB)FOR Eorope
Error Code: E1
Fault Description: Room temperature sensor fault
Remark: Indoor room temp. sensor in short circuit, or open circuit, it can resume due to the signal.
Error Code: E2
Fault Description: Heat-exchange sensor fault
Remark: Indoor coil temp. sensor in short circuit, or open circuit, it can resume due to the signal.
Error Code: E4
Fault Description: Indoor EEPROM error
Remark: Being electrified to test E2 check sum, or E2 is broken down.
Error Code: E9
Fault Description: High work-intense protection
Fault unit: Outdoor unit
Error Code: E7
Fault Description: Communication failure between indoor and outdoor
Remark: Communication failure alarms for 4 minutes contineously, it can resume due to the signal.
Error Code: EC
Fault Description: Refrigerant Leakage
Error Code: F12
Fault Description: Outdoor EEPROM fault
Fault unit: Outdoor unit
Error Code: E14
Fault Description: Indoor fan motor malfunction
Remark: Indoor fan motor wrong wiring or indoor fan motor abnormal.
Error Code: F1
Fault Description: The protection error of IPM
Remark: Outdoor module abnormal
Error Code: F2
Fault Description: Overcurrent of the compressor
Remark: Outdoor DC motor abnormal
Error Code: F3
Fault Description: Communication fault between the IPM and outdoor PCB
Fault unit: Outdoor unit
Error Code: F4
Fault Description: Overheat protection error of exhaust temperature sensor
Remark: Compressor discharging temperature over high protection

Error Code: F6
Fault Description: Ambient temperature sensor failure
Remark: Outdoor ambient temp. sensor in short current or open circuit
Error Code: F7
Fault Description: Suction temperature sensor fault
Remark: Outdoor suction/defrosting temp. sensor in short circuit or open circuit
Error Code: F11
Fault Description: deviate from the normal for the compressor
Remark: Being electrified to test if the E2 check sum is correct or failure
Error Code: F19
Fault Description: Power voltage too high or too low
Fault unit: Outdoor unit
Error Code: F21
Fault Description: Defrost temperature sensor fault
Fault unit: Outdoor unit
Error Code: F22
Fault Description: Overcurrent protection of AC electricity for the outdoor model
Fault unit: Outdoor unit
Error Code: F23
Fault Description: Overcurrent protection for single-phase of the compressor
Fault unit: Outdoor unit
Error Code: F25
Fault Description: Discharge temperature sensor fault
Fault unit: Outdoor unit
Error Code: F28
Fault Description: Loop of the station detect error
Fault unit: Outdoor unit
Error Code: F66
Fault Description: Ambient temperature sensor fault

Code: E0
Flash time of compressor running indicate lamp: 10
Trouble contents (old): drainage system trouble
Trouble contents (new): drainage system trouble
Code: E1
Flash time of compressor running indicate lamp: 1
Trouble contents (old): indoor temperature sensor broken
Trouble contents (new): indoor temperature sensor broken
Code: E2
Flash time of compressor running indicate lamp: 2
Trouble contents (old): indoor coil temperature sensor broken
Trouble contents (new): indoor coil temperature sensor broken
Code: E3
Flash time of compressor running indicate lamp: 3
Trouble contents (old): outdoor temperature sensor broken
Trouble contents (new): outdoor temperature sensor broken
Code: E4
Flash time of compressor running indicate lamp: 4
Trouble contents (old): outdoor coil temperature sensor broken
Trouble contents (new): outdoor coil temperature sensor broken

Code: E5
Flash time of compressor running indicate lamp: 5
Trouble contents (old): over current protect limit
Trouble contents (new): over current protect limit
Code: E6
Flash time of compressor running indicate lamp: 6
Trouble contents (old): pressure protect
Trouble contents (new): pressure protect
Code: E7
Flash time of compressor running indicate lamp: 7
Trouble contents (old): communication trouble between wired remote controller and indoor unit.
Trouble contents (new): three phase protect
Code: E8
Flash time of compressor running indicate lamp: 8
Trouble contents (old): Communication trouble between indoor and outdoor unit.
Trouble contents (new): Communication trouble between wired remote controller and indoor unit
Code: E9
Flash time of compressor running indicate lamp: 9
Trouble contents (old): three phase protect
Trouble contents (new): communication trouble between indoor and outdoor unit
Haier Air
Conditioner Remote Control

