Power Cables & Wires
Power Cables & Wires
Power Cables & Wires
( )
No. The name of equipment The name of manufactory Quantity
GJ250/12
4 1
GJ250/12 tubular stranding machine WuHu Electrician Equipment Company Limited
GJ500/1+6
5 3
GJ500/1+6 tubular stranding machine WuHu Electrician Equipment Company Limited
12+18/500
1
6 12+18/500 type stranding machine HeFei HuaXing Electrician Equipment Company Limited
12+18+24/500
7 1
12+18+24/500 type stranding machine HeFei HuaXing Electrician Equipment Company Limited
6+12+18+24/500
8 1
6+12+18+24/500 type stranding machine HeFei HuaXing Electrician Equipment Company Limited
9 6
bundle threading machine ShangHai NanYang Electrician Equipment Company Limited
10 4
mica tape wrapping machine ShangHai NanYang Electrician Equipment Company Limited
40
11 1
40 continuous vulcanizing runner extruder ZhengZhou Cable Group Electrician Equipment Company Limited
60
12 1
60continuous vulcanizing rubber extruder ZhengZhou Cable Group Electrician Equipment Company Limited
90+120
13 1
90+120 continuous vulcanizing runner extruder ZhengZhou Cable Group Electrician Equipment Company Limited
XK-550
14 1
XK-550 milling machine ZhengZhou Cable Group Electrician Equipment Company Limited
XK-400
15 1
XK-400 milling machine ZhengZhou Cable Group Electrician Equipment Company Limited
XJ-65
16 1
XJ-65 eight-roll film cooling doubling machine ZhengZhou Cable Group Electrician Equipment Company Limited
17
Rubber cutting machine ZhengZhou Cable Group Electrician Equipment Company Limited 1
X(S)N-55/30
18 1
X(S)N-55/30 press banbury mixer ZhengZhou Cable Group Electrician Equipment Company Limited
SJ45
19 6
SJ45 plastic extruder NanJing Arts And Crafts Equipment Company Limited
20 SJ65
SJ65 plastic extruder 3
NanJing Arts And Crafts Equipment Company Limited
SJ90
21 3
SJ90 plastic extruder NanJing Arts And Crafts Equipment Company Limited
22 SJ150
SJ150 plastic extruder 2
NanJing Arts And Crafts Equipment Company Limited
1+6/630
23 1
1+6/630 laying-up armoring machine WuHu Electrician Equipment Company Limited
P1.
ELECTRIC WIRES & CABLE
46+50/500 ( ) /
46+50/500 copper wire(copper tape) 2
ZheJiang PingHu Machinery Manufacturing Co., Ltd
screening/steel armoring machine
800 1
800 steel tape armoring machine ZheJiang PingHu Machinery Manufacturing Co., Ltd
9
wire coiler ShangHai NanYang Electrician Equipment Company Limited
3150 2
cable rewinding machine JiangSu SuYang Electrician Equipment Company Limited
1
high speed coiler ShangHai YaJie Electrician Equipment Company Limited
2
catenary cvline measuring instrument German Sikora Company
DGL-35/50
3 1
DGL-35/50 cable proof-voltage test equipment WuXi municipality YangShi detection instrument factory
DGL-15/30
4 DGL-15/30 cable proof-voltage test equipment WuXi municipality YangShi detection instrument factory 1
5 ZNY-12B
ZNY-12B proof-voltage test machine GuangZhou QingTian Industry Company Limited
QJ57
6 QJ57 D.C. resistance bridge ShangHai ZhengYang Instrument Factory 3
7 1
conductor resistance measuring device
QJ36
8 1
QJ36 D.C. twin-arm amphibious bridge ShangHai ammeter factory
QJ45
9 ShangHai Exact Science Instrument Company Limited 1
QJ45 portable line fault test instrument
ShangHai Ammeter D.V. Instrument Factory
P2.
continue the above table
( )
No. The name of equipment The name of manufactory Quantity
( )
QJ44
10 ShangHai LianYi Electrician Instrument(ShangHai Ammeter 1
QJ44 D.C. twin-arm bridge
Factory Limited Company)
ZC-90
11
ZC-90 insulation resistance measuring instrument ShangHai YuanZhong Electron Instrument Factory
CH-10-C
12 2
CH-10-C thickness measuring instrument ShangHai LiuLing Instrument Factory
TG328A
13 2
TG328A analytical balance ShangHai Balance Instrument Factory
JH21002
14 2
JH21002 electron exact balance ShangHai Balance Instrument Factory
CP-25
15 2
CP-25 impact slicing machine ShangHai SongJiang HuaLi Cable Accessory Factory
DQ-I
16 1
DQ-I resistance measuring clamp JiaXing XiuCheng District Experimental Instrument Factory
DQ-II
17 1
DQ-II bridge clamp ShangHai SongJiang HuaLi Cable Accessory Factory
ZC-36
18 2
ZC-36 high resistance instrument ShangHai Sixth Ammeter Factory
19 XG-E
NanTong HongDa Experimental Instrument Limited Company 1
XG-E insulation electrical performance testing box
JSL-500
20 1
JSL-500 electron tensile testing machine JiangDu JingYi Testing Machinery Limited Company
JSL-5000
21 1
JSL-5000 electron tensile testing machine JiangDu JingYi Testing Machine Limited Company
XL-50A
22 1
XL-50A tensile testing machine GuangZhou Testing Instrument Factory
LJ-500
23 1
LJ-500 tensile testing machine GuangZhou Testing Instrument Factory
LJ-5000A
24 1
LJ-5000A tensile testing machine GuangZhou Testing Instrument Factory
25 1
aging testing box ShangHai SongJiang HuaLi Cable Accessory Factory
27 1
heat-extension testing box JiaXing XiuCheng District Testing Instrument Factory
DDT-A
28 1
DDT-A Low multiple projection instrument WuXi Optical Instrument Factory
23JA
29 23JA outline measuring projection instrument ShangHai Optical Instrument Factory 1
30 X(S)K-160B ( )
1
X(S)K-160B twin-roll tubular-extracting plastic machine ShangHai XingZhi Machinery & Equipment Limited Company
/
31 electrically-heated /water-cooled flat vulcanizing machine ShangHai First Rubber Machine Factory 1
BC-1
32 1
BC-1 plastic low temperature brittleness testing instrument ShangHai Refrigerating Apparatus Limited Company
33 1
constant temperature water bath ShangHai SongJiang HuaLi Cable Accessory Factory
JC-1049B 1
34
JC-1049B digital display plasticity instrument JiangDu JingCheng Testing Instrument Factory
P3.
ELECTRIC WIRES & CABLE
35 LX-A
JiangDu JingCheng Testing Instrument Factory 1
Rubber hardness machine
36 1
twin-head rapid slicing machine JiangDu JingCheng Testing Instrument Factory
37 1
stirring machine ShangHai NanHui Instrument Factory
38 12
A.C. spark machine ShangHai WeiShi Industry Limited Company
P4.
Aluminium Stranded Conductors and Aluminium
Conductor Steel-Reinforced
Executive Standard
GB/T1179-1999 GB1179-83
It is manufactured according to the standard of GB/T1179-1999 and GB1179-83.
JL/G1AF
LGJF JL/G2AF Corrosion proof 10/2 500/65
aluminium conductor
JL/G3AF steel-reinforced
20
Normal ( ) Calculated Calculated Calculated Calculated Delivery ( ) Current
cross Conductor outer diameter breaking load area weight length Max.D.c Rating
sectional construction Resistance(20 ) 90
area (No./dia.)
2
mm mm mm N mm2 kg/km m /km A
16 7/1.70 5.10 2840 15.89 43.5 4000 1.802 111
25 7/2.15 6.45 4355 25.41 69.6 3000 1.127 147
35 7/2.50 7.50 5760 34.36 94.1 2000 0.8332 180
50 7/3.00 9.00 7930 49.48 135.5 1500 0.5786 227
70 7/3.60 10.80 10950 71.25 195.1 1250 0.4018 284
95 7/4.16 12.48 14450 95.14 260.5 1000 0.3009 338
120 19/2.85 14.25 19420 121.21 333.5 1500 0.2373 390
150 19/3.15 15.75 23310 148.07 407.4 1250 0.1943 454
185 19/3.50 17.50 28440 182.80 503.0 1000 0.1574 518
210 19/3.75 18.75 32260 209.85 577.4 1000 0.1371 575
240 19/4.00 20.00 36260 238.76 656.9 1000 0.1205 610
300 37/3.20 22.40 46850 297.57 820.4 1000 0.09689 707
400 37/3.70 25.90 61150 397.83 1097 1000 0.07247 851
500 37/4.16 29.12 76370 502.90 1387 1000 0.05733 982
630 61/3.63 32.67 91940 631.30 1744 800 0.04577 1140
800 61/4.10 36.90 115900 805.36 2225 800 0.03588 1340
P5.
ELECTRIC WIRES & CABLE
20
/ ( / ) Calculated Calculated Calculated Calculated Delivery ( ) Current
Conductor outer diameter breaking load area weight length Max.D.c Rating
Normal construction Resistance(20 ) 90
cross (No./dia.)
sectional
area Al St Al St
mm2 mm mm N mm2 kg/km m /km A
10/2 6/1.50 1/1.50 4.50 4120 10.60 1.77 43.1 3000 2.706 87
16/3 6/1.85 1/1.85 5.55 6130 16.13 2.69 65.6 3000 1.779 111
25/4 6/2.32 1/2.32 6.96 9290 25.36 4.23 103.2 3000 1.131 147
35/6 6/2.27 1/2.72 8.16 12630 34.86 5.81 141.8 3000 0.8230 180
50/8 6/3.20 1/3.20 9.60 16870 48.25 8.04 196.3 2000 0.5946 227
50/30 12/2.32 7/2.32 11.60 42620 50.73 29.59 374.7 3000 0.5692 227
70/10 6/3.8 1/3.80 11.40 23390 68.05 11.34 276.8 2000 0.4217 287
70/40 12/2.72 7/2.72 13.60 58300 69.73 40.67 515.0 2000 0.4141 287
95/15 26/2.15 7/1.67 13.61 35000 94.39 15.33 382.6 2000 0.3058 338
95/20 7.4.16 7/1.85 13.87 37200 95.14 18.82 412.3 2000 0.319 338
95/55 12/3.20 7/3.20 16.00 78110 96.51 56.30 712.8 2000 0.2992 338
120/7 18/2.90 1/2.90 14.50 27570 118.89 6.61 380.6 2000 0.2422 390
120/20 26/2.38 7/1.85 15.07 41000 115.67 18.82 469.1 2000 0.2496 390
120/25 7/4.72 7/2.10 15.74 47880 122.48 24.25 530.9 2000 0.2345 390
120/70 12/3.20 7/3.60 18.00 98370 122.15 71.25 902.1 2000 0.2364 390
150/8 18/3.20 1/3.20 16.00 32860 144.76 8.04 463.4 2000 0.1989 454
150/20 24/2.78 7/1.85 16.67 46630 144.67 18.82 552.1 2000 0.1980 454
150/25 26/2.70 7/2.10 17.10 54110 148.86 24.25 603.9 2000 0.1930 454
150/35 30/2.50 7/2.50 17.50 65020 147.26 34.36 679.6 2000 0.1962 454
185/10 18/3.60 1/3.60 18.00 40880 183.22 10.18 586.5 2000 0.1572 518
185/25 24/3.15 7/2.10 18.90 59420 187.04 24.25 709.6 2000 0.1542 518
185/30 26/2.98 7/2.32 18.88 64320 181.34 29.59 736.1 2000 0.1592 518
185/45 30/2.80 7/2.80 19.60 80190 184.73 43.10 852.5 2000 0.1564 518
210/10 18/3.80 1/3.80 19.00 45140 204.14 11.34 653.4 2000 0.1411 575
210/25 24/3.33 7/2.22 19.98 65990 209.02 27.10 793.0 2000 0.1380 575
210/35 26/3.22 7/2.50 20.38 74250 211.73 34.36 858.0 2000 0.1363 575
210/50 30/2.98 7/2.98 20.86 9.830 209.24 48.82 965.6 2000 0.1381 575
240/30 24/3.60 7/2.40 21.60 75620 244.29 31.67 926.8 2000 0.1181 610
240/40 26/3.42 7/2.66 21.66 83370 238.85 38.90 969.0 2000 0.1209 610
240/55 30/3.20 7/3.20 22.40 102100 241.27 56.30 1113.4 2000 0.1198 610
300/15 42/300 7/1.67 23.01 68060 296.88 15.33 943.0 2000 0.09742 707
300/20 45/2.93 7/1.95 23.43 75680 303.42 20.91 1005.2 2000 0.09520 707
300/25 48/2.85 7/2.22 23.76 83410 306.21 27.10 1062.0 2000 0.09433 707
300/40 24/3.99 7/2.66 23.94 92220 300.09 38.90 1138.5 2000 0.09614 707
300/50 26/3.83 7/2.98 24.26 103400 299.54 48.82 1215.5 2000 0.09636 707
300/70 30/3.60 7/3.60 25.20 128000 305.36 71.25 1409.2 2000 0.09463 707
P6.
Aluminium conductor steel-reinforced
20
/ ( / ) Calculated Calculated Calculated Calculated Delivery ( ) Current
Conductor outer diameter breaking load area weight length Max.D.c Rating
Normal construction Resistance(20 ) 90
cross (No./dia.)
sectional
area Al At Al At
mm2 mm mm N mm2 kg/km m /km A
400/20 42/3.15 7/1.96 26.91 88850 406.40 20.91 1290.2 1500 0.07104 851
400/25 45/3.33 7/2.22 26.64 95940 391.91 27.10 1299.1 1500 0.07370 851
400/35 48/3.22 7/2.50 26.82 103900 390.88 34.36 1353.8 1500 0.07389 851
400/50 54/3.207 7/3.07 27.63 123400 399.73 51.82 1516.5 1500 0.07232 851
400/65 26/4.42 7/3.44 28.00 135200 398.94 65.06 1619.1 1500 0.07236 851
400/95 30/4.16 19/2.50 29.14 171300 407.75 92.27 1866.8 1500 0.07087 851
500/35 45/3.75 7/2.50 30.00 119500 497.01 34.36 1647.5 1500 0.05812 982
500/45 48/3.60 7/2.80 30.00 128100 488.58 43.10 1693.4 1500 0.05912 982
500/65 54/3.44 7/3.44 30.96 154000 501.88 65.06 1904.0 1500 0.05760 982
Power Cables
1 Brief Introduction
1.1 Introduction to product
Generally, cable model selection means to choose the appropriate cable and model.
Cable model specifies the cable structure of conductor, insulation, shield, sheath etc. And rated
voltage; however, the specification of cable indicates the core and section area of conductor.
To ensure the cable supplied by us can operate reliably for a long time in transmission line, please
read the following items fully and carefully before selection the appropriate model and specifications.
1
Table 1 The relationship between cable and power system
Cable Adequate power system
IC Allowable
Rated cable capacitive current IC
Type voltage U0/U(kV) Category Grounding system Normal system voltage Power circuit
35kV 10kV 6kV
A ( 110kV
) Direct grounding 110kV above
1.8/3, 3.6/6, 6/10 A type (Effective
1
8.7/15, 12/20, 21/35 grounding Double circuit
system of 35kV
Small resistance 35kVbelow
neutral point)
grounding
P7.
