Directional Seated Valves With Various Actuations: Basic Types and General Parameters

These directional seated valves use spring-loaded balls as valve elements to prevent leakage. They are manifold-mounted and available with various actuations, including solenoid, pressure, mechanical, and manual. Basic versions are 2/2-way and 3/2-way, while 3/3-way and 4/3-way functions are possible using two valves in one body. Valve banks with multiple parallel valves are also available. The valves can connect directly to pipe systems when equipped with connection blocks or sub-plates.

Uploaded by

pawa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
68 views2 pages

Directional Seated Valves With Various Actuations: Basic Types and General Parameters

These directional seated valves use spring-loaded balls as valve elements to prevent leakage. They are manifold-mounted and available with various actuations, including solenoid, pressure, mechanical, and manual. Basic versions are 2/2-way and 3/2-way, while 3/3-way and 4/3-way functions are possible using two valves in one body. Valve banks with multiple parallel valves are also available. The valves can connect directly to pipe systems when equipped with connection blocks or sub-plates.

Uploaded by

pawa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Seated valves

III-1.1
Directional seated valves with various actuations
These directional seated valves use spring loaded balls as valve elements Nomenclature: Directional seated valve,
and therefore do not show any leakage. They are manifold mounting and leakage free
are available with various actuations which always acts on an angled
lever pushing the valve element in the desired switching position. Design: Individual valve, manifold
The basic versions are designed as 2/2- and 3/2-way directional valves. mounting combination with
3/3- , 4/3-way functions are possible if two valves are housed in one valve connection blocks for pipe
body, whereas 4/2-way functions require an additional intermediate plate. connection
These valves may be directly installed in pipe systems, when equipped
with sub-plates enabling pipe connection. Many optional functions incor- Actuation: Solenoid
porated in these sub-plates i.e. pressure limiting valve or restrictor check Pressure actuated
valve widen the field of application for this • hydraulic
valve type. • pneumatic
Valve banks of these valves are also avail- Mechanical
able featuring several valves connected in • roller
parallel (see type VB). • pin
Manual
• hand lever
• adjusting knob

pmax: 320 ... 700 bar

Qmax: 6 ... 120 l/min

2 Type coding: GR 2 - 3
2 Actuation Size
Flow pattern

Basic types and general parameters


Size Flow Basic type (actuation) with oper. pressure pmax (bar) Tapped ports
Qmax (l/min) Solenoid pressure mechanically manually P, R, A, B 1)
actuated actuated actuated actuated
G WG H P K F F D

1) when combined
0 6 300 ... 500 500 – 350 ... 500 G 1/4 with sub-plate
1 12 350 ... 500 (700) 500 ... 700 400 ... 700 400 ... 700 G 1/4 and G 3/8 for pipe connec-
tion
2 25 350 ... 500 (700) 500 400 ... 500 400 ... 500 G 3/8 and G 1/2
3 65 350 ... 400 400 350 ... 400 – G 1/2 and G 3/4
4 120 350 – – – G 3/4 and G 1

Flow pattern
Coding 2/2-way 3/2-way 3/3-way 4/3-way 4/2-way directional
directional valve directional valve directional valve directional valve valve
flow pattern R2 S2 3 Z3 21 22 2) 4 3) Z4 3)
(actuation simplified symbols for 3/3-, 4/3- and 4/2-way functions
symbol to
be added)

2) not for size 4


3) only size 1

78 04/99
III-1.2 Seated valves

Actuations
solenoid pressure mechanical manual
hydraulical pneumatical roller pin hand lever turn knob
G WG H P K T F D

solenoid voltage: pressure pcontr max (bar) shifting force (N) shifting force (N) shifting torque (N)
12V DC, 24V DC (type G) 400 ... 700 15 25 ... 80 51 ... 20 25 ... 80 45 ... 98
230V AC 50/60 Hz (type WG) control pressure pcontr min (bar) shifting travel (mm) shifting travel (mm)
other voltage on request! 9 ... 16 2,5 ... 4 10,5 ... 30 4 and 5 20,5 ... 45

Additional versions
• Individual valve with orifice insert, check valve insert in port P and / or • 2/2- and 3/2-directional seated valves, size 1, with connection hole pat-
return pressure stop in port R tern conforming CETOP3 or ISO 4401, nom. size 6 4)
• Sub-plate with restrictor check valve or pressure limiting valve between • Directional seated valves with DC solenoid actuation in explosion proof
ports P and R design (Ex)s G4 4)
• Sub-plate with rectifying circuit by means of check valves ensuring in- • 4/3- and 3/3-way functions up to 700 bar, size 2 (type G 39-2, G49-2)
tended flow direction, suited for alternating direction of flow
4) see also “Additional information”
Order examples
PR 2-1 G 3-2-3/8-G24
Directional seated valve, pneumatically actuated, flow pattern R2, size 1 Directional seated valve, solenoid actuated, flow pattern 3,
size 2, sub-plate for pipe connection G 3/8, solenoid voltage 24V DC

Dimensions
Individual valve (see order example) Size H max 5) H1 max 5) B T max T1 m max
(kg) 6)
2/2- and 3/3- and
3/2-way 4/3-way
0 90,5 110,5 36 75 41,5 40 0,8/1,0
1 115 145 45 92 50 50 1,4/1,9
2 126,5 156,5 56 116 62,5 56 2,9/3,9
3 162 202 70 144 91,5 70 5,9/7,1
4 226 226 80 162 127 125 16,3/20,1

5) figures apply for solenoid actuation


6) individual valve with sub-plate

Valve with sub-plate (see order example)


Additional information
• Directional seated valves D 7300
• Valve banks type VB D 7302
• Plug with LED etc. D 7163
• Plug with economy circuit D 7813, D 7833
• Directional seated valves with standardized D 7300 N
connection hole pattern (CETOP3, NG6)
• Directional seated valves in explosion proof design D 7300 Ex
• see also section “Devices for special applications”
(Devices for explosion hazardous areas, Devices for up to 700 bar)
All dimensions in mm, subject
to change without notice!