Series: Direct Solenoid and Solenoid Pilot Operated Valves
Series: Direct Solenoid and Solenoid Pilot Operated Valves
Series: Direct Solenoid and Solenoid Pilot Operated Valves
Series 55
Individual mounting Series
inline
35
Manual operator
100
Sealed solenoid
enclosure
200
55
56
Pilot filter 57
58
Pilot exh.
Ext. pilot port Ext. pilot 59
Pilot housing U cup Internal pilot
supply
Pilot cartridge
Pilot piston
Check valve 45
3
EXH.
3
EXH.
2 2
1
IN
700
Accumulator CYL. CYL.
1
Precision ground molded, IN 900
balanced spool
Normally closed main
spool shown
82
Air/spring return
6300
45 Consult “Precautions” page 356 before use, installation or service of MAC Valves.
100% WARRANTY
OF
PRODUCTION
TESTED
100%
18 MONTHS
Series 55
VALVE CONFIGURATIONS AVAILABLE • Ability to use a pilot signal pressure different from the main valve pressure. Pilot signal
• 3-Way Normally Open or Normally Closed (solenoid or remote air). can be from 30 to 150 PSI, regardless of main valve pressure.
• 2-Way (by plugging a port) Normally Open or Normally Closed (solenoid or remote air). • A manual operator and position indicator standard.
• Internal pilot or External pilot for vacuum to 30 PSI main valve pressures on solenoid or
SPECIAL APPLICATIONS:
25 on remote air operated models. Manual and mechanical operators available.
• VACUUM APPLICATIONS: Connect the vacuum source to port #3 with port #1 open to
SERIES FEATURES-REMOTE AIR PILOT OPERATED VALVES atmosphere, and use external pilot on solenoid pilot operated models. On remote air
These air versions feature: pilot models, use -RE.
• A large checked accumulator for air/spring return. • SELECTOR APPLICATIONS: Pipe higher pressure to port #1 and lower pressure to port #3.
• Balanced spool unaffected by back pressure in the exhaust or by inlet restrictions. • INTERNAL PILOT: Use for main valve pressure of 30 to 150 PSI on all models. Includes
May be plugged for 2-way operation. ball check in the body and an M5x0.8 plug installed in the external pilot port.
• Use on lube or non-lube service. • EXTERNAL PILOT: An external pilot supply is required when main valve pressures are
lower than 30 psi on solenoid pilot or 25 psi on remote air pilot operated models. To
SERIES FEATURES-REMOTE AIR PILOT, PILOT OPERATED
VALVES convert from internal to external pilot on solenoid models simply rotate pilot housing
These special air versions have the same features as the remote air pilot operated 180 degrees and connect external pilot source. (Use either M5 or#10-32 fitting.) On
models, but additionally feature: remote air pilot models, specify -RE.
46 Consult “Precautions” page 356 before use, installation or service of MAC Valves.
Direct solenoid and solenoid pilot operated valves
Series 55
Function Port size Flow (Max) Individual mounting Series
3/2 NO-NC, 2/2 NO-NC 1/4” - 3/8” 2.2 Cv inline
OPERATIONAL BENEFITS
47 Consult “Precautions” page 356 before use, installation or service of MAC Valves.
100%
18
WARRANTY
OF
PRODUCTION
TESTED
100% MONTHS
Series 55
technical data
Spare parts : • Solenoid operator (power ≥ 4 W) : D1-XXAA, cover mounting screws 35206 and seal 16234.
• Pilot valve : PID-XXYZZ, including mounting screws 35214 and seal 16363. • Check valve : 70061.
56,0
2 MTG. HOLES
Ø 6,6 mm INLET & CYL PORTS
EXT
PILOT
112,5
EXHAUST PORT.
3/8”
2 1
43,7
38,0
26,0
23,5
44,5
29,5
56,0
46,0
48 Consult “Precautions” page 364 before use, installation or service of MAC Valves
O p t i o n s
OPTIONS
Codification table for voltages / Manual operator / Electrical connection / Wire length
- Pilot operated valves with pilots type 100 Series - pilot operated valves with pilots type 200 Series
Series : 55 - 56 - 700 - 800 - 900 Series : 200 - 57 - 58 - 59.
- 6300 - 6500 - 6600 - 1300
- ISO 1 - ISO 2 - ISO 3.
- MAC 125 - MAC 250 - MAC 500
349 Consult “Precautions” page 356 before use, installation or service of MAC Valves.
OPTIONS
Used on valve series: 100, 55, 56, 700, 800, 900, 6300, 6500, 6600, 1300, MVA1C, Used on valve series: 200, 57, 58, 59.