ELECTRIC WIRES & CABLE
Cable specification is the size of conductor section. It determines the current rating under
the same operation condition. The manual gives the current rating of cross-link cable for each
kinds of specification under special operation condition. The current rating shall be conversed
into the one under real operation condition by customer when choosing cable specification.
Forthermore, the customer shall take the size of emergency over load and continuous time.
1.4
Choosing the size of conductor section shall meet the requirements of short circuit in trouble
when system is in short circuit, otherwise, the phenomeny of cable conductor will burn. The
size of short circuit has close relationship with the time of short circuit.
1.5
Operation cost is considered selection economic current density
( )
S I m/J 0 (I m A J0 A/mm 2)
Cable conductor itself is a resistance, which will consume power to generate heat, i.e. line loss.
The bigger the cable specification is, the smaller line loss and the operation cost is; however, the
higher the cable price, the bigger the line investment. It is complex for considering the density
calculation formula of economic current after taking the factors into consideration. We are here
just to remind the customer. Generally, the requirement is S=Im/J0 (Im is Max. working current A
2
J0 is economic current density A/mm ).
( )
Normal MV cross-link cable of our company (U0 is 21kV and 26kV, section is 500mm2 and above
is not concluded) all adopt bronze shield, the shield section S= No. of layer width thickness,
U0 is 21kV and 26kV, the metal shield of cable of section is 500mm2 and above should take the
structure of copper wires shield. Copper tape shield cable is generally used in non-effective
grounding system of small short circuit current.
If the short circuit current of your power system is larger (take resistance grounding system for
example),the shield section is required larger, then you must note that the required shield area of
shield.
1.7 U=I R I
R U (
5%U 2.5%U 4%U )
Power system has specifications on line voltage, certain voltage drop will occur when current passes
cable line U=I R where I is line working voltage; R is AC resistance of cable for line length. U
shall be lower the Max. voltage drop made by system ( if HV & LV motor circuit is 5%U, working lighting
line is 2.5%U inside room, outside working lighting line is 4%U et, HV circuit can not be considered).
P8.
2 Brief Introduction of Product
2.1 Introduction to product
1~35kV
GB/T12706-2008 IEC60502-2004
A B
C A
GB/T19666-2005 A
GB/T19666-2005
GB/T19666-2005
Power cable is widely used in the departments of electricity, construction, industrial & mining, metallurgy,
petrochemicals and communication in transmission and distribution. It is an important part in power
system, which conveys and distributes high power current. The features of 1 35kV plastic insulating
power cable, made by our company, meet totally with the standards of GB/T12706-2008 and IEC60502-2004.
Derives from flame-retardant, low smoke no-halogen flame-retardant,
fire-resistant, hardy and waterproof type, forms series and specialization, among which flame-retar
dant type has A, B and C levels. A type flame-retardant cable adopts new structure, not only electric
feature totally agree with the requirements of national standards, but also bundle burning test reaches
the requirement of A type GB/T19666-2005 The requirement of Bundle flame-retardant Features
Fire-resistant type power cable is reliable in whole features, the features of fire-resistant agree with
The Requirement of Fire-resistant Features GB/T19666-2005. The features of low smoke
& no-halogen, low smoke & low halogen flame-retardant type flame-retardant power cable meets
with The Requirement of No-halogen Features and The Requirement of Low Smoke Features .
2.2 35kV
35kV and below Cross-linked Polyethylene Insulated Power Cable
Executive standards:
GB/T12706-2008 1kV(Um=1.2 kV) 35kV(Um=40.5 kV)
The product is designed and made by GB/T12706-2008 Cables with Extruded Insulation
and their accessories for Ratd Voltage 1kV(Um=1.2 kV)to 35kV(Um=40.5 kV) .
YJV YJLV
Cu or Al Conductor XLPE Insulated PVC Sheathed Power Cable
YJV22 YJLV22
Cu or Al Conductor XLPE Insulated PVC Sheathed St.Tape Armor Power Cable
YJV23 YJLV23
Cu or Al Conductor XLPE Insulated PE Sheathed St.Tape Armor Power Cable
YJV32 YJLV32
Cu or Al Conductor XLPE Insulated PVC Sheathed thin st. Wire Armor Power Cable
YJV42 YJLV42
Cu or Al Conductor XLPE Insulated PVC Sheathed thick st. Wire Armor Power Cable
YJV33 YJLV33
Cu or Al XLPE Insulated PVC Sheathed thin st. Wire Armor Power Cable
YJV43 YJLV43
Cu or Al Core XLPE Insulated PVC Sheathed Thick st. Wire Armor Power Cable
N-YJV
Cu Conductor XLPE Insulated PVC Sheathed Fire-resistant Power Cable
P9.
ELECTRIC WIRES & CABLE
Model Name
N-YJV22 Cu Conductor XLPE Insulated PVC Sheathed St.Tape Armor Fire-resistant Power Cable
N-YJV23
Cu XLPE Insulated PE Sheathed St.Tape Armor Fire-resistant Power Cable
Z-YJV Z-YJLV
Cu or Al XLPE Insulated PVC Sheathed flame-retardant Power Cable
Z-YJV22 Z-YJLV22
Cu or Al XLPE Insulated PVC Sheathed st.Tape Armor flame-retardant Power Cable
Z-YJV32 Z-YJLV32
Cu or Al XLPE Insulated PVC Sheathed Thin st. Wire flame-retardant Power Cable
Z-YJV42 Z-YJLV42
Cu or Al XLPE Insulated PVC Sheathed Thick st. Wire flame-retardant Power Cable
DDZ-YJV DDZ-YJLV
Cu or Al XLPE Insulated PVC Sheathed Low Smoke & Halogen flame-retardant Power Cable
DDZ-YJV22 DDZ-YJLV22
Cu or Al XLPE Insulated PVC Sheathed st.Tape Armor Low Smoke & Halogen flame-retardant Power Cable
DDZ-YJV32 DDZ-YJLV32 Cu or Al XLPE Insulated PVC Sheathed thin st. Wire Armor Low Smoke & Halogen flame-retardant Power Cable
DDZ-YJV42 DDZ-YJLV42
Cu or Al XLPE Insulated PVC Sheathed Thick Wire Armor Low Smoke & Halogen flame-retardant Power Cable
WDZ-YJY WDZ-YJLY
Cu or Al XLPE Insulated Polyolefin Sheathed Low Smoke No-halogen flame-retardant Power Cable
WDZ-YJY23 WDZ-YJLY23 Cu or Al XLPE Insulated Polyolefin Sheathed St.Tape Armor Low Smoke No-halogen flame-retardant Power Cable
WDZ-YJY33 WDZ-YJLY33
Cu or Al XLPE Insulated Polyolefin Sheathed Thin Wire Armor Low Smoke No-halogen flame-retardant Power Cable
WDZ-YJY43 WDZ-YJLY43 Cu or Al XLPE Insulated Polyolefin Sheathed Thick st. Wire Armor Low Smoke No-halogen flame-retardant Power Cable
Model Explanation
2
Conductor section mm
Core No.
Rated voltage U0/U
Over sheath
Armor
Sheath
Conductor
Insulation
( ) Flame-retardant (fire-resistant)
P10.
continue the above table
Items Code Notes
2 St. tape armor
Armor 3 Thin St. wire armor
4 Thick St. wire armor
2 PVC
Outer covering
3 PE
2.2.2.2 90 ( 5S)
250
Max. temperature of conductor is 90 in normal operation, Max. temperature of cable conductor
does not overpass 250 in short circuit (Max. continuous time is not over 5s).
2.2.2.3 GB/T3956-1997
Dc resistance of conductor is in line with the specification of GB/T3956-1997.
2.2.2.4 0 4
Surrounding temperature is not below than 0 , Min. bending radius refers to table 4.
Min. Bending radius of close with connection 15D 12D 12D 10D
box and terminal cable
D Notes: D Outer diameter of cable
P11.
ELECTRIC WIRES & CABLE
2 2
1
1 4
5
3 3
1 1 1
2 2 2
10
10 4 10
5 4
3
3 5
3
3 10
1 1
4
2 2
2 4
5 5
1
3
3
Type YJV, YJLV Type YJV22, YJLV22 Type YJV32, YJLV32, YJV42
Cable section Cable section YJLV42 cable section
4
1 1
10
2 2 1
10
10 4 2
5 5
3 3 3
2
2
1 1
1
5 5
2
4 4
3 3 3
3
5
2
1 2
1 1
10 2 10
10 4
4 5
3
3 3
3 3
1 2 1
2 1
2
3 5 10
4
4 5
10
Type YJV, YJLV Type YJV22, YJLV22 Type YJV32, YJLV32, YJV42
Cable section Cable section YJLV42 cable section
P12.
3 3
2 5
2
1 1
10 2
3
4 1
5 3
4
3 3
4
1
1 1
2
2
2
4 10
3
10 10 5
2
2
3
2 2 2
1 1 1
10 10
10 4 4
5 5
3 3
Type YJV, YJLV Type YJV22, YJLV22 Type YJV32, YJLV32, YJV42
Cable section Cable section YJLV42 cable section
2 4 3
4
1 1 2
2 1
3
5 10
10
10
5
3
3
10 4
1
1
2 2 2
4
3 5
10 10
1
5
3
YJV YJLV YJV22 YJLV22 YJV32 YJLV32 YJV42 YJLV42
Type YJV, YJLV Type YJV22, YJLV22 Type YJV32, YJLV32, YJV42
Cable section Cable section YJLV42 cable section
1 1 1
2 2 2
9 9
9
4 4
5 3 5
3 3
Type VV32 VLV32 YJV32 YJLV32 Type VV VLV YJV YJLV Type VV22 VLV22 YJV22 YJLV22
VV42 VLV42 YJV42 YJLV42 Cable section cable section
Cable section
P13.
ELECTRIC WIRES & CABLE
3
5
9
7
2
1
6 1
2 6
7
8 4
3
3
5
9
7
1 2
6 1
2 6
7
8 4
3
5 3
3 4
2 6
7 6
1 1
8
8 8
6 10
2 7
1
7 2
10 5
3
Type YJV, YJLV Type YJV22, YJLV22 Type YJV32, YJLV32, YJV42
Cable section Cable section YJLV42 cable section
P14.
4 hours AC voltage testing for cable insulation core (sampling test)
Dip the insulation core removed outer covering for 1 hour, then apply power frequency voltage in
Table 10 between conductor and water, holding on for 4 hours, the insulation don't break.
10 4 Table 10 AC voltage test for 4 hours
Rated voltage U 0(kV) 0.6 1.8 3.6 6 8.7 21 36
U Testing voltage U(kV) 2.4 7.2 14.4 24 34.8 84 104
Time added in testing(min.) 4 4 4 4 4 4 4
The reference outer diameter and weight of common used cable type, such as YJV, YJLV, YJV22,
YJLV22 and YJV32, YJLV32 are listed in table 11 32. All data are not technical parameter checked
by standard, and not checked as contents.
11 0.6/1 kV Table 11 0.6/1 kV single core
Outer diameter mm Weight kg/km
Core No.
section area
2 YJV,YJLV YJV22,YJLV22 YJV32,YJLV32 YJV YJLV YJV22 YJLV22 YJV32 YJLV32
mm
1 1.5 6.0 45 36
1 2.5 6.5 57 42
1 4 7.0 76 51
1 6 7.7 107 73
1 10 9.0 13.0 14.6 156 95 282 221 381 298
1 16 10.0 14.0 15.7 218 122 354 258 478 348
1 25 11.3 15.3 17.1 315 163 466 314 629 424
1 35 12.4 16.4 18.4 411 200 576 365 778 493
1 50 14.1 18.1 20.3 541 254 723 437 976 590
1 70 15.9 19.9 22.3 746 333 951 537 1284 725
1 95 17.4 21.4 24.0 993 419 1217 642 1643 867
1 120 19.4 23.2 26.0 1238 517 1473 753 1989 1017
1 150 21.6 25.2 28.2 1524 633 1772 881 2392 1189
1 185 23.6 27.2 30.5 1880 768 2151 1038 2904 1401
1 240 26.2 29.8 33.4 2434 970 2731 1268 3687 1712
1 300 28.8 32.2 36.1 3017 1183 3327 1493 4491 2016
1 400 32.6 36.2 40.5 3834 1494 4198 1858 5667 2508
1 500 36.2 41.0 45.9 4868 1875 5651 2658 7629 3588
P17.
ELECTRIC WIRES & CABLE
P18.
16 0.6/1 kV 3+1 Table 16 0.6/1 kV 3+1 cores
Outer diameter mm Weight kg/km
Core No.
section area
mm
2 YJV,YJLV YJV22,YJLV22 YJV32,YJLV32 YJV YJLV YJV22 YJLV22 YJV32 YJLV32
P19.
ELECTRIC WIRES & CABLE
P20.
23 8.7/10 (15)kV 1 Table 23 8.7/10 (15)kV 1 core
Outer diameter mm Weight kg/km
Core No.
section area YJV,YJLV YJV22,YJLV22 YJV32,YJLV32
2 YJV YJLV YJV22 YJLV22 YJV32 YJLV32
mm
1 25 22.8 26.0 29.1 694 542 985 830 1330 1121
1 35 23.9 27.5 30.8 813 601 1152 935 1555 1262
1 50 25.5 28.5 31.9 975 688 1377 1067 1859 1440
1 70 27.1 30.0 33.6 1208 795 1720 1286 2322 1736
1 95 28.6 32.0 35.8 1486 911 2018 1429 2724 1929
1 120 30.4 33.0 37.0 1760 1039 2310 1566 3119 2114
1 150 32.0 35.0 39.2 2052 1162 2669 1739 3603 2348
1 185 33.6 37.0 41.4 2424 1312 3065 1918 4138 2589
1 240 36.2 39.0 43.7 3028 1565 3917 2429 5288 3279
1 300 38.4 41.5 46.5 3627 1793 4542 2682 6132 3621
P21.
ELECTRIC WIRES & CABLE
P22.
31 26/35kV 1 Table 31 26/35kV 1 core
Outer diameter mm Weight kg/km
Core No.
section area YJV,YJLV YJV22,YJLV22 YJV32,YJLV32
2 YJV YJLV YJV22 YJLV22 YJV32 YJLV32
mm
1 50 39.1 42.1 47.2 1684 1394 2591 2301 3498 3106
1 70 40.7 43.8 49.1 1974 1558 2904 2487 3920 3357
1 95 42.4 45.6 51.1 2287 1710 3276 2699 4423 3644
1 120 44.0 47.2 52.9 2593 1868 3618 2893 4884 3906
1 150 45.8 49.0 54.9 2929 2030 4016 3117 5422 4208
1 185 47.6 50.8 56.9 3354 2232 4484 3362 6053 4539
1 240 49.8 53.0 59.4 4018 2530 5179 3691 6992 4983
1 300 52.2 55.6 62.3 4679 2813 5945 4079 8026 5507
1 400 55.6 59.0 66.1 5741 3273 7090 4622 9572 6240
1 500 59.4 65.0 72.8 7111 4101 8632 5622 11653 7590
2.2.10
Continuous load current rating and short circuit current of XLPE insulated power cable
2.2.10.1 IEC-287(1982-1991)
( 100%)
33 36
Reference benchmark of current rating is supplied according to IEC-287 (1982-1991) for XLPE insulated
power cable under special condition of continuous load (load factor 100%) in this manual. The current
rating of cable under real operation condition must be corrected as factors in table 33 36.
