Model Number Structure: Digital Display

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Digital Display

M7F
A Series of Three- to Five-digit Digital
Display Units with a Character Height of
14 mm. Models available with either red or
green displays.
• Red or green displays with a character height of 14 mm are
available for a variety of applications and locations.
• Miniature design with a 50-mm depth.
• Incorporating a connector, thus saving wiring effort.
• Connecting to OMRON's PLCs via dedicated PLC cables (sold
separately).
• Units and minus symbols are displayed (three- and four-digit
model only).
• Incorporating a zero suppression function.
• The power supply can freely change between 12 and 24 VDC.
• CE Marking. UL certification approval.

Model Number Structure


■ Model Number Legend
M7F-@@@@@
1 2 3 4 5
1. No. of Numeral Display Digits 4. Display Color
(No. of 7-segment LED Indicators) Code Color
Code No. of digits 䎰䎚䎩䏂䎧䎶䏂䎨䏂䎖䏂䎔䎑䏉䏐
R Red
3 3 digits G Green
4 4 digits
5 5 digits 5. Display Contents
Code Display Contents
2. Input Method
F Numerals and minus symbol
Code Input Method T Numerals and units
P Static positive logic None Numerals only
N Static negative logic
Note: 1. The input type for the five-digit model is dynamic only.
D Dynamic 2. Dynamic input is available with the four-digit model as well as the five-
digit model.
3. LED 3. The minus symbol and units are available with three and four-digit
models only.
Code Character Height 4. Three-digit models with numerals only are not available.
1 14 mm

Construction and Nomenclature


■ Nomenclature s

I/O Connector (OMRON's XG4A-2031)

Use with OMRON's XG4M-2030-T, XG5M-2032-N, XG5M-2035-N or


equivalent socket.
Connected to OMRON's PLCs with ease by using OMRON's
G79-@C, G79-Y@C, or G79-O@C-@ Cable. Refer to page 3 for details.

Seven-segment LED Power Supply Terminal DIP Switch

Character height: 14 mm Connect 12 to 24 VDC. Used for decimal point and negative value settings.
Color: Red or green Refer to page 6 for details.
Character: Numerals only
Numerals and minus symbol (for three- and four-digit models only)
Numerals and units (for three- and four-digit models only)

http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.


1
M7F
Ordering Information
■ List of Models ■ Accessories
No. of
digits
Appearance Display
color
Input
method
Logic Display contents Model (Order Separately)
3 Red Static Positive Numerals and minus symbol M7F-3P1RF
Numerals and units M7F-3P1RT* Unit Plate
Negative Numerals and minus symbol M7F-3N1RF • Choose the required unit plate from the
Numerals and units M7F-3N1RT* following tables in order to attach it to the
Green Static Positive Numerals and minus symbol M7F-3P1GF Unit Display Unit.
Numerals and units M7F-3P1GT* • Unit plates are replaceable.
Negative Numerals and minus symbol M7F-3N1GF • Ten unit plates are sold as a set.
Numerals and units M7F-3N1GT*
4 Red Static Positive Numerals only M7F-4P1R Display Single item (sheet only):
contents 1 Set of 10 sheets
Numerals and minus symbol M7F-4P1RF
M7F-1
Numerals and units M7F-4P1RT* Blank
display

Negative Numerals only M7F-4N1R


Numerals and minus symbol M7F-4N1RF M7F-RPM-1
rpm
Numerals and units M7F-4N1RT*
Dynamic Positive Numerals only M7F-4D1R M7F-PER-1
Numerals and minus symbol M7F-4D1RF
%
Numerals and units M7F-4D1RT* M7F-KG-1
Green Static Positive Numerals only M7F-4P1G kg
Numerals and minus symbol M7F-4P1GF M7F-MM-1
Numerals and units M7F-4P1GT* mm
Negative Numerals only M7F-4N1G
M7F-M-1
Numerals and minus symbol M7F-4N1GF m
Numerals and units M7F-4N1GT*
M7F-DOC-1
Dynamic Positive Numerals only M7F-4D1G
°C
Numerals and minus symbol M7F-4D1GF
Numerals and units M7F-4D1GT* M7F-PCS-1
pcs
5 Red Dynamic Positive Numerals only M7F-5D1R
Green Dynamic Positive Numerals only M7F-5D1G

