Fisher Optimized Antisurge Control Valves: High Reliability To Meet World-Class Production Demands

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Fisher Optimized Antisurge Control Valves

High reliability to meet world-class production demands


2 | Fisher ® Optimized Antisurge Valves

Fisher® The right choice for high reliability, fine control, fast stroking,
Optimized and easy tuning of your most critical application.
Antisurge
Control Valves

F
inally a robust, high-performance antisurge valve that can be easily

implemented and serviced in the field. A valve engineered from the

ground up to meet the specific needs of compressor antisurge applications

requiring the ultimate in control valve reliability.

Gone are the days of complicated actuation systems requiring factory-

authorized personnel to tune and commission. The Fisher® optimized antisurge

valve from Emerson makes short work of valve tuning, saving you money during

commissioning. It also pays back your original investment many times over

during the life of the equipment with superior dynamic performance.

We understand how to integrate antisurge control valve components—

the valve, actuator, FIELDVUE™ digital valve controller, and associated

instruments—into an effective design, thanks to more than 130 years of process

control experience. That’s why you’ll find the Fisher optimized antisurge valve

to be best-in-class for reliability, control, and commissioning.

Typical 3-Stage Antisurge


System Schematic
Antisurge System
High performance antisurge
1 2 3 valve actuation will help you
get the most from sophisticated
antisurge controllers.

ANTISURGE CONTROLLER
Fisher ® Optimized Antisurge Valves | 3

Site Testing >>


Certified Emerson technicians
worldwide can perform site testing
of your antisurge valve according to
the FGS 4L12 test.

Rigorous Factory Testing


Your compressor antisurge application is no place for uncertainty.
With the Fisher optimized antisurge valve and the Fisher FGS 4L11
test you have proof of performance. The FGS 4L11 test validates
the valve’s static performance, dynamic performance, and servo
robustness. Find out more from your Emerson sales contact.
4 | Fisher ® Optimized Antisurge Valves

High Reliability

Components within the Fisher optimized antisurge Dual certified as intrinsically safe and explosion proof,
valve were selected with high reliability in mind. the FIELDVUE digital valve controller also satisfies
the requirements of the European ATEX directive. Its
The FIELDVUE digital valve controller features a rugged enclosure meets NEMA 4X and IEC 60529 IP66 criteria.
I/P converter, a robust pneumatic relay, and potted
electronics to protect it from harsh plant environments. You can feel confident that FIELDVUE hardware
and software are proven. The FIELDVUE digital
valve controller is used in critical applications
in which reliability is paramount, such as safety
instrumented systems.

No Sliding Parts to Wear


Non-contact feedback technology in the
FIELDVUE digital valve controller eliminates
Cushioned Actuator the potentiometer and has no sliding parts
Mechanical air cushions within the
to wear. A magnet array and Hall Effect
high-speed actuator cylinder provide
sensor are used to detect valve position.
controlled deceleration to help protect
The heavy-duty mounting is designed for
actuator and valve components.
the harshest environments.
A check valve provides full speed
performance when the valve is moving
away from the travel stop.

Robust Instrument Mounting


Designed to withstand vibration
associated with compressor piping
systems, the FIELDVUE digital
valve controller mounting bracket
features an integral antirotator and
heavy duty gussets. All mounting
parts are stainless steel, easily
accessible, and facilitate remote
mounting of the instrument.
Fisher ® Optimized Antisurge Valves | 5

Ready For Any Climate


Elastomers within Fisher instruments
are designed to withstand temperatures
Arabian Petrochemical Company’s (Petrokemya, a as low as -40°C (-40°F) or as high as 93°C
SABIC affiliate) ethylene plant experienced capacity issues (200°F) while providing excellent resistance
with its main compressor antisurge valves—the most critical to common impurities within plant air.
A Case-In-Point valves in the facility.
Emerson engineers rely on decades of
non-metallic test experience to accurately
select elastomers for long-term reliability.
The existing valves were undersized for the valve outlet
velocity and took a long time to respond. Turbulence,
caused by the difference in gas velocity between the valve outlet and larger
downstream piping, contributed to unacceptable noise levels.

Emerson’s solution for the plant consisted of five fabricated valve types, each
incorporating proven WhisperFlo™ noise attenuation trim. Elevated pressure
drops and high flow rates inherent to antisurge applications warrant advanced
noise-control valve trims. WhisperFlo trim protects the compressor and piping
system from damaging vibration while providing superior noise reduction.
The trim was characterized to match capacity with the complex compressor
performance curve. The fabricated valve bodies provided flexibility in meeting
the existing face-to-face dimensions.