33
Table 33 Correct factors of current rating under different air temperature
Air temperature
Working temp.
of conductor 10 15 20 25 30 35 40 45 50
34
Table 34 Correct factors of current rating under different soil temperature
Soil temperature
Working temp.
of conductor 10 15 20 25 30 35
P23.
ELECTRIC WIRES & CABLE
35
Table 35 Correct factors of current rating under different soil thermal factor
Section Soil thermal factor k.m/W
2
Voltage(kV) area(mm ) 0.8 1.0 1.2 1.5 2.0
35 1.06 1.00 0.95 0.88 0.80
0.6/1~6/6 50~150 1.08 1.00 0.94 0.87 0.77
185 1.09 1.00 0.93 0.85 0.76
35 1.05 1.00 0.95 0.89 0.80
6/10~8.7/15 50~150 1.06 1.00 0.94 0.88 0.79
185 1.07 1.00 0.93 0.86 0.77
95 1.05 1.00 0.95 0.90 0.82
12/20~26/35
120 1.06 1.20 0.94 0.83 0.80
w
Note: the table is used only for the correction of current rating, under the column of soil thermal
factor where water change has not happened.
36 ( )
Table 36 Correct factors of current rating for cable (wire) parallel laying
e
cable arrangement Dc ( value) correct factor
e
D c
<0.5 0.89
multiple cores cable
<0.75 0.84
e
<1.0 0.93
single core cable
<1.5 0.92
<1.9~1.5 0.99
<1.4~1.0 0.97
<0.5 0.90
multiple cores cable 4~3 0.99
2.9~2.0 0.97
1.9~1.0 0.94
<0.5 0.85
3.9~3.0 0.99
2.9~2.0 0.98
multiple cores cable group
1.9~1.0 0.96
<0.5 0.88
e
<0.5 0.93
multiple cores laying by wall
Notes: Single core group takes the current rating quantity of tri-angle arrangement as benchmark in the table.
2.2.10.2
Continuous load current rating quantity of cable
Notes:
1. YJV22 YJLV22 YJV32 YJLV32 YJV23 YJLV23 YJV33 YJLV33
3 10A
Continuous load current rating quantity of armor cable YJV22, YJLV22, YJV32, YJLV32, YJV23,
YJLV23, YJV33, YJLV33 is smaller 3 10A than that without armor with the same specifications,
the manual does not give the current rating quantity of armor cable, the customer can make
calculation by this.
2. 2
In the following table, flat arrangement of single core cable and the distance between central axis
of neighboring cable equals 2 times than outer diameter of cable.
P24.
37 0.6/1kV 1.8/3kV (A)
Table 37 Allowable continuous current rating quantity of 0.6/1kV 1.8/3kV for XLPE insulated power cable
Model YJV,YJLV,YJY,YJLY YJV,YJLV,YJY,YJLY
Core No. 2,3,3+1,3+2,4+1,5 cores Single sore
Laying In air In soil
In air In soil
Arrangement of single core cable
Material of core Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
1.5 20 / 31 / 26 / 32 / 33 / 35 /
2.5 27 21 41 32 34 26 42 33 43 32 46 36
4 35 28 53 42 44 35 56 44 56 42 59 47
6 45 36 66 54 56 45 70 57 70 54 74 60
10 63 49 90 69 77 59 97 75 94 69 99 76
16 84 65 117 91 100 78 125 99 120 90 128 99
25 113 88 151 117 130 100 165 125 155 115 164 128
35 139 108 181 140 160 125 200 155 185 135 197 153
50 161 125 210 163 195 150 245 190 220 165 232 180
Norm.section 70 204 158 257 200 245 190 305 240 270 200 285 221
mm2
95 252 195 310 240 300 230 375 290 320 240 342 265
120 291 226 351 273 349 270 435 340 365 275 388 301
150 333 258 393 305 400 310 500 390 410 310 436 338
185 385 299 445 346 465 360 580 450 465 355 496 385
240 457 356 516 402 550 430 685 535 540 410 577 449
300 527 410 583 454 635 495 795 615 610 465 654 508
400 600 475 645 510 745 590 930 730 695 535 749 585
500 860 685 1080 850 780 610 858 673
630 990 800 1250 1000 880 695 981 774
Surrounding temp.( ) 40 25 40 25
Surrounding temp.( ) 40 25 40 25
P25.
ELECTRIC WIRES & CABLE
Surrounding temp.( ) 40 25 40 25
40 (kA)( 1 )
Table 40 Short circuit current of Cu & Al conductor(kA)(short circuit time 1s)
Cu Al
Conductor section area Initial temp. of short circuit Initial temp. of short circuit
mm2 35 50 65 80 90 35 50 65 80 90
10 1.81 1.73 1.64 1.57 1.51 1.19 1.13 1.00 1.03 0.986
16 2.87 2.74 2.60 2.49 2.39 1.88 1.80 1.71 1.63 1.56
25 4.45 4.24 4.03 3.85 3.69 2.91 2.78 2.65 2.52 2.42
35 6.20 5.91 5.62 5.37 5.15 4.06 3.88 3.70 3.52 3.37
50 8.81 8.40 7.98 7.62 7.31 5.77 5.51 5.25 5.00 4.79
70 12.30 11.7 11.1 10.6 10.2 8.04 7.69 7.33 6.97 6.68
95 16.60 15.8 15.0 14.4 13.8 10.9 10.4 9.9 9.42 9.03
120 20.90 19.9 19.0 18.1 17.4 13.7 13.1 12.5 11.9 11.4
150 26.10 24.9 23.7 22.6 21.7 17.1 16.3 15.6 14.8 14.2
185 32.10 30.6 29.1 27.8 26.7 21.1 20.1 19.2 18.2 17.5
240 41.60 39.7 37.7 36.0 34.6 27.3 26.0 24.8 23.6 22.6
300 51.90 49.5 47.1 44.9 43.1 34.0 32.5 31.0 29.5 28.2
400 69.10 65.9 62.2 59.8 57.4 45.2 43.2 41.2 39.2 37.6
500 86.40 82.3 78.3 74.7 71.7 56.6 54.0 51.5 49.0 47.0
630 107.0 102.0 96.9 92.5 88.8 70.0 66.9 63.8 60.6 58.0
Ik=I1/ Iktk I11 tktk
Ik=I1/ Iktks short circuit current I11 short circuit current tktk short circuit current
2.2.10.3.2 / ( :kV)
Allowable short circuit current of metal shield/metal sheath(unit:kV)
41 35 kV Table 41 35 kV and below Cu tape shield cable
Circuit
2
Conductor norminal section area mm 1 2 3
Single core cable 0.204a 0.173a 0.141a
3 cores single core cable 0.248a 0.194a 0.158a
2 2
a (mm ) Notes a- Effective section of Cu tape shield(mm )
P26.
2.3 0.6/1kV 0.6/1kV PVC Insulated Power Cable
Executive standards
GB/T12706-2008 1kV(Um=1.2 kV) 35kV(Um=40.5 kV)
The product is designed and made by GB/T12706-2008 Cables with Extruded Insulation and their
Accessories for Ratd Voltage 1kV(Um=1.2 kV)to 35kV(Um=40.5 kV)
2.3.1 Model and It's Name
42 Table 42 Model and Designation
Model Name Application places
VV VLV
PVC Insulated PVC Sheathed Power Cable
VY VLY
PVC Insulated PE Sheathed Power Cable
N-VV
PVC Insulated PVC Sheathed Fire-resistant Power Cable
VV22 VLV22
PVC Insulated PVC Sheathed St.Tape Armored Power Cable
Z-VV22
Z-VLV22 PVC Insulated PVC Sheathed St.Tape Armored Fire-resistant Power Cable
VV23 VLV23
PVC Insulated PE Sheathed St. Tape Armored Power Cable
VV32 VLV32
PVC Insulated PVC Sheathed Thin st. Wires Armored Power Cable
Z-VV32
Z-VLV32 PVC Insulated PVC Sheathed Thin st. Wires Armored flame-retardant Power Cable
N-VV32
PVC Insulated PVC Sheathed Thin st. Wires Armored Fire-resistant Power Cable
Laying in room, mine and water, which
VV33 VLV33 can withstand outer action and pulling.
PVC Insulated PE Sheathed Thin st. Wires Armored Power Cable Flame-retardant cable is forplaces with
requirement.Fire-resistant cable is
VV42 VLV42 PVC Insulated PVC Sheathed thick st. Wires Armored Power Cable forplaces with requirement.
Z-VV42
Z-VLV42 PVC Insulated PVC Sheathed Thick st. Wires Armored flame-retardant Power Cable
N-VV42
PVC Insulated PVC Sheathed Thick st.Wires Armored Fire-resistant Power Cable
P27.
ELECTRIC WIRES & CABLE
Model Explanation
2
Conductor section mm
Core No.
Rated voltage U0/U
Over sheath
Armor
Sheath
Conductor
Insulation
( ) Flame-retardant (fire-resistant)
2.3.2 Spcifications
44 Table 44 Specification
2
Section area mm
Model Core No.
Cu Al
1
VV,VLV,Z-VV,Z-VLV,VV22VV32,VV42,
2
VLV22,VLV32,VLV42,N-VV22,N-VV32, 1.5 400
3 6 300
N-VV42,Z-VV22,Z-VV32,Z-VV42, 2.5 300
Z-VLV22,Z-VLV32,Z-VLV42 3+1
4
VV,VLV,Z-VV,Z-VLV,VV22,VV32,VV42,VLV22, 5
VLV32,VLV42,N-VV22,N-VV32,N-VV42,Z-VV22, 1.5 400 6 300
4+1 2.5 300
Z-VV32,Z-VV42,Z-VLV22,Z-VLV32,Z-VLV42 3+2
2.3.3.3 GB/T3956-2008
DC resistance of conductor agree with the specifications of GB/T3956-2008.
2.3.3.4 0
Surrounding temperature shall not lower than 0 in installing, Min. bending radius refers to table 45.
P28.
45 Table 45 Max. bending radius
Single core cable Multiple core cable
Items
No armor With armor No armor With armor
Min. Bending radius of close with connection 15D 12D 12D 10D
box and terminal cable
D Notes: D Outer diameter of cable
2.3.3.5 Cable laying is not limited by the fall.
2.3.3.6 AC Voltage testing
2.5U0+2kV 5min AC voltage is 2.5U0+2kV, no puncture within 5 min.
2.3.3.7 Flame-retardant
GB/T19666-2005 4
Flame-retardent agree with the specification of bundle feature for GB/T19666-2005 in table 4.
GB/T19666-2005 6 7
Low smoke and low halogen feature agree with the requirement of GB/T19666-2005 in table 6
and the specifications in table 7.
2.3.3.8 Fire-resistant
GB/T19666-2005 5
Fire resistant talies with the specifications of GB/T19666-2005 fire resistant in table 5.
2.3.4 Manufacturing scope of PVC insulated power cable
46 Table 46 Manufacturing scope
P29.
ELECTRIC WIRES & CABLE
Normal insulation thickness and screen in each voltage level refers to the following table.
48 Table 48 Insulation
P30.
1 2.4 kV
4
Dip the insulation wire core removed outer covering inwater for 1 hours, then apply 2.4kV power
frequency voltage between conductor and water and hold on for 4 hours continuously, it's insulation
does not break.
The reference external diameter and weight of common used cable type, such as VV, VLV, VV22,
VLV22 and VV32, VLV32 are listed in table 48 55. All data are not technical parameter checked
by standard, and not checked as contents.
49 Table 49 Single core
Outer diameter mm Weight kg/km
Core No.
section area
mm2 VV VLV VV22 VLV22 VV32 VLV32 VV VLV VV22 VLV22 VV32 VLV32
1 1.5 6.6 55
1 2.5 7.0 68 53
1 4 7.9 92 69
1 6 8.4 115 81
1 10 9.7 12.9 14.4 165 105 293 233 396 315
1 16 10.7 13.9 15.6 229 133 371 274 501 370
1 25 12.0 15.2 17.0 329 177 486 334 656 451
1 35 13.1 16.3 18.3 427 216 598 386 807 521
1 50 14.9 18.1 20.3 565 278 757 470 1022 635
1 70 16.5 19.7 22.1 768 355 979 566 1322 764
1 95 18.6 21.8 24.4 1042 467 1278 703 1725 949
1 120 20.2 23.4 26.2 1275 555 1530 810 2066 1094
1 150 22.4 25.6 28.7 1569 678 1850 959 2498 1295
1 185 24.6 27.8 31.1 1946 834 2253 1140 3042 1539
1 240 27.4 30.6 34.3 2520 1057 2860 1397 3861 1886
1 300 30.2 33.4 37.4 3127 1293 3500 1666 4725 2249
1 400 34.0 38.4 43.0 3966 1626 4742 2402 6402 3243
50 2 Table 50 2 core
Outer diameter mm Weight kg/km
Core No.
section area
mm2 VV VLV VV22 VLV22 VV32 VLV32 VV VLV VV22 VLV22 VV32 VLV32
P31.
ELECTRIC WIRES & CABLE
51 3 Table 51 3 core
Outer diameter mm Weight kg/km
Core No.
section area
mm
2 VV VLV VV22 VLV22 VV32 VLV32 VV VLV VV22 VLV22 VV32 VLV32
52 4 Table 52 4 core
Outer diameter mm Weight kg/km
Core No.
section area
mm2 VV VLV VV22 VLV22 VV32 VLV32 VV VLV VV22 VLV22 VV32 VLV32
P32.
53 5 Table 53 5 core
Outer diameter mm Weight kg/km
Core No.
section area VV VLV VV22 VLV22 VV32 VLV32 VV VLV VV22 VLV22 VV32 VLV32
mm2
5 1.5 12.8 16.0 209 372
5 2.5 13.9 17.1 271 196 446 372
5 4 16.2 19.4 21.7 389 270 593 474 801 640
5 6 17.6 20.8 23.3 503 329 724 550 977 743
5 10 21.1 24.3 27.2 752 448 1015 711 1370 960
5 16 24.0 27.2 30.5 1074 590 1372 888 1852 1199
5 25 27.4 30.8 34.5 1580 815 1933 1168 2610 1577
5 35 30.6 34.0 38.1 2090 1027 2483 1419 3352 1916
5 50 29.4 32.8 36.7 2733 1299 3109 1674 4197 2260
5 70 32.9 36.3 40.7 3761 1691 4179 2109 5642 2847
5 95 38.0 43.0 48.2 5126 2248 6042 3164 8157 4271
5 120 41.2 46.6 52.2 6285 2677 7319 3710 9881 5009
5 150 45.8 51.4 57.6 7763 3302 8929 4468 12054 6032
5 185 51.0 56.8 63.6 9690 4116 11009 5436 14862 7339
5 240 56.5 62.5 70.0 12549 5218 14032 6701 18943 9046
5 300 62.6 68.8 77.1 15669 6480 17336 8147 23404 10998
P33.
