Trustability Board Mount Pressure Sensors: Datasheet
Trustability Board Mount Pressure Sensors: Datasheet
Pressure Sensors
SSC Series—Standard Accuracy, Compensated/Amplified
±1.6 mbar to ±10 bar | ±160 Pa to ±1 MPa | ±0.5 inH2O to ±150 psi
Digital or Analog Output
Datasheet
TruStability® Board Mount Pressure Sensors
The TruStability® Standard Accuracy Silicon Ceramic (SSC) Series is a piezoresistive silicon pressure sensor offering a
ratiometric analog or digital output for reading pressure over the specified full scale pressure span and temperature range.
The SSC Series is fully calibrated and temperature compensated for sensor offset, sensitivity, temperature effects, and non-
linearity using an on-board Application Specific Integrated Circuit (ASIC). Calibrated output values for pressure are updated at
approximately 1 kHz for analog and 2 kHz for digital.
The SSC Series is calibrated over the temperature range of -20 °C to 85 °C [-4 °F to 185 °F]. The sensor is characterized for
operation from a single power supply of either 3.3 Vdc or 5.0 Vdc.
These sensors measure absolute, gage, or differential pressures. The absolute versions have an internal vacuum reference
and an output value proportional to absolute pressure. Gage versions are referenced to atmospheric pressure and provide an
output proportional to pressure variations from atmosphere. Differential versions allow measurement of pressure between two
pressure ports.
The TruStability® pressure sensors are intended for use with non-corrosive, non-ionic gases, such as air and other dry gases.
Available options extend the performance of these sensors to non-corrosive, non-ionic liquids for pressure ranges above
40 mbar | 4 kPa | 20 inH2O.
All products are designed and manufactured according to ISO 9001 standards.
±160 Pa to ±1 MPa. . . . . . . . . . . . . . . . . . . . . 15
Dimensional Drawings
Portfolio Overview . . . . . . . . . . . . . . . . . . . . . . 31
Additional Information. . . . . . . . . . . . . . . . . . . 32
Offset
+
Full Scale Span
+
Pressure Non-Linearity
+
Pressure Hysteresis = Accuracy
+ = Total
Error Band
Pressure Non-Repeatability
+
Thermal Effect on Offset
+
Thermal Effect on Span
+
Thermal Hysteresis
sensing.honeywell.com 3
Features Industry-leading accuracy
Extremely tight accuracy of ±0.25 %FSS BFSL (Full Scale Span Best Fit Straight
and Benefits Line) reduces software needs to correct system inaccuracies, minimizing system
design time:
• Avoids additional customer calibration.
• Helps to improve system efficiency.
• Often simplifies software development.
Industry-leading flexibility
Modular, flexible design with many package styles (with the same industry-
leading stability), pressure ports, and options simplify integration into the device
manufacturer’s application.
Energy efficient
Extremely low power consumption (less than 10 mW, typ.):
• Reduces system power requirements.
• Enables extended battery life.
• Optional sleep mode available upon special request.
4 sensing.honeywell.com
Features Output: ratiometric analog; I2C- or SPI-compatible
14-bit digital output (min. 12-bit sensor resolution)
and Benefits Accelerates performance through reduced conversion requirements and the
convenience of direct interface to microprocessors.
Small size
Miniature 10 mm x 10 mm [0.39 in x 0.39 in] package is very small when
compared to many board mount pressure sensors:
• Occupies less area on the PCB.
• Typically allows for easy placement on crowded PCBs or in small devices.
sensing.honeywell.com 5
Potential Applications
MEDICAL
• Airflow monitors
• Anesthesia machines
• Blood analysis machines
• Gas flow instrumentation
• Kidney dialysis machines
• Oxygen concentrators
• Pneumatic controls
• Respiratory machines
• Sleep apnea equipment
• Ventilators
• Spirometers
• Nebulizers
• Hospital room air pressure
INDUSTRIAL
• Barometry
• Flow calibrators
• Gas chromatography
• Gas flow instrumentation
• HVAC
• Life sciences
• Pneumatic control
• VAV (Variable Air Volume) control
• Clogged HVAC filter detection
• HVAC transmitters
• Indoor air quality
6 sensing.honeywell.com
General Specifications
Absolute maximum ratings are the extreme limits the device will withstand without damage.
1
Characteristic Parameter
Humidity:
gases only (See “Options N and D” in Figure 4.) 0% to 95% RH, non-condensing
liquid media only (See “Options T and V” in Figure 4.) 100% condensing or direct liquid media on Port 1
sensing.honeywell.com 7
General Specifications
\
CAUTION
PRODUCT DAMAGE FOR SENSORS WITH LIQUID MEDIA OPTION (ONLY AVAILABLE 60 MBAR |
6 KPA | 1 PSI AND ABOVE)
• Ensure liquid media is applied to Port 1 only; Port 2 is not compatible with liquids.
• Ensure liquid media contains no particulates. All TruStability® sensors are dead-ended devices. Particulates can accumulate
inside the sensor, causing damage or affecting sensor output.
• Recommend that the sensor be positioned with Port 1 facing downwards; any particulates in the system are less likely to enter
and settle within the pressure sensor if it is in this position.
• Ensure liquid media does not create a residue when dried; build-up inside the sensor may affect sensor output. Rinsing of a
dead-ended sensor is difficult and has limited effectiveness for removing residue.
• Ensure liquid media are compatible with wetted materials. Non-compatible liquid media will degrade sensor performance and
may lead to sensor failure.
Failure to comply with these instructions may result in product damage.
Absolute Output is proportional to the difference between applied pressure and a built-in vacuum reference.
Differential Output is proportional to the difference between the pressures applied to each port (Port 1 – Port 2).
Gage Output is proportional to the difference between applied pressure and atmospheric (ambient) pressure.
