4. Use of IS: 800, IS: 875 and Steel Tables is permitted, provided that they do not
contain anything other than the printed matter inside.
5. Consider fy = 250 N/mm2 and fu = 410 N/mm2 if not mention.
Q.1 (a) What are risk co-efficient, terrain factor and topography factor ? 03
(c) Compute the collapse load for the portal frame shown in Fig.1 and 07
design the members if factored Wu = 72 kN and fy of steel is 250 MPa.
(b) An ISMB 300@ 433.6 N/m beam has to be connected to the flange of 07
an ISHB 200@ 392.4 N/m column with 20 mm dia bolt. Design
unstiffened seated connection for a factored beam reaction of 120 kN.
Consider seat angle 150 x 75 x 12 mm and clearance between the
beam end and column = 3 mm.
OR
(b) A column ISHB 200@ 392.4 N/m has to support a beam ISHB 300@ 07
433.6 N/m. The beam transmits a factored end reaction of 100 kN.
Design an unstiffened welded seat connection. Consider seat angle
100 x 75 x 10 mm and clearance between the column flange and beam
= 5 mm.
OR
Q.3 (a) Explain stability against web buckling for plate girder. 07
(b) Enlist advantages and disadvantages of steel structures. 07
1
Q.4 Design a hand operated travelling crane simply supported by gantry 14
girder for the given data :
Span of gantry girder = 5m, Span of crane girder = 15 m, Crane
capacity = 200 kN, Self weight of crane girder excluding trolley = 200
kN, Self weight of trolley = 30 kN, Minimum hook approach = 1 m,
Distance between wheels = 3.5 m c/c, Self weight of rails = 0.3 kN/m.
Checks for buckling and deflections are not required.
OR
Q.4 Design members AB, AC and joint A of a truss, for the following data. 14
Consider member AC is horizontal and member AB is at an inclination
of 30° with member AC. Also sketch connection details with cross-
section of members.
Member Length Compressive Force Tensile force
AB 2.5 m 90 kN 60 kN
AC 2.8 m 75 kN 95 kN
Q.5 (a) Design a foot bridge for the particulars: (a) cross beams (b) most 14
heavily loaded bottom chord member (c) Vertical member in which
maximum compression occur. Type of girder = Lattice types, Span of
Girders = 16 m c/c, Cross girders spacing = 2 m c/c, Clear width
between main girders = 2.5 m, Pedestrian traffic = 4000 N/m2, Assume
Self weight of flooring = 480 N/m2, Self weight of cross beam =300 N,
Weight of one truss = 400 N/m,
E = 1 x 104 N /mm2.
OR
Q.5 (a) Define Shape Factor, Collapse load and Plastic Hinge. 03
(b) Derive the collapse load for fixed beam of length L, subjected to 04
concentrated load W at centre.
2W
2m 2m
B C
W
(2 Mp) D 40 kN 20 kN / m
5m B C
(Mp) A
(Mp) Mp 2Mp
2m 2m 6m
A Fig. 1 E Fig. 2
*************