Applications: TYPE: Rutile

1. SF-70W is a flux-cored wire for welding weathering grade steels using CO2 shielding gas. It has a high deposition rate and good slag detachability. 2. It is designed for welding 70Kpsi class weather resistant steels and for construction applications using atmospheric corrosion resisting steels. 3. Proper preheating between 50-150°C and interpass temperatures must be used to prevent hydrogen cracking, and one-side welding defects can occur with incorrect parameters such as high welding speed.

Uploaded by

sattar12345
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
54 views1 page

Applications: TYPE: Rutile

1. SF-70W is a flux-cored wire for welding weathering grade steels using CO2 shielding gas. It has a high deposition rate and good slag detachability. 2. It is designed for welding 70Kpsi class weather resistant steels and for construction applications using atmospheric corrosion resisting steels. 3. Proper preheating between 50-150°C and interpass temperatures must be used to prevent hydrogen cracking, and one-side welding defects can occur with incorrect parameters such as high welding speed.

Uploaded by

sattar12345
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

현대핸드북(영문)_5-수정 2013.7.

24 12:51 PM 페이지223 백제2번 2540DPI 200LPI

SF-70W JIS Z3320 YFA-50W


TYPE : Rutile

Applications
SF-70W is an all position flux cored wire for use with CO₂shielding gas. This wire is designed for
the welding of weathering grade steels where weld metal and base metal color match is primary
consideration.

Characteristics on Usage
SF-70W has a high deposition rate and excellent slag detachability. Its main applications are with
70Kpsi class weather poof steel and construction work using atmospheric corrosion resisting
steels.

Notes on Usage
① Proper preheating(50~150° C)(122~302℉) and interpass temperature must be used in order to
release hydrogen which may cause cracking in weld metal when electrodes are used for
medium and heavy plates.
② One-side welding defects such as hot cracking may occur with wrong welding parameter such
as high welding speed.
③ Use 100% CO₂gas.

Welding Position Current Shielding Gas


DC + CO₂

1G 2F 3G 4G
(PA) (PB) (PF) (PE)

FCAW
Typical Chemical Composition of All-Weld Metal (%)
C Si Mn P S Cr Ni Cu
0.04 0.45 1.05 0.017 0.011 0.50 0.35 0.40

Typical Mechanical Properties of All-Weld Metal


YS TS EL Temp. CVN-Impact Value
MPa(lbs/in2) MPa(lbs/in2) (%) ℃ (℉) J (ft・lbs)
510 (74,000) 580 (84,200) 28 0 (32) 60 (44)

Approval I Packing
Dia. (mm) 1.2 1.4 1.6 Spool(kg) 12.5 15 20
(in) .045 .052 1/16 (lbs) 28 33 44

Sizes Available and Recommended Currents (Amp.)


Size mm (in) 1.2 (.045) 1.4 (.052) 1.6 (1/16)
F & HF 200~300 250~350 300~400
V-up,OH 120~260 140~270 180~280
V-down 200~300 250~350 300~400