8 sensing.honeywell.com
Analog Operating Specifications
Supply current:
3.3 Vdc — 2.1 2.8 mA
5.0 Vdc — 2.7 3.5
Response time — 1 — ms
Clipping limit:
upper — — 97.5 %Vsupply
lower 2.5 — —
sensing.honeywell.com 9
Digital Operating Specifications
Supply current:
3.3 Vdc — 3.1 3.9 mA
5.0 Vdc — 3.7 4.6
low — — 20 %Vsupply
high 80 — —
Accuracy 6
— — ±0.25 %FSS BFSL8
Ratiometricity of the sensor (the ability of the device output to scale to the supply voltage) is achieved within the specified operating voltage.
2
The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.
3
Operating temperature range: The temperature range over which the sensor will produce an output proportional to pressure.
4
Compensated temperature range: The temperature range over which the sensor will produce an output proportional to pressure within the specified
5
performance limits.
Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25 °C [77 °F]. Includes
6
8
Full Scale Span (FSS): The algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of the pressure range.
(See Figure 4 for ranges.)
9
Insignificant for pressure ranges above 40 mbar | 4 kPa | 20 inH2O.
0 0 0x0000
10 1638 0x0666
50 8192 0x2000
90 14746 0x399A
10 sensing.honeywell.com
Transfer Function Limits
80
70
60 Ideal
50
2% Total Error Band
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10
Pmin. Pmax.
Pressure (example unit)
0.8 x Vsupply
Output (V) = x (Pressureapplied – Pmin.) + 0.10 x Vsupply
Pmax. – Pmin.
Digital Versions
90
80
70
60 Ideal
50
2% Total Error Band
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10
Pmin. Pmax.
Pressure (example unit)
80%
Output (% of 214 counts) = x (Pressureapplied – Pmin.) + 10%
Pmax. – Pmin.
1
Transfer Function “A” is shown. See Figure 4 for other available transfer function options.
sensing.honeywell.com 11
Total Error Band Values
Figure 3. Total Error Band Values for Full Scale Span Pressure Ranges
Differential Gage
150 psi 10 bar | 1 MPa 150 psi 10 bar | 1 MPa
1 psi 1 psi
20 inH2O 20 inH2O
Ultra-Low Ultra-Low
Pressure 40 mbar | 4 kPa Pressure 40 mbar | 4 kPa
12 sensing.honeywell.com
Nomenclature and Order Guide
NN 2 I C, Address 0x28
2
6 I2C, Address 0x68
No ports NN No ports NN No ports
3 I C, Address 0x38
2
7 I2C, Address 0x78
Pressure Range3, 4
Dual axial
AA barbed ports, ±1.6 mbar to ±10 bar ±160 Pa to ±1 MPa ±0.5 inH2O to ±150 psi
opposite sides Absolute Absolute Absolute
001BA 0 bar to 1 bar 100KA 0 kPa to 100 kPa 015PA 0 psi to 15 psi
Single axial Single axial
AN barbed port AN Single axial
barbed port AN barbed port
1.6BA 0 bar to 1.6 bar 160KA 0 kPa to 160 kPa 030PA 0 psi to 30 psi
2.5BA 0 bar to 2.5 bar 250KA 0 kPa to 250 kPa 060PA 0 psi to 60 psi
Single axial
004BA 0 bar to 4 bar 400KA 0 kPa to 400 kPa 100PA 0 psi to 100 psi
Single axial Single axial
LN barbless port LN barbless port LN barbless port 006BA 0 bar to 6 bar 600KA 0 kPa to 600 kPa 150PA 0 psi to 150 psi
010BA 0 bar to 10 bar 001GA 0 kPa to 1 MPa
Fastener
mount, dual
FF axial barbed
ports, opposite
Differential Differential Differential
sides 1.6MD ±1.6 mbar 160LD ±160 Pa 0.5ND ±0.5 inH2O
Fastener 2.5MD ±2.5 mbar 250LD ±250 Pa 001ND ±1 inH2O
mount, single
FN axial barbed 004MD ±4 mbar 400LD ±400 Pa 002ND ±2 inH2O
port
006MD ±6 mbar 600LD ±600 Pa 004ND ±4 inH2O
Ribbed
fastener mount, 010MD ±10 mbar 001KD ±1 kPa 005ND ±5 inH2O
GN single axial
barbed port008B 016MD ±16 mbar 1.6KD ±1.6 kPa 010ND ±10 inH2O
025MD ±25 mbar 2.5KD ±2.5 kPa 020ND ±20 inH2O
Fastener
NB mount, dual 040MD ±40 mbar 004KD ±4 kPa 030ND ±30 inH2O
axial ports,
same side 060MD ±60 mbar 006KD ±6 kPa 001PD ±1 psi
100MD ±100 mbar 010KD ±10 kPa 005PD ±5 psi
Single radial Single radial
RN Single radial
barbed port
RN barbed port RN barbed port 160MD ±160 mbar 016KD ±16 kPa 015PD ±15 psi
250MD ±250 mbar 025KD ±25 kPa 030PD ±30 psi
Dual radial Dual radial Dual radial 400MD ±400 mbar 040KD ±40 kPa 060PD ±60 psi
RR barbed ports,
same side
RR barbed ports,
same side
RR barbed ports,
same side 600MD ±600 mbar 060KD ±60 kPa
001BD ±1 bar 100KD ±100 kPa
Dual radial Dual radial Dual radial 1.6BD ±1.6 bar 160KD ±160 kPa
DR barbed ports,
opposite sides
DR barbed ports,
opposite sides
DR barbed ports,
opposite sides 2.5BD ±2.5 bar 250KD ±250 kPa
004BD ±4 bar 400KD ±400 kPa
Single radial Single radial