ELECTRIC WIRES & CABLE
2.3.8
Continuous load current rating quantity of PVC insulated power cable
2.3.8.1
Laying operation condition of PVC power cable
2.3.8.1.1 Laying in air.
2.3.8.1.1.1 185mm2 2 240mm2 90mm
2
Central distance of single core cable parallel laying it's 90mm for cable of 240mm .
2.3.8.1.1.3 70
Allowable Max. temperature of core:70
2.3.8.1.1.4
Correct factor of current rating under different air temperature
57
Table 57 Current rating factor for different air temperature
Air temperature
Surrounding temperature 20 25 35 40 45
Correct factor 1.12 1.06 0.94 0.87 0.79
P34.
2.3.8.2 Continuous load current rating of cable
Notes:
VV22 VLV22 VV32 VLV32 VV23 VLV23 VV33 VLV33
3 10A
Continuous load current chopping quantity of armor cable VV22, VLV22, VV32, VLV32, VV23, VLV23,
VV33, VLV33 is smaller 3 10A than that without armor with the same specifications, the manual does
not give the current chopping quantity of armor cable, the customer can make calculation up this.
2.3.8.2.1
Allowable current rating in air laying under continuous load conditions
2.3.8.2.2
Allowable current rating of buried laying in long and continuous load condition
P35.
ELECTRIC WIRES & CABLE
1 Application
0.6/1kV
It is suitable for power transmission as power lines with rated voltage 0.6/1kV or lower.
VV-T VLV-T Cu/Al conductor PVC insulated PVC sheathed power cable with concentric conductor
YJV-T YJLV-T Cu/Al conductor XLPE insulated PVC sheathed power cable with concentric conductor
VV22-T VLV 22-T Cu/Al conductor PVC insulated steel tape armored PVC sheathed power cable with concentric conductor
P36.
Model
Designation
Cu Al
Z-VV-T Z-VLV-T
Cu/Al conductor PVC insulated PVC sheathed flame-retardant power cable with concentric conductor
Z-YJV-T Z-YJLV-T
Cu/Al conductor XLPE insulated PVC sheathed flame-retardant power cable with concentric conductor
Z-VV 22-T Z-VLV 22-T Cu/Al conductor PVC insulated steel tape armored PVC sheathed flame-retardant power cable with concentric conductor
Z-VV32-T Z-VLV32-T
Cu/Al conductor PVC insulated thin steel wire armored PVC sheathed flame-retardant power cable with concentric conductor
Z-VV 42-T Z-VLV 42-T Cu/Al conductor PVC insulated thick steel wire armored PVC sheathed flame-retardant power cable with concentric conductor
N-VV-T Cu conductor PVC insulated PVC sheathed fire- resistance power cable with concentric conductor
N-YJV-T Cu conductor XLPE insulated PVC sheathed fire- resistance power cable with concentric conductor
N-VV 22-T Cu conductor PVC insulated steel tape armored PVC sheathed fire- resistance power cable with concentric conductor
N-YJV 22-T Cu conductor XLPE insulated steel tape armored PVC sheathed fire- resistance power cable with concentric conductor
N-VV 32-T Cu conductor PVC insulated thin steel wire armored PVC sheathed fire- resistance power cable with concentric conductor
N-YJV 32-T
Cu conductor XLPE insulated thin steel wire armored PVC sheathed fire- resistance power cable with concentric conductor
N-VV 42-T Cu conductor PVC insulated thick steel wire armored PVC sheathed fire- resistance power cable with concentric conductor
N-YJV 42-T Cu conductor XLPE insulated thick steel wire armored PVC sheathed fire- resistance power cable with concentric conductor
P37.
ELECTRIC WIRES & CABLE
3 Specification
Type
Core No. 2
Cu Al Norminal section of conductor mm
VV-T YJV-T VLV YJLV-T
N-VV-T N-YJV-T
Z-VV-T Z-YJV-T Z-VLV-T Z-YJLV-T
VV22-T YJV22-T VLV22-T YJLV22-T
N-VV22-T N-YJV22-T
3+1(T)
Z-VV22-T Z-YJV22-T Z-VLV22-T Z-YJLV22-T
4+1(T) 4 300
VV32-T YJV32-T VLV32-T YJLV32-T 3+1+1(T)
N-VV32-T N-YJV32-T
Z-VV32-T Z-YJV32-T Z-VLV32-T Z-YJLV32-T
VV42-T YJV42-T VLV42-T YJLV42-T
N-VV42-T N-YJV42-T
Z-VV42-T Z-YJV42-T Z-VLV42-T Z-YJLV42-T
4 Construction of cable
1 1
2 2
3
4 4
5 5
6 6
7 8
8 7
P38.
5.7 ( )
Low and even forward (breckard) and zero sequence impedance improves the quality of power supply.
5.8
Compared with the fourth core of ordinary four power cables, the outer coaxial conductor has a
much lower reactance value when operating in zero sequence, which contributes to the fast action
of automatic short circuit protection so as to ensure the safe operation of cables and related equiptment.
5.9
The complete cable has strong resistance characters against electromagnetic interference and thunder strike.
5.10 GB/T19666-2005
GB/T19666-2005
The combustion character of the cable:
Flame-retardant cable could endure firing test in bundle stipulated in GB/T19666-2005
Fire-resistance cable could endure fire rating in GB/T19666-2005.
The product is used as power supply cable or electric connection for AC rated voltage 0.6/1kV and
below transducing control system. It has strong impulse peformance, which can endure impulse voltage
in transducing. Cable has better shield performance and can eliminate electro-interferance effectively,
reducing motor noise of transducer and ensuring reliable operation of system. It is widely usde in the
fields of metallurgy, power and petrochemical.
2 Operation performance
2.1 U0/U 0.6/1kV
AC rated voltageU0/U 0.6/1kV
2.3 0
PVC sheathed cable no lower than 0 .
2.4 10
Allowable bending radius of cable: Min. cable is 10 times smaller than externial diameter.
BPGGP
Silicon rubber insulated & sheathed copper wire weave shieled transducer power cable with high temperature resistant
BPGGP2 Silicon rubber insulated & sheathed copper tape shielded transducer power cable with high temperature resistant
BPGGPP2 Silicon rubber insulated & sheathed copper wire weave Cu tape shieled transducer power cable with high temperature resistant
BPGGP3
Silicon rubber insulated & sheathed Al polyester composite membrane shieled transducer power cable with high temperature resistant
P39.
ELECTRIC WIRES & CABLE
Model Designation
BPGVFP
Silicon rubber insulated butyronitrile sheathed brass wire weave shieled transducer power cable with high temperature resistant
BPGVFP2
Silicon rubber insulated butyronitrile sheathed Cu tape shieled transducer power cable with high temperature resistant
BPGVFPP2
Silicon rubber insulated butyronitrile sheathed brass wire weave Cu tape shielded transducer power cable with high temperature resistant
BPGVFP3
Silicon rubber insulated butyronitrile sheathed Al polyester composite membrane shielded transducer power cable with high temperature resistant
46
BPFFP
F46 insulated & sheathed brass wire weave shielded transducer power cable with high temperature resistant
46
BPFFP2 F46 insulated & sheathed Cu tape weave shielded transducer power cable with high temperature resistant
46
BPFFPP2 F46 insulated & sheathed brass wire weave Cu tape shielded transducer power cable with high temperature resistant
46
BPFFP3
F46 insulated & sheathed Al polyester composite membrane shielded transducer power cable with high temperature resistant
BPVVP
Silicon rubber insulated & sheathed brass wire weave shielded transducer power cable
BPVVP2
Silicon rubber insulated & sheathed Cu tape shielded transducer power cable
BPVVPP2 Silicon rubber insulated & sheathed brass wire weave Cu tape shielded transducer power cable
BPVVP3
Silicon rubber insulated & sheathed Al polyester composite membrane shielded transducer power cable
BPYJVP XLPE insulated PVC sheathed brass wire weave shielded transducer power cable
BPYJVP2 XLPE insulated PVC sheathed Cu tape shielded transducer power cable
BPYJVPP2 XLPE insulated PVC sheathed brass wire weave Cu tape shielded transducer power cable
BPYJVP3 XLPE insulated PVC sheathed Al polyester composite membrane shielded transducer power cable
Z R
Notes: Brass wire in conductor core can adopt tinning, add Z before flame-retardant type cable and R
before flexible structure cable.
5 Cable specification
Main section area of wire core
2
Model Core No. Norminal section area mm
3+3
4 6 10 16 25 35 50 70 95
All models 3+1 120 150 185 240
1
P40.
Grounding wire core section
2 2
Main wire core norminal section area mm Grounding wire core section area mm
4 1(0.75)
6 1.5(1)
10 2.5(1.5)
16, 25 4(2.5)
35 6
50, 70 10
95 16
120, 150 25
185 35
240 50(35)
P41.
ELECTRIC WIRES & CABLE
3
4
5
6
BPYJVPP2
Structure diagram of BPYJVPP2
3
4
5
6
BPGGPP2
Structure diagram of BPGGPP2
P42.
Overhead Insulation Cable
1kV
Rated voltage 1kV and below overhead insulation cable
2 Using feature
2.1 70 90
The permitted working temperature of cable,conductor in a long time is : For PVC and PE insulated
not be over 70 ; For XLPE insulated should not be over 90
2.2 0
The laying temperature of the cable should not be below 0 .
(1)K
Remarks: 1.K is neutral conductor with supporting. It may be selected in accordance with the requirement
of the project in order to match with the main wire.
P43.
ELECTRIC WIRES & CABLE
5
The electric and the mechanical performance of the cable
1 1kV
Table1:Electrical and mechanical properties of XLPE aerial insulated cable for rated voltage 0.6/1kV.
20
Normal cross- Max.DC resistance of each conductor at 20 /km 90 Min.breaking strength of cable N
sectional area Min.insulation resistance Min.tension strength
2
mm2 at 90 M km of steel wire N/mm
Flexible-copper Cu. Al. Cu. Al.
10kV 35kV
Aerial Insulated Cable With Rated Voltage 10kV or 35 kV
2 Using feature
2.1 ( ) 90 ; 75
The Max permitted working temperature of the cable'sconductor (cable having supporting
structure) is XLPE insulated electric power cable 90 ;HDPE insulated electric power cable 75
2.2 ( 5 ) 250
150
When short circuit(the Max lasting time is not over 5seconds) the Max temperature of the
cable XLPE insulated 250 ;HDPE insulated 150 .
2.3 0
When laying the temperature should not be lower than 0
2.4
The permitted bend radius should not be less than the diameter of cylinder that had been used
for the bend testing
JKYJ
Cu core XLPE aerial insulated cable
JKTRYJ
Soft Cu core XLPE aerial insulated cable
P44.
Type Designation Main Application
JKLYJ/B
Al core with essential color XLPE aerial insulated cable
JKLYJ/Q
Al core light XLPE aerial insulated cable
4 10kV 35kV
The specification aerial insulated Cable with rated voltage 10kV or 35kV
Rated Voltage (kV)
Type 10 35
Number of core
2
Normal Section Area mm
1 10 300 5 300
3 25 300 /
JKYJ JKTRYJ JKLYJ
25 300 /
3+K (A) Or 3+K (B)
K25 120 In which.Kis25 120 /
JKY JKTRY JKLY 1 10 300 /
JKLYJ/Q JKLY/Q 3 25 300 /
25 300 /
JKLYJ/B 3+K (A) Or 3+K (B)
K25 120 In which.Kis25 120 /
(1) K
Remark: (1) In which,K is a supporting twisted wire,ccording to the requirement of the project,the specified
section listed in table may be selected to match with related conctor's section.
(2) (A) (B)
In which,(A) is a steel supporting twisted wire,and (B) is a Al alloy supporting twisted wire.
20
Normal cross- Max.DC resistance of each conductor at 20 /km Min.breaking strength of cable N
sectional area Min.tension strength
mm2 of steel wire N/mm2
Flexible-copper Cu. Al. Cu. Al.
10 1.83 3.08
16 1.15 1.91
25 0.727 0.749 1.20 8465 3762 30000
35 0.524 0.540 0.868 11731 5177 42000
50 0.387 0.399 0.641 16502 7011 56550
70 0.268 0.276 0.443 23461 10354 81150
95 0.193 0.199 0.320 31759 13727 110150
120 0.153 0.158 0.253 39911 17339
150 0.128 0.206 49505 21033
185 0.1021 0.164 61846 26732
240 0.0777 0.125 78923 34679
300 0.0619 0.100 99788 43349
P45.
ELECTRIC WIRES & CABLE
6 ( 2 3 4 5)
Structure,size and weight (Table2 3 4 5)
2 (10kV) ( )
Table2: Structure,size and weight of single-core cable
Normal cross-sectional Normal thickness of Normal thickness Approx.overall Calculating weight Kg/km
area of conductor mm2 conductor screen mm of insulation mm diameter mm
JKYJ JKTRYJ JKLYJ
10 0.5 3.4 12.0 196 121
16 0.5 3.4 13.0 274 153
25 0.5 3.4 14.0 353 178
35 0.5 3.4 15.0 452 237
50 0.5 3.4 16.1 576 284
70 0.5 3.4 17.9 785 364
95 0.6 3.4 19.7 1045 461
120 0.6 3.4 21.1 1283 547
150 0.6 3.4 22.5 1551 643
185 0.6 3.4 24.4 1902 765
240 0.6 3.4 26.6 2446 953
300 0.6 3.4 28.8 3286 1223
3 (10kV)
Table3: Structure,size and weight of three-core cable
Normal cross-sectional Normal thickness of Normal thickness Normal thickness of Approx.overall Calculating weight Kg/km
area of conductor mm2 conductor screen mm of insulation mm insulation screen mm diameter mm
JKYJ JKTRYJ JKLYJ
3 25 0.5 3.4 1.0 34.2 1081 545
3 35 0.5 3.4 1.0 36.3 1384 726
3 50 0.5 3.4 1.0 38.7 1764 870
3 70 0.5 3.4 1.0 42.6 2401 1115
3 95 0.6 3.4 1.0 46.4 3201 1412
3 120 0.6 3.4 1.0 49.4 3930 1675
3 150 0.6 3.4 1.0 52.5 4751 1970
3 185 0.6 3.4 1.0 56.1 5826 2434
3 240 0.6 3.4 1.0 61.3 7492 2919
3 300 0.6 3.4 1.0 66.0 10065 3746
4 (35kV)
Table 4: (35kV) structure, size and weight of single core cable
Normal cross-sectional Normal thickness of Normal thickness Approx.overall Calculating weight kg/km
area of conductor mm2 conductor screen mm of insulation mm diameter mm
JKYJ JKTRYJ JKLYJ
1 50 0.8 9.3 27.0 993 680
1 70 0.8 9.3 29.0 1227 789
1 95 0.8 9.3 30.0 1500 905
1 120 0.8 9.3 32.0 1768 1016
1 150 0.8 9.3 33.0 2080 1140
1 185 0.8 9.3 35.0 2446 1287
1 240 0.8 9.3 37.0 3013 1510
1 300 0.8 9.3 39.0 3620 1740
P46.
