Sumo Pump: User and Maintenance Manual
Sumo Pump: User and Maintenance Manual
Sumo Pump: User and Maintenance Manual
Guarantee
CONTENTS
1. INTRODUCTION
2. GENERAL DESCRIPTION
3. IDENTIFICATION OF THE MACHINE
4. TECHNICAL CHARACTERISTICS
5. PUMP COMPONENTS
6. UNPACKING AND INSTALLATION
7. INSTRUCTIONS FOR USE
8. PROBLEMS AND SOLUTIONS
9. MAINTENANCE PROCEDURES
10. DISPOSAL
11. INFORMATION ABOUT ORDERING
12. DIMENSIONS
13. HANDLING AND TRANSPORT
14. PRECAUTIONS FOR USE
15. CONTRAINDICATIONS FOR USE
16. GUARANTEE
17. DECLARATION OF CONFORMITY
18. DISTRIBUTORS
Certification
This user and maintenance manual relates to the Sumo pump. Using this pump means t hat oils and greases can be
distributed within lubrication systems even at high pressures of up to 400 bar (5880 psi).
The latest version may be obtained from the Technical-Commercial Office, or by consulting our web site
http://www.dropsa.com.
The pump subject of this manual must be used by qualified personnel with basic hydraulic and electrical knowledge.
This user and maintenance manual contains important information about protecting the health and safety of the
personnel who intend to use this apparatus. You must read and look after it carefully, making sure that it is available
at all times for the operators who intend to consult it.
2. GENERAL DESCRIPTION
The Sumo series of lubrication pumps may be adapted to many uses without making any mechanical changes even
after it has been installed. In fact, by making a selection from a set of components which are fully compatible and
easy to assemble, the pressure, quantity of lubricant delivered, actual type of lubricant or type of distribution can be
altered.
This construction technique is essentially based on the following modules:
· Electric motor
· Pump body with integrated reducer
· Two pumping elements
· Reservoir
· Valves and outlet unit (inverter, pressure adjustment valve, etc.).
There is only one bearing structure for all versions, with the dual pumping element constituting the essential module.
The pump unit possesses one single output, because the deliveries from the two pumping elements flow into a
manifold unit.
Two types of tank for grease and two for oil with different volumes (of 30 or 100 kg) with stirring paddle and level
indicators can be arranged on the pump body.
The pump is controlled by normal electrical apparatus which is able to effect inversion and perform the programmed
cycles.
The Sumo electric pump is fully protected against the external environment and can operate without difficulty under
the most severe environmental conditions.
Photo 1 Photo 2
Sumo Pump trolley mounted 30 Kg metal reservoir; the system is complete with electrical control equipment that
allows the pump motor to be switched off when maximum pressure has been reached and dispensing lever is
closed.
3/ 31
2.2 TRANSPARENT RESERVOIR VERSION
Sumo Pump 80 Kg with transparent reservoir made of polyethylene for special applications.
A B C D E F
780 734 630 580 1410 Ø335
PLASTIC GREASE
RESERVOIR
F E
148,5
B E
A Ø14
606,5
100
4/ 31
3. IDENTIFICATION OF THE MACHINE
On the front part of the pump tank there is a plate which indicates the product code, the supply voltage and the basic
characteristics.
4. TECHNICAL CHARACTERISTICS
Technical characteristics
Max. pressure 400 bar
3
400 cm / min (24 cu. in/min)
Outlet delivery 3
(2 x 200 cm (12 cu. in) pump modules )
Working temperature da - 5° C a + 50° C (da 23° F a +122° F)
Working humidity 90% max
Mineral oil lubricants
Viscosity at wo rking
Min. 32 cSt
temperature
Grease lubricants
Viscosity at wo rking
NGLI 2 Max.
temperature
Degree of protection IP 55
Three phase
Power 0.75kW
Protection IP55 class B
Electric moto r
Voltage: 230-400 Volt ± 5% 50 Hz
240-440Volt ± 5% 60 Hz
S1 continuous service.