JN barbless port JN barbless port JN Single radial
barbless port Gage Gage Gage
2.5MG 0 mbar to 2.5 mbar 250LG 0 Pa to 250 Pa 001NG 0 inH2O to 1 inH2O
Dual radial Dual radial Dual radial 004MG 0 mbar to 4 mbar 400LG 0 Pa to 400 Pa 002NG 0 inH2O to 2 inH2O
JJ barbless ports,
same side
JJ barbless ports,
same side
JJ barbless ports,
same side 006MG 0 mbar to 6 mbar 600LG 0 Pa to 600 Pa 004NG 0 inH2O to 4 inH2O
010MG 0 mbar to 10 mbar 001KG 0 kPa to 1 kPa 005NG 0 inH2O to 5 inH2O
Fastener
mount, dual 016MG 0 mbar to 16 mbar 1.6KG 0 kPa to 1.6 kPa 010NG 0 inH2O to 10 inH2O
HH radial barbed
ports, same
side 025MG 0 mbar to 25 mbar 2.5KG 0 kPa to 2.5 kPa 020NG 0 inH2O to 20 inH2O
Fastener 040MG 0 mbar to 40 mbar 004KG 0 kPa to 4 kPa 030NG 0 inH2O to 30 inH2O
mount, single
HN radial barbed 060MG 0 mbar to 60 mbar 006KG 0 kPa to 6 kPa 001PG 0 psi to 1 psi
port 100MG 0 mbar to 100 mbar 010KG 0 kPa to 10 kPa 005PG 0 psi to 5 psi
Manifold 160MG 0 mbar to 160 mbar 016KG 0 kPa to 16 kPa 015PG 0 psi to 15 psi
MN mount, outer
diameter seal 250MG 0 mbar to 250 mbar 025KG 0 kPa to 25 kPa 030PG 0 psi to 30 psi
400MG 0 bar to 400 mbar 040KG 0 kPa to 40 kPa 060PG 0 psi to 60 psi
Manifold 600MG 0 bar to 600 mbar 060KG 0 kPa to 60 kPa 100PG 0 psi to 100 psi
SN mount, inner
diameter seal 001BG 0 bar to 1 bar 100KG 0 kPa to 100 kPa 150PG 0 psi to 150 psi
1.6BG 0 bar to 1.6 bar 160KG 0 kPa to 160 kPa
Options5, 6 2.5BG 0 bar to 2.5 bar 250KG 0 kPa to 250 kPa
004BG 0 bar to 4 bar 400KG 0 kPa to 400 kPa
N Dry gases only, no diagnostics
006BG 0 bar to 6 bar 600KG 0 kPa to 600 kPa
D Dry gases only, diagnostics on
010BG 0 bar to 10 bar 001GG 0 kPa to 1 MPa
T Liquid media on Port 1, no diagnostics
V Liquid media on Port 1, diagnostics on
sensing.honeywell.com 13
Pressure Range Specifications
±1.6 mbar to ±10 bar
Table 8. Pressure Range Specifications for ±1.6 mbar to ±10 bar
Pressure4 (%FSS)
Figure 4) (%FSS) (%FSS)
Absolute
001BA 0 1 bar - 2 4 - 2% - ±0.25%
1.6BA 0 1.6 bar - 4 8 - 2% - ±0.25%
2.5BA 0 2.5 bar - 6 8 - 2% - ±0.25%
004BA 0 4 bar - 8 16 - 2% - ±0.25%
006BA 0 6 bar - 17 17 - 2% - ±0.25%
010BA 0 10 bar - 17 17 - 2% - ±0.25%
Differential
1.6MD -1.6 1.6 mbar 335 675 1000 3450 ±3.5% ±2.5% ±0.5%
2.5MD -2.5 2.5 mbar 335 675 1000 3450 ±3% ±1.5% ±0.35%
004MD -4 4 mbar 335 675 1000 3450 ±2.5% ±1% ±0.35%
006MD -6 6 mbar 335 675 1000 3450 ±2% ±1% ±0.35%
010MD -10 10 mbar 375 750 1250 5450 ±2% ±0.75% ±0.25%
016MD -16 16 mbar 375 750 1250 5450 ±2% ±0.75% ±0.25%
025MD -25 25 mbar 435 850 1350 10450 ±2% ±0.75% ±0.25%
040MD -40 40 mbar 435 850 1350 10450 ±2% ±0.75% ±0.25%
060MD -60 60 mbar - 850 1000 10000 ±2% - ±0.25%
100MD -100 100 mbar - 1400 2500 10000 ±2% - ±0.25%
160MD -160 160 mbar - 1400 2500 10000 ±2% - ±0.25%
250MD -250 250 mbar - 1400 2500 10000 ±2% - ±0.25%
400MD -400 400 mbar - 2000 4000 10000 ±2% - ±0.25%
600MD -600 600 mbar - 2000 4000 10000 ±2% - ±0.25%
001BD -1 1 bar - 4 8 10 ±2% - ±0.25%
1.6BD -1.6 1.6 bar - 8 16 10 ±2% - ±0.25%
2.5BD -2.5 2.5 bar - 8 16 10 ±2% - ±0.25%
004BD -4.0 4.0 bar - 16 17 10 ±2% - ±0.25%
Gage
2.5MG 0 2.5 mbar 335 675 1000 3450 ±4% ±3% ±0.5%
004MG 0 4 mbar 335 675 1000 3450 ±3% ±1.5% ±0.5%
006MG 0 6 mbar 335 675 1000 3450 ±3% ±1.5% ±0.35%
010MG 0 10 mbar 335 675 1000 3450 ±2% ±1% ±0.35%
016MG 0 16 mbar 335 675 1000 3450 ±2% ±1% ±0.25%
025MG 0 25 mbar 375 750 1250 5450 ±2% ±0.75% ±0.25%
040MG 0 40 mbar 375 750 1250 5450 ±2% ±0.75% ±0.25%
060MG 0 60 mbar - 850 1000 5450 ±2% ±0.75% ±0.25%
100MG 0 100 mbar - 850 1000 10000 ±2% - ±0.25%
160MG 0 160 mbar - 850 1000 10000 ±2% - ±0.25%
250MG 0 250 mbar - 1400 2500 10000 ±2% - ±0.25%
400MG 0 400 mbar - 2000 4000 10000 ±2% - ±0.25%
600MG 0 600 mbar - 2000 4000 10000 ±2% - ±0.25%
001BG 0 1 bar - 2 4 10 ±2% - ±0.25%
1.6BG 0 1.6 bar - 4 8 10 ±2% - ±0.25%
2.5BG 0 2.5 bar - 8 16 10 ±2% - ±0.25%
004BG 0 4 bar - 8 16 16 ±2% - ±0.25%
006BG 0 6 bar - 17 17 17 ±2% - ±0.25%
010BG 0 10 bar - 17 17 17 ±2% - ±0.25%
Working pressure: The maximum pressure that may be applied to any port of the sensor in continuous use. This pressure may be outside the operating pressure range
1
limits (Pmin. to Pmax.) in which case the sensor may not provide a valid output until presssure is returned to within the operating pressure range. Tested to 1 million cycles,
minimum.