Connectable PLCs Compatibility with OMRON PLCs (Examples)


M7F model PLC's output method PLC Output Unit M7F model
Static output Dynamic CS1W-OD211 M7F-@N@@
Input Logic input PNP output NPN output output C200H-OD215/218/219
C500-OD213
Static Positive ❍ × × CQM1-OD213
Negative × ❍ × CS1W-OD212 M7F-@P@@
Dynamic × × ❍ C500-OD212
C200H-OD215 M7F-@D@@
❍: Connectable (See note 1.)
×: Not connectable
Note: 1. External resistance not required
2. Refer to External Connections on page 9 for details.

http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.


2
M7F
Cables
Use the following cables and connectors to connect the M7F to the PLC or other devices.

Model name Application Appearance Ordering Information


G79-@C Connects the M7F
Cable with and a single device.
Connectors Applicable PLC
(1 to 1) Output Units:
C500-OD415CN,
C200H-OD215, and
C200H-MD215
(Output Units
incorporating a 24-pin
PLC M7F
connector each)

L
OMRON's C500-CE243 OMRON's
(Fujitsu's FCN-36@@024 XG4M-2030
Series)
L Dimensions Model
Connection 1,000 mm G79-100C
1,500 mm G79-150C
On the PLC M7F Connector
Connector pin No. pin No. 2,000 mm G79-200C
(Line A Line B) 3,000 mm G79-300C
1 11
1 1 5,000 mm G79-500C
2 12
2 2
3 13
3 3
4 14
4 4
5 15
5 5
6 16
6 6
7 17
7 7
8 18
8 8
9 19
9 9
10 20
10 10
Case mark
11 11
G79 cable
12 12
with connector (1 to 1)

G79-O@C-@ Connects the M7F


Cable with and two devices.
Connectors Suitable Output Units:
(1 to 2) C500-OD213,
C200H-OD218,
C200H-OD219, and L Dimensions For output
CQM1-OD213 A B Model
(Output Units 1,000 mm 750 mm G79-O100C-75
incorporating a 40-pin
OMRON's C500-OE243 1,500 mm 1,250 mm G79-O150C-125
connector each) (Fujitsu's FCN-36@@024
Series) a 2,000 mm 1,750 mm G79-O200C-175
3,000 mm 2,750 mm G79-O300C-275
PLC M7F 5,000 mm 4,750 mm G79-O500C-475

OMRON's
b XG4M-2030
Straight length (with no bend)

G79-Y@C Ideal for the


Cable with connection of the M7F
Crimp-style to devices L Dimensions Model
Terminals incorporating screw
terminals. 1,000 mm G79-Y100C
Suitable Output Units: 1,500 mm G79-Y150C
CS1W-OD211, and 2,000 mm G79-Y200C
CS1W-OD212
Device M7F 3,000 mm G79-Y300C
side
5,000 mm G79-Y500C
L
300
OMRON's
XG4M-2030

http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.


3
M7F
Specifications
■ Applicable EN Standards ■ Characteristics
Standards Insulation 100 MΩ min. (at 500 VDC) between each terminal and
EN61326 resistance mounting panel
EN60529 Dielectric 1,000 VAC, 50/60 Hz for 1 min between each terminal
UL61010-1 (Pending) strength and mounting panel
Noise Power terminal: ±500 V (normal mode)
■ Ratings immunity
(See note.) I/O cable:
±1,500 V (common mode)
±800 V (when the specified cable is
Rated power supply 12 to 24 VDC used)
Allowable voltage fluctuation range 90% to 110% of rated voltage Vibration Destruction: 10 to 55 Hz, 1.5-mm double amplitude
resistance 10 sweeps of 5 min each in X, Y, and Z directions
Current con- 14 mm 200 mA max. (at 12 VDC)
sumption
100 mA max. (at 24 VDC) Shock Malfunction: 300 m/s2
resistance 3 times each in 6 directions on X, Y, and Z axes
Input level Static Positive High: 9.6 V to power supply voltage
input Low: 0 to 3 V Degree of IEC IP40 (front panel only)
Negative High: 4 V to power supply voltage protection
Low: 0 to 1.5 V
Dynamic Positive High: 4 V to power supply voltage Note: Impulse conditions:
input (See note.) Low: 0 to 1.5 V Rise time: 1 ns +10% max.
Ambient temperature Operating: −10°C to 55°C (with no
Pulse width: 100 ns, 1 μs
icing or condensation) Frequency: 100 Hz
Storage: −25°C to 65°C (with no icing Polarity: Positive or negative
or condensation) Cable: OMRON's G79-100C
Ambient humidity Operating: 35% to 85% (with no icing
or condensation)