N.B.: do not supply the machine with voltages and pressures different from those indicated
on the plate.
Standard grease pump (dual line) Standard oil pump (dual line)
5/ 31
Single outlet grease pump (opt ion). Single outlet oil pump (option).
Grease pump (options: dual line, electropneumatic Oil pump (options: dual line, electropneumatic
inverter). inverter).
6/ 31
5. PUMP COMPONENTS
The pump has two fixed delivery standard pumping elements (200 cm^3/ min for each pumping element). A piston
slides inside the body of the pumping element coupled to the latter by a lapping process. The seal between the
piston and the pumping body is of a dry type, with no gasket provided between the two. The pumping element
retention valve is of the tapered seal type. This solution is able to guarantee an optimum seal for the system at high
operating pressures (max. pressure of 400 bar). The pumping elements are assembled on the manifold unit with a
threaded attachment, which facilitates its assembly/ dismantling.
The pump has endless screw-worm wheel working kinematics with a transmission ratio of 1/40. The screw is made
from special steel with high mechanical resistance, which gives it optimum flexible rigidity. To guarantee high
resistance to wear, the screw has been subjected to Tenifer wear-resistant treatment. The screw is supported by
oblique contact ball bearings, duly preloaded, to reduce working clearance. The worm wheel is made of bronze alloy
for gear systems, particularly suitable for making the pump run quietly. The worm wheel shaft is made of special high
resistance steel which gives the pump better reliability and durability.
5.3 INVERTORS
Code Description
Series 0083420 Interchangeable electromagnetic inverter (mounted as standard on SUMO pump
Series 0083400 Electromagnetic inverter
Series 0083450 Electropneumatic inverter
Spare parts
Current
Code Description Power (W)
(A)
3150011 Electromagnet 24V DC 7 170
3150012 Electromagnet 110V AC 50/60 Hz 2 206
3150013 Electromagnet 230V AC 50/60 Hz 1 176
3133262 Seal kit
GENERAL NOTE FOR ALL INVERTERS: It is advisable to plan a delay in the de-energizing of the
electromagnets from 2 - 5 sec. to allow complete inversion in relation to the closing time of the
pressure gauge at the end of the line.
7/ 31
5.3.1 Interchangeable electromagnetic inverter (code 0083420 mounted on standard pump)
The standard pump is prepared for dual line function, with an electromagnetically controlled inverter being
assembled as standard. The inverter can be replaced if it is not working efficiently, without disconnecting the two line
pipes (of an interchangeable type). This is able to reduce maintenance times and the relating installation shutdown.
Photo 3
This version means that the inverter can be replaced
without disconnecting the line pipes. A solution of this
type offers the following advantages:
Photo 4
The main parts of the inverter are:
8/ 31
5.3.3 Electropneumatic inverter (code 0083450 option)
Photo 5
The main parts of the device are:
· See point 5.3.2;
· two simple effect pneumatic actuation cylinders,
controlled by a 5/ 2 type electrovalve.
Spare electrovalves
Code Description
3155154 Solenoid 24V DC
3155155 Solenoid 24V AC 50/60 Hz
3155156 Solenoid 110V AC 50/60 Hz
3155157 Solenoid 230V AC 50/60 Hz
Photo 6
Pump group unit
Bypass pressure
adjustment nut
The pump has a pressure control valve, mounted
on the manifold unit on the right side of the pumping Ch 34
elements. The valve can be easily dismantled for
inspection if required. It is calibrated by turning the
bypass pressure adjustment nut:
· clockwise (increase of pressure)
· anticlockwise (decrease of pressure)
9/ 31
Code Description
3191311 Pressure 100 ÷ 450 bar (1470 ÷ 6615psi)
3191314 Pressure 50 ÷ 200 bar (735÷ 294 0 psi) on request
The standard pump has two pumping elements with fixed delivery (Image 1). On request it is possible to have a
solution with variable delivery (Image 2). The pump can offer variable delivery by replacing a pumping element with
fixed delivery with one with variable delivery.