Overpressure: The maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure
2
to higher pressures may cause permanent damage to the product. Unless otherwise specified this applies to all available pressure ports at any temperature with the operating
temperature range.
3
Burst pressure: The maximum pressure that may be applied to any port of the product without causing escape of pressure media. Product should not be expected to function after
exposure to any pressure beyond the burst pressure.
Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without causing changes in specified
4
performance.
5
Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all errors due to offset, full scale
span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal effect on span, and thermal hysteresis (see Figure 1).
Total Error Band after Auto-Zero: The maximum deviation from the ideal transfer function over the entire compensated pressure range at a constant temperature and supply voltage
6
for a minimum of 24 hours after an auto-zero operation. Includes all errors due to full scale span, pressure non-linearity, pressure hysteresis, and thermal effect on span.
14 sensing.honeywell.com
Pressure Range Specifications
±160 Pa to ±1 MPa
Table 9. Pressure Range Specifications for ±160 Pa to ±1 MPa
Pressure4 (%FSS)
Figure 4) (%FSS) (%FSS)
Absolute
100KA 0 100 kPa - 200 400 - ±2% - ±0.25%
160KA 0 160 kPa - 400 800 - ±2% - ±0.25%
250KA 0 250 kPa - 600 800 - ±2% - ±0.25%
400KA 0 400 kPa - 800 1600 - ±2% - ±0.25%
600KA 0 600 kPa - 1700 1700 - ±2% - ±0.25%
001GA 0 1 MPa - 1700 1700 - ±2% - ±0.25%
Differential
160LD -160 160 Pa 33500 67500 100000 345000 ±3.5% ±2.5% ±0.5%
250LD -250 250 Pa 33500 67500 100000 345000 ±3% ±1.5% ±0.35%
400LD -400 400 Pa 33500 67500 100000 345000 ±2.5% ±1% ±0.35%
600LD -600 600 Pa 33500 67500 100000 345000 ±2% ±1% ±0.35%
001KD -1 1 kPa 37.5 75 125 545 ±2% ±0.75% ±0.25%
1.6KD -1.6 1.6 kPa 37.5 75 125 545 ±2% ±0.75% ±0.25%
2.5KD -2.5 2.5 kPa 43.5 85 135 1045 ±2% ±0.75% ±0.25%
004KD -4 4 kPa 43.5 85 135 1045 ±2% ±0.75% ±0.25%
006KD -6 6 kPa - 85 100 1000 ±2% - ±0.25%
010KD -10 10 kPa - 140 250 1000 ±2% - ±0.25%
016KD -16 16 kPa - 140 250 1000 ±2% - ±0.25%
025KD -25 25 kPa - 140 250 1000 ±2% - ±0.25%
040KD -40 40 kPa - 200 400 1000 ±2% - ±0.25%
060KD -60 60 kPa - 200 400 1000 ±2% - ±0.25%
100KD -100 100 kPa - 400 800 1000 ±2% - ±0.25%
160KD -160 160 kPa - 800 1600 1000 ±2% - ±0.25%
250KD -250 250 kPa - 800 1600 1000 ±2% - ±0.25%
400KD -400 400 kPa - 1600 1700 1000 ±2% - ±0.25%
Gage
250LG 0 250 Pa 33500 67500 100000 345000 ±4% ±3% ±0.5%
400LG 0 400 Pa 33500 67500 100000 345000 ±3% ±1.5% ±0.5%
600LG 0 600 Pa 33500 67500 100000 345000 ±3% ±1.5% ±0.35%
001KG 0 1 kPa 33.5 67.5 100 345 ±2% ±1% ±0.35%
1.6KG 0 1.6 kPa 33.5 67.5 100 345 ±2% ±1% ±0.25%
2.5KG 0 2.5 kPa 37.5 75 125 545 ±2% ±0.75% ±0.25%
004KG 0 4 kPa 37.5 75 125 545 ±2% ±0.75% ±0.25%
006KG 0 6 kPa - 85 100 545 ±2% ±0.75% ±0.25%
010KG 0 10 kPa - 85 100 1000 ±2% - ±0.25%
016KG 0 16 kPa - 85 100 1000 ±2% - ±0.25%
025KG 0 25 kPa - 140 250 1000 ±2% - ±0.25%
040KG 0 40 kPa - 200 400 1000 ±2% - ±0.25%
060KG 0 60 kPa - 200 400 1000 ±2% - ±0.25%
100KG 0 100 kPa - 200 400 1000 ±2% - ±0.25%
160KG 0 160 kPa - 400 800 1000 ±2% - ±0.25%
250KG 0 250 kPa - 800 1600 1000 ±2% - ±0.25%
400KG 0 400 kPa - 800 1600 1600 ±2% - ±0.25%
600KG 0 600 kPa - 1700 1700 1700 ±2% - ±0.25%
001GG 0 1 MPa - 1.7 1.7 1.7 ±2% - ±0.25%
Working pressure: The maximum pressure that may be applied to any port of the sensor in continuous use. This pressure may be outside the operating pressure range
1
limits (Pmin. to Pmax.) in which case the sensor may not provide a valid output until presssure is returned to within the operating pressure range. Tested to 1 million cycles,
minimum.
Overpressure: The maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure
2
to higher pressures may cause permanent damage to the product. Unless otherwise specified this applies to all available pressure ports at any temperature with the operating
temperature range.
3
Burst pressure: The maximum pressure that may be applied to any port of the product without causing escape of pressure media. Product should not be expected to function after
exposure to any pressure beyond the burst pressure.
Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without causing changes in specified
4
performance.