5: (3 K)
Table5: Structure, size and weight of (3 K)cable
Normal cross- Normal thickness Normal thickness Normal thickness Normal thickness Size of Size of Calculating weight
sectional area of conductor screen of insulation of insulation screen Of sheath lashing wire cables Kg/km
of conductor mm mm mm mm mm mm
mm2 JKTRYJV JKLYJV
25 0.7 4.5 0.7 1.7 3.0 6.0 52 50 2049
35 0.7 4.5 0.7 1.7 3.0 6.0 55 51 2833 2174
50 0.7 4.5 0.7 1.8 3.0 6.0 59 54 3424 2532
70 0.7 4.5 0.7 1.8 3.0 6.0 64 57 4318 3031
95 0.7 4.5 0.7 1.9 3.0 6.0 69 63 5426 3638
120 0.7 4.5 0.7 1.9 3.0 6.0 73 64 6236 3980
150 0.7 4.5 0.7 2.0 3.0 6.0 77 67 7171 4388
185 0.7 4.5 0.7 2.0 3.0 6.0 82 70 8230 4748
240 0.7 4.5 0.7 2.1 3.0 6.0 89 76 10084 5511
2 2 2
:25--95 mm ; 95 mm 95 mm
Note:The cross-sectional area of steel messenger wire can be equivalent to the cross-sectional drea of the
2 2 2
main conductor for 25 95 mm the cross-sectional area of steel wire can be over 95 mm in excess of 95 mm
6: 1kV. 10kV
Table 6: Current-ratings of aerial cables with XLPE insulation for rated voltages up to 1kV 10kV.
: (A) Unit:(A)
type JKYJ-0.6/1kV JKTRYJ-0.6/1 kV JKLYJ-0.6/1 kV JKTRYJV-10 kV JKLYJV-10 kV
core No single-core Three-core 3+K
P47.
ELECTRIC WIRES & CABLE
The prefabricate branch cable made by our company complies with standard JB/T10636-2006
Prefabricated Branch Cable of Rated Voltage 0.6/1kV Cu Core Plastic Insulation .It is used in
residence, high-rising building, tunnel and works..
2 Technical Performance
2.1 : 3.5kV, 5min ; AC withstand voltage: 3.5kV, no puncture for 5 min;
2.2 : 200M ; Insulation resistance: 200M ;
2.3 : 1.2; Ratio of branch joint resistance: 1.2;
2.4 : 0.2;
Short circuit test: change ratio of DC resistance after short circuit 0.2;
2.5 : 25 75 , 26-125 25 +8 ;
Thermal cycle test: Measured value for 25th period 75 , the measured value for 26-125 period
is smaller than+8 , the value of temperature rise of 25th period.
3
Cable model, designation and manufacturing scope
Prefabricate branch cable
2
Norminal section area mm
Type Designation Core No.
Main cable Brance cable
FZ-ZRVV
Cu core PVC Insulated PVC sheathed fire-resistant prefibricate branch cable
2 3 16 300 2.5 150
FZ-NHVV
Cu core PVC insulated PVC sheathed fire-resistant prefibricate branch cable
FZ-YJV
Cu core XLPE insulated PVC sheathed prefibricate branch cable
4 16 185 2.5 95
FZ-ZRYJV
Cu core XLPE insulated PVC sheathed flame-retardant prefibricate branch cable
4
Main advantages of prefabricate branch cable
4.1 With better reliability in safe power supply
4.1.1 ,
Conductor of main cable has no joints, better in continuity to reduce trouble point.
4.1.2
Branch joints adopt all mechanical process, reducing greatly phenomena of quality from person.
4.1.3 , ,
It's reasonable for structure of branch joints, small for contact resistance, no effect on expanding
with heat and contracts with cold.
4.2
It's economy, can reduce distinctly the cost of distribution power.
To save construction laboring, total engineering cost, including personnel and material are cut down.
4.4.3 , It's easy in assembling to reduce construction period.
P48.
, ,
Assembling device needs only one common windlass, a great of work on site is done in works,
laboring time on construction sites is saved.
4.4.4 , It's easy for on-site management, free maintenance.
, ;
One time opening rate in success is high, after prefabricate cable is assembled according to stipulations;
branch cable system doesn't need any repair in normal operation.
4.4.5
Better antinock, airtightness, waterproofness and Flame-retardant
NH
750~1000 90min
The branch joints and upper support are airtightness and waterproofness, which can be used in damp
areas. The branch cable with NH type can operate normally for 90 min. under 750--1000 .
5 Ordering
Control Cable
1 Executive Standards
GB/T9330 2008
GB/T19666-2005
It is manufactured according to GB/T9330-2008 standards
The low-smoking low-halogen low-smoking halogen-free flame-retardant cable , it complies with
GB/T19666-2005standards.
2 Application
(Uo/U)450/750V
It is used for the signal transmission controlling and measuring system of the electric apparatus
and the power distribute apparatus in the field of metallurgy,power and petrochemistry. Its rated
voltage (Uo/U)is up to including 450/750V.
P49.
ELECTRIC WIRES & CABLE
KVV
PVC insulated PVC sheathed control cable
KYY
PE insulated PE sheathed control cable
KYV
PE insulated PVC sheathed control cable
KYJV
XLPE insulated PVC sheathed control cable
KVVP
PVC insulated PVC sheathed copper wire braided screen control cable
KYYP
PE insulated PE sheathed copper wire braided screen control cable
KYVP PE insulated PVC sheathed copper wire braided screen control cable
KYJVP
XLPE insulated PVC sheathed copper wire braided screen control cable
KVVP2
PVC insulated PVC sheathed copper tape wrapped screen control cable
KYYP2
PE insulated PE sheathed copper tape wrapped screen control cable
KYVP2 PE insulated PVC sheathed copper tape wrapped screen control cable
KYJVP2
XLPE insulated PVC sheathed copper tape wrapped screen control cable
KYJVP3 XLPE insulated PVC sheathed Al/plastic wrapped screen control cable
KVV22 PVC insulated PVC.sheathed double steel tape armoured control cable
KYV22 PE insulated PVC sheathed double steel tape armoured control cable
KYJV22 XLPE insulated PVC sheathed double steel tape armoured control cable
KVVRP PVC insulated PVC sheathed copper wire braided screen flexible control cable
KYYRP PE insulated PE sheathed copper wire braided screen flexible control cable
P50.
Model Designation
KYVRP
PE insulated PVC sheathed copper wire braided screen flexible control cable
KYJVRP
XLPE insulated PVC sheathed copper wire braided screen flexible control cable
Z-KVV
PVC insulated PVC sheathed control cable flame retardant
Z-KYY
PE insulated PE sheathed control cable flame retardant
Z-KYJV
XLPE insulated PVC sheathed control cable flame retardant
Z-KVVP
PVC insulated PVC sheathed copper wire braided screen control cable flame retardant
Z-KYVP PE insulated PVC sheathed copper wire braided screen control cable flame retardant
Z-KYJVP
XLPE insulated PVC sheathed copper wire braided screen control cable flame retardant
Z-KVVP2
PVC insulated PVC sheathed copper tape wrapped screen control cable flame retardant
Z-KYVP2
PE insulated PVC sheathed copper tape wrapped screen control cable flame retardant
Z-KYJVP2 XLPE insulated PVC sheathed copper tape wrapped screen control cable flame retardant
Z-KVVP3
PVC insulated PVC.sheathed Al/plastic wrapped screen control cable flame retardant
Z-KYVP3 PE insulated PVC.sheathed Al/plastic wrapped screen control cable flame retardant
Z-KYJVP3 XLPE insulated PVC sheathed Al/plastic wrapped screen control cable flame retardant
Z-KVV22 PVC insulated PVC sheathed double steel tape armoured control cable flame retardant
Z-KYV22 PE insulated PVC sheathed double steel tape armoured control cable flame retardant
Z-KYJV22 XLPE insulated PVC sheathed double steel tape armoured control cable flame retardant
Z-KVVR PVC insulated PVC sheathed flexible control cable flame retardant
Z-KYJVR XLPE insulated PVC sheathed flexible control cable flame retardant
Z-KVVRP PVC insulated PVC sheathed copper wire braided screen flexible control cable flame retardant
Z-KYVRP PE insulated PVC sheathed copper wire braided screen flexible control cable flame retardant
Z-KYJVRP XLPE insulated PVC sheathed copper wire braided screen flexible control cable flame retardant
DDZ-KVV PVC insulated PVC sheathed control cable low-smoking low-halogen flame retardant
DDZ-KYV PE insulated PVC sheathed control cable low-smoking low-halogen flame retardant
DDZ-KYJV XLPE insulated PVC sheathed control cable low-smoking low-halogen flame retardant
DDZ-KVVP PVC insulated PVC sheathed control wire braided common shield control cable low-smoking low-halogen flame retardant
P51.
ELECTRIC WIRES & CABLE
Model Designation
DDZ-KYVP
PE insulated PVC sheathed control wire braided common shield control cable low-smoking low-halogen flame retardant
DDZ-KYJVP
XLPE insulated PVC sheathed control wire braided common shield control cable low-smoking low-halogen flame retardant
DDZ-KVVP2
PVC insulated.PVC.sheathed copper tape wrapped common shield control cable low-smoking low-halogen flame retardant
DDZ-KYVP2
PE insulated PVC sheathed copper tape wrapped common shield control cable low-smoking low-halogen flame retardant
DDZ-KYJVP2
XLPE insulated PVC sheathed copper tape wrapped common shield control cable low-smoking low-halogen flame retardant
DDZ-KVVP3
PVC insulated PVC sheathed Al/plastic wrapped common shield control low-smoking low-halogen flame retardant
DDZ-KYVP3 PE insulated PVC sheathed Al/plastic wrapped common shield control low-smoking low-halogen flame retardant
DDZ-KYJVP3
XLPE insulated PVC sheathed Al/plastic wrapped common shield control low-smoking low-halogen flame retardant
DDZ-KVVP22
PVC insulated PVC sheathed double steel tape armoured control cable low-smoking low-halogen flame retardant
DDZ-KYVP22
PE insulated PVC sheathed double steel tape armoured control cable low-smoking low-halogen flame retardant
DDZ-KYJVP22 XLPE insulated PVC sheathed double steel tape armoured control cable low-smoking low-halogen flame retardant
DDZ-KVVR
PVC insulated PVC sheathed flexible control cable low-smoking low-halogen flame retardant
DDZ-KYVR PE insulated PVC sheathed flexible control cable low-smoking low-halogen flame retardant
DDZ-KYJVR XLPE insulated PVC sheathed flexible control cable low-smoking low-halogen flame retardant
DDZ-KVVRP PVC insulated PVC sheathed copper wire braided common shield flexible control cable low-smoking low-halogen flame retardant
DDZ-KYVRP PE insulated PVC sheathed copper wire braided common shield flexible control cable low-smoking low-halogen flame retardant
DDZ-KYJVRP XLPE insulated PVC sheathed copper wire braided common shield flexible control cable low-smoking low-halogen flame retardant
WDZ-KYJY XLPE insulated PO sheathed control cable low-smoking halogen-free flame retardant
WDZ-KYJYP XLPE insulated PO sheathed copper wire braided common shield control cable low-smoking halogen-free flame retardant
WDZ-KYYP PO insulated PO sheathed copper wire braided common shield control cable low-smoking halogen-free flame retardant
WDZ-KYJYP2 XLPE insulated PO sheathed copper tape wrapped common shield control cable low-smoking halogen-free flame retardant
WDZ-KYYP2 PO insulated PO sheathed copper tape wrapped common shield control cable low-smoking halogen-free flame retardant
WDZ-KYJYP3 XLPE insulated PO sheathed Al/plastic wrapped common shield control cable low-smoking halogen-free flame retardant
WDZ-KYYP3 PO insulated PO sheathed Al/plastic wrapped common shield control cable low-smoking halogen-free flame retardant
WDZ-KYJY23 XLPE insulated PO sheathed double steel tape armoured control cable low-smoking halogen-free flame retardant
WDZ-KYY23
PO insulated PO sheathed double steel tape armoured control cable low-smoking halogenfree flame retardant
P52.
Model Designation
WDZ-KYJYR
XLPE insulated PO sheathed flexible control cable low-smoking halogen-free flame retardant
WDZ-KYYR
PO insulated PO sheathed flexible control cable low-smoking halogen-free flame retardant
WDZ-KYJYRP
XLPE insulated PO sheathed copper wire braided common shield flexible control cable low-smoking halogen-free flame retardant
WDZ-KYYRP
PO insulated PO sheathed copper wire braided common shield flexible control cable low-smoking halogen-free flame retardant
5 Model Explanation
2
Nominal sectional area(mm )
Core No.
Heat-resistance grade
Over sheath
Armor
shield
kind of conductor
sheathed
Insulation
senes code
Flame-retardant code
2
() 10mm ,A , ,B-
Remarks ( ) means the class conductor when its nominal area is less than 10mm2 ,A means solid conductor,
Can be omitted,B means it is stranded conductor.
P53.
ELECTRIC WIRES & CABLE
6 Indication Examples
(B)
The indication of plastic insulated control cable consists of type,number of cores,nominal sectional
area of conductor,When the same type product is made of different class of conductor the more
flexible one is indicated with (B) following the specitication.For exampies
2
6.1 16 2.5mm
:KVV 16 2.5 :KVV 16 2.5(B)
2
PVC insulated PVC sheathed control cable, 16 cores, nominal sectional area is 2.5mm is indicated
with The harder one: KVV 16 2.5 The more flexible one: KVV 16 2.5(B)
6.2 12
2
4mm :
Z-KYJV22 12 4
XLPE insulated PVC sheathed double steel tape armoured control cable flame retardant
2
12cores nominal sectional area is 4mm , is indicated with:
Z-KYJV22 12 4
7
Using feature &Main Technical Performances
7.1 (UO/U):450/750V Rated voitage(UO/U): 450/750V;
7.2
70 90
The Max. long-term operating temperature of conductor:
PEinsulated cable:70 XLPE insulated cable 90
:70 90 ( );
PVC insulated cable: 70 90 (according to the grade of heat proof after the type)
: 70 ,90 ( );
low-smoking halogen-free flame retardant PO insulated cable 70 90 (according to the
grade of heat proof after the type)
7.3 20
:0 ( )
The Min.laying temperature is: 20 for PE sheathed cable 0 for PVC or HFPO sheathed
cable . (It should be preheated if it is below the Min.laying temperature).
7.4 :
12 6
The permitted bending radius:
No less than 12 times of the overall diameter of the cable for which has armor or copper tape
wrapped shield.No less than 6 times of the overall diameter of the cable for the others.
P54.
7.6 3 4
The D.C resistance of conductor is show in table 3 and the insulation resistance is show in table 4.