Note: Use an NPN open collector for the output of the connection
device. The data signal, however, is positive logic and the
strobe signal is negative logic.

http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.


4
M7F
Operation
■ Input Codes
Numeric Display
Positive Logic Static Input (M7F-@P@@@)
Input signal Display condition
103 digit 102 digit 101 digit 100 digit
Terminal no. R Q P O N M L K H G F E D C B A
Terminal D4 C4 B4 A4 D3 C3 B3 A3 D2 C2 B2 A2 D1 C1 B1 A1 103 102 101 100
symbol digit digit digit digit
Input signals L L L L L L L L L L L L L L L L 0 0 0 0
L L L H L L L H L L L H L L L H 1 1 1 1
L L H L L L H L L L H L L L H L 2 2 2 2
L L H H L L H H L L H H L L H H 3 3 3 3
L H L L L H L L L H L L L H L L 4 4 4 4
L H L H L H L H L H L H L H L H 5 5 5 5
L H H L L H H L L H H L L H H L 6 6 6 6
L H H H L H H H L H H H L H H H 7 7 7 7
H L L L H L L L H L L L H L L L 8 8 8 8
H L L H H L L H H L L H H L L H 9 9 9 9
H L H L H L H L H L H L H L H L a a a a
H L H H H L H H H L H H H L H H b b b b
H H L L H H L L H H L L H H L L c c c c
H H L H H H L H H H L H H H L H d d d d
H H H L H H H L H H H L H H H L e e e e
H H H H H H H H H H H H H H H H f f f f

Negative Logic Static Input (M7F-@N@@@)


Input signal Display condition
103 digit 102 digit 101 digit 100 digit
Terminal no. R Q P O N M L K H G F E D C B A
Terminal D4 C4 B4 A4 D3 C3 B3 A3 D2 C2 B2 A2 D1 C1 B1 A1 103 102 101 100
symbol digit digit digit digit
Input signals H H H H H H H H H H H H H H H H 0 0 0 0
H H H L H H H L H H H L H H H L 1 1 1 1
H H L H H H L H H H L H H H L H 2 2 2 2
H H L L H H L L H H L L H H L L 3 3 3 3
H L H H H L H H H L H H H L H H 4 4 4 4
H L H L H L H L H L H L H L H L 5 5 5 5
H L L H H L L H H L L H H L L H 6 6 6 6
H L L L H L L L H L L L H L L L 7 7 7 7
L H H H L H H H L H H H L H H H 8 8 8 8
L H H L L H H L L H H L L H H L 9 9 9 9
L H L H L H L H L H L H L H L H a a a a
L H L L L H L L L H L L L H L L b b b b
L L H H L L H H L L H H L L H H c c c c
L L H L L L H L L L H L L L H L d d d d
L L L H L L L H L L L H L L L H e e e e
L L L L L L L L L L L L L L L L f f f f

http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.


5
M7F
Dynamic Input (M7F-@D@@@)
Input signal Display condition
Terminal no. D C B A K L M N O
Terminal D C B A S0 S1 S2 S3 S4 104 103 102 101 100
symbol digit digit digit digit digit
Input signals L L L L L H H H H * * * * 0
L L L H H L H H H * * * 1 *
L L H L H H L H H * * 2 * *
L L H H H H H L H * 3 * * *
L H L L H H H H L 4 * * * *
L H L H L H H H H * * * * 5
L H H L H L H H H * * * 6 *
L H H H H H L H H * * 7 * *
H L L L H H H L H * 8 * * *
H L L H H H H H L 9 * * * *
H L H L L H H H H * * * * a
H L H H H L H H H * * * b * * The data of S0 to S4 when S0 to S4
H H L L H H L H H * * c * * are high before S0 to S4 become
H H L H H H H L H * d * * * low will be held and displayed. Refer
to Operation Timing (Input Signal
H H H L H H H H L e * * * * Timing) on page 12 and Operation
H H H H L H H H H * * * * f Chart on page 12 for details.