5
Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all errors due to offset, full scale
span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal effect on span, and thermal hysteresis (see Figure 1).
Total Error Band after Auto-Zero: The maximum deviation from the ideal transfer function over the entire compensated pressure range at a constant temperature and supply voltage
6
for a minimum of 24 hours after an auto-zero operation. Includes all errors due to full scale span, pressure non-linearity, pressure hysteresis, and thermal effect on span.
sensing.honeywell.com 15
Specifications
±0.5 inH2O to ±150 psi
Table 10. Pressure Range Specifications for 0.5 inH2O to 150 psi
(%FSS)
Figure 4) (%FSS) (%FSS)
Absolute
015PA 0 15 psi - 30 60 - ±2% - ±0.25%
030PA 0 30 psi - 60 120 - ±2% - ±0.25%
060PA 0 60 psi - 120 240 - ±2% - ±0.25%
100PA 0 100 psi - 250 250 - ±2% - ±0.25%
150PA 0 150 psi - 250 250 - ±2% - ±0.25%
Differential
0.5ND -0.5 0.5 inH2O 135 270 415 1400 ±4% ±3% ±0.5%
001ND -1 1 inH2O 135 270 415 1400 ±3% ±1.5% ±0.35%
002ND -2 2 inH2O 135 270 415 1400 ±2% ±1% ±0.35%
004ND -4 4 inH2O 150 300 500 2200 ±2% ±0.75% ±0.25%
005ND -5 5 inH2O 150 300 500 2200 ±2% ±0.75% ±0.25%
010ND -10 10 inH2O 175 350 550 4200 ±2% ±0.75% ±0.25%
020ND -20 20 inH2O 175 350 550 4200 ±2% ±0.75% ±0.25%
030ND -30 30 inH2O 175 350 550 4200 ±2% ±0.75% ±0.25%
001PD -1 1 psi - 10 15 150 ±2% - ±0.25%
005PD -5 5 psi - 30 40 150 ±2% - ±0.25%
015PD -15 15 psi - 60 120 150 ±2% - ±0.25%
030PD -30 30 psi - 120 240 150 ±2% - ±0.25%
060PD -60 60 psi - 250 250 250 ±2% - ±0.25%
Gage
001NG 0 1 inH2O 135 270 415 1400 ±4% ±3% ±0.5%
002NG 0 2 inH2O 135 270 415 1400 ±3% ±1.5% ±0.35%
004NG 0 4 inH2O 135 270 415 1400 ±2% ±1% ±0.35%
005NG 0 5 inH2O 135 270 415 1400 ±2% ±1% ±0.25%
010NG 0 10 inH2O 150 300 500 2200 ±2% ±0.75% ±0.25%
020NG 0 20 inH2O 175 350 550 4200 ±2% ±0.75% ±0.25%
030NG 0 30 inH2O 175 350 550 4200 ±2% ±0.75% ±0.25%
001PG 0 1 psi - 10 15 150 ±2% - ±0.25%
005PG 0 5 psi - 30 40 150 ±2% - ±0.25%
015PG 0 15 psi - 30 60 150 ±2% - ±0.25%
030PG 0 30 psi - 60 120 150 ±2% - ±0.25%
060PG 0 60 psi - 120 240 250 ±2% - ±0.25%
100PG 0 100 psi - 250 250 250 ±2% - ±0.25%
150PG 0 150 psi - 250 250 250 ±2% - ±0.25%
Working pressure: The maximum pressure that may be applied to any port of the sensor in continuous use. This pressure may be outside the operating pressure range limits (Pmin. to
1
Pmax.) in which case the sensor may not provide a valid output until pressure is returned to within the operating pressure range. Tested to 1 million cycles, minimum.
Overpressure: The maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure
2
to higher pressures may cause permanent damage to the product. Unless otherwise specified this applies to all available pressure ports at any temperature with the operating
temperature range.
3
Burst pressure: The maximum pressure that may be applied to any port of the product without causing escape of pressure media. Product should not be expected to function after
exposure to any pressure beyond the burst pressure.
Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without causing changes in specified
4
performance.
5
Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all errors due to offset, full scale
span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal effect on span, and thermal hysteresis
Total Error Band after Auto-Zero: The maximum deviation from the ideal transfer function over the entire compensated pressure range at a constant temperature and supply voltage
6
for a minimum of 24 hours after an auto-zero operation. Includes all errors due to full scale span, pressure non-linearity, pressure hysteresis, and thermal effect on span.
16 sensing.honeywell.com
Available Standard Configurations
Figure 5. All Available Standard Configurations (Dimensional drawings on pages noted below.)
Pressure Port
Package
Code
DIP SMT SIP
NN
AA — —
page 24
AN
LN
FF — —
page 25
FN — —
page 26
GN — —
page 26
NB — —
page 26
RN
sensing.honeywell.com 17
Available Standard Configurations
Figure 5. All Available Standard Configurations (Continued; dimensional drawings on pages noted below.)
Pressure Port
Package
Code
DIP SMT SIP
RR
DR
JN — —
JJ
HH — —
page 28
HN — —
page 29
MN — —
page 29
SN — —
page 29
18 sensing.honeywell.com
Dimensional Drawings
DIP Packages
Figure 6. DIP Package Dimensional Drawings (For reference only: mm [in].)