The main parts of the pumping element with variable delivery are:
· External body of the pumping element assembled with seal threading on the manifold group;
· Internal body of the pumping element equipped with delivery adjustment with threaded screws;
· Piston;
· Non-return valve manufactured with tapered cone seal system;
· Spring which guarantees contact between the piston and the control excentric gear.
10/ 31
Fixed delivery pumping element code 0295040 Variable delivery pumping element code 0295060
Image 1 Image 2
Delivery is adjusted by unscrewing (reducing delivery) or tightening (increasing delivery) the internal pumping
element: each complete turn corresponds to an 11.5% change in delivery. There are two references on the fixed and
mobile pumping element bodies (Photo 8) which allow identification of rotation at every ¼ turn (90°). The internal
pumping element possesses a threaded adjustment of M36x2: each complete turn corresponds to an adjustment of
the pumping element’s stroke of 2 mm. We use the reference height obtained with calibration, between the exterior
of the fixed pumping element and the exterior of the internal pumping element (height X). We use Y to indicate the
actual displacement of the internal pumping element (Y=13-X).
Photo 7 Photo 8
Image 3
11/ 31
5.7 MAXIMUM AND MINIMUM GREASE LEVEL INDICATORS
Code Description
0295100 Maximum visual level kit (float).
0295120 Minimum capacitive level kit per tank kg 30 (68.1 lb.)
0295110 Minimum capacitive level kit per tank kg 100 (100.02 kg.)
3289166 Capacitive probe
The minimum level is produced by a capacitive probe, positioned on the end of a pipe mounted on the tank cover.
The capacitive probe is normally closed. When it reaches the minimum level the probe indicates a lack of lubricant.
To make the solution valid for NLGI2 grease as well, the capacitive probe interfaces with the scraper whose function
is to clean the lower face of the grease probe. If the capacitive probe is replaced then it must be recalibrated (see
calibration procedure).
The minimum level contact is indicated by a light signal on the control panel. In addition it controls any command for
the pump to aut omatically refill the tank.
The phase for loading the lubricant into the tank is carried out by the operator, with an appropriate pump. Once the
maximum level of lubricant has been reached, the small rod which indicates that the tank is full intervenes.
Code Description
0295100 Maximum visual level kit (float).
0295033 Maximum visual level float
0295150 Level float kit for 30 kg tanks (68.1 lb.) (minimum and maximum level)
0295160 Level float kit for 100 kg tanks (68.1 lb.) (minimum and maximum level)
A probe rod with dual float mounted on t he pump cover provides a reading of the minimum oil level (reserve) and the
maximum level (which allows the automatic refilling of the tank to be halted).
The minimum level contact is indicated by a light signal on the control panel. In addition it controls any command for
the pump to aut omatically refill the tank.
Four tanks are provided with a capacity of 30 and 100 kg. (22 – 66.1 – 220.4 lb) two for oil and two for grease.
The tanks have a stirring paddle and scraper as standard, and they must not be dismantled when they are being
assembled and replaced. Under the stirring paddle a galvanized steel mesh with 0.5 mm holes (0.02 in.) is provided
as standard. In this way the pump is protected from any foreign bodies which might be inadvertently present during
the tank refilling process.
12/ 31
5.8 PRESSURE GAUGE
The pressure gauge is of the glycerin filled type, so it is protected from any pressure leaks which might damage its
functioning. It is mounted directly in the manifold group (positioned on the front of the pump).