HSU-09/12HVA103/R2(DB) For Europe Models:


Error Codes and Description indoor and outdoor display

Indoor and Outdoor: E7


Description: Communication fault between indoor and outdoor units
Indoor Malfunction: E1
Description: Room temperature sensor failure
Indoor Malfunction: E2
Description: Heat-exchange sensor failure
Indoor Malfunction: E4
Description: Indoor EEPROM error
Indoor Malfunction: E14
Description: Indoor fan motor malfunction
Indoor Malfunction: E9
Description: High work-E9 intense protection
Error Codes and Description indoor and outdoor display:
Indoor: F12
Outdoor (LED1 flash times): 1
Description: Outdoor EEPROM error
Indoor: F11
Outdoor (LED1 flash times): 2
Description: The protection of IPM
Indoor: F22
Outdoor (LED1 flash times): 3
Description: Over current protection of AC electricity for the outdoor model
Indoor: F11
Outdoor (LED1 flash times) = 4
Description = Communication fault between the IPM and outdoor PCB
Indoor: F11
Outdoor (LED1 flash times) = 6
Description = Power voltage is too high or low
Indoor: F4
Outdoor (LED1 flash times) = 8
Description = Overheat protection for exhaust temperature
Indoor: F21
Outdoor (LED1 flash times) = 10
Description = Frost-removing temperature sensor failure
Indoor: F6
Outdoor (LED1 flash times) = 12
Description = Ambient temperature sensor failure
Indoor: F25
Outdoor (LED1 flash times) = 13
Description = Exhaust temperature sensor failure
Indoor: F11
Outdoor (LED1 flash times) = 19
Description = Loop of the station detect error
Haier Commercial Air Conditioning:

▪ Flash times of LED on mainboard: 1


▪ Trouble description: Eeprom failure
▪ Analyze and diagnose: Outdoor main board eeprom fail
▪ Flash times of LED on mainboard: 2
▪ Trouble description: IPM failure
▪ Analyze and diagnose: IPM failure
▪ Flash times of LED on mainboard: 4
▪ Trouble description: Communication error between main board and spdu module SPDU
Communicition error
▪ Analyze and diagnose: Communication fail over 4 min
▪ Flash times of LED on mainboard: 5
▪ Trouble description: High pressure protection
▪ Analyze and diagnose: System high pressure over 4.15 Mpa
▪ Flash times of LED on mainboard: 6
▪ Trouble description: Module over-voltage protection/ Module lack-voltage protection
▪ Analyze and diagnose: Send from Spdu module
▪ Flash times of LED on mainboard: 8
▪ Trouble description: Compressor discharging temperature protection
▪ Analyze and diagnose: Compressor discharging temperature over 110 centigrade
▪ Flash times of LED on mainboard: 9
▪ Trouble description: Abnomal of DC motor
▪ Analyze and diagnose: jam of DC motor or motor failure
▪ Flash times of LED on mainboard: 10
▪ Trouble description: Abnomal of pipe sensor
▪ Analyze and diagnose: Piping sensor short-circuit or open-circuit
▪ Flash times of LED on mainboard: 12
▪ Trouble description: Abnomal of outdoor ambient sensor
▪ Analyze and diagnose: Outdoor ambient sensor short-circuit or open-circuit
▪ Flash times of LED on mainboard: 13
▪ Trouble description: Abnormal of compressor dischage sensor
▪ Analyze and diagnose: Compressor discharging sensor short-circuit or open-circuit
▪ Flash times of LED on mainboard: 15
▪ Trouble description: Communication error between indoor and outdoor unit
▪ Analyze and diagnose: Communication fail over 4 min
▪ Flash times of LED on mainboard: 16
▪ Trouble description: Lack of refrigerant
▪ Analyze and diagnose: check if there is leakage in the unit
▪ Flash times of LED on mainboard: 17
▪ Trouble description: 4-way valve reverse failure
▪ Analyze and diagnose: Alarm and stop if detect Td-Tci<=15 last for 1min after compressor has
started for 10min in heating mode, confirm the failure if it appears 3 times in one hour.
▪ Flash times of LED on mainboard: 18
▪ Trouble description: Compressor jam (ony for spdu )
▪ Analyze and diagnose: Inner compressor is abnormal jamed
▪ Flash times of LED on mainboard: 19
▪ Trouble description: Module EEV select circuit error
▪ Analyze and diagnose: Module EEV select wrong circuit
▪ Flash times of LED on mainboard: 25
▪ Trouble description: Compressor U-phase over-current
▪ Analyze and diagnose: The current of compressor U-phase is too high
▪ Flash times of LED on mainboard: 25
▪ Trouble description: Compressor V-phase over-current
▪ Analyze and diagnose: The current of compressor V-phase is too high
▪ Flash times of LED on mainboard: 25
▪ Trouble description: Compressor W-phase over-current
▪ Analyze and diagnose: The current of compressor W-phase is too high
▪ Flash times of LED on mainboard: 45
▪ Trouble description: Low pressure protection
▪ Analyze and diagnose: System over pressure under 0.05Mpa