Dimensions
DIP NN: No ports
0,25
5,44 [0.010] 10,0
[0.214] [0.39]
8 7 6 5
6,99 13,3
PORT 1 PORT 2 [0.53]
[0.275]
PIN 1
INDICATOR
1 2 3 4
9,24
2,54 TYP. [0.364]
[0.100] 10,85
[0.427]
8X 0,46
[0.018]
PIN 1 PORT 1
INDICATOR
1 2 3 4 9,24
2,54 TYP. [0.364]
[0.100] 11,21
[0.441]
8X 0,46
[0.018]
6,99 13,3
PORT 2 [0.275 ] [0.53]
PORT 1
PIN 1
INDICATOR 2,47
[0.097]
1 2 3 4
2, 54 TYP. 9,24
[0.100] [0.364]
11,21
[0.441]
6,95
[0.274]
1,00
[0.039]
8X 0,46
[0.018]
sensing.honeywell.com 19
Dimensional Drawings
DIP Packages
Figure 6. DIP Package Dimensional Drawings (continued)
Dimensions
DIP RN: Single radial barbed
port
0,25
5,80 [0.010] 10,0
[0.228] [0.39]
8 7 6 5
4,2
13,3 [0.17]
[0.53]
PORT 1 PORT 2 6,99
[0.275]
1,93
[0.076]
1 2 3 4
9,24
2,54 TYP. [0.364]
[0.100] 11,21
[0.441]
8X 0,46
[0.018]
4,65
[0.183]
1 2 3 4
9,24
2,54 TYP. [0.364]
[0.100]
11,21
[0.441]
3,78
[0.149]
8X 0,46
[0.018]
PORT 2 PORT 1
9,24
1 2 3 4 [0.364]
2,54 TYP.
[0.100] 11,21
[0.441]
3,78
[0.149]
8X 0,46
[0.018]
20 sensing.honeywell.com
Dimensional Drawings
DIP and SMT Packages
Figure 6. DIP Package Dimensional Drawings (continued)
Dimensions
DIP JN: Single radial barbless
port
9,91
7,58 [0.390]
6,75 [0.298] 1,9
3,28 3,28 9,40
[0.266] [0.370] [0.07]
8 7 6 5 [0.129] [0.129]
2,34 4,1
[0.092] PORT 1 [0.16]
13,3
[0.53] 7,00
PORT 1 PORT 2 [0.276]
1 2 3 4 9,24 0,25
[0.364] [0.010]
11,92
[0.469]
6,70
[0.264]
8 X 0,461
[0.018]
1,94
[0.076]
8 X 0,46
[0.018]
5,44 10,0
[0.214] [0.39]
8 7 6 5
6,99 13,3
[0.53]
PORT 1 PORT 2 [0.275]
PIN 1
INDICATOR
1 2 3 4
4,80 8X 0,46
2,54 TYP. [0.189] [0.018]
[0.100] 6,41
[0.252]
sensing.honeywell.com 21
Dimensional Drawings
SMT Packages
Figure 7. SMT Package Dimensional Drawings (continued)
Dimensions
SMT AN: Single axial barbed port
13,75
[0.541] 10,0
[0.39]
8 7 6 5 7,95
[0.313]
13,3
4,93 DIA. 6,99 [0.53]
[0.194] PORT 2 [0.275]
PIN 1 PORT 1
INDICATOR
1 2 3 4 4,80 8X 0,46
2,54 TYP. [0.189] [0.018]
[0.100] 6,77
[0.266]
13,75
[0.541] 10,0
5,80
[0.228] [0.394]
8 7 6 5
13,3
6,99 [0.53]
PORT 2 [0.275]
PORT 1
PIN 1
2,47 DIA.
INDICATOR [0.097]
1 2 3 4 4,80 8X 0,46
2,54 TYP. [0.189] [0.018]
[0.100] 6,77
[0.266]
5,80 10,0
[0.228] [0.39]
8 7 6 5
4,2
13,3 [0.17]
[0.53]
6,99
PORT 1 PORT 1 PORT 2 [0.275]
1,93 DIA.
[0.076]
1 2 3 4
4,80 8X 0,46
2,54 TYP. [0.189] [0.018]
[0.100]
6,77
[0.266]
22 sensing.honeywell.com
Dimensional Drawings
SMT Packages
Figure 7. SMT Package Dimensional Drawings (continued)
Dimensions
SMT RR: Dual radial barbed
ports, same side
6,16 10,0
4,0 [0.242] [0.39]
8 7 6 5
[0.16] 2X 1,93 DIA.
PORT 1 13,3 [0.076]
[0.53]
6,99
PORT 2 PORT 1 PORT 2 [0.275]
4,6
[0.18]
1 2 3 4
4,80 8X 0,46
2,54 TYP. [0.189] [0.018]
[0.100]
6,77
[0.266]
3,78
[0.149]
15,8
[0.62]
2X 2,93 6,16 10,0
[0.115] [0.242] [0.39]
8 7 6 5
1 2 3 4 4,80 8X 0,46
2,54 TYP. [0.189] [0.018]
[0.100] 6,77
3,78
[0.149] [0.266]
6,51 9,91
[0.256] [0.390]
6,75 3,28 2,21 9,40 1,87
[0.266] 8 [0.074]
7 6 5 [0.129] [0.087] [0.370]
2,34 4,15
[0.092] PORT 1 13,3 [0.163]
PORT 1 [0.53] 6,98
7,00
PORT 2 [0.276] [0.275]
1 2 3 4 4,80 8 X 1,28
2,54 8 X 0,461
[0.189] [0.018] [0.050]
[0.100] 7,48
[0.294]
5,38
[0.212]
sensing.honeywell.com 23
Dimensional Drawings
SMT and SIP Packages
Figure 7. SMT Package Dimensional Drawings (continued)
Dimensions
SMT JJ: Dual radial
barbless ports, same side
9,91
7,58 [0.390]
2X 6,75 [0.298] 9,40 4,76
[0.266] 3,28 [0.370] [0.187]
8 7 6 5 [0.129]
2X 2,34 4,15
[0.092] PORT 1 [0.163]
PORT 1 PORT 2
7,00 6,98
13,3 [0.276] [0.275]
[0.53]
4,162
[0.1639] 1 2 3 4 5,68 8 X 0,461 8 X 1,28
2,54 [0.189] [0.050]
[0.100] 8,36 [0.018]
[0.329]
5,38
[0.212]
10,0 4,87
[0.39] [0.192]
15,2
[0.60]
1 2 3 4
0,25
4X 0,51 [0.010] 2,54 TYP.
[0.020] [0.100]
10,0 22,06
[0.39] [0.869]
2X 4.93 DIA.
[0.194]
15,2
[0.60]
0,25
4X 0,51 [0.010] 2,54 TYP.