Code Description
3292078 1000 bar ( 0 -14.700 psi)
“DROPSA” electrical control panel has been designed to provide a system complete with all the controls necessary
for automatic functioning controlled by safety signals from centralized lubrication installations. The primary voltage is
400 VAC and 50 Hz, the other voltages are on request.
No pump assembly operations are envisaged. The pump is fixed on a metal pallet, which allows safe handling using
a transpallet or forklift truck. This pallet has been designed so that it can be installed in the installation, being
equipped with 4 (four) holes of Ø 14 mm suitable for fixing to the floor. Provide adequate space (as shown on the
installation diagram) to avoi d abnormal posture or possible impact. Then, as described previously, the pump must be
connected hydraulically to the machine and then connected to the control panel.
13/ 31
7. INSTRUCTIONS FOR USE
Damage to the supply cable and housing may involve contact with live parts at high voltage and
consequently fatal danger:
· Check the integrity of the supply cable and the unit prior to use;
· If the supply cable or the unit is damaged, do not start up the syst em!
· Replace the damaged supply cable with a new one;
· The unit can be opened and repai red only by specialist personnel;
· In order to prevent the danger of electrocution due to direct or indirect contact with live parts the electric supply
line must be adequately protected by an appropriate magnetothermal differential switch with threshold of
intervention of 0.03 ampere and max intervention time of 1 second;
· The interruption power of the switch must be £ 10 kA and rated current In = 6 A.
· The pump must not be used when submerged in fluids or in a particularly aggressive or explosive/inflammable
atmosphere unless prepared in advance for this purpose by the supplier;
· to fix the pump correctly check the pitch dimensions shown in the figures in chapter 12;
· Use safety gloves and goggles as indicated in the safety sheet for the lubrication oil;
· Do NOT use lubricants which are aggressive towards NBR gaskets, and if in doubt consult the Dropsa SpA
technical office which will supply a detailed list of the recommended oils;
· Do not ignore dangers to health and comply with health and safety regulations;
· Warning! All the electric components must be earthed. This applies to both the electric components, and to the
control devices. To this end make sure that the earth wire is connected correctly. For safety reasons the earth
conductor must be approximately 100 mm longer than the phase conductors. If the cable is accidentally
removed, the earth terminal must be the last one to be removed.
7.3 USE.
7.4.1 Pressu re
It is possible to adjust working pressure by rotating the bypass screw clockwise to increase pressure or anticlockwise
to reduce pressure. During this operation pay attention to the pressure gauge positioned on the edge of the pump.
14/ 31
7.4.2 Pro cedure for calibrating the capacitive probe
Before being assembled the capacitive probe must be calibrated in accordance with the following sequence:
1. connect the sensor electrically;
2. immerse the sensor in the lubricant, down to half of its length;
3. remove the sensor from the lubricant until it skims the surface of the lubricant;
4. at this point there can be two possible types of operation:
· the sensor status does not change: its sensitivity must be reduced (by acting on the screws for adjusting
sensor sensitivity) until its state of excitation is reached
· if its status changes, the sensor already possesses the correct sensitivity
5. after checking that the sensor has been correctly read, the sensor reading must be repeated at least three times
6. Tighten the capacitive probe on the probe carrier rod, complying with the following assembly height:
· 450 mm (from below the cover up to the lower surface of the sensor) for a 30 kg tank
· 900 mm (from below the cover up to the lower surface of the sensor) for a 100 kg tank
Operating instructions for the capacitive probe (model SC18M-C5 PNP NO + NC)
Image 4
Image 5
They are sensors which are amplified in continuous current and which incorporate, in
addition to the oscillator, the outlet amplifier. They are supplied with 4 wires with an
antivalent function in the NPN or PNP versions. In this operation the sensors offer as
standard characteristics protection against permanent short circuit of the load, absolute
safety against inversion of polarity and protection from the peaks produced by
disconnecting inductive loads. They can be supplied together with model ALNC – ALTP
feeders. They are compatible with programmable controller inputs.
15/ 31
7.4.3 Procedure for calibrating the laser probe
The laser probe possesses a representative and programming display mounted on board. It is possible to operate in
analogue mode (w ith signal from 4 to 20 mA) or in digital mode (two outputs and four intervention thresholds).
