Technical Data Sheet

Description
Description 90 A
Part Number 10115187
Marking according to EN A2
Conditions of use • organic gases and vapors with
a boiling point > 65° C

Colour code
brown

Labels

Characteristics
Weight [g] 210
Diameter [mm] 107
Height incl. thread [mm] 70
Connection EN 148 - 1

Breathing Resistance
at EN 14387 requirements Typical values
30 l / min 1,40 mbar 0,50 mbar
95 l / min 5,60 mbar 2,10 mbar

Concentration of Testing Gases


Class 1 1000 ppm [0,1 Vol.-%]
Class 2 5000 ppm [0,5 Vol.-%]

Performances
Filter type and class Gases of reference EN 14387 requirements Typical values
A2 cyclohexane [C6H12] 35 min 70 min

Material
Housing aluminium
Filtering material unimpregnated activated carbon

Details/Special Information
Storage conditions & time - 5 °C to + 50°C, < 90 % r. h. 6,0 years

Revision 6: August 2011


Technical Data Sheet

Description
Description 90 AB
Part Number 10098113
Marking according to EN A2, B2
Conditions of use • organic gases and vapors with a boiling point > 65° C
• inorganic gases and vapors, e.g. chlorine, hydrogen sulfide,
hydrogen cyanide

Colour code
brown
grey

Labels

Characteristics
Weight [g] 230
Diameter [mm] 107
Height incl. thread [mm] 70
Connection EN 148 - 1

Breathing Resistance
at EN 14387 requirements Typical values
30 l / min 1,40 mbar 0,65 mbar
95 l / min 5,60 mbar 2,95 mbar

Concentration of Testing Gases


Class 1 1000 ppm [0,1 Vol.-%]
Class 2 5000 ppm [0,5 Vol.-%]

Performances
Filter type and class Gases of reference EN 14387 requirements Typical values
A2 cyclohexane [C6H12] 35 min 65 min
B2 chlorine [Cl2] 20 min 45 min
hydrogen sulfide [H2S] 40 min 75 min
hydrocyanic acid [HCN] 25 min 50 min

Material
Housing aluminium
Filtering material impregnated activated carbon

Details/Special Information
Storage conditions & time - 5 °C to + 50°C, < 90 % r. h. 6,0 years

Revision 6: August 2011


Technical Data Sheet

Description
Description 90 E
Part Number 10115349
Marking according to EN E2
Conditions of use • sulfur dioxide, hydrogen chloride
and other acid gases

Colour code
yellow

labels

Characteristics
Weight [g] < 300 g
Diameter [mm] 107
Height incl. thread [mm] 70
Connection EN 148 - 1

Breathing Resistance
at EN 14387 requirements Typical values
30 l / min 1,40 mbar 0,55 mbar
95 l / min 5,60 mbar 2,50 mbar

Concentration of Testing Gases


Class 1 1000 ppm [0,1 Vol.-%]
Class 2 5000 ppm [0,5 Vol.-%]

Performances
Filter type and class Gases of reference EN 14387 requirements Typical values
E2 sulfur dioxide [SO2] 20 min 30 min

Material
Housing aluminium
Filtering material impregnated activated carbon

Details/Special Information
Storage conditions & time - 5 °C to + 50°C, < 90 % r. h. 6,5 years

Revision 6: August 2011


Technical Data Sheet

Description
Description 90 K
Part Number 10115320
Marking according to EN K2
Conditions of use • ammonia and organic ammonia derivatives

Colour code
green

labels

Characteristics
Weight [g] < 300 g
Diameter [mm] 107
Height incl. thread [mm] 70
Connection EN 148 - 1

Breathing Resistance
at EN 14387 requirements Typical values
30 l / min 1,40 mbar 0,45 mbar
95 l / min 5,60 mbar 2,05 mbar

Concentration of Testing Gases


Class 1 1000 ppm [0,1 Vol.-%]
Class 2 5000 ppm [0,5 Vol.-%]

Performances
Filter type and class Gases of reference EN 14387 requirements Typical values
K2 ammonia [NH3] 40 min 75 min

Material
Housing aluminium
Filtering material impregnated activated carbon

Details/Special Information
Storage conditions & time - 5 °C to + 50°C, < 90 % r. h. 6,5 years

Revision 6: August 2011


Technical Data Sheet

Description
Description 90 ABEK
Part Number 10098114
Marking according to EN A2, B2, E2, K1
Conditions of use • organic gases and vapors with a boiling point > 65° C
• inorganic gases and vapors, e.g. chlorine, hydrogen sulfide,
hydrogen cyanide
• sulfur dioxide, hydrogen chloride and other acid gases
• ammonia and organic ammonia derivatives