Unit Display Zero Suppression Function


The displays are lit when voltage is supplied to the power supply The Unit has a function for blanking (i.e., turning OFF the display) to
terminals (positive and negative terminals). not display 0 when the leftmost digits are zero. When DP (decimal
point) has been displayed using the DIP switch, the digits to the left
Minus Symbol and Decimal Point of the decimal point display digit will be blank as shown in the
following figure.
The DIP switch is used for minus symbol and decimal point settings
as shown in the following table. Fourth Third Second First
digit digit digit digit
Display Model DIP switch function
contents
No decimal point is designated.
Three digits M7F-3@@@F The second, third, and fourth digits
Numerals are blank.
and minus
symbol
There is a decimal point between
Three digits M7F-3@@@T the first and second digits.
DP The third and fourth digits are
Numerals blank.
and unit
There is a decimal point between
the third and second digits.
Four digits M7F-4@@@ DP The fourth digit is blank.
Numerals
only
There is a decimal point between
the fourth and third digits.
Four digits M7F-4@@@F DP All digits are displayed.
Numerals Note: The zero suppression function is normally operating.
and minus
symbol

Four digits M7F-4@@@T


Numerals
and unit

Five digits M7F-5@@@


Numerals
only

Note: The minus symbol and decimal point are always lit when the
corresponding pins of the DIP switch are set to ON.

http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.


6
M7F
■ Terminal Arrangement/Functions
Terminal Arrangement
XG4A Connector XG4A Connector
Static Input Model Dynamic Input Model

Signal input Power supply Power supply

Power supply 0 V
Power supply 0 V

Power supply (+)


Power supply (+)
Signal input

Data 20 × 102
Data 21 × 102
Data 22 × 102
Data 23 × 102
Data 20 × 103
Data 21 × 103
Data 22 × 103
Data 23 × 103

Strobe 100
Strobe 101
Strobe 102
Strobe 103
Strobe 104
Power supply (+)
DIP Switch
Power supply (−) Polarity guide
Terminal name

Terminal guide

Data 20 × 100
Data 21 × 100
Data 22 × 100
Data 23 × 100
Data 20 × 101
Data 21 × 101
Data 22 × 101
101

Power supply (+)

Power supply 0 V
Power supply (+)
Power supply 0 V

Data 20
Data 21
Data 22
Data 23
Case Case

×
mark mark

23
Data
Signal input

Signal input Power supply Power supply

Note: Circled numbers are for the user's convenience. When preparing a socket, pay attention
when wiring the terminals to the direction of the polarity guide.

Terminal Functions
Input method Terminal Name Function
symbol
Static input A1 First digit (100) A1 (20) The numeral or symbol corresponding to the binary code signal will be
B1 data input B1 (21) displayed as the first digit (100).
C1 C1 (22)
D1 D1 (23)
A2 Second digit (101) A2 (20) The numeral or symbol corresponding to the binary code signal will be
B2 data input B2 (21) displayed as the second digit (101).
C2 C2 (22)
D2 D2 (23)
A3 Third digit (102) A3 (20) The numeral or symbol corresponding to the binary code signal will be
B3 data input B3 (21) displayed as the third digit (102).
C3 C3 (22)
D3 D3 (23)
A4 Fourth digit (103) A4 (20) The numeral or symbol corresponding to the binary code signal will be
B4 data input B4 (21) displayed as the fourth digit (103).
C4 C4 (22)
D4 D4 (23)
+V Power supply Power supply and output terminal
0V Power supply Power supply 0-V output terminal (GND)
Dynamic input A Data input A (20) Displays the numeral or symbol corresponding to the binary code signal.
B B (21)
C C (22)
D D (23)
S0 Control input S0 (100) Designates the digit to be displayed. Each digit will maintain the previous
S1 S1 (101) value when this signal is input.
S2 S2 (102)
S3 S3 (103)
S4 S4 (104)
+V Power supply Power supply and output terminal
0V Power supply Power supply 0-V output terminal (GND)

DIP Switch Function


The DIP switch is used for symbol and decimal point settings. Refer to Terminal Arrangement, above, for details.

http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.