We attach a table showing the calibration parameters for the laser probe, for 30 and 100 kg tank.
Image 6
LASER PROBE CALIBRATION
N.B.: In the 30 kg pump tank at minimum absolute level there is still a reserve of 7 kg.
In the 100 kg pump tank at absolute minimum level there is still a reserve of 15 k.g
Operating instructions for the IFM laser probe model O1D100 (code 3289172)
Image 7
16/ 31
17/ 31
Instructions for calibrating the Laser Probe O1D100
1. Press the MODE ENTER key 7 times: EF. appears on the Display.
2. Press the SET key.
3. Press the MODE ENTER key 5 times: diS. appears on the Display.
4. Press the SET key. d3. appears on the Display.
5. Keep the SET button pressed down for 5 sec.
6. When the wording on the Display no longer flashes, press SET once.
7. rd1. appears on the Display.
8. Press MODE ENTER once.
9. Check that the Display wording has rotated by 180°.
Calibrate outlet 1 (OUT 1) operating with window nsP1 (B) & fsP1 (D) (see Calibration table for Laser probe)
1. Press the MODE ENTER key once: OU1 appears on the Display.
2. Keep the SET button pressed down for 5 sec.
3. When the wording on the Display no longer flashes, press SET twice until Fno appears on the Display.
4. Press the MODE ENTER key once: nsP1 appears on the Display.
5. Keep the SET button pressed down for 5 sec.
6. When the wording on the Display no longer flashes, press SET once.
7. The value of the height read appears on the Display.
8. Press the SET button until the desired height appears.
9. Press the MODE ENTER button once and t he height set is memorised.
10. Press the MODE ENTER key once: fsP1 appears on the Display.
11. Repeat the previous points from N° 5 to N° 9.
Calibrate outlet 2 (OUT 2) operating with window nsP2 (A) & fsP2 (C) (see Calibration table for Laser probe)
1. Press the MODE ENTER key once: OU2 appears on the Display.
2. Keep the SET button pressed down for 5 sec.
3. When the wording on the Display no longer flashes, press SET 4 times until Fno appears on the Display.
4. Press the MODE ENTER key once: nsP2 appears on the Display.
5. Keep the SET button pressed down for 5 sec.
6. When the wording on the Display no longer flashes, press SET once.
7. The value of the height read appears on the Display.
8. Press the SET button until the desired height appears.
9. Press the MODE ENTER button once and t he height set is memorised.
10. Press the MODE ENTER key once: fsP2 appears on the Display.
11. Repeat the previous points from N° 5 to N° 9.
18/ 31
7.4.4 Procedure for calibrating the ultrasound probe model ZWS-70/CI/QS (code 3289173)
Before being assembled the probe must be calibrated in accordance with the following sequence:
1. electrically connect the sensor (following the electric diagram shown below);
2. keep the sensor button pressed down until the two LED (green and yellow lights) flash together;
3. position it in front of the minimum absolute level to be read, entering the height by releasing the button (the two
LEDs display a fixed light);
4. press the button for 3 or 4 seconds (the probe has acquired the Minimum absolute level);
5. keep the sensor button pressed down until the two LED (green and yellow lights) flash together;
6. position it in front of the maximum absolute level to be read, entering the height by releasing the button (the two
LEDs have a fixed light);
7. press the button for 3 or 4 seconds (the probe has acquired the Maximum absolute level);
8. In this way the sensor is calibrated.
N.B.: green Led on indicates that the probe is supplied. Yellow Led on indicates operating mode for reading.
We attach a table with the calibration parameters for the ultrasound probe, for 30 and 100 kg tanks.
Image 8
N.B.: In the 30 kg pump tank at the minimum absolute level there is still a reserve of 7 kg.
In the 100 kg pump tank at the minimum absolute level there is still a reserve of 15 kg.
Photo 9
Image 9
19/ 31
Window setting:
START
END
Wait 10 sec.
END
20/ 31
Re-setting to factory settings:
START
Remove power.
