Power Produced: Temperature TH

The document contains data from three experiments measuring the efficiency and power output of a thermodynamic system as the temperature increases. It provides temperature in Kelvin (TH) and (TL), efficiency, power output in kW, and groups the data into experiments where TL was set to 0°C, 25°C, and 50°C. The efficiency increases and power output decreases as TH increases for each TL setting. A line graph compares the power output versus temperature for each TL, and another line graph shows how efficiency decreases with higher temperatures for each TL setting.

Uploaded by

XheikhKaleem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
32 views2 pages

Power Produced: Temperature TH

The document contains data from three experiments measuring the efficiency and power output of a thermodynamic system as the temperature increases. It provides temperature in Kelvin (TH) and (TL), efficiency, power output in kW, and groups the data into experiments where TL was set to 0°C, 25°C, and 50°C. The efficiency increases and power output decreases as TH increases for each TL setting. A line graph compares the power output versus temperature for each TL, and another line graph shows how efficiency decreases with higher temperatures for each TL setting.

Uploaded by

XheikhKaleem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

TH TL TH TL efficiency Q

C C K K KW
300 0 573.15 273.15 0.523423 567.0418 900
400 673.15 0.594221 643.7396 850
800
500 773.15 0.646705 700.5971 750
600 873.15 0.687167 744.4311

Power kW
700
700 973.15 0.719314 779.2564 650
600
800 1073.15 0.745469 807.5914 550
900 1173.15 0.767165 831.0958 500
1000 1273.15 0.785453 850.9079 450
400
500 600
TH TL TH TL efficiency Q
C C K K KW
300 25 573.15 298.15 0.479805 519.7883
400 673.15 0.557082 603.5059
500 773.15 0.61437 665.5673
600 873.15 0.658535 713.4131
700 973.15 0.693624 751.4258
800 1073.15 0.722173 782.3541
900 1173.15 0.745855 808.0098
1000 1273.15 0.765817 829.6352
Effi
TH TL TH TL efficiency Q
1
C C K K KW
300 50 573.15 323.15 0.436186 472.5348
0.8
400 673.15 0.519944 563.2722
500 773.15 0.582035 630.5374 0.6
Efficeincy

600 873.15 0.629903 682.3952


700 973.15 0.667934 723.5952 0.4
800 1073.15 0.698877 757.1169
0.2
900 1173.15 0.724545 784.9238
1000 1273.15 0.746181 808.3625
0
500 600 700 800 90
Temperat
Power produced
900
850
800
750
Power kW

700
650
600
550
500
450
400
500 600 700 800 900 1000 1100 1200 1300
Temperature TH

TL = 0 C TL = 25 C TL = 50 C

Efficiency
1

0.8

0.6 TL = 0 C
TL = 25 C
0.4 TL = 50 C

0.2

0
500 600 700 800 900 1000 1100 1200 1300
Temperature TH