3 table 3
20
D.C. resistance of conductor at 20 /km
Nominal
section area Untinned Tinned
2
mm
A Kind A B Kind B Flexible A Kind A B Kind B Flexible
0.5 36.0 36.0 39.0 36.7 36.7 40.1
0.75 24.5 24.5 26.0 24.8 24.8 26.7
1.0 18.1 18.1 19.5 18.2 18.2 20.0
1.5 12.1 12.1 13.3 12.2 12.2 13.7
2.5 7.41 7.41 7.98 7.56 7.56 8.21
4 4.61 4.61 4.70 4.70
6 3.08 3.08 3.11 3.11
10 1.83 1.84
4 table 4
70 90
Insulation resistance at 70 or 90 M km
Nominal
section area PEor XLPE insulated PVCorHFPO insulated
mm2
A Kind A B Kind B Flexible A Kind A B Kind B Flexible
0.5 0.1400 0.1300 0.1300 0.014 0.014 0.013
0.75 0.1200 0.1100 0.1100 0.012 0.014 0.011
1.0 0.1100 0.1000 0.1000 0.011 0.013 0.010
1.5 0.1100 0.1000 0.1000 0.011 0.010 0.010
2.5 0.1000 0.0900 0.0900 0.010 0.009 0.009
4 0.0850 0.0700 0.0085 0.0077
6 0.0700 0.0650 0.0070 0.0065
10 0.0650 0.0065
8 Manufacturing scope
mm2 Conductor nominal cross-section area mm2
Type 0.5 0.75 1.0 1.5 2.5 4 6 10
Core No.
P55.
ELECTRIC WIRES & CABLE
2 Brief Introduction
450/750V
1 BV-90 RV-90 90
70 121
The product is used in power connection of household electrical appliance, small electrical tool, apparatus
& meter and power lightening under AC rated voltage 450/750 kV, the mode, name and manufacturing
scope refer to table 1. Besides working temperature of BV-90, RV-90 is 90 , other cables are 70
Short time withstand current temperature of nylon sheath wire & cable is 121 for long time.
2
Model Rated voltage(V) Name Core Number Scope mm
227IEC01(BV) 450/750 Cu core PVC insulated cable 1 1.5-400
227IEC07(BV-90) 300/500 90
1 0.5-2.5
PVC insulated cable with temp of Cu core conductor is 90
90
227IEC08(RV-90) 300/500 1 0.5-2.5
PVC insulated flexible cable with temp of Cu core conductor is 90
AV 300/300 1 0.08-0.4
Cu core PVC insulated fit wire
90
AV-90 300/300 PVC insulated fit wire with temp of Cu core withstand temp is 90 1 0.08-0.4
P56.
2
Model Rated voltage(V) Name Core No. Scope mm
90 1
AVP-90 300/300 0.08-0.4
PVC insulated fit shielded cable with temp of Cu core withstand temp is 90
BLV 450/750 Al core PVC insulated wire 1 2.5-400
ZR-BV 450/750 Common single core H conductor no-sheathed cable flame-retardant 1 1.5-400
70
ZR-BV-70 300/500 Single core solid conductor, no sheathed flame-retardant cable with 1 0.5-1.0
temp. of inter.laying conductor is 70
70
ZR-RV-70 300/500 Single core flexible conductor, no sheathed flame-retardant cable 1 0.5-1.0
with temp. of inter.laying conductor is 70
90
ZR-BV-90 300/500 Single core solid conductor, no sheathed flame-retardant cable 1 0.5-2.5
with temp. of inter.laying conductor is 90
90
ZR-RV-90 300/500 Single core flexible conductor, no sheathed flame-retardant cable 1 0.5-2.5
with temp. of inter.laying conductor is 90
P57.
ELECTRIC WIRES & CABLE
2
Model Rated voltage(V) Name Core No. Scope mm
ZR-RVVP 300/300 Cu core PVC insulated sheathed PVC sheathed flame 1 0.08-2.5
-retardant flexible wire
70
NH-BV-70 300/500 Single core solid conductor, no sheathed fire-resistant cable 1 0.5-1.0
with temp of inter.laying conductor is 70
2 Technical Performance
2.1 YZ 300/500V,YC 450/750V YH
Rated voltage of YZ type is 300/500V, YC type is 450/750V. No stipulation is made for YH type.
2.2 60 Long working temperature of cable is 60 .
2.3 W
W type derived cable is with anti-weather and certain anti-oil performance, which is used in
places of outdoor touching oil stain.
P58.
3
Model, designation and manufacturing scope of cable
YQ
300/300V Lightrubber tube 2-3 0.3-0.5
YQW For light mobile apparatus and tool
flexible cable
2-5 0.75-2.5
Common stength
245IEC53(YZ) rubber tube flexible
wire
YZ 2-5 4-6
Medium rubber
YZW flexible cable 3+1 1.5-6
1 1.5-400
2 1.5-95
YC 450/750V 3 4 1.5-150
5 1.5-25
Heavy rubber For each light mobile apparatus,
flexible cable 3+1 2.5-150 can withstand larger mechanical
2 35-95 force outside.
245IEC66(YCW)
450/750V 3 120-150
YCW
3+1 2.5-150
P59.
ELECTRIC WIRES & CABLE
,
MYQ-0.3/0.5 kV
Mobile light rubber tube flexible Connection for lane lightening of mine, conveyor interlocking and
cable for mine control & signal device power
MZP-0.3/0.5 kV 0.3/0.5kV
Electric drill sheahted rubber
tube cable for mine Power connection of drill for rated voltage 0.3/0.5kV and below for mine
0.3/0.5kV
MZ-0.3/0.5 kV Electric drill rubber tube cable Power connection of drill for rated voltage 0.3/0.5kV and below for mine
for mine
0.38/0.66kV
MC-0.38/0.66 kV Coal winning machine rubber Power connection of rated voltage 0.38/0.66kV coal winning machine
tube flexible cable and similar devices
0.66/1.14kV
MCP-0.66/1.14 kV Coal winning machine sheathed Power connection of rated voltage 0.38/1.14kV coal winning machine
rubber tube flexible cable and similar devices
0.38/0.66kV
MCP-0.38/0.66 kV Coal winning machine sheathed Power connection of rated voltage 0.38/0.66kV coal winning machine
rubber tube flexible cable and similar devices
1.9/3.3kV
MCP-1.9/3.3 kV Coal winning machine sheathed Power connection of rated voltage 1.9/3.3kV coal winning machine
rubber tube flexible cable and similar devices
0.38/0.66kV
MY-0.38/0.66 kV Mobile rubber tube flexible
cable for mine Power connection of rated voltage 0.38/0.66kV each movible coal winning machines
0.38/0.66kV
MYP-0.38/0.66 kV Mobile rubber tube flexible Power connection of rated voltage 0.38/0.66kV each movible coal
cable for mine winning machines
0.66/1.14kV
MYP-0.66/1.14 kV Mobile rubber tube flexible Power connection of rated voltage 0.66/1.14kV each movible coal
cable for mine winning machines
3.6/6kV
MYPTJ-3.6/6 kV Mobile metal sheathed monitor Power connection of rated voltage 3.6/6kV movible
type rubber tube flexible cable transformer and similar devices
for mine
1.2
Construction and main technical data
1.2.1
Flexible light rubber-sheathed cables for mine
Model: MYQ Rated Voltage: 0.3/0.5 kV
P60.
External dia. of cable ( ) 20
Core No.of Insulation Ref. Weight Max.DC resistance of Current rating
section area thickness conductor(Cu) in 20
Sheath thickness Norminal
mm
Conductor
Rubber insulation
Rubber sheath
1) , +20 160M km
2) MT818.9-1999
3) MYQ , 2 12
4) GB/T3956-1997
5) GB7594.2-1987 XJ-00A
6)
7)
8) GB7594.5-1987 XH-01A
9)
(1) The insulation resistance, between main cable dielectric cores and for main cores and
grounding wire, is not lower than 160M km when conversion into +20
(2) Product standard: MT818.9-1999.
(3) MYQ type cable is consists of 2 12 main cores, extruded black chlorinated PE rubber sheath
or black neoprene from outside after cabling.
(4) Conductive core: adopting flexible Cu wire, the performance talies with GB/T3956-1997.
(5) Insulation: adopting XJ-00A type rubber in GB7594.2-1987.
(6) Wire core indentify: Four-core and below adopts insulation color separation indentified;
main wire is red, white, light blue, grounding wire is black. Four-core above adopts pringting
No. To indentify.
(7) Cabling: Stranding into cable by right direction.
(8) Sheath: adopting XH-01A type rubber in GB7594.2-1987.
(9) Cable sign: Model, voltage, specification and manufacturing works are printed on cable surface.
P61.
ELECTRIC WIRES & CABLE
Overall diameter ( ) 20
Nor.cross Insulation Sheath Current
sectional thickness thickness Ref. weight Max.D.C.resistance rating
min Max
areas mm2 mm mm kg/km of conductor (Cu) (20 )A
mm mm
in 20 /km
0.565
3 35+1
2.8 6 47.2 51.4 3758 1.24 138
16+3 2.5
8.21
0.393
3 50+1
2.8 7 54.3 58.6 4888 0.795 170
25+3 6
3.39
0.277
3 70+1
3.0 7 59.6 64.3 5783 0.565 210
35+3 6
3.39
0.210
3 95+1
3.0 7 64.5 70.1 7430 0.393 250
50+3 10
1.95
Conductor
Rubber insulation
Semi-conductor Screen
Ground Wire
Semi-conductor Filler
Control cables
Rubber sheath
Notes
1 +20 100M km
2 20 3k
3 MT818.2-1999
4 MCP 3 ( 3 )
5 GB/T3956-1997
6 GB7594.8-1987 XJ-30A
7
8
9
10
11 GB7594.7-1987 XH-03A
12 MCP MT386-1995
13
(1) The insulation resistance, between main cable dielectric cores and for main cores and grounding
wire, is not lower than 100M km when conversion into +20
(2) Transition resistance of main core screen layer is not over 3k when conversion into 20 .
(3) Product standard: MT818.2-1999.
P62.
(4) MCP type cable is consists of 3 main cores, 1 grounding core and a group of control unit (control
unit 3 cores), wrapped black chlorinated PE rubber sheath or black neoprene from outside after
cabling.
(5) Conductive core: adopting tinning flexible Cu wire, the performance talies with GB/T3956-1997.
(6) Insulation: adopting XJ-30A type rubber in GB7594.8-1987.
(7) Wire core indentify: adopting insulation color separation distinquishing; main wire is red, white, light
blue, grounding wire is black. Control wire is printed with number.
(8) Insulation screen: Conductive rubber is covered in the service.
(9) Grounding wire: Wrapped conductive tape on insulation surface.
(10) Cabling: Stranding into cable by right direction. Put core in center to without control unit. Put
grounding wire in center with control unit.
(11) Sheath: adopting XH-03A type rubber in GB7594.7-1987.
(12) Flame-retardant performance of finished product for MCP type satisfies the requirement of MT386
-1995.
(13) Cable sign: Model, voltage, specification and manufacturing works are printed on cable surface.
1.2.3 Coal winning machine sheathed rubber tube flexible coal
Type: MCP Rated Voltage: 0.66/1.14 kV
Overall diameter ( ) 20
Nor.cross Insulation Sheath Current
sectional thickness thickness Ref. weight Max.D.C.resistance rating
min Max
areas mm2 mm mm kg/km of conductor (Cu) (20 )A
mm mm
in 20 /km
0.565
3 35+1
2.0 6 47.2 51.4 3758 3.39 138
6+3 6
3.39
0.393
3 50+1
2.2 7 54.3 58.6 4888 1.95 170
10+3 6
3.39
0.277
3 70+1
2.2 7 59.6 64.3 5783 1.24 210
16+3 6
3.39
0.210
3 95+1
2.4 7 64.5 70.1 7430 0.795 250
25+3 10
1.95
Conductor
Rubber insulation
Semi-conductor Screen
Ground Wire
Semi-conductor Filler
Control cables
Rubber sheath
Notes
1 , +20 100M km
2 20 3k
3 MT818.2-1999
4 MCP 3 ( 3 )
5 GB/T3956-1997
P63.
ELECTRIC WIRES & CABLE
6 GB7594.2-1987 XJ-00A
7
8
9
10
11 GB7594.7-1987 XH-03A
12 MCP MT386-1995
13
(1) The insulation resistance, between main cable dielectric cores and for main cores and grounding
wire, is not lower than 100M km when conversion into +20
(2) Transition resistance of main core screen layer is not over 3k, when conversion into 20 .
(3) Product standard: MT818.2-1999.
(4) MCP type cable is consists of 3 main cores, 1 grounding core and a group of control unit (control
unit 3 cores), wrapped yellow chlorinated PE rubber sheath or yellow neoprene from outside after
cabling.
(5) Conductive core: adopting tinning flexible Cu wire, the performance talies with GB/T3956-1997.
(6) Insulation: adopting XJ-00A type rubber in GB7594.2 1987.
(7) Wire core distinquishing: adopting insulation color separation distinquishing; main wire is red, white,
light blue, grounding wire is black. Control wire is printed with number.
(8) Insulation screen: Conductive rubber is covered in the service.
(9) Grounding wire: Wrapped conductive tape on insulation surface.
(10) Cabling: Stranding into cable by right direction. Put core in center to without control unit. Put
grounding wire in center with control unit.
(11) Sheath: adopting XH-03A type rubber in GB7594.7-1987.
(12) Flame-retardant performance of finished product for MCP type satisfies the requirement of MT386
-1995.
(13) Cable sign: Model, voltage, specification and manufacturing works are printed on cable surface.
Overall diameter ( ) 20
Nor.cross Insulation Sheath Current
sectional thickness thickness Ref. weight Max.D.C.resistance chopping
min Max
areas mm2 mm mm kg/km of conductor (Cu) (20 )A
mm mm
in 20 /km
1.24
3 16+1
1.6 4.5 33.2 36.5 1883 5.09 85
4+3 2.5
8.21
0.795
3 25+1
1.8 5.5 40.3 44.3 2571 3.39 113
6+4 2.5
8.21
0.565
3 35+1
1.8 5.5 45.8 50.4 3527 3.39 138
6+4 4
5.09
0.393
3 50+1
2.0 5.5 51.5 55.0 4400 1.95 170
10+4 4
5.09
Conductor
Rubber insulation
Semi-conductor Screen
Ground Wire
Semi-conductor Filler
Control cables
Rubber sheath
P64.
Notes
1) , +20 100M km
2) 20 3k
3) MT818.2-1999
4) MCP , 3 ( 2 3 4 7 )
5) GB/T3956-1997
6) GB7594.2-1987 XJ-00A
7)
8)
9)
10)
11) GB7594.7-1987 XH-03A
12) MCP MT386-1995
13)
(1) The insulation resistance, between main cable dielectric cores and for main cores and grounding
wire, is not lower than 100M km when conversion into +20
(2) Transition resistance of main core screen layer is not over 3k when conversion into 20 .
(3) Product standard: MT818.2-1999.
(4) MCP type cable is consists of 3 main cores, 1 grounding core and a group of control unit (control
unit 2, 3,4,7 cores), wrapped black chlorinated PE rubber sheath or black neoprene from outside after
cabling.
(5) Conductive core: adopting tinning flexible Cu wire, the performance talies with GB/T3956-1997.
(6) Insulation: adopting XJ-00A type rubber in GB7594.2 1987.
(7) Wire core distinquishing: adopting insulation color separation distinquishing; main wire is red, white,
light blue, grounding wire is black. Control wire is printed with number.