Press the button for about 13 sec. while the green LED is constant.
END
Below is a diagnostic table showing the main faults, the probable causes and the possible solutions.
In the event of doubts and/or problems which cannot be solved, do not proceed to look for the fault by dismantling
parts of the machine, but contact the Dropsa Technical Office.
Internal gasket between pumping element and Replace the gasket (code 3190489).
manifold unit broken.
21/ 31
Fault Cause Solution
No signal indicating Incorrect adjustment of minimum level. Check the correct functioning of the level
minimum level when probe in the following way:
there is no lubricant in
the tank. Dismantle the minimum level unit and
recalibrate the capacitive probe.
Selection of minimum Incorrect adjustment of minimum level. The light on the control panel is still on:
level, with lubricant check the electric connection and, if
below the minimum necessary, replace the capacitive probe.
and pump w orking.
Lubrication installation accessories
METERING UNIT Metering unit small piston jammed. Replace the metering unit with another
AG6 one having the same characteristics.
However it is advisable to make sure that
Alarm signal indicating the metering units have been correctly
non-delivery of assembled, particularly with regard to
lubricant. The small fixing. Over-locking of the fixing screws
rods visible inside the may damage the met ering unit and cause
metering unit turrets the small piston to jam.
must move
sequentially up and Piping between metering unit outlet and point Remove the outlet pipe and check to see
down and activate the requiring lubrication obstructed. if the metering unit is delivering lubricant.
control microswitch
when the pump is Pressure on the line too low (the lubricant is Change the pressure control valve
working. If this is not not delivered by any outlet or only by a few adjustment (bypass) or the adjustment of
the case the two outlets). the control pressure gauge (and of line).
outlets or the single
outlet of that metering Metering unit arranged for two outlets by used Check that, when one single outlet is
unit will not deliver for only one outlet. used, the right pad is assembled and that
lubricant. the other outlet is sealed.
See instruction sheet for AG6 metering
units.
END OF LINE
PRESSURE GAUGE
The pressure gauge is Electrical connection incorrect. Check the electrical connection.
not sending the signal
to the electric
command and control
panel.
The pressure gauge Incorrect adjustment of the control pressure Reduce the pressure gauge calibration
sends the signal gauge. The pressure value set is too high and pressure until an electrical contact is
before the end of the the pressure adjustment valve (bypass) obtained.
lubrication cycle. intervenes before the pressure gauge can be
activated.
Incorrect adjustment of the control pressure Increase the pressure gauge calibration
gauge. The pressure value set is too low. valve. The optimum calibration value is
the one which allows a pressure of 50-70
bar (735 – 1029 psi) at the end of the
lubrication line.
22/ 31
9. MAINTENANCE PROC EDURES
Use the individu al protective devices needed to avoid contact with mineral oil or grease.
Regular inspection
The following regular checks must be carried out:
Check
the lubrication status 1000 hours
Cleanliness of the loading and suction filter 4000 hours
The machine does not require any special equipment for any checking and/or maintenance activity, however the
recommendation is to use suitable equipment which is in a good condition in order to avoid causing damage to
persons or machine parts (according to current regulation).
If necessary clean the tank paying due attention (when the machine is off and without it being possible to restart it).
Remember to reseal the tank once the operation has been completed.
Make sure that the electric and hydraulic supply has been disconnected before carrying out any
maintenance intervention.
10. DISPOSAL
In the course of machine maintenance, or if the machine is scrapped, do not dispose of polluting parts into the
environment. Refer to local regulations with regard to their correct disposal. When scrapping the machine the
identification plate and any other documents must be destroyed.