MVA2B, MVA3B, MAC125, MAC250, MAC500.
1. VOLTAGE (100 Serie type coil) 1. VOLTAGE (200 Serie type coil)
- XX Y ZZ VOLTAGE - XX Y ZZ VOLTAGE
11 120/60, 110/50 11 120/60, 110/50, 24 VDC (6 W)
12 240/60, 220/50 12 240/60, 220/50
13 100/60, 100/50 13 100/60, 100/50
15 200/60, 200 /50 14 200/60, 200/50
16 10/60 20 6/60
20 6/60 21 12/60
21 12/50, 12/60 22 24/60, 24/50
22 24/60, 24/50 23 32/60, 32/50
23 32/60, 32/50 24 48/60, 42/50
24 48/60, 42/50 25 240/50
26* 380/50, 440/50, 440/60, 480/60 26 480/60, 440/50
29 220/60 27 127/60
34 127/50, 120/50 28 415/50
35 48/50 29 220/60
36 16/60 30 380/50
B1 24/50 31 550/60, 550/50
50 24 VDC (6 W) 32 120/60, 110/50
51 24 VDC (4 W) 33 600/60
54 12 VDC (4 W) 34 127/50
55 12 VDC (6 W) 35 48/50
57 12 VDC (2.5 W) 50 24 VDC (6 W)
59 24 VDC (2.5 W) 51 24 VDC (4.5 W)
60 12 VDC (8.5 W) 52 24 VDC (2.5 W)
61 24 VDC (8.5 W) 53 24 VDC (1.0 W)
64 6 VDC (6 W) 55 12 VDC (6 W)
65 32 VDC (7 W) 57 12 VDC (2.5 W)
66 48 VDC (5.8 W) 58 48 VDC (2.5 W)
67 64 VDC (7.5 W) 60 12 VDC (9.5 W)
68 120 VDC (6.4 W) 61 24 VDC (8.5 W)
69* 220 VDC (8.7 W), 250 VDC (11.2 W) 64 6 VDC (8.5 W)
75 90 VDC (8.8 W) 65 32 VDC (10 W)
76* 100 VDC (6.9 W) 66 48 VDC (11.5 W)
84* 125 VDC (10.9 W) 67 64 VDC (10.5 W)
87* 24 VDC (17.1 W) 68 120 VDC (12.3 W)
88* 12 VDC (17.4 W) 69 250 VDC (9.2 W)
89* 36 VDC (18.8 W) 71 8 VDC (8.2 W)
90 28 VDC (8.2 W) 72 24 VDC (12 W)
91* 6 VDC (10.6 W) 73 198 VDC (10 W)
92 190 VDC (6.5 W) 74 72 VDC (11.3 W)
94 3 VDC (7 W) 75 90 VDC (11.3 W)
95 38 VDC (6.4 W) 76 100 VDC (9 W)
A1 24 VDC (1 W) 77 220 VDC (10 W), 230 VDC (11.6 W)
A2 12 VDC (1 W) 78* 24 VDC (24 W)
A3 9 VDC (1 W) 80 55 VDC (10.6 W)
MOD. DD01 : Protection diode (DC) - MAX. 8.5W 82 170 VDC (11.1 W)
MOD. MOV1 : Protection varistor (AC) - MAX. 8.5W 83 15 VDC (8.1 W)
* Voltages are CLSF only 84 125 VDC (10 W)
86 36 VDC (11 W)
93* 12 VDC (24 W)
350 Consult “Precautions” page 356 before use, installation or service of MAC Valves.
O p t i o n s
OPTIONS
2. MANUAL OPERATOR (Common options for 100 & 200 Series type coils)
- XX Y ZZ MANUAL OPERATOR
0 No operator 5* No Operator with Light
1 Non-locking recessed 6* Non-Locking Recessed with Light
2 Locking recessed 7* Locking Recessed with Light
3 Non-locking extended 8* Non-Locking Extended with Light
4 Locking extended 9* Locking Extended with Light
* Lights used with “AA” electrical connection
3. ELECTRICAL CONNECTION (100 Serie type coil) 3. ELECTRICAL CONNECTION (200 Serie type coil)
351 Consult “Precautions” page 356 before use, installation or service of MAC Valves.
OPTIONS
4. COIL WIRE LENGTH (Common options for 100 & 200 Serie type coils)
352 Consult “Precautions” page 356 before use, installation or service of MAC Valves.