Colour code
brown
grey
yellow
green

label

Characteristics
Weight [g] 255
Diameter [mm] 107
Height incl. thread [mm] 70
Connection EN 148 - 1

Breathing Resistance
at EN 14387 requirements Typical values
30 l / min 1,40 mbar 1,0 mbar
95 l / min 5,60 mbar 4,20 mbar

Concentration of Testing Gases


Class 1 1000 ppm [0,1 Vol.-%]
Class 2 5000 ppm [0,5 Vol.-%]

Performances
Filter type and class Gases of reference EN 14387 requirements Typical values
A2 cyclohexane [C6H12] 35 min 55 min
B2 chlorine [Cl2] 20 min 45 min
hydrogen sulfide [H2S] 40 min 70 min
hydrocyanic acid [HCN] 25 min 45 min
E2 sulfur dioxide [SO2] 20 min 25 min
K1 ammonia [NH3] 50 min 90 min

Material
Housing aluminium
Filtering material impregnated activated carbon

Details/Special Information
Storage conditions & time - 5 °C to + 50°C, < 90 % r. h. 6,0 years

Revision 6: August 2011


Technical Data Sheet

Description
Description 90 ABEK 2
Part Number 10098112
Marking according to EN A2, B2, E2, K2
Conditions of use • organic gases and vapors with a boiling point > 65° C
• inorganic gases and vapors, e.g. chlorine, hydrogen sulfide,
hydrogen cyanide
• sulfur dioxide, hydrogen chloride and other acid gases
• ammonia and organic ammonia derivatives

Colour code
brown
grey
yellow
green

labels

Characteristics
Weight [g] 290
Diameter [mm] 107
Height incl. thread [mm] 75
Connection EN 148 - 1

Breathing Resistance
at EN 14387 requirements Typical values
30 l / min 1,40 mbar 1,20 mbar
95 l / min 5,60 mbar 4,80 mbar

Concentration of Testing Gases


Class 1 1000 ppm [0,1 Vol.-%]
Class 2 5000 ppm [0,5 Vol.-%]

Performances
Filter type and class Gases of reference EN 14387 requirements Typical values
A2 cyclohexane [C6H12] 35 min 60 min
B2 chlorine [Cl2] 20 min 60 min
hydrogen sulfide [H2S] 40 min 100 min
hydrocyanic acid [HCN] 25 min 65 min
E2 sulfur dioxide [SO2] 20 min 35 min
K2 ammonia [NH3] 40 min 50 min

Material
Housing aluminium
Filtering material impregnated activated carbon

Details/Special Information
Storage conditions & time - 5 °C to + 50°C, < 90 % r. h. 6,0 years

Revision 6: August 2011


Technical Data Sheet

Description
Description 90 AX
Part Number 10108408
Marking according to EN AX
Conditions of use • organic gases and vapors with a boiling point > 65° C
• low-boiling organic compounds [boiling point < 65° C]
of groups 1 and 2

Colour code
brown

labels

Characteristics
Weight [g] 230
Diameter [mm] 107
Height incl. thread [mm] 75
Connection EN 148 - 1

Breathing Resistance
at EN 14387 requirements Typical values
30 l / min 1,40 mbar 0,90 mbar
95 l / min 5,60 mbar 3,80 mbar

Concentration of Testing Gases


Class 1 1000 ppm [0,1 Vol.-%]
Class 2 5000 ppm [0,5 Vol.-%]

Performances
Filter type and class Gases of reference EN 14387 requirements Typical values
AX dimethyl ether [CH3OCH3] 50 min [at 0,05 Vol.-%] 75 min
isobutane [C4H10] 50 min [at 0,25 Vol.-%] 75 min

Material
Housing aluminium
Filtering material impregnated activated carbon

Details/Special Regulations
• Against the low boiling compounds of groups 1 and 2 gas filters AX according to EN 14387 must be used. The following maximum
concentrations and usetimes apply:

low boiling compounds group max. concentration [ml/m³] max. usetime [min]
100 40
1
500 20
1000 60
2
5000 20
• For low boiling compounds of group 3 protection is provided by filters other than AX [e.g. type B or K],
for low boiling compounds of group 4 gas filters provide no sufficient protection.

• AX filters may also be used as A2 filters. In this case however, they shall not be used against low boiling compounds.

• Use of AX filters against mixtures of low boiling compounds or mixtures of low boiling compounds and other organic compounds
is not permitted because desorption effects max occur.

• Only factory sealed AX filters must be used. Within one work shift [max. 8 hours] repeated use is permitted,
provided the maximum usetime, listed in the above table is not exceeded. Further use is not permitted.
storage condition&time 5°C to 50 °C < 90 % r.h.. 6,5 years