23/ 31
11. INFORMATION ABOUT ORDERING
Standard equipment
Equipment Description Code
400 cm3/min grease pump 30 Kg (66lb) tank with inverter code 0083420 at
2477000
24 V DC
400 cm3/min grease pump 100 K g (220lb) tank with inverter code 0083420
2477001
at 24 V DC
400 cm3/min grease pump 80 Kg (176lb) transparent reservoir with inverter
2477100
code 0083420 at 24 V DC
Sumo Pump
2477050
400 cm3/min oil pump 30 Kg (66lb) tank inverter code 0083420 at 24 V DC
400 cm3/min oil pump 100 Kg (220lb) tank with inverter code 0083420 at 2477051
24 V DC
SUMO ATEX Pump in Stainless Steel 316 2477201
Sumo trolley Sumo Pump 30 K g sheet metal reservoir with inverter code 0083420 at
1525212
mounted 24 V DC
24V DC 0083420
Electromagn etic
110V AC 50/60Hz 0083421
inverter for base
230V AC 50/60HZ 0083422
Instrumentation and optional
Transparent Reservoir, including the tank (PN# 0295056) and all accessories required
0295210
reservoir for use( flanges, screws, nuts, seals)
24V DC 0083400
Dual Line
110V AC 50/60Hz 0083401
electric Inverter
230V AC 50/60HZ 0083402
24V DC 0083450
Pneumatic 24V AC 50/60Hz 0083451
inverter 110V AC 50/60Hz 0083452
230V AC 50/60HZ 0083453
Ultrasound level Ultrasound level with continuous reading 4..20 mA 0295140
Laser level Laser level with 2 digital outlets with 4 thresholds or 4..20 mA 0295130
Heater module Heater module for low temperatures < –5°C (23° F) 0295065
3
Reserve pumping module 200cm /min (24 cu. in) 0295040C
Pumping 3
Variable pumping module 100-200cm /min (12-24 cu. in) 0295060
element
Closure cap for fixed delivery pumping element 0295024
modules
Closure cap for variable delivery pumping element 0295035
Min/max oil level float kit 30 Kg (66lb) 0295150
Oil conversion Min/max oil level float kit 100 Kg (99.79kg) 0295160
Filling cap with filter 3130138
Terminal Box Bracket for installing a terminal wiring box onto the base pallet 3044455
bracket
Electrical control Bracket for installing a control box onto the base pallet 3044456
box Bracket
Metal Pallet used as the base of the pac kaging and also for installation of
Metal pallet 0043446
the pump.
24/ 31
SPARES
25/ 31
Pump body secondary unit code 0295000
Image 10
Image 11
Image 12
26/ 31
12. DIMENSIONS
To facilitate future maintenance, increase the spaces indicated by at least 200 mm (7.87 in.).
Image 13
Dimensions mm (i nches)
900 (35.43), 30 kg tank
A
1350 (53.14), 100 kg tank
B 615 (24.21), 30-100 kg tank
C 450 (17.71), 30-100 kg tank
D 148.5 (5.84), 30-100 kg tank
A metal pallet is used for transport and storage with packing at the side and a wooden cover.
The pump is fixed on a metal pallet, which allows safe handling using a transpallet or forklift truck. The metal pallet
has been designed so that it can be installed in the installation, being equipped with 4 (four) holes of Ø 14 mm
suitable for fixing to the floor.
The machine components can withstand temperatures, during storage, fr om -20 to + 50 °C (-4°F - 122°F); it is
therefore necessary, in order to avoid damages, for the machine to be started up w hen the machine has reached a
minimum temperature of +5 °C (+41°F).
It is necessary to carefully read the warnings and risks associated with using a lubricant pump. The operator must
understand how it works and must clearly understand the dangers by studying the user manual.
27/ 31
15. CONTRAINDICATIONS FOR USE
The check on compliance with the essential safety requirements and with the stipulations indicated in the machine
directives are to be carried out by means of compiling the checklists already made available and contained in the
technical file.
