Fisher Optimized Antisurge Control Valves: High Reliability To Meet World-Class Production Demands
Fisher Optimized Antisurge Control Valves: High Reliability To Meet World-Class Production Demands
Fisher Optimized Antisurge Control Valves: High Reliability To Meet World-Class Production Demands
Fisher® The right choice for high reliability, fine control, fast stroking,
Optimized and easy tuning of your most critical application.
Antisurge
Control Valves
F
inally a robust, high-performance antisurge valve that can be easily
valve from Emerson makes short work of valve tuning, saving you money during
commissioning. It also pays back your original investment many times over
control experience. That’s why you’ll find the Fisher optimized antisurge valve
ANTISURGE CONTROLLER
Fisher ® Optimized Antisurge Valves | 3
High Reliability
Components within the Fisher optimized antisurge Dual certified as intrinsically safe and explosion proof,
valve were selected with high reliability in mind. the FIELDVUE digital valve controller also satisfies
the requirements of the European ATEX directive. Its
The FIELDVUE digital valve controller features a rugged enclosure meets NEMA 4X and IEC 60529 IP66 criteria.
I/P converter, a robust pneumatic relay, and potted
electronics to protect it from harsh plant environments. You can feel confident that FIELDVUE hardware
and software are proven. The FIELDVUE digital
valve controller is used in critical applications
in which reliability is paramount, such as safety
instrumented systems.
Emerson’s solution for the plant consisted of five fabricated valve types, each
incorporating proven WhisperFlo™ noise attenuation trim. Elevated pressure
drops and high flow rates inherent to antisurge applications warrant advanced
noise-control valve trims. WhisperFlo trim protects the compressor and piping
system from damaging vibration while providing superior noise reduction.
The trim was characterized to match capacity with the complex compressor
performance curve. The fabricated valve bodies provided flexibility in meeting
the existing face-to-face dimensions.
A liquefied natural gas facility needed to replace all of its existing propane and
mixed refrigerant compressor antisurge valves. After seeing a demonstration
of the Fisher optimized antisurge valve, the plant turned to Emerson who has
proven its ability to understand and meet stringent valve performance criteria.
Fully Balanced Trim
The huge balance area of the unique
The 25 existing valves were replaced by NPS 12 through NPS 30 Fisher optimized
Fisher spoked plug helps the control
antisurge valves. valve resist pressure pulsations.
All this adds up to a more reliable antisurge valve solution for protecting
compressors and increasing process efficiency.
High Resolution
This Fisher optimized antisurge valve responds
to bidirectional step sizes of 0.25% thru 10% Negligible Overshoot
accurately and quickly. (Sample results from Overshoot is negligible for small and large
Fisher factory assurance testing on production steps. (Sample results from Fisher factory
equipment.) assurance testing on production equipment.)
8 | Fisher ® Optimized Antisurge Valves
Simple Setup
The setup wizard within ValveLink software
guides the technician through three simple
dialog screens for the Fisher optimized
antisurge valve. (Setup wizard shown in
ValveLink software.)
Fisher ® Optimized Antisurge Valves | 9
Today’s process plants require larger control valves The SS-263 volume booster carries on this tradition
than ever before. This increase in valve size has on a grand scale. With three times the capacity of the
stretched traditional volume boosters to their limit. 2625 volume booster, accessory mountings can be
The SS-263 volume booster brings the field-proven greatly simplified and the angle body style results in a
performance of the 2625 volume booster to a whole cleaner, more compact package.
new breed of large-scale control valves.
The rugged design features of the 2625 volume
The rock-solid reputation of the 2625 volume booster booster have been preserved while material selection
was designed specifically for use on control valves has been improved. The post-guided poppet valve
with the feature set and dynamic response required design eliminates problematic spool valves and
to integrate seamlessly with the FIELDVUE digital continues to work even in the presence of instrument
valve controller. air contaminants such as sand, rust, oil, and desiccants.
Easy to Repair
Modular construction of the trim
allows for easy field maintenance of
all wear components.
Noise Attenuation
Three-stage exhaust
trim greatly reduces
noise levels.
High Capacity
Delivers three times as
much air as a 2625 volume
booster to simplify accessory
mounting on large actuators.
Simplified Tubing
Manifold-style body
provides additional air
connections to simplify
Bubble Tight Shutoff and ruggedize the
Soft seat construction ensures instrument tubing for
the control valve maintains high vibration service.
its desired fail position upon
loss of plant air.
Worldwide service is of real value to every purchaser Contact your Emerson local business partner or sales
of a Fisher optimized antisurge valve. Emerson has office location for more information or to make
qualified, factory trained personnel in all parts of the a purchase. Their highly skilled and experienced
world ready to help with startup as well as service applications personnel are ready to help you take
advantage of the many benefits of the Fisher
and repair.
optimized antisurge valve. For more severe service
solutions, see us at www.FisherSevereService.com
Live Demonstration
We can demonstrate the Fisher
optimized antisurge valve at a
location near you. This means that
you can view the valve working in
real-time, talk to experts, and even
try it out for yourself.
Fisher, FIELDVUE, WhisperFlo, ValveLink, and PlantWeb are marks owned by one of the companies in the
Emerson Process Management business division of Emerson Electric Co. Emerson Process Management,
Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are
the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has
Emerson Process Management been made to ensure their accuracy they are not to be construed as warranties or guarantees, express
Marshalltown, Iowa 50158 USA or implied, regarding the products or services described herein or their use or applicability. All sales are
Sorocaba, 18087 Brazil governed by our terms and conditions, which are available upon request. We reserve the right to modify
Chatham, Kent ME4 4QZ UK or improve the designs or specifications of such products at any time without notice. Neither Emerson,
Dubai, United Arab Emirates Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection,
Singapore 128461 Singapore use, or maintenance of any product. Responsibility for proper selection, use, and maintenance of any
www.EmersonProcess.com/Fisher product remains solely with the purchaser and end user.