7
M7F
■ Block Diagram
Note: Circled numbers are the connector pin numbers.

Static Input Method Dynamic Input Method

External External
power Switching Switching
regulator power
supply input supply input regulator

Power supply Power supply


output into output into
the PLC the PLC

A1 to D1 to
Input circuit

decoder circuit

Input circuit

decoder circuit
Driver circuit/

Driver circuit/
Signal A2 to D2 to
Signal
input A3 to D3 to input
A4 to D4 to

LED display
elements
LED display elements

Input circuit
Strobe
Signal Input

Signal Positive Logic Input Method Signal Data signal input


Input Input
Circuit 57 kΩ Circuit
Signal input
7 kΩ
29 kΩ
0.033 μF 10 kΩ
Signal input

0.033 μF

Negative Logic Input Method Strobe signal input

7 kΩ
29 kΩ 7 kΩ
Signal input 29 kΩ
Signal input
0.033 μF
0.033 μF

http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.


8
M7F
■ External Connections
Refer to Block Diagram on page 8 and Terminal Arrangement on
page 7 for external connections for the M7F according to the signal
input method.

PLC Connections
• Refer to your PLC operation manual before connecting the PLC.
• The M7F connects to the PLC without using any external resistor.
• It is necessary to select the correct input method of the M7F
according to the output method of the PLC Output Unit. Refer to
Connectable PLCs on page 2 for details on the selection of the
correct input method.
• A PLC Dynamic Output Unit can be used to save wiring. Use a
dynamic input model (M7F-@D@@@).

With PLC Static Output Unit


1. M7F-@P@@@ Static Positive Logic Input Model
Connected to C500-OD212 Output Unit

PLC

Terminal Termi-
name nal No.

Circuit Configuration

PLC

A to D

0V 0V

PLC Output
Unit
Power
DC power supply
supply (+) input
12 to 24 VDC Power
supply
(0 V) input

Note: 1. Use the M7F positive logic input model if the PLC Output Unit has PNP output.
2. The PLC connects to the M7F with ease via the enclosed G79-Y@C Cable (with
connectors, sold separately).

http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.


9
M7F
2. M7F-@N@@@ Static Negative Logic Input Model
1. Connected to C500-OD213 Output Unit

PLC

Terminal Termi-
name nal No.

Circuit Configuration
PLC

A to D
PLC Output
Power
Unit DC power supply
supply (+) input
12 to 24 VDC Power
supply
(0 V) input

Note: The PLC connects to the M7F with ease via the G79-@C Cable (with connectors, sold separately).

2. Connected to C200H-OD215 Output Unit

PLC

Terminal Termi-
name nal No.

Circuit Configuration

PLC

A to D
Power
DC power supply
supply (+) input
12 to 24 VDC Power
supply
(0 V) input
PLC Output
Unit Fuse

Note: 1. If the C200H-OD215 is used as a Static Output Unit, the switches on the rear panel of the PLC must be set as described in
the following table.
SW1 (static output mode) OFF
SW2 OFF
SW3 OFF
SW4 OFF
SW5 (negative logic output) OFF
SW6 OFF
Refer to your PLC operation manual for details.

2. A G79-@C Connecting Cable (with connectors, sold separately) can be used to easily connect the PLC to the M7F.

http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.


10
M7F
With PLC Dynamic Output Unit
M7F-@D@@@ Dynamic Input Model
Connected to C200H-OD215 Output Unit
PLC

Terminal Termi-
name nal No.

Circuit Configuration

PLC

A to D
S0 to S4

Power
DC power supply
supply (+) input
12 to 24 VDC Power
supply
(0 V) input
PLC Output Fuse
Unit

Note: 1. If the C200H-OD215 is used as a Dynamic Output Unit, the switches on the rear panel of the PLC must be set as described
in the following table.
SW1 (dynamic output mode) ON
SW2 OFF
SW3 OFF
SW4 OFF
SW5 (positive logic output) ON
SW6 OFF Refer to your PLC operation manual for details.