(8) Insulation screen: Conductive rubber is covered in the service.
(9) Grounding wire: Wrapped conductive tape on insulation surface.
(10) Cabling: Stranding into cable by right direction. Put core in center to without control unit. Put
grounding wire in center with control unit.
(11) Sheath: adopting XH-03A type rubber in GB7594.7-1987.
(12) Inflam-retardant performance of finished product for MCP type satisfies the requirement of MT386
-1995.
(13) Cable sign: Model, voltage, specification and manufacturing works are printed on cable surface.
Overall diameter ( ) 20
Nor.cross Insulation Sheath Ref. weight Current
sectional thickness thickness kg/km Max.D.C.resistance rating
min Max
areas mm
2 mm mm of conductor (Cu) (20 )A
mm mm
in 20 /km
1.21
3 16+1 4+3 2.5 1.6 4.5 31.3 34.4 1668 4.95 85
7.98
0.78
3 25+1 6+4 2.5 1.8 5.5 38.4 41 2324 3.3 113
7.98
0.554
3 35+1 6+4 4 1.8 5.5 43.9 48.3 3234 3.3 138
4.95
0.386
3 50+1 10+7 4 2 5.5 47.7 51 4080 1.91 170
4.95
P65.
ELECTRIC WIRES & CABLE
Conductor
Rubber insulation
Ground Wire
Control cables
Rubber sheath
Notes
1) , +20 100M km
2) GB818.2-1999
3) MC 3 ( 2 3 4 7 )
4) GB/T3956-1997
5) GB7594.2-1987 XJ-00A
6)
7)
8) GB7594.7-1987 XH-03A
9) MC MT386-1995
10)
(1) The insulation resistance, between main cable dielectric cores and for main cores and grounding
wire, is not lower than 100M km when conversion into +20
(2) Product standard: MT818.2-1999.
(3) MC type cable is consists of 3 main cores, 1 grounding core and a group of control unit (control
unit 2, 3 4, 7 cores), wrapped black chlorinated PE rubber sheath or black neoprene from outside after
cabling.
(4) Conductive core: adopting tinning flexible Cu wire, the performance talies with GB/T3956-1997.
(5) Insulation: adopting XJ-00A type rubber in GB7594.2 1987.
(6) Wire core distinquishing: adopting insulation color separation distinquishing; main wire is red, white,
light blue, grounding wire is black. Control wire is printed with number.
(7) Cabling: Stranding into cable by right direction. Put core in center to without control unit. Put
grounding wire in center with control unit.
(8) Sheath: adopting XH-03A type rubber in GB7594.7-1987.
(9) Flame-retardant performance of finished product for MCP type satisfies the requirement of MT386
-1995.
(10) Cable sign: Model, voltage, specification and manufacturing works are printed on cable surface.
Overall diameter ( ) 20
Nor.cross Insulation Sheath Current
sectional thickness thickness Ref. weight Max.D.C.resistance rating
min Max
areas mm2 mm mm kg/km of conductor (Cu) (20 )A
mm mm
in 20 /km
1.91
3 10+1 10 1.8 4.5 31.7 34.9 1640 64
1.91
1.21
3 16+1 10 1.8 4.5 34.2 37.6 1899 85
1.91
0.78
3 25+1 16 2 5 40.3 44.3 2648 113
1.21
0.554
3 35+1 16 2 5 44.4 48.8 3201 138
1.21
P66.
Overall diameter ( ) 20
Nor.cross Insulation Sheath Current
sectional thickness thickness Ref. weight Max.D.C.resistance rating
min Max
areas mm2 mm mm kg/km of conductor (Cu) (20 )A
mm mm
in 20 /km
0.386
3 50+1 16 2.2 5.5 51.5 54.6 4013 173
1.21
0.272
3 70+1 25 2.2 5.5 53.9 59.3 5079 215
0.78
0.206
3 95+1 25 2.4 6 62.1 68.1 6280 260
0.78
Conductor
Rubber insulation
semi-conductor filler
semi-conductor screen
Rubber sheath
Notes
1) , +20 100M km
2) 20 3k
3) MT818.5-1999.
4) MYP 3
5) GB/T3956-1997
6) GB7594.2-1987 XJ-00A
7)
8)
9)
10) 3
11) GB7594.7-1987 XH-03A 40
12) MT386-1995
13)
(1) The insulation resistance, between main cable dielectric cores and for main cores and grounding
wire, is not lower than 100M km when conversion into +20
(2) Transition resistance of main core screen layer is not over 3k when conversion into 20 .
(3) Product standard: MT818.5-1999.
(4) MYP type cable is consists of 3 main cores with main insulation screen and a grounding wire covered
with conductive rubber sheath, which is cabling and wrapped around the conductive rubber shaath
core, covered with yellow chlorinated PE rubber sheath or yellow neoprene from outside.
(5) Conductive core: adopting flexible Cu wire, the performance talies with GB/T3956-1997.
(6) Insulation: adopting XJ-00A type rubber in GB7594.2 1987.
(7) Wire core distinquishing: adopting insulation color separation distinquishing; main wire is red, white,
light blue, grounding wire is black.
(8) Grounding wire: adopting conductive rubber covered.
(9) Insulation screen: Wrapped conductive tape on insulation surface.
(10) Cabling: stranding into cable around conductive rubber sheath by right direction with 3 main wire
cores and 1 grounding wire.
(11) Sheath: adopting XH-03A type rubber in GB7594.7-1987. Oxygen index of sheath rubber is =40.
(12) Flame-retardant performance of finished product for MCP type satisfies the requirement of MT386
-1995.
(13) Cable sign: Model, voltage, specification and manufacturing works are printed on cable surface.
P67.
ELECTRIC WIRES & CABLE
Conductor
Rubber insulation
semiconducting filler
semiconducting screening
Rubber sheath
Notes
1) , +20 100M km
2) 20 3k
3) MT818.5-1999
4) MYP 3
5) GB/T3956-1997
6) GB7594.2-1987 XJ-00A
7)
8)
9)
10) 3 1
11) GB7594.7-1987 XH-03A 40
12) MT386-1995
13)
(1) The insulation resistance, between main cable dielectric cores and for main cores and grounding
wire, is not lower than 100M km when conversion into+20
(2) Transition resistance of main core screen layer is not over 3k when conversion into 20 .
(3) Product standard: MT818.5-1999.
(4) MYP type cable is consists of 3 main cores with main insulation screen and a grounding wire
covered with conductive rubber sheath, which is cabling and wrapped around the conductive rubber
shaath core, covered with black chlorinated PE rubber sheath or black neoprene from outside.
P68.
(5) Conductive core: adopting flexible Cu wire, the performance talies with GB/T3956-1997.
(6) Insulation: adopting XJ-00A type rubber in GB7594.2 1987.
(7) Wire core distinquishing: adopting insulation color separation distinquishing; main wire is red, white,
light blue.
(8) Grounding wire: adopting conductive rubber covered.
(9) Insulation screen: Wrapped conductive tape on insulation surface.
(10) Cabling: stranding into cable around conductive rubber sheath by right direction with 3 main wire
cores and 1 grounding wire.
(11) Sheath: adopting XH-03A type rubber in GB7594.7-1987. Oxygen index of sheath rubber is =40.
(12) Flame-retardant performance of finished product for MCP type satisfies the requirement of MT386-1995.
(13) Cable sign: Model, voltage, specification and manufacturing works are printed on cable surface.
Overall diameter ( ) 20
Nor.cross Insulation Sheath Current
sectional thickness thickness Ref. weight Max.D.C.resistance rating
min Max
areas mm2 mm mm kg/km of conductor (Cu) (20 )A
mm mm
in 20 /km
4.95
3 4+1 4 1.4 3.5 20.9 23 637 35
4.95
3.3
3 6+1 6 1.4 3.5 22.9 25.1 856 46
3.3
1.91
3 10+1 10 1.6 4 27.8 30.6 1304 64
1.91
1.21
3 16+1 10 1.6 4 30.3 33.3 1545 85
1.91
0.78
3 25+1 16 1.8 4.5 36.4 40.1 2269 113
1.21
0.554
3 35+1 16 1.8 4.5 40.5 44.6 2786 138
1.21
0.386
3 50+1 16 2 5 45.5 50.1 3554 173
1.21
0.272
3 70+1 25 2 5 51.5 55.1 4587 215
0.78
Conductor
Rubber insulation
filler
Rubber sheath
Notes
1) +20 100M km
2) MT818.5-1999
3) My 4 3
4) GB/T3956-1997
5) GB7594.2-1987 XJ-00A
6)
7)
P69.
ELECTRIC WIRES & CABLE
8) GB7594.7-1987 XH-03A 40
9) MT386-1995
10)
(1) The insulation resistance, between main cable dielectric cores and for main cores and grounding
wire, Is not lower than 100M km when conversion into +20
(2) Product standard: MT818.5-1999.
(3) MYP type cable has 4-core , which is consists of 3 main cores and a grounding wire, which is
cabling and wrapped around the conductive rubber sheath core, covered with black chlorinated
PE rubber sheath or black neoprene from outside.
(4) Conductive core: adopting flexible Cu wire, the performance talies with GB/T3956-1997.
(5) Insulation: adopting XJ-00A type rubber in GB7594.2 1987.
(6) Wire core indentify: adopting insulation color separation distinquishing; main wire is red, white,
light blue. Grounding wire is black.
(7) Cabling: Main wire core and grounding wire strand into cable around conductive rubber sheath by
right direction.
(8) Sheath: adopting XH-03A type rubber in GB7594.7-1987. Oxygen index of sheath rubber is =40.
(9) Flame-retardant performance of finished product for MCP type satisfies the requirement of MT386
-1995.
(10) Cable sign: Model, voltage, specification and manufacturing works are printed on cable surface.
1.2.9
Flexible metal screen rubber-sheathed cables for mining purposes
Type: MYPTJ Rated Voltage 3.6/6 kV
Overall diameter ( ) 20
Nor.cross Insulation Sheath Current
sectional thickness thickness Ref. weight Max.D.C.resistance rating
min Max
areas mm
2
mm mm kg/km of conductor (Cu) (20 )A
mm mm
in 20 /km
in out
0.795
3 25+3 16/3+3 2.5 4 2.5 5.0 57.5 63.0 6108 113
1.24
0.565
3 35+3 16/3+3 2.5 4 2.5 5.0 62.5 68.6 7200 138
1.24
0.393
3 50+3 25/3+3 2.5 4 2.5 5.5 64.9 71.4 8423 173
0.795
Notes:
1) , +20 100M km
2) MT818.6-1999
3) MYPTJ 3 3 3 3
4) GB/T3956-1997
5) GB7594.8-1987 XJ-30A
6)
7)
8) GB7594.67-1987 XJ-10A GB7594.7-1987 XH-03A
40
9) MT386-1995
10)
(1) The insulation resistance, between main cable dielectric cores and for main cores and grounding
wire, is not lower than 100M km when conversion into+20
(2) Product standard: MT818.6-1999.
(3) MYPTJ type cable has 3-core structure, which is consists of 3 main cores, 3 weaven grounding
wire core and 3 monitoring wire cores, which is cabling and wrapped around the sheath core,
covered with red chlorinated PE rubber sheath or red neoprene from outside.
(4) Conductive core: adopting flexible Cu wire, the performance talies with GB/T3956-1997.
(5) Insulation: adopting XJ-30A type rubber in GB7594.2 1987.
(6) Wire core indentify: adopting insulation color separation distinquishing; main wire is red, white, light
blue. Grounding wire is black.
(7) Cabling: Main wire core and grounding wire strand into cable around conductive rubber sheath
by right direction.
P70.
(8) Sheath: adopting XJ-10A type rubber in GB7594.67-1987 for sheath inside, XH-03A type rubber
in GB7594.7-1978 for sheath outside. Oxygen index of sheath rubber is =40.
(9) Flame-retartant performance of finished product for the cable be satified the requirement of MT386
-1995.
(10) Cable sign: Model, voltage, specification and manufacturing works are printed on cable surface.
2
XLPE Insulated Flame-retardant Power Cable for Mining Purpose
Executive standard
MT818.11 13-1999
The product is designed and manufactured according to MT818.11,13-1999 Flame-retardant
Cable for Mine .
2.1 Model and designation of product
Model Name
MYJV42
XLPE insulated thick st. wire armored PVC sheathed power cable for mining purpose
MYJV32
XLPE insulated thin st. Wire armored PVC sheathed power cable for mining purpose
MYJV22
XLPE insulated steel tape armored PVC sheathed power cable for mining purpose
MYJV
XLPE insulated PVC sheathed power cable for mining purpose
2.3
Working condition of cable
2.3.1 90
Long-term allowable working temperature of cable conductor is 90 .
2.3.2 ( 5 ) 250
Max. working temperature of cable conductor is not over 250 in short circuit (Max. lasting time
Is not over 5s).
2.4
XLPE insulated low voltage power cable for mining purpose
2.4.1
Construction and main technical data
2.4.1.1
XLPE insulated thick st. wire armored PVC sheathed power cable for mining purpose
P71.
ELECTRIC WIRES & CABLE
2.4.1.2
XLPE insulated thin st. Wire armored PVC sheathed power cable for mining purpose
Type MYJV32 Rated Voltage 0.6/1 kV
( ) 20
Nor.cross Insulation Sheath thickness Overall diameter Ref. weight Current
sectional thickness mm kg/km Max.D.C.resistance rating
areas mm of conductor (Cu) (20 )A
2
mm min Max in 20 /km
mm mm
3 4 0.7 1.8 15.3 19.3 587 4.61 35
3 6 0.7 1.8 16.4 20.4 696 3.08 45
3 10 0.7 1.8 19.3 23.3 939 1.83 63
3 16 0.7 1.8 21.4 25.4 1316 1.15 84
3 25 0.9 1.8 24.5 28.5 1766 0.727 113
3 35 0.9 1.9 26.8 30.8 2187 0.524 139
3 50 1.0 2.0 26.1 30.1 2402 0.387 161
3 70 1.1 2.0 29.6 33.6 3346 0.268 204
3 95 1.1 2.2 33.0 37.0 4268 0.193 252
3 120 1.2 2.4 36.3 40.3 5458 0.153 291
3 150 1.4 2.6 40.4 44.4 6546 0.124 333
3 185 1.6 2.7 44.2 48.2 7877 0.0991 385
3 240 1.7 2.9 49.5 53.5 9935 0.0754 457
3 300 1.8 3.1 54.5 58.5 11979 0.0601 527
P72.