Haier Cassette AC Error Codes


The remote receiver can indicate the failure code

Haier Cassette AC
Error Codes
Safety Instructions and Warnings:

Before starting the air conditioner, read the information given in the User’s Guide carefully.

The User’s Guide contains very important observations relating to the assembly, operation and
maintenance of the air conditioner.

The manufacturer does not accept responsibility for any damages that may arise due to non-
observation of the following instruction.

Haier Window Type AC Error Codes


Abnormity Diagnose

1. Sensor diagnose: 2 seconds after the sensors open circuit or short circuit, the unit will turn off
automatically and the LED will show E0 until the sensors resume.
2. Keystroke circuit error diagnose: When power on for the first time, the PCB will check the
keystroke circuit, if the sampling value is different with the theory value, the LED will show E1,
which means failed keystroke circuit. The keyboard is locked and so invalid, but the remote
control is working normally.
Maintenance Service and Trouble Shooting
If air conditioner does not operate:
▪ Check if unit is plugged in.The plug may have come loose.
▪ Check if the unit is in “off” mode.
▪ The fan control may be in “off” position.
Air from air conditioner is warm:
▪ The A/C setting may need to be raised.
▪ The temperature outside the room is below 65°F。The conpressor will not cycle on if the
temperature outside is below 65°F.
Ice formation on cooling coils:
▪ Outside temperature too cold .Set the unit on fan only setting to defrose ice.
▪ Lower temperature setting.Temperature setting may be too cold.
▪ Unit BTU may be too high for the room

Haier Wall Mounted Type AC Error Codes


Failure code for wall mounted unit(AS182AVERA) —- displayed on the indoor LCD:

E1-E2-E3-
E4-E5-E6-E8-E9
E1-
E2-E3-E4-E5-E6-E9
E1-E2-E3-E4-E7-E14-E18-F1-F2-F4-F5-F6-F7-F8-F9-F10-F11-F13-D-F14-F15-F16
Failure code for fix frequency outdoor unit

Haier Portable AC Error Codes and Troubleshooting:


Haier Portable AC Error Codes

Error
Problem
Codes

E0 Indicates incoming power issues,


such as a low voltage condition or
excessive power consumption.
Unplug the unit for 10 minutes.
Service may be required

E1 Indicates a stuck button on the front


panel key pad. Unplug unit and press
each button firmly to reset the
switches. Then, plug the unit back
into the power supply. Service may
be required
Error
Problem
Codes

E4 Unit has a tank built-in that must be


emptied periodically. E4 indicates
the tank float is stuck. Open the
water tank and verify no debris is
blocking the operation of the float.

STOP Unit has a tank built-in that must be


emptied periodically. STOP indicates
the tank must be emptied or tank
float is stuck. Unit will not run while
STOP appears. Empty the tank. Open
the water reservoir and verify no
debris is blocking the operation of
the float.

High Appears when ambient room


Temp temperature is over 99 degrees F. If
the ambient temperature is not
above 99F, then service may be
required.