2. A G79-@C Connecting Cable (with connectors, sold separately) can be used to easily connect the PLC to the M7F.
3. An eight-bit data signal is allocated to each strobe signal of the C200H-OD215 Dynamic Output Unit. On the other hand, each
strobe signal is input only to the rightmost four bits of the M7F. Thus the following program must run.
1. Status before PLC Program Runs (Data Storage Status) 2. Example of PLC Program Operation
(Refer to your PLC operation manual for details.)
Relay no. 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Data no. 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Transfers the first digit's data of word 005 to the
Word 005 4 3 2 1
no. first digit of word 100.
006 5
007 Transfers the second digit's data of word 005 to
008
the third digit of word 100.
Transfers the third digit's data of word 005 to
Note: Word numbers and data are examples. the first digit of word 101.
Transfers the fourth digit's data of word 005 to
M7F 's display the third digit of word 101.
Transfers the first digit data of word 006 to the
first digit of word 102.

3. Status after PLC Program Has Run (Data Storage Status)

Relay no. 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Data no. 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Word 100 2 1
no.
101 4 3
102 5
103

Note: Word numbers and data are examples.

M7F 's display

http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.


11
M7F
Operation
■ Operation Timing (Input Signal Timing)
Dynamic Input Method (M7F-@D@@@)
Data input
signals A to D Pulse duration (tw) 1.5 ms
ts th
Hold time (th) 0.75 ms
Strobe input H Data latch Data read Data latch
(S0 to S4) L Setup time (ts) 2.25 ms
tw

■ Operation Chart
Dynamic Input Method (M7F-@D@@@)
The following example shows the relationship between each input terminal and the display condition. (Example: 5-digit)

Data input Data contents 5 3 1 8 9


signals
(A to D)

Data read
1st digit H Data input signals
Data latch Data latch
(S0) L

2nd digit H Data read


Strobe input signals

Data latch Data latch


(S1) L

3rd digit H Data read


Data latch Data latch
(S2) L

4th digit H Data read Strobe input signals


(S3) Data latch Data latch
L
Data read
5th digit H
Data latch
(S4) L

1st-digit display change 2nd-digit display change 3rd-digit display change 4th-digit display change A numeric value is
Display 5th-digit display change
displayed one digit at a
condition time via data signals A
to D.

http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.


12
M7F
Dimensions
Note: All units are in millimeters unless otherwise indicated.

M7F-@@1@@ M7F-4@1@F 4
67.5
50 (13.5)

LED
10°
30.4

14.2
M7F-4@1@T Panel Cutout
(Single Mounting)
The M7F-4@1@ is 67 +0.6
−0.4
7.8
illustrated.
31
M7F-3@1@F

M7F-5D1@
(Side-by-side Mounting)
72
68 (72n−5) +0.6
−0.4
66

31 +0.6
−0.4
M7F-3@1@T
36 29 14.22

7 min.

M7F-4@1@ Panel thickness: 1 to 6 mm


n: Number of Units mounted

66.5

http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.