2.4.1.3
XLPE insulated steel tape armored PVC sheathed power cable for mining purpose
Type MYJV22 Rated Voltage 0.6/1 kV
( ) 20
Nor.cross Insulation Sheath thickness Overall diameter Ref. weight Current
sectional thickness mm kg/km Max.D.C.resistance rating
areas mm of conductor (Cu) (20 )A
mm
2
min Max in 20 /km
mm mm
3 4 0.7 1.8 15.5 19.5 406 4.61 35
3 6 0.7 1.8 16.6 20.6 492 3.08 45
3 10 0.7 1.8 19.5 23.5 685 1.83 63
3 16 0.7 1.8 21.6 25.6 912 1.15 84
3 25 0.9 1.8 24.7 28.7 1301 0.727 113
3 35 0.9 1.8 26.8 30.8 1641 0.524 139
3 50 1.0 1.9 26.1 30.1 1867 0.387 161
3 70 1.1 2.0 31 35 2834 0.268 204
3 95 1.1 2.2 34.4 38.4 3681 0.193 252
3 120 1.2 2.3 37.5 41.5 4486 0.153 291
3 150 1.4 2.5 41.6 45.6 5477 0.124 333
3 185 1.6 2.6 45.4 49.4 6669 0.0991 385
3 240 1.7 2.8 50.7 54.7 8570 0.0754 457
3 300 1.8 3.0 55.7 59.7 10532 0.0601 527
2.4.1.4
XLPE insulated PVC sheathed power cable for mining purpose
Type MYJV Rated Voltage 0.6/1 kV
20
Nor.cross Insulation Sheath thickness Overall diameter Ref. weight Current
sectional thickness mm kg/km Max.D.C.resistance rating
areas mm of conductor (Cu) (20 )A
mm2 min Max in 20 /km
mm mm
3 1.5 0.7 1.8 10.4 14.4 209 12.1 20
3 2.5 0.7 1.8 11.2 15.2 254 7.41 27
3 4 0.7 1.8 12.3 16.3 319 4.61 35
3 6 0.7 1.8 13.4 17.4 397 3.08 45
3 10 0.7 1.8 16.3 20.3 570 1.83 63
3 16 0.7 1.8 18.4 22.4 782 1.15 84
3 25 0.9 1.8 21.5 25.5 1150 0.727 113
3 35 0.9 1.8 23.6 27.6 1475 0.524 139
3 50 1.0 1.9 22.9 26.9 1707 0.387 161
3 70 1.1 2.0 26.6 30.6 2361 0.268 204
3 95 1.1 2.1 29.8 33.8 3139 0.193 252
3 120 1.2 2.3 32.9 36.9 3907 0.153 291
3 150 1.4 2.4 36.8 40.8 4814 0.124 333
3 185 1.6 2.5 40.4 44.4 5940 0.0991 385
3 240 1.7 2.7 45.5 49.5 7751 0.0754 457
3 300 1.8 2.9 50.3 54.3 9629 0.0601 527
P73.
ELECTRIC WIRES & CABLE
2.5
XLPE insulated medium voltage power cable for mining purpose
2.5.1
XLPE insulated thick st. wire armored PVC sheathed power cable for mining purpose
Type MYJV42 Rated Voltage 8.7/10 kV
( ) 20
Nor.cross Insulation Sheath thickness Overall diameter Ref. weight Current
sectional thickness mm kg/km Max.D.C.resistance rating
areas mm min Max of conductor (Cu) (20 )A
mm
2
mm mm in 20 /km
2.5.2
XLPE insulated thin steel wire armored PVC sheathed power cable for mining purpose
Type MYJV32 Rated Voltage 8.7/10 kV
( ) 20
Nor.cross Insulation Sheath thickness Overall diameter Ref. weight Current
sectional thickness mm kg/km Max.D.C.resistance rating
areas mm min Max of conductor (Cu) (20 )A
mm2 mm mm in 20 /km
2.5.3
XLPE insulated steel tape PVC sheathed power cable for mining purpose
Type MYJV22 Rated Voltage 8.7/10 kV
20
Nor.cross Insulation Sheath thickness Overall diameter Ref. weight Current
sectional thickness mm kg/km Max.D.C.resistance rating
areas mm Max of conductor (Cu) (20 )A
2 min
mm mm mm in 20 /km
P74.
2.5.4
XLPE insulated PVC sheathed power cable for mining purpose
Type MYJV Rated Voltage 8.7/10 kV
20
Nor.cross Insulation Sheath thickness Overall diameter Ref. weight Current
sectional thickness mm kg/km Max.D.C.resistance rating
areas mm min Max of conductor (Cu) (20 )A
mm2 mm mm in 20 /km
MVV
PVC insulated PVC sherthed power cable for mining purpose
MVV22
PVC insulated steel tape armored PVC sheathed power cable for mining purpose
3.3
Working condition of cable
3.3.1
U0/U 0.6/1kV Rated voltage U0/U is 0.6/1kV.
3.3.2 70
Long-term allowable working temperature of cable conductor is 70 .
3.3.3 ( 5 ) 160
Max. working temperature of cable conductor is not over 160 in short circuit ( Max. lasting time
Is not over 5s).
3.3.4 0 , 2
Surrounding temperature shall not be lower than 0 in laying cable, Min.bending diameter is 2
times than cylinder diameter of cable bending test.
3.4
Construction and main technical data
3.4.1
PVC insulated PVC sheathed power cable for mining purpose
P75.
ELECTRIC WIRES & CABLE
( ) 20
Nor.cross Insulation Sheath thickness Overall diameter Ref. weight Current
sectional thickness mm kg/km Max.D.C.resistance rating
areas mm of conductor (Cu) (20 )A
min Max
mm2 mm in 20 /km
mm
3 1.5 0.8 1.8 10.9 14.9 165 12.1 13
3 2.5 0.8 1.8 11.7 15.7 206 7.41 20
3 4 1.0 1.8 13.6 17.6 290 4.61 30
3 6 1.0 1.8 14.7 18.7 367 3.08 37
3 10 1.0 1.8 17.6 21.6 536 1.83 53
3 16 1.0 1.8 19.7 23.7 745 1.15 69
3 25 1.2 1.8 22.8 26.8 1077 0.727 89
3 35 1.2 1.8 24.9 28.9 1390 0.524 109
3 50 1.4 1.8 24.6 28.6 1710 0.387 132
3 70 1.4 1.9 27.8 31.8 2342 0.268 167
3 95 1.6 2.1 32.1 36.1 3197 0.193 213
3 120 1.6 2.2 34.6 38.6 3916 0.153 242
3 150 1.8 2.3 38.5 42.5 4840 0.124 282
3 185 2.0 2.5 42.3 46.3 5991 0.0991 322
3 240 2.2 2.7 47.9 51.9 7851 0.0754 385
3 300 2.4 2.9 53.0 57.0 9770 0.0601 431
4 4-core
20
Nor.cross Insulation Sheath thickness Overall diameter Ref. weight Current
sectional thickness mm kg/km Max.D.C.resistance rating
areas mm Max of conductor (Cu) (20 )A
min
mm2 mm mm in 20 /km
P76.
3+1 3+1-core
( ) 20
Nor.cross Insulation Sheath Overall diameter Ref. weight Max.D.C.resistance Current
sectional thickness thickness kg/km of conductor (Cu) rating
areas mm mm in 20 /km (20 )A
mm2 min Max
mm mm
Large small Large small
3 4+1 2.5 1.0 0.8 1.8 14.4 18.4 333 4.61 7.41 30
3 6+1 4 1.0 1.0 1.8 15.6 19.6 428 3.08 4.61 37
3 10+1 6 1.0 1.0 1.8 18.9 22.9 628 1.83 3.08 53
3 16+1 10 1.0 1.0 1.8 21.3 25.3 883 1.15 1.83 69
3 25+1 16 1.2 1.0 1.8 24.4 28.4 1270 0.727 1.15 89
3 35+1 16 1.2 1.0 1.8 26.8 30.8 1598 0.524 1.15 109
3 50+1 25 1.4 1.2 1.0 30.8 34.8 2182 0.387 0.727 132
3 70+1 35 1.4 1.2 1.0 35.1 39.1 2978 0.268 0.524 167
3 95+1 50 1.6 1.4 1.0 40.6 44.6 4048 0.193 0.387 213
3 120+1 70 1.6 1.4 1.0 43.7 47.7 5003 0.153 0.268 242
3 150+1 70 1.8 1.4 1.0 48.7 52.7 6035 0.124 0.268 282
3 185+1 95 2.0 1.6 1.1 53.6 57.6 7543 0.0991 0.193 322
3 240+1 120 2.2 1.6 1.1 60.7 64.7 9796 0.0754 0.153 385
3 300+1 150 2.4 1.8 1.1 67.3 71.3 12172 0.0601 0.124 431
3.4.2
PVC insulated steel tape armored PVC sheathed power cable for mining purpose
( ) 20
Nor.cross Insulation Sheath thickness Overall diameter Ref. weight Max.D.C.resistance Current
sectional thickness mm kg/km of conductor (Cu) rating
areas mm in 20 /km (20 )A
min Max
mm2
mm mm
3 2.5 0.8 1.8 14.3 18.3 313 12.1 13
3 4 1.0 1.8 16.2 20.2 413 7.41 20
3 6 1.0 1.8 17.3 21.3 499 4.61 30
3 10 1.0 1.8 20.0 24.0 689 3.08 37
3 16 1.0 1.8 22.1 26.1 915 1.83 53
3 25 1.2 1.8 25.2 29.2 1273.3 1.15 69
3 35 1.2 1.8 27.3 31.3 1603.5 0.727 89
3 50 1.4 1.8 27.0 31.0 1920.4 0.524 109
3 70 1.4 1.8 30.2 34.2 2580.1 0.387 132
3 95 1.6 1.9 34.5 38.5 3497.9 0.268 167
3 120 1.6 2.1 38.2 42.2 4602 0.193 213
3 150 1.8 2.2 42.1 46.1 5602 0.153 242
3 185 2.0 2.3 45.7 49.7 6804.2 0.124 282
3 240 2.2 2.5 51.3 55.3 8770.2 0.0991 322
3 300 2.4 2.7 56.4 60.4 10787.1 0.0754 385
P77.
ELECTRIC WIRES & CABLE
4 4-core
( ) 20
Nor.cross Insulation Sheath thickness Overall diameter Ref. weight Current
sectional thickness mm kg/km Max.D.C.resistance rating
areas mm min Max of conductor (Cu) (20 )A
mm2 mm mm in 20 /km
3+1 3+1-core
( ) 20
Nor.cross Insulation Sheath Overall diameter Ref. weight Max.D.C.resistance Current
sectional thickness thickness kg/km of conductor (Cu) rating
areas mm mm in 20 /km (20 )A
mm2 min Max
mm mm
Large small Large small
3 4+1 2.5 1.0 0.8 1.8 17.0 21.0 462 4.61 7.41 30
3 6+1 4 1.0 1.0 1.8 18.2 22.2 567 3.08 4.61 37
3 10+1 6 1.0 1.0 1.8 21.3 25.3 792 1.83 3.08 53
3 16+1 10 1.0 1.0 1.8 23.7 27.7 1067 1.15 1.83 69
3 25+1 16 1.2 1.0 1.8 26.8 30.8 1480 0.727 1.15 89
3 35+1 16 1.2 1.0 1.8 29.4 33.4 1842 0.524 1.15 109
3 50+1 25 1.4 1.2 1.0 33.4 37.4 2460 0.387 0.727 132
3 70+1 35 1.4 1.2 1.0 37.7 41.7 3295 0.268 0.524 167
3 95+1 50 1.6 1.4 1.0 44.4 48.4 4873 0.193 0.387 213
3 120+1 70 1.6 1.4 1.0 47.5 51.5 5890 0.153 0.268 242
3 150+1 70 1.8 1.4 1.0 52.7 56.7 7048 0.124 0.268 282
3 185+1 95 2.0 1.6 1.1 57.4 61.4 8629 0.0991 0.193 322
3 240+1 120 2.2 1.6 1.1 64.5 68.5 11025 0.0754 0.153 385
3 300+1 150 2.4 1.8 1.1 71.3 75.3 13569 0.0601 0.124 431
The product is used as connection for electronic network and control system rated voltage 300/
500V and below, testing device and meters with high requirement on anti-jamming.
2 Technical Performance
2.1 50Hz 6h 50Hz 5min
1
Insulation wire core shall withstand AC 50Hz spark test, or drop in water of room temperature for
6h for AC 50Hz voltage test 5min. Testing voltage refers to table 1.
P78.
1 Table 1
Norminal insulation thickness mm Spark test voltage V Dropping in water test voltage V
0.3
4000
0.4 1500
0.5
0.6 6000
2000
0.7
2.4 2
DC resistance of cable and insulation resistance refer to table 2.
2 Table 2
20 Insulation resistance(M km)
Nor. Sectional area DC rsistance in 20
mm2 ( /km) Wire twist to conductors Wire twist to screens
0.5 36
1
0.75 24.5
1.0 18.1 PE insulated
PVC insulated
1.5 12.1 5000
10
2.5 7.41
3
Cable model, desgination and manufacturing scope refer
3 Table 3
DJYVP2
PE insulated stranded group Cu tape screen PVC sheathed cable for computer
DJYVP3
PE insulated stranded group Al compound tape screen PVC sheathed cable for computer
DJYPV
PE insulated stranded group Cu twisting sub-screen PVC sheathed cable for computer
DJYP2V
PE insulated stranded group Cu tape sub-screen PVC sheathed cable for computer
DJYP3V
PE insulated stranded group Al compound tape sub-screen PVC sheathed cable for computer
DJYPVP
PE insulated stranded group Cu twisting sub-screen & general screen PVC sheathed cable for computer
DJYP2VP2
PE insulated stranded group Cu tape sub-screen & general screen PVC sheathed cable for computer
DJYP3VP3
PE insulated stranded group Al compound tape sub-screen & general screen PVC sheathed cable for computer
P79.
ELECTRIC WIRES & CABLE
DJYVP3R
PE insulated stranded group Al compound tape screen PVC sheathed flexible cable for computer
DJYPVR
PE insulated stranded group Cu twisting sub-screen PVC sheathed flexible cable for computer
DJYP2VR
PE insulated stranded group Cu tape sub-screen PVC sheathed flexible cable for computer
DJYP3VR
PE insulated stranded group Al compound tape sub-screen PVC sheathed flexible cable for computer
DJYPVPR
PE insulated stranded group Cu twisting sub-screen & general screen PVC sheathed flexible cable for computer
DJYP2VP2R
PE insulated stranded group Cu tape sub-screen & general screen PVC sheathed flexible cable for computer
DJYP3VP3R
PE insulated stranded group Al compound tape sub-screen & general screen PVC sheathed flexible cable for computer
DJYVP22
PE insulated stranded group Cu twisting screen steel tape armored PVC sheathed cable for computer
DJYVP222
PE insulated stranded group Cu tape screen steel tape armored PVC sheathed cable for computer
DJYVP322
PE insulated stranded group Al compound tape screen steel tape armored screen PVC sheathed cable for computer
DJYPVP22
PE insulated stranded group Cu twisting sub-screen & general screen steel tape PVC sheathed cable for computer
DJYP2VP222
PE insulated stranded group Cu tape sub-screen & general screen steel tape armored PVC sheathed cable for computer
DJYP3VP322 PE insulated stranded group Al compound tape sub-screen & general screen steel tape
armored PVC sheathed cable for computer
DJYPV22
PE insulated stranded group Cu wire twisting sub-screen steel tape armored PVC sheathed cable for computer
DJYP2V22
PE insulated stranded group Cu tape sub-screen steel tape armored PVC sheathed cable for computer
DJYP3V22
PE insulated stranded group Al compound tape sub-screen PVC sheathed cable for computer
P80.