Three types of lists were used:
See below a list of dangers which have not been completely eliminated, but are considered acceptable:
· During assembly/maintenance it is possible that there may be an oil splash (consequently this operation must be
carried out using appropriate individual protective devices);
· contact with oil -> see instructions for using appropriate individual protective devices DPI;
· Use of an inappropriate lubricant -> fluid characteristics indicated both on the pump and in the manual (if in
doubt consult our Technical Office);
· protection against direct and indirect contact must be provided by the user;
· whenever the cover is opened for an intervention resealing the catch is essential;
· The pump’s working logic requires it to operate at all times, so it is necessary to pay attention to the electric
connection. If there is no current the customer’s machine can only be restarted following a reset while the
lubrication pump can restart automatically.
Unacceptabl e fluids
Fluids Dangers
Lubricant with abrasive additives High consumption of contaminated parts
Lubricant with silicon additives Jamming of the pump
Benzine – solvents – inflammable liquids Fire – explosion – damage to gaskets
Corrosive products Corrosion of the pump – injuries to persons
Water Pump oxidation
Food substances Contamination of these substances
28/ 31
16. GUARANTEE
All Dropsa products are guaranteed for a maximum of 12 months from the delivery date, for constructional and
material faults.
The guarantee is extended as indicated below:
Other components: 12 months from the date of installation; if installation takes place 6 months or more following the
delivery date, the guarantee will cover a maximum of 18 months from the delivery date.
In the event of equipment malfunction we must be notified of precise details of the fault encountered, supplying the
Dropsa code, the test number if present (expressed as: xxxxxx-xxxxxx), delivery and installation date and, finally,
conditions of using the product/s in question.
Once this information has been received we will decide at our own discretion whether to provide technical assistance
or to provide a return authorisation number (RAN) with precise instructions about returning the equipment.
After receiving the equipment and on the basis of careful analysis Dropsa reserves the right to decide whether to
repair or replace the product. If the guarantee is still valid we will proceed to repair or replace the part at our own
expense.
If the returned product is not faulty, Dropsa will decide at its own discretion whether or not to charge the customer for
the costs incurred (logistics etc.).
This guarantee must be understood to be cancelled if the product shows signs of damage and resulting from
incorrect use, negligence, normal wear and tear, chemical corrosion, installation not in compliance with the
instructions expressly indicated and use contrary to the manufacturer’s recommendations. Any changes, tampering
or alterations to the equipment or its parts made without written authorisation from Dropsa S.p.A., relieves the latter
from all liability and releases it from the obligations of the guarantee.
Parts subject to normal wear and tear and perishable parts are not covered by the guarantee.
Anything not expressly indicated must be considered to be excluded from the guarantee as well as damages or costs
resulting from faults in the actual product.
The conditions of validity of the Dropsa guarantee are unders tood to be implicitly accepted as soon as the equipment
is purchased. Any changes to or departures from this guarantee must only be considered valid after prior
authorisation from Dropsa S.p.A.
DROPSA S.p.A. declines any liability for personal injuries or damages to property in the event of failure to comply
with the instructions provided in this manual.
Any changes to the component parts of the system or a change in the intended use of the latter or its parts without
written authorisation from DROPSA S.p.A. relieve the latter from any liability for personal injuries and/or damage to
property and relieve it of any guarantee obligation.
29/ 31
17. DECLARATION OF CONFORMITY
Manufacturer:
DROPSA SpA
Company
Via B. Croce, 1 – 20090 Vimodrone (MI)
Address
02-250.791
Telephone
It is certified that:
The machine: Sumo Pump
* has been manufactured in accordance with the DIRECTIVES OF THE EUROPEAN COMMUNITY COUNCIL relating to:
machines (98/37/CE), low voltage (BT 73/23/CEE).
* has been manufactured, as applicable in accordance with the following standards and harmonised technical
specifications.
DROPSA SpA
Company
02/04/08
Signature
Date
30/ 31
18. DISTRIBUTORS
Dropsa China
Dropsa Lubrication Systems
(Shanghai) Co., Ltd
Tel: +86 (021) 67740275
Fax: +86 (021) 67740205
E-mail: [email protected]
31/ 31