[0.020] [0.100]
24 sensing.honeywell.com
Dimensional Drawings
SIP Packages
Figure 8. SIP Package Dimensional Drawings (continued)
Dimensions
SIP AN: Single axial barbed
port
10,0 13,75
[0.39] [0.541]
4.93 DIA.
[0.194]
15,2
[0.60]
0,25
4X 0,51 [0.010] 2,54 TYP.
[0.020] [0.100]
10,0 13,75
[0.39] [0.541]
10,0 PORT 2
[0.39]
PORT 1
2,47 DIA.
[0.097]
15,2
[0.60]
1 2 3 4
0,25
4X 0,51 [0.010] 2,54 TYP.
[0.020] [0.100]
17,78
[0.700]
PORT 2 PORT 1
2X 3.94 DIA.
[0.155] 2X 4,78 DIA.
[0.188]
20,16
[0.794]
0,25
4X 0,51 [0.010] 2,54 TYP.
[0.020] [0.100]
sensing.honeywell.com 25
Dimensional Drawings
SIP Packages
Figure 8. SIP Package Dimensional Drawings (continued)
Dimensions
SIP FN: Fastener mount,
single axial barbed port
29,48
[1.161]
16,38
23,12 [0.645]
[0.910]
17,78
[0.700]
3257 3257
20,16
[0.794]
0,25 2,54 TYP.
4X 0,51 [0.010] [0.100]
[0.020]
19,06
[0.750]
PORT 2 PORT 1
2X 3,94 DIA.
[0.155] 4.78 DIA .
[0.188]
10,63
[0.418]
0,25
4X 0,51 [0.010] 2,54 TYP.
[0.020] [0.100]
2X 4,80 DIA.
[0.189]
PORT 2 22,87
[0.900]
2X 3.50 DIA.
[0.138] PORT 1
13
[0.52]
0,25
4X 0,51 [0.010]
[0.020] 2,54 TYP.
[0.100]
26 sensing.honeywell.com
Dimensional Drawings
SIP Packages
Figure 8. SIP Package Dimensional Drawings (continued)
Dimensions
SIP RN: Single radial barbed
port
10,0
[0.39] 5,80
[0.228]
PORT 1 PORT 1
10,0
[0.39] PORT 2 1,92 DIA.
[0.076]
15,2
[0.60]
1 2 3 4
0,25
4X 0,51 [0.010] 2,54 TYP.
[0.020] [0.100]
10,0 6,16
[0.39] [0.243]
PORT 1 PORT 1
10,0
PORT 2 [0.39] PORT 2 2X 1,92 DIA.
[0.076]
15,2
[0.60]
1 2 3 4
0,25
4X 0,51 [0.010] 2,54 TYP.
[0.020] [0.100]
15,8
[0.62]
10,0 6,16
[0.39] [0.243]
10,0
[0.39]
PORT 2 PORT 1
2X 4.93 DIA.
[0.194]
15,2
[0.60]
1 2 3 4
0,25
4X 0,51 [0.010] 2,54 TYP.
[0.020] [0.100]
sensing.honeywell.com 27
Dimensional Drawings
SIP Packages
Figure 8. SIP Package Dimensional Drawings (continued)
Dimensions
SIP JN: Single radial barbless
port
7,58 10,0
6,75 [0.298] [0.39] 1,7
[0.266] 3,28 2,2 9,40 [0.07] 1,9
2,34 [0.129] [0.087] [0.370] [0.07]
[0.092] PORT 1
7,00
[0.276] PORT 2 10,0
[0.39]
25,0
[0.98]
15,20
[0.598]
1 2 3 4
1,14 2,1
[0.045] 4 X 0,51 2,54 TYP.
[0.08] [0.100]
[0.020]
7,58
6,75 [0.298] 1,7 4,76
[0.266] 3,28 [0.07] [0.187]
2X 2,34 10,0 1,9
[0.129] [0.39]
[0.092] PORT 1 [0.07]
5,8
7,00 [0.23]
[0.276] 10,0
[0.39]
4,2 PORT 2
[0.16]
25,0
[0.98]
15,20
[0.598]
1 2 3 4
1,14 2,1
[0.045] 4X 0,51 2,54 TYP.
[0.08] [0.100]
[0.020]
28,96
[1.140]
11,27
[0.444]
0,25
4X 0,51 [0.010] 2,54 TYP.
[0.020] [0.100]
28 sensing.honeywell.com
Dimensional Drawings
SIP Packages
Figure 8. SIP Package Dimensional Drawings (continued)
Dimensions
SIP HN: Fastener mount single
radial barbed port 23,12
[0.910] 7,97
4,78 DIA. [0.314]
[0.188]
3257
28,96
[1.140]
PORT 2
2X 3,94 DIA.
[0.155]
11,27
[0.444]
0,25
4X 0,51 [0.010] 2,54 TYP.
[0.020] [0.100]
5,36
PORT 2 [0.211] PORT 1
15,24 .DIA
[0.600]
12,5
[0.49]
0,25
4X 0,51 [0.010] 2,54 TYP.