Troubleshooting
Problem: Unit does not start or operate
Possible Cause:

1. Power supply cord is not plugged into an outlet.


2. Power supply cord has tripped.
3. The Power button has not been pressed.
4. There is no power to the electrical outlet.
5. A household fuse has blown or a circuit breaker has tripped.
6. The control was programmed for a Time Delay.
7. The batteries in the remote control are dead.
8. The internal water tank is full.
Solution:

1. Plug the power cord into a grounded 3 prong outlet.


2. Press and release the RESET button on the power supply cord.
3. Press the Power button on the Control Panel or Remote Control to turn ON the air conditioner.
4. Plug a working lamp into the outlet to check for power.
5. Replace the fuse or reset the circuit breaker.
6. Cancel the Time Delay.
7. Replace the batteries.
8. Empty the water tank.
Problem: Air conditioner is working but the room is not cooling.
Possible Cause:

1. The room temperature is hot.


2. The control is set incorrectly to Fan or Dehum mode.
3. Airflow is restricted.
4. Temperature set too high.
5. Air filters are dirty or restricted.
6. Air conditioner installed incorrectly.
7. Doors and windows are open.
Solution:

1. Allow time for the room to cool when you first turn on the unit.
2. Set the Mode to Cool and the Fan Speed to High.
3. Remove any obstacles to the airflow and redirect airflow for uniform cooling.
4. Lower the set temperature.
5. Clean the air filter.
6. Check the exhaust hose and window panel for proper installation.
7. Close the doors and windows to the room being cooled to prevent cooled air from escaping.
Problem: Remote control is not working
Possible Cause:

1. Batteries are dead.


2. Batteries are installed incorrectly.
Solution:

1. Replace the batteries.


2. Make sure the batteries are inserted in the correct position.

Haier MRV Air Conditioner Error Codes

Haier Air Conditioner Manual PDF


Haier Air Conditioner Manual PDF 2
Haier Cassette AC MANUAL PDF
Haier WindowType Air Conditioner Manual PDF
Haier Portable AC Manual PDF

*PLEASE SEND ME ANY COMMENT, SUGGESTION OR CORRECTION YOU MAY HAVE.

Related Posts

Haier MRV Air Conditioner Error Codes

34 Comments

1.

Aleksandar Strugar

Hello, how to solve a bug on the model of the AS 122MGERA indoor wall unit. It appears on the unit
itself error E08. It’s a small VRV system
February 22, 2020Reply
2.

Alwyn

Hi, how to fix a F8 code error?


December 30, 2019Reply

3.

Arne

How to fix F3 code?


October 3, 2019Reply

4.

aurel

Hi.
I have F22 eror code at Europe model.
Looks to be Overcurrent protection of AC electricity for the outdoor model
It’s enought to replace the cable?
June 18, 2019Reply

5.

Arif

Hi, what is FE error code in Haier Air conditioner? itsnt F3 its FE. Thank you!
May 19, 2019Reply

6.
peterhenry

I bought Ac last year is now show me Ec and it have stop cooling. what will I do
March 8, 2019Reply

admin

Error Code: EC
Fault Description: Refrigerant Leakage
March 8, 2019Reply

7.

Umair Ali Khan

What is simple F error and how to fix it?


August 29, 2018Reply

8.

Muhammad Safeer

last year i bought AC, now display panel showing Error-E7. kindly how to fix that problem.
August 15, 2018Reply

9.

Asif Mahmood

At least how much voltage required for 1 ton DC inverter ?


July 9, 2018Reply
10.

Asif Mahmood

I am using 2 ton inverter unit from two months today I saw an error F28 displayed at indoor unit and
unit is not working what do I do I am working as a technician at Haier cws please reply me regards
June 25, 2018Reply

11.

Anthony Ramsey

My portable flashes stop and none of the buttons does anything


June 14, 2018Reply

12.

Janak

F 25 error and ac switched off


June 3, 2018Reply

13.

m umar

plz send me hair dc inverter falt eror codes all


March 18, 2018Reply

14.

Peceli lomani
Thank you
February 20, 2018Reply

15.

Ssemagobwe Godfrey

Dear expertise of Haier Air conditioner, am an Hvac technician doing service and some few repairs
on Acs,but there are some errors which disturbs me, like error E7 and E1,what really bring such
errors and how do you go about it?. Thanks and happy new year.
January 1, 2018Reply

16.

Munirajulu srinivasulu

Error E7 what is the problem


December 12, 2017Reply

17.

Najam Abbas

I have a problem in Haier cabinet AC model no hpu 48cj03 after 5 minutes of out door start the
power light of LCD blinks two time
May 6, 2017Reply

18.