13
M7F
Safety Precautions
!CAUTION ■ Precaution for Correct Use
Tighten the screws on the terminal block securely using
the recommended tightening torque of 0.5 N·m. Loose Wiring
screws may occasionally cause fire, resulting in minor or • Do not tighten the power supply terminals with excessive force
moderate injury, or damage to the equipment. when wiring. Doing so may damage the terminals. Tighten each of
them to a torque of 0.29 to 0.49 N·m.
■ Precautions for Safe Use • Do not impose excessive force on the rear panel when tightening
the terminals of the M7F or connecting a connector to the M7F.
• Do not use or store the product in the following locations. • When tightening the terminals of the M7F or connecting a
• Locations subject to direct radiant heat from heating equipment connector to the M7F, hold the displays by hand, otherwise the
displays may protrude from the case.
• Locations where the product may come into contact with water,
oil, or salt water
Environment
• Locations subject to direct sunlight
When using the M7F in places with dust, metal powder, or sprayed
• Locations where dust or corrosive gases (in particular, sulfuric oil, be sure to take appropriate measures so that no dust, metal
or ammonia gas) are present powder, or sprayed oil will penetrate the interior of the Display Units.
• Locations subject to extreme temperature changes
• Locations where icing or condensation may occur Mounting
• Locations subject to excessive shocks or vibration • When panel-mounting, make sure that the side of the case marked
"TOP" is upward.
• Locations subject to temperatures or humidity outside the
• When panel-mounting, do not press the central part of the displays,
specified range
otherwise the displays may be damaged. Press the flange part.
• Locations outdoors or exposed to wind or rain
• Locations subject to static electricity or noise Connections
• Do not use the product in locations subject to temperatures outside • If power will be supplied to the M7F from the PLC's I/O service
the specified ranges or in locations subject to condensation. If the power supply, make sure that the current consumption of the M7F
product is installed in a panel, be sure that the temperature around does not exceed the rated capacity of the service power supply.
the product (not the temperature around the panel) does not go • It is recommended to supply power to the M7F from a dedicated
outside the specified range. The life of components is dependent DC power supply in order to protect the PLC from being damaged.
on the temperature. The life of components shortens when the • When using a controller other than the PLC or another company's
temperature rises, and it lengthens when the temperature falls. The PLC, be sure to check the terminal arrangement of the connector of
life of components can be lengthened by lowering the temperature the controller or the PLC. The terminal arrangement of OMRON's
inside the product. cables incorporating connectors corresponds to that of the PLC.
• Do not install the product near devices generating strong high
frequency waves or surges. When using a noise filter, check the Removing Color Plate
voltage and current and install it as close to the product as
possible. There is a gap (with a width of approximately 1 mm) between the
• Do not touch terminals or perform wiring while power is supplied to case and color plate on the left and right sides. To remove the color
the product. Doing so may result in injury or malfunction. plate, insert a flat-blade screwdriver into either one of the gaps and
move the color plate upwards.
• Do not touch the terminals while power is being supplied. Doing so
may result in product failure or malfunction. Case
• When tightening the terminals or connecting connectors, support Color plate
the product with one hand to prevent it from being pushed out of the
front of the panel.
• Wire to the correct terminal number. Incorrect wiring may result in
damage to or burning of components.
• Be sure power supplies and power lines for control power supply
and inputs have appropriate specifications. Not using power
supplies and power lines with appropriate specifications may result
in malfunction, burning, or electric shock.
• Do not attempt to disassemble, repair, or modify the product. Doing
so may occasionally result in minor or moderate injury.
• Do not allow pieces of metal, wire clippings, or fine metallic Replacing Unit Plate
shavings or filings to enter the product. Doing so may occasionally • Remove the unit plate with a pair of tweezers.
result in fire or product failure.
• Before pasting a unit plate to the plate holder, remove the ground
• For DC input, use an SELV power supply with overcurrent paper from the unit plate. Paste the unit plate to the plate holder so
protection. Specifically, use an SELV power supply with double or that the symbol mark or character(s) of the face plate will be on the
reinforced insulation between input and output, and an output bottom side (i.e., the decimal-point side) of the M7F.
voltage of 30 Vrms with 42.2 V peak or 60 VDC maximum.
Recommended power supply: S8VS-06024@ (OMRON product) TOP display panel
Unit plate

Plate holder

http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.


14
M7F
Attaching Color Plate
Insert the projecting parts of the color plate into the square holes of
the case to attach the color plate to the case.

Color plate projecting part (There are


four color plate projecting parts.)

Square hole (There are four square


holes.)

DIP Switch Settings


The DIP switch can be set with the tip of a ball-point pen or small
screwdriver. Do not use anything that has a sharp edge (e.g.,
tweezers) to set the DIP switch.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.


To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

In the interest of product improvement, specifications are subject to change without notice.

http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.


15
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

Warranty and Limitations of Liability


WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR


FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE
HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL
LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR
STRICT LIABILITY.

In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the product.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety
equipment, and installations subject to separate industry or government regulations.

• Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased product.

DIMENSIONS AND WEIGHTS


Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

ERRORS AND OMISSIONS


The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent
the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

COPYRIGHT AND COPY PERMISSION


This catalog shall not be copied for sales or promotions without permission.

This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this
catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety.

2007. 11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.

You might also like