The valves were equipped with a fast-stroke, antisurge accessory package,


which reduced the overall cost of accessories while improving long-term
performance. FIELDVUE digital valve controllers provide performance
diagnostics and monitoring capabilities for these critical valves.

Partial Stroke Testing


and On-Seat Diagnostics
The FIELDVUE digital valve controller
Reduced Noise and Vibration automatically checks the condition of the valve
WhisperFlo is a multipath, multistage during each partial stroke test. Diagnostics such
valve trim capable of reducing noise as valve packing friction, air path leakage, valve
levels by as much as 40 dBA. Flow sticking, actuator spring rate, and bench set
patterns formed by laser cut discs help can be collected, viewed, and analyzed using
ensure repeatable noise attenuation and ValveLink™ software while the valve remains in
reduced pipe vibration. service, without impacting the process.
6 | Fisher ® Optimized Antisurge Valves

Peak Efficiency Lowers Operating Costs

By moving the compressor’s operating point


closer to the surge limit line, you can operate more
efficiently. This can mean significant reductions in
operating costs—as much as $250,000 USD annually
for a relatively small 4,500-horsepower compressor.
Larger compressors that are common to liquefied
natural gas facilities could see much larger savings.
Exclusively On Fisher Valves
The FIELDVUE digital valve offers an
The faster and more accurately an antisurge valve antisurge-specific tuning capability
moves, the more the savings. The Fisher optimized that is available exclusively on
antisurge valve is designed to deliver high- Fisher valves as part of the Fisher
performance actuation and improved control. Optimized Digital Valve.

The Fisher optimized antisurge valve achieves higher


gains, responds better, and has remarkable stability
thanks in part to minor loop feedback and other
proprietary techniques. Easily customized for critical
application requirements, these techniques marry
seamlessly with volume boosters to handle nearly
any actuator requirements.

Fast Stroke and


Controlled Deceleration
In one second, this Fisher optimized
antisurge valve reaches the capacity
required to protect the compressor.
It safely decelerates thanks to a
cushioned actuator.
Fisher ® Optimized Antisurge Valves | 7

A liquefied natural gas facility needed to replace all of its existing propane and
mixed refrigerant compressor antisurge valves. After seeing a demonstration
of the Fisher optimized antisurge valve, the plant turned to Emerson who has
proven its ability to understand and meet stringent valve performance criteria.
Fully Balanced Trim
The huge balance area of the unique
The 25 existing valves were replaced by NPS 12 through NPS 30 Fisher optimized
Fisher spoked plug helps the control
antisurge valves. valve resist pressure pulsations.

•The valves open in less than two seconds, as well as meet


stringent closed-loop control criteria.
•The measured linearity is less than 0.75%, and the
A Case-In-Point
valves have minimal overshoot in the open and closed
directions.
• It often requires about 12 hours to tune a non-Fisher antisurge
valve. With its fewer accessories and diagnostic capabilities,
tuning time for a Fisher optimized antisurge valve takes only minutes.

All this adds up to a more reliable antisurge valve solution for protecting
compressors and increasing process efficiency.

High Resolution
This Fisher optimized antisurge valve responds
to bidirectional step sizes of 0.25% thru 10% Negligible Overshoot
accurately and quickly. (Sample results from Overshoot is negligible for small and large
Fisher factory assurance testing on production steps. (Sample results from Fisher factory
equipment.) assurance testing on production equipment.)
8 | Fisher ® Optimized Antisurge Valves

Reduce Commissioning Time and Lower Costs

Factory expertise is not required to tune the Fisher


optimized antisurge valve. A technician may simply
use ValveLink software’s performance tuner or
the Stabilize/Optimize feature with real-time
graphics (shown far right). Configuration and tuning
can also be performed remotely by operators as
process requirements change.

Avoid the high cost of running separate power and


signal wiring by using the Fisher optimized antisurge
valve. Its FIELDVUE digital valve controller uses two-
wire 4 to 20 mA loop power.

Advanced, Local Tuning


Tune your Fisher optimized antisurge valve
using ValveLink Mobile software. You can
monitor the valve response and quickly adjust
gains to optimize performance. (Large step test
study shown in ValveLink Mobile software.)

Simple Setup
The setup wizard within ValveLink software
guides the technician through three simple
dialog screens for the Fisher optimized
antisurge valve. (Setup wizard shown in
ValveLink software.)
Fisher ® Optimized Antisurge Valves | 9

2625 Volume Booster


The Fisher 2625 volume booster
integrates seamlessly with the
FIELDVUE digital valve controller
and ValveLink software for robust,
high performance tuning.