Chris

Hi sir, my ducted AD96NAHAEA displays E9 and led are off on both boards. Please help
January 10, 2017Reply

sajjad ali

dear,
if old model then there is problrm of three phase prtect
and if new model the there is aproblem in communication between ondoor and outdoor unit.
June 15, 2017Reply

19.

Athol Sclanders

New model 12000btu split unit showing E7. Error is communication error between indoor and
outdoor units. What can I do to correct this?
October 11, 2016Reply

20.

Louis Acevedo

My Haier unit displays a “t7” error code not listed here. I reset the breaker switch, left unit off
overnight, replugged it in while in off position waited a few hours and turned it back on to no avail.
Any suggestions?
October 7, 2016Reply

21.

Amber

What does code E3 mean. I got home from work and my breaker was blown. Turned it back on and
my Ac won’t work . It flashes error code E3
September 2, 2016Reply

sajjad ali

dear,
outdoor temprature sensor broken
June 15, 2017Reply

22.

Larry

How do you fix an E1 code on window unit


August 15, 2016Reply

23.

Kim

E4 what diesitmean
August 9, 2016Reply

24.

Ashim

What is error code E2&E5. How fix this?


July 19, 2016Reply

25.

Aslam
Ya and well
April 22, 2016Reply

26.

Vipin

Sir what is the solution for E2 error and this error is there in my window ac
April 16, 2016Reply

Afifa

How to Fix E2 error?


October 2, 2017Reply

Add a Comment
Cancel reply
Comment:

Name:

Email Address:

Website:

Save my name, email, and website in this browser for the next time I comment.

27.

Gharsha

F1 err code
April 11, 2016Reply
28.

gayan

Why outdoor led blink continuesly


April 11, 2016Reply

29.

mark currier

my indoor unit is not working the fins open up then close back up and its blinking f 12 any ideas
April 9, 2016Reply

30.

david colaivalu

Very useful….thank you


March 17, 2016Reply

Search

AC Brands
▪ Acson
▪ Actron
▪ Akai
▪ Amana
▪ Aux
▪ Beko
▪ Bryant
▪ Carrier
▪ Chigo
▪ Chunlan
▪ Comfortaire
▪ Daikin
▪ Delonghi
▪ Derby
▪ Dometic
▪ Electriq
▪ Electrolux
▪ Fisher
▪ Friedrich
▪ Frigidaire
▪ Fujitsu
▪ Fujitsu General
▪ Galanz
▪ Garrison
▪ GE
▪ Goodman
▪ Gree
▪ Haier
▪ Hisense
▪ Hitachi
▪ Home
▪ Hyundai
▪ IFB
▪ Klimaire
▪ Koppel
▪ Lennox
▪ LG
▪ Lloyd
▪ Maxon
▪ McQuay
▪ Midea
▪ Mitsubishi Electric
▪ Mitsubishi Heavy
▪ Onida
▪ Panasonic
▪ Pridiom
▪ Rheem
▪ Rittal
▪ Samsung
▪ Sanyo
▪ Sharp
▪ Shinco
▪ SoleusAir
▪ TCL
▪ Teco
▪ Thermal Zone
▪ Toshiba
▪ Toyotomi
▪ Trane
▪ Unionaire
▪ Vivax
▪ Westinghouse
▪ York

Recent Comments
▪ bernardo martinez on Frigidaire Air Conditioner Error Codes
▪ jorden on Teco AC Error Codes and Troubleshooting
▪ Leon on Gree Air Conditioners Error Codes
▪ Ansari javed on IFB AC Error Codes and Troubleshooting
▪ Ramesh on Videocon Air Conditioner Error Codes
▪ Rick on Goodman Air Conditioner Error Codes
▪ Rajesh kumar on IFB AC Error Codes and Troubleshooting
▪ Sandep Kandhwal on IFB AC Error Codes and Troubleshooting
▪ Satis Mhatre on Onida Air Conditioner Error Codes
▪ Bittu on Videocon Air Conditioner Error Codes

AC Error Code Copyright © 2020.

© 2014-2020 ACErrorCode.com. All rights reserved. | View our Privacy policy | Terms of
use | Contact Back to Top ↑

This website uses cookies to ensure you get the best experience Our Privacy Policy Allow Cookies

NecessaryAlways Enabled

You might also like