[0.020] [0.100]
PORT 2
5,1
12,57 [0.20]
[0.495] PORT 1
13,11
[0.516]
15,6
[0.61]
1 2 3 4
sensing.honeywell.com 29
Pinouts, PCB Pad Layout
Output Type Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8
IC
2
GND Vsupply SDA SCL NC NC NC NC
IC
2
GND Vsupply SDA SCL
1,143
[0.045]
0,813
[0.032] 0,914
13,08 2,032 [0.036]
[0.515] [0.080] 9,40
[0.370] 2,54
[0.100]
2,54 2,54
[0.100] [0.100]
30 sensing.honeywell.com
TruStability® Board Mount Pressure Sensors Portfolio Overview
Series
Characteristic
HSC SSC TSC NSC
Package:
DIP (Dual In-Line Pin)
SMT (Surface Mount Technology)
SIP (Single In-Line Pin)
Option:
dry gases only, no diagnostics (all pressure ranges)
dry gases only, diagnostics on (all pressure ranges) — —
liquid media on port 1, no diagnostics (±60 mbar to ±10 bar | ±6 kPa to ±1 MPa | ±1 psi to ±150 psi)
liquid media on port 1, diagnostics on (±60 mbar to ±10 bar | ±6 kPa to ±1 MPa | ±1 psi to ±150 psi) — —
Pressure range:
Absolute:
1 bar to 10 bar | 100 kPa to 1 MPa | 15 psi to 150 psi —
Differential:
±60 mbar to ±10 bar | ±6 kPa to ±1 MPa | ±1 psi to ±150 psi
±1.6 mbar to ±40 mbar | ±160 Pa to ±4 kPa | ±0.5 inH2O to ±30 inH2O —
Gage:
60 mbar to 10 bar | 6 kPa to 1 MPa | 1 psi to 150 psi
2.5 mbar to 40 mbar | 250 Pa to 4 kPa | 1 inH2O to 30 inH2O —
Temperature compensated —
Amplified — —
Output type:
analog
digital (SPI and I2C) — —
Transfer function:
10% to 90% of Vsupply (analog), 214 counts (digital) — —
5% to 95% of Vsupply (analog), 214 counts (digital) — —
5% to 85% of Vsupply (analog), 214 counts (digital) — —
4% to 94% of Vsupply (analog), 214 counts (digital) — —
Supply voltage:
3.3 Vdc — —
5.0 Vdc — —
1.5 Vdc to 12.0 Vdc (for pressure ranges >60 mbar | 6 kPa | 1 psi) — —
2.7 Vdc to 6.5 Vdc (for pressure ranges <40 mbar | 4 kPa | 20 inH2O) — — —
Accuracy <0.25 %FSS BFSL
Compensated temperature range:
-20 °C to 85 °C [-4 °F to 185 °F] — — —
0 °C to 85 °C [32 °F to 185 °F] — — —
0 °C to 50 °C [32 °F to 122 °F] — — —
sensing.honeywell.com 31
ADDITIONAL INFORMATION
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s standard
product warranty applies unless agreed to otherwise by Honeywell
in writing; please refer to your order acknowledgement or consult
your local sales office for specific warranty details. If warranted
goods are returned to Honeywell during the period of coverage,
Honeywell will repair or replace, at its option, without charge
those items it finds defective. The foregoing is buyer’s sole
remedy and is in lieu of all other warranties, expressed or
implied, including those of merchantability and fitness for
a particular purpose. In no event shall Honeywell be liable
for consequential, special, or indirect damages.
32 sensing.honeywell.com
Sales and Service
Honeywell serves its customers through
a worldwide network of sales offices,
representatives and distributors. For
application assistance, current
specifications, pricing or name of the
nearest Authorized Distributor, contact
your local sales office or email us at
[email protected]. Visit us on
the Web at sensing.honeywell.com
Authorized Distributor
Honeywell:
SSCSANN001BGAA5 SSCSANN001PGAA5 SSCSRRN015PGAA5 SSCSRRN400MDAA5 SSCSRRN100MG2A3
SSCSMNN001PGAA5 SSCSMNN001PG2A3 SSCSMNN005PGAA3 SSCSMNN030PGAA3 SSCSMNN030PGAA5
SSCSMNN060PGAA3 SSCSMNN100PGAA5 SSCSMNN150PGAA5 SSCSMNN015PAAA5 SSCSMNN100PA2A3
SSCSMNN250MG2A3 SSCSMNN600MGAA5 SSCSMNN001BGAA5 SSCSMNN001BG2A3 SSCSMNN010BGAA5
SSCSMNN004NDAA5 SSCSSNN005PDAA5 SSCSSNN015PDAA5 SSCSSNN005PGAA5 SSCSSNN030PGAA5
SSCSSNN150PGAA5 SSCSSNN015PAAA5 SSCSFNN001PGAA5 SSCSHHN001PDAA5 SSCDANV005PGAA5
SSCDANV015PGAA3 SSCDANV030PG2A3 SSCDANV150PGAA5 SSCDLNN010BGAA5 SSCDLNN100PGAA5
SSCDLNN150PGAA5 SSCMLNN005PG2A5 SSCMLNN015PG2A5 SSCMLNN015PGSA3 SSCMLNN030PASA3
SSCMLNN150PGAA5 SSCDDRT030PDAA3 SSCDRRN002NDAA5 SSCMNNT015PASA3 SSCSFNN150PGAA5
SSCSHNT060PAAA5 SSCSMNT100MD2A3 SSCSNBN001NDAC5 SSCSNBN002NDAA5 SSCSNBN005NDAA5
SSCSNBN005NGAA5 SSCMRRN002NDSA3 SSCDRRN005NDAA5 SSCMLNN010MGAA5 SSCSHHN100MD2A5
SSCSHHN100MDAA5 SSCMRRN004NGAA3 SSCMRND030PG2A3 SSCDLNT1.6BAAA5 SSCDRRN002ND2A5
SSCDRRT250MDAA5 SSCSMND002NGAA5 SSCSMND005NGAA5 SSCSMND010NGAA5 SSCSNBN030NDAA5
SSCSSND002NGAA5 SSCSSND005NGAA5 SSCSSND010NGAA5 SSCMRNV015PG3A3 SSCSHHN100MGAA5
SSCSANN015PAAA5 SSCSMNN010KGAF5 SSCSMNN050KGAF5 SSCSMNN100KGAF5 SSCSMNN600MGAF5
SSCSSNN001PGAA5 SSCSSNN015PGAA5 SSCSSNN100PGAA5 SSCDRRN005PGAA3 SSCMRRN100MGAF5
SSCSMNN001BGAF5 SSCDRRN001PDAA5 SSCDRRN005PDAA5 SSCDRRN015PDAA5 SSCDRRN030PDAA5
SSCDRRN001PGAA5 SSCDRRN005PGAA5 SSCDRRN060MDAA5 SSCDRRN100MDAA5 SSCDRRN160MDAA5
SSCDRRN250MDAA5 SSCDRRN100MGAA5 SSCDRRN010NDAA5 SSCDRRN020NDAA5 SSCDRRN001PD2A5