Lead-Lag Remote Tuning with


Simple Setup Wizard
The lead-lag filter in the FIELDVUE digital valve
controller can be used to improve the response Stabilize/Optimize Feature
to small amplitude steps by overdriving the It is easy for anyone to get full control
set point. Asymmetric adjustments allow the of the Fisher optimized antisurge
response to be set independently in the opening valve without disturbing operations
and closing directions. Integrated, real-time using the Stabilize/Optimize feature.
graphics allow adjustments to be done remotely.
10 | Fisher ® Optimized Antisurge Valves

SS-263 Volume Booster

Today’s process plants require larger control valves The SS-263 volume booster carries on this tradition
than ever before. This increase in valve size has on a grand scale. With three times the capacity of the
stretched traditional volume boosters to their limit. 2625 volume booster, accessory mountings can be
The SS-263 volume booster brings the field-proven greatly simplified and the angle body style results in a
performance of the 2625 volume booster to a whole cleaner, more compact package.
new breed of large-scale control valves.
The rugged design features of the 2625 volume
The rock-solid reputation of the 2625 volume booster booster have been preserved while material selection
was designed specifically for use on control valves has been improved. The post-guided poppet valve
with the feature set and dynamic response required design eliminates problematic spool valves and
to integrate seamlessly with the FIELDVUE digital continues to work even in the presence of instrument
valve controller. air contaminants such as sand, rust, oil, and desiccants.

Modular trim components improve field maintenance


and optional high vibration mountings ready the SS-263
volume booster for the most severe applications.

Easy to Repair
Modular construction of the trim
allows for easy field maintenance of
all wear components.

High Vibration Applications


Booster body designed with integrated
high-vibration mounting options to handle
the most severe applications.

Desirable Failure Mode


Control valve continues to work in the event of
a booster diaphragm or spring failure.

Enhanced Throttling Control


High-performance trim package allows the
SS-263 to seamlessly integrate with the
FIELDVUE digital valve controller to maintain
precise throttling performance.
Fisher ® Optimized Antisurge Valves | 11

Noise Attenuation
Three-stage exhaust
trim greatly reduces
noise levels.

High Capacity
Delivers three times as
much air as a 2625 volume
booster to simplify accessory
mounting on large actuators.

Simplified Tubing
Manifold-style body
provides additional air
connections to simplify
Bubble Tight Shutoff and ruggedize the
Soft seat construction ensures instrument tubing for
the control valve maintains high vibration service.
its desired fail position upon
loss of plant air.

High Cycle Life


Low-stress springs
and rolling, convoluted
diaphragms provide the
durability to attain
1 million-plus cycles.
Whatever Your Needs, Wherever You Are

Worldwide service is of real value to every purchaser Contact your Emerson local business partner or sales
of a Fisher optimized antisurge valve. Emerson has office location for more information or to make
qualified, factory trained personnel in all parts of the a purchase. Their highly skilled and experienced
world ready to help with startup as well as service applications personnel are ready to help you take
advantage of the many benefits of the Fisher
and repair.
optimized antisurge valve. For more severe service
solutions, see us at www.FisherSevereService.com

Live Demonstration
We can demonstrate the Fisher
optimized antisurge valve at a
location near you. This means that
you can view the valve working in
real-time, talk to experts, and even
try it out for yourself.

On-site demonstrations are also


available at Emerson facilities in
Marshalltown, Iowa; Houston, Texas;
and Jubail, Saudia Arabia.

Arrange a demonstration with your


Emerson local business partner or
sales office today!

© Fisher Controls International LLC 2004, 2011 All Rights Reserved.

Fisher, FIELDVUE, WhisperFlo, ValveLink, and PlantWeb are marks owned by one of the companies in the
Emerson Process Management business division of Emerson Electric Co. Emerson Process Management,
Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are
the property of their respective owners.

The contents of this publication are presented for informational purposes only, and while every effort has
Emerson Process Management been made to ensure their accuracy they are not to be construed as warranties or guarantees, express
Marshalltown, Iowa 50158 USA or implied, regarding the products or services described herein or their use or applicability. All sales are
Sorocaba, 18087 Brazil governed by our terms and conditions, which are available upon request. We reserve the right to modify
Chatham, Kent ME4 4QZ UK or improve the designs or specifications of such products at any time without notice. Neither Emerson,
Dubai, United Arab Emirates Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection,
Singapore 128461 Singapore use, or maintenance of any product. Responsibility for proper selection, use, and maintenance of any
www.EmersonProcess.com/Fisher product remains solely with the purchaser and end user.

D351146X012 / MX46 (H:) / Oct11

You might also like